Loading...
HomeMy WebLinkAboutNC0073814_Wasteload Allocation_19950113#14 Facility Name: NPDES No.: Type of Waste: Facility Status: Permit Status: Receiving Stream: Stream Classification: Subbasin: County: Regional Offioe: Requestor: Date of Request: Topo Quad: North Buncombe Elementary School NGGG738044 NCoo 'f301�i 100 % Domestic Existing Renewal Dick Branch C 04-03-02 Buncombe Asheville Alvarez 1 /13/95 E8NE Staff Report: x IWC Spreadsheet: Stream Classification: Instream Data: nr Request # B8184 Stream Characteristic: USGS # Date: Drainage Area (miz): 2.27 Summer 7010 (cfs): 0.14 Winter 7010 (cfs): 0.27 Average Flow (cfs): 2.3 3002 Ids): IWC (%): 10.8% Modeled w/ Secondary limits recommended for discharges of 0.011 and 0.018 mgd in 1988. Streamlined 1993, (w/ WIA form filled out). Note on WLA indicates that DMR data may be too good for this type of system.... DMR,s VERY good effleunt data I will recommend Instream monitoring due to cluster of dischargers. Upstream: SR 1764 - ap3w-u, oN U,cK 6g�,M Pb„c Downstream: ar SR 1738-CortptyG.4C a Ct Rno.crti GO N£�uFNCE 1tAWRE.IC' NA0,1CO tJ.V,ej� nr. BwJw►,e n. alp FhT tact � �" Facility needs to choose between ammonia limit and toxi .Ily 'rku tJd( �Ap{ Ammonia as NH3 C'P�ts OP 6vt�Iv, Bvaco. ek:�; Residual Chlorine (summer) F-k,-. qnb 4. 5 •) 7Q10 (cfs) 0.14 0.14 7Q10 (cfs) Design Flow (mgd) 0.011 0.011 Design Flow (mgd) Design Flow (cfs) 0.017 0.017 Design Flow (cfs) Stream Std (µg/I) 17 1 Stream Std (mg/1) Upstream bkgrd level (µgA) 0 0.22 Upstream bkgrd level (mg/1) IWC (%) 10.8% 10.8% IWC (%) Allowable Concentration (µg1l) 157.0 7.4 Allowable Concentration (mg/I) Allowable Concentration (mg/1) 0.157 Ammonia as NH3 (winter) 0.27 7Q10 (cfs) 0.011 Design Flow (mgd) Fecal Limit 200/100ml 0.017 Design Flow (cfs) Ratio of 8 :1 1.8 Stream Std (mgA) 0.22 Upstream bkgrd level (mg/I) 5.9% IWC (%) 26.9 Allowable Concentration (mg/1) Email Response from Max Haner NCO073814 1992 Staff Report indicated that a suit was filed due to proximity of discharge gto nearby dwelling.... whatever happened? Response: The case was BICKFORD V. BUNCOMBE COUNTY BOARD OF EDUCATION and was settled out of court on February 8, 1993 (terms of settlement unknown). The suit was based on damage to residential property across road from WWTP which was constructed 122.8 ft from dwelling (.0200 WQ Regs require minimum separation of too ft). Noise and TV reception problems caused by WWTP operation upset owner. School Board tried to satisfy owner by providing visual barrier and muffling noise from blowers. Problems reported still noticeable in quiet of night. Home owner moved to Wyoming prior to 1993. Thanks for the opportunity to comment. Sru'r� l [3l 9s B A. (). EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS FINAL During the period beginning on the effective date of the permit and lastinguntil expiration, Permit No. NC0073814 outfall(s) serial number 001. Such discharges shall be limited and monitored piratzon, the Permittee is authorized to discharge from by the permittee as specified below: Flow BOD, 5 day, 200C Total Suspended Residue NH3 as N Fecal Coliform (geometric mean) Total Residual Chlorine Temperature DIacharyie _Llmitatlon� WAek_ly An. Daily Max 0.011 MGD 30.0 mg/I 45.0 mg/I 30.0 mg/I 45.0 mg/I 200.0 /100 ml 400.0 /100 ' ml aun►m�2. 4Mr»aw? Iq = 'T.4 rVq w�nitc-mot_ 'Zv- .aN►/D : t6.0k Mo Itorin Re ul eme is Measurennent Sa_egle •S Frequency TyR arnpie t_o__ c@tlon Weekly Instantaneous I or E 2/Month Grab E 2/Month Grab E Monthly Grab E 2/Month Grab E Weekly Grab E Daily Grab E * Sample locations; E -Effluent I -Influent The pH shall not be less than 6.0 standarr units nor greater than • sample. 9.0 standard units and shall be monitored 2/month at the effluent by grab There shall be no discharge of floating solids or visible foam in other than trace amounts. 6 in 41(14vt Z) -SOC PRIORITY PROJECT: IF YES, SOC NUMBER TO: PERMITS AND ENGINEERING UNIT WATER QUALITY SECTION ATTENTION: SUSAN WILSON 1 DATE: October 5, 1994 NPDES STAFF REPORT AND RECOAD4ENDATION COUNTY Buncombe PERMIT NUMBER NCO073814 PART I - GENERAL INFORMATION No 1. Facility and Address: North Buncombe Elementary School 251 Flat Creek Church Road Weaverville, North Carolina 28787 Mailing Address: 175 Bingham Road Asheville, North Carolina 28806 2. Date of Investigation: March 15, 1994 3. Report Prepared By: Max L. Haner _. Persons Contacted and Telephone Number: 5. Directions to Site: Existing facility is located adjacent to NCSR 1764 (Flat Creek Church Road) approximately 0.2 mile west of its intersection with NCSR 1737 near Weaverville, N.C. in Buncombe County. 6. Discharge Point(s), List for all discharge points: Latitude: 350 44' 20" Longitude: 820 35' 23" Attach a USGS map extract and indicate treatment facility site and discharge point on map. U.S.G.S. Quad No. E8NE U.S.G.S. Quad Name Weaverville, N.C. Page 1 7. Site size and expansion area consistent with application? XXX_ Yes No If No, explain: 8. Topography (relationship to flood plain included): Not in Flood Plain 9. Location of nearest dwelling: Nearest dwelling is located approximately 122.8 feet south of the treatment facility on the opposite side of Flat Creek Church Road. 10. Receiving stream or affected surface waters: Dick Branch a. Classification: Class "C" b. River Basin and Subbasin No.: French Broad / 040302 C. Describe receiving stream features and pertinent downstream uses: Wildlife and Agriculture PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. a. Volume of wastewater to be permitted 0.011MGD (Ultimate Design Capacity) b. What is the current permitted capacity of the Wastewater Treatment facility? 0.011 MGD C. Actual treatment capacity of the current facility (current design capacity 0.011 MGD d. Date(s) and construction activities allowed by previous Authorizations to Construct issued in the previous two years: N/A e. Please provide a description of-v,'G*ing or sub---,+4 ,11y constructed wastewater treatment facilities: Existing facility is an 11,000 gpd extended aeration type wastewater treatment system with flow equalization (surge tank), grease -removal (dual grease traps at school cafeteria), aerated sludge holding, and effluent disinfection (tablet type chlorination) and approximately 6000 L.F. of 3-inch outfall to Dick Branch. f. Please provide a description of proposed wastewater treatment facilities: g. Possible toxic impacts to surface waters: h. Pretreatment Program (POTWs only): in development approved should be required not needed Page 2 2. Residuals handling and utilization/disposal scheme: Sludge holding with arrangement with MSD of Buncombe County WWTP for final disposal. a. If residuals are being land applied, please specify DEM Permit Number Residuals Contractor Telephone Number b. Residuals stabilization: PSRP PFRP OTHER C. Landfill: d. Other disposal/utilization scheme (Specify): 3. Treatment plant classification (attach completed rating sheet): II 4. SIC Codes(s): 4952 Wastewater Code(s) of actual wastewater, not particular facilities i.e., non - contact cooling water discharge from a metal plating company would be 14, not 56. Primary 03 Secondary If Main Treatment Unit Code: 06007 PART III - OTHER PERTINENT INFORMATION 1. Is this facility being constructed with Construction Grant Funds or are any public monies involved. (municipals only)? 2. Special monitoring or limitations (including toxicity) requests: None 3. Important SOC, JOC, or Compliance Schedule dates: (Please indicate) Date Submission of Plans and Specifications Begin Construction Complete Construction Page 3 4. Alternative Analysis Evaluation: Has the facility evaluated all of the non - discharge options available. Please provide regional perspective for each option evaluated. Spray Irrigation: Connection to Regional Sewer System: Rural location prohibitive. Subsurface: On -site disposal evaluated with initial application and found unsupportable. Other disposal options: 5. Other Special Items: PART IV - EVALUATION AND The existing facility has demonstrated capability to produce an effluent in compliance with effluent limitations contained in the permit. It is recommended that the permit renewal request proceed to public notice and be issued as appropriate. L SignaYJY�_ t, . ture of Report Preparer Y Supe_---.-c_ Date Page 4