Loading...
HomeMy WebLinkAboutWQCS00168_Notice of Violation-NOV-2024-PC-0233_20240417ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director NORTH CAROLINA Environmental Quality Certified Mail # 7022-2410-0002-5119-6116 Return Receipt Requested April 17, 2024 Bill Hudson, Mayor Town of Star PO Box 97 Star, NC 27356 SUBJECT: NOTICE OF VIOLATION Tracking Number: NOV-2024-PC-0233 Permit No. WQCS00168 Star Collection System Montgomery County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Star Collection System on April 4, 2024. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Collection System Permit No. WQCS00168. A summary of the findings and comments noted during the inspection are provided in the enclosed copy of the inspection report. The Collection System Non -sampling inspection was conducted by Division of Water Resources staff from the Fayetteville Regional Office. The following violation(s) were noted during the inspection: Inspection Area Description of Violation Pump Stations All duplex pump stations have only one operable pump. This does not meet permit requirement as stated in Section I.7. of the permit "... If one of the pumps in a pump station containing multiple pumps fails, the process of repairing or replacing the pump shall be initiated immediately and the new parts or pump shall be installed as soon as possible.... [15A NCAC 02T.0305 (h) (1)] " Da Q > North Carolina Department of Environmental Quality I Division of Water Resources Fayetteville Regional Office 1 225 Green Street, Suite 714 1 Fayetteville, North Carolina 28301 o.n.mMmme.om.ma n 910.433.3300 Inspection Area Description of Violation Sewer and FOG Ordinances Grease education materials have only been distributed once a year at the most. This does not meet the requirement as stated in permit section I. 4. "The Permittee shall develop and implement an educational fats, oils and grease program that shall include at least semiannual distribution of educational material targeted at both residential and non-residential users.... [15A NCAC 02T.0108 (b)] " Pump Stations Permittee does not know how to test alarms at seven of the eight pump stations and is not testing alarms as required in Permit section II. 4 "The Permittee shall develop and implement a routine pump station inspection and maintenance program which shall include the following maintenance activities: a. Cleaning and removing debris from the pump station structure, outside perimeter, and wet Well; b. Inspecting and exercising all valves; c. Inspecting and lubricating pumps and other mechanical equipment; and d.Verifying the proper operation of the alarms, telemetry system and auxiliary equipment. [15A NCAC 02T.0108(b)] " Remedial actions should have already been taken to correct this problem and prevent further occurrences in the future. The Division of Water Resources may pursue enforcement action for this and any additional violations of State law. To prevent further action, please respond in writing to this office within 30 days upon your receipt of this Notice of Violation regarding your plans or measures to be taken to address the indicated violations and other identified issues, if applicable. Da Q > North Carolina Department of Environmental Quality I Division of Water Resources Fayetteville Regional Office 1 225 Green Street, Suite 714 1 Fayetteville, North Carolina 28301 o.n.mMmme.om.ma n 910.433.3300 If you should have any questions, please do not hesitate to contact Kirsten Steininger with the Water Quality Regional Operations Section in the Fayetteville Regional Office at 910-433-3339. Ec: Laserfiche Sincerely, DocuSigned by: 6 4/23/2024 E4E1A9691DB248E... Mark Brantley, Regional Supervisor Water Quality Regional Operations Section Fayetteville Regional Office Division of Water Resources, NCDEQ D_E Q-� North Carolina Department of Environmental Quality I Division of Water Resources Fayetteville Regional Office 1 225 Green Street, Suite 714 1 Fayetteville, North Carolina 28301 iaemmm�� 910.433.3300 Compliance Inspection Report Permit: WQCS00168 Effective: 06/04/18 Expiration: 03/31/26 Owner : Town of Star SOC: Effective: Expiration: Facility: Star Collection System County: Montgomery PO Box 97 Region: Fayetteville Contact Person: James Wesley Brown Title: Phone: 910-428-4523 Directions to Facility: System Classifications: CS1, Primary ORC: James Wesley Brown Certification: 14480 Phone: 910-428-4623 Secondary ORC(s): On -Site Representative(s): Related Permits: NC0058548 Town of Star - Star WWTP Inspection Date: 04/04/2024 Entry Time 10:45AM Exit Time: 12:30PM Primary Inspector: Kirsten Steininger Cy gtU "' 4/16/2024 Phone: 910-433-3324 A4fiD6fiFEA3AFdEE_. Secondary Inspectors): oocusiyned by- 4/2 3/2024 Reason for Inspection: Routine E4E,A9691DB248E. Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Collection system management and operation Facility Status: ❑ Compliant Not Compliant Question Areas: Miscellaneous Questions General Sewer & FOG Ordinances Capital Improvement Plan Map Reporting Requirements Inspections Spill Response Plan Spills Lines Manholes Pump Stations (See attachment summary) Page 1 of 7 Permit: WQCS00168 Owner - Facility: Town of Star Inspection Date: 04/04/2024 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: During the inspection it was found that there are gaps in required paperwork and continued issues with pump stations not meeting permit requirements. Paperwork The 10% gravity sewer cleaning requirement was met. The required paperwork and records were available and met the requirements, with a few exceptions. The last annual report was made in 2023, but permittee did not report to division or make available to customers. The online map crashed, so currently only maps from 1924 are available. The CIP goes through 2024 and needs to be updated before the next inspection. Grease education is only sent out once a year or less, which does not meet permit requirements. This was mentioned in the inspection report from 2022, but has not been addressed. Field Inspections Pump stations 2, 6, 7, and 8 were inspected. At the time of the inspection, all pump stations were secure with proper signage and all wet wells were clear of excess debris. Only one alarm was tested during the inspection and it was working at that time. The permittee does not know how to test the other alarms, which are transducers. The permittee needs to find out how the alarms can be tested to verify that they are operable. This was mentioned in the 2022 inspection report and has not been addressed. All the pump stations have only one working pump even though the pump stations are duplex. This issue was also noted in the 2022 inspection report, for at least one pump station, and has not been addressed. The manhole at Cotton Creek road school was viewed and was in good condition at the time of the inspection. The ROWs at Brewer st & Dameron St were viewed during the inspection and were accessible for maintenance at that time. The ROW at Dameron St was starting to have overgrowth of vegetation, but still appeared to be accessible. Page 2 of 7 Permit: WQCS00168 Owner - Facility: Town of Star Inspection Date: 04/04/2024 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine General Yes No NA NE Is there a properly designated primary ORC and at least one back-up of proper grade? ❑ ❑ ❑ Are logs being reviewed by the system management or owner on a regular basis? ❑ ❑ ❑ # What is that frequency? NE # Are there any issues being addressed currently or any in the planning stages? 0 ❑ ❑ ❑ Is there a specific pump failure plan available for all pump stations? ❑ ❑ ❑ Does plan indicate if pump parts/new pumps are in spare parts/equipment inventory? ❑ ❑ ❑ Are new/significantly upgraded pump stations equipped with anti -corrosion materials? ❑ ❑ ❑ Does the permittee have a copy of their permit? ❑ ❑ ❑ # Is permit expiring within the next 6 months? ❑ ❑ ❑ If Yes, has the Permittee applied for renewal? ❑ ❑ ❑ Comment: Grants awarded for improvements; waitinq to receive the funds; plan for use of funds is to at least upgrade pump stations; spare pumps inventory & septic tank hauler available for pump failure/power outage Sewer and FOG Ordinances Yes No NA NE Is Sewer Use Ordinance (SUO) or other Legal Authority available? 0 ❑ ❑ ❑ Does it appear that the Sewer Use Ordinance is enforced? 0 ❑ ❑ ❑ Is there a Grease Control Program that legally requires grease control devices? 0 ❑ ❑ ❑ What is the standard grease trap cleaning requirement in the FOG ordinance? every 30 days Is Grease Control Program enforced via periodic inspections/records review? ❑ ❑ ❑ Is action taken against violators? ❑ ❑ 0 ❑ # Have satellite systems adopted an equivalent or more stringent ordinance? ❑ ❑ 0 ❑ Is grease/sewer education program documented with req'd customer distribution? ❑ 0 ❑ ❑ # Are other types of education tools used like websites, booths, special meetings, etc? ❑ ❑ 0 ❑ If Yes, what are they? (This can reduce mailing to annual.) Comment: Statement advising agains pouring grease into drains is distributed about once a year Capital Improvement Plan Yes No NA NE Has a Capital (CIP) or System Improvement Plan been developed and adopted? 0 ❑ ❑ ❑ Is it designated for wastewater only or does it have a dedicated section? 0 ❑ ❑ ❑ Does CIP cover three to five year period of earmarked improvements? ❑ ❑ ❑ Does CIP include description of project area? ❑ ❑ ❑ Does CIP include description of existing facilities? ❑ ❑ ❑ Does CIP include known deficiencies? ❑ ❑ ❑ Does CIP include forecasted future needs? 0 ❑ ❑ ❑ Comment: CIP through 2024, needs to be updated before next inspection Page 3 of 7 Permit: WQCS00168 Owner - Facility: Town of Star Inspection Date: 04/04/2024 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Map Yes No NA NE Is there a overall sewer system map? 0 ❑ ❑ ❑ Does the map include: Pipe Type (GS/FM) ❑ ❑ ❑ Pipe sizes ❑ ❑ ❑ Pipe materials (PVC, DIP, etc) ❑ ❑ ❑ Pipe location ❑ ❑ ❑ Flow direction ❑ ❑ ❑ Approximate pipe age ❑ ❑ ❑ Pump station ID, location and capacity ❑ ❑ ❑ # Force main air release valve location & type ❑ ❑ ❑ # Location of satellite connections ❑ ❑ 0 ❑ Is the map being updated for changes/additions within 1 year of activation? 0 ❑ ❑ ❑ Comment: online map crashed, using 1924 maps until engineers make new map Reporting Requirements Yes No NA NE # Have there been any sewer spills in the past 3 years? ❑ ❑ ❑ If Yes, were they reported to the Division if meeting the reportable criteria? ❑ ❑ ❑ If applicable, is there documentation of press releases and public notices issued? ❑ ❑ ❑ Is an Annual Wastewater Performance Report being filed with the Division, if required? ❑ ❑ ❑ Is the report being made available to all its sewer customers? ❑ ❑ ❑ # How is it being made available? NA Comment: Last annual report was made in 2023, but permittee did not report to division or make available to customers Inspections Yes No NA NE Are adequate maintenance records maintained? 0 ❑ ❑ ❑ Are pump stations being inspected at the required frequency? ❑ ❑ ❑ # Is at least one complete functionality test conducted weekly per pump station? ❑ ❑ ❑ Is there a system or plan in place to observe the entire system annually? ❑ ❑ ❑ Is the annual inspection documented? ❑ ❑ ❑ # Does the system have any high -priority lines/locations? ❑ ❑ ❑ Are inspections of HPL documented at least every 6 months? ❑ ❑ ❑ Are new lines being added to the HPL list when found or created? ❑ ❑ ❑ Comment: HPL at park from East bank street to Monroe street Spill Response Action Plan Yes No NA NE Is a Spill Response Action Plan available? 0 ❑ ❑ ❑ Is a Spill Response Action Plan available for all personnel? 0 ❑ ❑ ❑ Page 4 of 7 Permit: WQCS00168 Owner - Facility: Town of Star Inspection Date: 04/04/2024 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Does the plan include: 24-hour contact numbers ❑ ❑ ❑ Response time ❑ ❑ ❑ Equipment list and spare parts inventory ❑ ❑ ❑ Access to cleaning equipment ❑ ❑ ❑ Access to construction crews, contractors, and/or engineers ❑ ❑ ❑ Source of emergency funds ❑ ❑ ❑ Site sanitation and cleanup materials ❑ ❑ ❑ Post-overflow/spill assessment ❑ ❑ ❑ Does the Permittee appear to respond within 2 hours of first knowledge of a spill? 0 ❑ ❑ ❑ Comment: $pills Yes No NA NE Is system free of known points of bypass? ❑ ❑ ❑ If No, describe type of bypass and location Are all spills or sewer related issues/complaints documented? ❑ ❑ ❑ # Are there repeated overflows/problems (2 or more in 12 months) at same location? ❑ ❑ ❑ # If Yes, is there a corrective action plan? ❑ ❑ 0 ❑ Comment: complaints not documented, but orc addresses complaints in person and some information is recorded in other records Lines/Right-of-Ways/Aerial Lines Please list the Lines/Right of Ways/Aerial Lines Inspected: ROWs at Brewer st & Dameron St Yes No NA NE Are right-of-ways/easements maintained for full width for access by staff/equipment? ❑ ❑ ❑ If No, give details on temporary access: Is maintenance documented? ❑ ❑ ❑ Are gravity sewer cleaning records available? ❑ ❑ ❑ Has at least 10% of lines older than 5 yrs been cleaned annually? ❑ ❑ ❑ Were all areas/lines inspected free of issues? 0 ❑ ❑ ❑ Comment: annual cleaning requirement — 2,640ft; 10% requirement well surpassed; The ROWS at Brewer st & Dameron St were viewed during the inspection and were accessible for maintenance at that time. The ROW at Dameron St was starting to get narrow and overgrown, but still appeared to be accessible. Manholes Yes No NA NE Please list the Manholes Inspected: Cotton Creek Rd Are manholes accessible? ❑ ❑ ❑ # Are manhole covers/vents above grade? ❑ ❑ ❑ Are manholes free of visible signs of overflow? ❑ ❑ ❑ Page 5 of 7 Permit: WQCS00168 Owner - Facility: Town of Star Inspection Date: 04/04/2024 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Are manholes free of sinkholes and depressions? 0 ❑ ❑ ❑ Are manhole covers present? 0 ❑ ❑ ❑ # Are manholes properly seated? 0 ❑ ❑ ❑ # Are manholes in good condition? 0 ❑ ❑ ❑ # Are inverts in good condition? 0 ❑ ❑ ❑ Is flow unrestricted in manholes? 0 ❑ ❑ ❑ Are manholes free of excessive amounts of grease? 0 ❑ ❑ ❑ Are manholes free of excessive roots? 0 ❑ ❑ ❑ Are manholes free of excessive sand? 0 ❑ ❑ ❑ Are manhole vents screened? ❑ ❑ ❑ Are vents free of submergence? 0 ❑ ❑ ❑ Are manholes free of bypass structures or pipes? 0 ❑ ❑ ❑ Comment: The manhole at Cotton Creek road school was viewed and was in good condition at the time of the inspection. Pump Stations Yes No NA NE Please list the Pump Stations Inspected: #2, #6, #7, #8 # Number of duplex or larger pump stations in system 8 # Number of vacuum stations in system # Number of simplex pump stations in system # Number of simplex pump stations in system serving more than one building How many pump/vacuum stations have: # A two-way "auto polling" communication system (SCADA) installed? # A simple one-way telemetry/communication system (auto -dialer) installed? 0 For pump stations inspected: Are they secure with restricted access? ❑ ❑ ❑ Were they free of by-pass structures/pipes? ❑ ❑ ❑ Were wet wells free of excessive grease/debris? ❑ ❑ ❑ # Do they all have telemetry installed? ❑ ❑ ❑ Is the communication system functional? ❑ ❑ ❑ Is a 24-hour notification sign posted ? ❑ ❑ ❑ Does the sign include: Owner Name? ❑ ❑ ❑ Pump station identifier? ❑ ❑ ❑ # Address? ❑ ❑ ❑ Instructions for notification? ❑ ❑ ❑ 24-hour emergency contact numbers? 0 ❑ ❑ ❑ Page 6 of 7 Permit: WQCS00168 Owner - Facility: Town of Star Inspection Date: 04/04/2024 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Are audio and visual alarms present? 0 ❑ ❑ ❑ Are audio and visual alarms operable? 0 ❑ ❑ ❑ # Is there a backup generator or bypass pump connected? ❑ ❑ 0 ❑ If tested during inspection, did it function properly? ❑ ❑ 0 ❑ Is the back-up system tested at least bi-annually under normal operating conditions? ❑ ❑ 0 ❑ # Does it have a dedicated connection for a portable generator? ❑ ❑ ❑ # Is the owner relying on portable units in the event of a power outage? ❑ ❑ 0 ❑ # If Yes, is there a distribution plan? ❑ ❑ 0 ❑ If Yes, what resources (Units/Staff/Vehicles/etc) are included in Plan? # Does Permittee have the approved percentage of replacement simplex pumps? ❑ ❑ 0 ❑ Is recordkeeping of pump station inspection and maintenance program adequate? 0 ❑ ❑ ❑ Do pump station logs include at a minimum Inside and outside cleaning and debris removal? 0 ❑ ❑ ❑ Inspecting and exercising all valves? 0 ❑ ❑ ❑ Inspecting and lubricating pumps and other equipment? 0 ❑ ❑ ❑ Inspecting alarms, telemetry and auxiliary equipment? 0 ❑ ❑ ❑ Comment: Pump stations 2, 6, 7, and 8 were inspected. At the time of the inspection, all pump stations were secure with proper signage and all wet wells were clear of excess debris. Only one alarm was tested during the inspection and it was working at that time. Permittee does not know how to test the other alarms, which are transducers. All the pump stations have only one working pump even though the pump stations are duplex. Replacement pumps are avaiable for each pump station. Page 7 of 7 ■ Complete items 1, 2, and 3. ■ Print your name and address on the reverse so that we can return the card to you. ■ Attach this card to the back of the mallpiece, or on the front if space permits. 1. Article Addressed to: TOWN OF STAR ATTN: BILL HUDSON, MAYOR P.O. BOX 97 STAR, NC 27356 IIIIIIIII IIII IIIIIIIIIIII III III IIII IIIIII II III 9590 940 �1 O Agent D. Is delivery address different from item 17 ❑ Yes If YES, enter delivery address below: ❑ No 3. Service Type ❑ Priority Mail Express® 0 Adult Signature ❑ Registered Mail* ❑ Adult Signature Restricted Delivery ❑ Registered Mall Restricted tCertlfled Mail® Delivery 2 8653 3244 6731 77 Certified Mall Restricted Delivery (signature Connmiaaonn• ❑ collect on Delivery ❑ Signature Confirmation 2. Article Number (transfer from service labep 10 Collect on Delivery Restricted Delivery Restricted Delivery, 'd Mail 7022 2410 0002 5119 6116 1 oalil Restricted Delivery PS Form 3811, July 2020 PSN 753D-02•000-9053 Domestic Return Receipt ; USPS TRACMG # 270 Fi st-Class Mail 11111111 L 111111 Pe m t No. G-10 Paid 9590 9402 8653 3244 6731 77 United States u P. 'I.e Er' o Uj N Z rram�[ o w J J D � W �r Q 0 Sender: Please print your name, NCDEQ — DWR - WQROS ATTN: KIRSTEN STEININGER 225 GREEN STREET, SUITE 714 FAYETTEVILLE, NC 28301 li11ldi,hh111111q ,.ih,nlmthmrb1fill,I)M) i III'll