FACILITY NAME Mallinckrodt LLC COUNTY Wake County
PERSON COLLECTING SAMPLES Claudia Irvin — S&ME. Inc. PHONE NO. (919) 872-2660
CERTIFIED LABORATORY ESC Lab Sciences Lab # ENV375
Lab # PLEASE SIGN ON THE REVERSE 4
Part B: Specific Monitoring Requirements
Outfall
No.
Date
Sample
Collected,
mo/dd/ r
Total
Suspended
Solids, mg/L
pH,
Standard
units
Conductivity,
us/cm
Chemical
Oxygen
Demand,
mgfL
Total
Nitrogen,
mg/L
Nitrate-
Nitrite,
mg/L
Ammonia
Nitrogen,
mg/L
Sulfate,
mg/L
Ammonium
Sulfate, mg/L
(calculated
result
Benchmark
-
100
6.0-9.0
NA
120
30
10
7.2
500
19
Outfall 001
05/21/2015
26
6.4
77
35
3.1
1.1
0.58
<5.0
<0.5
Outfall 002
05/21/2015
46
6.5
198
53
5.8
1.7
2
13
9.43
Outfall 003B
05/21/2015
29
7.9
448
30
2.4
<0.1
<0.25
64
< 0.25
Note: If you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Tier 1 or Tier 2 responses.
Did this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? _yes X no
(if yes, complete Part B)
Part D: Vehicle Maintenance Activity Monitoring Requirements
Outfall
No.
Date
Sample Collected,
mo/dd/ r
00556
Oil and Grease,
mg/L
00530
Total Suspended Solids,
m
00400
pH, New Motor Oil Usage,
Standard units Annual averse al/mo
Benchmark
-
15
100
6.0-9.0 -
NA
NA
NA
NA
NA NA
Note: If you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Tier 1 or Tier 2 responses.
See General Permit text. �EF Ce j,ED
STORM EVENT CHARACTERISTICS: Mail Original and one copy to: JUN ? 0 2�
Division of Water Quality 15
Date 5/21/2015 (first event sampled) Attn: DWQ Central Files ST ')E'VR-(qND
Total Event Precipitation (inches): 0.24 1617 hallorth is Lena 27699-1617 ORMWATERP UALRaleNG
Date (list each additional event sampled this reporting period, and rainfall amount)
Total Event Precipitation (inches):
SWU-245-031308
Page 1 of 2
1 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or
manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject
to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for
electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31).
Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring maybe waived. The
solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the
TTO monitoring waiver, the discharger shall sign the following certification statement:
"Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I
certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater
runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management
plan included in the Stormwater Pollution Prevention Plan."
NA
Name (Print name)
NA
Title (Print title)
NA NA
(Signature) (Date)
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or
supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the
information submitted. Based on my inquiry of the person or persons who manage the system, or those persons
directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief,
true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including
the possibility of fines and imprisonment for knowing violations."
D
(Signature of Permittee)
(Date)
SNNU-245-031308
Page 2 of 2