Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0034367_Monitoring - 01-2024_20240227
Monitoring Report Submittal Permit Number#* W00034367 Name of Facility:* Onslow Water and Sewer Authority - Northwest Regional Water Reclamation Facility Month: * January Year: * 2024 Report Information Type* Upload Document* NDMR, NDAR-1, NDAR-2, NDMLR NDAR & NDMR NWRWRF Jan 2024.pdf 4.45MB PDF Only Please upload one PDF containing all applicable monitoring reports (i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59). Confirmation Email Address: * sjones@onwasa.com Name of Submitter: * Sherry Jones Signature: Date of submittal: 2/27/2024 This will be filled in automatically Initial Review Reviewer: Wanda.Gerald Is the project number correct?* W00034367 Is the monitoring report accepted?* Yes NO Regional Office* Wilmington Reviewer: _anonymous Review Date: 4/23/2024 / FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page �__ of Permit No.: WQ0034367 Facility Name: Northwest Regional Water Reclamation Facility County: Onslow Month: January Year: 2024 PPI: 001 Flow Measuring Point: ❑ tnfluent O Effluent ❑ No flow generated Parameter Monitoring Point: ❑ influent 2 Effluent ❑ Groundwater Lowering ❑ Surface Water Parameter Code - 0- 50050 00310 00940 50060 31616 00610 00625 00620 00600 00400 00665 70300 00530 00076 p E UQ o c O U W o LL LO p 0 0 ara t ' z F- a. Z C 0 0 z o O o~IX n oY N i .9 c:° o ai a n ', ,v F- 24-hr hrs GPD mg/L mg/L mg/L #/100 mL mg/L mg/L mg/L mg/L su mg/L mg/L mg/L NTU 1 346,600 0.36 7.16 2.67 2 13:15 1 510,600 3.09 0.27 <1.0 0.963 1.63 0.771 0.88 6.73 0.656 <2.50 2.17 3 09:00 5.25 599,500 2.27 0.29 <1.0 0.564 1.18 1.1 1.2 7.39 0.379 <2.50 1.92 4 08:00 8 467,100 3.28 0.31 <1.0 0.524 1.56 0.855 0.929 6.82 0.76 <2.50 1.5 5 1 14:15 1 477,500 0.25 6.94 1.23 6 583,600 0.18 7.02 1.49 7 352,200 0.2 7.01 0.74 8 07:00 8 587,500 <2.00 0.22 <1.00 <0.500 1.2 3.14 3.23 6.81 0.898 <2.50 1.24 9 09:00 4 448,900 2.6 0.2 <1.00 <0.500 1.19 3.31 3.39 7.32 0.886 <2.50 0.99 10 09:00 8 628,400 <2.00 0.14 <1.00 <0.500 1.22 4.46 4.51 7.13 1.44 <2.50 0.99 11 09:00 8 626,800 0.25 7.35 1.24 12 10:35 1 607,600 0.26 6.89 1.74 13 07:00 8 659,100 0.27 7.07 1.49 14 07:00 8 476,800 0.32 7.16 1.24 15 09:00 3 566,900 0.29 6.94 0.99 16 09:00 1 477,400 <2.00 0.25 <1.00 0.797 <1.00 11.6 11.6 7.36 2.29 <2.50 0.66 17 07:00 8 574,600 <2.00 0.28 <1.00 <0.500 1.82 11.4 11.4 7.25 2.48 <2.50 0.41 18 12:00 4 422,400 <2.00 0.17 <1.00 <0.500 1.22 12.9 13 7.09 2.7 <2.50 0.49 19 17:00 1 601,200 0.27 6.9 0.74 20 407,200 0.18 7.06 0.49 21 460,200 0.21 6.99 0.74 22 08:00 8 273,400 3.46 0.35 <1.00 <0.500 2.79 14.4 14.4 7.02 2.8 <2.50 1.46 23 08:00 8 579,900 5.72 0.48 <1.00 0.811 1.56 14.7 14.8 7.2 2.84 <2.50 4.86 24 08:00 8 306,100 <2.00 0.11 <1.00 <0.500 4.42 11.6 11.8 6.8 3.15 <2.50 6.61 25 08:00 8 456,300 0.12 6.97 8.87 26 08:00 8 444,700 0.09 7.43 7.6 27 427,600 0.18 7.16 4.77 28 395,800 0.24 7.18 2.75 29 05:45 8 415,600 <2.00 0.15 <1.00 1.92 3.92 2 2.58 7 2.32 <2.50 1.24 30 17:00 1 334,600 2.13 0.15 <1.00 1.49 2.65 3 3.44 7.38 1.84 <2.50 0.74 311 11:30 1 1.5 374,600 <2.00 0.13 <1.00 0.671 1.57 3.64 3.82 7.33 1.02 <2.50 0.74 Average: 480,345 1.50 0.23 1.00 0.52 1.86 6.59 6.73 1.71 0.00 2.09 Daily Maximum: 659,100 5.72 0.48 1.00 1.92 4.42 14.70 14.80 7.43 3.15 2.50 8.87 Daily Minimum: 273,400 2.00 0.09 1.00 0.50 1.00 0.77 0.88 6.73 0.38 2.50 0.41 Sampling Type: Recorder Composite Composite Grab Grab Composite Composite Composite Composite Grab Composite Composite Composite Recorder Monthly Avg. Limit: 1,272,9731 10 14 4 1 10 7 3 5 Daily Limit: 15 25 6 6.0 - 9.0 10 10 Sample Frequency: Continuous 3 x Week 3 x Year 5 x Week 3 x Week 3 x Week 3 x Week 3 x Week 3 x Week 5 x Week 3 x Week 3 x Year 3 x Week Continuous FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page � of %� Permit No.: W00034367 Facility Name: Northwest Regional Water Reclamation Facility County: Onslow Month: January Year: 2024 PPI: 002 Flow Measuring Point: ❑ Influent ❑ Effluent ❑ No flow generated Parameter Monitoring Point: ❑ Influent ❑ Effluent 0 Groundwater Lowering ❑ Surface Water Parameter Code —► 50050 00310 00680 00940 31616 00300 00610 00625 00620 00600 00400 00665 70300 ❑�m, CD E UQ ~ c 1U0 in W O 0 LL � O V rn o ° U 0 VU€ O° c E E L v 0 o Z CM ° 0 =O Z CL oO t a nE — °(0ic F- ° n O 24-hr hrs GPD mg/L mg/L mg/L #/100 mL mg/L mg/L mg/L mg/L mg/L su mg/L mg/L 1 0 2 13:15 1 0 3 09:00 5.25 0 4 08:00 8 0 5 14:15 1 0 6 0 7 0 8 07:00 8 0 9 09:00 4 0 10 09:00 8 0 11 09:00 8 0 12 10:35 1 0 13 07:00 8 0 14 07:00 8 0 15 09:00 3 0 161 09:00 1 0 17 07:00 8 0 18 12:00 4 0 19 17:00 1 0 20 0 21 0 22 08:00 1 8 0 23 08:00 8 0 24 08:00 8 0 25 08:00 8 0 26 08:00 8 0 27 0 28 0 29 05:45 8 0 30 17:00 1 0 31 11:30 1.5 0 Average: 0 Daily Maximum: 0 Daily Minimum: 0 Sampling Type: Recorder Grab Grab Grab Grab Grab Grab Grab Grab Grab Grab Grab Grab Monthly Avg. Limit: 500 Daily Limit: 482,632 Sample Frequency: Continuous 3 x Month 3 x Year 3 x Year 3 x Year 3 x Year 3 x Year 3 x Year 3 x Year 3 x Year 3 x Year 3 x �3. ,/ FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page 00, Permit No.: •11 . • -st Regional Water Reclamation. Onslow Month: January1 11 .III . •. ■ ■ ■ . •. ■ ■ ■ e7 • • • Me one 1 1 MOM 11---------------- ® 1 1 1 ©---------------- ----------- ® 1 : 1 1 ---------------- FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page of Permit No.: WQ0034367 Facility Name: Northwest-• • -r Reclamation• Month:1 11rim •. ■ ■ ■ . •. ■ ■ ■ o • • • © 1 • 1 1 ® 11®��----------- m lz© M 1 . 1 / ®�---------------- 1 1 /---------------- ® 1 : 1 1 ---------------- FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page -4—of Sampling Person(s) 11 Certified Laboratories Name: Mark Young, Perry Parker Name: ONWASA Laboratory Cert. # 539 Name: Ryan Pierce,Sean Pistorini,Eriane Collins, Randal Riggs Name: Envirochem Cert. # 94 Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? O Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Mark Young Permittee: Onslow Water and Sewer Authority Certification No.: 1001105 Signing Official: Seth Brown Grade: 4 Phone Number: 910-937-7570 Signing Official's Title: Treatment Facilities Administrator Has the ORC changed since the previous NDMR? ❑ Yes 121 No Phone Number: 910 937-7520 Permit Expiration: 2/28/2029 4; /,V re ate Stiat Signature Date By this sign ture cethis report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 FORM: NDAR-2 10-13 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page I of v Permit No.: W00034367 Facility Name: Northwest Regional WRF County: Onslow Month: January Year: 2024 Did infiltration occur at Site Name: Basin A Site Name: Basin B Site Name: Basin C Site Name: Basin D this facility? Area (acres): 2.37 Area (acres): 1.73 Area (acres): 1.73 Area (acres): 1.17 F±1 YES ❑ NO Rate (GPD/ft2): 8.736 Rate (GPD/ft): 3.286 Rate (GPD/ft): 0.72 Rate (GPD/ft): 1.408 Weather Freeboard Site Infiltrated? O YES ❑ NO Site Infiltrated? 2 YES ❑ NO Site Infiltrated? ❑ YES 0 NO Site Infiltrated? ❑ YES El NO m ❑ ° v '° m CL E F Q ` (L m@ o a N N - ? a Q. ❑ fa0 = E m Q 0 CL� Q m E__ ~ C -' c ,� 8 M ❑ J o O a y y c LL@ m E m � a 0 CLi Q °' �' E m _ ~ '� C > c a m ❑ J m p °' °°-' .0 N M• c a tL Q m 13 d �' E+a ~ C �, c ca :o ❑ J `° p o y a d m LLm E. Q 0 CL Q my _E ~ C >,c M 'U ❑ 0 o0 c N d N LLm °F in ft ft gal min GPD/ft2 ft gal min GPD/ft2 ft gal min GPD/ft2 ft gal min GPD/ft2 ft 1 37 0 8.5 307,0 00 1440 2.97 16.00 39,600 1440 0.53 16.00 0 0 0.00 14.00 0 0 0.00 11.70 2 33 0 8.5 428,100 1440 4.15 16.00 82,500 1440 1.09 16.00 0 0 0.00 14.00 0 0 0.00 11.70 328 IR 0.18 8.5 510,500 1440 4.94 16.00 89,000 1440 1.18 16.00 0 0 0.00 14.00 0 0 0.00 11.80 438 0 8.5 388,000 1440 3.76 16.00 79,100 1440 1.05 16.00 0 0 0.00 14.00 0 0 0.00 11.80 526 0 5.5 417,400 1440 4.04 16.00 60,100 1440 0.80 16.00 0 0 0.00 14.00 0 0 0.00 10.50 644 0.19 8.5 488,700 1440 4.73 16.00 94,900 1440 1.26 16.00 0 0 0.00 14.00 0 0 0.00 10.50 7 R 47 0.02 8.5 309,500 1440 3.00 16.00 42,700 1440 0.57 16.00 0 0 0.00 14.00 0 0 0.00 10.50 8 R 31 0,04 8.5 489,600 1440 4.74 16.00 97,900 1440 1.30 16.00 0 0 0.00 14.00 0 0 0.00 10.50 9 R 55 1.37 8.5 379,700 1440 3.68 16.00 69,200 1440 0.92 16.00 0 0 0.00 14.00 0 0 0.00 10.50 10 CL 47 0 8.5 523,700 1440 5.07 16.00 104,700 1440 1.39 1 16.00 0 0 0.00 14.00 0 0 0.00 10.50 11 R 34 0.02 8.5 534,800 1440 5.18 16.00 92,000 1440 1.22 16.00 0 0 0.00 14.00 0 0 0.00 10.30 12 R 32 0.3 8.5 4,894 1440 0.05 16.00 118,200 1440 1.57 16.00 0 0 0.00 14.00 0 0 0.00 10.30 13 C 58 0 8.5 560,300 1440 5.43 16.00 98,800 1440 1.31 16.00 0 0 0.00 14.00 0 0 0.00 10.40 14 C 33 0 8.6 384,700 1440 3.73 16.00 92,100 1440 1.22 16.00 0 0 0.00 14.00 0 0 0.00 10.40 15 C 38 0 8.6 483,400 1440 4.68 16.00 83,500 1440 1.11 1 16.00 0 0 1 0.00 14.00 0 0 0.00 10.40 16 C 48 0 8.6 385,300 1440 3.73 16.00 92,100 1440 1.22 16.00 0 0 0.00 14.00 0 0 0.00 10.40 17 C 27 0 8.6 476,100 1440 4.61 16.00 98,500 1440 1.31 16.00 0 0 0.00 14.00 0 0 0.00 10.40 18 C 19 0 8.6 342,200 1440 3.31 16.00 80,200 1440 1.06 16.00 0 0 0.00 14.00 0 0 0.00 10.40 19 CL 45 0 8.6 490,000 1440 4.75 16.00 111,200 1440 1.48 16.00 0 0 0.00 14.00 0 0 0.00 10.40 20 C 26 0 7.5 336,100 1440 3.26 16.00 71,100 1440 0.94 16.00 0 0 0.00 14.00 0 0 0.00 10.70 21 C 19 0 7.5 385,800 1440 3.74 16.00 74,400 1440 0.99 16.00 0 0 0.00 14.00 0 0 0.00 10.70 22 C 16 0 7.5 222,200 1440 2.15 16.00 51,200 1440 0.68 1 16.00 0 0 0.00 14.00 0 0 0.00 10.70 23 CL 32 0 7.5 488,700 1440 4.73 16.00 91,200 1440 1.21 16.00 0 0 0.00 14.00 0 0 0.00 10.70 24 CL 54 0 7.5 252,200 1440 2.44 16.00 53,900 1440 0.72 16.00 0 0 0.00 14.00 0 0 0.00 10.70 25 R 60 0.09 7.5 373,800 1440 3.62 16.00 82,500 1440 1.09 16.00 0 0 0.00 14.00 0 0 0.00 10.70 26 R 64 0.12 7.5 366,800 1440 3.55 16.00 77,900 1440 1.03 16.00 0 0 0.00 14.00 0 0 0.00 10.70 27 R 58 0.15 8.3 350,400 1440 3.39 16.00 77,200 1440 1.02 16.00 0 0 0.00 14.00 0 0 0.00 11.00 28 R 67 0.15 1 8.3 336,700 1440 3.26 16.00 59,100 1440 0.78 16.00 0 0 0.00 14.00 0 0 0.00 11.00 0 7.5 336,400 1440 3.26 16.00 79,200 1440 1.05 16.00 0 0 0.00 14.00 0 0 0.00 11.00 LICL L41 0 7.8 272,400 1440 2.64 16.00 62,200 1440 0.83 16.00 0 0 0.00 14.00 0 0 0.00 11.20 0 7.5 301,700 1440 2.92 16.00 72,900 E ' x 1440 d ° 0.97 1 06 16.00 0 ,, �� �y, 0 :. 0.00 0.00N 14.00 0 fz 0 0.00 0.00 11.20 ? MonthlyLoading GPDIft 9 ( ) 3.73 3.731,, Year to Date Loading (GPD/ft2). 1.06 0.00 a'� ;�� r " x *xa<< 0 00 s.�3, FORM: NDAR-2 10-13 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page Z_ of v Did the application rates exceed the limits in Attachment B of your permit? If not a basin, were the sites kept free of vegetation and raked? If not a basin, were there any instances of effluent ponding in or runoff from the sites? If a basin, were there any instances of breakout from the berms? Was the onsite automatically activated standby power source tested and operational? 0 Compliant ❑ Non -Compliant O Compliant ❑ Non -Compliant 0 Compliant ❑ Non -Compliant O Compliant ❑ Non -Compliant 0 Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Mark C. Young Permittee: Onslow Water & Sewer Authority Certification No.: 1001105 Signing Official: Seth Brown Grade: 4 Phone Number: 910-455-0722 Signing Officials Title: Treatment Facilities Administrator Has the ORC changed since the previous NDAR-27 ❑ Yes 0 No Phone Number: 910-937-7520 Permit Exp.: 2/28/29 W� Cr Sig at re D e Signature Date By this signature, I certify t 1 this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617