HomeMy WebLinkAbout20240175 Ver 1_USACE Permit_20240412DEPARTMENT OF THE ARMY U.S. ARMY CORPS OF ENGINEERS, WILMINGTON DISTRICT ASHEVILLE REGULATORY FIELD OFFICE 151 PATTON AVENUE SUITE 208 ASHEVILLE NC 28801 April 12, 2024 Regulatory Division 2024-00200 Deron Geouque Watauga County 814 West King Street Boone, NC 28607 Via Email: deron.geouque@watgov.org Dear Mr. Geouque: This letter is in response to the Pre -Construction Notification (PCN) you submitted to the Wilmington District, Asheville Regulatory Field Office on January 24, 2024, for a Department of the Army Nationwide permit (NWP) verification. This project has been assigned the file number 2024-00200 and is known as the Mouth of Hardin Creek Restoration. This file number should be referenced in all correspondence concerning this project. A review of the information provided indicates that the proposed work would include stream restoration to approximately 2,520 linear feet of Hardin Creek and its unnamed tributaries along with 1.535 acre of wetlands. This activity, as described, complies with all terms and conditions of the. The project area is illustrated on the enclosed site plans/maps and located at Latitude 36.21219 and Longitude -81.64937, near 300 Go Pioneers Drive, in Boone, Watauga County, North Carolina. We have determined that the proposed work is authorized by Nationwide #27 pursuant to authorities under Section 404 of the Clean Water Act (33 U.S.0 § 1344). The proposed work must be accomplished in strict accordance with the general permit conditions, any regional conditions, the application materials, and the enclosed plans. A special condition of this authorization prohibits in -stream work from October 15 to April 15 to avoid/minimize impacts to trout spawning as recommended in the attached letter from the North Carolina Wildlife Resources Commission. To avoid/minimize impacts to federally endangered/threatened bat species, tree clearing is prohibited from April 1- October 15 which is also a special condition of this permit authorization. If the extent of the project area and/or nature of the authorized impacts to waters are modified, a revised PCN must be submitted to this office for written approval before work is initiated. Any violation of permit conditions or deviation from your submitted plans may subject the permittee to enforcement action. This verification is valid until March 14, 2026, unless prior to this date the subject NWP(s) is suspended, revoked, or is modified such that the activity no longer complies with the terms and conditions of this NWP. If you commence or are under contract to commence this activity before the date that the relevant NWP is modified or revoked, you will have 12 months from the date of the modification or revocation of the NWP to complete the activity under the present terms and conditions of this NWP. This NWP verification does not preclude the necessity to obtain any other Federal, State, or local permits, licenses, and/or certifications, which may be required. If you have any questions related to this verification or have issues accessing documents referenced in this letter, please contact Amanda Fuernmeler, Project Manager of the Asheville Regulatory Field Office at (828)271-7980 x4225, by mail at the above address, or by email at amanda.jones@usace.army.mil. Please take a moment to complete our customer satisfaction survey located at https://regulatory.ops.usace.army.miI/customer-service-survey/. Sincerely, 0 �- Amanda Jones Fuernmeler Project Manager Enclosures Cc: Jennings Environmental, PLLC, Attn: David Brown (via email) 0 North Carolina Wildlife Resources Commission 9 Cameron Ingram, Executive Director February 25, 2024 Ms. Amanda Fuemmeler U.S. Army Corps of Engineers, Regulatory Branch 151 Patton Avenue, Room 208 Asheville, North Carolina 28801-5006 SUBJECT: Mouth of Hardin Creek Restoration UTs South Fork New River and Wetlands, Watauga County Dear Ms. Fuemmeler: Biologists with the North Carolina Wildlife Resources Commission (NCWRC) reviewed an application to restore 2,520 ft of three unnamed tributaries (UTs) to the South Fork New River and impact 1.54 acre of wetland in Watauga County. Our comments on this application are offered for your consideration under provisions of the Clean Water Act of 1977 (33 U.S.C. 466 et. seq.) and Fish and Wildlife Coordination Act (48 Stat. 401, as amended; 16 U.S.C. 661- 667d). There are Rainbow Trout and Brown Trout in the vicinity of the project, and in -stream activities should be avoided between October 15 and April 15 in order to minimize impacts to trout reproduction. In addition, the South Fork New River is recognized by the NC Natural Heritage Program as the South Fork New River Aquatic Habitat, rated Exceptional for the richness of rare species it contains. Rare and listed species found in the river in the vicinity of the project include Seep Mudalia [Leptoxis dilatata, NC Special Concem (SC)], Kanawha Minnow (Phenacobius terelutus, NC SQ, Eastern Hellbender (Cryptobranchus alleganiensis, US Federal Species of Concern, NC SQ, Kanawha Darter [Etheostoma kanawhae, NC Significantly Rare (SR)], Tongue-tied Minnow (Exoglossum laurae, NC SR), Kanawha Rosyface Shiner (Notropis sp., NC SR), and Appalachia Darter (Percina gymnocephala, NC SR). These rare species are especially sensitive to sediment, and excellent erosion and sediment control is essential to minimize impacts to these species. The application proposes to stabilize unstable reaches of stream by building a new channel with constructed riffles, log vanes, boulder and log j -hooks, and toewood. Berms will be removed and floodplain benches constructed. A 75-ft wide riparian buffer will be planted. Work will involve considerable wetland impacts, although wetlands within floodplain benches will be restored and Mailing Address: Habitat Conservation - 1721 Mail Service Center - Raleigh, NC 27699-1721 Telephone: (919) 707-0220 - Fax: (919) 707-0028 Mouth of Hardin Creek Restoration Page 2 February 25, 2024 UTs South Fork New R & Wetlands, Watauga Co 0.41 acre of new wetland created. Mud mats will be used to cross wetlands and timber bridges used to cross streams. The channel will mostly be constructed off-line. We offer the following recommendations to minimize impacts to the aquatic community: 1. In -channel work should be accomplished as quickly as possible and vigilance used in sediment and erosion control during site preparation, construction, and clean up. Disturbed areas should be seeded, mulched and/or matted as soon as possible, preferably at the end of each work day. 2. Where work is to be done in live flows, flows should be pumped around work areas due to the ecological importance of the South Fork River just downstream. 3. Any erosion control matting used should be free of nylon or plastic mesh, as this type of mesh netting frequently entangles wildlife and is slow to degrade, resulting in a hazard that may last for years. 4. In -stream activities should be done outside the October 15 to April 15 trout moratorium to minimize impacts to Brown Trout reproduction. 5. A large area of wetland will be impacted, but the plan does not specify any wetland plantings. We recommend using native wetland seed mix for impacted wetland areas. Thank you for the opportunity to review and comment on this project. Please contact me at (828) 400-4223 if you have any questions about these comments. Sincerely, Andrea Leslie Mountain Region Coordinator, Habitat Conservation Program cc: David Brown, Jennings Environmental Seren Homer, NC Division of Water Resources 0_4 r-4 7t CY) �q CY) ,It 04 C) 04 cli N m CU _0 C 0 W 0 _j 0- C) Lu _j U) LU 00 N C) 04 cli 04 - CU 3 5 Q Lu U) U) 0� r Ld 0 z 06 W Lu 0 U) 0 0 Know what's below. Call before you dig HARDIN CREEK RESTORATION HARDIN CREEK - WATAUGA COUNTY TOWN OF BOONE, NORTH CAROLINA LAT: 36.211312, LONG: -81.648139 PROJECT DIRECTORY PROJECT SPONSOR NEW RIVER CONSERVANCY KATIE KROGMEIER RESTORATION DIRECTOR KATI E@N EWRIVERCONSERVANCY.ORG DESIGN TEAM ENGINEER JENNINGS ENVIRONMENTAL PLLIC GREG JENNINGS, PHD, PE PRESIDENT GREG@JENNINGSENV.COM SURVEYOR PILOTSE, P.C. CORY GEORGE, PE, PLS PRESIDENT CORY@PlLOTSE.COM CONSTRUCTION CONTRACTOR NORTH STATE ENVIRONMENTAL BRANDON SPAUGH CHIEF OPERATING OFFICER B.SPAUGH@NSENV.COM PROPERTY OWNER(S) PIN OWNER 2910-8834-56000 WATAUGA COUNTY 2910-6688-24000 STATE OF NORTH CAROLINA SHEETINDEX COVER SHEET 1.1 GENERAL PROJECT NOTES AND SPECIFICATIONS 1.2 NC CONSTRUCTION GENERAL PERMIT (NCG01) 1.3-1.4 LEGEND & TYPICAL SECTIONS 1.5 STREAM RESTORATION - PLAN & PROFILES 2.1-2.7 SECTIONS 3.1-3.2 DETAILS 4.1-4.6 EROSION & SEDIMENTATION CONTROL (ESC) 5.1-5.5 RE -VEGETATION 6.1-6.4 NX IYOWA DS KNOB,RD 13 ckeyE 194 fly rn 'rA �Atauga 11-res ,ounty Zourthouse G 321 TRACY C111 A�A A ' _,�Kaate% i _-Ij 11 Boone Cem [Ed: (rrr-, (D --\, Mount 11 D US� Van noy C 44 ' 0 9 221 421 BUB T- '0� LLI FLo\N Ed t C MI. 1 t ( mis en-,e IT. 14 - CHARLIE HOLLAR RD S FOF ,K NEW 21 C, 4&v �Al E-4 CIR -ROONE PROJECT COORDINATES ,L4S4 Edmisten Cem 00 221 321 __� ffik SHADOWLI"' cl� ) \L_.r1,ht_4_v_C_0oK I Bromn & 1655) IQ, v Z H C3 4- Boone Inc Airport 0 cl�, P ook-CerT CA 0 /N 75472((- EA NOT FOR CONSTRUCTION PERMIT DRAWING January 22, 2024 LL. CL CL 0 < z co Z 0 co 0 g: LLJ LLj LU = 0 0 Q LU 0 > Lu z Z Z _j 0 D 0 0 z �_ < (-) 0 0� < C) (D 0 (D m z I— C/) D < 0� — �: LU LLJ Lu < 0 Z < Cl) �: - z 0 LLJ LLJ z Lu c) LLJ 0 0 0� C) LU 0 LLJ (.) 0 z 13� 00 a_ LL C) LL 0 I— 0 Z z < z 0 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 DATE: 1/22/2024 SCALE (34"X22"): 1 " = 1500' SCALE (1 7X1 1 "): 1 " = 3000' 0 1500 3000 SCALE IN FEET SHEET NUMBER 1.1 GENERAL PROJECT NOTES AND SPECIFICATIONS 0_4 r-4 Lo 7t cy) �q cy) ,It 04 C) 04 cli N Ll m m m _0 w 0 0 uj 0 U) LLI 00 Lp 0) 'IT N C) 04 cli 04 - cu 3 5 Q Lu U) U) 0� r 0 Ld 0 z 06 w Lu 0 U) 1. DEFINITIONS: 1. 1. CONSTRUCTION DOCUMENTS- THE CONTRACT AND APPLICABLE DRAWINGS, DETAILS, SPECIFICATIONS, PERMIT(S), AND/OR ANY OTHER DOCUMENTS (MEETING MINUTES, PUNCH LISTS, BID TABS, ETC.) FOR COMPLETE INFORMATION ABOUT THE REQUIRED WORK. ANY ONE OF THESE PARTS OF THE MAY NOT CONTAIN ALL OF THE INFORMATION REQUIRED TO COMPLETE THE PROJECT WORK. 1.2. ENGINEER- JENNINGS ENVIRONMENTAL PLLC 2. THE WORK ON THIS PROJECT SHALL ADHERE TO THE FOLLOWING SPECIFICATIONS, STANDARDS AND/OR REGULATIONS- 2.1. NC DEMLR'S "EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL" (2013) 2.2. NC DEMLR'S CONSTRUCTION GENERAL PERMIT NUMBER NCGO1000 2.3. GENERAL, REGIONAL AND SPECIAL CONDITIONS OF USACE'S 404 NATIONWIDE PERMIT NUMBER 27 2.4. GENERAL AND SPECIAL CONDITIONS OF NCDWR'S 401 WATER QUALITY CERTIFICATION 4134 2.5. THE CONSTRUCTION DOCUMENTS 3. ALL EXISTING UTILITIES MAY NOT BE SHOWN. SOME LOCATIONS MAY BE APPROXIMATE. CONTRACTOR SHALL NOTIFY'NC811' (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF INC81 1'. REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. ANY UTILITIES SHOWN ON THE CONSTRUCTION DOCUMENTS ARE FOR INFORMATIONAL PURPOSES ONLY AND IN NO WAY RELIEVES THE CONTRACTOR FROM COORDINATING, VERIFYING, AND PROTECTING EXISTING UTILITIES. 4. ALL UTILITIES SHALL BE PROTECTED AND REMAIN ACTIVE UNLESS OTHERWISE NOTED. CONTRACTOR IS RESPONSIBLE FOR COORDINATING CONSTRUCTION ACTIVITIES WITH THE APPROPRIATE UTILITY COMPANIES FOR ANY REQUIRED RELOCATIONS (I.E. POWER POLES, METERS, FITTINGS, ETC.). 5. THE CONTRACTOR IS RESPONSIBLE FOR THE PROJECT AREA UNTIL COMPLETION AND FINAL ACCEPTANCE BY THE ENGINEER AND PROJECT OWNER. THE CONTRACTOR SHALL CONFINE ALL ACTIVITIES, INCLUDING EQUIPMENT STORAGE, TO THE LIMITS OF DISTURBANCE, STAGING AREAS, AND DESIGNATED CONSTRUCTION ACCESS POINTS. 6. THE MANNER IN WHICH THE CONTRACTOR DEALS WITH PEOPLE AND THEIR PROPERTIES WHILE PERFORMING THIS WORK IS EXTREMELY IMPORTANT. THEREFORE, THE CONTRACTOR AND THE CONTRACTOR'S REPRESENTATIVES SHALL MANIFEST A SPIRIT OF FRIENDLINESS AND COOPERATION WHEN DEALING WITH PROPERTY OWNERS AND THE GENERAL PUBLIC WHILE PERFORMING WORK ON THE SITE. 7. EXTREME CARE AND DILIGENCE SHALL BE EXERCISED BY THE CONTRACTOR TO ASSURE THE SAFETY OF PERSONS, ANIMALS, AND PROPERTY. IF AT ANY TIME THE OWNER OR ENGINEER DETERMINES THAT THE CONTRACTOR'S METHODS OR EQUIPMENT ARE INADEQUATE FOR SECURING THE SAFETY OF THE CONTRACTOR'S EMPLOYEES OR THE PUBLIC, THE DESIGNATED REPRESENTATIVE MAY DIRECT THE CONTRACTOR TO TAKE SPECIFIC ACTIONS TO ENSURE SAFETY. THE CONTRACTOR SHALL IMPROVE METHODS AS DEEMED APPROPRIATE BY THE DESIGNATED REPRESENTATIVE WITHOUT ADDITIONAL COST TO THE PROJECT OWNER, SO AS TO ASSURE COMPLIANCE WITH SAFETY CONCERNS. FAILURE OF THE DESIGNATED REPRESENTATIVE TO MAKE THIS DEMAND SHALL NOT RELIEVE THE CONTRACTOR OF ANY OBLIGATION TO ENSURE THE SAFE CONDUCT OF ITS WORK. 8. THE CONTRACTOR SHALL MAINTAIN ALL LIGHTS, GUARDS, SIGNS, TEMPORARY PASSAGES, OR OTHER PRECAUTIONS NECESSARY FOR THE SAFETY OF ALL PERSONS. THE CONTRACTOR SHALL ABIDE BY ALL SAFETY RULES AND CONSTRUCTION CONDITIONS REQUIRED BY GOVERNMENTAL AUTHORITIES AND OTHER ENTITIES, INCLUDING RAILROADS, SO THE PUBLIC IS SAFEGUARDED FROM ACCIDENTS AND DELAYS. GUARDS AND FLAGS REQUIRED BY GOVERNMENTAL OR RAILROAD AUTHORITIES SHALL BE PROVIDED AT THE CONTRACTOR'S EXPENSE, UNLESS DIRECTED OTHERWISE BY THE DESIGNATED REPRESENTATIVE. CONTRACTOR SHALL AT NO TIME COMPROMISE EITHER SAFETY OR ENVIRONMENTAL REQUIREMENTS. 9. THE CONTRACTOR SHALL ONLY USE ACCESS PATHS AND STAGING AREAS SHOWN ON THE DRAWINGS. ANY ALTERNATE ACCESS PLANNED BY THE CONTRACTOR SHALL BE APPROVED BY THE ENGINEER AND PROJECT OWNER PRIOR TO USE. 10. NO NON -PERMITTED FILL IN WETLANDS MAY OCCUR. ALL EXCESS SOILS FROM STABILIZATION AND GRADING WORK SHALL BE PLACED IN DESIGNATED AREAS ON THE SITE. 11. SITE SHOULD BE "STORM READY" AT THE END OF EACH WORK DAY AND WORK WEEK. TOPOGRAPHIC NOTES AND SPECIFICATIONS 12. HORIZONTAL DATUM IS NAD83(201 1) & VERTICAL DATUM IS NAVD88. ALL COORDINATES ARE BASED ON NAD83(201 1) AND ALL ELEVATIONS ARE BASED ON NAVD88. 13. THE DESIGN ELEVATIONS AND GRADES SHOWN IN THE DRAWINGS ARE BASED ON THE EXISTING GROUND SURFACE FROM THE SEPTEMBER AND NOVEMBER 2023 SURVEY, ADDITIONAL GROUND ELEVATIONS SHOWN ARE SUPPLEMENTED WITH NORTH CAROLINA SPATIAL DATA DOWNLOAD QL1/QL2 LIDAR. ALL COMPUTATIONS OF CUT AND FILL ARE BASED ON THE EXISTING GROUND SURFACE. DISCREPANCIES BETWEEN THE EXISTING GROUND SURFACE AND FIELD CONDITIONS AT THE TIME OF CONSTRUCTION CAN RESULT IN VARIATIONS OF TOTAL EXCAVATED QUANTITIES. THESE VARIATIONS SHALL BE CONSIDERED INCIDENTAL TO CONSTRUCTION. STREAM RESTORATION NOTES AND SPECIFICATIONS 14. FIELD CONDITIONS MAY REQUIRE ADAPTATION OF THE DESIGN AND/OR DETAILS PROVIDED IN THE DRAWINGS. MINOR VARIATION(S) OR ADAPTATION(S) OF THE PROPOSED WORK SHOWN IN THE DRAWINGS AND DETAILS ARE CONSIDERED INCIDENTAL TO THE WORK. THE ENGINEER WILL WORK WITH THE CONTRACTOR TO ADDRESS ANY FIELD CHANGES. 15. IN -STREAM ROCK STRUCTURES MAY BE SUBSTITUTED WITH WOOD STRUCTURES WITH WRITTEN APPROVAL FROM THE ENGINEER. 16. THE CONTRACTOR SHALL MARK THE LOCATIONS OF BANK STABILIZATION STRUCTURES USING SURVEY GRADE GPS EQUIPMENT FOR REVIEW BY THE ENGINEER BEFORE BEGINNING EXCAVATION AND GRADING. 17. CONTRACTOR SHALL MINIMIZE, TO THE MAXIMUM EXTENT POSSIBLE, IMPACTS TO ADJACENT SIGNIFICANT TREES. 18. CONTRACTOR SHALL USE AN EXCAVATOR WITH A HYDRAULIC THUMB TO INSTALL BANK STABILIZATION STRUCTURES. 19. DESIGN ELEVATIONS SHALL BE CONSTRUCTED WITHIN 0.1'(VERTICAL). WIDTHS AND DEPTHS MUST FALL WITHIN RANGES SHOWN IN THE DRAWINGS AND DETAILS. 20. IF THE EXISTING GROUND IS LESS THAN 0.2' HIGHER THAN THE PROPOSED BANKFULL ELEVATION, IT IS NOT NECESSARY TO EXCAVATE TO THE PROPOSED ELEVATIONS AND GRADES IN THE CONSTRUCTION DOCUMENTS. 21. BANK STABILIZATION STRUCTURES SHALL BE INSTALLED AS SHOWN IN THE DRAWINGS AND DETAILS. ALL STRUCTURES SHALL BE FINISHED TO A SMOOTH SURFACE IN ACCORDANCE WITH THE LINES, GRADES AND ELEVATIONS SHOWN IN THE DRAWINGS AND DETAILS. THE FINISHED STRUCTURE SLOPES AND GRADES SHALL BE WITHIN 0.1'OF DESIGN ELEVATIONS. 22. AFTER THE STRUCTURE IS COMPLETE AND NORMAL FLOW IS RESTORED TO THE CHANNEL, SOME ADJUSTMENT TO THE STRUCTURE OR ADDITIONAL STABILIZATION MEASURE MAY BE NECESSARY TO ACHIEVE THE DESIRED FUNCTION. 23. THE GRADED RIVER BANKS SHALL BE STABILIZED AS SOON AS POSSIBLE BY TEMPORARY AND PERMANENT SEEDING, ADDING STRAW MULCH TO BARE SOIL AND INSTALLING EROSION CONTROL MATTING AS SHOWN IN THE DRAWINGS AND DETAILS. PRIOR TO INSTALLING THE EROSION CONTROL MATTING, PREPARE THE SOIL SURFACE BY LOOSENING 3 - 6" OF SOIL OR APPLYING 3 - 6" OF TOPSOIL TO THE DESIGN ELEVATIONS AND APPLY TEMPORARY AND PERMANENT SEED AND THEN STRAW MULCH. SEED SHALL BE BROADCAST EVENLY OVER THE AREA USING A BROADCAST SPREADER PRIOR TO COVERING WITH THE EROSION CONTROL MATTING. THE MATTING SHALL BE ROLLED OUT IN THE DIRECTION OF ANTICIPATED RUNOFF. INSTALL MATTING IN ACCORDANCE WITH THE DETAIL INCLUDED IN THE DRAWINGS. MATTING USED FOR STREAMBANK STABILIZATION MUST BE CERTIFIED WEED -FREE STRAW OR OTHER NATURAL WEED -FREE / NON -PROPAGATING VEGETATIVE MATERIALS. REWORKING OF AREAS THAT DO NOT ESTABLISH VEGETATION OR BECOME UNSTABLE SHALL BE NECESSARY IN THE MATTING SEPARATES FROM THE SOIL. 24. TOPSOIL SHALL BE REMOVED FROM EXCAVATION AND FILL AREAS PRIOR TO EXCAVATION AND GRADING AND RE -APPLIED TO AREAS AFTER ROUGH GRADING IS COMPLETE. 2 - 4" OF TOPSOIL SHALL BE PLACED ON DISTURBED AREAS TO THE ELEVATIONS AND GRADES INCLUDED IN THE DRAWINGS. 25. HYDRIC SOILS FROM THE DISTURBED WETLAND AREA(S) WILL BE STOCKPILED SEPARATE FROM OTHER STOCKPILED SOILS AT THE SITE. THESE SOILS WILL BE PLACED WITHIN RESTORED WETLAND AREAS AND/OR PLACED WITHIN CONSTRUCTED WETLAND AREAS. RESTORATION DESIGN WILL ENHANCE EXISTING WETLAND HYDROLOGY AND DISTURBED WETLAND AREAS WILL BE SEEDED WITH A NATIVE WETLAND MIX AND WHERE AVAILABLE THE SEED MIX WILL INCLUDE HERBACEOUS WETLAND POLLINATOR SPECIES. EROSION AND SEDIMENTATION CONTROL NOTES AND SPECIFICATIONS 26. ALL CONSTRUCTION ACTIVITIES SHALL ADHERE TO THE CONDITIONS AND REQUIREMENTS OF NCDEMLR'S NG01 CONSTRUCTION GENERAL PERMIT. 27. ALL TREES, UTILITIES AND OTHER SITE FEATURES SHALL BE PROTECTED UNLESS MARKED FOR REMOVAL OR RELOCATION. 28. ALL WETLANDS AND STREAMS LOCATED WITHIN 50 FEET OF THE CONSTRUCTION AREA ON THE PROJECT SITE SHALL BE CLEARLY MARKED (EXAMPLE- ORANGE FABRIC FENCING) PRIOR TO ANY LAND DISTURBING ACTIVITIES AND MUST BE MAINTAINED ON THE PROPERTY UNTIL THE PROJECT PHASE IS COMPLETED [15A NCAC 02H.0506 (13)(2)]. 29. THE CONTRACTOR SHALL USED A STANDARD CONSTRUCTION ENTRANCE AT ALL SITE ACCESS POINTS TO PREVENT SEDIMENT FROM BEING TRACKED ONTO PUBLIC ROADS. 30. THE CONTRACTOR SHALL USED TEMPORARY SILT FENCE ALONG THE DOWNSLOPE SIDE OF ALL STAGING AREAS AND TEMPORARY STOCK PILE AREAS. 31. THE TURBIDITY IN THE RECEIVING WATERS SHALL NOT EXCEED 50 NEPHELOMETRIC TURBIDITY UNITS (NTU) IN STREAMS NOT DESIGNATED AS TROUT WATERS AND 10 NTU IN STREAMS, LAKES, OR RESERVOIRS DESIGNATED AS TROUT WATERS, AS DESCRIBED IN 15A NCAC 02B .0200. APPROPRIATE SEDIMENT AND EROSION CONTROL PRACTICES MUST BE USED TO MEET THIS STANDARD. [15A NCAC 02B .0211 (21)]. 32. EQUIPMENT SHALL BE WELL -MAINTAINED, CLEANED PRIOR TO MOBILIZATION, AND CHECKED DAILY FOR LEAKS OF PETROLEUM PRODUCTS. FUELING, LUBRICATION AND GENERAL EQUIPMENT MAINTENANCE SHOULD NOT TAKE PLACE WITHIN 50 FEET OF A WATERBODY OR WETLANDS TO PREVENT CONTAMINATION BY FUEL AND OILS. [1 5A NCAC 02H .0506 (B)(3) AND 15A NCAC 02B.0211(12)]. 33. CONSTRUCTION SHALL BE TIMED TO OCCUR DURING TIMES OF LOW FLOW 34. THE DESIGNER OR HIS DESIGNEE SHALL SUPERVISE THE INSTALLATION OF IN -STREAM STRUCTURES. [1 5A NCAC 02H .0506(B)(1) AND (2)]. 35. A TEMPORARY DIVERSION AND/OR PUMP AROUND SYSTEM SHALL BE USED TO DURING ALL STREAM RESTORATION AND STABILIZATION WORK AS SHOWN IN THE DETAILS. TEMPORARY PUMP AROUND SYSTEM SHALL BE USED AT PROJECT SITES WHERE THE WATERSHED SIZE IS LESS THAN 2 SQUARE MILES. 36. THE STREAM BANKS, IN -STREAM STRUCTURES, AND WORK AREA MUST BE STABILIZED AT THE END OF EACH DAY BEFORE THE TEMPORARY IN -STREAM DIVERSIONS AND/OR PUMP AROUND SYSTEM(S) ARE REMOVED AND FLOW IS RETURNED THE FULL CHANNEL. 37. EROSION CONTROL MATTING THAT INCORPORATES PLASTIC MESH AND/OR PLASTIC TWINE SHALL NOT BE USED ALONG STREAMBANKS OR WITHIN WETLANDS. DISTURBED AREAS SHOULD BE SEEDED, MULCHED, AND/OR MATTED AS SOON AS POSSIBLE, PREFERABLY AT THE END OF EACH WORKDAY. [15A NCAC 02B.0201] 38. IF BORROW OR WASTE MATERIAL IS REQUIRED OR GENERATED DURING GRADING OPERATIONS, AN APPROVED EROSION AND SEDIMENT CONTROL PERMIT MUST BE SECURED FOR THE BORROW OR WASTE MATERIAL SITE PRIOR TO INITIATION OF ANY LAND DISTURBING ACTIVITY. [15A NCAC 04B.01 10]. QUANTITIES AND MATERIALS NOTES AND SPECIFICATIONS 39. THE CONTRACTOR SHALL FURNISH ALL MATERIALS NECESSARY TO COMPLETE THE PROPOSED WORK UNLESS OTHER PROVISIONS HAVE BEEN AGREED UPON PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL DELIVER ALL MATERIALS TO THE DESIGNATED ACCESS POINTS AND STAGING AREAS. MATERIAL QUANTITIES, DIMENSIONS AND SIZES SHALL CONFORM TO THE NOTES AND SPECIFICATIONS PROVIDED IN THE CONSTRUCTION DOCUMENTS. THE ENGINEER MAY INSPECT AND APPROVE ALL MATERIALS PRIOR TO CONSTRUCTION. IF MATERIALS DO NOT MEET THE MINIMUM REQUIREMENTS SPECIFIED IN THE CONSTRUCTION DOCUMENTS, THE ENGINEER SHALL REJECT THE MATERIALS. 40. COSTS INCURRED DUE TO PROJECT DELAYS RESULTING FROM FAILURE OF THE CONTRACTOR TO MEET THE REQUIREMENTS OF THE CONSTRUCTION DOCUMENTS SHALL BE THE EXPENSE OF THE CONTRACTOR. QUANTITIES LISTED ARE ESTIMATES ONLY AND SHALL BE CONFIRMED BY THE CONTRACTOR. 41. THE EROSION CONTROL MEASURES DEPICTED ON THE DRAWINGS SHALL BE INSTALLED AS NEEDED TO KEEP ALL SEDIMENT ON SITE AND OUT OF STREAMS AND WETLANDS. ADDITIONAL EROSION CONTROL MEASURES (ABOVE THOSE SHOWN ON THE DRAWINGS) MAY BE REQUIRED IN ORDER TO KEEP ALL SEDIMENT ON SITE AND OUT OF STREAMS AND WETLANDS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE PROJECT OWNER AND ENGINEER PRIOR TO INSTALLATION OF ADDITIONAL EROSION CONTROL MEASURES. 42. ANY ADDITIONAL GRADING OTHER THAN WHAT IS SHOWN ON THE PLANS SHALL REQUIRE PRIOR APPROVAL FROM THE PROJECT OWNER AND ENGINEER. 43. THE USE OF ANY BRAND NAMES/MANUFACTURERS OR MODELS IS INTENDED SOLELY TO DENOTE THE QUALITY STANDARD OF THE DESIRED PRODUCT. ANY USE OF BRAND NAMES IS NOT INTENDED TO RESTRICT BIDDERS TO A SPECIFIC BRAND, MAKE, MANUFACTURER, OR NAME. THE BRAND NAMES / MANUFACTURERS OF MODELS ARE INTENDED TO CONVEY THE GENERAL STYLE, TYPE, CHARACTER, AND QUALITY OF PRODUCT. EQUIVALENT PRODUCTS WILL BE ACCEPTABLE IF THE PROJECT OWNER OR ENGINEER HAS GIVEN APPROVAL OF THE SPECIFIC PRODUCT IN WRITING. 44. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND PROVIDING STORAGE AREAS FOR CONSTRUCTION MATERIALS AND EQUIPMENT. THE MATERIAL AND EQUIPMENT STORAGE SHALL COMPLY WITH THE CONSTRUCTION DOCUMENTS AND ALL LOCAL, STATE AND FEDERAL REGULATIONS THROUGHOUT THE CONSTRUCTION PERIOD. THE CONTRACTOR SHALL RESTORE THE STORAGE AREA TO ITS ORIGINAL (OR BETTER) CONDITION UPON COMPLETION OF THE PROJECT OR UPON SUCH TIME AS DIRECTED BY THE PROJECT OWNER AND ENGINEER. SUCH RESTORATION SHALL BE AT NO ADDITIONAL COST TO THE PROJECT OWNER. 45. THE CONTRACTOR SHALL WARRANTY ALL MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF ACCEPTANCE OF BY THE PROJECT OWNER AND SHALL REPLACE ANY PORTIONS THAT FAIL DUE TO FAULTY MATERIALS OR WORKMANSHIP, AT NO ADDITIONAL COST TO THE PROJECT OWNER. A SIX (6) MONTH AND ELEVEN (11) MONTH INSPECTION WILL BE PERFORMED DURING THE WARRANTY PERIOD. THE CONTRACTOR SHALL IMMEDIATELY REPAIR ALL ITEMS DETERMINED BY THE PROJECT OWNER OR AUTHORIZED REPRESENTATIVE TO BE DEFECTIVE UPON NOTIFICATION. THE CONTRACTOR SHALL IMMEDIATELY REPAIR OR REPLACE FAILED ITEMS UPON NOTIFICATION BY THE PROJECT OWNER. SEASONALLY INSTALLED ITEMS SHALL BE REPAIRED OR REPLACED DURING THE NEXT AVAILABLE INSTALLATION PERIOD. ITEMS REPAIRED OR REPLACED UNDER THIS PROVISION SHALL HAVE AN ADDITIONAL ONE (1) YEAR WARRANTY PERIOD FROM THE NEW DATE OF ACCEPTANCE. AREAS AND/OR OTHER WORK DISTURBED WHILE ACCESSING AND/OR REPAIRING/REPLACING WARRANTY COVERED ITEMS SHALL BE STABILIZED. z ct 0 Z 0 co 0 g: UJ UJ W (D Q uj z Z Z _j 0 D 0 �_ 0 < c) 0� < 0 0 (D w < Lu 0 < Z LLJ LLJ LLJ Z LLJ 0 1 0 z 13� co C) LL Z 0 < C) Z < 0 W z 0 C) LL () Z LU 0 0- (D U) z 0 C) z < < W cl) LU Z F--- 0 0 (-) z ol� F--- 0 LL] () LL 0- Lu ) I­ 00 la� z Lu z Lu (D 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 DATE: 1/22/2024 NOT TO SCALE SHEET NUMBER 1.2 0_4 r-4 C) �q cy) �q cy) ,It 04 C) 04 cli N L, m m m _0 c 0 w 0 0 Lu 0 U) LLI 00 C.'4 Lo 6i 'IT N C) 04 cli 04 - cu 3 2 Q Lu U) U) 0 Ld 0 z 06 w Lu 0 U) GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITH THE NCGO1 CONSTRUCTION GENERAL PERMIT IMPLEMENTING THE DETAILS AND SPECIFICATIONS ON THIS PLAN SHEET WILL RESULT IN THE CONSTRUCTION ACTIVITY BEING CONSIDERED COMPLIANT WITH THE GROUND STABILIZATION AND MATERIALS HANDLING SECTIONS OF THE NCGO1 CONSTRUCTION GENERAL PERMIT (SECTIONS E AND F, RESPECTIVELY). THE PERMITTEE SHALL COMPLY WITH THE EROSION AND SEDIMENT CONTROL PLAN APPROVED BY THE DELEGATED AUTHORITY HAVING JURISDICTION. ALL DETAILS AND SPECIFICATIONS SHOWN ON THIS SHEET MAY NOT APPLY DEPENDING ON SITE CONDITIONS AND THE DELEGATED AUTHORITY HAVING JURISDICTION. SECTION E: GROUND STABILIZATION REQUIRED GROUND STABILIZATION TIMEFRAMES STABILIZE WITHIN THIS MANY SITE AREA DESCRIPTION CALENDAR DAYS AFTER TIMEFRAME VARIATIONS CEASING LAND DISTURBANCE (A) PERIMETER DIKES, SWALES, DITCHES, AND 7 NONE PERIMETER SLOPES (B) HIGH QUALITY WATER (HQW)ZONES 7 NONE (C) SLOPES STEEPER THAN 3:1 IF SLOPES ARE 10'OR LESS IN LENGTH AND 7 ARE NOT STEEPER THAN 2-1, 14 DAYS ARE ALLOWED (D) SLOPES 3-1 TO 4-1 - 7 DAYS FOR SLOPES GREATER THAN 50' IN LENGTH AND WITH SLOPES STEEPER THAN 4:1 14 - 7 DAYS FOR PERIMETER DIKES, SWALES, DITCHES, PERIMETER SLOPES AND HQW ZONES - 10 DAYS FOR FALLS LAKE WATERSHED (E) AREAS WITH SLOPES - 7 DAYS FOR PERIMETER DIKES, FLATTER THAN 4:1 SWALES, DITCHES, PERIMETER SLOPES 14 AND HQW ZONES - 10 DAYS FOR FALLS LAKE WATERSHED UNLESS THERE IS ZERO SLOPE NOTE: AFTER THE PERMANENT CESSATION OF CONSTRUCTION ACTIVITIES, ANY AREAS WITH TEMPORARY GROUND STABILIZATION SHALL BE CONVERTED TO PERMANENT GROUND STABILIZATION AS SOON AS PRACTICABLE BUT IN NO CASE LONGER THAN 90 CALENDAR DAYS AFTER THE LAST LAND DISTURBING ACTIVITY. TEMPORARY GROUND STABILIZATION SHALL BE MAINTAINED IN A MANNER TO RENDER THE SURFACE STABLE AGAINST ACCELERATED EROSION UNTIL PERMANENT GROUND STABILIZATION IS ACHIEVED. GROUND STABILIZATION SPECIFICATION STABILIZE THE GROUND SUFFICIENTLY SO THAT RAIN WILL NOT DISLODGE THE SOIL. USE ONE OF THE TECHNIQUES IN THE TABLE BELOW: TEMPORARY STABILIZATION PERMANENT STABILIZATION • TEMPORARY GRASS SEED COVERED e PERMANENT GRASS SEED COVERED WITH STRAW OR OTHER WITH STRAW OR OTHER MULCHES AND MULCHES AND TACKIFIERS TACKIFIERS 0 GEOTEXTILE FABRICS SUCH AS PERMANENT SOIL • HYDROSEEDING REINFORCEMENT MATTING • ROLLED EROSION CONTROL 9 HYDROSEEDING PRODUCTS WITH OR WITHOUT e SHRUBS OR OTHER PERMANENT PLANTINS COVERED WITH TEMPORARY GRASS SEED MULCH • APPROPRIATELY APPLIED STRAW OR 9 UNIFORM AND EVENLY DISTRIBUTED GROUND COVER OTHER MULCH SUFFICIENT TO RESTRAIN EROSION • PLASTIC SHEETING 0 STRUCTURAL METHODS SUCH AS CONCRETE, ASPHALT OR RETAINING WALLS 0 ROLLED EROSION CONTROL PRODUCTS WITH GRASS SEED POLYACRYLAMIDES (PAMS) AND FLOCCULANTS 1 SELECT FLOCCULANTS THAT ARE APPROPRIATE FOR THE SOILS BEING EXPOSED DURING CONSTRUCTION, SELECTING FROM THE NC DWR LIST OFAPPROVED PAMSIFLOCCULANTS. 2. APPLY FLOCCULANTS AT OR BEFORE THE INLETS TO EROSION AND SEDIMENT CONTROL MEASURES. 3. APPLY FLOCCULANTS AT THE CONCENTRATIONS SPECIFIED IN THE NC DWR LIST OF APPROVED PAMSIFLOCCULANTS AND IN ACCORDANCE WITH THE MANUFACTURIER'S INSTRUCTIONS. 4. PROVIDE PONDING AREA FOR CONTAINMENT OF TREATED STORMWATER BEFORE DISCHARGING OFFSITE. 5. STORE FLOCCULANTS IN LEAK -PROOF CONTAINERS THAT ARE KEPT UNDER STORM -RESISTANT COVER OR SURROUNDED BY SECONDARY CONTAINMENT STRUCTURES. EQUIPMENT AND VEHICLE MAINTENANCE 1 . MAINTAIN VEHICLES AND EQUIPMENT TO PREVENT DISCHARGE OF FLUIDS. 2. PROVIDE DRIP PANS UNDER ANY STORED EQUIPMENT. 3. IDENTIFY LEAKS AND REPAIR AS SOON AS FEASIBLE, OR REMOVE LEAKING EQUIPMENT FROM THE PROJECT. 4. COLLECT ALL SPENT FLUIDS, STORE IN SEPARATE CONTAINERS AND PROPERLY DISPOSE AS HAZARDOUS WASTE (RECYCLE WHEN POSSIBLE). 5. REMOVE LEAKING VEHICLES AND CONSTRUCTION EQUIPMENT FROM SERVICE UNTIL THE PROBLEM HAS BEEN CORRECTED. 6. BRING USED FUELS, LUBRICANTS, COOLANTS, HYDRAULIC FLUIDS AND OTHER PETROLEUM PRODUCTS TO A RECYCLING OR DISPOSAL CENTER THAT HANDLES THESE MATERIALS. LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE 1 . NEVER BURY OR BURN WASTE. PLACE LITTER AND DEBRIS IN APPROVED WASTE CONTAINERS. 2. PROVIDE A SUFFICIENT NUMBER AND SIZE OF WASTE CONTAINERS (E.G DUMPSTER, TRASH RECEPTACLE) ON SITE TO CONTAIN CONSTRUCTION AND DOMESTIC WASTES. 3. LOCATE WASTE CONTAINERS AT LEAST 50 FEET AWAY FROM STORM DRAIN INLETS AND SURFACE WATERS UNLESS NO OTHER ALTERNATIVES ARE REASONABLY AVAILABLE. 4. LOCATE WASTE CONTAINERS ON AREAS THAT DO NOT RECEIVE SUBSTANTIAL AMOUNTS OF RUNOFF FROM UPLAND AREAS AND DOES NOT DRAIN DIRECTLY TO A STORM DRAIN, STREAM OR WETLAND. 5. COVER WASTE CONTAINERS AT THE END OF EACH WORKDAY AND BEFORE STORM EVENTS OR PROVIDE SECONDARY CONTAINMENT. REPAIR OR REPLACE DAMAGED WASTE CONTAINERS. 6. ANCHOR ALL LIGHTWEIGHT ITEMS IN WASTE CONTAINERS DURING TIMES OF HIGH WINDS. 7. EMPTY WASTE CONTAINERS AS NEEDED TO PREVENT OVERFLOW. CLEAN UP IMMEDIATELY IF CONTAINERS OVERFLOW. 8. DISPOSE WASTE OFF -SITE AT AN APPROVED DISPOSAL FACILITY. 9. ON BUSINESS DAYS, CLEAN UP AND DISPOSE OF WASTE IN DESIGNATED WASTE CONTAINERS. PAINT AND OTHER LIQUID WASTE 1 . DO NOT DUMP PAINT AND OTHER LIQUID WASTE INTO STORM DRAINS, STREAMS OR WETLANDS. 2. LOCATE PAINT WASHOUTS AT LEAST 50 FEET AWAY FROM STORM DRAIN INLETS AND SURFACE WATERS UNLESS NO OTHER ALTERNATIVES ARE REASONABLY AVAILABLE. 3. CONTAIN LIQUID WASTES IN A CONTROLLED AREA. 4. CONTAINMENT MUST BE LABELED, SIZED AND PLACED APPROPRIATELY FOR THE NEEDS OF SITE. 5. PREVENT THE DISCHARGE OF SOAPS, SOLVENTS, DETERGENTS AND OTHER LIQUID WASTES FROM CONSTRUCTION SITES. PORTABLE TOILETS 1. INSTALL PORTABLE TOILETS ON LEVEL GROUND, AT LEAST 50 FEET AWAY FROM STORM DRAINS, STREAMS OR WETLANDS UNLESS THERE IS NO ALTERNATIVE REASONABLY AVAILABLE. IF 50 FOOT OFFSET IS NOT ATTAINABLE, PROVIDE RELOCATION OF PORTABLE TOILET BEHIND SILT FENCE OR PLACE ON A GRAVEL PAD AND SURROUND WITH SAND BAGS. 2. PROVIDE STAKING OR ANCHORING OF PORTABLE TOILETS DURING PERIODS OF HIGH WINDS OR IN HIGH FOOT TRAFFIC AREAS. 3. MONITOR PORTABLE TOILETS FOR LEAKING AND PROPERLY DISPOSE OF ANY LEAKED MATERIAL. UTILIZE A LICENSED SANITARY WASTE HAULER TO REMOVE LEAKING PORTABLE TOILETS AND REPLACE WITH PROPERLY OPERATING UNIT. EARTHEN STOCKPILE MANAGEMENT 1 . SHOW STOCKPILE LOCATIONS ON PLANS. LOCATE EARTH EN -MATERIAL STOCKPILE AREAS AT LEAST 50 FEET AWAY FROM STORM DRAIN INLETS, SEDIMENT BASINS, PERIMETER SEDIMENT CONTROLS AND SURFACE WATERS UNLESS IT CAN BE SHOWN NO OTHER ALTERNATIVES ARE REASONABLY AVAILABLE. 2. PROTECT STOCKPILE WITH SILT FENCE INSTALLED ALONG TOE OF SLOPE WITH A MINIMUM OFFSET OF FIVE FEET FROM THE TOE OF STOCKPILE. 3. PROVIDE STABLE STONE ACCESS POINT WHEN FEASIBLE. 4. STABILIZE STOCKPILE WITHIN THE TIMEFRAMES PROVIDED ON THIS SHEET AND IN ACCORDANCE WITH THE APPROVED PLAN AND ANY ADDITIONAL REQUIREMENTS. SOIL STABILIZATION IS DEFINED AS VEGETATIVE, PHYSICAL OR CHEMICAL COVERAGE TECHNIQUES THAT WILL RESTRAIN ACCELERATED EROSION ON DISTURBED SOILS FOR TEMPORARY OR PERMANENT CONTROL NEEDS. ONSITE CONCRETE WASHOUT STRUCTURE WITH LINER CLEARLY MARKED SIGNAGE NOTING DEVICE (18"x24" MIN.) NOTES: 1 . ACTUAL LOCATION DETERMINED IN FIELD. 2. THE CONCRETE WASHOUT STRUCTURES SHALL BE MAINTAINED WHEN THE LIQUID AND/OR SOLID REACHES 75% OF THE STRUCTURES CAPACITY. 3. CONCRETE WASHOUT STRUCTURE NEEDS TO BE CLEARY MARKED WITH SIGNAGE NOTING DEVICE. SANDBAGS (TYP.) OR STAPLES M 00- 1141 PLAN BELOW GRADE WASHOUT STRUCTURE NOT TO SCALE 1:1 SIDE SLOPE (TYP.) SILT FENCE (TYP.) 3.0' MIN. XXMAX, HIGH COHESIVE & 10, LOW CLEARLY MARKED HIGH COHESIVE & MIN. FILTRATION LOW FILTRATION SOIL BERM CONCRETE �31Qlljm%jF_ 114U 1 llN%j SOIL BERM B WASHOUT DEVICE (18"x24" MIN.) 0 0 o' 10, NOTES: 0 o' MIN. 1 . ACTUAL LOCATION DETERMINED IN FIELD. 10 c:;) E 0-' 2. THE CONCRETE WASHOUT STRUCTURES SHALL _2�j BE MAINTAINED WHEN THE LIQUID AND/OR SANDBAGS (TYP.) B SOLID REACHES 75% OF THE STRUCTURES OR STAPLES CAPACITY TO PROVIDE ADEQUATE HOLDING PLAN CAPACITY WITH A MINIMUM 12 INCHES OF FREEBOARD. 3. CONCRETE WASHOUT STRUCTURE NEEDS TO BE CLEARY MARKED WITH SIGNAGE NOTING DEVICE. ABOVE GRADE WASHOUT STRUCTURE NOT TO SCALE � CONCRETE WASHOUTS SANDBAGS (TYP.) OR STAPLES 10 MIL PLASTIC LINING SANDBAGS (TYP.) OR STAPLES 1:1 SIDE (���p E Typ-) L---I [- 2.0' 10MIL 3.0' MIN. PLASTIC XXMAX. LINING 1 . DO NOT DISCHARGE CONCRETE OR CEMENT SLURRY FROM THE SITE. 2. DISPOSE OF, OR RECYCLE SETTLED, HARDENED CONCRETE RESIDUE IN ACCORDANCE WITH LOCAL AND STATE SOLID WASTE REGULATIONS AND AT AN APPROVED FACILITY. 3. MANAGE WASHOUT FROM MORTAR MIXERS IN ACCORDANCE WITH THE ABOVE ITEM AND IN ADDITION PLACE THE MIXER AND ASSOCIATED MATERIALS ON IMPERVIOUS BARRIER AND WITHIN LOT PERIMETER SILT FENCE. 4. INSTALL TEMPORARY CONCRETE WASHOUTS PER LOCAL REQUIREMENTS, WHERE APPLICABLE. IF AN ALTERNATE METHOD OR PRODUCT IS TO BE USED, CONTACT YOUR APPROVAL AUTHORITY FOR REVIEW AND APPROVAL. IF LOCAL STANDARD DETAILS ARE NOT AVAILABLE, USE ONE OF THE TWO TYPES OF TEMPORARY CONCRETE WASHOUTS PROVIDED ON THIS DETAIL. 5. DO NOT USE CONCRETE WASHOUTS FOR DEWATERING OR STORING DEFECTIVE CURB OR SIDEWALK SECTIONS. STORMWATER ACCUMULATED WITHIN THE WASHOUT MAY NOT BE PUMPED INTO OR DISCHARGED TO THE STORM DRAIN SYSTEM OR RECEIVING SURFACE WATERS. LIQUID WASTE MUST BE PUMPED OUT AND REMOVED FROM PROJECT. 6. LOCATE WASHOUTS AT LEAST 50 FEET FROM STORM DRAIN INLETS AND SURFACE WATERS UNLESS IT CAN BE SHOWN THAT NO OTHER ALTERNATIVES ARE REASONABLY AVAILABLE. AT A MINIMUM, INSTALL PROTECTION OF STORM DRAIN INLET(S) CLOSEST TO THE WASHOUT WHICH COULD RECEIVE SPILLS OR OVERFLOW. 7. LOCATE WASHOUTS IN AN EASILY ACCESSIBLE AREA, ON LEVEL GROUND AND INSTALL A STONE ENTRANCE PAD IN FRONT OF THE WASHOUT. ADDITIONAL CONTROLS MAY BE REQUIRED BY THE APPROVING AUTHORITY. 8. INSTALL AT LEAST ONE SIGN DIRECTING CONCRETE TRUCKS TO THE WASHOUT WITHIN THE PROJECT LIMITS. POST SIGNAGE ON THE WASHOUT ITSELF TO IDENTIFY THIS LOCATION. 9. REMOVE LEAVINGS FROM THE WASHOUT WHEN AT APPROXIMATELY 75% CAPACITY TO LIMIT OVERFLOW EVENTS. REPLACE THE TARP, SAND BAGS OR OTHER TEMPORARY STRUCTURAL COMPONENTS WHEN NO LONGER FUNCTIONAL. WHEN UTILIZING ALTERNATIVE OR PROPRIETARY PRODUCTS, FOLLOW MANUFACTURER'S INSTRUCTIONS. 10. AT THE COMPLETION OF THE CONCRETE WORK, REMOVE REMAINING LEAVINGS AND DISPOSE OF IN AN APPROVED DISPOSAL FACILITY. FILL PIT, IF APPLICABLE, AND STABILIZE ANY DISTURBANCE CAUSED BY REMOVAL OF WASHOUT. � HERBICIDES, PESTICIDES AND RODENTICIDES 1. STORE AND APPLY HERBICIDES, PESTICIDES AND RODENTICIDES IN ACCORDANCE WITH LABEL RESTRICTIONS. 2. STORE HERBICIDES, PESTICIDES AND RODENTICIDES IN THEIR ORIGINAL CONTAINERS WITH THE LABEL, WHICH LISTS DIRECTIONS FOR USE, INGREDIENTS AND FIRST AID STEPS IN CASE OF ACCIDENTAL POISONING. 3. DO NOT STORE HERBICIDES, PESTICIDES AND RODENTICIDES IN AREAS WHERE FLOODING IS POSSIBLE OR WHERE THEY MAY SPILL OR LEAK INTO WELLS, STORMWATER DRAINS, GROUND WATER OR SURFACE WATER. IF A SPILL OCCURS, CLEAN AREA IMMEDIATELY. 4. DO NOT STOCKPILE THESE MATERIALS ONSITE. � HAZARDOUS AND TOXIC WASTE 1. CREATE DESIGNATED HAZARDOUS WASTE COLLECTION AREAS ON -SITE. 2. PLACE HAZARDOUS WASTE CONTAINERS UNDER COVER OR IN SECONDARY CONTAINMENT. 3. DO NOT STORE HAZARDOUS CHEMICALS, DRUMS OR BAGGED MATERIALS DIRECTLY ON THE GROUND. CL CL < z ct 0 co Z 0 co 0 g: UJ UJ W (D Q uj < Z Z z -:] Lu a_ 0 D 0 0 _j z < c) < ol� 0 0� < 0 (D LU 0 0 (D 3: z z �_ w D < �_ 0� - �: Lu (D Lu < 0 < 0� Z cl) �: Z - o 0 z LLj LLI 0 C) LLJ LLJ Z 0 O� 1 0 LLI 0 z 13� co (1) LL C) LL 0 z F___ 0 Z 0 z < z 0 (D 0 z 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 DATE: 1/22/2024 NOT TO SCALE SHEET NUMBER 1.3 Lo ul 6 L.0 cy) ,It 04 C) 04 cli N m cu _0 c 0 w 0 0 Lu 0 U) LLI 00 Lo 6i 'IT N C) 04 cli 04 - cu 3 2 Q Lu U) U) 0� r 0 0 U) w 0 z 06 w w 0 U) PART III SELF -INSPECTION, RECORDIKEEPING AND REPORTING SECTION A: SELF -INSPECTION SELF -INSPECTIONS ARE REQUIRED DURING NORMAL BUSINESS HOURS IN ACCORDANCE WITH THE TABLE BELOW. WHEN ADVERSE WEATHER OR SITE CONDITIONS WOULD CAUSE THE SAFETY OF THE INSPECTION PERSONNEL TO BE IN JEOPARDY, THE INSPECTION MAY BE DELAYED UNTIL THE NEXT BUSINESS DAY ON WHICH IT IS SAFE TO PERFORM THE INSPECTION. IN ADDITION, WHEN A STORM EVENT OF EQUAL TO OR GREATER THAN 1.0 INCH OCCURS OUTSIDE OF NORMAL BUSINESS HOURS, THE SELF -INSPECTION SHALL BE PERFORMED UPON THE COMMENCEMENT OF THE NEXT BUSINESS DAY. ANY TIME WHEN INSPECTIONS WERE DELAYED SHALL BE NOTED IN THE INSPECTION RECORD. FREQUENCY (DURING NORMAL INSPECT BUSINESS INSPECTION RECORDS MUST INCLUDE: HOURS) (1) DAILY DAILY RAINFALL AMOUNTS. RAIN GUAGE IF NO DAILY RAIN GUAGE OBSERVATIONS ARE MADE DURING MAINTAINED IN WEEKEND OR HOLIDAY PERIODS, AND NO INDIVIDUAL -DAY RAINFALL GOOD INFORMATION IS AVAILABLE, RECORD THE CUMULATIVE RAIN WORKING MEASUREMENT FOR THOSE UWATTENDED DAYS (AND THIS WILL ORDER DETERMINE IF A SITE INSPECTION IS NEEDED). DAYS ON WHICH NO RAINFALL OCCURRED SHALL BE RECORDED AS "ZERO." THE PERMITTEE MAY USE ANOTHER RAIN -MONITORING DEVICE APPROVED BY THE DIVISION. (2) AT LEAST ONCE PER 1. IDENTIFICATION OF THE MEASURES INSPECTED, E&SC 7 CALENDAR DAYS 2. DATE AND TIME OF THE INSPECTION, MEASURES AND WITHIN 24 3. NAME OF THE PERSON PERFORMING THE INSPECTION, HOURS OF A RAIN 4. INDICATION OF WHETHER THE MEASURES WERE OPERATING EVENT�! PROPERLY, 1.0 INCH IN 24 HOURS 5. DESCRIPTION OF MAINTENANCE NEEDS FOR THE MEASURE, 6. DESCRIPTION, EVIDENCE, AND DATE OF CORRECTIVE ACTIONS TAKEN. (3) AT LEAST ONCE PER 1. IDENTIFICATION OF THE DISCHARGE OUTFALLS INSPECTED, STORMWATER 7 CALENDAR DAYS 2. DATE AND TIME OF THE INSPECTION, DISCHARGE AND WITHIN 24 3. NAME OF THE PERSON PERFORMING THE INSPECTION, OUTFALLS HOURS OF A RAIN 4. INDICATION OF STORMWATER POLLUTION SUCH AS OIL SHEEN, (SDOs) EVENT�: FLOATING OR SUSOENDED SOLIDS OR DISCOLORATION, 1.0 INCH IN 24 HOURS 5. INDICATION OF VISIBLE SEDIMENT LEAVING THE SITE, 6. DESCRIPTION, EVIDENCE, AND DATE OF CORRECTIVE ACTIONS TAKEN. (4) AT LEAST ONCE PER IF VISIBLE SEDIMENTATION IS FOUND OUTSIDE SITE LIMITS, THEN A PERIMETER 7 CALENDAR DAYS RECORD OF THE FOLLOWING SHALL BE MADE: OF SITE AND WITHIN 24 1. ACTIONS TAKEN TO CLEAN UP OR STABILIZE THE SEDIMENT THAT HOURS OF A RAIN HAS LEFT THE SITE LIMITS, EVENT�! 2. DESCRIPTION, EVIDENCE, AND DATE OF CORRECTIVE ACTIONS 1.0 INCH IN 24 HOURS TAKEN,AND 3. AN EXPLANATION AS TO THE ACTIONS TAKEN TO CONTROL FUTURE RELEASES. (5) AT LEAST ONCE PER IF THE STREAM OR WETLAND HAS INCREASED VISIBLE STREAMS OR 7 CALENDAR DAYS SEDIMENTATION OR A STREAM HAS VISIBLE INCREASED TURBIDITY WETLANDS AND WITHIN 24 FROM THE CONSTRUCTION ACTIVITY, THEN A RECORD OF THE ONSITE OR HOURS OF A RAIN FOLLOWING SHALL BE MADE- OFFSITE EVENT�! 1. DESCRIPTION, EVIDENCE AND DATE OF CORRECTIVE ACTIONS (WHERE 1.0 INCH IN 24 HOURS TAKEN,AND ACCESSIBLE) 2. RECORDS OF THE REQUIRED REPORTS TO THE APPROPRIATE DIVISION REGIONAL OFFICE PER PART III, SECTION C, ITEM (2)(a) OF THIS PERMIT. (6) AFTER EACH PHASE 1. THE PHASE OF GRADING (INSTALLATION OF PERIMETER E&sc GROUND OF GRADING MEASURES, CLEARING AND GRUBBING, INSTALLATION OF STORM STABILIZATION DRAINAGE FACILITIES, COMPLETION OF ALL LAND -DISTURBING MEASURES ACTIVITY, CONSTRUCTION OR REDEVELOPMENT, PERMANENT GROUND COVER). 2. DOCUMENTATION THAT THE REQUIRED GROUND STABILIZATION MEASURES HAVE BEEN PROVIDED WITHIN THE REQUIRED TIMEFRAME OR AN ASSURANCE THAT THEY WILL BE PROVIDED AS SOON AS POSSIBLE. NOTE: THE RAIN INSPECTION RESETS THE REQUIRED 7 CALENDAR DAY INSPECTION REQUIREMENT. PART III SELF -INSPECTION, RECORDIKEEPING AND REPORTING SECTION B: RECORDIKEEPING 1. E&SC PLAN DOCUMENTATION THE APPROVED E&SC PLAN AS WELL AS ANY APPROVED DEVIATION SHALL BE KEPT ON THE SITE. THE APPROVED E&SC PLAN MUST BE KEPT UP-TO-DATE THROUGHOUT THE COVERAGE UNDER THIS PERMIT. THE FOLLOWING ITEMS PERTAINING TO THE E&SC PLAN SHALL BE KEPT ON SITE AND AVAILABLE FOR INSPECTION AT ALL TIMES DURING NORMAL BUSINESS HOURS. ITEM TO DOCUMENT DOCUMENTATION REQUIREMENTS (a) EACH E&SC MEASURE HAS BEEN INSTALLED AND INITIAL AND DATE EACH E&SC MEASURE ON A COPY DOES NOT SIGNIFICANTLY DEVIATE FROM THE OF THE APPROVED E&SC PLAN OR COMPLETE, DATE LOCATIONS, DIMENSIONS AND RELATIVE ELEVATIONS AND SIGN AN INSPECTION REPORT THAT LISTS EACH SHOWN ON THE APPROVED E&SC PLAN. E&SC MEASURE SHOWN ON THE APPROVED E&SC PLAN. THIS DOCUMENTATION IS REQUIRED UPON THE INITIAL INSTALLATION OF THE E&SC MEASURES OR IF THE E&SC MEASURES ARE MODIFIED AFTER INITIAL INSTALLATION. (b) A PHASE OF GRADING HAS BEEN COMPLETED. INITIAL AND DATE A COPY OF THE APPROVED E&SC PLAN OR COMPLETE, DATE AND SIGN AN INSPECTION REPORT TO INDICATE COMPLETION OF THE CONSTRUCTION PHASE. (c) GROUND COVER IS LOCATED AND INSTALLED IN INITIAL AND DATE A COPY OF THE APPROVED E&SC ACCORDANCE WITH THE APPROVED E&SC PLAN. PLAN OR COMPLETE, DATE AND SIGN AN INSPECTION REPORT TO INDICATE COMPLIANCE WITH APPROVED GROUND COVER SPECIFICATIONS. (d) THE MAINTENANCE AND REPAIR REQUIREMENTS COMPLETE, DATE AND SIGN AN INSPECTION REPORT. FOR ALL E&SC MEASURES HAVE BEEN PERFORMED. (e) CORRECTIVE ACTIONS HAVE BEEN TAKEN TO E&SC INITIAL AND DATE A COPY OF THE APPROVED E&SC MEASURES. PLAN OR COMPLETE, DATE AND SIGN AN INSPECTION REPORT TO INDICATE THE COMPLETION OF THE CORRECTIVE ACTION. 2. ADDITIONAL DOCUMENTATION TO BE KEPT ON SITE IN ADDITION TO THE E&SC PLAN DOCUMENTS ABOVE, THE FOLLOWING ITEMS SHALL BE KEPT ON THE SITE AND AVAILABLE FOR INSPECTORS AT ALL TIMES DURING NORMAL BUSINESS HOURS, UNLESS THE DIVISION PROVIDES A SITE -SPECIFIC EXEMPTION BASED ON UNIQUE SITE CONDITIONS THAT MAKE THIS REQUIREMENT NOT PRACTICAL: (a) THIS GENERAL PERMIT AS WELL AS THE CERTIFICATE OF COVERAGE, AFTER IT IS RECEIVED. (b) RECORDS OF INSPECTIONS MADE DURING THE PREVIOUS TWELVE MONTHS. THE PERMITTEE SHALL RECORD THE REQUIRED OBSERVATIONS ON THE INSPECTION RECORD FORM PROVIDED BY THE DIVISION OR A SIMILAR INSPECTION FORM THAT INCLUDES ALL THE REQUIRED ELEMENTS. USE OF ELECTRON ICALLY-AVAI LABLE RECORDS IN LIEU OF THE REQUIRED PAPER COPIES WILL BE ALLOWED IF SHOWN TO PROVIDE EQUAL ACCESS AND UTILITY AS THE HARD -COPY RECORDS. 3. DOCUMENTATION TO BE RETAINED FOR THREE YEARS ALL DATA USED TO COMPLETE THE E-NOI AND ALL INSPECTION RECORDS SHALL BE MAINTAINED FOR A PERIOD OF THREE YEARS AFTER PROJECT COMPLETION AND MADE AVAILABLE UPON REQUEST. [40 CFR 122.411 PART 11, SECTION G, ITEM (4) DRAW DOWN OF SEDIMENT BASINS FOR MAINTENANCE OR CLOSE OUT SEDIMENT BASINS AND TRAPS THAT RECEIVE RUNOFF FROM DRAINAGE AREAS OF ONE ACRE OR MORE SHALL USE OUTLET STRUCTURES THAT WITHDRAW WATER FROM THE SURFACE WHEN THESE DEVICES NEED TO BE DRAWN DOWN FOR MAINTENANCE OR CLOSE OUT UNLESS THIS IS INFEASIBLE. THE CIRCUMSTANCES IN WHICH IT IS NOT FEASIBLE TO WITHDRAW WATER FROM THE SURFACE SHALL BE RARE (FOR EXAMPLE, TIMES WITH EXTENDED COLD WEATHER). NON -SURFACE WITHDRAWALS FROM SEDIMENT BASINS SHALL BE ALLOWED ONLY WHEN ALL OF THE FOLLOWING CRITERIA HAVE BEEN MET: (a) THE E&SC PLAN AUTHORITY HAS BEEN PROVIDED WITH DOCUMENTATION OF THE NON -SURFACE WITHDRAWAL AND THE SPECIFIC TIME PERIODS OR CONDITIONS IN WHICH IT WILL OCCUR. THE NON -SURFACE WITHDRAWAL SHALL NOT COMMENCE UNTIL THE E&SC PLAN AUTHORITY HAS APPROVED THESE ITEMS, (b) THE NON -SURFACE WITHDRAWAL HAS BEEN REPORTED AS AN ANTICIPATED BYPASS IN ACCORDANCE WITH PART 111, SECTION C, ITEM (2)(C) AND (D) OF THIS PERMIT, (c) DEWATERING DISCHARGES ARE TREATED WITH CONTROLS TO MINIMIZE DISCHARGES OF POLLUTANTS FROM STORMWATER THAT IS REMOVED FROM THE SEDIMENT BASIN. EXAMPLES OF APPROPRIATE CONTROLS INCLUDE PROPERLY SITED, DESIGNED AND MAINTAINED DEWATERING TANKS, WEIR TANKS, AND FILTRATION SYSTEMS, (d) VEGETATED, UPLAND AREAS OF THE SITES OR A PROPERLY DESIGNED STONE PAD IS USED TO THE EXTENT FEASIBLE AT THE OUTLET OF THE DEWATERING TREATMENT DEVICES DESCRIBED IN ITEM (C) ABOVE, (e) VELOCITY DISSIPATION DEVICES SUCH AS CHECK DAMS, SEDIMENT TRAPS, AND RIPRAP ARE PROVIDED AT THE DISCHARGE POINTS OF ALL DEWATERING DEVICES, AND (f) SEDIMENT REMOVED FROM THE DEWATERING TREATMENT DEVICES DESCRIBED IN ITEM (C) ABOVE IS DISPOSED OF IN A MANNER THAT DOES NOT CAUSE DEPOSITION OF SEDIMENT INTO WATERS OF THE UNITED STATES. PART III SELF -INSPECTION, RECORDIKEEPING AND REPORTING SECTION C: REPORTING 1. OCCURRENCES THAT MUST BE REPORTED PERMITTEES SHALL REPORT THE FOLLOWING OCCURRENCES: (a) VISIBLE SEDIMENT DEPOSITION IN A STREAM OR WETLAND. (b) OIL SPILLS IF: • THEY ARE 25 GALLONS OR MORE, • THEY ARE LESS THAN 25 GALLONS BUT CANNOT BE CLEANED UP WITHIN 24 HOURS, • THEY CAUSE SHEEN ON SURFACE WATERS (REGARDLESS OF VOLUME), OR • THEY ARE WITHIN 100 FEET OF SURFACE WATERS (REGARDLESS OF VOLUME). (C) RELEASES OF HAZARDOUS SUBSTANCES IN EXCESS OF REPORTABLE QUANTITIES UNDER SECTION 311 OF THE CLEAN WATER ACT (REF- 40 CFR 110.3 AND 40 CFR 117.3) OR SECTION 102 OF CERCLA (REF- 40 CFR 302.4) OR G.S. 143-215.85. (d) ANTICIPATED BYPASSES AND UNANTICIPATED BYPASSES. (e) NONCOMPLIANCE WITH THE CONDITIONS OF THIS PERMIT THAT MAY ENDANGER HEALTH OR THE ENVIRONMENT. 2. REPORTING TIMEFRAMES AND OTHER REQUIREMENTS AFTER A PERMITTEE BECOMES AWARE OF AN OCCURRENCE THAT MUST BE REPORTED, HE SHALL CONTACT THE APPROPRIATE DIVISION REGIONAL OFFICE WITHIN THE TIMEFRAMES AND IN ACCORDANCE WITH THE OTHER REQUIREMENTS LISTED BELOW. OCCURRENCES OUTSIDE NORMAL BUSINESS HOURS MAY ALSO BE REPORTED TO THE DEPARTMENT'S ENVIRONMENTAL EMERGENCY CENTER PERSONNEL AT (800) 858-0368. REPORTING TIMEFRAMES (AFTER DISCOVERY) AND OTHER OCCURRENCE REQUIREMENTS (a) VISIBLE SEDIMENT 9 WITHIN 24 HOURS, AN ORAL OR ELECTRONIC NOTIFICATION. DEPOSITION IN A STREAM o WITHIN 7 CALENDAR DAYS, A REPORT THAT CONTAINS A DESCRIPTION OF THE OR WETLAND SEDIMENT AND ACTIONS TAKEN TO ADDRESS THE CAUSE OF THE DEPOSITION. DIVISION STAFF MAY WAIVE THE REQUIREMENT FOR A WRITTEN REPORT ON A CASE -BY -CASE BASIS. 9 IF THE STREAM IS NAMED ON THE NC 303(d) LIST AS IMPAIRED FOR SEDIMENT -RELATED CAUSES, THE PERMITTEE MAY BE REQUIRED TO PERFORM ADDITIONAL MONITORING, INSPECTIONS OR APPLY MORE STRINGENT PRACTICES IF STAFF DETERMINE THAT ADDITIONAL REQUIREMENTS ARE NEEDED TO ASSURE COMPLIANCE WITH THE FEDERAL OR STATE IMPAIRED -WATERS CONDITIONS. (b) OIL SPILLS AND o WITHIN 24 HOURS, AN ORAL OR ELECTRONIC NOTIFICATION. THE NOTIFICATION RELEASE OF HAZARDOUS SHALL INCLUDE INFORMATION ABOUT THE DATE, TIME, NATURE, VOLUME AND SUBSTANCES PER ITEM LOCATION OF THE SPILL OR RELEASE. 1 (b)-(c) ABOVE (c) ANTICIPATED o A REPORTATLEAST TEN DAYS BEFORE THE DATE OF THE BYPASS, IF BYPASSES [40 CFR POSSIBLE. 122.41 (m)(3)] THE REPORT SHALL INCLUDE AN EVALUATION OF THE ANTICIPATED QUALITY AND EFFECT OF THE BYPASS. (d) UNANTICIPATED o WITHIN 24 HOURS, AN ORAL OR ELECTRONIC NOTIFICATION. BYPASSES [40 CFR 9 WITHIN 7 CALENDAR DAYS, A REPORT THAT INCLUDES AN EVALUATION OF THE 122.41 (m)(3)] QUALITY AND EFFECT OF THE BYPASS. (e) NONCOMPLIANCE WITH 9 WITHIN 24 HOURS, AN ORAL OR ELECTRONIC NOTIFICATION. THE CONDITIONS OF THIS o WITHIN 7 CALENDAR DAYS, A REPORT THAT CONTAINS A DESCRIPTION OF THE PERMIT THAT MAY NONCOMPLIANCE, AND ITS CAUSES; THE PERIOD OF NONCOMPLIANCE, ENDANGER HEALTH OR INCLUDING EXACT DATES AND TIMES, AND IF THE NONCOMPLIANCE HAS NOT THE ENVIRONMENT [40 BEEN CORRECTED, THE ANTICIPATED TIME NONCOMPLIANCE IS EXPECTED TO CFR 122.41(10(7)] CONTINUE; AND STEPS TAKEN OR PLANNED TO REDUCE, ELIMINATE, AND PREVENT REOCCURRENCE OF THE NONCOMPLIANCE. [40 CFR 122.41(l)(6). o DIVISION STAFF MAY WAIVE THE REQUIREMENT FOR A WRITTEN REPORT ON A CASE -BY -CASE BASIS. co 0 ui ui (D Q 0 z 0 Lu 0� z 0 0 c/) LLI LL] w 121� 0 z Z _j D 0 0 c) < 0 (D < 0 < Z Lu z LLJ 0 1 0 13� co C) LL Z 0 C) Z 0� �: < 0 (D z LLI a_ Lu a_ _j z < 0 cl� - LLI z 0 Lu Z) (D z cl) 0 z 0 C) 0 LL z 0 0 z (D 0 z 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 DATE: 1/22/2024 NOT TO SCALE SHEET NUMBER 1.4 LEGEND �_F 04 C) 9 C) 1p C) 04 C) 04 cli N Ll m m m _0 c 0 w 0 C) Lu U) LLI 00 N C) 04 04 04 - cu 3 5 Q Lu U) U) 0� r Ld 0 z 06 w Lu 0 U) PLAN LEGEND DESIGN STREAM CENTERLINE DESIGN BANKFULL DESIGN MAJOR CONTOUR DESIGN MINOR CONTOUR DESIGN FLOODPLAIN TOE EXISTING STREAM CENTERLINE EXISTING TOP OF BANK BL, EXISTING BOTTOM OF BANK EXISTING MAJOR CONTOUR - - - - - - - - - EXISTING MINOR CONTOUR EXISTING WETLAND PROPERTY LINE - - - - - - - RIGHT OF WAY ROAD & PATH EDGE ELECTRIC UTILITY LINES SAN — SANITARY SEWER LINE SANITARY SEWER STRUCTURE FWAY— FEMA FLOODWAY _100YR— 100 YR. FEMA FLOODPLAIN 500 YR 500 YR. FEMA FLOODPLAIN TOPOGRAPHIC SURVEY LIMITS TYPICAL SECTIONS '7 STRUCTURE LEGEND DESIGN CONSTRUCTED RIFFLE DESIGN TOE WOOD DESIGN LOG VANE DESIGN LOG J-HOOK VANE DESIGN BOULDER J-HOOK 171 ff'-j I �r=-j I �r=-j I �l DESIGN CHANNEL PLUG �LLLLLLL� DESIGN FLOODPLAIN DEPRESSION DESIGN BRIDGE CROSSING EXISTING CULVERT CROSSING I FLOODPLAIN WIDTH VARIES PER PLAN PROPOSED EROSION FLOODPLAIN (TYP. 20: 1) CONTROL MATTING BKF WSE '3' 3' PROPOSED GRADE DMAX-IB TYPICAL RIFFLE CROSS SECTION FLOODPLAIN (TYP 20-1) PROPOSED CENTERLINE ALIGNMENT PROFILE LEGEND DESIGN STREAM THALWEG DESIGN BANKFULL EXISTING GROUND BOULDER STRUCTURE TIE TO EXISTING WBKF PER GRADING PLAN INNER IN (Typ, 201) DMAX BERM FLOODPLA WIB 0.91 IB WSE MAX DEPTH AT CENTER OF RIFFLE CROSS-SECTION I FLOODPLAIN VVIL) I H VARIES PER PLAN POINT BAR zz RIFFLE CROSS-SECTION SUMMARY PARAMETER PARAMETER ABKF (FT 2) 25.4 AlB (FT 2) 8.6 WBKF (FT) 21.4 WIB (FT) 10.0 DBKF (FT) 1.19 DIB (FT) 0.86 DMAX (FT) 2.1 DMAMB (FT) 1.2 W/D 18.0 WIB/DIB 11.6 DMAX/DBKF 1.77 DMAX-IB/DIB 1.40 SO (FT/FT) 0.012 AIB/ABKF 0.34 r� N TIE TO EXISTING WPOOL 'JK/ PROPOSED EROSION PER GRADING PLAN BKF WSE CONTROL MATTING FLOODPLAIN Yp, 201) 1. 8' Dmp OOL 91 3.9' PROPOSED CENTERLINE ALIGNMENT BANK TREATMENT PER PLAN & PROFILE SHEET(S) NOT TO SCALE POOL CROSS-SECTION SUMMARY PARAMETER ApOOL(FT 2) 44.5 WPOOL (FT) 25.7 DpOOL(FT) 1.7 DMPOOL(FT) 3.7 ApOOL/ABKF 1.75 WPOOL/WBKF 1.20 DMPOOL/DBKF 3.1 EROSION AND SEDIMENTATION CONTROL LEGEND LOD LIMITS OF DISTURBANCE SF SILT FENCE -C]-- CONSTRUCTION SAFETY FENCE TB TROUT BUFFER STAGING AND STORAGE AREA EROSION CONTROL MATTING STABILIZED CONSTRUCTION ENTRANCE CONSTRUCTION ACCESS ROUTE TEMPORARY BRIDGE CROSSING F9 8LWORKARFAI T TEMPORARY PUMP AROUND p >__ TEMPORARY TIMBER MAT RE -VEGETATION LEGEND ZONE 1 - STREAMBANKS 0 0 0:� ZONE 2 - RIPARIAN BUFFER ZONE 3 - UPLAND TYPICAL CROSS-SECTION NOTES 1. CONSTRUCT CROSS -SECTIONS TO THE LINES, ELEVATIONS AND GRADES SHOWN ON THE PLAN, PROFILE, AND DETAILS. 2. INSTALL STREAM RESTORATION STRUCTURES IN PROPOSED CHANNEL TO THE ELEVATIONS AND GRADES SHOWN ON THE PLAN, PROFILE AND DETAILS. RE -DRESSING OF CHANNEL AND BANKFULL BENCH/FLOODPLAIN WILL LIKELY BE REQUIRED FOLLOWING INSTALLATION OF IN -STREAM STRUCTURES AND SHALL BE CONSIDERED INCIDENTAL TO CONSTRUCTION. 3. INSTALL EROSION CONTROL MATTING ON ALL GRADED OR DISTURBED STREAMBANKS. z ct 0 m Z 0 co 0 g: UJ UJ W (D uj z Z Z -:] 0 D 0 �z 0 < c) 0� < 0 (D C/) < Lu 0 < Z LLj LLJ LLJ Z LLJ 0 1 0 z 13� co C) LL K 0 < C) Z < 0 r U) z z 00 I— — (D C) z LLI C) Z 0-0 2i O� 06 0 LLJ C) LL Z I_ Lu 0 (D Z Lu _j 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 DATE: 1/22/2024 NOT TO SCALE TYPICAL POOL CROSS SECTION NOT TO SCALE SHEET NUMBER 1.5 DANIEL BOONE DR EXT THE GREENWAY TRAIL C\j 6 CD 6 � 'I-, CN CD N 01-110 0 w F- 0 uj w CC) �i co �q 0) It C14 C) C14 CN CN L, cu cu 2 0 w U) r U) PR HARDIN CREEK GO PIONEERS DR IV 17t WATAUGA HIGH SCHOOL SOUTH FORK NEW RIVER co Z 0 co g: 0 LLJ U) LLJ W Q LU 0 0� CL IL > w z Z Z _j 0 D 0 0 0� z �z < c) < z 0 < C) (D < 0 �- (D D 3: �- Z -i a- C/) Lu < 0� 0 �: < LLJ F— < �: Z — U) cl) Z LL] Ld 0 LLJ LLJ Z 0 C) Lu 0 LLJ Lu 0 z 13� co 0- > LL C) LL 0 1-- Z 0 0 < C) z < 0 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 0 + 10, lo, ool c\1 c\1 0 c/) C/) LU LU lo, dol lo, lo, THE GREENWAY TRAIL BRIDGE. SEE SHEET 2.7 DATE: 1/22/2024 SCALE (34"X22"): 1" = loo' SCALE (1 7"Xl 1 "): 1 " = 200' 0 100 200 SCALE IN FEET SHEET NUMBER 2.1 .......... . ... .... . ­5 Z�7 --:—:7 '.Z_ '\X -Zz -=Z < Z 7— _5 Z— VRE _-Z NN, N 50QYR jl J, J� ;ig �7_� Ay RE�!Z + o o SAN --------------- - _j A IN looYp FWA-y _577_olm - iFw— N y- —r- -Ao 0. < 00 ()0,— ply_ T_ ZZ V. \/v > CD i P_ J-6 — — ---- S�' oA T -7n, '-fou C) FWAY 10— /Z E WAY 5+00 ------------ _SO4 04 Ire- C) 04 'VA GIB 10 ci _7 N D p /ol 1+0,0 r-.7 N R, iL 7*n e.1 -,1- 11.1 �y CU kf _0 ply A > BEGIN HARDIN CREErx 0 c> A Z REALIGNMENT ....................... N Iv TYP. CONSTRUCTED RIFFLE Lu I OOYR -i — < 0 TYP. LOG VANE 0I TYP. TOE WOOD w 00 00 .4 04 C) 04 cli N 5 0 w co cn 0� r 0 z r 3120 3115 3110 3105 3100 0+00 I 1+00 2+00 3+00 PR HARDIN CREEK - SCALE: HOR 1 " = 30'; VERT 1 " = 3' 4+00 5+00 6+00 c 3120 3115 3110 3105 3100 NOTES: � a_ 2 1. CONTRACTOR TO IDENTIFY AND 0 PROTECT EX. UTILITIES. z ct 0 2. DISTURBANCE OF WETLANDS, TREES, AND/OR WOODY VEGETATION ED 0 �.: Z 0 SHALL BE KEPT TO MINIMUM EXTENT co PRACTICAL TO COMPLETE WORK. 3. RESTORE ACCESS PATHS AND STORAGE AREA(S) TO ORIGINAL m CONDITION UPON COMPLETION OF uj THE PROJECT OR UPON SUCH TIME AS DIRECTED BY THE PROJECT OWNER AND ENGINEER. 4. ON -SITE ROCK MATERIAL MAY BE REUSED FOR STRUCTURES, AT THE < z C) C) DIRECTION OF THE ENGINEER. Z Z + co D 0 0 z 5. CONSTRUCTED RIFFLE CAN BE < 0 1­0 C) REPLACED WITH WOODY RIFFLE OR 0� 0 < (D m (D Z C) + ENHANCED HABITAT RIFFLE, AT THE co < < APPROVAL OF THE ENGINEER. w �- < 0 < 0� [-.- U) cQ �: Z - 0 �e Z 0 6. TOE WOOD TO EXTEND 10'INTO W W uj Z UJ UJ C) DOWNSTREAM RIFFLE BANK. TOE W 0 O� O� WOOD CAN BE REPLACED WITH z 0 co w a- (j z 0 u- ROCK TOE, AT THE APPROVAL OF u- 0 0 THE ENGINEER. < Z Z < z 7. FLOODPLAIN DEPRESSIONS TO NOT 0 EXCEED 18" BELOW BANKFULL ELEVATION. LOCATION SUBJECT TO CHANGE AT THE DIRECTION OF THE ENGINEER. 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 DATE: 1/22/2024 SCALE (34"X22"): 1 if = 30' SCALE (17"Xll"): 111=60' 0 30 60 SCALE IN FEET SHEET NUMBER NOT TO SCALE 2.2 �_F C) 04 C) C'� IN M D c M M _0 c 0 Lu Ij _j 0- C) w 00 00 �q 0) It c\1 C) c\1 C4 04 L, cu cu 2 0 w U) r U) NOTES: f 1. CONTRACTOR TO IDENTIFY AND Y "oo�� 'S'al PROTECT EX. UTILITIES. j- I I y1j A� p- SAN A N c SAN 0=% MIN a .0 a M 2. DISTURBANCE OF WETLANDS, all momom TREES, AND/OR WOODY VEGETATION ME SHALL BE KEPT TO MINIMUM EXTENT ED PRACTICAL TO COMPLETE WORK. 3. RESTORE ACCESS PATHS AND STORAGE AREA(S) TO ORIGINAL CONDITION UPON COMPLETION OF NameISH a A moon ammummomm a THE PROJECT OR UPON SUCH TIME MENNEN AS DIRECTED BY THE PROJECT Sol Now .... man OWNER AND ENGINEER. NO ........ .......... 4. ON —SITE ROCK MATERIAL MAY BE REUSED FOR STRUCTURES, AT THE Ag DIRECTION OF THE ENGINEER. mosommommi! A ITS & M 5. CONSTRUCTED RIFFLE CAN BE REPLACED WITH WOODY RIFFLE OR 011 *1 'am ...... 0 ......... 01 ; ENHANCED HABITAT RIFFLE, AT THE APPROVAL OF THE ENGINEER. 000000000ME am on =MENOMONEE nommommilim MONOMER MEEMEEMEMEME 6. TOE WOOD TO EXTEND 10'INTO a M-nommommomm Ems DOWNSTREAM RIFFLE BANK. TOE C-i WOOD CAN BE REPLACED WITH ROCK TOE, AT THE APPROVAL OF MUM: w in ums 1011 a THE ENGINEER. Noses OEM Is ONE man 0 no 0 Ems 'NONE No so a a 0-10118mmom --- ge-RUM: 6+00 3110 3105 3100 3095 3090 6+00 7+00 We ffiff 9+00 10+00 11+00 7+00 8+00 9+00 10+00 11+00 PR HARDIN CREEK — SCALE: HOR 1 30'; VERT 1 3' 12+00 3110 3105 3100 3095 3090 12+00 �:;i ( 11 _'% F11111111110-ODPLAIN DEP % � . 111�) TO 0 1 EXCEED 18" BELOW BANKFULL ELEVATION. LOCATION SUBJECT TO CHANGE AT THE DIRECTION OF THE ENGINEER. Q Lu 0 0� > CL W IL z Z Z -:] 0 D 0 �_ u 0� < c) < 0� < C) 0 (D C/) < Lu 0 < Z LLJ LLJ LLJ Z LLJ 0 1 0 z 13� 00 C) LL Z 0 < C) Z k< 0 i I i I i I i I i I i C) C) N 9r- 0 z F--- 0 (D C:) c) z + Qc) U) cf) Z 0 LLI Lu Lr- LLJ U LL I— 00 z n 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 DATE: 1/22/2024 SCALE (34"X22"): 1 if = 30' SCALE (17"X11"): 111=60' 0 30 60 SCALE IN FEET SHEET NUMBER 2.3 NOT TO SCALE 2 0 w U) 0 z U) Z­ NOTES: . ........ 1111111,"'.111- . . ....... 1. CONTRACTOR TO IDENTIFY AND 50 Ills- -Y TYP. CHANNEL PLUG --A/VA TA PROTECT EX. UTILITIES. N.- M. W­ wo w i t - E-L-ja w im � —iff w- ---------- -DE-E-a K- O-PG- 445,:7,--,- 2. DISTURBANCE OF WETLANDS, TREES, AND/OR WOODY VEGETATION SHALL BE KEPT TO MINIMUM EXTENT PRACTICAL TO COMPLETE WORK. 3. RESTORE ACCESS PATHS AND STORAGE AREA(S) TO ORIGINAL jalls. CONDITION UPON COMPLETION OF Mw a A, THE PROJECT OR UPON SUCH TIME AS DIRECTED BY THE PROJECT Itj!E� OEM— 4A�a I AM k -­N OWNER AND ENGINEER. 41"Y 1 10, ­-Z", 4. ON -SITE ROCK MATERIAL MAY BE C) Iva C) REUSED FOR STRUCTURES, AT THE + z 00 DIRECTION OF THE ENGINEER. Ir- 5. CONSTRUCTED RIFFLE CAN BE < CD (D REPLACED WITH WOODY RIFFLE OR 0 (D 3: z + 0 �- D �- — N Z) ENHANCED HABITAT RIFFLE, AT THE C/) < 0� �: -r-- ()� yj �- 0 < < I— APPROVAL OF THE ENGINEER. < c/) munissit, C) z sm.111 a 0 gas Uj 0 SOON LIJ I annual Sun ME 6. TOE WOOD TO EXTEND 10'INTO — Uj C) Samoa ISO Viggo Sasso z I LIJ mi, asset's asses:ggle I Uj gus Uj 0 DOWNSTREAM RIFFLE BANK. TOE .--*unsung" Uj somes�al i.1-i IS!; alsolik Uj .141 as Sol Sassoula U- a a WOOD CAN BE REPLACED WITH z stiostis onsici� unsung a is a_ won 0 U— z is SON ME isitsoll I M ROCK TOE AT THE APPROVAL OF a., L IN-WIS 5 - 1 � a Z 0 0 SOON a low Samoan THE ENGINEER. Z < Z ON— I MINIMUM ;*wool me a 0-SI.R. a __-_-as ON 1�� as sams"I ME - I'll" ,SON; an nwasm: aw 7. FLOODPLAIN DEPRESSIONS TO NOT EXCEED 18" BELOW BANKFULL ELEVATION. LOCATION SUBJECT TO CHANGE AT THE DIRECTION OF THE ENGINEER. 3105 3100 3095 3090 3085 12+00 13+00 14+00 15+00 PR HARDIN CREEK - SCALE: HOR 1 " = 30'; VERT 1 " = 3' 16+00 17+00 3105 3100 3095 3090 3085 18+00 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 DATE: 1/22/2024 SCALE (34"X22"): 1 if = 30' SCALE (17"X11"): 111=60' 0 30 60 SCALE IN FEET SHEET NUMBER 2.4 NOT TO SCALE . .... CONNECT STORMWATER OUTFALLS v i riv- TO HARDIN CREEK. TYP 3'BOTTOM A -;- WITH 3:1 SIDE SLOPES 71 Z) �0' '0' -mv Iwo N \ io Ur 'A FWA y-, Q-1 F� _%__ " I '�T- -- -" 11 , '�" , I � ___ - , a.- q7q�-ft_�m — I WA �&Z AWL A" N, 0:007 OmmmmofforA ON immmoommomw4l"Now ON smomommoomm, INS Smommmirman M 0 ONES ON I no ON SO ENE SEEM Ommummal --- No SOME 10001 MOM 00 No IS No No ME IS I Mom Now SOMEONE 111111MUM: 11UH: ii MUN ON ON ,'MENEM IONIC'S so mumom I SOON 0 mom so . I i .0.0.0.0.0 So NOTES: � a_ 2 0 1. CONTRACTOR TO IDENTIFY AND PROTECT EX. UTILITIES. z ct 0 2. DISTURBANCE OF WETLANDS, ED 0 Z TREES, AND/OR WOODY VEGETATION 0 SHALL BE KEPT TO MINIMUM EXTENT PRACTICAL TO COMPLETE WORK. MAY 77� 4a j�o il'-i ------ )j 3 11, ""Ir4vt% I ;T f I A —T p ct) 01 01 Je ol "W' IL o"r Airlso'N"?, L , i I X- PAO Nook MR. -T-1 I > " 'u 't.wN, 'v� 'A� '40 -xw- % '00 04 7 C) A�f C) F CD 0 04 4. PPT 0) WAY C> Fp r m 00'', +rrt- N 2�1 ii TTI I 1 7' ------- -- - tit - i ,-,a m 1\ FPT 00 -oo� FPT m m fttftL 5. 0 FWAY \N _Rffi 0 or -i __�_ TYP. LOG VANE w"w TYP. LOG 7 'I,— o— J-HOOK VANE locs TYP. TOE WOOD 6. Mae Lu TYP. CONSTRUCTED RIFFLE 100YR ----- -------------------- 1 500YR TYP. CHANNEL PLUG 5 0 w U) U) 0� r z r U) 500yR 18+00 19+00 20+00 21+00 22+00 23+00 24+00 3100 3095 3090 3085 mm 18+00 19+00 20+00 21+00 PR HARDIN CREEK — SCALE: HOR 1 30'; VERT 1 3' 22+00 23+00 3100 3095 3090 3085 mm 24+00 RESTORE ACCESS PATHS AND STORAGE AREA(S) TO ORIGINAL CONDITION UPON COMPLETION OF THE PROJECT OR UPON SUCH TIME AS DIRECTED BY THE PROJECT OWNER AND ENGINEER. ON —SITE ROCK MATERIAL MAY BE REUSED FOR STRUCTURES, AT THE DIRECTION OF THE ENGINEER. CONSTRUCTED RIFFLE CAN BE REPLACED WITH WOODY RIFFLE OR ENHANCED HABITAT RIFFLE, AT THE APPROVAL OF THE ENGINEER. TOE WOOD TO EXTEND 10'INTO DOWNSTREAM RIFFLE BANK. TOE WOOD CAN BE REPLACED WITH ROCK TOE, AT THE APPROVAL OF THE ENGINEER. 7. FLOODPLAIN DEPRESSIONS TO NOT EXCEED 18" BELOW BANKFULL ELEVATION. LOCATION SUBJECT TO CHANGE AT THE DIRECTION OF THE ENGINEER. < z -:] + I- Z Z N 0 D 0 0 0 z �z < 0 1— 0 < (D C) C) 0 (D D 3: �_ z + 00 C/) < 0� �: V-- yj �- < 0 < 0� < F--- ct) �: Z - o z uj uj 0 C) LIJ UJ z 0 uj O� 0 ui o co a_ U- u- z I_ Z 0 0 < Z Z 3: �: < < 0 a_ 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 DATE: 1/22/2024 SCALE (34"X22"): 1 if = 30' SCALE (17"X11"): 111=60' 0 30 60 SCALE IN FEET SHEET NUMBER 2.5 NOT TO SCALE 61 " %T � \\ %..,, 1,�� \ t I I 4;1 i� 'a I i —_ I j Af .,I JA,, % klt % f 14.F y 1 N',\ i"i f A, i 104 1, K I v 4— z5— f j \17 r —A IF If v r$ X/ tP, te j /f Al f f 0 — — — — — — — — —T -<zz e-11 SAN SAN Z 7SA N SAN SAN �J"',j'\ L SAN S SAN c7WAY T FWAY F-WAY v lot FPT FPT 7 It C.) _7�7 9_7 Z5 X, cv) (3085) r *,\\"",x", x 00 C) co TIE OUT TO SOUTH _TIOB co cv) FORK NEW RIVER ��l C) '7� C) "All 25+00 C) 04 GRADE BANKS 4:1 C4 N IN m DOWNSTREAM OF D SEWER CROSSING PT FP-r cu _0 T - ------ c My Fp-Tr MIX OF NCDOT CLASS 1 L /1 O'a FWAy & CLASS B ROCK TO w 0 BE PACKED AROUND r-rx OrMuk0c PIERS IN CHANNEL SEE SHEET 2.7 TYP. CONSTRUCTED RIFFLE _ZF 4 --1 BOULDER J-HOOK. CHANNEL -10 1211� TYP. LOG J-HOOK VANE BED ON RIGHT SIDE TO BE 0 HIGHER THAN LEFT. .5 10 TYP. TOE WOOD co TYP. CHANNEL PLUG m I Lu co w 00 00 �q 0') ,It 04 CD 04 cli 04 Ll m m 5 0 w co cn 0� r z r co 24+00 3095 -r 3090 a".0 3075 24+00 25+00 25+00 26+00 26+00 27+00 PR HARDIN CREEK - SCALE: HOR 1 " = 30'; VERT 1 " = 3' 28+00 29 50 - 3095 3090 SANITARY SEWER LINE SUSPENDED OVER CHANNEL /_Zl_rvv 3085 mm 3075 29+50 NOTES: 1. CONTRACTOR TO IDENTIFY AND PROTECT EX. UTILITIES. ct 0 2. DISTURBANCE OF WETLANDS, TREES, AND/OR WOODY VEGETATION ED Z 0 SHALL BE KEPT TO MINIMUM EXTENT PRACTICAL TO COMPLETE WORK. 3. RESTORE ACCESS PATHS AND STORAGE AREA(S) TO ORIGINAL CONDITION UPON COMPLETION OF uj 0 THE PROJECT OR UPON SUCH TIME 0- AS DIRECTED BY THE PROJECT OWNER AND ENGINEER. 4. ON -SITE ROCK MATERIAL MAY BE REUSED FOR STRUCTURES, AT THE z co + DIRECTION OF THE ENGINEER. Z Z _j m N D u 0 z 5. CONSTRUCTED RIFFLE CAN BE Z F < 1­0 C) REPLACED WITH WOODY RIFFLE OR 0� 0 < (D 3: (D Z C) + ENHANCED HABITAT RIFFLE, AT THE �_ C/) D < �_ 0� APPROVAL OF THE ENGINEER. yj �- < 0 < 0� < F--- c/) �: - C) U) z 0 6. TOE WOOD TO EXTEND 10'INTO uj uj uj Z y uj C) DOWNSTREAM RIFFLE BANK. TOE 0 w 0� O� WOOD CAN BE REPLACED WITH z 0 00 w 0 0 u- ROCK TOE, AT THE APPROVAL OF 0 u- 0 z I_ 0 THE ENGINEER. < Z z Z �: < 7. FLOODPLAIN DEPRESSIONS TO NOT 0 EXCEED 18" BELOW BANKFULL ELEVATION. LOCATION SUBJECT TO CHANGE AT THE DIRECTION OF THE ENGINEER. 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 DATE: 1/22/2024 SCALE (34"X22"): 1 if = 30' SCALE (17"Xll"): 111=60' 0 30 60 SCALE IN FEET SHEET NUMBER 2.6 NOT TO SCALE — _/,/ / - -r -�- K� r1l C, rl co / 1"e tl —j LL 0 AV AV co r LENGTH OF BRIDGE TO BE r APPROXIMATELY 60'. ELEVATION 0 D Col( 0 DETERMINED. �g c� c\1 C) A C—� c\1 cu cu 0 FPT W F- 0 Z., /, 001� w TOB —J < C) w CC) �i co �q 0) It C14 C) C14 04 CN L, cu cu 2 0 w U) r z U) m � � 0§; 070 g - FIR 0+00 3095 �-- al m*e APPROXIMATE TRAIL ELEVA-r a "; (n Lo c� < r-- Lu co 0� CD 00 m w 11 0 > <w 0� _j (D�Lu LL 0 N, Z) MIAP \V11/\ *1115/-/� -9,1-- NOTES: 1. BRIDGE TYPE AND MANUFACTURER TO BE DETERMINED. Lu Lu 4u PR HARDIN CREEK. L41 SEE SHEET 2.6 Lu r tp- 0 PL 0 <- -- -------- 1+25--- +00 4t� THE GREENWAY TRAIL BRIDGE. J// LLJ 4`1 tl LLJ Lu Lu J- Lu -1- 14 LLJ Lu L 41j LLJ .40 Lu Lu o,� ,000,- bi 1+100 —j+p3095 co co y co Lu ry (D 0� r-- co CD m w —i w 3090 3085 :1ROXIMATE BRIDGE PIER LOCATIONS. RS TO SPAN BANKFULL CHANNEL 0 FOOTING DEPTH TO FOLLOW MANUFACTURERS SPECIFICATIONS. ! I ! I ! I ! I ! I ! I ! I ! co Z 0 co 0- 0 R 1 ! Lu U) LLJ W Q Lu 0 0� > CL w IL z Z Z -:] 0 D 0 �z 0 0� < c) < 0� < C) 0 (D C/) < Lu 0 < Z LL, z LLJ Z LLJ 0 1 0 z 13� co C) LL Z 0 < z < 0 ! I ! I ! I ! I ! I ! ! I ! I ! I ! I ! I ! (D z 0 12� Z C) 0 LU (D —j ct) Z 0 o Lu < LL a- 3: 1-- Z o Lu Lu z 12� (D Lu 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 DATE: 1/22/2024 SCALE (34"X22"): ill = 20' SCALE (1 7"X1 1 "): ill = 40' 0 20 40 SCALE IN FEET GREENWAY TRAIL CROSSING - SCALE: HOR 1 " = 20'; VERT 1 " = 2v SHEET NUMBER 2.7 PR HARDIN CREEK STA 0+00 VE: 2 3130 3125 3120 3115 3110 qlr)rl -60 -40 -20 0 20 40 60 80 10( PR HARDIN CREEK STA 3+00 VE: 2 3130 3125 3120 Lo 3115 3110 c\1 C) c\1 3105 c\1 04 Q1nn C7 -80 -60 -40 -20 0 20 40 60 80 100 12( cu 3130 3125 3120 3115 3110 3105 6 w F- PR HARDIN CREEK STA 6+00 VE: 2 0 3120 3115 3110 uj 3105 3100 inar, — F (D 1 -100 -80 -60 -40 -20 0 20 40 6C w co �q 0') It c\1 PR HARDIN CREEK STA 9+00 VE: 2 C) c\1 3120, 04 CN L, 3115 cu 3110 cu >1 3105 0 3100 w 3095 U) 3120 3115 3110 3105 3100 3095 3135 3130 3125 3120 3115 3110 3105 3100 -220 -200 -180 -160 -140 -120 -100 -80 -60 -40 -20 0 20 40 60 8C r PR HARDIN CREEK STA 12+00 VE: 2 1 Zu 01 10 3110 3105 3100 04 3095 -120 -100 -80 -60 -40 -20 0 20 40 6C 3120 3115 3110 3105 3100 3095 3090 PR HARDIN CREEK STA 15+00 VE: 2 3120 3115 3110 3105 3100 3095 3090 3085 120 -100 -80 -60 -40 -20 0 20 40 60 80 100 12( 3120 3115 3110 3105 3100 3095 3090 3085 PR HARDIN CREEK STA 1+50 VE: 2 3130 3125 3120 3115 3110 Qlr)rl 3130 3125 3120 3115 3110 3105 -100 -80 -60 -40 -20 0 20 40 60 80 10( PR HARDIN CREEK STA 4+50 VE: 2 3130 3125 3120 3115 3110 3105 q1nn1 -80 -60 -40 -20 0 20 40 6C PR HARDIN CREEK STA 7+50 VE: 2 3125 3120 3115 3110 3105 3100 Qnar, 15 1 ZZ) 3120 3120 3115 3115 3110 3110 3105 3105 3100 3100 3095 3095 3130 3125 3120 3115 3110 3105 3100 -160 -140 -120 -100 -80 -60 -40 -20 0 20 40 60 80 PR HARDIN CREEK STA 10+50 VE: 2 . . . . . ... . . . ... ... . . . .. ... . 3125 3120 3115 3110 3105 3100 3095 -200 -180 -160 -140 -120 -100 -80 -60 -40 -20 0 20 40 60 8C PR HARDIN CREEK STA 13+50 VE: 2 3115 3110 3105 3100 3095 3090 -120 -100 -80 -60 -40 -20 0 20 40 60 8C 3115 3110 3105 3100 3095 3090 3085 PR HARDIN CREEK STA 16+50 VE: 2 3115 3110 3105 3100 3095 3090 3085 140 -120 -100 -80 -60 -40 -20 0 20 40 60 80 100 12( 3115 3110 3105 3100 3095 3090 3085 3125 3120 3115 3110 3105 3100 3095 3090 SECTION LEGEND DESIGN SURFACE EXISTING GROUND 0 UJ U) W a- IL w z Z Z _j 0 D 0 0 0� z �z < c) < 0 0� < C) (D 0 (D 3: z co < Lu Lu < 0 < ryo 5; cf) 3: Z - o z z 0 LLJ W LLJ z LD C) LLJ 0 O� 1 0 LLJ Lu 0 z 13� co U) LL C) LL 0 I-- 0 Z z < C) < 0 r 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 DATE: 1/22/2024 SCALE (34"X22"): ill = 30' SCALE (1 7"X1 1 "): ill = 60' 0 30 60 SCALE IN FEET SHEET NUMBER 3.1 PR HARDIN CREEK STA 18+00 VE: 2 0I lu 3105 3100 3095 3090 3085 ,�npn -140 -120 -100 -80 -60 -40 -20 0 20 40 60 80 100 12( PR HARDIN CREEK STA 21+00 VE: 2 3105 3100 9 3095 3090 c\1 C) c\1 3085 04 CN 3080 -120 -100 -80 -60 -40 -20 0 20 40 60 80 100 12( cu PR HARDIN CREEK STA 24+00 VE: 2 3105 w F- 0 3100 3095 3090 uj 3085 3080 w qn7r, (D 1 -160 -140 -120 -100 -80 -60 -40 -20 0 20 40 60 8C w co �q 0') It PR HARDIN CREEK STA 27+00 VE: 2 c\1 C) 3095 c\1 04 CN 3090 L, cu 3085 cu 3080 0 3075 2 3105 3100 3095 3090 3085 3080 3105 3100 3095 3090 3085 3080 3075 3110 3105 3100 3095 3090 3085 3080 0 30701 1 1 1 1 w -140 -120 -100 -80 -60 -40 -20 0 20 40 60 80 100 120 14( U) r PR HARDIN CREEK STA 19+50 VE: 2 3105 3100 3095 3090 3085 ,�npn -100 -80 -60 -40 -20 0 20 40 60 80 100 12( PR HARDIN CREEK STA 22+50 VE: 2 3105 3100 3095 3090 3085 3080 ,�n7F, 3105 3100 3095 3090 3085 3080 -140 -120 -100 -80 -60 -40 -20 0 20 40 60 80 10( PR HARDIN CREEK STA 25+50 VE: 2 ,)UZJZ) 3090 3085 3080 3075 ,�n70 15 1 uu 3095 3095 3090 3090 3085 3085 3080 3080 3075 3075 11)70 '�070 3105 3100 3095 3090 3085 3080 3075 -140 -120 -100 -80 -60 -40 -20 0 20 40 60 80 100 12( PR HARDIN CREEK STA 28+50 VE: 2 -140 -120 -100 -80 -60 -40 -20 0 20 40 60 80 100 12( 3095 3090 3085 3080 3075 3070 3100 3095 3090 3085 3080 3075 3070 SECTION LEGEND DESIGN SURFACE EXISTING GROUND 0 UJ W 0 Q� a- IL w z Z Z _j 0 D 0 0 0� z �z < c) < 0 0� < C) (D 0 (D 3: z co < Lu Lu < 0 < 0� > cf) 3: Z - o z z 0 LLJ LLJ LLJ Z LD C) LLJ 0 O� 1 0 LLJ Lu 0 z 13� co U) LL C) LL 0 I-- 0 Z z < C) < 0 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 DATE: 1/22/2024 SCALE (34"X22"): ill = 30' SCALE (1 7"X1 1 "): ill = 60' 0 30 60 SCALE IN FEET SHEET NUMBER 3.2 C) C) 04 C) CN C4 CN -0 C uj U) w co 04 C) N 04 04 - cu 3 5 0 w U) C/) 0� r 0 w 0 75 w U) U) LIVE STAKES AND BAREROOT PLANTINGS PER RE -VEGETATION PLAN, DETAILS, AND SCHEDULES A OFFSET ROWS OF LIVE STAKES AND — BAREROOT PLANTINGS PER RE -VEGETATION PLAN AND DETAILS 0 TOE OF SLOPE 0 0 b cl� MIN. 8.0' u z < Z -J Lu U) UJ z — < Of fn < > z: ui �- ly- (D z U) UJ -j TIE TO EXISTING GRADE AT 10-1 INSTALL EROSION CONTROL MATTING ON ALL DISTURBED STREAM BANKS DETAILED PLAN NOT TO SCALE DETAILED PLAN NOT TO SCALE 9 INSTALL EROSION CONTROL MATTING OR LIVE TRANSPLANTS AS DIRECTED BY THE ENGINEER ON ALL DISTURBED STREAMBANKS. BLEND GRADING TO EXISTING GROUND AT 10-1 SLOPE (OR FLATTER) EXISTING 10-1 ----- GRADE PREPARE THE SOIL SURFACE BY LOW FLOW WSEL LOOSENING 2 - 4" OF SOIL. IF RIVER BANK MATERIAL IS NOT SUITABLE FOR RE -VEGETATION EXISTING � X CHANNEL AND PLANTING, INSTALL LIVE TRANSPLANTS AS DIRECTED BY THE ENGINEER ONSITE. GRADE EXISTING STREAMBANK FROM EXISTING LOW FLOW WATER SURFACE AT 3:1 DETAILED SECTION A - AV NOT TO SCALE STREAMBANK GRADING_ EROSION CONTROL MATTING I 10 10 121 :91111 -.121 V LTA I SECURE MATTING WITH 6" OVERLAP AND DOUBLED ECO-STAKES, OR A SINGULAR 2'LONG 2" x 2" WOOD STAKES WITH 3" GALVANIZED ROOFING NAIL AT THE TOP TO SECURE MATTING BANKFULLSTAGE /m/M/M/wm EXISTING GROUND ECO-STAKE MIN 12" LENGTH, OR 2'LONG 2" x 2" WOOD STAKES WITH 3" GALVANIZED ROOFING NAIL AT THE TOP TO SECURE MATTING. KEY IN MATTING WITH STAKES OR BY TUCKING UNDERNEATH RIFFLE SUBSTRATE. DETAILED SECTION A - AV NOT TO SCALE VERTICAL OVERLAP MIN. 6" WITH DOUBLE ECO-STAKES OR A SINGULAR 2'LONG 2" x 2" WOOD STAKES. EDGE OVERLAP MIN. 6" WITH DOUBLE ECO-STAKES AT 2'O.C. OR 2'LONG 2" x 2" WOOD STAKES. DETAILED STAKING PLAN NOT TO SCALE BANKFULLSTAGE EROSION CONTROL MATTING 3INGLE 12" ECO-STAKES DFFSET ROWS AT ?1_31 O.C. EROSION CONTROL MATTING STREAMBANK GRADING SPECIFICATIONS 1. ALL BANK GRADING WORK SHALL TAKE PLACE DURING DRY WORKING CONDITIONS. THE CONTRACT SHALL MINIMUZE THE EXPORT OF SEDIMENT TO ADJACENT SURFACE WATERS TO THE MAXIM EXTENT PRACTICABLE BY USING ADDITIONAL EROSION AND SEDIMENTATION CONTROL MEASURES NEEDED OR AS DIRECTED BY THE ENGINEER ONSITE. 2. FOR IMPLEMENTATION, THE CONTRACTOR SHALL GRADE THE RIVER BANK FROM THE EXISTING I OF SLOPE AT 3:1 TRANSITIONING TO A 10:1 SLOPE (OR FLATTER) TO THE ELEVATIONS AND GRAE MATCHING THE SURROUNDING AREA. ALL EXCAVATED MATERIAL SHALL BE HAULED AND PLACEE DESIGNATED AREAS ONSITE. 3. IF STREAMBANK MATERIAL IS NOT SUITABLE FOR PLANTING AND RE -VEGETATION, INSTALL L TRANSPLANTS AS DIRECTED BY THE ENGINEER ONSITE. 4. TRANSPLANTS AVAILABLE ONSITE MAY BE INSTALLED IN THE TOPSOIL AS DIRECTED BY THE ENGINE ONSITE. 5. THE SURFACE OF THIS FEATURE SHALL BE FINISHED TO A SMOOTH AND COMPACT SURFACE ACCORDANCE WITH THE LINES, GRADES, AND CROSS -SECTIONS OR ELEVATIONS SHOWN ON I DRAWINGS. 6. STABILIZATION OF THE WORK AREA WITH TEMPORARY AND PERMANENT SEEDING AND MULCHINC REQUIRED FOLLOWING GRADING OF THE STREAMBANK. INSTALL WOODY PLANTING AND VEGETAT AS SHOWN ON THE APPROVED RE -VEGETATION PLAN. EROSION CONTROL MATTING SPECIFICATIONS 1. EROSION CONTROL MATTING IS USED TO PROTECT RECENTLY CONSTRUCTED STREAM BANKS FF EROSION. THE MATTING WILL REMAIN INTACT WHILE THE BANK AND RIPARIAN VEGETATION MATUF PROVIDING CRITICAL BANK PROTECTION. 2. STREAM BANK EROSION CONTROL MATTING MATERIAL SPECIFICATIONS: 2.1. MACHINE DIRECTION TENSILE STRENGTH: 77 LB/IN 2.2. CROSS MATCH DIRECTION TENSILE STRENGTH: 86 LB/IN 2.3. APPARENT OPENING SIZE: 0.59" x 0.67" 2.4. PERCENT OPENING: 49% 2.5. MASS: 700 G/M2 3. BEFORE INSTALLING EROSION CONTROL MATTING, RAKE SOIL LEVEL, ADD TEMPORARY PERMANENT SEED, SOIL PREPARATION AND MULCH. 4. EROSION CONTROL MATTING SHALL BE PLACED ALONG THE LENGTH OF THE NEW CHANNEL FF THE TOE OF SLOPE AT THE INNER BERM TO THE BANKFULL STAGE. 5. SECURE MATTING IN PLACE BY STAKING AND OVERLAPPING AT THE SEEMS WITH A SHINGLE-T METHOD SUCH THAT THE OVERLAPPING PIECE IS IN THE SAME DIRECTION AS THE STREAM FLO\A SHOWN IN THE DETAIL. ADDITIONAL STAKING SHALL BE APPLIED BY THE CONTRACTOR AT ADDITIONAL COST IF THE MATTING SEPARATES FROM THE SOIL MORE THAN ONE INCH UNDE REASONABLE PULL. 6. EROSION CONTROL MATTING USED ON ALL STREAM BANKS SHALL BE MADE OF 100% NATURAL FIB AND MATERIALS AND BE BIODEGRADABLE UNDER NORMAL CLIMATE CONDITIONS. EROSION CONT MATTING CONTAINING PLASTICS OR PLASTIC BASED MATERIALS SHALL NOT BE USED. CL CL < OR z UM AS OE Z 0 IES co 0 g: IN UJ UJ W IVE (D ER Q 0 0� a- > IN 'H E a- < ; Is ON z ZZ I 0 D 0 �z 0 0� z 0 < c) < 0� < 0 (D cf) 0 (D 3: z C/) < 0� Lu 0 < Lu cf) < �: Z Z w - Lu 2 0 LLJ 0� Z 0 < W c) 0� 0 LLJ w 0 LL] 0� 0 z 13� 00 n c/) LL C) LL I­ K 0 0 < C) Z z < 0 IOM )ES, Jennings \ND Environmental IOM 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 YPE AS NO R A E R S ROL DATE: 1/22/2024 NOT TO SCALE SHEET NUMBER 4.1 (o 0 c\l C) 04 cq 04 c: cu uj 0 w cf) C114 C) 04 04 w U) U) w r < w < w U) U) EXTEND RIFFLE SUBSTRATEINTO GLIDE MIN. Y3 WBKF P.T. STATION PER PLAN EXTEND RIFFLE MATERIAL INTO GLIDE MIN. 13 WBKF P.T. STATION PER PLAN MICROPOOL RIFFLE LENGTH VARIES PER PLAN EXTEND RIFFLE SUBSTRATEINTO RUN MIN. Y3 WBKF P.T. ELEVATION PER PROFILE GLIDE BANKFULL RIFFLE SLOPE VARIE //7 RIFFLE MATERIAL PER NOTES P.C. ELEVATION PER PROFILE RUN STREAMBED CONSTRUCTED RIFFLE SPECIFICATIONS 1 RIFFLES SHALL BE CONSTRUCTED OF NATIVE GRAVEL AND COBBLE MATERIAL AVAILABLE ON�C THE ENGINEER MUST APPROVE THE USE OF ALL ONSITE NATIVE MATERIAL. WHEN NA SUBSTRATE IS NOT SUFFICIENT FOR COMPLETION OF THE STRUCTURE, QUARRIED STONE SHAL USED TO SUPPLEMENT THE RIFFLE MATERIAL ACCORDING TO THE RIFFLE SUBSTR SPECIFICATIONS. 2. FOR INSTALLATION, THE CONTRACTOR SHALL OVER EXCAVATE THE LENGTH OF THE RIF BACKFILL WITH NATIVE GRAVEL AND COBBLE MATERIAL TO THE ELEVATIONS SHOWN ON PROPOSED PROFILE. 3. CONSTRUCTED RIFFLE MATERIAL SHALL EXTEND A MINIMUM OF 10.0 FT U/S OF THE P.T. INTO GLIDE AND A MINIMUM OF 10.0 FT D/S OF THE P.C. INTO THE RUN. 4. THE RIFFLE MATERIAL SHALL BE PLACED AT A UNIFORM THICKNESS SUCH THAT, IN CROSS -SECT ITS LOWEST ELEVATION OCCURS IN THE CENTER OF THE CHANNEL. 5. FINE WOODY MATERIAL MAY BE INTEGRATED INTO THE RIFFLE MATERIAL TO ENHANCE F DIVERSITY AND HYPORHEIC EXCHANGE. DETAILED SECTION A A' 6. RIFFLE MATERIAL SHALL BE COMPACTED USING AN EXCAVATOR BUCKET SUCH THAT FUT Z K NOT TO SCALE SETTLEMENT OF THE MATERIAL IS KEPT TO A MINIMUM. �A' 7. THE SURFACE OF THIS STRUCTURE SHALL BE FINISHED TO A SMOOTH AND COMPACT SURFAC :D)SR) ACCORDANCE WITH THE LINES, GRADES, AND CROSS -SECTIONS OR ELEVATIONS SHOWN ON FLOW - - <tin P.C. STATION EROSION CONTROL MATTING DRAWINGS. THE DEGREE OF FINISH FOR INVERT ELEVATIONS SHALL BE WITHIN 0.1 FT OF BANKFULL PER PLAN GRADES AND ELEVATIONS INDICATED. STREAMBANK 8. RE -DRESSING OF CHANNEL AND BANKFULL BENCH/FLOODPLAIN WILL LIKELY BE REQUI FOLLOWING INSTALLATION OF IN -STREAM STRUCTURES AND SHALL BE CONSIDERED INCIDENTA TOE OF SLOPE CONSTRUCTION. BANKFULL 9. SEE TYPICAL RIFFLE CROSS SECTION FOR DIMENSIONS. STAGE 5. SUPPLEMENTAL RIFFLE MATERIAL SPECIFICATIONS: KEY MATTING INTO 0 NCDOT CLASS 1 - 70% RIFFLE TRENCH RIFFLE MATERIAL 0 NCDOT CLASS B - 30% MIN. 2.0' RIFFLE MATERIAL PER NOTES DETAILED PLAN NOT TO SCALE I LTI-11 :4 co BANKFULL STAGE DETAILED PLAN NOT TO SCALE W-11 EM, TWA nl� LIF 41111 P.T. ELEVATION PER PROFILE GLIDE DETAILED SECTION B - B' NOT TO SCALE CONSTRUCTED RIFFLE BANKFULL MICROPOOL RIFFLE SLOPE VARIES PER PROFILE WOODY MATERIAL AND BRUSH WORKED INTO RIFFLE MATERIAL RII I L-E MATERIAL 1" 6" PROTRUSION DETAILED SECTION A A NOT TO SCALE EROSION CONTROL MATTING 8. THE SURFACE OF THIS STRUCTURE SHALL BE FINISHED TO A COMPACT SURFACE IN ACCORDA 1" - 6" ABOVE RIFFLE MATERIAL WITH THE LINES, GRADES, AND CROSS -SECTIONS OR ELEVATIONS SHOWN ON THE DRAWINGS. LOGS/WOODY DEBRIS BANKFULL DEGREE OF FINISH FOR INVERT ELEVATIONS SHALL BE WITHIN 0.1 FT OF THE GRADES ELEVATIONS INDICATED. /X/// KEY MATTING INTO RIFFLE TRENCH RIFFLE MATERIAL RIFFLE COBBLE/BOULDER MATERIAL MIN. 2.0' PER NOTES P.C. ELEVATION PER PROFILE RUN ENHANCED HABITAT RIFFLE SPECIFICATIONS 1. FOR INSTALLATION, THE CONTRACTOR SHALL OVER EXCAVATE THE LENGTH OF THE RIFFLE BACKFILL THE TRENCH WITH THE SPECIFIED RIFFLE SUBSTRATE MATERIAL TO THE ELEVATI SHOWN ON THE PROPOSED PROFILE. 2. RIFFLE MATERIAL SHALL EXTEND A MINIMUM OF 13 WBKF U/S OF THE P.T. INTO THE GLIDE AND A MINI OF 13 WBKF D/S OF THE P.C. INTO THE RUN. 3. ENHANCED HABITAT RIFFLES SHALL BE BACKFILLED WITH RIFFLE MATERIAL CONSISTING QUARRIED STONE. RIFFLE MATERIAL SHALL BE COMPACTED USING AN EXCAVATOR BUCKET S THAT FUTURE SETTLEMENT OF THE MATERIAL IS KEPT TO A MINIMUM. 4. ENHANCED HABITAT RIFFLE MATERIAL SPECIFICATIONS- * NCDOT CLASS 1 70% 0 NCDOT CLASS B 30% 6. RIFFLE MATERIAL SHALL CONSIST OF LARGE LOGS, BRUSH, AND BOULDERS EMBEDDED IN COB AND GRAVEL SUBSTRATE IN A DISORGANIZED MANNER, WITHIN THE STREAM CHANNEL. THE LO AND ROCKS CREATE SMALL IRREGULAR DROPS, POOLS, AND TURBULENT FLOW 7. WOODY MATERIAL 3" - 9" IN SIZE SHALL BE INTEGRATED INTO THE RIFFLE SUBSTRATE TO ENHA FLOW DIVERSITY AND HYPORHEIC EXCHANGE. WOODY MATERIAL SHALL PROTRUDE 11, - 61, ABOVE FINISHED RIFFLE SUBSTRATE. LOGS SHALL BE ANCHORED WITH PLACEMENT OF OTHER LOGS, RO OR BY HAVING 1/3 OF THEIR LENGTH BURIED IN THE CHANNEL BOTTOM OR BANKS. DETAILED SECTION B - B' NOT TO SCALE ENHANCED HABITAT RIFFLE 9. RE -DRESSING OF CHANNEL AND BANKFULL BENCH/FLOODPLAIN WILL LIKELY BE REQUI FOLLOWING INSTALLATION OF IN -STREAM STRUCTURES AND SHALL BE CONSIDERED INCIDENTAL CONSTRUCTION. 10.THE END OF RIFFLE CONTROL POINT MAY TIE INTO OTHER IN -STREAM STRUCTURE (E.G. J-HO VANE, LOG STEP, ETC.) ,ITE. z IVE BE ATE Z FLE co 0 0 0- THE ui LLJ V) W THE (D ION, Q ui > 0 OW 0� a. > w i JRE E IN THE THE < z RED 0 0 TO z 0 < c) 0 U) 3: Z < yj < 0 ui < Z cl) z �: - 0 UJ ui z < o UJ LLJ 0 LU 0 Lu 0 LI lcl� �— 0 z 13� co n co LL C) LL 0 0 < C) Z z < 0 AND ONS mM OF UCH MAIMAlteill"r4al 7 SAMUEL ASHE DRIVE BLE ASHEVILLE, NC 28805 GS NCE THE KS, NCE THE AND RED TO OK DATE: 1/22/2024 NOT TO SCALE SHEET NUMBER 4.2 .4 2 WOODY RIFFLE SPECIFICATIONS � 0 NE, C) C) 04 C) 04 04 N Ll m D c m m _0 LLJ F- 0 uj U) w cr) 0') 'IT 04 C) N 04 04 - cu 3 5 0 w U) c/) 0� r w 0 75 w U) co EXTEND RIFFLE MATERIAL INTO GLIDE MIN. 13 WBKF P.T. STATION PER PLAN GRAVEL BACKFILL UPSTREAM OF STRUCTURE NON -WOVEN FILTER FABRIC HIGH DENSITY N 0 PLANTINGS 0 -�o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 BANKFULL Ali a RIFFLE LENGTH VARIES PER PLAN 9 V Nil MA I 1mvil 04 1 BANKFULLSTAGE DETAILED PLAN NOT TO SCALE SCOUR POOL BANKFULL P.T. ELEVATION PER PROFILE RIFFLE SLOPE VARIES PER PROFILE P.C. ELEVATION GLIDE PER PROFILE RUN 3" - 6" WOODY MATERIAL AND BRUSH WORKED INTO RIFFLE MATERIAL 1" - 3" PROTRUSION STREAMBED RIFFLE MATERIAL EXTEND RIFFLE MATERIAL INTO RUN MIN. 3' WBKF DETAILED SECTION A - AV NOT TO SCALE A' -P.C. STATION PER PLAN EROSION CONTROL MATTING 1 - 3" ABOVE RIFFLE MATERIAL BANKFULL KEY MATTING INTO RIFFLE TRENCH RIFFLE MATERIAL_ RIFFLE MATERIAL MIN. 2.0' PER NOTES DETAILED SECTION B - 13' NOT TO SCALE WOODY RIFFLE BANKFULL--\ HEADER BOULDER 1 FT OFFSET SCOUR POOL GRAVEL BACKFILL BELOW STRUCTURE MATERIAL NON -WO EN FILTER FAE EXTEND VANE ARM 3RIC INTO STREAMBANK MIN. 1 O.O'OR THREE 0 0 FULL BOULDER FOOT R 0 LENGTHS BOULDER IN '0 T M IN 1 0 F UL� B LENGT ;o 0 0 OOL 0 0 0 81 DETAILED SECTION A - A' 0 0 NOT TO SCALE 0 0 0 0 KEY BOULDERS INTO 0 0 STREAMBANK @ 1 To 2 BKFSTAGE 2 3 P.C. ELEVATION PER PROFILE SLOPE 3%, KEY BOULDERS INTO FIT BOULDERS TIGHTLY TOGETHER STREAMBANK MIN. 15 FT OR PLACE BOULDERS INTO STREAMBED A THREE FULL BOULDER LENGTHS MINIMUM OF THE BOULDER DIAMETER DETAILED SECTION B - 13' NOT TO SCALE 1. FOR INSTALLATION, THE CONTRACTOR SHALL OVER EXCAVATE THE LENGTH OF THE RIFFLE AND z 3: BACKFILL THE TRENCH WITH THE SPECIFIED RIFFLE SUBSTRATE MATERIAL TO THE ELEVATIONS < ct SHOWN ON THE PROPOSED PROFILE. 0 2. RIFFLE MATERIAL SHALL EXTEND A MINIMUM OF 13 WBKF U/S OF THE P.T. INTO THE GLIDE AND A MINIMUM co Z OF 13 WBKF D/S OF THE P.C. INTO THE RUN. co 0 0 ui g: 3. THE RIFFLE MATERIAL SHALL BE PLACED AT A UNIFORM THICKNESS SUCH THAT, IN CROSS-SECTION, ITS LOWEST ELEVATION OCCURS IN THE CENTER OF THE CHANNEL. UJ 4. WOODY RIFFLES SHALL BE BACKFILLED WITH RIFFLE MATERIAL CONSISTING OF QUARRIED STONE. RIFFLE MATERIAL SHALL BE PLACED AT A UNIFORM THICKNESS SUCH THAT, IN CROSS-SECTION, ITS (D LOWEST ELEVATION OCCURS IN THE CENTER OF THE CHANNEL. RIFFLE MATERIAL SHALL BE COMPACTED USING AN EXCAVATOR BUCKET SUCH THAT FUTURE SETTLEMENT OF THE MATERIAL IS Q KEPT TO A MINIMUM. > 0 5. CONSTRUCTED RIFFLE MATERIAL SPECIFICATIONS: • NCDOT CLASS 1 - 70% < • NCDOT CLASS B - 30% 6. WOODY MATERIAL 3" - 6" IN SIZE SHALL BE INTEGRATED INTO THE RIFFLE SUBSTRATE TO ENHANCE FLOW DIVERSITY AND HYPORHEIC EXCHANGE. WOODY MATERIAL SHALL PROTRUDE 11, - 31, ABOVE THE FINISHED RIFFLE SUBSTRATE. 7. RIFFLE MATERIAL SHALL BE COMPACTED USING AN EXCAVATOR BUCKET SUCH THE DEEPEST POINT OF THE CHANNEL IS ALONG THE CENTERLINE AND THAT FUTURE SETTLEMENT OF THE MATERIAL IS z KEPT TO A MINIMUM. Z Z _j 0 D 0 8. THE SURFACE OF THIS STRUCTURE SHALL BE FINISHED TO A SMOOTH AND COMPACT SURFACE IN 0 ACCORDANCE WITH THE LINES, GRADES, AND CROSS -SECTIONS OR ELEVATIONS SHOWN ON THE < c) DRAWINGS. THE DEGREE OF FINISH FOR INVERT ELEVATIONS SHALL BE WITHIN 0.1 FT OF THE [)� < 0 GRADES AND ELEVATIONS INDICATED. 0 (D 9. RE -DRESSING OF CHANNEL AND BANKFULL BENCH/FLOODPLAIN WILL LIKELY BE REQUIRED < FOLLOWING INSTALLATION OF IN -STREAM STRUCTURES AND SHALL BE CONSIDERED INCIDENTAL TO Lu 0 CONSTRUCTION. < Z LLJ W LLJ Z LLJ 0 1 0 z 13� co C) LL 0 K < C) Z < 0 BOULDER J-HOOK SPECIFICATIONS 1. ALL BOULDERS USED FOR THE PROPOSED STRUCTURE SHALL BE STRUCTURAL STONE, CUBICAL OR RECTANGULAR IN SHAPE. THE ENGINEER MUST APPROVE THE USE OF BOULDERS THAT MAY BE AVAILABLE ONSITE. BOULDERS SHALL BE 3.0'X 5.0'X 2.5'(W X L X H) +/- 0.5'. THE MINIMUM ACCEPTABLE BOULDER THICKNESS (H) IS 2.0'. BOULDERS LONGER (L) THAN 5.5'WILL BE ACCEPTED. 2. DIMENSIONS AND SLOPES OF STRUCTURES DESCRIBED IN THE DETAIL MAY BE ADJUSTED BY DESIGN ENGINEER TO FIT CONDITIONS ONSITE. CONTRACTOR WILL BE REQUIRED TO FIT BOULDERS TOGETHER TIGHTLY. 3. GAPS BETWEEN BOULDERS SHALL BE MINIMIZED BY FITTING BOULDERS TOGETHER AND PLUGGING WITH NC DOT CLASS A ROCK OR CHINKING STONE APPROVED BY ENGINEER. 2. HEADER BOULDERS SHALL BE UNDERLAIN BY FOOTER BOULDERS TO PROVIDE A FOUNDATION UNLESS OTHERWISE DIRECTED BY THE ENGINEER. HEADER BOULDERS SHALL BE OFFSET 1.0 FT UPSTREAM OF THE FOOTER. 3. SET BOULDER INVERTS AT ELEVATION SHOWN ON THE PLAN AND PROFILE SHEETS. NO ELEVATIONS OF THE BOULDERS MAY VARY FROM THE PLAN SHEETS WITHOUT DIRECTION FROM THE ENGINEER. 4. NON -WOVEN GEOTEXTILE SHALL BE PLACED ON THE UPSTREAM SIDE OF THE STRUCTURE TO PREVENT WASHOUT OF SEDIMENT THROUGH BOULDER GAPS. FILTER FABRIC SHALL EXTEND FROM THE BOTTOM OF THE FOOTER BOULDER TO THE FINISHED GRADE ELEVATION AND SHALL BE PLACED THE ENTIRE LENGTH OF THE STRUCTURE. SELECT BACK FILL MATERIAL SHALL BE PLACED UPSTREAM OF THE GEOTEXTILE MATERIAL. 5. GRAVEL MATERIAL CONSISTING OF A WELL -GRADED BLEND OF NCDOT CLASS A RIPRAP AND ASTM #57 ROCK MIXED WITH EARTH SHALL BE USED TO BACKFILL THE STRUCTURE. BACKFILL MATERIAL SHALL BE COMPACTED SUCH THAT FUTURE SETTLEMENT OF THE MATERIAL IS KEPT TO A MINIMUM. 6. THE SURFACE OF THIS STRUCTURE SHALL BE FINISHED TO A SMOOTH AND COMPACT SURFACE IN ACCORDANCE WITH THE LINES, GRADES, AND CROSS -SECTIONS OR ELEVATIONS SHOWN ON THE DRAWINGS. THE DEGREE OF FINISH FOR INVERT ELEVATIONS SHALL BE WITHIN 0.1 FT OF THE GRADES AND ELEVATIONS INDICATED. 7. RE -DRESSING OF CHANNEL AND BANKFULL BENCH/FLOODPLAIN WILL LIKELY BE REQUIRED FOLLOWING INSTALLATION OF IN -STREAM STRUCTURES AND SHALL BE CONSIDERED INCIDENTAL TO CONSTRUCTION. z 0 (D cf) Z Lu cl) Z 2 0 < c) LU o� 0� 0 Lu n co LL I­ 0 z 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 DATE: 1/22/2024 NOT TO SCALE DETAILED PLAN NOT TO SCALE BOULDER J-HOOK SHEET NUMBER 4.3 �-5; 04 C.0 �i 1p C) 04 C) CN C4 CN Ll m D C m m _0 C 0 C) uj 0 U) 0 w cr) N C) 04 c\f 04 - cu 3 5 0 w U) W 0� r CD w 0 75 w U) U) BURY LOGS INTO STREAMBED MIN. 5.0'AND ANCHOR IN PLACE WITH BOULDERS U/S AND D/S. 15-200 GRAVELAND COBBLE BACKFILL BEHIND LOG LAI 0 HIGH DENSITY 0 PLANTING 0 0 0 0 0 09/Vil'J, ANCHORLOGS 0 IN -PLACE WITH ROOT WAD 0 0 0 EXTEND VANE ARM INTO STREAMBANK 0 MIN. 5.0' CIO -rf-% DUMT LUkJO IN STREAMBED MIN. E SELECT BACK BEHIND STRUCT HIGH DENSITY - PLANTING EXTEND VANE ARM INTO STREAMBANK MIN. 5.0' N ANCHOR LOGS IN -PLACE WITH BOULDERS U/S AND D/S m 0 0 DETAILED PLAN NOT TO SCALE Wa DETAILED PLAN NOT TO SCALE BANKFULL HEADER LOG 0 i u- SCOUR POOL GRAVEL AND COBBLE BELOW BACKFILL MATERIAL STRUCTURE ;o NON -WOVEN FILTER FABRIC BACKER LOG - SCOUR DETAILED SECTION A - Av POOL NOT TO SCALE ROOT BALL VANE ARM INTO STREAM BANK @ Y2 TO 3/3 BKF STAGE ARM SLOPE 2% / 17, BANKFULL FOOTER ANCHOR LOG BOULDER DETAILED SECTION B - B' NOT TO SCALE LOG VANE_ BANKFULL --\\, HEADER LOG �ERS TIGHTLY SCOUR POOL GRAVEL AND COBBLE R BELOW STRUCTURE BACKFILL MATERIAL 3OULDER SILL EAMBANK MIN 'HREE FULL (3) NON -WOVEN 77/ 'LENGTHS FILTER FABRIC /7/77/ BACKER LOG DETAILED SECTION A - A' NOT TO SCALE ISITY I D VANE ARM INTO STREAM BANK @ Y2 TO BKF STAGE HEADER BOULDER ARM SLOPE 21/o (SILL) JLL LOG LENGTH VARIES. SEE NOTE 1 FOOTER BOULDER (SILL) DETAILED SECTION B - Bw NOT TO SCALE LOG J-HOOK VANE LOG VANE (LV) SPECIFICATIONS CL CL i i i i i i i < 1 ALL LOGS SHALL BE RELATIVELY STRAIGHT AND LIMBS AND BRANCHES SHALL BE TRIMMED FLUSH. z 3: LOGS SHALL HAVE MINIMUM DIAMETER OF 1.5'. HEADER LOGS SHALL BE UNDERLAIN BY FOOTER LOGS < ct TO PROVIDE A SILL UNLESS OTHERWISE DIRECTED BY THE ENGINEER. HEADER LOGS SHALL BE OFFSET SLIGHTLY DOWNSTREAM OF THE FOOTER THE HEADER LOG OF THE VANE ARE SHALL TIE INTO THE STREAMBANK AT Y2 TO % BANKFULL STAGE. THE LOG VANE ARM SHALL EXTEND INTO THE co Z OUTSIDE STREAMBANK AND STREAMBED A MINIMUM OF 10.0 FT ON EACH END. ALL GAPS/VOIDS LARGER THAN 1 INCHES BETWEEN THE HEADER AND FOOTER LOGS SHALL BE CHINKED WITH LIMBS co 0 AND/OR BRUSH ON THE UPSTREAM SIDE PRIOR TO PLACEMENT OF THE GEOTEXTILE. UJ UJ 2. ALL BOULDERS USED FOR THE STRUCTURE SHALL BE STRUCTURAL STONE, CUBICAL OR RECTANGULAR IN SHAPE. THE ENGINEER MUST APPROVE THE USE OF BOULDERS THAT MAY BE AVAILABLE ONSITE. BOULDERS DIMENSIONS SHALL BE 3.0' X 5.0' X 2.0' (W X L X H) ± 0.5 FT. THE MINIMUM ACCEPTABLE BOULDER THICKNESS (H) IS 1.5'. BOULDERS LONGER (L) THAN 5.5' WILL BE (D ACCEPTED. GAPS BETWEEN BOULDERS SHALL BE MINIMIZED BY FITTING BOULDERS TOGETHER AND m PLUGGING WITH NC DOT CLASS A ROCK OR CHINKING STONE APPROVED BY ENGINEER. HEADER Q BOULDERS SHALL BE UNDERLAIN BY FOOTER BOULDERS TO PROVIDE A FOUNDATION UNLESS 0 OTHERWISE DIRECTED BY THE ENGINEER. HEADER BOULDERS SHALL BE OFFSET 1.0 FT UPSTREAM OF 6� a- THE FOOTER. a - < 3. SET BOULDER INVERTS AT ELEVATION SHOWN ON THE PLAN AND PROFILE SHEETS. NO ELEVATIONS OF THE BOULDERS MAY VARY FROM THE PLAN SHEETS WITHOUT DIRECTION FROM THE ENGINEER. 4. ON THE UPSTREAM SIDE OF THE STRUCTURE A LAYER OF NON -WOVEN GEOTEXTILE FABRIC SHALL BE PLACED AS SHOWN IN THE DETAIL ALONG THE ENTIRE LENGTH OF THE LOG VANE AND BOULDER J-HOOK. SECURE ALL GEOTEXTILE FABRIC ON TOP OF FOOTER LOG USING 3 INCH 10D GALVANIZED COMMON NAIL ON 12 IN SPACING ALONG LOG. NAIL NON -WOVEN GEOTEXTILE TO EDGE OF HEADER z LOG AND BACKFILL. Z Z _j D 0 5. GRAVEL MATERIAL CONSISTING OF A WELL -GRADED BLEND OF NCDOT CLASS A RIP -RAP AND ASTM 0 z #57 ROCK MIXED WITH EARTH SHALL BE USED TO BACKFILL THE STRUCTURE. BACKFILL MATERIAL < c) 0 SHALL BE COMPACTED SUCH THAT FUTURE SETTLEMENT OF THE MATERIAL IS KEPT TO A MINIMUM. [)� < 0 (D 0 0 3: z 6. PLACE BOULDERS UPSTREAM AND DOWNSTREAM OF THE LOG VANE ARM IN THE STREAMBANK. THE D FINISHED ELEVATION OF THE BOULDERS SHALL BE BELOW THE FINISHED GRADE OF THE ADJACENT u) < jl� �: < FLOODPLAIN AND SHALL NOT PROTRUDE OUT OF THE STREAMBANK. yj 0 < ui < Z GO 7. DIMENSIONS AND SLOPES OF STRUCTURES DESCRIBED IN THE DETAIL MAY BE ADJUSTED BY DESIGN �: z ENGINEER TO FIT CONDITIONS ONSITE. �e - LLJ 0 LIJ z < c) 8. THE SURFACE OF THIS STRUCTURE SHALL BE FINISHED TO A SMOOTH AND COMPACT SURFACE IN UJ 0� 0 uj o� ACCORDANCE WITH THE LINES, GRADES, AND CROSS -SECTIONS OR ELEVATIONS SHOWN ON THE 0 UJ 0 0 DRAWINGS. THE DEGREE OF FINISH FOR INVERT ELEVATIONS SHALL BE WITHIN 0.1 FT OF THE GRADES Lij (]� co uj LL AND ELEVATIONS INDICATED. z C) LL I­ 9. RE -DRESSING OF CHANNEL AND BANKFULL BENCH/FLOODPLAIN WILL LIKELY BE REQUIRED Fn O� Z 0 0 FOLLOWING INSTALLATION OF IN -STREAM STRUCTURES AND SHALL BE CONSIDERED INCIDENTAL TO < z z CONSTRUCTION. 3: < 0 LOG J-HOOK VANE SPECIFICATIONS 1 ALL LOGS SHALL BE RELATIVELY STRAIGHT AND LIMBS AND BRANCHES SHALL BE TRIMMED FLUSH. LOGS SHALL HAVE MINIMUM DIAMETER OF 1.5'. VANE LENGTH SHALL BE AS FOLLOWS- ASHWORTH CREEK - 40 FEET, UT1 - 15 FEET. HEADER LOGS SHALL BE UNDERLAIN BY FOOTER LOGS TO PROVIDE A SILL UNLESS OTHERWISE DIRECTED BY THE ENGINEER. HEADER LOGS SHALL BE OFFSET SLIGHTLY DOWNSTREAM OF THE FOOTER LOG. THE HEADER LOG OF THE VANE ARE SHALL TIE INTO THE STREAMBANK AT Y2 TO �/3 BANKFULL STAGE. THE LOG VANE ARM SHALL EXTEND INTO THE OUTSIDE STREAMBANK AND STREAMBED A MINIMUM OF 5.0 FT ON EACH END. ALL GAPS/VOIDS LARGER THAN 1 INCHES BETWEEN THE HEADER AND FOOTER LOGS SHALL BE CHINKED WITH LIMBS AND/OR BRUSH ON THE UPSTREAM SIDE PRIOR TO PLACEMENT OF THE GEOTEXTILE. 2. ALL BOULDERS USED FOR THE STRUCTURE SHALL BE STRUCTURAL STONE, CUBICAL OR RECTANGULAR IN SHAPE. THE ENGINEER MUST APPROVE THE USE OF BOULDERS THAT MAY BE AVAILABLE ONSITE. BOULDERS SHALL BE 3.0' X 5.0' X 2.5' (W X L X H) +/- 0.5'. THE MINIMUM ACCEPTABLE BOULDER THICKNESS (H) IS 2.0'. BOULDERS LONGER (L) THAN 55WILL BE ACCEPTED. GAPS BETWEEN BOULDERS SHALL BE MINIMIZED BY FITTING BOULDERS TOGETHER AND PLUGGING WITH NC DOT CLASS A ROCK OR CHINKING STONE APPROVED BY ENGINEER. HEADER BOULDERS SHALL BE UNDERLAIN BY FOOTER BOULDERS TO PROVIDE A FOUNDATION UNLESS OTHERWISE DIRECTED BY THE ENGINEER. HEADER BOULDERS SHALL BE OFFSET 1.0 FT UPSTREAM OF THE FOOTER. 3. SET BOULDER INVERTS AT ELEVATION SHOWN ON THE PLAN AND PROFILE SHEETS. NO ELEVATIONS OF THE BOULDERS MAY VARY FROM THE PLAN SHEETS WITHOUT DIRECTION FROM THE ENGINEER. 4. ON THE UPSTREAM SIDE OF THE STRUCTURE A LAYER OF NON -WOVEN GEOTEXTILE FABRIC SHALL BE PLACED AS SHOWN IN THE DETAIL ALONG THE ENTIRE LENGTH OF THE LOG VANE AND BOULDER J-HOOK. SECURE ALL GEOTEXTILE FABRIC ON TOP OF FOOTER LOG USING 3 INCH 10D GALVANIZED COMMON NAIL ON 12 IN SPACING ALONG LOG. NAIL NON -WOVEN GEOTEXTILE TO EDGE OF HEADER LOG AND BACKFILL. 5. GRAVEL MATERIAL CONSISTING OF A WELL -GRADED BLEND OF SURGE STONE AND ASTM #57 ROCK MIXED WITH EARTH SHALL BE USED TO BACKFILL THE STRUCTURE. BACKFILL MATERIAL SHALL BE COMPACTED SUCH THAT FUTURE SETTLEMENT OF THE MATERIAL IS KEPT TO A MINIMUM. 6. PLACE BOULDERS UPSTREAM AND DOWNSTREAM OF THE LOG VANE ARM IN THE STREAMBANK. THE FINISHED ELEVATION OF THE BOULDERS SHALL BE BELOW THE FINISHED GRADE OF THE ADJACENT FLOODPLAIN AND SHALL NOT PROTRUDE OUT OF THE STREAMBANK. 7. DIMENSIONS AND SLOPES OF STRUCTURES DESCRIBED IN THE DETAIL MAY BE ADJUSTED BY DESIGN ENGINEER TO FIT CONDITIONS ONSITE. 8. THE SURFACE OF THIS STRUCTURE SHALL BE FINISHED TO A SMOOTH AND COMPACT SURFACE IN ACCORDANCE WITH THE LINES, GRADES, AND CROSS -SECTIONS OR ELEVATIONS SHOWN ON THE DRAWINGS. THE DEGREE OF FINISH FOR INVERT ELEVATIONS SHALL BE WITHIN 0.1 FT OF THE GRADES AND ELEVATIONS INDICATED. 9. RE -DRESSING OF CHANNEL AND BANKFULL BENCH/FLOODPLAIN WILL LIKELY BE REQUIRED FOLLOWING INSTALLATION OF IN -STREAM STRUCTURES AND SHALL BE CONSIDERED INCIDENTAL TO CONSTRUCTION. 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 DATE: 1/22/2024 NOT TO SCALE SHEET NUMBER 4.4 < �? 1p C) ,It 04 C) CN C4 CN D C m m _0 0 co < co Lp 0) ,It N C) 04 cq N m w U) CD w 0 2 < w U) U) SOIL GEOLIFTS TO BANKFULLSTAGE Zi 0 ) 0 Cj DETAILED PLAN NOT TO SCALE 1 lllr7 Cl-rAl,r7C' Akir-% MA 'RE < 0 LIVE CUTTINGS 7- INSTALLED BETWEEN LIFTS 2.0'O.C. DETAILED PLAN NOT TO SCALE EXCAVATION LIMITS WOOD STAKE 2" X 2" X 18" - 36" COMPACTED BACKFILL WOODY MATERIAL INSTALLED IN 1.0' LIFTS /WIDTH OF WOODY MATERIAL, Y3 WBKF OR GREATER DETAILED SECTION A A' NOT TO SCALE LIVE STAKES AND BARE ROOT PLANTINGS BANKFULL STAGE SOIL LIFTS SHALL USE TWO LAYERS OF BIODEGRADABLE MATTING: 700 G/M2 COIR 2 MATTING (OUTER) AND 320 G/M EROSION CONTROL BLANKET (INNER). LIVE CUTTINGS UNCONSOLIDATED GRAVEL AND TOPSOIL TOP OF WOODY MATERIAL = +05 ABOVE DOWNSTREAM PT ELEV. APPROXIMATE DOWNSTREAM PT ELEV. STREAMBED AT MAX POOL DEPTH TOE WOOD PROTECTION WITH SOIL LIFT - EXCAVATION LIMITS WOOD STAKE 2" X 2" X 18" - 36" COMPACTED BACKFILL NCDOT CLASS B RIPRAP INSTALLED IN 1.0'LIFTS LIVE STAKES AND BARE ROOT PLANTINGS BANKFULL STAGE I NAM if Mvm�� 11 — . — 0 &VAMMAMAVAMAVAN 0 I VLAVATJ RAMAVAVAMAVA RAVAMAVAMAVAMAVAM Ilk I L / A A TOPSOIL -0, Q Q TOP OF ROCK +05ABOVE 00- DOWNSTREAM PT ELV. '7"APPROXIMATE DOWNSTREAM PT ELV 0 CC) 77-7 7 7 7 / / / / ' / / / /, 'A /WIDTH OF RIPRAP MATERIAL STREAMBED AT 13 WBKF OR GREATER MAX POOL DEPTH DETAILED SECTION A A' NOT TO SCALE ROCK TOE PROTECTION WITH SOIL LIFT TOE WOOD PROTECTION WITH SOIL LIFT SPECIFICATIONS 1. WOODY MATERIAL USED IN THE BRUSH TOE SHALL CONSIST OF LOGS, LARGE BRANCHES AND WOOD DEBRIS RANGING IN DIAMETER FROM 1" TO 12". LARGE VOIDS SHALL BE FILLED WITH FINE WOOD MATERIAL AND DEBRIS. ALL MATERIALS ARE TO BE APPROVED BY THE ENGINEER. WOODY MATERIA SHALL BE INSTALLED IN 1.0'LIFTS. EACH LIFT SHALL BE COMPACTED WITH THE EXCAVATOR BUCKE AND COVERED WITH A LAYER OF ALLUVIUM OR MIXED SOIL AND GRAVEL TO FORM A DENSE LAYER C WOODY MATERIAL AND ALLUVIAL TO LINES, ELEVATIONS AND GRADES IN THE DRAWINGS. 2. TOE WOOD SHALL EXTEND INTO THE DOWNSTREAM RIFFLE MIN. 10.0'BEYOND THE P.T. 3. UNCONSOLIDATED GRAVEL AND TOPSOIL SHALL BE INSTALLED ABOVE WOODY MATERIAL BEFORE TH LIVE CUTTINGS AND SOIL LIFTS ARE INSTALLED. 4. PLACE LAYER OF LIVE CUTTINGS (MIN. 4'LENGTH) A 2.0'O.C. ON THE GRAVEL AND TOPSOIL LEVELIN COURSE SUCH THAT APPROXIMATELY 6 INCHES TO 1 FOOT OF EACH LIVE BRANCH WILL BE EXPOSE AND THE REMAINDER (2- TO 4') OF EACH LIVE BRANCH WILL BE COVERED BY THE SOIL LIFT. LIV BRANCHES SHALL BE AN EQUAL FRACTION OF BLACK WILLOW (SALIX NIGRA), SILKY WILLOW (SALI SERICEA) AND SILKY DOGWOOD (CORNUS AMOMUM) AND APPROVED BY THE ENGINEER PRIOR T INSTALLATION. 5. INSTALL A SOIL LIFT ABOVE THE LIVE CUTTINGS. THE SOIL LIFT SHALL NOT EXCEED 1.01 THICKNES LIFTS SHALL INCLUDE ALL SOIL PREPARATION, TEMPORARY AND PERMANENT SEEDING AND MULC SOIL LIFTS SHALL USE TWO LAYERS OF BIODEGRADABLE MATTING- 700 G/M2 COIR MATTING (OUTE AND 320 G/M2 EROSION CONTROL BLANKET (INNER). EROSION CONTROL PRODUCTS USED FOR S& LIFTS SHALL BE MADE OF 100% NATURAL FIBERS AND MATERIALS AND BE BIODEGRADABLE UNDE NORMAL CLIMATE CONDITIONS. EROSION CONTROL MATTING CONTAINING PLASTICS OR PLASTI BASED MATERIALS SHALL NOT BE USED. 6. LIVE TRANSPLANTS AVAILABLE ON THE SITE MAY REPLACE SOIL LIFTS AS DIRECTED BY TH ENGINEER. 7. GRADE THE RIVER BANK AT 3:1 TO THE EXISTING GROUND. SEE BANK GRADING DETAIL ON THI SHEET. 8. KEY EROSION CONTROL MATTING IN BENEATH BANK GRADING AREA AND INSTALL MATTING ON AL DISTURBED RIVER BANKS. 9. THE SURFACE OF THIS STRUCTURE SHALL BE FINISHED TO A SMOOTH AND COMPACT SURFACE I ACCORDANCE WITH THE LINES, GRADES, AND CROSS -SECTIONS OR ELEVATIONS SHOWN ON TH DRAWINGS. THE DEGREE OF FINISH FOR ELEVATIONS SHALL BE WITHIN 0.1 FT OF THE GRADES AN ELEVATIONS INDICATED OR APPROVED BY THE ENGINEER. 10.RE-DRESSING OF CHANNEL AND BANKFULL BENCH/FLOODPLAIN WILL LIKELY BE REQUIRE FOLLOWING INSTALLATION OF IN -STREAM STRUCTURES AND SHALL BE CONSIDERED INCIDENTAL T CONSTRUCTION. ROCK TOE PROTECTION WITH SOIL LIFT SPECIFICATIONS 1. ROCK USED IN THE ROCK TOE PROTECTION STRUCTURE SHALL CONSIST OF 100% NCDOT CLASS RIPRAP. RIPRAP SHALL BE INSTALLED IN 1.0' LIFTS. EACH LIFT SHALL BE COMPACTED WITH TH EXCAVATOR BUCKET AND COVERED WITH A LAYER OF ALLUVIUM AND GRAVEL AVAILABLE ONSITE AN WITHIN THE RIVER BED TO FORM A DENSE LAYER OF COMPACTED ROCK MATERIAL TO LINE ELEVATIONS AND GRADES IN THE DRAWINGS AND DETAILS. 2. GRAVEL AND TOPSOIL SHALL BE INSTALLED AS A LEVELING COURSE ABOVE THE FILTER FABRIC AN RIPRAP BEFORE THE LIVE CUTTINGS AND SOIL LIFTS ARE INSTALLED. 3. PLACE LAYER OF LIVE CUTTINGS (MIN. 4'LENGTH) A 2.0'O.C. ON THE GRAVEL AND TOPSOIL LEVELIN COURSE SUCH THAT APPROXIMATELY 6 INCHES TO 1 FOOT OF EACH LIVE BRANCH WILL BE EXPOSE AND THE REMAINDER (2- TO 4') OF EACH LIVE BRANCH WILL BE COVERED BY THE SOIL LIFT. LIV BRANCHES SHALL BE AN EQUAL FRACTION OF SILKY WILLOW (SALIX SERICEA) AND SILKY DOGWOO (CORNUS AMOMUM). 4. INSTALL A SOIL LIFT ABOVE THE LIVE CUTTINGS. THE SOIL LIFT SHALL NOT EXCEED 1.01 THICKNES LIFTS SHALL INCLUDE ALL SOIL PREPARATION, TEMPORARY AND PERMANENT SEEDING AND MULC SOIL LIFTS SHALL USE TWO LAYERS OF BIODEGRADABLE MATTING- 700 G/M2 COIR MATTING (OUTE M2 AND 320 G/ EROSION CONTROL BLANKET (INNER). EROSION CONTROL PRODUCTS USED FOR S& LIFTS SHALL BE MADE OF 100% NATURAL FIBERS AND MATERIALS AND BE BIODEGRADABLE UNDE NORMAL CLIMATE CONDITIONS. EROSION CONTROL MATTING CONTAINING PLASTICS OR PLASTI BASED MATERIALS SHALL NOT BE USED. 5. THE SURFACE OF THIS STRUCTURE SHALL BE FINISHED TO A SMOOTH AND COMPACT SURFACE I ACCORDANCE WITH THE LINES, GRADES, AND CROSS -SECTIONS OR ELEVATIONS SHOWN ON TH DRAWINGS. THE DEGREE OF FINISH FOR ELEVATIONS SHALL BE WITHIN 0.1 FT OF THE GRADES AN ELEVATIONS INDICATED OR APPROVED BY THE ENGINEER. 6. RE -DRESSING OF CHANNEL AND BANKFULL BENCH/FLOODPLAIN WILL LIKELY BE REQUIRE FOLLOWING INSTALLATION OF IN -STREAM STRUCTURES AND SHALL BE CONSIDERED INCIDENTAL T CONSTRUCTION. CL CL i i i i i i i < Y z 3: Y < ct L T F co Z 0 co 0 g: UJ C) E UJ 31 (D D m E Q X D 0 6� a- > a- ). . ) L :R —� z Z Z E 0 0 0 z �z < 0 0 S 0 (D 0 (D 3: z L w < Lu 0� < 0 Z < Lij GO N E z 0 D Lij w Lu z < LIJ 0 2 LIJ D 0 Lij 0 LIJ 0 D z co 0— (1) LL u— 0 0 Z z < C) Z 0 B E D ), D —3 D E D 7 ). . ASHEVILLE, NC 28805 ) L :R � N E D D D DATE: 1/22/2024 NOT TO SCALE SHEET NUMBER 4.5 LO C) 04 C) 04 cli N _0 c 0 LLI F- 0 _j 0- C) uj _j U) 0 w OF. SO cf) Lp 0) 'IT N C) 04 c\f 04 2 0 w U) U) 0� r 0 w Q 75 w w F- U) U) —LENGTH VARIES PER PLAN ____4 .4 ... ... ... ... ... ... COMPACTED FILL ATERIAL OLD CHANNEL TOP OF BANK OLD CHANNEL TOE OF SLOPE DETAILED PLAN NOT TO SCALE TOP SOIL MIN. 1.0' OLD CHANNEL — TOP OF BANK IMIN. 1.0' PLUG SLOPE TO LINES, GRADES AND COMPACTED F1 ELEVATIONS SHOWN MATERIAL S 01 IN THEPLANS /WW/ OLD CHANNEL BOTTOM EXISTING GROUND DETAILED SECTION A - AV NOT TO SCALE CHANNEL PLUG CHANNEL PLUG SPECIFICATIONS 1. ALL CHANNEL WORK SHALL TAKE PLACE DURING DRY WORKING CONDITIONS. THE CONTRAC' SHALL MINIMIZE THE EXPORT OF SEDIMENT TO ADJACENT SURFACE WATERS TO THE MAXI� EXTENT PRACTICABLE BY USING E&SC MEASURES AS NEEDED. 2. FOR INSTALLATION, THE CONTRACTOR SHALL PLACE SUITABLE CLAY FILL MATERIAL IN THE EXIS1 CHANNEL UP TO THE TOP OF BANK. FILL MATERIAL SHOULD BE LOCATED WITHIN THE SITE , APPROVED FOR USE BY THE ENGINEER. THE CHANNEL PLUG SHALL BE COMPACTED AS DIREC AND UNTIL APPROVED BY THE ENGINEER ON SITE. 3. TOP SOIL SUITABLE FOR ESTABLISHING NATIVE VEGETATION SHALL BE INSTALLED ON TOP OF COMPACTED FILL MATERIAL TO A MINIMUM DEPTH OF 05ABOVE THE COMPACTED FILL MATERIAL. 4. TRANSPLANTS AVAILABLE ONSITE MAY BE INSTALL IN THE TOP SOIL AS DIRECTED BY THE ENGIN ON SITE. 5. THE SURFACE OF THIS STRUCTURE SHALL BE FINISHED TO A SMOOTH AND COMPACT SURFAC ACCORDANCE WITH THE LINES, GRADES, AND CROSS -SECTIONS OR ELEVATIONS SHOWN ON DRAWINGS. 6. RE -DRESSING AND STABILIZATION OF THE SURROUNDING WORK AREA WITH TEMPORARY PERMANENT SEEDING AND MULCHING WILL LIKELY BE REQUIRED FOLLOWING INSTALLATION OF DITCH PLUG AND SHALL BE CONSIDERED INCIDENTAL TO CONSTRUCTION. CL i i i i i i i < FOR z 1UM 'ING Z \ND co 0 TED 0 Lu g: Lu U) W THE EER (D I N Q ui 0 THE a. w i i i i i i i \ND THE z Z Z _j 0 D 0 0 0� z �z < c) < 0 0� < 0 (D cf) 0 (D 3: z _j �_ C/) D < �_ 0� �: < Lu 0 < Lu cf) < �: Z 0� C) 0 z LL1 - LLJ 2 0 W z 0 < LL1 c) o� LLJ Lu 0 LL] cl� 0 z 13� 00 n c/) LL C) LL 0 I­ 0 Z z < C) Z < 0 Jennings Environmental 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 DATE: 1/22/2024 NOT TO SCALE SHEET NUMBER 4.6 0� ON C) 04 C) 04 c4 c\l 2 0 w 0 —j CL w U) w F.�7 r- 07 0) It c\l C) c\l C4 04 c cu 0 w U) r 0 EROSION & SEDIMENT CONTROL PLAN TO BE DETER SEE SHEETS 5.2 - 5.5 FOR TYPICAL NOTES AND DET INED. ILS. cy) C) N C) 04 cli 04 c - cu 3 0 w 0 _j CL co uj 0 U) 0 Lu 3 W_ r-4 (0 cy) ,It 04 C) 04 cli N 5 0 LL1 U) U) 0 _j w 0 0 U) w U) EROSION AND SEDIMENTATION CONTROL (ESC NOTES AND SPECIFICATIONS 1. ALL CONSTRUCTION ACTIVITIES SHALL ADHERE TO THE CONDITIONS AND REQUIREMENTS OF NC DEMLR'S NG01 CONSTRUCTION GENERAL PERMIT. 2. ALL TREES, UTILITIES AND OTHER SITE FEATURES SHALL BE PROTECTED UNLESS MARKED FOR REMOVAL OR RELOCATION. 3. EQUIPMENT SHALL BE WELL —MAINTAINED, CLEANED PRIOR TO MOBILIZATION, AND CHECKED DAILY FOR LEAKS OF PETROLEUM PRODUCTS. FUELING OPERATIONS SHALL BE PERFORMED IN A CONTAINED AREA AWAY FROM SURFACE WATER. 4. ALL WORK IN OR ADJACENT TO STREAMS AND RIVERS SHALL BE CONDUCTED SUCH THAT THE FLOWING WATER DOES NOT COME IN CONTACT WITH THE DISTURBED WORK AREA. 5. UTILIZE A TEMPORARY IN —STREAM DIVERSION AND/OR PUMP AROUND SYSTEM AT ALL TIMES WHEN WORKING IN THE ACTIVE STREAM CHANNEL. 6. CONSTRUCTION SHALL BE TIMED TO OCCUR DURING TIMES OF LOW FLOW. 7. CONSTRUCTION SCHEDULING AND STAGING SHALL BE TIMED TO MINIMIZE THE AMOUNT OF TIME SPENT WORKING IN THE RIVER CHANNEL. 8. THE RIVERBANKS, IN —STREAM STRUCTURES AND WORK AREA MUST BE STABILIZED AT THE END OF EACH DAY BEFORE THE TEMPORARY IN —STREAM DIVERSIONS ARE REMOVED AND FLOW IS RETURNED THE FULL CHANNEL. 9. ALL WASTE SOIL SHALL STAY ONSITE AND WILL BE DISPOSED OF IN AREAS DESIGNATED ON THE PLANS. THE WASTE SOIL FOR THE FUTURE WALKING TRAIL SHALL BE ROUGH —GRADED AND STABILIZED WITH TEMPORARY AND PERMANENT SEEDING AND MULCH SEQUENCE OF CONSTRUCTION 1. OBTAIN AND REVIEW THE PROJECT PLANS, EROSION A SEDIMENTATION CONTROL PLAN, AND ALL OTH APPLICABLE PERMITS. 2. FLAG THE WORK LIMITS AND STAKE OUT THE LIMITS DISTURBANCE (LOD) OF THE PROJECT. THE TOTAL PROJE LOD IS TO BE DETERMINED. 3. LOCATE ALL UNDERGROUND UTILITIES WITHIN THE WO AREA. 4. INSTALL RAIN GAUGE AND PREPARE INSPECTION FORMS. 5. HOLD PRE —CONSTRUCTION MEETING WITH THE PERMITTI ENGINEER AND CONTRACTOR PRIOR TO STARTING A LAND DISTURBING ACTIVITIES. 6. INSTALL ALL EROSION AND SEDIMENTATION CONTROL BM AS SHOWN IN THE DRAWINGS AND DETAILS. 7. INSPECT EROSION PREVENTION AND SEDIMENT CONTR BMPS DAILY AND AFTER SIGNIFICANT RAINFALL EVEN' MAKE NEEDED REPAIRS IMMEDIATELY. KEEP ALL LOGS A RECORDS UP—TO—DATE. 8. ACQUIRE AND STORE MATERIALS FOR SITE (E.G. RO( LOGS, EROSION CONTROL MATTING AND FILTER FABRICS) THE TEMPORARY STAGING AREAS. 9. CLEAR EXISTING VEGETATION REQUIRED TO COMPLE THE WORK TAKING CARE NOT TO DISTURB DESIRAE VEGETATION TO REMAIN INTACT. 10. GRADE THE RIVER BANKS AND INSTALL BANK STABILIZATI, STRUCTURES ACCORDING TO THE PLANS AND DETAI WHEN POSSIBLE, PERFORM WORK FROM THE RIVER BAN TO MINIMIZE TIME SPENT WORKING IN THE CHANNEL. 11.WHEN WORKING IN THE CHANNEL, UTILIZE A TEMPORA IN —STREAM DIVERSION. 12.INSTALL TEMPORARY SEEDING, PERMANENT SEEDING, A EROSION CONTROL MATTING ON ALL DISTURBED RIV BANKS AND GRADED SLOPES AS SHOWN ON ESC A RE —VEGETATION PLANS. 13.INSTALL TEMPORARY AND PERMANENT SEEDING A MULCH TO ALL AREAS DISTURBED FOR CONSTRUCTI, ACCESS AND STAGING. 14.ONCE THE WORK AREA IS STABILIZED AND CONSTRUCTI, ACTIVITIES ARE COMPLETED, REMOVE AND DISPOSE OF � NON —BIODEGRADABLE EROSION AND SEDIMENTATI, CONTROL BMPS. 15.NOTIFY THE PERMITEE AND THE ENGINEER FOR A FIN INSPECTION AND WALK THROUGH TO VERIFY FIN STABILIZATION OF THE SITE. 16.WHEN SEASONALLY APPROPRIATE, INSTALL PERMANE PLANTINGS ON RIVER BANKS AND WITHIN THE RIPARI ZONES AS SHOWN ON RE —VEGETATION PLAN. CL CL 0 < ND z ER OF Z 0 CT co RK ::E 0 NY PS OL FS. ND Z 0 Z D _j 0 �z 0 0 z 0 '%#K) < 0� < 0 (D IN 0 (D m z w < 0� U) w TE �— < 0 Z F- 0 cf) LE �: Z z 0 uj W ui Z 2u) (—) C) DN 0� C) UJ 1 0 0 uj 0� 0 z (]� 00 a_ LL KS E3 C) Z u- 0 I— 0 O� < z z RY 3: 0 ND ER ND ND DN Jennings DN �LL Environmental DN 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 AL AL NT AN DATE: 1/22/2024 SCALE (34"X22"): NTS SCALE (1 7X1 1 "): NTS NOT TO SCALE SHEET NUMBER 5.2 �-F SO u') 9 04 9 C) N C) 04 c\f 04 c - cu 3 w 0 -i CL co uj 0 U) 0 Lu 3 w— r-4 (0 cy) ,It 04 C) 04 04 N M 5 0 LL1 U) U) 0 U) w 0 0 U) w U) STEEL POST PLASTIC WIRE T1 ZZ z x 8'MAX. STANDARD STRENGTH FABRIC WITH WIRE FENCE 6'MAX. EXTRA STRENGTH FABRIC WITHOUT WIRE FENCE W I R E F E N C E -4 18-24" OR ES 2411 FILTER FABRIC ELEVATION NOT TO SCALE ZZ >z x TEMPORARY GRAVEL CONSTRUCTION ENTRANCE/EXIT PLASTI WIRE STEEL POST 8" DOWN & 4" FORWARD ALONG THE TRENCH I All - - I �� /— FILTER FABRIC BACKFILL TRENCH AND COMPACTTHOROUGHLY UPSLOPE 8" MIN. MIN. CROSS SECTION NOT TO SCALE TEMPORARY SILT FENCE TEMPORARY IN -STREAM DIVERSION NOTES AND SPECIFICATIONS CONSTRUCTION- 1. CLEAR THE ENTRANCE AND EXIT AREA OF ALL VEGETATION, ROOTS, AND OTHER OBJECTIONABI MATERIAL AND PROPERLY GRADE IT. 2. PLACE THE GRAVEL TO THE SPECIFIC GRADE AND DIMENSIONS SHOWN ON THE PLANS, AND SMOO� IT. 3. PROVIDE DRAINAGE TO CARRY WATER TO A SEDIMENT TRAP OR OTHER SUITABLE OUTLET. 4. USE GEOTEXTILE FABRICS IN ORDER TO IMPROVE STABILITY OF THE FOUNDATION IN LOCATIOl' SUBJECT TO SEEPAGE OR HIGH WATER TABLE. MAINTENANCE- 1. PER NCG-01 INSPECT AT LEAST ONCE A WEEK AND AFTER EACH 1 INCH OR GREATER RAINFAL MAKE ANY REQUIRED REPAIRS IMMEDIATELY. 2. MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING TF CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC TOPDRESSING WITH 2 INCH STONE. 3. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED OR TRACKED ONI PUBLIC ROADWAYS. TEMPORARY SILT FENCE NOTES AND SPECIFICATIONS CONSTRUCTION: 1. CONSTRUCT THE SEDIMENT BARRIER OF STANDARD STRENGTH OR EXTRA STRENGTH SYNTHET FILTER FABRICS. 2. ENSURE THAT THE HEIGHT OF THE SEDIMENT FENCE DOES NOT EXCEED 24 INCHES ABOVE TF GROUND. (HIGHER FENCES MAY IMPOUND VOLUMES OF WATER SUFFICIENT TO CAUSE FAILURE THE STRUCTURE) 3. CONSTRUCT THE FILTER FABRIC FROM A CONTINUOUS ROLL CUT TO THE LENGTH OF THE BARRIE TO AVOID JOINTS. WHEN JOINTS ARE NECESSARY, SECURELY FASTEN FILTER CLOTH ONLY AT SUPPORT POST WITH 4 FEET MINIMUM OVERLAP TO THE NEXT POST. 4. SUPPORT STANDARD STRENGTH FILTER FABRIC BY WIRE MESH FASTENED SECURELY TO TF UPSLOPE SIDE OF THE POSTS. EXTEND THE WIRE MESH SUPPORT TO THE BOTTOM OF THE TRENC FASTEN THE WIRE REINFORCEMENT, THEN FABRIC ON THE UPSLOPE SIDE OF THE FENCE POS- WIRE OR PLASTIC ZIP TIES SHOULD HAVE A MINIMUM 50 POUND TENSILE STRENGTH. 5. WHEN A WIRE MESH SUPPORT FENCE IS USED, SPACE POSTS A MAXIMUM OF 8 FEET APAR SUPPORTS SHOULD BE DRIVEN SECURELY INTO THE GROUND A MINIMUM OF 24 INCHES. 6. EXTRA STRENGTH FILTER FABRIC WITH 6 FOOT POST SPACING DOES NOT REQUIRE A WIRE ME�c SUPPORT FENCE. SECURELY FASTEN THE FILTER FABRIC DIRECTLY TO POSTS. WIRE OR PLASTIC Z TIES SHOULD HAVE A MINIMUM OF 50 POUND TENSILE STRENGTH. 7. EXCAVATE THE TRENCH APPROXIMATELY 4 INCHES WIDE AND 8 INCHES DEEP ALONG TF PROPOSED LINE OF THE POSTS AND UPSLOPE FROM THE BARRIER. 8. PLACE 12 INCHES OF FABRIC ALONG THE BOTTOM AND SIDE OF THE TRENCH. 9. BACKFILL THE TRENCH WITH SOIL PLACED OVER THE FILTER FABRIC AND COMPACT. THOROUC COMPACTION OF THE BACKFILL IS CRITICAL TO SILT FENCE PERFORMANCE. 10. DO NOT ATTACH FILTER FABRIC TO EXISTING TREES. MAINTENANCE- 1 INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH 1 INCH OR GREATE RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. 2. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE, OR BECON INEFFECTIVE, REPLACE IT PROMPTLY. 3. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR TF NEXT RAIN AND REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FEN( DURING CLEANOUTS. 4. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA I GRADE AND STABILIZE IF AFTER CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. CL CL < z .E co Z 0 'H co 0 g: UJ UJ Is (D Q L; 0 IE .0 z ZZ I 0 D 0 0 z < c) 0 0� < 0 (D 0 (D 3: z cf) 0 Z) �- w D < Lu �- 0 < < �: Z W z W Ld C) W 0� LLJ z 0 u) 0� 0 1 0 w LLJ 0 z 13� 00 LL C) LL 0 I-- 0 Z z < C) Z < 0 C IE )F .R A Jennings IE Environmental H. T. 7 SAMUEL ASHE DRIVE T. ASHEVILLE, NC 28805 ;H IP IE ;H .R IE IE DATE: 1/22/2024 'E SCALE (34"X22"): NTS .0 SCALE (1 7"X1 1 "): NTS NOT TO SCALE SHEET NUMBER 5.3 �_F So 77 04 9 C) 04 C) N cli 04 c: m cu 0 w 0 —i CL co uj 0 U) 0 Lu co cy) ,It 04 C) 04 04 N Ll m m 5 0 U) U) ui U) w U) APPROVED SEDIMENT FILTERING DEVICE (SEDIMENT FILTER BAG OR APPROVED EQUIVALENT). PROVIDE POSITIVE DRAINAGE FROM SEDIMENT FILTER DEVICE TO STREAM. DISCHARGE ONTO STABLE RIPRAP PAD TO PREVENT SCOUR HOLE FLOW�l_ � 2.0' _MIN._� r� N NC DOT ,�� C::� z CLASS B < RIPRAP ftaffiffo%liff '=4105 7// FILTER FABRIC — TYPICAL BERM CROSS-SECTION yv NOT TO SCALE TEMPORARY PUMP AROUND < NOTES AND SPECIFICATIONS z ct 1. BERMS SHALL BE SITUATED AT THE UPSTREAM AND DOWNSTREAM ENDS OF THE WORK AREA, AND STREAM FLOW SHALL BE PUMPED AROUND THE WORK AREA. THE PUMP SHOULD DISCHARGE ONTO A STABLE VELOCITY DISSIPATER CONSTRUCTED OF RIPRAP OR SANDBAGS. DIVERSION PUMP co STREAM DIVERSION PUMP DISCHARGE SHALL NOT GENERATE SCOUR, EROSION, OR THE EXPORT OF EXCESS SEDIMENT TO Z DISCHARGE HOSES 0 SURFACE WATERS. co 0 g: LLJ p 2. WATER FROM THE WORK AREA SHALL BE PUMPED TO A SEDIMENT FILTERING MEASURE SUCH AS A ui INTAKE HOSE SEDIMENT BAG OR OTHER APPROVED DEVICE. THE MEASURE SHALL BE LOCATED SUCH THAT THE DE -WATERING PUMP WATER DRAINS BACK INTO THE CHANNEL BELOW THE DOWNSTREAM SANDBAG DIKE WITHOUT CAUSING FURTHER EROSION. (D 3. THE CONTRACTOR SHALL SIZE THE PUMP AROUND SYSTEM SUFFICIENTLY FOR A RANGE OF Q POSSIBLE BASEFLOW DISCHARGES AND THE SYSTEM SHALL RUN CONTINUOUSLY WHILE WORKING > 0 IN THE STREAM. FLO\N 4. IN -STREAM DIVERSION MAY BE CONSTRUCTED OF SANDBAGS, RIPRAP (NCDOT CLASS B, OR EQUIVALENT), AND/OR EXISTING BED AND BANK MATERIAL APPROVED BY THE ENGINEER. HEIGHT OF DIVERSION SHALL BE EQUAL TO '2 THE EXISTING BANK HEIGHT + 1.0 FOOT FOR PROJECTS WITH INTAKE DURATIONS LESS THAN 2 WEEKS; 2-YEAR FLOOD ELEVATION FOR PROJECTS OF LONGER DURATION. HOSE SUMP -HOLE FOR POOL TEMP.BERM (12" TO 18" DEEP, 2-FT DIAMETER) 5. THE STREAMBANKS AND WORK AREA MUST BE STABILIZED AT THE END OF EACH DAY BEFORE THE PUMP AROUND SYSTEM IS SHUT DOWN AND BEFORE FLOW IS RETURNED THE CHANNEL. SEQUENCE OF CONSTRUCTION- 0 0 z 1. SET UP PUMP WITH SUCTION AND DISCHARGE HOSE. �z 0 0 WORK AREA < c) 2. INSTALL UP -STREAM TEMPORARY BERM. [)� < 0 (D (LENGTH NOT TO EXCEED THAT WHICH 0 (D 3: z 0 D U) CAN BE COMPLETED IN ONE DAY) 3. INSTALL DOWN -STREAM TEMPORARY BERM. w < 0� �: —i H yj 0 < :;� (SEE NOTE 4) DETAILED PLAN 4. THE PUMP MUST RUN CONTINUOUSLY WHILE WORKING IN THE STREAM. < Z cl) �: ul z NOT TO SCALE 5. STREAMBANKS MUST BE STABILIZED AT THE END OF EACH DAY. W LLJ 0 W z C) 0� LLJ 0 U) 0� 0 Lu 0 LLJ 0 z co w u— u- a_ I­ Z 0 0 z TEMPORARY PUMP AROUND < z 0 TEMPORARY BRIDGE CROSSING NOTES AND SPECIFICATIONS 25-FT MINIMUM SILT FENCE (TYP.) DETAILED PLAN NOT TO SCALE ANCHOR BRIDGEMAT TO A TREE, OR OTHER PERMANENT OBJECT WITH SUFFICIENT STRENGTH, USING STEEL CHAIN OR CABLE. Y4 SUPPORTED MINIMUM 6" LIP--\ SURFACE FLOW DIVERSION AGGREGATE APPROACHWAY 2-3" SURGE STONE OR RAILROAD BALLAST BRIDGEMAT STREAM CROSS SECTION NOT TO SCALE Y4SUPPORTED ORIGINAL - STREAMBANK 1. REFER TO "NORTH CAROLINA DIVISION OF FOREST RESOURCES" LITERATURE, INSTALLATION MAINTENANCE GUIDELINES, & "NORTH CAROLINA FORESTRY BMP MANUAL-2006". 2. INSTALL WATER DIVERSION DEVICES (WATER BARS, TURNOUTS, BROAD -BASED DIPS, ETC.) ON BOTH SIDES OF THE MATS. 3. STABILIZE EXPOSED MINERAL SOIL WITH TREE TOPS OR BRUSH DURING MAT INSTALLATION, AND SEEDING/MULCH AFTER MAT REMOVAL. 4. INSTALL MATS TO CREATE A MINIMUM TEN FOOT BRIDGE WIDTH. 5. INCLUDE COARSE AGGREGATE ON THE APPROACHWAY FOR A MINIMUM OF 25 FEET AND SILT FENCE ALONG STREAMBANKS ADJACENT TO CROSSING FOR A MINIMUM OF 25 FEET. MAINTENANCE NOTES: 1. KEEP MATS'SURFACE FREE OF MINERAL SOIL AND DEBRIS THAT COULD ENTER STREAM. SURFACE FLOW DIVERSION 2. PERIODICALLY CHECK MAT HARDWARE; RE -TIGHTEN NUTS & CABLE CLAMPS AS NECESSARY TO 71—FAT 7�� MAINTAIN BRIDGE STRENGTH AND INTEGRITY. 3. IMMEDIATELY REMOVE ANY DEBRIS WHICH ENTERS THE STREAM AT THE CROSSING LOCATION. REMOVAL NOTES: 1. CLEAN OFF BRIDGE SURFACE. 2. REMOVE MATS BY USING MAT CABLE LOOP OR SKIDDER GRAPPLE. 3. PERMANENTLY STABILIZE DISTURBED PORTIONS OF STREAMBANK AND APPROACH ROADS WITH PERENNIAL GRASSES/MULCH (OR WETLAND MIX WHEN APPLICABLE). 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 DATE: 1/22/2024 NOT TO SCALE TEMPORARY BRIDGE CROSSING SHEET NUMBER 5.4 I I �_F So co CD N C) N cq N c - cu 3 cu _0 c 0 w 0 -i CL co uj co ui co CD N 04 cq Ll m :3 C m 5 U) Ld 0 0 U) w T_ U) 10.0'MAX. CONSTRUCTION AREA DO NOT ENTER WARNING SIGN (TYP.) MIMIlliMilliMillil ORANGE, UV RESISTANT P: C-'TPP:Kl TW I ILI I PLASTIC OR WIRE TIES (TYP.) EX.GRADE __T�y -%-a . 4L DnQ'r NOT TO SCALE POLY BARRICADE FABRIC (TYP.) I rill 1111 4011 ELEVATION NOT TO SCALE TIMBER MAT n NEEN TIMBER '\LL BE FILLED OD CHIPS DETAILED PLAN NOT TO SCALE 411 3" 411 3" 411 WARNING SIGN NOT TO SCALE ,E, UV RESISTANT ENSILE STRENGTH �ARRICADE FABRIC (TYP.) NING SIGN 00 CONSTRUCTION SAFETY FENCE fl A M E) I A rl E: D f-% 1 -r C f -r\/ r7) X CONSTRUCTION SAFETY FENCE NOTES AND SPECIFICATIONS 1. NO ADDITIONAL CLEARING AND GRUBBING IS ANTICIPATED FOR THE INSTALLATION OF THE FENCE THE FENCE SHALL BE ERECTED TO CONFORM TO THE GENERAL CONTOUR OF THE GROUND. 2. POSTS SHALL BE SET AT A MAXIMUM SPACING OF 10 FT., MAINTAINED IN A VERTICAL POSITION AND HAND SET OR SET WITH A POST DRIVER. POSTS SHALL BE INSTALLED A MINIMUM OF 2 FT. INTO THE GROUND. IF HAND SET, ALL BACKFILL MATERIAL SHALL BE THOROUGHLY TAMPED. WOOD POSTS MAY BE SHARPENED TO A DULL POINT IF POWER DRIVEN. POSTS DAMAGED BY POWER DRIVING SHALL BE REMOVED AND REPLACED PRIOR TO FINAL ACCEPTANCE. THE TOPS OF ALL WOOD POSTS SHALL BE CUT AT A 30-DEGREE ANGLE. THE WOOD POSTS MAY, AT THE OPTION OF THE CONTRACTOR, BE CUT AT THIS ANGLE EITHER BEFORE OR AFTER THE POSTS ARE ERECTED. 3. THE FENCE GEOTEXTILE SHALL BE ATTACHED TO THE WOOD POSTS WITH ONE 21, GALVANIZED WIRE STAPLE ACROSS EACH CABLE OR TO THE STEEL POSTS WITH WIRE OR OTHER ACCEPTABLE MEANS. 4. WARNING SIGNS TO BE MADE OF DURABLE, WEATHERPROOF MATERIAL. LETTERS TO BE 31, HIGH MINIMUM, CLEARLY LEGIBLE AND SPACED AS DETAILED. PLACE A SIGN AT EACH END OF LINEAR SAFETY FENCING AND 50'ON CENTER THEREAFTER. FOR CONSTRUCTION AREAS LESS THAN 200, IN PERIMETER, PROVIDE NO LESS THAN ONE SIGN PER PROTECTION AREA. ATTACH SIGNS SECURELY TO FENCE POSTS AND FABRIC. 5. THE CONTRACTOR SHALL BE REQUIRED TO MAINTAIN THE SAFETY FENCE IN A SATISFACTORY CONDITION FOR THE DURATION OF THE PROJECT AS DETERMINED BY THE ENGINEER. TEMPORARY TIMBER MATS NOTES AND SPECIFICATIONS 1. TIMBER MATS SHALL BE USED FOR TEMPORARY CONSTRUCTION ACCESS TO TRAVERSE WET HARDWOOD TOP AND/OR MUDDY AREAS ADJACENT TO THE STREAM, TO CROSS THE STREAM AND OTHER ARDS 2"x8" CONCENTRATED FLOW AREAS, AND/OR TO PROTECT EXITING SITE FEATURES. IF BOTH APPROACHES ARE WET AND/OR MUDDY THE TIMBER MAT APPROACH SHALL BE USED ON BOTH SIDES. 2. THE STREAM CROSSING SHALL BE INSTALLED WHEN FLOW IS LOW. THERE SHALL BE MINIMAL TO NO DISTURBANCE OF THE CHANNEL BED AND BANKS AS A RESULT OF INSTALLING THE APPROACHES OR CROSSING. 3. THE LENGTH OF TIMBER MAT REQUIRED TO CROSS THE STREAM OR CONCENTRATED FLOW AREAS SHALL BE SUCH THAT THE TIMBER MAT EXTENDS PAST THE TOP OF BANK ON EACH SIDE OF THE -HARDWOOD CROSSING A SUFFICIENT DISTANCE TO SUPPORT THE MAXIMUM EQUIPMENT SIZE USING THE DTTOM BOARDS CROSSING. OTHER TIMBER MAT DIMENSIONS AND SPECIFICATIONS (INDIVIDUAL TIMBER SIZE, BOLT x8" SPACING, ETC.) SHALL BE PER THE MANUFACTURERS SPECIFICATIONS WITH RESPECT TO THE MAXIMUM EQUIPMENT SIZE USING THE CROSSING. 4. STREAM CROSSINGS SHALL BE INSTALLED WITH THE TIMBER MAT LENGTHS ORIENTED PERPENDICULAR TO THE TOPS OF THE STREAM BANKS. TIMBER MAT STREAM APPROACHES SHALL BE INSTALLED WITH THE TIMBER MAT LENGTHS ORIENTED PARALLEL TO THE TOPS OF THE STREAM BANKS. 5. ALL TIMBER MATS, FILTER FABRIC, AND RIP RAP SHALL BE COMPLETELY REMOVED FROM THE SITE 4-HARDWOOD WHEN THE CROSSING IS REMOVED. TOP BOARDS 2"x8" MATERIAL SPECIFICATIONS: TYPE- LAMINATED 2 PLY MAT MATERIAL: HARDWOOD APPLICATION- STRAIGHT ROADS WITH MODERATE TURNS ON SANDY AND MUDDY ROADS WEIGHT: 1,600 LBS EACH WEIGHT CAPACITY- 40TONS z ct 0 Z 0 co 0 0- LLJ LLj LU = 0 0 Q LU Lu z Z Z -:] 0 D 0 I-_ 0 < c) 0� < 0 0 (D w < Lu 1­- 0 < Z LLJ LLJ LLJ Z LLJ 0 1 0 z 13� co C) LL Z 0 < C) Z < 0 I: I_- z 0 (D z 0 cf) Z) cl) w Z C) u) 0� LLJ 0 Lu LL n 0 z 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 DATE: 1/22/2024 NOT TO SCALE TEMPORARY TIMBER MATS SHEET NUMBER 5.5 0� r_4 C14 1p C) 04 C) 04 C14 c\1 cu 0 w 0 _j CL m uj _j U) w co �q 0) It c\1 C) c\1 04 CN L, cu cu cu 0 w U) cl d w w U) IN A\ _Nt WIF it 0 N. 0 alk X I, v\ � SH, §3 All j N% \-gk, �,Ngf� �j,� IN x & two � NV "Itz: 1k, � xkk /5\A\ iNI\Q I 0 A A X N\ XL ZONE 1: STREAMBANK ILA (TYP) 1\\ ft 0 0 ZONE 2: RIPARIAN BUFFER ZONE 3: UPLAND (TYP) (TYP) (0 N VI NI I Ij A Wc <, cj— V, - 11 q;�, NX _j A 0 too I, Cr \\A, > low _Ij /(D IN— va s� CUMULATIVE AREAS: ZONE 1: STREAMBANK = 1. 18 AC ZONE 2: RIPARIAN BUFFER 5.90 AC ZONE 3: UPLAND 0.96 AC co Z 0 co 0 g: ! ! ! ! ! ! ! ! LU U) LLJ W Q LU > 0 0� > CL W IL z Z Z _j 0 D 0 0 0� z �_ < c) < z 0 < C) (D < 0 (D 3: z �_ C/) D < �_ 0� �: z Lu �- 0 < 0 U) < �: Z 0� C) I— < Z LL] - Lu z 1-- Lu 0 C) W 0� LLJ 0 (D o� C) Lu 0 LLJ LLI > 0 z 13� 00 LL C) LL 0 LLI Ir I­ 0 Z z < z < 0 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 DATE: 1/22/2024 SCALE (34"X22"): ill 75' SCALE (1 7"X1 1 "): 1 150' 0 75 150 SCALE IN FEET SHEET NUMBER 6.1 NE, 04 0) cy) 6� 1p C) 04 C) 04 cli N c m cu _0 c 0 w 0 0 uj 0 U) Lu ) 0') 0') 'IT N C) 04 cli 04 21, cu =3 c - cu 3 0 Lu U) U) 0� r 0 Lu 0 0 z z U) GENERAL RE -VEGETATION AND PLANTING NOTES 1. SOIL PREPARATION ELEMENTS, TEMPORARY AND PERMANENT SEED, AND GROUND COVER SHALL BE SPREAD OVER ALL AREAS WITHIN THE LOD THAT ARE DISTURBED DURING CONSTRUCTION. 2. CONTAINERIZED PLANTS AND BARE ROOT STOCK SHALL BE LOCATED WHERE SHOWN ON PLAN. 3. ADJUSTMENTS TO THE VEGETATION PLAN SHALL BE MADE ONLY IF APPROVED BY THE PROJECT OWNER AND ENGINEER. 4. FINAL VEGETATION SPECIES SELECTION MAY CHANGE DUE TO REFINEMENT OR SPECIES AVAILABILITY AT THE TIME OF PLANTING. SPECIES SUBSTITUTIONS WILL BE COORDINATED BETWEEN THE ENGINEER AND PLANTING CONTRACTOR PRIOR TO THE PROCUREMENT OF PLANT/SEED STOCK. 5. LARGER NATIVE TREE SPECIES TO BE PRESERVED WILL BE FLAGGED BY THE ENGINEER PRIOR TO CONSTRUCTION ACTIVITIES. ANY TREES HARVESTED FOR WOODY MATERIAL WILL BE UTILIZED TO PROVIDE BED AND BANK STABILIZATION AND COVER OR NESTING HABITAT ON THE FLOODPLAIN. ANY EXCESS WOODY MATERIALS MAY USED TO BACKFILL OLD CHANNELS AT THE DIRECTION OF THE ENGINEER. 6. ALL DISTURBED AREAS WILL BE STABILIZED USING TEMPORARY AND PERMANENT SEEDING AS DEFINED IN THE SEEDING SCHEDULE(S) AND THE APPROVED E&SC PLANS. 7. SUPPLEMENTAL PLANTING ACTIVITIES MAY BE REQUIRED WITHIN CONSERVATION EASEMENT(S), IF PRESENT. TEMPORARY SEEDING AND MULCHING NOTES 8. TEMPORARY SEEDING AND MULCHING SHALL BE APPLIED TO ALL AREAS AND ACCESS ROUTES DISTURBED DURING CONSTRUCTION. 9. ALL SEED AND SEED VARIETIES MUST BE FREE OF STATE AND FEDERALLY LISTED NOXIOUS WEED SEED AND INVASIVE SPECIES. 10. ALL DISTURBED AREAS WILL BE SEEDED WITH TEMPORARY SEED AND MULCHED WITH WHEAT STRAW. SEEDING WILL BE PERFORMED USING A BROADCAST SPREADER. OTHER METHODS MAY BE USED BUT MUST BE APPROVED BY ENGINEER IN ADVANCE OF INSTALLATION. 11. MAINTENANCE OF SEEDED AREAS SHALL CONSIST OF WATERING, WEED AND PEST CONTROL, FERTILIZATION, EROSION REPAIR, RESEEDING, AND INCIDENTAL OPERATIONS AS NECESSARY TO ESTABLISH A HEALTHY, VIGOROUS, WEED FREE AND DISEASE FEE UNIFORM STAND OF GRASS. ALL AREAS WHICH FAIL TO SHOW A UNIFORM STAND OF GRASS FOR ANY REASON SHALL BE TREATED REPEATEDLY UNTIL A UNIFORM STAND OF AT LEAST 90% COVERAGE IS ATTAINED WITH NO BARE AREA GREATER THAN FIVE (5) SQUARE FEET. PERMANENT SEEDING NOTES 12. PERMANENT SEEDING SHALL OCCUR IN CONJUNCTION WITH TEMPORARY SEEDING WHERE APPLICABLE. IDEALLY, PERMANENT SEEDING SHALL OCCUR DURING THE PLANTING SEASON FOR EACH SEED TYPE. AREAS FERTILIZED FOR TEMPORARY SEEDING SHALL BE SUFFICIENTLY FERTILIZED FOR PERMANENT SEEDING; ADDITIONAL FERTILIZER IS NOT REQUIRED FOR PERMANENT SEEDING. 13. ALL SEED AND SEED VARIETIES MUST BE FREE OF STATE AND FEDERALLY LISTED NOXIOUS WEED SEED AND INVASIVE SPECIES. 14. THE CONTRACTOR SHALL LOOSEN THE SOIL TO A MINIMUM DEPTH OF 4-INCHES AND GRADE TO A SMOOTH, EVEN SURFACE WITH A LOOSE, UNIFORMLY FINE TEXTURE. THE AREAS TO BE SEEDED ARE THEN TO BE ROLLED AND RAKED TO REMOVE RIDGES AND FILL DEPRESSIONS TO MEET FINISH GRADES. THE CONTRACTOR IS TO LIMIT SUB GRADE AND FINISH GRADE PREPARATION TO AREAS THAT WILL BE PLANTED IMMEDIATELY. PREPARED AREAS ARE TO BE RESTORED IF ERODED OR OTHERWISE DISTURBED AFTER FINE GRADING AND BEFORE PLANTING. 15. SEED SHALL BE SOWN WITH A SPREADER OR A SEEDING MACHINE. SEED IS NOT TO BE BROADCAST OR DROPPED WHEN WIND VELOCITY EXCEEDS 5 MPH. SEED SHALL BE EVENLY DISTRIBUTED BY SOWING IN TWO DIRECTIONS AT RIGHT ANGLES TO EACH OTHER. WET SEED OR SEED THAT IS MOLDY OR OTHERWISE DAMAGED IN TRANSIT OR STORAGE IS NOT TO BE USED. AFTER BEGIN SOWN, THE SEED SHALL BE RAKED INTO THE TOP 1/4 INCH OF THE TOPSOIL, LIGHTLY ROLLED, AND WATERED WITH FINE SPRAY. SEEDED AREAS ON STREAM BANKS SHALL BE PROTECTED WITH COIR FIBER MATTING. BARE ROOTS, LIVE STAKES, & CUTTINGS 16. CUTTINGS SHOULD BE INSTALLED THE SAME DAY THEY ARE CUT. THE STAKE SHOULD BE ORIENTED WITH BUDS POINTED UPY AND THE BOTTOM SHOULD BE CUT AT AN ANGLE FOR EASY INSERTION INTO THE GROUND. 17. ABOUT3/40F THE LENGTH OF THE STAKE SHOULD BE BELOW GROUND AND ANGLED DOWNSTREAM. AN IRON BAR CAN BE USED TO MAKE A PILOT HOLE TO PREVENT BARK DAMAGE DURING INSTALLATION. CONTAINER STOCK 18. STOCK SHALL HAVE BEEN GROWN IN A CONTAINER LONG ENOUGH FOR THE ROOT SYSTEM TO HAVE DEVELOPED SUFFICIENTLY TO HOLD ITS SOIL TOGETHER ONCE REMOVED FROM THE CONTAINER. 19. CONTAINER PLANTS WILL NEED TO BE WATERED REGULARLY AND PLACED IN SHADY CONDITIONS UNTIL PLANTING OCCURS.CREATE PLANTING AREA FOR EACH PLANT AND EXCAVATE PIT. 20. THE DIAMETER OF THE PLANTING HOLES (PITS) FOR EACH 21. PLANT SHOULD BE AT LEAST THREE TIMES THE DIAMETER OF THE ROOT MASS. SCARIFY THE PLANTING PIT PRIOR TO EACH PLANT INSTALLATION. 22. SET PLANTS UPRIGHT IN THE CENTER OF THE PIT. THE BOTTOM OF THE ROOT MASS SHOULD BE RESTING ON UNDISTURBED SOIL. 23. PLACE BACKFILL AROUND BASE AND SIDES OF ROOT MASS, AND WORK EACH LAYER TO SETTLE BACKFILL AND TO ELIMINATE VOIDS AND AIR POCKETS. WHEN PIT IS APPROXIMATELY 2/3 FULL, WATER THOROUGHLY BEFORE PLACING REMAINDER OF THE BACKFILL. WATER AGAIN AFTER PLACING FINAL LAYER OF BACKFILL. PREVENT BARK FROM BEING DAMAGED DURING INSTALLATION. SOIL SPREADING 24. AREAS OF SOIL SPREADING SHALL BE STABILIZED USING TEMPORARY SEEDING AS DEFINED IN THE SEEDING SCHEDULE AND THE APPROVED EROSION AND SEDIMENTATION CONTROL PLANS. ZONE 1: STREAMBANK 25. LIVESTAKES AND HERBACEOUS PLUGS LISTED IN THE PLANTING SCHEDULE SHALL BE PLANTED IN OFFSET ROWS AT A DENSITY OF 4,840 STEMS PER ACRE (3.01 O.C.) FROM TOE OF THE RESTORED CHANNEL TO 3.0'OUTSIDE THE BANKFULL STAGE. HERBACEOUS PLUGS SHALL BE PLANTED ALONG THE TOE OF THE CHANNEL. ZONE 2: RIPARIAN BUFFER 26. WOODY SPECIES LISTED IN THE PLANTING SCHEDULE SHALL BE PLANTED IN OFFSET ROWS AT A DENSITY OF 440 STEMS PER ACRE (10.01 O.C.) FROM 3.01 OUTSIDE THE BANKFULL STAGE TO THE GRADING LIMITS. EXACT PLACEMENT OF THE SPECIES SHALL BE DETERMINED BY THE CONTRACTOR'S VEGETATION SPECIALIST PRIOR TO SITE PLANTING AND BASED ON THE WETNESS CONDITIONS OF PLANTING LOCATIONS. ZONE 3: UPLAND 27. FOLLOW SPECIES LIST AND APPLICATION RATE OF PERMANENT RIPARIAN PLANT/SEEDING. 0 z ct 0 Z 0 co 0 0- LLJ LLj LU = 0 0 Q LU Lu z Z Z - 0 D 0 %J < c) 0� < 0 0 (D w < Lu 0 < Z LLJ LLJ LLJ Z LLJ 0 1 0 z 13� co C) LL K 0 < C) Z 0 U) z Lu 0 (D I­ z 0 c) z z 0 cl) Z 0 Lu LL] Lu 0 n > LL 0 z 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 DATE: 1/22/2024 SCALE (34"X22"): NTS SCALE (1 7"Xl 1 "): NTS NOT TO SCALE SHEET NUMBER 6.2 PLANTING SCHEDULES CL CL NE, 04 C) 15: 04 1p C) 04 C) 04 cli N c m cu _0 c 0 w 0 C) Lu U) Lu ) 0') 04 lz.: Lo 6 'IT 04 C) 04 04 04 21, cu =3 c - cu 3 0 Lu U) U) 0� r 0 Lu z z TEMPORARY SEEDING DATE TYPE APP. RATE (LBS AC) MOUNTAINS, ABOVE 2500 FEET- FEB 15 - MAY 15 MOUNTAINS, BELOW 2500 FEET: FEB 1 - MAY 1 PIEDMONT: JAN 1 - MAY 1 COASTAL PLAIN- DEC 1 - APR 15 RYE GRAIN (Secale cereale) 120 COMMON OATS (Avena sativ) 100 RED CLOVER (Trifolium incarnatum) 20 GROUND AG. LIMESTONE 2,000 10-10-10 FERTILIZER 750 STRAW MULCH 4,000 MOUNTAINS- MAY 15 - AUG 15 PIEDMONT: MAY 1 -AUG 15 COASTAL PLAIN: APR 15 - AUG 15 GERMAN MILLET (Setaria italica) 40 COMMON OATS (Avena sativ) 100 RED CLOVER (Trifolium incarnatum) 20 GROUND AG. LIMESTONE 2,000 10-10-10 FERTILIZER 750 STRAW MULCH 4,000 MOUNTAINS- AUG 15 - DEC 15 COASTAL PLAIN AND PIEDMONT: AUG 15 - DEC 30 RYE GRAIN (Secale cereale) 120 COMMON OATS (Avena sativ) 100 RED CLOVER (Trifolium incarnatum) 20 GROUND AG. LIMESTONE 2,000 10-10-10 FERTILIZER 750 [STRAW MULCH 4,000 PERMANENT RIPARIAN PLANT / SEEDING - 25 LBS / AC SPECIES COMMONNAME PERCENT Juncus effusus COMMON RUSH 15% Coreopsis lanceolata LANCE LEAF TICKSEED 15% Andropogon gerardi BIG BLUESTEM 5% Schizachyrium scoparium LITTLE BLUESTEM 5% Rudbeckia hirta BLACK-EYED SUSAN 15% Chamaecrista (Cassia) fasciculata SHOWY PARTRIDGE PEAR 15% Lobelia cardinalis CARDINAL FLOWER 15% Helianthus angustifolius SWAMP SUNFLOWER 15% TOTAL 100% ZONE 1 - STREAMBANK - 3v O.C. (4,840 STEMS / AC) SPECIES COMMONNAME % OF STEMS LIVE STAKES Comusamomum SILKY DOGWOOD 40% Salix sericea SILKY WILLOW 30% Sambucus canadensis ELDERBERRY 15% Physocarpus opulifolius NINEBARK 15% TOTALI 100% HERBACEOUS PLUGS Juncus effusus COMMON RUSH 60% Carex alata BROADWING SEDGE 40% TOTAL 100% ZONE 2 - RIPARIAN BUFFER - 101 O.C. (440 STEMS AC) SPECIES COMMONNAME % OF STEMS OVERSTORY (60%) Betula nigra RIVER BIRCH 10% Platanus occidentalis SYCAMORE 10% Nyssa sylvatica BLACK GUM 6% Liriodendron tulipifera YELLOW POPLAR 6% Aesculus octandra YELLOW BUCKEYE 6% Tilia americana AMERICAN BASSWOOD 6% Acer rubum RED MAPLE 10% Quercus alba WHITE OAK 6% UNDERSTORY (40%) Diospyros virginiana PERSIMMON 5% Alnus serrulata HAZELALDER 5% Asimina triloba PAWPAW 5% Calycanthus floridus SWEET SHRUB 5% Hamamelis virginiana WITCH HAZEL 5% Lindera benzoin SPICEBUSH 5% Carpinus caroliniana IRONWOOD 5% Oxydendrum arboreum SOURWOOD 5% TOTAL 100% co Z 0 co 0 g: UJ Uj LU (D Q Lu z Z Z _j 0 D 0 0 z �z < c) cf) w 0 0� < (D —J C) 0 (D 3: Z D C/) D < — �: C) LLJ w 0 < I: cl) < �: Z (-) U) z LLJ - W (D 0 W LLJ z 0 1 0 w z 0 z 13� co < LL C) LL 0 a- 0 Z z < z < 0 I: �- 7 SAMUEL ASHE DRIVE ASHEVILLE, NC 28805 DATE: 1/22/2024 SCALE (34"X22"): NTS SCALE (1 7"Xl 1 "): NTS NOT TO SCALE SHEET NUMBER 6.3