Loading...
HomeMy WebLinkAboutNC0074772_Authorization to Construct_19940822State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director. August 22, 1994 Mr. Carroll Weber Mid South Water Systems, Incorporated P.O. Box 127 Sherrills Ford, NC 28673 WA AdEMOdOMENO& IL E)EHNR Subject: Permit No. NCO074772 Authorization to Construct Mid South Water Systems Diamond Head Subdivision Wastewater Treatment Facility Iredell County Dear Mr. Weber: A letter of request for an Authorization to Construct was received February 8, 1994 by the Division and final plans and specifications for the subject project have been reviewed and found to be satisfactory. Authorization is hereby granted for the construction and operation of a 73,100 gpd expansion for a total wastewater treatment capacity of 100,000 gpd. The expansion consists of a 5.6 sf bar screen, 12,000 gpd flow equalization basin with 70 cfm blower at 5 psi and dual 100 gpm submersible flow equalization pumps; flow control chamber with weirs to split flow three ways - 26,900 gpd to the existing plant area, (2) 36,550 gpd outlets to the proposed dual package plants;' dual 48,600 gallon aeration basins (97,200 gallons total); 2 dual hopper type clarifiers each being 10 feet x 10 feet, four 3 inch sludge return airlifts, 4 airlift skimming devices; 2 centrifugal blowers (for noise reduction) rated at 530 CFM each at 5 psi; 6900 gallon sludge holding tank; 2384 gallon chlorine contact tank with split flow dual tablet chlorination; 5454 gallon clear well with two backwash pumps to deliver 15 gpm/square foot, two tertiary fillers with a total surface area of 69 sf, a 55 cfm blower, a 5744 gallon mudwell with dual 40 gpm pumps and 2 inch mudwell line to flow equalization basin, a 1552 gallon post aeration chamber with 2 split flow tablet dechlorinators, standby generator, and all the associated valves, piping, and appurtenances with discharge of treated wastewater into Lake Norman which is classified Class WS-III&B waters. This Authorization to Construct is issued in accordance with Part III, Paragraph A of NPDES Permit No. NCO074772 issued February 15, 1993, and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in Permit No. NC0074772. The sludge generated from these treatment facilities must be disposed of in accordance with G.S. 143-215.1 and in a manner approved by the North Carolina Division of Environmental Management. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement wastewater treatment or disposal facilities. P.O. Box 29535, Raleigh, North Carolina 27626-0535- Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper Permit No. NC0074772 Authorization to Construct Mid. South Water Systems Diamond Head Subdivision August 22, 1994 Page 2 The Mooresville Regional Office, telephone number (704) 663-1699, shall be notified at least forty-eight (48) hours in advance of operation of the installed facilities so that an in -place inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the NPDES Permit, this Authorization to Construct and the approved plans and specifications. Mail the Certification to the Permits and Engineering Unit, P.O. Box 29535, Raleigh, NC 27626-0535. Upon classification of the facility by the Certification Commission, the Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of the wastewater treatment facilities. The operator must hold a certificate of the type and grade at least equivalent to or greater than the classification assigned to the wastewater treatment facilities by the Certification Commission. The Permittee must also employ a certified back-up operator of the appropriate type and grade to comply with the conditions of Title 15A, Chapter 8A, .0202. The ORC of the facility must visit each Class I facility at least weekly and each Class II, III, and IV facility at least daily, excluding weekends and holidays, and must properly manage and document daily operation and maintenance of the facility and must comply with all other conditions of Title 15A, Chapter 8A, .0202. Once the facility is classified, the Permittee must submit a letter to the Certification Commission which designates the operator in responsible charge within thirty days after the wastewater treatment facilities are 50% complete. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the facility. Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division of Environmental Management in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. The issuance of this Authorization to Construct does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. One (1) set of approved plans and specifications is being forwarded to you. If you have any questions or need additional information, please contact Susan A. Wilson, telephone number 919/733- 5083. Sincerely, Preston o ard, Jr., P.E. cc: Iredell County Health Department Mooresville Regional Office, Water Quality Training and Certification Unit Dale Stewart, Land Design Engineering Services SOC PRIORITY PROJECT: No To: Permits and Engineering Unit Water Quality Section Attention: Susan Wilson Date: March 7, 1994' AUTHORIZATION TO CONSTRUCT NPDES PERMIT F�� $ jgC� REPORT AND RECOMMENDATIONS County: Iredelli>� st'ffr�. MRO No.: 94-50 Permit No. NC007477' _.... PART I - GENERAL INFORMATION 1. Facility and Address: Diamond Head WWTP c/o Mid South Water Systems, Inc. Post Office Box 127 Sherrills Ford, N.C. 28573 2. Date of On -Site Investigation (if conducted): N/A 3. Report Prepared By: Michael L. Parker, Environ. Engr. II 4. Persons Contacted and Telephone Number: Dale Stewart, P.E., (704) 376-7777. 5. Verified Discharge Point(s), List for All Discharge Points: Latitude: 35" 33' 53" Longitude: 80° 51' 58" Attach a USGS map extract and indicate treatment facility site and discharge point on map. Ensure discharge point(s) correspond to NPDES permitted discharge points. USGS Quad No.: E 15 SE G. Site size and expansion area consistent with application? Yes. There is ample area available for the proposed WWTP expansion. 7. Topography (relationship to flood plain included): Hill.., 5-12% slopes. The site is not in a flood plain. 8. Location of Nearest Dwelling: None within 500 feet of the WWTP site. Page Two PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS I. Existing Treatment Facility a. Current permitted capacity: 0.100 MGD. b. Date(s) and construction activities allowed by previous ATCs issued in the previous two (2) years: N/A. C. Actual treatment capacity of the current facility (design volume): 0.0334 MGD. d. Description of existing or substantially constructed WWT facilities: an influent bar screen followed by a V- notch weir, dual flow equalization basins, dual aeration basins, dual secondary clarifiers, an aerated sludge holding tank, a tertiary filter, a chlorine contact tank with tablet disinfection, a flow measuring device, post aeration, effluent pump station and stand- by power. 2. Type of Proposed Treatment Facility: The applicant proposes to construct two (2) identical 0.333 activated sludge WWTPs having the same treatment units as the existing facilities identified in No. 1(d) above with the exception of dechlorination which will be added. 3. Residuals Handling and Utilization/Disposal Scheme: Sludge is removed as necessary by Roberts Septic Tank Service, which has an agreement with the City of Hickory to dispose of sludge in the City's sewer collection system. 4. Treatment Plant Classification (attached completed rating sheet): Class II 5. SIC Code(s): 4952 Wastewater Code(s): 05 Main Treatment Unit Code: 06107 6. Important SOC/JOC or Compliance Schedule Dates: N/A t Page Three PART III - EVALUATION AND.RECOMMENDATIONS The permittee requests approval to expand the present WWT facility from 0.033 MGD to 0.100 MGD, which is the maximum hydraulic flow allowed by the NPDES Permit. This facility is presently operating under BPJ limitations of 15 mg/l BOD5 and 4 mg/l ammonia: The proposed expansion should not affect this facility's ability to comply with these limitations. It is recommended that no dwelling be located less than 150 feet from the WWTP. The vegetative buffering shown on the plans should be extended to enclose both the existing and proposed WWT facilities. All blowers should be housed in an enclosed structure (as shown on the plans) and should be equipped with noise suppression devices. Pending a review and approval of the plans and specifications by P&E, it is recommended that an ATC be issued. Signature Report Preparer Date Water Quality Reg nal Supervisor Date