Loading...
HomeMy WebLinkAboutAdd Info Received 202404111 Winston, Joey From:Mckenzie Beyer <mbeyer@enviroscienceinc.com> Sent:Thursday, April 11, 2024 3:51 PM To:Winston, Joey Subject:[External] RE: Request for Additional Information, Thomas Valley Rd Driveway, Jackson County (DWR #20240245) Attachments:new4.11.24.Clipped impact drawings printed.pdf; Additional Info following pcnUPDATED.pdf CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Hello, Please see my responses to your quesƟons as well as the accompanying aƩachments. Ms. Beyer, On February 13, 2024, the Division of Water Resources (Division) received your applicaƟon requesƟng a 401 Water Quality CerƟficaƟon from the Division for the subject project. The Division has determined that your applicaƟon is incomplete and cannot be processed. The applicaƟon is on-hold unƟl all of the following informaƟon is received: 1. Many of the labels on the project plans cannot be read. Please submit plans of sufficient quality that labels and features are clearly displayed. [15A NCAC 02H .0502(a)(9)] Please see the aƩached updated impact drawings. Several text boxes have been wriƩen over, and all other text should be legible upon zooming in. 2. The project plans appear to show an exisƟng culvert crossing of the stream; however, it is not menƟoned in the project descripƟon or history. The PCN menƟons an exisƟng gravel drive but does not include informaƟon on a culvert associated with this road. Please clarify whether an exisƟng culvert is present and whether it will be removed as part of this project. Please include applicable impact measurements. [15A NCAC 02H .0502(a)(4); 15A NCAC 02H .0502(a)(9)] Please see the aƩached updated ‘addiƟonal info following pcn’ document SecƟon B.3e. The pre-exisƟng culvert cannot be uƟlized due to several safety issues. It is also not proposed for removal at this Ɵme. 3. The PCN does not include a descripƟon of measures taken to avoid or minimize the proposed impacts in designing the project (the PCN says to see addiƟonal informaƟon following PCN form, but this quesƟon is not included in the addiƟonal informaƟon). Please include a descripƟon of these measures, including why 98 feet of impacts are required and why the exisƟng culvert, if present, cannot be uƟlized. [15A NCAC 02H .0506(b)(1)] Please see the aƩached updated ‘addiƟonal info following pcn’ document with avoidance and minimiza Ɵon details. Pursuant to Title 15A NCAC 02H .0502(c), the applicant shall furnish all of the above requested informa Ɵon for the proper consideraƟon of the applicaƟon. Please provide your response by May 10, 2024. If all of the requested informaƟon is not received, the Division will be unable to approve the applicaƟon and it will be denied as incomplete. The denial of this project will necessitate reapplicaƟon to the Division for approval, including a complete applicaƟon package and appropriate fee. Please let me know if you have any ques Ɵons. 2 Please let me know if you need any addiƟonal informaƟon. Thank you, McKenzie Beyer Biologist EnviroScience, Inc O. 828.698.9800| C. 704.302.5978 From: Winston, Joey <joey.winston@deq.nc.gov> Sent: Wednesday, April 10, 2024 4:44 PM To: Mckenzie Beyer <mbeyer@enviroscienceinc.com> Subject: Request for Additional Information, Thomas Valley Rd Driveway, Jackson County (DWR #20240245) Ms. Beyer, On February 13, 2024, the Division of Water Resources (Division) received your applicaƟon requesƟng a 401 Water Quality CerƟficaƟon from the Division for the subject project. The Division has determined that your applicaƟon is incomplete and cannot be processed. The applicaƟon is on-hold unƟl all of the following informaƟon is received: 1. Many of the labels on the project plans cannot be read. Please submit plans of sufficient quality that labels and features are clearly displayed. [15A NCAC 02H .0502(a)(9)] 2. The project plans appear to show an exisƟng culvert crossing of the stream; however, it is not menƟoned in the project descripƟon or history. The PCN menƟons an exisƟng gravel drive but does not include informaƟon on a culvert associated with this road. Please clarify whether an exisƟng culvert is present and whether it will be removed as part of this project. Please include applicable impact measurements. [15A NCAC 02H .0502(a)(4); 15A NCAC 02H .0502(a)(9)] 3. The PCN does not include a descripƟon of measures taken to avoid or minimize the proposed impacts in designing the project (the PCN says to see addiƟonal informaƟon following PCN form, but this quesƟon is not included in the addiƟonal informaƟon). Please include a descripƟon of these measures, including why 98 feet of impacts are required and why the exisƟng culvert, if present, cannot be uƟlized. [15A NCAC 02H .0506(b)(1)] Pursuant to Title 15A NCAC 02H .0502(c), the applicant shall furnish all of the above requested informa Ɵon for the proper consideraƟon of the applicaƟon. Please provide your response by May 10, 2024. If all of the requested informaƟon is not received, the Division will be unable to approve the applicaƟon and it will be denied as incomplete. The denial of this project will necessitate reapplicaƟon to the Division for approval, including a complete applicaƟon package and appropriate fee. Please let me know if you have any ques Ɵons. Thanks, Joey Joey Winston Environmental Specialist II, Division of Water Resources North Carolina Department of Environmental Quality Office: (828) 296-4685 | Cell: (828) 785-9171 joey.winston@deq.nc.gov 3 Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties by an authorized state official.