Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0045304_Application (FTSE)_20240416
STRONGROCK STRONGROCK ENGINEERING GROUP, PLLC P.O. Box 99552 9552 Raleigh, NC 27624 E N G I N E E R I N G G R G u P ` ���D, f� !\� Company License # P-2166 \VAS (.� U V RECEIVED/NCDENR/DWR TRANSMITTAL FORM TO: NCDEQ Division of Water Resources —Wilmington Regional Office Water Quality Section APR 16 2024 943 Washington Square Mall Water Quality Washington, NC 27889 Regional Ope•ations Section Washington Regional Office SUBJECT: La Grange Perry 2 Fast Track Sewer #WQ0045259 DATE: April 15, 2024 SENT BY: Sara Rogan We are sending you the following items: COPIES ITEM DESCRIPTION 1 Application Fast Track Sewer form signed by Town of LaGrange ORIG I NAL 1 Flow tracking Flow tracking form filled out by Town of La Grange ORIGINAL These are transmitted as checked below: _ For Information _ Approved as Noted — Revise and Resubmit _ As Requested Not Approved — Revise and Resubmit X For Review and Comments _ For Record and File _ For Revision _ Submittal For Approval For Recording Approved For Signature, then return to: REMARKS: Originally signed application and FTSE for La Grange Perry 2 Fast Track Sewer, initial package was received by 3/13/24, review is Sarah Toppen STRONGR4CK E N G I N E E R I N G G R O U P TRANSMITTAL FORM STRONGROCK ENGINEERING GROUP, PLLC P.O. Box 99552 Raleigh, NC 27624 Company License # P-2166 TO: NCDEQ Division of Water Resources —Wilmington Regional Office Water Quality Section 943 Washington Square Mall Washington, NC 27889 SUBJECT: La Grange Perry 2 Fast Track Sewer Initial Submittal DATE: Martha,', 2024 SENT BY: Sara Rogan We are sending you the following items: COPIES 1 Check I $600 check N1144 DESCRIPTION 2 _ 1 Application I Fast Track Sewer form signed by Town of La Grange 2 Flowtracking I Flow tracking form filled out by Town of La Grange Site Map USGS topo map with site highlighted 1 Narrative 2 Operational Agreement Engineering narrative RECEIVED/NCDENR/DWR MAR 2 5 2024 Water Quality Regional Operations Section Washington Regional Office Operation agreement execute by developer — Ellis Developments NC, LLC These are transmitted as checked below: For Information _ Approved as Noted — Revise and Resubmit As Requested _ Not Approved — Revise and Resubmit X For Review and Comments _ For Record and File _ For Revision _ Submittal For Approval _ For Recording Approved _ For Signature, then return to: REMARKS: 1�j rrQ( c� 3�-z' STRONGROCK C ., I '! - C I I .. P i. .. 03/12/2024 North Carolina Department of Environmental Quality Division Of Water Resources RE: La Grange Tract 2 — Fast Tract Sewer Submittal Dear NCDEQ: Division of Water Resources, STRONGROCK ENGINEERING GROUP, PLLC 8362 Six Forks Rd. Suite 104 RECENED/NCDEN R/DWRRaleigh, NC 27615 Company License # P-2166 MAR 2 5 2024 Water Quality Regional Operations Section Washington Regional Office This application is being submitted for review for a proposed 89-lot residential subdivision consisting of single family dwellings. This project is located in La Gange, North Carolina within Lenior County off of Lake Pine Drive near the intersection of South Charles Street. This subdivision is to be served via 8-inch diameter PVC gravity sanitary sewer systems, connecting to existing gravity sewer at the entrances of the proposed residential subdivision. The demand for this subdivision is calculated to be 20,025 GPD using 75 gallons per bedroom per lot. Please let me know if you have any further questions. Take care, Christopher Stone Engineering Team Lead Strong Rock Engineering Group, PLLC ® The Applicant's Certification on Page 5 of the application shall be signed in accordance with IS A NCAC 021 .01061 b 1. Per 15A NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation letter is provided from a person who meets the criteria in I5A NCAC 02T .0106(b). V45CFNEDINCOENTV"--_ g -k 5 2�24 State of North Carolina DWR Department of Environmental Quality Water r [ section Division of Water Resources Regional OPe nat 0" W p. 4t4l'�ii UCK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources INSTRUCTIONS FOR FORM: FTA 10-23 & SUPPORTING DOCUMENTATION This application is for sewer extensions involving gravity sewers, pump stations and force mains, or any combination that has been certified by a professional engineer and the applicant that the project meets the requirements of 15A NCAC 02T and the Division's Minimum Design Criteria (Gravity Sewer & Pump Stations/Force Mains) and that plans, specifications and supporting documents have been prepared in accordance with 15A NCAC 02T. 15.A NCAC 02T.030t6 Division policies, and good engineering Practices. While no upfront engineering design documents are required for submittal, in accordance with 15A NCAC 02T .0305(b), design documents must be prepared prior to submittal of a fast track permit application to the Division. This would include plans, design calculations, and project specifications referenced in IS.A NCAC 02T .0305 and the applicable minimum design criteria. These documents shall be immediately available upon request by the Division. Projects that are deemed permitted (do not require a permit from the Division) are explained in 15A NCAC 02T.0303. Projects not eligible for review via the fast track process (must be submitted for full technical review): > Projects that do not meet any part of the minimum design criteria (MDC) documents; > Projects that involve more than one variance from the requirements of 15A NCAC 02T; > Pressure sewer systems utilizing simplex septic tank -effluent pumps (STEPs) or simplex grinder pumps; > Simplex STEP or simplex grinder pumps connecting to pressurized systems (e.g, force mains); > Vacuum sewer systems. General — When submitting an application, please use the following instructions as a checklist in order to ensure all required items are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and reduce the amount of requested additional information. Failure to submit all required items will necessitate additional processing and review time, and may result in return of the application. Unless otherwise noted, the Applicant shall submit one original and one copy of the application and supporting documentation. A. One Original and One Copy (second copy may be digital) of Application and Supporting Documents ® Required unless otherwise noted. Signatures on original must be "wet ink" or secure digital signatures. Please do not submit engineering design plans with the application unless specifically requested. B. Cover Letter/Narrative Description (Required for All Application Packages): ® List all items included in the application package, as well as a brief description of the requested permitting action. > Be specific as to the system type, number of homes served, flow allocation required etc. > Include the permit number/status of any other required sewer permits (downstream/upstream) > If necessary for clarity, include attachments to the application form. > If the project is funded by American Rescue Plan Act (ARPA) funds, please include the ARPA project number in the cover letter and in parentheses under Project Name (Section 11.1. of the application). C. Application Fee (All New and Modification Application Packages): ® Submit a check or money order in the amount of $600.00, dated no more than 90 days prior to application submittal. > Payable to North Carolina Department of Environmental Quality (NCDEQ) D. Fast Track Application (Required for All Application Packages, Form FTA 10-23): ® Submit the completed and appropriately executed application. > If necessary for clarity or due to space restrictions. attachments to the application may be made. ® If the Applicant Type in Item 1.2 is a corporation or company, provide documentation it is registered for business with the North Carolina Secretary of State. ❑ If the Applicant Type in Item 1.2 is a partnership or d/b/a, enclose a copy of the certificate filed with the Register of Deeds in the county of business. ® The Project Name in Item ILI shall be consistent with the project name on the flow acceptance letters, agreements, etc. ® The Professional Engineer's Certification on Page 5 of the application shall be signed, sealed and dated by a North Carolina licensed Professional Engineer. INSTRUCTIONS FOR FORM: FTA 10-23 & SUPPORTING DOCUMENTATION Page I of 3 THE COMPLETED APPLICATION PACKAGE IIVCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 2090 US Highway 70 Avery, Buncombe, Burke, Caldwell, Cherokee, Water Quality Section Swannanoa, North Carolina 28778-8211 Clay, Graham, Haywood, Henderson, Jackson, (828) 296-4500 Macon, Madison, McDowell, Mitchell, Polk, (828) 299-7043 Fax Rutherford, Swain, Transylvania, Yancey Fayetteville Regional Office 225 Green Street Suite 714 Anson, Bladen, Cumberland, Harnett, Hoke, Water Quality Section Fayetteville, North Carolina 28301-5095 Montgomery, Moore, Robeson, Richmond, (910) 433-3300 Sampson, Scotland (910) 486-0707 Fax Mooresville Regional Office 610 E. Center Avenue Alexander, Cabarrus, Catawba, Cleveland, Water Quality Section Mooresville, North Carolina 28115 Gaston, Iredell, Lincoln, Mecklenburg, Rowan, (704) 663-1699 Stanly, Union (704) 663-6040 Fax Raleigh Regional Office 3800 Barrett Drive Chatham, Durham, Edgecombe, Franklin, Water Quality Section Raleigh, North Carolina 27609 Granville, Halifax, Johnston, Lee, Nash, (919) 791-4200 Northampton, Orange, Person, Vance, Wake, (919) 571-4718 Fax Warren, Wilson Washington Regional Office 943 Washington Square Mall Beaufort, Bertie, Camden, Chowan, Craven, Water Quality Section Washington, North Carolina 27889 Currituck, Dare, Gates, Greene, Hertford, Hyde, (252) 946-6481 Jones, Lenoir, Martin, Pamlico, Pasquotank, (252) 975-3716 Fax Perquimans, Pitt, Tyrrell, Washington, Wayne Wilmington Regional Office 127 Cardinal Drive Extension Brunswick, Carteret, Columbus, Duplin, New Water Quality Section Wilmington, North Carolina 28405 Hanover, Onslow, Pander (910)796-7215 (910)350-2004 Fax Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Alamance, Allegheny, Ashe, Caswell, Davidson, Davie, Forsyth, Guilford, Rockingham, Randolph, Water Quality Section Winston-Salem, North Carolina 27105 Stokes, Surry, Watauga, Wilkes, Yadkin (336)776-9800 (336) 776.9797 Fax INSTRUCTIONS FOR FORM: FTA 10-23 & SUPPORTING DOCUMENTATION Page 3 of Division of Water Resources & O 3 O � State of North Carolina Department of Environmental Quality Division of Water Resources Application Number: FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 10-23 & SUPPORTING DOCUMENTATION (to be completed by DWR) All items must be completed or the application will be returned 1. APPLICANT INFORMATION: I. Applicant's name: TOWN OF LA GRANGE (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's name: SHAWN CONDON per 15A NC\C 02T .0106(b) Title: TOWN MANAGER 4. Applicant's mailing address: 203 S. CENTER ST City: LA GRANGE State: NC Zip: 28551- 5. Applicant's contact information: Phone number: (252) 566-3186 Email Address: smcondonAlaurangenc.com 11. PROJECT INFORMATION: 1. Project name: LA GRANGER PERRY TRACT 2 2. ApplicationTroject status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: W000_ and issued date: , ❑ ARPA funded For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number. W000_ 3. County where project is located: LENOIR / 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.297571' Longitude:-77.794338°v 5. Parcel ID (if applicable): 355616948861 (or Parcel ID to closest downstream sewer) 111. CONSULTANT INFORMATION: / I. Professional Engineer: JOSH LAMBERT License Number: 036225V Firm: STRONG ROCK ENGINEERING GROUP Mailing address: 305 CHURCH AT NORTH HILLS ST. STE. 1110 City: RALEIGH State: NC Zip: 27609 Phone number. 9(� 200-1932 Email Address: INFORMATIONna STRONGROCKGROURCOM IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Town of La Grange Permit Number: NCO021644 Owner Name: Town of La Grange V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. PermitNumber(s): WQ_ 2. Downstream (Receiving) Sewer Information: 8 inch ❑ Gravity ❑ Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS 00148 Owner Name(s): Town of La Grange FORM: FTA 10-23 Page I of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility. has a Certificate of Public Convenience and Necessity been attached? ❑ Yes []No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement ( FORM: DEV I been attached? ❑ Yes ❑ No ® N/A 3. If the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational Agreement (FORM: HOA) and supplementary documentation as required by 15A NCAC 02T.0115(c) been attached? ❑ Yes ❑ No ® N/A 4. Origin of wastewater: (check all that apply): ® Residential (Individually Owned) ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential (Leased) ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool/Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater : 100 % Domestic % Commercial _ % Industrial (See 15A NCAC 02T .0103(20)) If Industrial, is there a Pretreatment Program in effect? ❑ Yes❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .01 14(T. ❑ Yes ®No i If yes, provide a copy of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow'" No. of units Flow Residential Subdivision u- ti 75 gal/bed/day 89 20025 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 20025 GPD t/ a See 15A \CAC 021 .0114(b). (d). (e)( I ) and (e)(2) for caveats to wastewater design flow rates (i.e. proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T.0114(c), design flow rates for establishments not identified [in table I5A NCAC 02T.0114 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 20025 GPD (per 15A NCAC 02T .0114 and G.S. 143-215.1) Do not include future flows or previously permitted allocations If permitted flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: Issuance Date: _ ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 10-23 Page 2 of 5 VIL GRAVITY SEWER DESIGN CRITERIA (If Applicable)-02T.0305&i1DC(Gravity Sewers): I. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8" 5111 ft C900 PVC Section 11 & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria > Section III contains information related to minimum slopes for gravity sewer(s) > Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable)-02T.0305 & MDC (Pump Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT I. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Total number of pumps at the pump station: 3. Design flow of the pump station: _ millions gallons per day (firth capacity) > This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): _ gallons per minute (GPM) at _ feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01 C. Lb. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) _ 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or ❑ Standby pump > Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B).* > Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day > Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 10-23 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B.0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations/altematives found in 15A NCAC 02T.0305(f) & NV ® Yes ❑ No 15A NCAC 02T.0305 contains minimum separations that shall be provided for sewers stems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 18 inches 'Water mains (vertical - water over sewer preferred, including in benched trenches) 18 inches =Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet "Any private or public water supply source, including any wells, WS-1 waters of Class 1 or Class 11 impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet "Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches > If noncompliance with 02T.0305(f) or (2). see Section X.l of this application `15A NCAC 02T.0305(e) contains alternatives where separations in 02"1.0305(f) cannot be achieved. Please check "yes' above if these alternatives are used and provide narrative information to explain. "Stream classifications can be identified using the Division's NC Surface Water Classifications weboage 2. Does this project comply with the minimum separation requirements for water mains? ® Yes ❑ No ❑ N/A S If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ❑ Yes ❑ No ® N/A > Please provide supplementary information identifying the areas of non-conformance. > Seethe Division's draft separation reuuirements for situations where separation cannot be met. > No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ❑ Yes Basin name: _ ® No If yes, does the project comply with setbacks found in the river basin rules per I SA NCAC 02B .0200? ❑ Yes ❑ No > This includes Trout Buffered Streams per 15A NCAC 2B.0202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑ Yes ® No or 401 Water Quality Certifications? > Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15A NCAC 02T.0 I 05(c)(6) (additional permits/certifications)? ® Yes ❑ No Per I5A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No Per 15A NCAC 02T.0402, "high -priority sewer' means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. > If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 10-23 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If no, for projects requiring a single variance, complete and submit the Variance/Altemative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued concurrently with the approval of the permit, and projects requiring a variance approval may be subject to longer review times. For proiccts requiring two or more variances or where the variance is determined by the Division to be a significant portion of the proiect, the full technical review is required. 2. Professional Engineers Certification: 1 Josh Lambert , attest that this application for La Grange Perry Tract 2 (Professional Engineer's name from Application Item III I (Project Name from Application Item 11.1) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteria for Gravity Sewers (latest t ersion), and the %linimum Design Criteria for the First- 1-rack Permitting of Pump Stations and Force plains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701) North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): 1, .SAAvirk `onWon attest that this application for `a G'�a�5e Pryy 6,J 2 (Signature Auihorin Name from Application Item 13) IPrnicn \amc I' Am�n Item 11.1) attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. 1 will make no claim against the Division of Water Resources should a condition of this permit be violated. 1 also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.661 any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S 10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: 3 2/ 20 y I Or FORM: FTA 10-23 Page 5 of 5 Gor',gle MapS Lake Pine Estates (La Grange Perry Tract 2) Imagery ©2024 Airbus, Maxar Technologies, U.S. Geological Survey, USDA/FPAC/GEO, Map data ©2024 500 ft itECEWED/NCDENFVDWR APR 16 2024 State of North Carolina DWRDepartment of Environmental Quality Water ation y Division of Water Resources Fegiorrel Opc�ations Sectior� Washington Flamonai 'c Division of Water Resources Flow 'making for Sewer Extension Applications (FTSE 10-23) Entity Requesting Allocation: Ellis Development NC LLC Project Name for which flow is being requested: Ellis -LaGrange -Perry More than one FTSE maybe required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewaterJlow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: LaGrange Wastewater Treatment Plant b. WWTP Facility Permit #: NCO021644 AU lows are in MGD c. WWTP facility's permitted flow 0.7S d. Estimated obligated flow not yet tributary to the WWTP 0.00 e. WWTP facility's actual avg. flow 0.46 f. Total flow for this specific request 0.02 g. Total actual and obligated flows to the facility 0.48 h. Percent of permitted flow used 64% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Finn Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm / pf), Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** Lake Pines 0.2592 0.10368 0.0576 0 0.0576 0.04608 --;The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pt) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Downstream Permit Number: La Grange WWTP NCO021644 Page 1 of 6 FTSE 10-23 III. Certification Statement: I Shawn Condon certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Signing Official Signature Twn M4A f.Jrr Title of Signing Official Page 2 of 6 FTSE 10-23 Average Yearly Flow for: Jan.2023 Feb.2023 Mar.2023 Apr.2023 May2023 Jun2023 Ju12023 Aug2023 Sept2023 Oct2023 Nov2023 Dec2023 Town of La Grange, NCO021644 Permitted Flow: 0.2469677 0.3767857 0.2765807 0.3785 0.3035807 0.2703667 0.3698387 0.2723548 0.3371667 0.2730968 0.2438333 0.3461613 0.307936092 Avg. Flow 2023 % of Permitted Flow: 0.75 0.410581456 (< 80%/ 90% 0K)