Loading...
HomeMy WebLinkAbout640001_Compliance Evaluation Inspection_20240401P-WP OrDivision of Water Resources Facility Number ®- ® O Division of Soil and Water Conservation O Other Agency Type of Visit: Compliance Inspection 0 Operation Review Q Structure Evaluation O Technical Assistance Reason for Visit: 0 Routine O Complaint O Follow-up O Referral O Emergency O Other O Denied Access Date of Visit: Arrival Time: ¢ Departure Time: ; County: �L Region: Farm Name: Owner Email: Owner Name: Phone: Mailing Address: Physical Address: Facility Contact: .. Title: L- Phone: (Z-fz:)9414Z Onsite Representative: Integrator: Certified Operator: Certification Number: Back-up Operator: Certification Number: Location of Farm: Swine Wean to Finish Wean to Feeder Feeder to Finish Farrow to Wean Farrow to Feeder Farrow to Finish Gilts Boars Other Latitude: Design Current Design Current Capacity Pop. Wet Poultry Capacity Pop. Layer Non -La er I I Ed rou Other Poults Design Current Discharges and Stream Impacts I . Is any discharge observed from any part of the operation? Discharge originated at: ❑ Structure ❑ Application Field ❑ Other: a. Was the conveyance man-made? b. Did the discharge reach waters of the State? (If yes, notify DWR) c. What is the estimated volume that reached waters of the State (gallons)? Longitude: Design Current Cattle Capacity Pop. Dairy Cow Dairy Calf Dairy Heifer Dry Cow .Non-Dairy Beef Stocker Beef Feeder Beef Brood Cow ❑ Yes gNo ❑ NA ❑ NE [:]Yes 0 No ❑ NA ❑ NE [:]Yes ❑ No ❑ NA ❑ NE d. Does the discharge bypass the waste management system? (If yes, notify DWR) 2. Is there evidence of a past discharge from any part of the operation? 3. Were there any observable adverse impacts or potential adverse impacts to the waters of the State other than from a discharge? ❑ Yes ❑ No ❑ NA ❑ NE ❑ Yes ,fNo ❑ NA ❑ NE ❑ Yes El"No ❑ NA ❑ NE Page 1 of 3 511212020 Continued Facility Number: - Date of Inspection: Waste Collection & Treatment 4. Is storage capacity (structural plus storm storage plus heavy rainfall) less than adequate? [:]Yes 0 No ❑ NA ❑ NE a. If yes, is waste level into the structural freeboard? ❑ Yes ❑ No ❑ NA ❑ NE Structure I Structure 2 Structure 3 Structure 4 Structure 5 Structure 6 Identifier: Spillway?: Designed Freeboard (in): Observed Freeboard (in): d� 5. Are there any immediate threats to the integrity of any of the structures observed? ❑ Yes [�J'No ❑ NA ❑ NE (i.e., large trees, severe erosion, seepage, etc.) 6. Are there structures on -site which are not properly addressed and/or managed through a ❑ Yes kfjNo ❑ NA ❑ NE waste management or closure plan? If any of questions 4-6 were answered yes, and the situation poses an immediate public health or environmental threat, notify DWR 7. Do any of the structures need maintenance or improvement? ❑ Yes [�No ❑ NA ❑ NE 8. Do any of the structures lack adequate markers as required by the permit? ❑ Yes 0No ❑ NA ❑ NE (not applicable to roofed pits, dry stacks, and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require [—]Yes ff No ❑ NA ❑ NE maintenance or improvement? Waste ADuiication 10. Are there any required buffers, setbacks, or compliance alternatives that need [:]Yes No ❑ NA ❑ NE maintenance or improvement? 11. Is there evidence of incorrect land application? If yes, check the appropriate box below. [] Yes ❑ No ❑ NA ❑ NE ❑ Excessive Ponding ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals (Cu, Zn, etc.) ❑ PAN ❑ PAN > 10% or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure/Sludge into Bare Soil ❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application Outside of Approved Area 12. Crop Type(s): 13. Soil Type(s): 14. Do the receiving crops differ from those designated in the CAWMP? [] Yes [2"No ❑ NA ❑ NE 15. Does the receiving crop and/or land application site need improvement? [] Yes �o ❑ NA ❑ NE 16. Did the facility fail to secure and/or operate per the irrigation design or wettable [] Yes [�r_No ❑ NA ❑ NE acres determination? 17. Does the facility lack adequate acreage for land application? [] Yes ffNo ❑ NA ❑ NE 18. is there a lack of properly operating waste application equipment? [] Yes ETNo ❑ NA ❑ NE Renuired Records & Documents 19. Did the facility fail to have the Certificate of Coverage & Permit readily available? [] Yes f] No ❑ NA ❑ NE 20. Does the facility fail to have all components of the CAWMP readily available? If yes, check [] Yes E] No ❑ NA ❑ NE the appropriate box. ❑WUP []Checklists ❑Design [:]Maps ❑ Lease Agreements ❑Other: 21. Does record keeping need improvement? If yes, check the appropriate box below. ❑ Yes ZI No ❑ NA ❑ NE ❑ Waste Application ❑ Weekly Freeboard ❑ Waste Analysis ❑ Soil Analysis ❑ Waste Transfers ❑ Weather Code ❑ Rainfall ❑Stocking []Crop Yield ❑ 120 Minute Inspections ❑ Monthly and 1" Rainfall Inspections ❑ Sludge Survey 22. Did the facility fail to install and maintain a rain gauge? ❑ Yes ❑ No ❑ NA ❑ NE 23. If selected, did the facility fail to install and maintain rainbreakers on irrigation equipment? [—]Yes �dNo ❑ NA ❑ NE Page 2 of 3 511212020 Continued Facility Number: - Date of Inspection. / 24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ Yes ZjNo ❑ NA ❑ NE 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check ❑ Yes ZfNo ❑ NA ❑ NE the appropriate box(es) below. ❑ Failure to complete annual sludge survey [:]Failure to develop a POA for sludge levels ❑ Non -compliant sludge levels in any lagoon List structure(s) and date of first survey indicating non-compliance: 26. Did the facility fail to provide documentation of an actively certified operator in charge? ❑ Yes ff No ❑ NA ❑ NE 27. Did the facility fail to secure a phosphorus loss assessments (PLAT) certification? ❑ Yes [�fNo ❑ NA ❑ NE Other Issues 2$. Did the facility fail to properly dispose of dead animals with 24 hours and/or document ❑ Yes [2 No ❑ NA ❑ NE and report mortality rates that were higher than normal? 29. At the time of the inspection did the facility pose an odor or air quality concern? ❑ Yes ❑ No ❑ NA ❑ NE If yes, contact a regional Air Quality representative immediately. 30. Did the facility fail to notify the Regional Office of emergency situations as required by the ❑ Yes [7No ❑ NA ❑ NE permit? (i.e., discharge, freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? if yes, check the appropriate box below. ❑ Yes [!� No ❑ NA ❑ NE ❑ Application Field ❑ Lagoon/Storage Pond ❑ Other: 32. Were any additional problems noted which cause non-compliance of the permit or CAWMP? ❑ Yes E ] No ❑ NA ❑ NE 33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative? ❑ Yes o ❑ NA ❑ NE 34. Does the facility require a follow-up visit by the same agency? ❑ Yes WNo ❑ NA ❑ NE Comments (refer to question #): Explain any YES answers and/or any additional recommendations or any other comments. Use drawings of facility to better explain situations (use additional pages as necessary). co po11a 93 ,j G� TIC Cc�c-s s10,5'7 0-13- Lo�30$3 LcL�� L43) n.7= a,9�5 L;#+���� 0, y 7 a - 1,4 a3 L.aa 9'T(o-6 11-6- aaa3 / 03 5.1 uzL&2 o -� s, '7 ► PZ 1,-1, 0 g o = a , til I T= :5 , a- t p4 C4 3 109- = 00OLf 9lp07.e, Reviewedlnspector Name: +r1 Reviewer/Inspector Signature: Page 3 of 3 0 Phone: 91 19I "�a Date: 5112,12020