Loading...
HomeMy WebLinkAboutWQ0021934_ Aqua-Hasentree WWTF Inspection letter_20240328 DocuSign Envelope ID:7424B504-BB51-44D3-B71A-7893DC8A6438 .lac STATE of � e'✓y o,113 ROY COOPER Governor v ELIZABETH S.BISER Secretary *+ RICHARD E.ROGERS,JR. NORTH CAROLINA Director Environmental Quality March 28, 2024 Shannon V Becker - President Aqua North Carolina, Inc 202 MacKenan Court Cary, NC 27511 Subject: Compliance Evaluation Inspection Aqua - Hasentree WWTF and Reclaimed Water Generation and Non-conjunctive reclaimed water utilization Nondischarge Permit WQ0021934 Wake Forest, NC Wake County Dear Permittee: On February 7, 2024, Dorothy Robson and Donald Smith from the Raleigh Regional Office visited your facility to evaluate compliance with the Nondischarge Permit WQ0021934. Division records indicate the facility operates a reclaim water generation, non-conjunctive utilization, and distribution of reclaimed water utilization facility. Roger Tupps and Patrick Casey with Aqua and Seth Holland with Hasentree assisted during the inspection. They were very helpful and answered many questions. During the inspection, the following was observed: Schedule (Section I of permit): 1. Appropriate education was observed and appeared to be sufficient to inform users and employees of the reclaimed water irrigation. Performance (Section II): 2. The facility maintains and operates the reclaimed water facilities as described in the permit. 3. All reclaimed water components are labeled or colored purple as described in the permit as well as signage located throughout the reclaimed water distribution area. 4. Irrigation application rates are applied to the fields as permitted based on review of the NDARs. 5. No drinking water wells are located on or within the compliance boundaries. Operation and Maintenance (O&M) (Section III): 1. The permittee operates and maintains the reclaim water system and the distribution system as a non-discharge system. An Operation and Maintenance (0&M) Plan, Spill control prevention plan (SPCP), and safety measures are readily available and observed. 2. Vegetative cover on the irrigation areas was maintained and no ponding or runoff was observed. 3. Public access is restricted at the wastewater treatment and storage ponds. 4. Continuous monitoring and recording are utilized for turbidity. 5. Flow meters are maintained and calibrated yearly. 6. Standby power is maintained as described in the permit. 7. Freeboard in both the storage pond and upset ponds were below two feet based on review of the N DARs. 8. The facility has established an education program to inform golfers and other guests of the DocuSign Envelope ID:7424B504-BB51-44D3-B71A-7893DC8A6438 Page 12 reclaimed water irrigation system. Monitoring and Reporting (Section IV): 9. Reclaimed water is sampled and monitored for compliance in accordance with the permit. 10. Record tracking documents were well maintained and readily available for review. 11. Irrigation rates and flow is documented daily. 12. Reclaimed water effluent is monitored and sampled in accordance with Attachment A of the permit. 13. Reclaimed water utilization is tracked in accordance with Attachment B of the permit. 14. Maintenance logs were observed to be complete. 15. Monitoring wells are sampled at the frequency as specified in the permit. Inspections (Section V): 16. The facility performs maintenance and inspects the facility daily and maintains written and digital logs. General Conditions 17. The permittee is in compliance with the permit conditions. This report is a notification of the results of the compliance inspection. No violations were observed at the time of the inspection. If you have questions or comments about this inspection, then please contact via email at dorothy.robson@deq.nc.gov or 919-791-4200. Sincerely, E ADoccuSigned by: U&Ad W 372DCBCB61EE4A8... Michael Hall, Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ Attachment(s): NCDEQ Compliance Inspection Form Ec: Laserfiche DocuSign Envelope ID:7424B504-BB51-44D3-B71A-7893DC8A6438 Compliance Inspection Report Permit:WQ0021934 Effective: 04/12/23 Expiration: 07/31/29 Owner: Aqua North Carolina Inc SOC: Effective: Expiration: Facility: Hasentree WWTP County: Wake Hasentree Way Region: Raleigh Wake Forest NC 27587 Contact Person:Thomas J Roberts Title: Phone: 919-467-8712 Ext.30 Directions to Facility: Hasentree WWTP os located on Hasentree Club Drive in Wake Forest, NC of off NC Highway 98 System Classifications: SI, WW2, Primary ORC: Roger Tupps, Certification: Phone: Secondary ORC(s): Patrick Casey On-Site Representative(s): Seth Holland Related Permits: WQ0033816 Hasentree Owners Association Inc-Hasentree Golf Community CUS Inspection Date: 02/07/2024 Entry Time 10:OOAM Exit Time: 12:OOPM Primary Inspector:Dorothy M Robson Phone: 919-791-4200 Secondary Inspector(s): Donald Smith Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Reclaimed Water Facility Status: Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions Treatment Treatment Barscreen Treatment Filters Record Keeping Treatment Lagoons End Use-Irrigation Treatment Clarifiers Treatment Disinfection Standby Power (See attachment summary) Page 1 of 6 DocuSign Envelope ID:7424B504-BB51-44D3-B71A-7893DC8A6438 Permit: WQ0021934 Owner-Facility:Aqua North Carolina Inc Inspection Date: 02/07/2024 Inspection Type:Compliance Evaluation Reason for Visit: Routine Inspection Summary: On February 7, 2024, Dorothy Robson and Donald Smith from the Raleigh Regional Office visited your facility to evaluate compliance with the Nondischarge Permit WQ0021934. Division records indicate the facility operates a reclaim water generation, non-conjunctive utilization, and distribution of reclaimed water utilization facility.Roger Tupps and Patrick Casey with Aqua and Seth Holland with Hasentree assisted during the inspection. They were very helpful and answered many questions. During the inspection, the following was observed: Schedule (Section I of permit): 1. Appropriate education was observed and appeared to be sufficient to inform users and employees of the reclaimed watel irrigation. Performance (Section II): 2. The facility maintains and operates the reclaimed water facilities as described in the permit. 3. All reclaimed water components are labeled or colored purple as described in the permit as well as signage located throughout the reclaimed water distribution area. 4. Irrigation application rates are applied to the fields as permitted based on review of the NDARs. 5. No drinking water wells are located on or within the compliance boundaries. Operation and Maintenance (O&M) (Section III): 1. The permittee operates and maintains the reclaim water system and the distribution system as a non-discharge system. An Operation and Maintenance (O&M) Plan, Spill control prevention plan (SPCP), and safety measures are readily available and observed. 2. Vegetative cover on the irrigation areas was maintained and no ponding or runoff was observed. 3. Public access is restricted at the wastewater treatment and storage ponds. 4. Continuous monitoring and recording are utilized for turbidity. 5. Flow meters are maintained and calibrated yearly. 6. Standby power is maintained as described in the permit. 7. Freeboard in both the storage pond and upset ponds were below two feet based on review of the NDARs. 8. The facility has established an education program to inform golfers and other guests of the reclaimed water irrigation system. Monitoring and Reporting (Section IV): 9. Reclaimed water is sampled and monitored for compliance in accordance with the permit. 10. Record tracking documents were well maintained and readily available for review. 11. Irrigation rates and flow is documented daily. 12. Reclaimed water effluent is monitored and sampled in accordance with Attachment A of the permit 13. Reclaimed water utilization is tracked in accordance with Attachment B of the permit. 14. Maintenance logs were observed to be complete. 15. Monitoring wells are sampled at the frequency as specified in the permit. Inspections (Section V): 16. The facility performs maintenance and inspects the facility daily and maintains written and digital logs. General Conditions 17. The permittee is in compliance with the permit conditions. This report is a notification of the results of the compliance inspection. No violations were observed at the time of the inspection Page 2 of 6 DocuSign Envelope ID:7424B504-BB51-44D3-B71A-7893DC8A6438 Permit: WQ0021934 Owner-Facility:Aqua North Carolina Inc Inspection Date: 02/07/2024 Inspection Type:Compliance Evaluation Reason for Visit: Routine Type Yes No NA NE Reuse(Quality) ❑ Infiltration System ❑ Lagoon Spray, LR ❑ Single Family Spray, LR ❑ Activated Sludge Spray, LR ❑ Activated Sludge Spray, HR ❑ Single Family Drip ❑ Activated Sludge Drip, LR ❑ Recycle/Reuse ❑ Treatment Yes No NA NE Are Treatment facilities consistent with those outlined in the current permit? 0 ❑ ❑ ❑ Do all treatment units appear to be operational? (if no, note below.) 0 ❑ ❑ ❑ Comment: None Standby Power Yes No NA NE Is automatically activated standby power available? 0 ❑ ❑ ❑ Is generator tested weekly by interrupting primary power source? ❑ ❑ ❑ Is generator operable? ❑ ❑ ❑ Does generator have adequate fuel? 0 ❑ ❑ ❑ Comment: None Treatment Barscreen Yes No NA NE Is it free of excessive debris? 0 ❑ ❑ ❑ Is disposal of screenings in compliance? 0 ❑ ❑ ❑ Are the bars spaced properly? 0 ❑ ❑ ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment: None Treatment Clarifiers Yes No NA NE Are the weirs level? ❑ ❑ ❑ Are the weirs free of solids and algae? ❑ ❑ ❑ Is the scum removal system operational? ❑ ❑ ❑ Is the scum removal system accessible? ❑ ❑ ❑ Is the sludge blanket at an acceptable level? 0 ❑ ❑ ❑ Is the effluent from the clarifier free of excessive solids? 0 ❑ ❑ ❑ Comment: None Page 3 of 6 DocuSign Envelope ID:7424B504-BB51-44D3-B71A-7893DC8A6438 Permit: WQ0021934 Owner-Facility:Aqua North Carolina Inc Inspection Date: 02/07/2024 Inspection Type:Compliance Evaluation Reason for Visit: Routine Treatment Filters Yes No NA NE Is the filter media present? E ❑ ❑ ❑ Is the filter media the correct size and type? ❑ ❑ ❑ Is the air scour operational? ❑ ❑ ❑ Is the scouring acceptable? 0 ❑ ❑ ❑ Is the clear well free of excessive solids? ❑ ❑ ❑ Is the mud well free of excessive solids and filter media? ❑ ❑ ❑ Does backwashing frequency appear adequate? 0 ❑ ❑ ❑ Comment: None Treatment Disinfection Yes No NA NE Is the system working? 0 ❑ ❑ ❑ Do the fecal coliform results indicate proper disinfection? ❑ ❑ ❑ Is there adequate detention time(>=30 minutes)? ❑ ❑ ❑ Is the system properly maintained? ❑ ❑ ❑ If gas, does the cylinder storage appear safe? ❑ ❑ ❑ Is the fan in the chlorine feed room and storage area operable? ❑ ❑ ❑ Is the chlorinator accessible? ❑ ❑ ❑ If tablets, are tablets present? ❑ ❑ ❑ Are the tablets the proper size and type? ❑ ❑ ❑ Is contact chamber free of sludge, solids, and growth? ❑ ❑ ❑ If UV, are extra UV bulbs available? ❑ ❑ ❑ If UV, is the UV intensity adequate? ❑ ❑ ❑ # Is it a dual feed system? ❑ ❑ ❑ Does the Stationary Source have more than 2500 Ibs of Chlorine(CAS No. 7782-50-5)? ❑ ❑ ❑ If yes,then is there a Risk Management Plan on site? ❑ ❑ ❑ If yes,then what is the EPA twelve digit ID Number? (1 000- - ) If yes,then when was the RMP last updated? Comment: None Record Keeping Yes No NA NE Is a copy of current permit available? ❑ ❑ ❑ Are monitoring reports present: NDMR? ❑ ❑ ❑ NDAR? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Are application rates adhered to? ❑ ❑ ❑ Is GW monitoring being conducted, if required (GW-59s submitted)? 0 ❑ ❑ ❑ Page 4 of 6 DocuSign Envelope ID:7424B504-BB51-44D3-B71A-7893DC8A6438 Permit: WQ0021934 Owner-Facility:Aqua North Carolina Inc Inspection Date: 02/07/2024 Inspection Type:Compliance Evaluation Reason for Visit: Routine Are all samples analyzed for all required parameters? 0 ❑ ❑ ❑ Are there any 2L GW quality violations? ❑ 0 ❑ ❑ Is GW-59A certification form completed for facility? 0 ❑ ❑ ❑ Is effluent sampled for same parameters as GW? 0 ❑ ❑ ❑ Do effluent concentrations exceed GW standards? ❑ 0 ❑ ❑ Are annual soil reports available? 0 ❑ ❑ ❑ #Are PAN records required? ❑ 0 ❑ ❑ #Did last soil report indicate a need for lime? ❑ ❑ 0 ❑ If so, has it been applied? ❑ ❑ 0 ❑ Are operational logs present? 0 ❑ ❑ ❑ Are lab sheets available for review? 0 ❑ ❑ ❑ Do lab sheets support data reported on NDMR? 0 ❑ ❑ ❑ Do lab sheets support data reported on GW-59s? 0 ❑ ❑ ❑ Are Operational and Maintenance records present? 0 ❑ ❑ ❑ Were Operational and Maintenance records complete? 0 ❑ ❑ ❑ Has permittee been free of public complaints in last 12 months? 0 ❑ ❑ ❑ Is a copy of the SOC readily available? ❑ ❑ 0 ❑ No treatment units bypassed since last inspection? ❑ ❑ ❑ Comment: None End Use-Irrigation Yes No NA NE Are buffers adequate? ❑ ❑ ❑ Is the cover crop type specified in permit? ❑ ❑ ❑ Is the crop cover acceptable? ❑ ❑ ❑ Is the site condition adequate? 0 ❑ ❑ ❑ Is the site free of runoff/ponding? ❑ ❑ ❑ Is the acreage specified in the permit being utilized? ❑ ❑ ❑ Is the application equipment present? ❑ ❑ ❑ Is the application equipment operational? ❑ ❑ ❑ Is the disposal field free of limiting slopes? ❑ ❑ ❑ Is access restricted and/or signs posted during active site use? ❑ ❑ ❑ Are any supply wells within the CB? ❑ ❑ ❑ Are any supply wells within 250' of the CB? ❑ ❑ ❑ How close is the closest water supply well? ❑ ❑ ❑ Is municipal water available in the area? ❑ ❑ ❑ # Info only: Does the permit call for monitoring wells? ❑ ❑ ❑ Are GW monitoring wells located properly w/respect to RB and CB? 0 ❑ ❑ ❑ Page 5 of 6 DocuSign Envelope ID:7424B504-BB51-44D3-B71A-7893DC8A6438 Permit: WQ0021934 Owner-Facility:Aqua North Carolina Inc Inspection Date: 02/07/2024 Inspection Type:Compliance Evaluation Reason for Visit: Routine Are GW monitoring wells properly constructed, including screened interval? 0 ❑ ❑ ❑ Are monitoring wells damaged? ❑ 0 ❑ ❑ Comment: None Yes No NA NE Page 6 of 6