HomeMy WebLinkAboutSW6231203_Supplement-EZ Form_20240412 SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
PROJECT INFORMATION
1 'Project Name Gillespie-B1.9 Solar Utility Station
2 Project Area(ac) 40.66
3 Coastal Wetland Area(ac) 0
4 Surface Water Area(ac) 3.09
5 Is this project High or Low Density? Low
6 Does this project use an off-site SCM? No
COMPLIANCE WITH 02H.1003(4)
7 Width of vegetated setbacks provided(feet) _ 50'
8 Will the vegetated setback remain vegetated? Yes
9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? _ N/A
10 Is streambank stabilization proposed on this project? No
NUMBER AND TYPE OF SCMs:
11 !Infiltration System
12 Bioretention Cell
13 Wet Pond
14 Stormwater Wetland
15 Permeable Pavement
16 Sand Filter
17 Rainwater Harvesting(RWH)
18 Green Roof
19 Level Spreader-Filter Strip(LS-FS)
20 Disconnected Impervious Surface(DIS)
21 Treatment Swale
22 Dry Pond
23 StormFilter
24 Silva Cell
25 Bayfilter
26 Filterra
FORMS LOADED
DESIGNER CERTIFICATION
27 'Name and Title: Laura Harris,P.E.,Project Engineer III-Team Lead
28 Organization: Booth&Associates,LLC
29 Street address: 2300 Rexwoods Drive,Suite 300
30 City,State,Zip: Raleigh,NC 27607
31 Phone number(s): 919-851-8770
32 Email: Laura.Harris@booth-assoc.com
Certification Statement:
I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the
information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans,specifications,
operation and maintenance agreements and other supporting information are consistent with the information provided here.
111111111111
Designer //
`?), CAFio /1
'1
N.
SEAL s �' -
1 056748 Signature of Designer
%.,RAG R NPR 04/12/2024
111/11111101
Seal Date
DRAINAGE AREAS
1 Is this a high density project? No
2 If so,number of drainage areas/SCMs 0
3 Does this project have low density areas? Yes
4 If so,number of low density drainage areas 1
Is all/part of this project subject to previous rule
5 versions? No
FORMS LOADED
DRAINAGE AREA INFORMATION Entire Site LD 1
4 Type of SCM N/A N/A
5 Total drainage area(sq ft) 1771150 1771150
6 Onsite drainage area(sq ft) 1771150 1771150
7 Offsite drainage area(sq ft)
8 Total BUA in project(sq ft) 149947 sf 149947 sf
New BUA on subdivided lots(subject to permitting)
9 (so ft)
New BUA not on subdivided lots(subject to
10 permitting)(sf)
11 Offsite BUA(sq ft)
12 Breakdown of new BUA not on subdivided lots:
-Parking(sq ft) 73461 sf 73461 sf
-Sidewalk(sq ft)
-Roof(sq ft)
-Roadway(sq ft) 31831 sf 31831 sf
-Future(sq ft)
-Other,please specify in the comment box below
(sq ft) 16946 sf 16946 sf
New infiltrating permeable pavement on subdivided
13 lots(so ft)
New infiltrating permeable pavement not on
14 subdivided lots(sq ft)
Existing BUA that will remain(not subject to
15 permitting)(sq ft) 27709 sf 27709 sf
16 Existing BUA that is already permitted(sq ft)
17 Existing BUA that will be removed(sq ft)
18 Percent BUA 9% 9%
19 Design storm(inches) 1.0 in 1.0 in
20 Design volume of SCM(cu ft) N/A N/A
21 Calculation method for design volume N/A N/A
ADDITIONAL INFORMATION
Please use this space to provide any additional information about the
22 drainage area(s):
LOW DENSITY
DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H.1003
1 Is project below density thresholds set forth in the applicable stormwater rule? Yes
2 Does project maximize dispersed flow and minimize channelization of flow? Yes
3 Has the use of piping been minimized per.1003(2)(c)? Yes
4 Side slopes of the vegetated conveyances(H:V)
5 Maximum velocity in the vegetated conveyances during the 10-year storm?
6 Are curb outlet swales proposed? No
7 Maximum longitudinal slope of curb outlet swale(s)(%) N/A
8 Bottom width of curb outlet swale(s)(feet) N/A
9 Maximum side slope of curb outlet swale(s)(H:V) N/A
10 Minimum length of curb outlet swale(s)(feet) N/A
11 Are treatment swales used instead of curb outlet swales? No
12 Is stormwater released at the edge of the setback as dispersed flow? Yes
13 Have stormwater outlets been designed to prevent downslope erosion? Yes
14 Are variations to rule.1003 proposed? No
ADDITIONAL INFORMATION
15 Please use this space to provide any additional information about this low density project:
There are no permanent vegetated conveyences,those shown in the drawing set are temporary and are to be removed once
permanent vegetation is established.
Drainage Pervious
Swale Area BUA area C Q Slope Vanow V,ct,,,i Flow depth
# (ac) (ac) (ac) (cfs) (%) (fps) (fps) (ft)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30