HomeMy WebLinkAboutWQ0045267_Application (FTSE)_20240410NC Department of Environmental Quality
State of North Carolina
APR 1 2024 Department of Environmental Quality
DWR Raleigh Regional Office Division of Water Resources
FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
Division of Water Resources FTA 10-23 & SUPPORTING DOCUMENTATION
Application Number: WQ0045267 (to be completed by DWR)
All items must be completed or the application will be returned
I. APPLICANT INFORMATION:
1. Applicant's name: Town of Clams (company, municipality, HOA, utility, etc.)
2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility
❑ Federal ❑ State/County ® Municipal ❑ Other
3. Signature authority's name: Joshua Baird, PE per 15A NCAC 02T .0106(b)
Title: Engineering Director
4. Applicant's mailing address: 111 E. Second Street
City: Clayton State: NC Zip: 27520-
5. Applicant's contact information:
Phone number: (919) 553-1554 Email Address: jbaird@townofclaytonnc.org
II. PROJECT INFORMATION:
1. Project name: Woodbriar Towns
2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project ❑ ARPA funded
If a modification, provide the existing permit number: WQ00 and issued date: ,
For modifications, also attach a detailed narrative description as described in Item G of the checklist.
If new construction, but part of a master plan, provide the existing permit number: WQ00
3. County where project is located: Johnston
4. Approximate Coordinates (Decimal Degrees): Latitude: 35.641232' Longitude:-78.471285'
5. Parcel ID (if applicable): 165807-78-0784 (or Parcel ID to closest downstream sewer)
III. CONSULTANT INFORMATION:
1. Professional Engineer: Eva King, PE License Number: 39159
Firm: Adams & Hodge Engineering, PC
Mailing address: 314 East Main Street
City: Clayton State: NC Zip: 27520-
Phone number: (919) 238-1205 Email Address: eva(a)adamsandhod eg com
IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION:
1. Facility Name: Little Creek Permit Number: NC-0025453 Also listed as Sam's Branch WRF
Owner Name: Town of Clanton
V. RECEIVING DOWNSTREAM SEWER INFORMATION:
1. Permit Number(s): WQUNK
2. Downstream (Receiving) Sewer Information: 10 inch ® Gravity ❑ Force Main
3. System Wide Collection System Permit Number(s) (if applicable): WQCS00110
Owner Name(s): Town of Cla. on
FORM: FTA 10-23 Page] of 5
VI. GENERAL REQUIREMENTS
L If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached?
❑ Yes ❑ No ® N/A
2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached?
❑ Yes ❑ No ® N/A
3. If the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational Agreement (FORM: HOA) and
supplementary documentation as required by 15A NCAC 02T.0115(c) been attached?
❑ Yes ❑ No ® N/A
4. Origin of wastewater: (check all that apply):
® Residential (Individually Owned) ❑ Retail (stores, centers, malls) ❑ Car Wash
® Residential (Leased) ❑ Retail with food preparation/service ❑ Hotel and/or Motels
❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool/Clubhouse
❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash
❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment)
5. Nature of wastewater: 100 % Domestic % Commercial % Industrial (See 15A NCAC 02T .0103(20))
If Industrial, is there a Pretreatment Program in effect? ❑ Yes ❑ No
6. Hasa flow reduction been approved under 15A NCAC 02T .0114(fl? ®Yes ❑ No
➢ If yes, provide a copy of flow reduction approval letter with this application
7. Summarize wastewater generated by project:
Establishment Type (see 02T.0114(f))
Daily Design Flow a,b
No. of Units
Flow
Townhomes
250 gal/day
41
10,250 GPD
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
Total
10,250 GPD
a See 15A NCAC 02T .0114(b), L), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e. proposed unknown
non-residential development uses; public access facilities located near high public use areas; and residential property
located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4).
b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be
determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data.
8. Wastewater generated by project: 10,250 GPD (per 15A NCAC 02T .0114 and G.S. 143-215.1)
➢ Do not include future flows or previously permitted allocations
If permitted flow is zero, please indicate why:
❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line.
Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow.
❑ Flow has already been allocated in Permit Number: Issuance Date:
❑ Rehabilitation or replacement of existing sewers with no new flow expected
❑ Other (Explain):
FORM: FTA 10-23 Page 2 of 5
VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravies Sewers):
1. Summarize gravity sewer to be permitted:
Size (inches) Length (feet) Material
8 967 PVC
➢ Section 11 & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria
➢ Section III contains information related to minimum slopes for gravity sewer($)
➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC
VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (pump Stations/Force Mains):
PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED 1N THIS PROJECT
1. Pump station number or name:
2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: -
3. Total number of pumps at the pump station:
3. Design flow of the pump station: millions gallons per day (firm capacity)
➢ This should reflect the total GPM for the pump station with the largest pump out of service.
4. Operational point(s) per pump(s): gallons per minute (GPM) at feet total dynamic head (TDH)
5. Summarize the force main to be permitted (for this Pump Station):
Size (inches) Length (feet) Material
If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per
MDCPSFM Section 2.01 C. Lb. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify)
6. Power reliability in accordance with 15A NCAC 02T _0305(h)(ll:
❑ Standby power source or ❑ Standby pump
➢ Must have automatic activation and telemetry - 15A NCAC 02T_0305(h)(1)(B);
➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day
➢ Must be permanent to facility and may not be portable
Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C):
❑ Portable power source with manual activation, quick -connection receptacle and telemetry -
or
❑ Portable pumping unit with plugged emergency pump connection and telemetry:
➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station.
➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage
capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided
as part of this permit application in the case of a multiple station power outage.
FORM: FTA 10-23 Page 3 of 5
IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)):
1. Does the project comply with all separations?alternatives found in € SA NCAC 02T .0305(f) & (g}? ® Yes ❑ No
15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems:
Setback Parameter*
Separation Required
Storm sewers and other utilities not listed below (vertical)
18 inches
'Water mains (vertical - water over sewer preferred, including in benched trenches)
18 inches
'Water mains (horizontal)
10 feet
Reclaimed water lines (vertical - reclaimed over sewer)
18 inches
Reclaimed water lines (horizontal - reclaimed over sewer)
2 feet
**Any private or public water supply source, including any wells, WS-I waters of Class I or
Class 11 impounded reservoirs used as a source of drinking water, and associated wetlands.
100 feet
**Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal
high water (or tide elevation) and wetlands associated with these waters (see item IX.2)
50 feet
**Any other stream, lake, impoundment, or ground water lowering and surface drainage
ditches, as well as wetlands associated with these waters or classified as WL.
10 feet
Any building foundation (horizontal)
5 feet
Any basement (horizontal)
10 feet
Top slope of embankment or cuts of 2 feet or more vertical height
10 feet
Drainage systems and interceptor drains
5 feet
Any swimming pools
10 feet
Final earth grade (vertical)
36 inches
➢ If noncompliance with 02T.0305(f) or (,g), see Section X.1 of this application
* 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. Please check "yes"
above if these alternatives are used and provide narrative information to explain.
**Stream classifications can be identified using the Division's NC Surface Water Classifications web a e
2. Does this project comply with the minimum separation requirements for water mains? ®Yes [:]No ❑ N;'A
➢ If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document,
signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule.
3. Does the project comply with separation requirements for wetlands? ® Yes ❑ No ❑ NIA
➢ Please provide supplementary information identifying the areas of non-conformance.
➢ Seethe Division's draft separation requirements for situations where separation cannot be met.
➢ No variance is required if the alternative design criteria specified is utilized in design and construction.
4. Is the project located in a river basin subject to any State buffer rules? ® Yes Basin name: Neuse ❑ No
If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No
➢ This includes Trout Buffered Streams per 15A NCAC 2B.0202
5. Does the project require coverage?authorization under a 404 Nationwide! individual permits ❑ Yes ® No
or 401 Water Quality Certifications?
➢ Please provide the permit number'permitting status in the cover letter if coverageiauthorization is required.
6. Does project comply with I5A 'CAC.42T,Q105(c)(§) (additional permits,`certifications)? ® Yes ❑ No
Per 15A NCAC 02T,0; 056cW, directly related environmental permits or certification applications must be being prepared,
have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion
and sedimentation control plans, stormwater management plans, etc.).
7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No
Per 15A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters,
siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer.
Siphons and sewers suspended through interference/conflict boxes require a variance approval.
➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location).
High priority lines shall be inspected by the permittee or its representative at least once every six -months and
inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit.
FORM: FTA 10-23 Page 4 of 5
X. CERTIFICATIONS:
1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations
and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable?
❑ Yes ❑ No
If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application
(VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued
concurrently with the approval of the permit, and projects requiring a variance approval may be subject to longer
review times. For projects requiring two or more variances or where the variance is determined by the Division to be a
significant portion of the proiect, the full technical review is required.
2. Professional Engineer's Certification:
I Eva King, PE , attest that this application for
(Professional Engineer's name from Application Item III.1.)
Woodbriar Towns
(Project Name from Application Item IL 1)
has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans,
specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further
attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations,
Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting
of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this
submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and
have judged it to be consistent with the proposed design.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application
information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject
the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701)
North Carolina Professional Engineer's seal, signature, and date:
3. Applicant's Certification per 15A NCAC 02T .0106(b):
Joshua Baird, PE
I, ,attest that this application for
r _
i
i J 3A C
a �y
, "t ieA1 K1N 02/21/2024
Woodbriar Towns
(Signature Authority Name from Application Item I.3.) (Project Name from Application Item II.1)
attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge.
I understand that if all required parts of this application are not completed and that if all required supporting documentation
and attachments are not included, this application package is subject to being returned as incomplete. I understand that any
discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement
action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division
of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application
package are not completed and that if all required supporting information and attachments are not included, this application
package will be returned to me as incomplete.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation.
3/1 /2024
Signature: Date:
FORM: FTA 10-23 Page 5 of 5
1A HI ADAMS &. HODGE
ENGINEERING, PC
April 8, 2024
Ted Cashion
NC DWQ
3800 Barrett Dr.
Raleigh, NC 27609
Subject: Public Sewer Construction Plans
Woodbriar Towns
Town of Clayton
Dear Mr. Cashion,
Please find attached a $600.00 check for the application fee and a copy of the following:
1. Flow Tracking/Acceptance for Sewer Extension (Form FTSE 10-23)
2. Fast Track Application (Form FTA 10-23)
3. USGS Map
4. Vicinity Map
5. Flow Reduction Letter
Project Narrative:
This application is for an extension of the gravity sewer system of the Town of Clayton to serve
Woodbriar Towns. This extension includes 9671f of new 8" gravity sewer and will connect to an existing
Town of Clayton gravity sewer system with an unknown permit number. The sewer system will serve 41
single family townhomes in this subdivision. The attached flow reduction letter specifies 250 gallons/day
for each residence.
If you have any questions or comments, please give me a call at 919-238-1205 or email
eva@adamsandhodge.com
Sincerely,
Eva King, PE
ADAMS & HODGE ENGINEERING, PC • 314 E Main Street Clayton, NC 27520 • Office: 919-243-1332 • Firm # C-4187
A,(-,�
opt�'fr,
State of North Carolina
4pl? Oti,?)Pepartment of Environmental Quality
`' Division of Water Resources
l�DWR 4
,s ��1
Division of Water Resources�t't'�,; Flow Tracking for Sewer Extension Applications
dr(si ul (FTSE 10-23)
Entity Requesting Allocation: Town of Clayton .
Project Name for which flow is being requested: Woodbriar Towns
Afore than one FTSE orgy he required for a single project if lire owner of the WWTP is not responsible for all pump
stations along lire route of the proposed wastewater flow.
1. Complete this section only if you are the owner of the wastewater treatment plant.
a. WWTP Facility Name: Little Creek Also listed as Sam's Branch WRF
b. WWTP Facility Permit 4: NC-0025453
All f lows are in MGD
c. WWTP facility's permitted flow LCWRF 2.5 - JoCo 1.4 +
Raleigh 1.75 = 5.65 MGD
d. Estimated obligated flow not yet tributary to the WWTP .913
e, WWTP facility's actual avg. flow 3.488
f. Total flow for this specific request .0103
g. Total actual and obligated flows to the facility 4.411
h. Percent of permitted flow used 7 8. 1°}o
II. Complete this section for each pump station you are responsible for along the route of this proposed
wastewater flow.
List pump stations located between the project connection point and the WWTP:
(A) (B) (C) (D)=(B+C) (E)=(A-D)
Design Obligated,
Pump Pump Average Approx. Not Yet Total Current
Station Station Firm Daily Flow** Current Tributary Flow Plus
(Name or Permit Capacity, * (Firm ' pf), Avt,, Daily Daily Flow, Obligated Available
Number) No. MGD MGD Flock., MGD MGD Flow Capacity* *{
* The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be
achieved with the largest pump taken out of service.
** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not
less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria.
** k A Planning Assessment Addendum shall be attached for each pump station located between the
project connection point and the WWTP where the Available Capacity is < 0.
Downstream Facility Name (Sewer): eww
Page 1 of 7
FTSE 10-23
Confirmed witthh�J. Baird
Town of Clayton Collection System
Downstream Permit Number: err WQCS00110
II1. Certification Statement:
I Joshua Baird, PE certify to the best of my knowledge that the addition of
the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving
wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity
related sanitary sewer overflows or overburden any downstream pump station en route to the receiving
treatment plant under normal circumstances, given the implementation of the planned improvements
identified in the planning assessment where applicable. This analysis has been performed in accordance
with local established policies and procedures using the best available data. This certification applies to
those items listed above in Sections I and I1 plus all attached planning assessment addendums for which I
am the responsible party. Signature of this form certifies that the receiving collection system or treatment
works has adequate capacity to transport and treat the proposed new wastewater.
0
Official Signature
Engineering Director
Title of Signing Official
3/1/2024
Date
Page 2 of 7
FTSE 10-23
The National Map Advanced Viewer
9/2/2022, 11:12:50 AM
1:9,028
0 0.05 0.1 0.2 mi
0 0.1 0.2 0.4 km
USGS The National Map: National Boundaries Dataset, 3DEP Elevation
Program, Geographic Names Information System, National Hydrography
Dataset, National Land Cover Database, National Structures Dataset, and
National Transportation Dataset; USGS Global Ecosystems; U.S. Census
USGS
2021 USGS
State of North Carolina
Department of Environment
and Natural Resources
Division of Water Quality
Michael F. Easley, Governor
William G. Ross Jr., Secretary
Kerr T. Stevens, Director
July 2, 2001
Mr. Steve Biggs, Town Manager
Town of Clayton
Post Office Box 879
Clayton, North Carolina 27520
JUL u till,!
�s
NCDENR
NORTH CAROLINA DEPARTMENT OF
ENVIRONMENT AND NATURAL RESOURCES
Subject: Town of Clayton
Flow Reduction Approval
Johnston County
Dear Mr. Biggs:
On January 3, 2001, the Division of Water Quality received your flow reduction request for new
single-family dwellings in the Town of Clayton. The letter requests approval of a residential flow value of 250
GPD/residence for any future dwellings that may become tributary to the subject wastewater collection system.
The Division also received additional information on April 3, 2001
The information provided flow records between January 1998 and November 2000 for the WWTP.
The evaluation also included the daily wastewater flows for a 33 day period from February 19 through March
23, 2001 for a select 97 homes in accordance with 15A NCAC 2H .0219(l)(3).
Based upon the information submitted, the Division hereby approves the use of 250 GPD per single-
family residence in all applicable non -discharge permit applications for future sewer line extensions for the
Town of Clayton. This consideration applies to any applicable future projects submitted to the Division as well
as any projects which are currently under review. Regardless of the ad'usted design daily wastewater flow rate
at no time shall the wastewater flows exceed the effluent limits defined in the Town's NPDES permit for the
treatment facility or exceed the capacity of the sewers downstream of any new sewer extension.
If you have any questions or comments regarding this matter, please contact Mr. Kim H. Colson at
(919)733-5083 ext. 540.
Si ely,
Kerr T. Stevens
cc: Raleigh Regional Office
1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone 919-733-5083 Fax 919-715-6048
An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper
[External] RE: Woodbriar Towns -Additional Information Request
Eva King <Eva@adamsandhodge.com>
Wed 4/10/2024 10:27 AM
To:Pasha, Tanvir<tanvir.pasha@deq.nc.gov>;Joshua Baird <jbaird@townofclaytonnc.org>
Cc:Amanda Grimm <amanda@adamsandhodge.com>
5 attachments (4 MB)
1-Woodbriar Towns Narrative.pdf, 2-FTA 10-23 & FTSE Woodbriar Towns_signed.pdf; 3-Sewer Flow Reduction Letter 7-2-
2001.pdf; 4-USGS MAP-Sewer.pdf; 5-AERIAL MAP.pdf;
You don't often get email from eva@adamsandhodge.com. Learn why this is important
CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report
Message button located on your Outlook menu bar on the Home tab.
Tanvir,
Attached please find our resubmittal for Woodbriar Towns.
Please let me know if you need us to send in a physical copy as well.
Thank you,
Eva King, PE
Senior Civil Engineer
JA&H ARAM & HODGE
E N 13 1 N IM IIE PINI3
314 E. Main St., Clayton, NC 27520 - (M)919-238-1205 - (0)919-243-1332 - Firm # C-4187
From: Pasha, Tanvir <tanvir.pasha@deq.nc.gov>
Sent: Thursday, April 4, 2024 11:22 AM
To: Eva King <Eva@adamsandhodge.com>; Joshua Baird <jbaird@townofclaytonnc.org>
Subject: Woodbriar Towns —Additional Information Request
Hello Joshua and Eva,
After reviewing the Fast Track Sewer System Extension Application for Woodbriar Towns, additional information
is required in order to further process the application. Please provide the following information by May 03,,
2024, and note that the requested information must be submitted within 30 days of this request, or the
applicant will be required to submit a new application and application fee in accordance with 15A NCAC 02T
.0107.
1. Is this an ARPA funded project? If so,_please include the DWI assigned ARPA project number in
your response.
2. Section 1.2 of the FTA needs to be checked.
3. Section V1.6 of the FTA needs to be checked.
4. FTA was signed by Eva King; however, the narrative was signed by Amanda Grimm. Please provide
an updated narrative or else provide PE license number of Amanda Grimm.
5. According to Section F of the Application Instructions, an 8.5-inch x 11-inch color copy of a USGS
Topographic Map and an aerial map should be included with the application. The maps need to clearly
identify the project area, including the closest surface waters, general location of the gravity sewer,
pumpstations, and force mains, and the downstream connection points for the receiving sewer. Please
provide the required maps according to the application requirements.
15A NCAC 02T .0107 Staff Review and Permit Preparation states:
• "(2) (e) If an application is accepted and later found to be incomplete, the applicant shall be
advised how the application or accompanying supporting information may be modified to make it
complete. The staff shall advise the applicant:
(2) if all required information is not submitted within 30 days, the project will be returned as
incomplete. Any resubmittal of a returned application shall be accompanied with a new application
fee."
Please contact me with any questions that you may have regarding this request.
*Please note that the fee for fast track sewer extension permits has increased to $600 as of October 3, 2023
[as stipulated in the 2023 House Appropriations Act, House Bill 259, Water Quality and Stormwater Fees,
Section 12.14(a)].
Sincerely,
A B M "Tanvir" Pasha (he/him)
Environmental Engineer
Division of Water Resources — Raleigh Regional Office
North Carolina Department of Environmental Quality
3800 Barrett Drive, Raleigh, NC 27609
Office: 919-791-4250; Cell: 984-202-3390
tanvirpasha@deq.nc.gov
E14,10)
NORTH CAROLINA
Department of Environmental Quality
Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties by an
authorized state official.