HomeMy WebLinkAboutSW6240103_Design Calculations_20240425 (3) HY-8 Culvert Analysis Report
Crossing Discharge Data
Discharge Selection Method: User Defined
Table 1-Summary of Culvert Flows at Crossing:STREAM CROSS PIPE
Headwate Discharge Total PIPE 1A PIPE 113 Roadway Iterations
r Names Discharg Discharg Discharg Discharg
Elevation e (cfs) e (cfs) e (cfs) e (cfs)
(ft)
206.30 10 70.13 37.66 32.47 0.00 5
206.56 25 78.17 40.51 37.67 0.00 5
208.40 Overtoppin 117.53 51.05 66.49 0.00 Overtoppin
g g
Rating Curve Plot for Crossing:STREAM CROSS PIPE
Total Rating Curve
Crossing:STREAM CROSS PIPE
206.55-
206 50-
c -
0
R,206.45-
w -
a -
io
206.40-
a)
I
206 35-
206.30-
I
70 71 72 73 74 75 76 77 78
Total Discharge(cfs)
Culvert Data: PIPE 1A
Table 1-Culvert Summary Table: PIPE 1A
Disc Total Culv Head Inle Out Fl Nor Crit Ou Tail Outl Tail
harg Disc ert water t let o mal ical tle wate et wate
e harg Disc Eleva Con Con w Dep De t r Vel r
Nam e harg tion trol trol Ty th pth De Dept ocit Velo
es (cfs) e (ft) Dep Dep pe (ft) (ft) pth h (ft) y city
(cfs) th th (ft) (ft/ (ft/s
(ft) (ft) s) )
10 70.13 37.66 206.3 2.75 3.17 3- 2.80 1.5 2.1 2.15 5.38 3.44
cfs cfs 0 9 M 9 5
2t
25 78.17 40.51 206.5 2.91 3.44 7- 2.80 1.6 2.2 2.26 5.57 3.54
cfs cfs 6 1 M 6 6
2t
Culvert Barrel Data
Culvert Barrel Type Straight Culvert
Inlet Elevation (invert): 203.12 ft,
Outlet Elevation (invert): 202.60 ft
Culvert Length: 102.00 ft,
Culvert Slope: 0.0051
Culvert Performance Curve Plot: PIPE 1A
Performance Curve
Culvert:PIPE 1A
0 0
Inlet Control Elev Outlet Control Elev
- r■
2IIl 5-
206A- - _ -
5206.3- k
w -
a
a -
w -
:5 2062-
w
3 -
1373
-
z 206.1
2(ir;Ci
205
I I I I I I I I I I I
70 71 7373 74 75 77 78
Total Discharge(cfs)
Water Surface Profile Plot for Culvert: PIPE 1A
Crossing- STREAM CROSS PIPE, Design Discharge - 78.2 cfs
Culvert-PIPE 1..Culvert Discharge-40.5 cfs
208-
207-
206-
m 205-
a
w
w
204
203-
202-
I I I I I
-20 0 20 40 60 80 100 120
Station(ft)
Site Data - PIPE 1A
Site Data Option: Culvert Invert Data
Inlet Station: 0.00 ft
Inlet Elevation: 202.42 ft
Outlet Station: 102.00 ft
Outlet Elevation: 201.90 ft
Number of Barrels: 1
Culvert Data Summary - PIPE 1A
Barrel Shape: Circular
Barrel Diameter: 3.50 ft
Barrel Material: Concrete
Embedment: 8.40 in
Barrel Manning's n: 0.0120 (top and sides)
Manning's n: 0.0350 (bottom)
Culvert Type: Straight
Inlet Configuration: Square Edge with Headwall (Ke=0.5)
Inlet Depression: None
Culvert Data: PIPE 1B
Table 2-Culvert Summary Table: PIPE 1B
Disc Total Culv Head Inle Out Fl Nor Crit Ou Tail Outl Tail
harg Disc ert water t let o mal ical tle wate et wate
e harg Disc Eleva Con Con w Dep De t r Vel r
Nam e harg tion trol trol Ty th pth De Dept ocit Velo
es (cfs) e (ft) Dep Dep pe (ft) (ft) pth h (ft) y city
(cfs) th th (ft) (ft/ (ft/s
(ft) (ft) s) )
10 70.13 32.47 206.3 2.68 1.92 1- 1.72 1.8 1.7 2.15 7.70 3.44
cfs cfs 0 7 S2 5 3
n
25 78.17 37.67 206.5 2.94 2.28 1- 1.90 2.0 1.9 2.26 7.97 3.54
cfs cfs 6 1 S2 0 0
n
Culvert Barrel Data
Culvert Barrel Type Straight Culvert
Inlet Elevation (invert): 203.62 ft,
Outlet Elevation (invert): 203.10 ft
Culvert Length: 102.00 ft,
Culvert Slope: 0.0051
Culvert Performance Curve Plot: PIPE 1B
Performance Curve
Culvert:PIPE 1B
I • I AlI
Inlet Control Elev Outlet Control Elev
206.6-
206.5
206.4--
206.3-
206.2-_
0 —
co
206.1-_
w -
m 206.0-_
ai 205.9-
I
205.8-
205.7-
205.E-
♦--
205.5 LrI I
70 71 7? 73 74 75 7t77 7:
Total Discharge(cfs)
Water Surface Profile Plot for Culvert: PIPE 1B
Crossing- STREAM CROSS PIPE,Design Discharge- 78.2 cfs
Culvert-PIPE 1B,Culvert Discharge-37-7 cfs
208.5
208-0-
207-5-
207-0-
206-5-
206-0-
c -
0 205-5-
m
w —
w 205-0-
204-5-
- ill .
204_0-
203-5-
203-0-
202-5-
2Ci 0 20 40 60 80 1 Do 120
Station(ft)
Site Data - PIPE 1B
Site Data Option: Culvert Invert Data
Inlet Station: 0.00 ft
Inlet Elevation: 203.62 ft
Outlet Station: 102.00 ft
Outlet Elevation: 203.10 ft
Number of Barrels: 1
Culvert Data Summary - PIPE 1B
Barrel Shape: Circular
Barrel Diameter: 3.00 ft
Barrel Material: Concrete
Embedment: 0.00 in
Barrel Manning's n: 0.0120
Culvert Type: Straight
Inlet Configuration: Grooved End in Headwall
Inlet Depression: None
Tailwater Data for Crossing: STREAM CROSS PIPE
Table 2- Downstream Channel Rating Curve (Crossing:STREAM CROSS PIPE)
Flow(cfs) Water Velocity Depth (ft) Shear(psf) Froude
Surface (ft/s) Number
Elev(ft)
70.13 204.75 2.15 3.44 0.67 0.54
78.17 204.86 2.26 3.54 0.71 0.54
Tailwater Channel Data - STREAM CROSS PIPE
Tailwater Channel Option: Trapezoidal Channel
Bottom Width: 3.00 ft
Side Slope (H:V): 3.00 (_:1)
Channel Slope: 0.0050
Channel Manning's n: 0.0350
Channel Invert Elevation: 202.60 ft
Roadway Data for Crossing: STREAM CROSS PIPE
Roadway Profile Shape: Constant Roadway Elevation
Crest Length: 50.00 ft
Crest Elevation: 208.40 ft
Roadway Surface: Paved
Roadway Top Width: 32.00 ft