Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCC241143_Site Plan or Location Map_20240415
APPROVED FOR CONSTRUCTION L �j • DATE:4/4/2024 o Z PROJECT NUMBER:LDCP-2023-00327 61 I�RIN l:_ NOTE THIS PLAN APPROVAL DOES NOT INCLUDE CHARLOTTE WATER.FOR CA EASE CALL 704 336 S499 or v,=,1«adottewa, C/� U 0 CHARLOTTE- SCHEDULE PRE-CONSTRUCTIONTO A W I 1 MECKLENBURGANY LAND DISTURBING ACTIVITY U G THE ONLINE FORM FOUND AT �( N gIo/4eveIPPmeVicenhr slry PLAN VING DEPARTMENT NOTE:THIS PLAN APPROVAL DOES NOT INCLUDE COMMERCIAL ZONING.e c ALLLi Ir.: 314 KLENSU6337COUNTY OR MORE CODE INFORMATION. PLEASE CALL RAC AT 704- I a �( O BUILDING GRAHAM STREET TOWN H O M ES o � � z CHARLOTTE, MECKLENBURG COUNTY, NORTH CAROLINA - ACCELA PROJECT#:LDCP-2023-00327 3 D ,w CONSTRUCTION DOCUMENTS o Ew-, /'0/ W , S /( Ct o N o GrIB CC OO- �.J 0 0N' C W LL o U o O m rn Z 0L ° Illl,plllllllglry/ w \�o���N•CARp��,, - :0 9 GENERAL NOTES: Sheet List Table Q SDLL !•`• 055352 1. EXISTING BOUNDARY AND TOPOGRAPHIC INFORMATION SHOWN IN THIS PLAN IS Sheet Number Sheet Title / GlVY1J BASED UPON A COMBINATION OF A SURVEY PROVIDED AND GIS DATA.GATEWAY DESIGN GROUP DOES NOT REPRESENT OR WARRANT THE WORK PREPARED BY THE C-0.0 COVER SHEET +•••.•NC1110-R:'Q .` SURVEYOR. C-1.0 SITE SURVEY �!4'Pt A.p�pM0�`O 2. THE CIVIL ENGINEER AND THE OWNER DISCLAIM ANY ROLE IN THE CONSTRUCTION '711111 1 1 1 1 1 1111111`VV\\ MEANS AND/OR METHODS ASSOCIATED WITH THE PROJECT AS SET FORTH IN THESE UNIVERSITY C-1.1 EXISTING CONDITIONS&DEMO PLAN 2024.09.01 08:26:25-04W VARIABLE WIDTH PUBLIC,OIp BOULEVARD ' C-2.0 SITE PLAN PLANS. ( LANE BOULEVARD) 3. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE TO ENFORCE SAFETY MEASURES PER MB.65 PG 392 C-2.1 SIGHT DISTANCE PLAN&PROFILE _ OR REGULATIONS.THE CONTRACTOR SHALL DESIGN,CONSTRUCT,AND MAINTAIN ALL OBw-Osw C-2.2 SITE DETAILS ° SAFETY STANDARDS,LAWS,AND REGULATIONS. ' o: om. �� 4.CONTRACTOR SHALL NOTIFY GATEWAY DESIGN GROUP 48 HOURS PRIOR TO THE v C-3.0 EROSION CONTROL PLAN-PHASE 1 a COMMENCEMENT OF CONSTRUCTION ACTIVITIES. _` C-3.1 EROSION CONTROL PLAN-PHASE 2 OO 5. ALL LOCAL,MUNICIPAL,AND STATE LAWS,RULES,AND REGULATIONS GOVERNING OR - il o RELATING TO ANY PORTION OF THIS WORK ARE HEREBY INCORPORATED INTO AND N ETI _M xw-ONw. C-3.2 EROSION CONTROL DETAILS MADE PART OF THE PROJECT CONTRACT DOCUMENTS AND THEIR PROVISIONS SHALL 066 BE CARRIED OUT BY THE CONTRACTOR. / O ■ W. O C-3.3 EROSION CONTROL DETAILS 6. DO NOT SCALE DRAWINGS IN THIS SET.ALL WRITTEN DIMENSIONS SHALL TAKE _gf r. Cd.O GRADING PLAN PRECEDENCE OVER THE SCALE SHOWN ON THE PLANS,SECTIONS,PROFILES,AND �- Cd.1 STORM SEWER DRAINAGE AREAS CO DETAILS.IN THE EVENT OF DISCREPANCIES,THE CONTRACTOR SHALL REQUEST CLARIFICATION FROM THE CIVIL ENGINEER AND/OR OWNER'S REPRESENTATIVE. 10 i I O CAI STORM SEWER DETAILS 1 1 1 N7. IF DEPARTURES FROM THE PROJECT DRAWINGS OR SPECIFICATIONS ARE DEEMED C-5.0 UTILITY PLAN 1 1 1 CVNECESSARY BY THE CONTRACTOR,DETAILS OF SUCH DEPARTURES AND REASONS 5NTHERE OF SHALL BE BUBMITTED TO THE CIVIL ENGINEER ANDIOR OWNER'S11 .� O C-5.1 UTILITY DETAILS G OJ G N REPRESENTATIVE FOR REVIEW.NO DEPARTURES FROM THE CONTRACT DOCUMENTS / � -� t- C6.0 LANDSCAPE PLAN 0 (� SHALL BE MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE CIVIL - -� z ENGINEER AND/OR OWNER'S REPRESENTATIVE. C6.1 LANDSCAPE DETAILS T 8. THE SURVEYOR SHALL REPORT ANY ENCROACHMENTS OR DISCREPANCIES / © ■ ■ O C-7.0 BMP DETAIL SHEET 1 w GENERATED BY THE SITE PLAN AGAINST ANY DEVELOPMENT REQUIREMENTS 167 SPECIFIED BY THE SITE PLAN TO THE CIVIL ENGINEER AND/OR OWNER'S11111.11111711117111111Wi C-7.1 BMP DRAINAGE AREAS L 0 REPRESENTATIVE PRIOR TO ANY ACTUAL CONSTRUCTION. as 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING EXISTING ■ O (") CONDITIONS PRIOR TO COMMENCEMENT OF ANY WORK.THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE CIVIL ENGINEER AND/OR OWNER'S REPRESENTATIVE OF , A_ rii O -6 ANY DISCREPANCIES OR CONFLICTS. 10.ALL SUB-SURFACE UTILITIES IDENTIFIED ON THE CONSTRUCTION DOCUMENTS ARE 14 ■ I SHOWN IN THEIR APPROXIMATE LOCATION BASED ON SURVEY INFORMATION TI GATHERED FROM FIELD INSPECTION AND/OR ANY OTHER APPLICABLE RECORD e I ® i U DRAWINGS WHICH MAY BE AVAILABLE.THE CONTRACTOR SHALL CONFIRM THE ,PII LOCATION OF ALL UNDERGROUND UTILITIES PRIOR TO COMMENCEMENT OF ANY ■ O w w WORK.THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE CIVIL ENGINEER AND/OR 0 MUM 6 u) OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES OR CONFLICTS. 11.THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING,COORDINATING AND ■ ® PAYMENT FOR ALL NECESSARY LOCATING SERVICES INCLUDING INDEPENDENT •! + XTEM . LOCATING SERVICES.THE CONTRACTOR SHALL PROVIDE NOTICE OF EXCAVATION TONOTIFICATION CENTER AND FACILITY OWNERS(PER NC STATUTE)NO LESS THAN 3 BUSINESS DAYS AND NO MORE THAN 12 WORKING DAYS PRIOR TO BEGINNING ' �.� ON DEMOLITION,EXCAVATION OR ANY OTHER FORM OF CONSTRUCTION. A`..�.�.�pr r , I CO rn 12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE RELOCATION OF ANY EXISTING ♦+����'�� �I .. a UTILITY LINES REQUIRED TO COMPLETE ANY PORTION OF CONSTRUCTION.THE ♦j�®0,������ I I I I I Xi Li CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE COORDINATION AND COSTS OF ��s��� I I r_ i THE RELOCATION AND ASSOCIATED WORK. ®�� ( ut 13.THE CONTRACTOR SHALL PROTECT ALL EXISTING UTILITIES,LANDSCAPING,AND GREEN I \ I a w FEATURES TO REMAIN ON AND/OR ADJACENT TO THE PROJECT SITE DURING ♦ AREA I \ I I DEVELOPER: I < O CONSTRUCTION.THE CONTRACTOR SHALL REPAIR OR REPLACE,AT THEIR OWN �� I FOUR CORNERS OF CHARLOTTE,LLC /r EXPENSE,ALL DAMAGED ELEMENTS RESULTING FROM CONTRACTOR OPERATIONS \` o OR NEGLIGENCE. , I I I 1612 SEATLLE SLEW COURT 14.THE CONTRACTOR SHALL BE RESPONSIBLE TO IMMEDIATELY REPAIR ANY ACTIVE WAXHAW,NC 28173 % UTILITIES THAT ARE DAMAGED DURING CONSTRUCTION AT CONTRACTOR'S EXPENSE. ♦ 1`e v I ROMIL CHUDGAR 0_ 15.THE CONTRACTOR SHALL REPAIR ANY DAMAGE TO THE PUBLIC RAN(RIGHT-OF-WAY) I A I (704)713-2602 N IN ACCORDANCE WITH THE STANDARDS OF CDOT AND CITY OF CHARLOTTE. ♦ 1 to D I rumelle03@yahoo.com 3 16.THE CONTRACTOR SHALL CONTACT THE UTILITY COMPANY TO RELOCATE/REPLACE 13 m I j �ANV EXISTING UTILITY AND/OR LIGHT POLES.ALL EXISTING FACILITIES WHICH I \ I DESIGNER: o CONFLICT WITH THE IMPROVEMENTS UNDER THE SCOPE MUST BE RELOCATED AT THE CONTRACTOR'S EXPENSE. I\ GATEWAY DESIGN GROUP,PLLC % 17.ALL TESTING SHALL BE PERFORMED BY A QUALIFIED TESTING LABORATORY, , \ 8516 FOXBRDGE DR EMPLOYED AND PAID DIRECTLY BY THE OWNER.TESTING SHALL BE PERFORMED,AT WEDDINGTON,NC 28104 co A MINIMUM,IN ACCORDANCE WITH THE RECOMMENDATIONS IN THE GEOTECHNICAL 'N1/\ ____ \ �_- I MARK DIAMOND,P.E. REPORT.IN THE EVENT THE RESULTS OF THE INITIAL TESTING DO NOT COMPLY WITH - (919)368-8867 THE PLANS AND THE SPECIFICATIONS,SUBSEQUENT TEST NECESSARY TO -_- mark@gatewaydesigngroup.com DETERMINE THE ACCEPTABILITY OF CONSTRUCTION SHALL BE AT THE _ CONTRACTORS EXPENSE.ELEMENTS FOUND TO BE DEFICIENT IN STRENGTH OR 1 THICKNESS SHALL BE REMOVED AND REPLACED SOLELY AT THE EXPENSE OF THE , I SURVEYOR: CONTRACTOR. I I TIDEMARK LAND SERVICES 18.PRIOR TO BEGINNING CONSTRUCTION,THE GENERAL CONTRACTOR SHALL VERIFY I 3556 CENTRE CIR SUITE A THAT ALL REQUIRED PERMITS AND APPROVALS HAVE BEEN OBTAINED FROM ALL FORT MILL,SC 29715 REGULATORY AUTHORITIES. I JULIE MCDONALD 1 II 19.GENERAL CONTRACTOR SHALL MAINTAIN THE SITE IN A MANNER SO THAT WORKMEN ThtiI'1'\ (704)201-8898 PA AND PUBLIC ARE PROTECTED FROM INJURY. \ )mcdNnald@tidemarkland.Com 20.THE GENERAL CONTRACTOR SHALL CONTACT ALL OWNERS OF EASEMENTS, W UTILITIES,AND RIGHT-OF-WAYS,PUBLIC AND PRIVATE,PRIOR TO WORKING IN THESE jAREAS. W\ DOoNN N 21.ANY DISCREPANCIES FOUND IN THE FIELD SHALL BE CALLED TO THE ATTENTION OF \ /'U(/ <<Y/.�� \ y THE OWNER OR ENGINEER PRIOR TO PROCEEDING WITH WORK. \\RRW\ R'W(PER BC$/•NE \ 5 44 22.ALL DRAINAGE FACILITIES,CURB CUTS,AND CURB RAMPS MUST BE CONSTRUCTED IN \ P`^1 \ rc COMPLIANCE WITH THE NCDOT AND CHARLOTTE LAND DEVELOPMENT STANDARDS IW G.220) 'o MANUAL AND COORDINATED WITH CITY ENGINEERING DEPARTMENT. j 23.CONTRACTOR TO OBTAIN BUILDING DEMOLITION PERMIT AS REQUIRED PER ALL W APPLICABLE REGULATIONS. w ...ALL STANDARD NUMBERS REFER TO THE LATEST EDITION OF THE CITY OF CHARLOTTE W\ Q LAND DEVELOPMENT STANDARDS MANUAL AND THE NCDOT STANDARD DETAILS AND SPECIFICATIONS. '811• p �T WWW.nD811.Or9 PROJECT 4.2023-039 DATE:04/01/2024 GRAPHIC SCALE DRAWN BY:MD CHECKED BY:JB v APPROPRIATE PARSIES AND ASSURING THAT EXISTING ARE LOCATED PRIOR TO BEGINNING CONSTRUCTION. UTILITIES TITLE "I''''''' D sll 2. CONTRACTOR IS RESPONSIBLE FOR PUOING FLAG MEN,ETC.AS NECESSARY TO INSURE SAFETY.BARRICADES USING COVER SHEET '2 I ALL PAVEMENT CUTS,CONCRETE OR ASPHALT,ARE TO BE REPLACED ACCORDING TO STANDARDS OP THE NORTH CAROLINA N (IN FEET) DEPARTMENT OF TRANSPORTATION AND LOCAL MUNICIPALITIES. SHEET NO. UHORIZONTAL 1 inch=40 fL PART 1926 SUBPART P.OR AS AMENDED.TRENCHING STANDARDS C-U•0