Loading...
HomeMy WebLinkAboutSW6130203_Supplement-EZ Form_20240423 SUPPLEMENT-EZ COVER PAGE PROJECT INFORMATION 1 Pro'ect Name O'Reilly Auto Parts Area Infiltration Basin 2 Pro'ect Area(ac) 8.977548 3 Coastal Wetland Area(ac) 4 Surface Water Area(ac) 5 Is this project High or Low Density? High 6 Does this project use an off-site SCM? No COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided(feet) _ _ 30 8 Will the vegetated setback remain vegetated? Yes j 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A r 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: I 11 Infiltration System 1 _ 12 -Bioretention Cell 13 Wet Pond 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 17 Rainwater Harvesting(RWH) 18 Green Roof — -- --_19 Level Spreader-Filter Strip(LS-FS) 20 Disconnected Impervious Surface(DIS) 21 Treatment Swale 22 Dry Pond 23 StormFilter 24 Silva Cell 25 Bayfilter _ 26 Filterra FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Jarrod E.Hilliard,PE,CFM 28 Or!anization: Hilliard Engineering, PLLC •Street address: 3417 Winterwind Circle 30 Cit ,State,Zip: Sanford, NC 27330 31 Phone number(s): 919-352-2834 32 Email: jhilliard@hilliardengineering.com Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer ,,`I11111t1P5t. ,,,, 110, • •� ,SSO•• 2 �i !Q- 1,1% S • Si ature of Designer 99"" // i e Q SEAL ��: — �/d�C l alrt�, (2/Z6 035670 7 r� / P" A11111/ 4-j 3/ Seal Date DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so,number of drainage areas/SCMs 1 3 Does this project have low density areas? No 4 If so,number of low density drainage areas 0 Is all/part of this project subject to previous rule 5 [versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 ,. 1 4 Type of SCM Infiltration Basin Infiltration Basin 4F 5 Total drainage area(sq ft) 391,062 374616 6 Onsite drainage area(sq ft) 391,062 374616 7 Offsite drainage area(sq ft) 8 Total BUA in project(sq ft) 318424 sf 318424 sf New BUA on subdivided lots(subject to permitting) 9 , s' ft) 297634 sf 297634 sf New BUA not on subdivided lots(subject to 10 permittn.)(sf) 20800 sf 20800 sf _ En Offsite BUA(sq ft) lal Breakdown of new BUA not on subdivided lots: _ -Parking(sq ft) agi -Sidewalk(sq ft) 1111111 -Roof(sq ft) _ -Roadway(sq ft) 20800 sf 20800 sf _ -Future(sq ft) -Other,please specify in the comment box below(sq ft) New infiltrating permeable pavement on 13 subdivided lots(sq ft) New infiltrating permeable pavement not on 14 subdivided lots(sq ft) Existing BUA that will remain(not subject to 1 15 `permitting)(sq ft) 16 Existing BUA that is already permitted(sq ft) 17 Existing BUA that will be removed(sq ft) 18 Percent BUA 81% 85% 19 Design storm(inches) 1.0 in 20 Design volume of SCM(cu ft) 25444 cf 21 Calculation method for design volume simple ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 ;drainage area(s):