Loading...
HomeMy WebLinkAboutWQCS00089_BIMS Report_20240426 Compliance Inspection Report Permit:WQCS00089 Effective: 09/01/16 Expiration: 08/31/24 Owner: City of Cherryville SOC: Effective: Expiration: Facility: Cherryville Collection System County: Gaston 115 S Mtn St Region: Mooresville Cherryville NC 280213421 Contact Person:Robert Kevin Abernathy Title: Water&Sewer Super Phone: 704-435-1737 Directions to Facility: System Classifications: CS2, Primary ORC: Jason Timothy Stone Certification: 1008988 Phone: 704-740-0230 Secondary ORC(s): On-Site Representative(s): Related Permits: NC0044440 City of Cherryville-Cherryville WWTP Inspection Date: 04/25/2024 Entry Time 10:OOAM Exit Time: 02:OOPM Primary Inspector:Tony Parker Phone: 704-663-1699 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Collection system management and operation Facility Status: Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions General Sewer& FOG Ordinances Capital Improvement Plan Map Reporting Requirements Inspections Spill Response Plan Spills Lines Manholes Pump Stations (See attachment summary) Page 1 of 7 Permit: WQCS00089 Owner-Facility:City of Cherryville Inspection Date: 04/25/2024 Inspection Type:Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: Page 2 of 7 Permit: WQCS00089 Owner-Facility:City of Cherryville Inspection Date: 04/25/2024 Inspection Type:Collection System Inspect Non Sampling Reason for Visit: Routine General Yes No NA NE Is there a properly designated primary ORC and at least one back-up of proper grade? 0 ❑ ❑ ❑ Are logs being reviewed by the system management or owner on a regular basis? 0 ❑ ❑ ❑ #What is that frequency? monthly #Are there any issues being addressed currently or any in the planning stages? 0 ❑ ❑ ❑ Is there a specific pump failure plan available for all pump stations? 0 ❑ ❑ ❑ Does plan indicate if pump parts/new pumps are in spare parts/equipment inventory? 0 ❑ ❑ ❑ Are new/significantly upgraded pump stations equipped with anti-corrosion materials? 0 ❑ ❑ ❑ Does the permittee have a copy of their permit? 0 ❑ ❑ ❑ # Is permit expiring within the next 6 months? 0 ❑ ❑ ❑ If Yes, has the Permittee applied for renewal? 0 ❑ ❑ ❑ Comment: The current permit expires 8/31/2024. A permit renewal application has been submitted as required. Sewer and FOG Ordinances Yes No NA NE Is Sewer Use Ordinance(SUO)or other Legal Authority available? 0 ❑ ❑ ❑ Does it appear that the Sewer Use Ordinance is enforced? 0 ❑ ❑ ❑ Is there a Grease Control Program that legally requires grease control devices? 0 ❑ ❑ ❑ What is the standard grease trap cleaning requirement in the FOG ordinance? variable Is Grease Control Program enforced via periodic inspections/records review? 0 ❑ ❑ ❑ Is action taken against violators? 0 ❑ ❑ ❑ #Have satellite systems adopted an equivalent or more stringent ordinance? ❑ ❑ 0 ❑ Is grease/sewer education program documented with req'd customer distribution? 0 ❑ ❑ ❑ #Are other types of education tools used like websites, booths, special meetings, etc? 0 ❑ ❑ ❑ If Yes,what are they?(This can reduce mailing to annual.) The city uses social media,website, mailouts for FOG info distribution and posts info at city offices. Comment: Capital Improvement Plan Yes No NA NE Has a Capital (CIP)or System Improvement Plan been developed and adopted? ❑ ❑ ❑ Is it designated for wastewater only or does it have a dedicated section? ❑ ❑ ❑ Does CIP cover three to five year period of earmarked improvements? ❑ ❑ ❑ Does CIP include description of project area? ❑ ❑ ❑ Does CIP include description of existing facilities? ❑ ❑ ❑ Does CIP include known deficiencies? ❑ ❑ ❑ Does CIP include forecasted future needs? 0 ❑ ❑ ❑ Comment: The city has extensive on going capital improvement plans to up grade their collection system and funding appears to be adequate for future needs at this time. Page 3 of 7 Permit: WQCS00089 Owner-Facility:City of Cherryville Inspection Date: 04/25/2024 Inspection Type:Collection System Inspect Non Sampling Reason for Visit: Routine Map Yes No NA NE Is there a overall sewer system map? 0 ❑ ❑ ❑ Does the map include: Pipe Type(GS/FM) 0 ❑ ❑ ❑ Pipe sizes 0 ❑ ❑ ❑ Pipe materials(PVC, DIP, etc) 0 ❑ ❑ ❑ Pipe location 0 ❑ ❑ ❑ Flow direction 0 ❑ ❑ ❑ Approximate pipe age 0 ❑ ❑ ❑ Pump station ID, location and capacity 0 ❑ ❑ ❑ # Force main air release valve location &type 0 ❑ ❑ ❑ # Location of satellite connections ❑ ❑ 0 ❑ Is the map being updated for changes/additions within 1 year of activation? 0 ❑ ❑ ❑ Comment: The city uses detailed paper maps. Reporting Requirements Yes No NA NE #Have there been any sewer spills in the past 3 years? ❑ ❑ ❑ If Yes,were they reported to the Division if meeting the reportable criteria? ❑ ❑ ❑ If applicable, is there documentation of press releases and public notices issued? ❑ ❑ ❑ Is an Annual Wastewater Performance Report being filed with the Division, if required? ❑ ❑ ❑ Is the report being made available to all its sewer customers? ❑ ❑ ❑ #How is it being made available? website Comment: The city is not free of spills or SSO's but are responding, reporting & documenting as required. Inspections Yes No NA NE Are adequate maintenance records maintained? ❑ ❑ ❑ Are pump stations being inspected at the required frequency? ❑ ❑ ❑ # Is at least one complete functionality test conducted weekly per pump station? ❑ ❑ ❑ Is there a system or plan in place to observe the entire system annually? ❑ ❑ ❑ Is the annual inspection documented? ❑ ❑ ❑ #Does the system have any high-priority lines/locations? ❑ ❑ ❑ Are inspections of HPL documented at least every 6 months? ❑ ❑ ❑ Are new lines being added to the HPL list when found or created? 0 ❑ ❑ ❑ Comment: All activities were well documented. Spill Response Action Plan Yes No NA NE Is a Spill Response Action Plan available? 0 ❑ ❑ ❑ Is a Spill Response Action Plan available for all personnel? 0 ❑ ❑ ❑ Page 4 of 7 Permit: WQCS00089 Owner-Facility:City of Cherryville Inspection Date: 04/25/2024 Inspection Type:Collection System Inspect Non Sampling Reason for Visit: Routine Does the plan include: 24-hour contact numbers ❑ ❑ ❑ Response time ❑ ❑ ❑ Equipment list and spare parts inventory ❑ ❑ ❑ Access to cleaning equipment ❑ ❑ ❑ Access to construction crews, contractors, and/or engineers ❑ ❑ ❑ Source of emergency funds ❑ ❑ ❑ Site sanitation and cleanup materials ❑ ❑ ❑ Post-overflow/spill assessment ❑ ❑ ❑ Does the Permittee appear to respond within 2 hours of first knowledge of a spill? 0 ❑ ❑ ❑ Comment: A spill response plan was available. $pills Yes No NA NE Is system free of known points of bypass? ❑ ❑ ❑ If No, describe type of bypass and location Are all spills or sewer related issues/complaints documented? ❑ ❑ ❑ #Are there repeated overflows/problems(2 or more in 12 months)at same location? ❑ ❑ ❑ # If Yes, is there a corrective action plan? ❑ ❑ 0 ❑ Comment: Lines/Right-of-Ways/Aerial Lines Yes No NA NE Please list the Lines/Right of Ways/Aerial Lines Inspected: West Carroll Street outfall&aerial. No issues with the aerial crossing or support structure&outfall was clear. Are right-of-ways/easements maintained for full width for access by staff/equipment? ❑ ❑ ❑ If No, give details on temporary access: Is maintenance documented? ❑ ❑ ❑ Are gravity sewer cleaning records available? ❑ ❑ ❑ Has at least 10%of lines older than 5 yrs been cleaned annually? ❑ ❑ ❑ Were all areas/lines inspected free of issues? 0 ❑ ❑ ❑ Comment: All activities were well documented and the city exceeded the minimum 10% line cleaning requirement. Manholes Yes No NA NE Please list the Manholes Inspected: Various manholes inspected and several issues noted as follows; Two manholes on West Carroll Street outfall at Power Sub Station needs rehab. No other major manhole issues noted. Are manholes accessible? ❑ ❑ ❑ #Are manhole covers/vents above grade? ❑ ❑ ❑ Are manholes free of visible signs of overflow? ❑ ❑ ❑ Are manholes free of sinkholes and depressions? 0 ❑ ❑ ❑ Page 5 of 7 Permit: WQCS00089 Owner-Facility:City of Cherryville Inspection Date: 04/25/2024 Inspection Type:Collection System Inspect Non Sampling Reason for Visit: Routine Are manhole covers present? 0 ❑ ❑ ❑ #Are manholes properly seated? 0 ❑ ❑ ❑ #Are manholes in good condition? 0 ❑ ❑ ❑ #Are inverts in good condition? 0 ❑ ❑ ❑ Is flow unrestricted in manholes? 0 ❑ ❑ ❑ Are manholes free of excessive amounts of grease? 0 ❑ ❑ ❑ Are manholes free of excessive roots? 0 ❑ ❑ ❑ Are manholes free of excessive sand? 0 ❑ ❑ ❑ Are manhole vents screened? ❑ ❑ ❑ Are vents free of submergence? ❑ ❑ ❑ Are manholes free of bypass structures or pipes? 0 ❑ ❑ ❑ Comment: No vented manholes were observed during this inspection. Pump Stations Yes No NA NE Please list the Pump Stations Inspected: Stonewood Estates P/S#2,Tot Dellinger P/S#4, Country Club P/S&Main influent P/S. Capital Improvement upgrades are currently planned for all 10 pump stations. Funding has been approved and a request for bids will be sent out soon. #Number of duplex or larger pump stations in system 10 #Number of vacuum stations in system 0 #Number of simplex pump stations in system 1 #Number of simplex pump stations in system serving more than one building 0 How many pump/vacuum stations have: # A two-way"auto polling"communication system (SCADA)installed? 5 # A simple one-way telemetry/communication system (auto-dialer)installed? 5 For pump stations inspected: Are they secure with restricted access? ❑ ❑ ❑ Were they free of by-pass structures/pipes? ❑ ❑ ❑ Were wet wells free of excessive grease/debris? ❑ ❑ ❑ # Do they all have telemetry installed? ❑ ❑ ❑ Is the communication system functional? ❑ ❑ ❑ Is a 24-hour notification sign posted ? ❑ ❑ ❑ Does the sign include: Owner Name? ❑ ❑ ❑ Pump station identifier? ❑ ❑ ❑ # Address? ❑ ❑ ❑ Instructions for notification? ❑ ❑ ❑ 24-hour emergency contact numbers? 0 ❑ ❑ ❑ Page 6 of 7 Permit: WQCS00089 Owner-Facility:City of Cherryville Inspection Date: 04/25/2024 Inspection Type:Collection System Inspect Non Sampling Reason for Visit: Routine Are audio and visual alarms present? 0 ❑ ❑ ❑ Are audio and visual alarms operable? 0 ❑ ❑ ❑ # Is there a backup generator or bypass pump connected? 0 ❑ ❑ ❑ If tested during inspection, did it function properly? 0 ❑ ❑ ❑ Is the back-up system tested at least bi-annually under normal operating conditions? 0 ❑ ❑ ❑ #Does it have a dedicated connection for a portable generator? 0 ❑ ❑ ❑ # Is the owner relying on portable units in the event of a power outage? ❑ ❑ 0 ❑ # If Yes, is there a distribution plan? ❑ ❑ 0 ❑ If Yes,what resources (Units/Staff/Vehicles/etc)are included in Plan? The City has 4 on-stie dedicated generators 1 by-pass pump available. More generators are planned during the collection system improvements. #Does Permittee have the approved percentage of replacement simplex pumps? 0 ❑ ❑ ❑ Is recordkeeping of pump station inspection and maintenance program adequate? 0 ❑ ❑ ❑ Do pump station logs include at a minimum: Inside and outside cleaning and debris removal? 0 ❑ ❑ ❑ Inspecting and exercising all valves? 0 ❑ ❑ ❑ Inspecting and lubricating pumps and other equipment? 0 ❑ ❑ ❑ Inspecting alarms,telemetry and auxiliary equipment? 0 ❑ ❑ ❑ Comment: Pump Stations for the most part appeared to be adequately operated and maintained. The planned capital improvement upgrades will greatly enhance the overall operation. Page 7 of 7