Loading...
HomeMy WebLinkAboutNC0074772_Staff Report_19941117L SOC PRIORITY PP,O = : No To: Permits and Engineering Unit Water Quality Section Attention: Susan Robson Date: November 17, 1994 NPDES STAFF REPORT AND RECOMMENDATIONS County: Iredell NPDES Permit No.: NC0074772 MRO No.: 94-224 PART I - GENERAL INFORMATION 1. Facility and Address: Diamond Head Development c/o Mid South Water Systems, Inc. Post Office Box 127 Sherrills Ford, N.C. 28673 2. Date of Investigation: November 16, 1994 3. Report Prepared By: Michael L. Parker, Environ. Engr. II 4. Person Contacted and Telephone Number: Neil Cantor, (704) 478-2785. 5. Directions to Site: From the jct. of I-77 and SR 1109 (Williamson Road) south of the Town of Mooresville, travel northwest on SR 1109 x 0.4 mile. The Diamond Head site is located on the right (east) side of SR 1109. 6. Discharge Point(s), List for all discharge Points: - Latitude: 35' 33' 53" Longitude: 80° 51' 58" Attach a USGS Map Extract and indicate treatment plant site and discharge point on map. USGS Quad No.: E 15 SE 7. Site size and expansion area consistent with application: Yes. The applicant has applied for an expansion up to 0.100 MGD. This expansion will utilize all available area set aside for future WWTP expansion. 8. Topography (relationship to flood plain included): Rolling topography, slopes 5-15%. The site is located well above the full pond elevation of Lake Norman. 9. Location of Nearest Dwelling: Presently, 300+ feet from the WWTP. Proposed dwellings are projected to be constructed within 150 feet of the WWTP. i Page Two 10. Receiving Stream or Affected Surface Waters: Catawba Riv=r (Lake Norman) a. Classification: WS-IV and B b. River Basin and Subbasin No.: Catawba 030832 C. Describe receiving stream features and pertinent downstream uses: The discharge enters Lake Norman in the Reeds Creek area. There are no other known dischargers in the immediate area, however, there is a non -potable industrial water intake located x 0.25 mile downstream. The lake receives considerable bodily contact as a result of primary recreational activities. PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. a. Volume of Wastewater: 0.033 MGD (Design Capacity) b. What is the current permitted capacity: 0.100 MGD C. Actual treatment capacity of current facility (current design capacity): 0.033 MGD d. Date(s) and construction activities allowed by previous ATCs issued in the previous two years: No recent construction activities, however, an expansion from 0.033 to 0.100 MGD has been approved (ATC issued 8-22- 94). e. Description of existing or substantially constructed WWT facilities: The existing WWT facilities consist of an influent bar screen followed by a V-notch weir, dual flow equalization tanks, dual aeration basins, dual clarifiers, a multi -media tertiary filter, a chlorine contact tank with tablet disinfection, an aerated sludge holding tank, post aeration, a sonic flow meter, an effluent pump station and stand-by power. f. Description of proposed WWT facilities: The applicant proposes to construct two (2) identical 0.033 MGD WWTPs having the same treatment processes as listed in (e) above including dechlorination. g. Possible toxic impacts to surface waters: Chlorine is added to the waste stream, however, the addition of dechlorination should minimize toxicity concerns. h. Pretreatment Program (POTWs only): Not Needed. Residual handling and utilization/disposal scheme: Residuals are removed by Roberts Septic Tank Service and are disposed of in the City of Hickory's sewer collection system. Treatment Plant Classification: Less than 5 points; no rating (include rating sheet). Class II (presently) This facility will go to Class III upon expansion to 0.100 MGD and the addition of dechlorination facilities. Page Three 4. SIC Code(s): 4952 Wastewater Code(s): 05 5. MTU Code(s): 06107 ]ART III - OTHER PERTINENT INFORMATION 1. Is this facility being constructed with Construction Grant Funds or are any public monies involved (municipals only)? No 2. Special monitoring or limitations (including toxicity) requests: None at this time. 3. Important SOC/JOC or Compliance Schedule dates: N/A 4. Alternative Analysis Evaluation a. Spray Irrigation: N/A b. Connect to regional sewer system: None available to the site. C. Subsurface: Insufficient area. PART IV - EVALUATION AND RECOMMENDATIONS The applicant, Mid South Water Systems, requests reissuance of the subject Permit. The only changes/modifications to the Permit necessary at this time is the addition of effluent limitation pages for 0.033 MGD (current plant capacity) and 0.100 MGD (proposed expansion). The compliance screen should be updated from the current hydraulic flow of 0.100 MGD to 0.033 MGD. It should also be noted that the facility's classification will go from a Class II to a Class III upon expansion to 0.100 MGD. Pending receipt and approval of the WLA, it is recommended that the Permit be renewed as requested. C Signature of Report Preparer Date Z), /?, , , , e,- -, , //// Water QualityLolkegional Su ervisor Dat p:\dsr\dsr94\diamond.sr