Loading...
HomeMy WebLinkAbout20050732 Ver 34_Final Plans for Boyd Devane_20151218v�MCIQM&CREED TO: NCDENR - Division of Water Resources 401 & Buffer Permitting Unit 512 N. Salisbury St. Archdale Building - 9th floor Raleigh, NC 27604 ATTENTION: Mr. Boyd Devane LETTER OF TRANSMITTAL DATE: December 4, 2015 PROJECT NO: 2735-0151 TASK NO: EXT RE: Briar Chapel - Phase 10 TRANSMITTAL NO: 1 PAGE 1 OF 1 WE ARE SENDING: ❑ Originals ® Prints ❑ Shop Drawings ❑ Samples ❑ Specifications ® Calculations ❑ Other - Quantity Dwg No. Rev. Description Status 1 Cover Letter Requesting Stormwater Management Plan Approval G 2 Stormwater Design Plans G 2 Narrative & Supporting Calculations G 2 BMP #25 Design Supplement G 2 BMP #25 O&M Agreement G Issue Status Code: - A. Preliminary B. Fabrication Unly U. tror intormanon u. Dia E. Construction F. For Review & Comments G. For Approval H. See Remarks REMARKS: Boyd, Please find the enclosed documents for your review and approval. Please let us know if you have any questions or comments. Thank you. 1730 Varsity Drive, Suite 500 Raleigh NC 27606 919/33-8091 Fax 919/233-8031 Cc: McKIM & CREED, INC. n .11a.� a 0� Signed — DECD Gareth Avant, PE 1 02015 PHASE 10 CONSTRUCTION DOCUMENTS U.S. HWY 15-501 and MANN'S CHAPEL ROAD COUNTY AND AGENCY CONTACTS A. Chatham County Planning Department Dunlap Building 80 East Street Pittsboro, NC 27312 (919) 542-8204 phone Contact: Jason Sullivan Email: jason.sullivan@chathamnc.org B. Chatham County Environmental Services Dunlap Building 80 East Street Pittsboro, NC 27312 (919) 542-0945 phone Contact: Dan LaMontagne, PE Email: dan.lamontagne@chathamnc.org C. Chatham County Soil Erosion and Sedimentation Control Dunlap Building 80 East Street Pittsboro, NC 27312 (919) 545-8339 phone Contact: Rachael Thorn Email: rachael.thorn@chathamnc.org D. Chatham County Public Works 964 East Street, 2nd Floor, Suite 205 Pittsboro, NC 27312 (919) 545-8530 phone Contact: Larry Bridges Email: larry.bridges@chathamnc.org E. NCDOT Division 8, District 1 300 DOT Drive P.O. Box 1164 Asheboro, NC 27204 (336) 318-4000 phone Contact: Justin Richardson, PE Email: jrichardson@ncdot.gov F. NCDENR Division of Water Quality 512 N. Salisbury St Archdale Building, 9th Floor Raleigh, NC 27604 (919) 807-6373 phone Contact: Boyd Devane Email: boyd.devane@ncdenr.gov G. NCDENR Division of Environmental Health Public Water Supply Section 1634 Mail Service Center Raleigh, NC 27699-1634 (919) 707-9064 phone Contact: Shashi Bhatta Email: shashi.bhatta@ncdenr.gov H. NCDENR Division of Water Quality Surface Water Protection 3800 Barrett Drive Raleigh, NC 27609 (919) 791-4200 phone Contact: Danny Smith Email: danny.smith@ncdenr.gov CHATHAM COUNTY., NORTH CAROLINA DATE: DECEMBER 4,2015 "06 MANN'S CHAPEL RD TO CHAPEL HILL NORTH � J O ;GREAT tD PKWY "j BRIAR, Uj CPKWY � � � ( BRIAR BOULDER ; POINT DR I✓ � ;�, CHAPELPKWY i NORf SITE WS STOR VICINITY MAP- NOTTO SCALE TO PITTSBORO VICINITY MAP NTS v BRIAR'A�CHAPEL v by Newland COMMUNITIES PROJECT DATA NAME OF PROJECT: BRIAR CHAPEL - PHASE 10 CHATHAM COUNTY, NORTH CAROLINA OWNER: NNP BRIAR CHAPEL, LLC 16 WINDY KNOLL CIRCLE CHAPEL HILL, NC 27516 PHONE: (919) 951-0700 FAX: (919) 240-4963 CONTACT: LEE BOWMAN EMAIL: Ibowman@newlandco.com PREPARED BY: McKIM & CREED 1730 VARSITY DRIVE, SUITE 500 RALEIGH, NORTH CAROLINA 27606 PHONE: (919) 233-8091 FAX: (919) 233-8031 CONTACT: GARETH AVANT, PE EMAIL: gavant@mckimcreed.com PROJECT AREA: 19.20 ACRES These improvements shall be constructed in accordance with the following plans, and the Standard Specifications of NCDOT and Chatham County. MCM4&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com SHEET INDEX C0.1 COVER SHEET C0.2 EXISTING CONDITIONS/DEMOLITION PLAN C1.0 SITE PLAN C2.0 UTILITY PLAN C3.1 STAGE 1 GRADING, DRAINAGE, & EROSION CONTROL PLAN C3.2 STAGE 2 GRADING, DRAINAGE, & EROSION CONTROL PLAN C4.1 PLAN & PROFILE ROAD A - STA 18+55 TO STA 28+67 C4.2 PLAN & PROFILE ROAD C - STA 10+00 TO STA 16+02 ALLEY FG -3 - STA 10+00 TO STA 15+71 C4.3 PLAN & PROFILE ROAD F - STA 10+00 TO STA 21+39 C4.4 PLAN & PROFILE ROAD G - STA 10+00 TO STA 22+94 C4.5 PLAN & PROFILE STORM OUTFALL - STA 10+00 TO STA 13+64 D1.1 EROSION AND SEDIMENTATION CONTROL DETAILS D1.2 EROSION AND SEDIMENTATION CONTROL DETAILS D2.1 NCDOT ROADWAY DETAILS D2.2 NCDOT DRAINAGE DETAILS D2.3 GUARDRAIL DETAILS D3.1 UTILITY DETAILS D3.2 UTILITY DETAILS D4.1 BMP #25 PLAN & DETAILS D4.2 BMP #25 PLAN & DETAILS D4.3 BMP #25 PLAN & DETAILS D4.4 STORM DRAINAGE & SANITARY SEWER TABLES AL 036348 036348 G;. 12/04/2075: CALL N.C. ONE CALL CENTER BEFORE YOU DIG STOP 1-800-632-4949 AVOID UTILITY \ DAMAGE / FINAL DRAWINGS FOR REVIEW PURPOSES ONLY C:) W Q n 0 M ti N 0 J z O U) W U) O n ry n W LU ry O LL U) cD z Q ry 0 J Q z_ LL LOT AREA TABLE LOT # AREA (SF) AREA (AC) 1695 6902.73 0.16 1696 5125.00 0.12 1697 5125.00 0.12 1698 5125.00 0.12 1699 5125.00 0.12 1700 6164.16 0.14 1701 5226.39 0.12 1702 5200.00 0.12 1703 5200.00 0.12 1704 5200.00 0.12 1705 5200.00 0.12 1706 5200.00 0.12 LOT AREA TABLE LOT # AREA (SF) AREA (AC) 1707 5200.00 0.12 1708 6805.47 0.16 1709 1 6250.00 0.14 1710 6250.00 0.14 1711 6250.00 0.14 1712 6976.66 0.16 1713 5260.00 0.12 1714 5260.00 0.12 1715 5260.00 0.12 1716 5260.00 0.12 1717 5260.00 0.12 1718 5260.00 0.12 145 k -_- II I I I I 1458 � I I I I I I LOT AREA TABLE LOT # AREA (SF) AREA (AC) 1719 5292.76 0.12 1720 8232.68 0.19 1721 1 5850.00 0.13 1722 5850.00 0.13 1723 5850.00 0.13 1724 8056.12 0.18 1725 1 5850.00 0.13 1726 5850.00 0.13 1727 5747.04 0.13 1728 10507.85 0.24 1729 1 13160.63 0.30 1730 1 8618.79 0.20 LOT AREA TABLE LOT # AREA (SF) AREA (AC) 1731 8618.79 0.20 1732 8687.22 0.20 1733 1 7884.53 0.18 1734 7232.50 0.17 1735 6576.08 0.15 1736 6568.97 0.15 1737 1 6568.97 0.15 1738 6568.97 0.15 1739 7796.93 0.18 1740 6871.66 0.16 1741 6325.00 0.15 1742 6325.00 0.15 CARDINAL RIDGE ROAD LOT AREA TABLE LOT # AREA (SF) AREA (AC) 1743 6325.00 0.15 1744 6870.78 0.16 1745 5200.00 0.12 1746 5200.00 0.12 1747 5200.00 0.12 1748 5200.00 0.12 1749 5200.00 0.12 1750 5200.00 0.12 1751 5226.39 0.12 1752 5914.16 0.14 1753 5125.00 0.12 1754 5125.00 0.12 10'X70' SIGHT TRIANGLE (TYP.) (27' B -B, 50' PUBLIC R/W) - - moi--, / / 101_42'- _ - - ( _26.71' -13.51'-= 40_00 - =40.00 = X0.00'- - X0_00' - -40.00'- - _ -40.00'= - = i - _105_00 I'o I 69 0 I �� 125.00_ - I I I I I I 120.0' L- I I 01 1719 1718 171 1716 1715 714 1713 12 05 0 I .I 69 0 0 0 0 0 0 0 � LOT AREA TABLE LOT # AREA (SF) AREA (AC) 1755 5125.00 0.12 1756 5125.00 0.12 1757 1 5914.16 0.14 1758 5226.39 0.12 1759 5200.00 0.12 1760 5200.00 0.12 1761 5200.00 0.12 1762 5200.00 0.12 1763 5200.00 0.12 1764 5200.00 0.12 1765 5338.16 0.12 1766 4800.00 0.11 LOT AREA TABLE LOT # AREA (SF) AREA (AC) 1767 4800.00 0.11 1768 4800.00 0.11 1769 1 4800.00 0.11 1770 4800.00 0.11 1771 4800.00 0.11 1772 4800.00 0.11 1773 1 4800.00 0.11 1774 4800.00 0.11 1775 4800.00 0.11 1776 4800.00 0.11 1777 1 5314.52 0.12 1778 1 4846.16 0.11 LOT AREA TABLE M M r7 r7 r7 ;- iM LOT # AREA (SF) AREA (AC) 1779 3840.00 0.09 1780 3840.00 0.09 1781 1 3840.00 0.09 1782 3840.00 0.09 1783 3840.00 0.09 1784 3840.00 0.09 1785 3840.00 0.09 1786 3840.00 0.09 1787 3840.00 0.09 1788 3840.00 0.09 1789 3840.00 0.09 1790 3840.00 0.09 LOT AREA TABLE LOT # AREA (SF) AREA (AC) 1791 3840.00 0.09 1792 3840.00 0.09 1793 4846.52 0.11 SITE GENERAL NOTES: /\ MANN'S CHAPEL RD 1. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY NORTH J OWNER IF ANY DISCREPANCIES EXIST PRIOR TO CONSTRUCTION. NO ADDITIONAL COMPENSATION WILL BE PAID TO THE CONTRACTOR FOR ANY WORK EAT DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THE PLANS IF SITE SUCH NOTIFICATION HAS NOT BEEN GIVEN. 2. STREAM AND WETLAND LOCATIONS ARE BASED ON DELINEATIONS PROVIDED BY L -IL SOIL AND ENVIRONMENTAL CONSULTANTS IN RALEIGH, NC - CONTACT NIKKI L THOMSON AT 919-846-5900. / 3. A PORTION OF THIS PROPERTY IS LOCATED IN SPECIAL FLOOD HAZARD AREA "AE" AS SHOWN ON FEMA FIRM MAP #3710976500J DATED FEBRUARY 2, 2007. 4. ALL PROPOSED ROADWAY DIMENSIONS AS SHOWN ARE MEASURED FROM BACK OF CURB TO BACK OF CURB, ALL PROPOSED ALLEY DIMENSIONS AS SHOWN ANoRf ARE MEASURED FROM EDGE OF PAVEMENT TO EDGE OF PAVEMENT, UNLESS Sri NOTED OTHERWISE. 5. BEFORE STARTING ANY CONSTRUCTION OF IMPROVEMENTS WITHIN ANY NCDOT STREET OR HIGHWAY RIGHT-OF-WAY, CONTACT NCDOT DISTRICT OFFICE AND VICINITY MAP OBTAIN ALL PERMITS AND ENCROACHMENTS. KEEP COPIES ON CONSTRUCTION NOT TO SCALE SITE. ALSO CONTACT NCDOT DISTRICT OFFICE 24 HOURS IN ADVANCE BEFORE PLACING CURB AND GUTTER AT 336-629-1423. 6. REFER TO PLAN AND PROFILE SHEETS FOR DETAILED SANITARY SEWER AND STORM DRAINAGE INFORMATION WITHIN PUBLIC ROADS. j CHATHAM COUNTY CHATHAM COUNTY REQUIRED SITE NOTES 10' NO -BUILD BUFFER (TYP.) 1. PROPERTY OWNER /DEVELOPER: I I / NNP BRIAR CHAPEL, LLC 16 WINDY KNOLL CIRCLE I I I CHAPEL HILL, NC 27516 I I I PHONE: (919) 951-0700 R1-1 I I I I 2. SITE AKPAR #: 2714 STOP CHATHAM COUNTY \ RIPARIAN BUFFER (TYP.) --------------------------�---- \ EX. PUMP STATION 3+55 19+00 N90'00'00"E 20t 00 _ _ 21+OOC �� 212.20'T AR01-�� (DESIGNED_ BY OTHERS) -. ���--4pPueucRROAD G7' -110.00- 55.00- .00 0.2-0 0 50.00'- ----------- ------__--- - - "I o'Y PUBLIC DRAINAGE EASEMENT 01 I 72 '9 4' PRIVATE UTILITY OI STOP 9EASEMENT (TYP) 4' HOA EASEMENT �:� ��� / PUBLIC DRAINAGE I III (TYP) X839 23 �� _ _ �- EASEMENT - 73 73 I // / N �\ 10 I I IIIII I I I 0 l 1711 T± o I I 1721 0 PUBLIC DRAINAGE III /co \� \\\ _ J 125.00 - - PUBLIC DRAINAGE n 1 I O UAN \\ .0' CONCRETE SIDEWALK I I I I I I EASEMENT I I EASEMENT I 1731 I I 1 - L � L -1 L -1 L -1 I - - I 30" STANDARD L -1 -I\kgs \ \\\ (TYP.) _ 69 125.00 1 CURB &GUTIER (TYP.) BMP MAINTENANCE AND 0 I I / 30" STANDARD \ �\ ACCESS EASEMENT Lo I I o I c�i < CURB & GUTTER (TYP.) \ \ A \ (I �Q \ /'V 40.20 40.00 40.00 40.00' 40.00' 40.00 40.00 1710 I I Ic L6' I 72 01 45.00' 1 .00 35.00T 5.30 3 _ �j 0- -40 I I I I u7 0 50 20.5 / 73 \ \ \ \ of 69 I-� _130.00 1 rl� � __T2 -5. 05 0-T r - - .41 /< \\\ \ - R1-1 PRIVATE TE DRAINAGE��� 125.00 I 1 1 1 1 1 1 I II - 00 0l I 72 I EASEMENT0. n I I I-, \ \o \ o I 0 70 I I N i I STOP I s�\ PUBLIC DRAINAGE I� 69 0 ; I EASEMENT 1701 0 70 70 70 70 70 70 L _j I I r 1 24� - pr) L �2 �2 -125 00 1 \ \ o o� I R1-1 I I I I I I I I1-7 I- o I I I I I 'o \ \ `\ '\ - PUBLIC DRAINAGE I 72 0' EASEMENT I I I I I of I I I 10 XS' PUBLIC UTILITY \ ?: 0 I o 4.0' CONCRETE SIDEWALK STOP j I h 72 N I 6r,\ EASEMENT (TYP.) I STOP 70 - (TYP.) 70 ,� I I I c" - 4.0' CONCRETE SIDEWALK d,\ �s t PUBLIC DRAINAGE (TYP.) �\ - Nd; EASEMENT o`x A-------------- -- --- -------•---------- ----- ------ ------ ------------------------------------- --- --- -- ---------------- ----------- I 1 � 1 10_1_00 90'00'00"E 11+00 12+00 13+OOQUARTER GATE TRACE14 00 _15400 0 16+00 17+00 18+OOQUARTER GATE TRACE19+00 20 00 N90'00'00"E 21+00 21 3 II 1 WHEELCHAIR <20� I r - - (2r B -B, ao' c Rnv) - - - r� ~ - - (2r B -B, 4� BLTc R/wj - - I 1 RAMP (TYP) \ 1138.97' 1138.97' 21.10 32.00'132.00- ,32.00---32.00'--32.00'_,32.00- 32.00 32.00 32.00- ,32.00- 2.00 32.00 32.00- -32.00- 2 1 " ` 105 00- - -40.20- - -40.00- 40.00- -40.00- -40.00 -40.00 -40.00- 1 6.46 - I O 1 1 ---- o L��-- ------ ---- -- ----- ---- --- --- --- ---- -- ------------ -- ? �I� L - y - ------ --- ----- -----L-1-- -- ----- --- ------ -- ----- --� ----- - 37 p 2v� VARIABLE WIDTH SIDEWALK R1 1 0 \�' C7 ^' p -� ��\o + oq I EASEMENT (TYP) �I PUBLIC DRAINAGE � F� m I 4' PRIVATE UTILITY F-1 F-1 FF -1 1h'' z c' s 0 I 5 N EASEMENT m �`I - CO o' 75 �' o STOP �� I ``' N I I I 73 I I �I I I I �I �I �I �I 040 > I I N I IEASEMEN T (TYP)I I 4 HOA EASEMENT- 00 74 10X70' SIGHTTRIANGLE Z a I WHEELCHA _ 0 10X8PUBLIC UTILITY I iI' ' UU RAMP (TYP)(rYP.) EASEMENT (TYP.) 0 m 125.00+�1 I I ON O O O O O O O O ® � O O O O I I v o f �R1-1 N l0 0 0 0 0 0 o PUBLIC DRAINAGE I l 77 77 78 1781 78 78 78 78 78 78 7 78 79 1791 79 79 O o O o o o O o ® o EASEMENT I Ld Io 1 I I I I I I I I I I I I I I I I <I 00 01 STOP 75 0 1751 0 75 0 74 0 74 0 74 0 7 0 74 I I- I J o cc c� 0 0 l I I I I I I I I I I I I CURB &NUT ER TYP. I I I I� I� I� I� I� I� o I 74 I o I I 73 I of (TYP.) I I =�- O I N p I PUBLIC DRAINAGE I I PUBLIC DRAINAGE I I I I I I PRIVATE DRAINAGE I I I I I I i t In I I 131.38 - EASEMENT I III EASEMEN T `l� I o I a 12 56 0 EASEMENT -- I 75 0 o I 1 L _32.94 39 nn - 2. 0_Q =2.Q27i2.00- -L�32,0 OU - Q.Q_E-32,00 2.00 (15' E -E, 20' PRIVATE R/W) 45.00 F-40.00 ��F40.00'-1 F-40.00 � F-40.00 -1 40.00 � �-40.00 -1 F-40.00'� 40.00 � �-40.00 -1 F-4 0.00' 40.00 -1 1- 10X8' PUBLIC UTILITY R1-1 i l EASEMENT (TYP.) I I I I I I I I I I to II I I I I I I I I I I I I I I I I I I I I I STOP I I of o 0 0 0 0 0 0 0 0 0 o Ic of 0 0 0 0 0 00 0 0 0 0 o I< 77 0 77 0 77 0 77 0 77 0 77 0 1771 0 77 0 76 0 76 0 76 0 76 0 76 If N N N N N N N N N N N N R1-1 I I I I III III I I I I III III I I I I I I I STOP I 4.0' CONCRETE SIDEWALK 4I ' PRI VA TE UTILITY 4' HOA EASEMENT (TYP.) EASEMENT (TYP) (TYP) so, 7, 1• 0+00 _ X00_ _ 1 HAWK POINT ROAD_ 13+0� 0 N90°00'00"E 1400 (27' B -B, 40' PUBLIC R/W) 1293.65'+ PUBLIC DRAINAGE cI 30" STANDARD - EASEMENT m CURB & GUTTER (TYP.) N SEAL 1 ISSUED FOR PERMITTING 2015.12.04 REV. NO. DESCRIPTIONS DATE IL REVISIONS 1500 .L- 70 125.00_ - -4 -44 0 T 44.Q4T - O.QO'- - 0' - - N- 74 i ; Q 0 i I 73 I of I o o O I O I `i o � � � �i L 30" STANDARD I w- �I �I �I �I �I �I �I CURB & GUTTER (TYP.) O �I IF IF IF IF IF IF IN,�.�1� I- 0 -- 125.00 -- I I I I I I I I I 01 �+ I I I I I I I I to I z m 01 'n o I � � _ 0 1741 STOP I o2 u7 I I 73 I uo->I I I 75 75 75 76 1761 76 76 76 PUBLIC DRAINAGE I Q I I _ 131.38 = I I I --EAA T - I U0 1 10'X8' PUBLIC UTII o I 10X70 SH T TRIANGLEI I I I I I I F_126.50 00 I I ++ o EASEMENT(TYP.) LI TY I I I 0; (TYP.) I I I I I 4' PRIVATE UTILITY Io I I I N 01 ' I 0 00 wc'II p 4.0' CONCRETE SIDEWALK EASEMENT (TYP.) 0 p I I 73 I o 75 - (TYP.) J 0 0 (0 p - --- - - - - -��(� -- - , �' - 1--- 0 0 16+00 17+00 18+00 HAWK POIINT ROAD 19+00 20 00 21+00 I 22 00�N90'00'00"E 22-9 4- - - - - (27'B -B, ao' PUBLIC R/W) + I - - - - - 1293.65' - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ---------------------------------------------------------------------------- --------- --------------------------- WHEELCHAIR BRIAR CHAPEL 100'co WHEELCHAIR I VIEWSHED BUFFER (TYP.) (TYP) RAMP (TYP) 1\ RAMP TYP SEAL 4AL 036348 �'•• 12/04/2015 FNGIN10\..• "////III i I 'M0P0\\\\. A, vMFK1A4 &CR'EL 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com BRIAR CHAPEL by Newland COMMUNITIES TO CHAPEL HILL TO PITTSBORO I I I I I BRIAR CHAPEL PROPERTY I BOUNDARY I I I I I I I I I II / I I LEGEND: I - - - R/W LINE -- FUTURE R/W LINE I EXISTING R/W LINE I - - HOA EASEMENT LINE I - - - - - - - - - - - PUBLIC UTILITY EASEMENT LINE PUBLIC DRAINAGE EASEMENT I - - EXISTING POWER LINE EASEMENT I of OVERHEAD POWER LINE ----------- 10' NO BUILD BUFFER LINE I ----------- RIPARIAN BUFFER LINE - - - - - - - BMP MAINENANCE & ACCESS EASEMENT BRIAR CHAPEL PHASE 10 CHATHAM COUNTY, NORTH CAROLINA SITE PLAN ROADWAY CENTERLINE CALL N.C. ONE CALL CENTER BEFORE YOU DIG STOP 1-800-632-4949 AVOID UTILITY \ DAMAGE / 50' 0 50' 100' SCALE: 1"=50' (Horiz.) DATE: DECEMBER 4, 2015 MCE PROJ. # 02735-0151 DRAWN BSS DESIGNED BSS CHECKED GCA PROJ. MGR. CHS VERTICAL: C 1 . 0 STATUS: FINAL DRAWINGS REVISION FOR REVIEW PURPOSES ONLY 1 M&C FILE NUMBER SCALE C1.X HORIZONTAL' DRAWING NUMBER 1" = 50' VERTICAL: C 1 . 0 N/A STATUS: FINAL DRAWINGS REVISION FOR REVIEW PURPOSES ONLY 1 STAGE 2 CONSTRUCTION SEQUENCE: 8. BEGIN FINAL GRADING OPERATIONS FOR ROADWAY. STORM DRAINAGE NOTES: 9. ALL FLARED END SECTIONS DISCHARGING INTO WATER QUALITY PONDS WILL SELF INSPECTION NOTICE: HAVE A CONCRETE PAD POURED UNDERNEATH THE FLARED END SECTION IN 9. AS ELEVATIONS ARE BROUGHT TO FINAL GRADES AND STORM PIPING IS INSTALLED 1. STORM DRAINAGE PIPES SHALL BE: ACCORDANCE WITH PROVIDED CONSTRUCTION DETAILS. NOTIFICATION OF LAND RESOURCES SEDIMENT AND EROSION CONTROL SELF -INSPECTION 1. THE INTENT OF THE CONSTRUCTION SEQUENCE IS TO PROVIDE THE CONTRACTOR IN ROADWAY SECTIONS, CONTRACTOR SHALL INSTALL HARDWARE CLOTH AND PROGRAM: WITH A GENERAL GUIDE FOR CONSTRUCTION PURPOSES. THIS SEQUENCE IS NOT GRAVEL INLET PROTECTION AS SHOWN ON PLANS. RCP CLASS III FOR STORM DRAINAGE INSIDE PUBLIC RIGHT-OF-WAY OR 10. RIM ELEVATIONS OF STORM DRAIN STRUCTURES SHALL BE FIELD VERIFIED. INTENDED TO OUTLINE ALL CONSTRUCTION ACTIVITIES ON THIS PROJECT. / THE SEDIMENTATION POLLUTION CONTROL ACT WAS AMENDED IN 2006 TO REQUIRE CONNECTING INTO STRUCTURE INSIDE PUBLIC RIGHT-OF-WAY IN ACCORDANCE 11. STORM DRAINAGE WITHIN PRIVATE EASEMENTS TO BE OWNED, OPERATED AND THAT PERSONS RESPONSIBLE FOR LAND -DISTURBING ACTIVITIES INSPECT A PROJECT 2. ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITH 10. DRAINAGE AT THE REAR OF LOTS 1579-1602 SHALL BE DIRECTED INTO NEW TDDS WITH NCDOT STANDARDS UNLESS NOTED OTHERWISE. MAINTAINED BY HOME OWNER'S ASSOCIATION OR AGENT THEREOF. AFTER EACH PHASE OF THE PROJECT TO MAKE SURE THAT THE APPROVED EROSION INT THE CHATHAM COUNTY SOIL EROSION AND SEDIMENTATION CONTROL ORDINANCE. 40 AND #41. SLOPE DRAINS SHALL BE PLACED SUCH THAT THEY DO NOT AND SEDIMENTATION CONTROL PLAN IS BEING FOLLOWED. RULES DETAILING THE INTERFERE WITH RETAINING WALL CONSTRUCTION. 2. ALL CONCRETE SHALL MEET A MINIMUM 3,000 PSI COMPRESSIVE STRENGTH. 12. LENGTHS SHOWN FOR STORM DRAINAGE PIPES ARE MEASURED FROM CENTER DOCUMENTATION OF THESE INSPECTIONS TOOK EFFECT OCTOBER 1, 2010. THE 3. ALL EROSION CONTROL MEASURES SHALL BE INSPECTED WEEKLY AND AFTER 11. CONTRACTOR SHALL ENSURE THAT ALL SEDIMENT LADEN RUNOFF IS DIRECTED TO 3. ALL PIPE IN STORM DRAIN STRUCTURES SHALL BE STRUCK EVEN WITH INSIDE OF STORM STRUCTURES AND TO ENDS OF FLARED END SECTIONS. SLOPES SELF -INSPECTION PROGRAM IS SEPARATE FROM THE WEEKLY SELF-MONITORING RAINFALL EVENTS. NEEDED REPAIRS SHALL BE MADE IMMEDIATELY. ROADWAY INLET PROTECTION PRIOR TO REMOVAL OF ANY SKIMMER SEDIMENT WALL. CALCULATED ARE BASED ON THIS LENGTH. PROGRAM OF THE NPDES STORMWATER PERMIT FOR CONSTRUCTION ACTIVITIES. THE BASINS. NO BASINS SHALL BE REMOVED UNTIL INSPECTED AND APPROVED BY FOCUS OF THE SELF -INSPECTION REPORT IS THE INSTALLATION AND MAINTENANCE OF 4. IF IT IS DETERMINED DURING CONSTRUCTION THAT SIGNIFICANT SEDIMENT IS CHATHAM COUNTY SESC STAFF. 4. THE INTERIOR SURFACES OF ALL STORM DRAINAGE STRUCTURES SHALL BE 13. CB DENOTES CATCH BASINS TO BE INSTALLED IN THE CENTERS OF PAVED EROSION AND SEDIMENTATION CONTROL MEASURES ACCORDING TO THE APPROVED LEAVING THE SITE, DESPITE PROPER IMPLEMENTATION AND MAINTENANCE, THE ALLEYS AND NON -PAVED AREAS. REFER TO NCDOT DETAILS 840.19 AND PLAN. THE INSPECTIONS MUST BE CONDUCTED AFTER EACH PHASE OF THE PROJECT, CONTRACTOR IS OBLIGATED TO TAKE ADDITIONAL CORRECTIVE ACTIONCONTACT POINTED UP AND SMOOTHED TO AN ACCEPTABLE STANDARD USING MORTAR 840.24 ON SHEET D-2.2. AND CONTINUED UNTIL PERMANENT GROUND COVER IS ESTABLISHED IN ACCORDANCE . CHATHAM COUNTY ENVIRONMENTAL QUALITY DEPARTMENT, OWNER'S 12. PERFORM SEEDING AND MULCHING AS REQUIRED IN ACCORDANCE WITH THE MIXED TO MANUFACTURER'S SPECIFICATIONS. WITH NCGS 113A-54.1 AND 15A NCAC 4B.0131. THE SELF -INSPECTION REPORT FORM IS REPRESENTATIVE AND ENGINEER WITH ANY ADDITIONAL MEASURES NEEDED. TEMPORARY AND PERMANENT SEEDING SCHEDULES LOCATED ON SHEET D1.1 AND NOTE #5 OF THIS SEQUENCE 5. ALL BACKFILL SHALL BE NON -PLASTIC IN NATURE, FREE FROM ROOTS, 14. CI DENOTES CURB INLETS TO BE INSTALLED IN THE CURB LINES OF ROADWAYS. AVAILABLE AS AN EXCEL SPREADSHEET FROM VEGETATION MATTER, WASTE CONSTRUCTION MATERIAL E OTHER REFER TO NCDOT DETAILS 840.02 AND 840.03 ON SHEET D-2.2. HTTP: //WWW.DLR.ENR.STATE.NC.US /PAGES /SEDIMENTATION_NEW.HTML . IF YOU HAVE 5. CONTRACTOR SHALL ESTABLISH GROUNDCOVER ON DISTURBED AREAS WITHIN THE 13. ONCE GROUNDCOVER HAS BEEN ESTABLISHED AND OTHER CONSTRUCTION IS QUESTIONS OR CANNOT ACCESS THE FORM, PLEASE CONTACT THIS OFFICE AT (919) NUMBER OF CALENDAR DAYS AFTER COMPLETION OF GRADING PER THE SCHEDULE OBJECTIONABLE MATERIAL. UTILIZED MATERIAL SHALL BE CAPABLE OF BEING 791-4200. BELOW: COMPLETE, CONTACT CHATHAM COUNTY SOIL EROSION AND SEDIMENTATION AND COMPACTED BY MECHANICAL MEANS AND SHALL HAVE NO TENDENCY TO FLOW ENGINEER FOR SITE INSPECTION BEFORE REMOVING ANY TEMPORARY EROSION OR BEHAVE IN A PLASTIC MANNER UNDER THE TAMPING BLOWS OR PROOF GRADUAL SLOPES: (14) CALENDAR DAYS CONTROL MEASURES OR CONVERTING BASINS TO PERMANENT BMPs. ROLLING. MODERATE SLOPES: (10) CALENDAR DAYS 6. MATERIALS DEEMED AS UNSUITABLE FOR BACKFILL PURPOSES BY THE OWNER'S STEEP SLOPES: (7) CALENDAR DAYS REPRESENTATIVE SHALL BE REMOVED AND REPLACED WITH SUITABLE MATERIAL. LIMITS OF DISTURBANCE NOTES: SLOPES ARE AS DEFINED IN THE CHATHAM COUNTY SOIL EROSION AND 7. BACKFILLING OF TRENCHES SHALL BE ACCOMPLISHED IMMEDIATELY AFTER PIPE SEDIMENTATION CONTROL ORDINANCE. IS LAID. THE FILL AROUND THE PIPE SHALL BE THOROUGHLY COMPACTED TO 1. SILT FENCE AND TREE PROTECTION FENCE LINES ALSO DELINEATE THE LIMITS OF 95% OF THE MAXIMUM DRY DENSITY OBTAINABLE WITH THE STANDARD PROCTOR DISTURBANCE. ALL SILT FENCING OR TREE PROTECTION FENCING SHALL BE 6. CONTRACTOR TO POST EROSION CONTROL PERMIT PROMINENTLY ON SITE AT ALL TEST. THE TOP EIGHT (8) INCHES SHALL BE COMPACTED TO 100% STANDARD CHATHAM COUNTY RIPARIAN INSTALLED INSIDE LIMITS OF DISTURBANCE. TIMES. PROCTOR. BUFFERTYP. ( ) 2. LIMITS OF DISTURBANCE BEYOND PREVIOUSLY APPROVED AREAS: 0.20 ACRES 7. CONTRACTOR SHALL ENSURE THAT ALL EROSION CONTROL MEASURES INSTALLED IN 8. UNDER NO CIRCUMSTANCES SHALL WATER BE ALLOWED TO RISE IN EX. TREE PROTECTION FENCE PER BRIAR STAGE 1 ARE OPERATING AS INTENDED PRIOR TO FINAL GRADING OPERATIONS. ANY MEASURES THAT ARE TO BE REMOVED SHALL BE APPROVED BY CHATHAM COUNTY. UNBACKFILLED TRENCHES AFTER PIPE HAS BEEN PLACED. CHAPEL SOUTH CLEARING AND GRUBBING CHATHAM COUNTY 10' PLANS NO -BUILD BUFFER (TYP.) v w \\ >- - LIMITS OF DISTURBANCE EX. C1-309 v V p A TDD #31 (INSTALLED IN STAGE 1 PER 'BRIAR CHAPEL - - - - - - _ SOUTH CLEARING AND GRUBBING PLANS) (TYP.) v - - - SILT FENCE OUTLET GRAVEL BAG INLET _ , z V PROTECTION (TYP.) EX. C`1-10-102 Q SILT �FENCE TREE L-=- -- . . m \_ - -\� _ EX. SDMH-10-101PROTECTION (TYP.) - - - - - EX. HW -10-100 - \ O O O O O O ��� i- RIPRAP OUTLET PROTECTION /ARDINAL RIDGE ROAD 2 O O O� O O O O ) CA �� - SEE SHEET D1.1 (27' B -B, 50' PUBLIC R/W) (27, B� pVL)GE R �D - v EX. C1-10-107 EX. Cl -305 �_� \ - - -- - - - -- - 69� EX. C1-304 � EX. C1-302 II EX. Cl 306 I I 1 (1712)/ I EX C1 -300A EX. C1-301 I I I I I I I I C1-10-25 OO C1-10-2EX. C1-10-106 _ I I � I - -57 455 O O I I ) I � 1 I s9 1719 71 71 171 s l� 715 74 71 - I I - EX. C1-10-105 ® (9 ® � 0 CB -10-26 I O I 455- EX. CI -10-103 I RIM - 458.40 O \ - 171 � 135 , v \ \ V I I 721 EX. C1-10-104 I I I v� I I I O / _ I O _ \ II APPLY RECP ON SLOPES 3: 1 �� 460 O I i 440 - - EX. C1-11 X47 ( OR GREATER (TYP.) - - / A OO - 0-10-23 APPLY RECP ON SLOPES J.' 1 \ A I - I OR GREATER (TYP.) BMP #25 EX. C1-11-46 - - - - C170 I I i 72 - < \ �\ SEE DETAIL SHEETS D4.1 -D4.3 TEMPORARY CONSTRUCTION _ r-460 ENTRANCE (TYP.) _ - �� I 470 _ 465 _ I T A V - i w 72 z I I 1 1 C7( i I I \ \\\ \ \\ \ I I I - - s \ I \ - 7 72 72 / SDMH-10 236 145f w I - CB -10-23A O m -- I I I I I - - - RIM = 430.50 \\ \ C1-10-2 U a l I - - - _ _ - I A_ z I I HARDWARE CLOTH AND GRAVEL \ \ �� Z I I / I I 475 '^ \\ I I I INLET PROTECTION (TYP.) I / q o / Q m ( li 72 I / j 11 70 ` C7C 1)y �` I I I I \ ,� Cl -1 D-3 LJ N I ... ` - -. \ �J 00 v C1-10-28 I , - \ \ . 1 I. \ \ C1-10 -- -- -- - -- - - - -- -- ----- ---- ----- --- - --- -- _ � -- - - ---- --- -- -- - - --- T - - -- LIC RNN) -10-50 EX. C1-11-48 (QUARTER GATE TRACE (27' B -B, 40' PUB \ (2 ' B -B, 0' PU LIC R/ EX. C1-11-45 \ C1-10-15/ C1-10-14 C1-10-5 SDMH-10-51 III ci 10 27 I i _ H�-I 10-14D> MCI_ C1-10-17 144475 5 _ -7 Cl -0- APPLY RECP SLOPES 3.• 1 (D CF__OR GREATER (TYP.) z J -10-1877 7 6 III I III t/ - \ I II 0 I 5 2:, 1751 75 74 7 7 A 7 II 1 I C74) I I om I I I - - CB -10-14C 465 T 1470 I V C1-10-20 I I r RIM = 45254 �,I CB -10-14A >> -- _ I I / _ - �� CB45 ---10-14B RIM = 438. I � -- RIM 44397 ( RYE GRASS RUN TRAIL,\ - _ / I = - = 465 - 7 I I 73 = (15' E -E, 20' PRIVATE RAN) ✓ ¢6p 455 S(JrD I I _ _L� 7 Bi 0 \ / CB 10 30 I SKIMMER SEDIMENT BASIN #13 (INSTALLED IN STAGE 1 PER BRIAR I I I TDD #36 (INSTALLED IN STAGE 1 PER BRIAR CHAPEL SOUTH - w CLEARING AND GRUBBING PLANS') (TYP.) I ' l C1-10-29 I CHAPEL SOUTH CLEARING AND GRUBBING PLANS') (TYP.) I I I III _ - �73 �I - I AS AREA REACHES FINAL GRADES, CONTRACTOR IS TO REMOVE I 1 ' - of BASIN WITH APPROVAL FROM CHATHAM COUNTY 470 I I I ' I 17 \ I I I 71I z m 75 75 �` 7s - coMANN'S CHAPEL RD NORTH [V - SITE VICINITY MAP TO CHAPEL HILL NOT TO SCALE + TO PITTSBORO NPDES GROUNDCOVER STABILIZATION TIMEFRAMES SITE AREA STABILIZATION TIMEFRAME DESCRIPTION ENTRANCE EXCEPTIONS PERIMETER DIKES, 7 DAYS NONE SWALES, DITCHES, ADDITIONAL DISTURBED AREA UB C RNV) SLOPES N/A FENCE HIGH QUALITY WATER 7 DAYS NONE (HQW) ZONES EXISTING CONTOUR --- --- - SLOPES STEEPER 7 DAYS 14 DAYS FOR SLOPES THAN 3:1 NEW LIMITS OF DISTURBANCE 10' OR LESS IN SEDIMENT BASIN BAFFLE LENGTH AND NOT HARDWARE CLOTH & GRAVEL INLET PROT. STEEPER THAN 2:1 SLOPES 3:1 OR 14 DAYS 7 DAYS FOR SLOPES FLATTER TEMPORARY SLOPE DRAIN (INSTALLED IN STAGE 1 PER 'BRIAR GREATER THAN 50' IN SILT FENCE/TREE LENGTH ALL OTHER AREAS 14 DAYS NONE, EXCEPT FOR WITH SLOPES FLATTER PERIMETERS AND HQW THAN 4:1 ZONES A Lwo 77 1771 77 76 76 7 7 706 ii _ TDD# 38 ( INSTALLED IN STAGE 1 PER 'BRIAR CHAPEL SOUTH CLEARING AND GRUBBING PLANS) (TYP.) J��-460 C1-10-37.465 I I 75 / ! =- - -- -- -- -- J- - L--- -- L = =%---- --- -- ---- - h / AWK POI (27' B -B, 40' F MIR TDD #39 (INSTALLED IN STAGE 1 PER 'BRIAR CHAPEL SOUTH CLEARING AND GRUBBING PLANS) (TYP.) SEAL 1 ISSUED FOR PERMITTING 2015.12.04 REV. NO. DESCRIPTIONS DATE IL REVISIONS SEAL 4AL 036348 �.• 12/04/2015 : i-1 v vMFK1A4 & CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com I 111 - 1 I � , , I� AW PO OA � l (2T B 40 UBLI R/W) -10-12 RELOCATE SILT FENCE BRIAR CHAPEL 100' VIEWSHED BUFFER (TYP.) TO NEW LIMITS OF DISTURBANCE BRIAR U1, I CHAPEL V.7 Newland COMMUNITIES T {� \ SDMH-10 i� Ci/ -10-9 73 - C1-10-51: -7 - - - -- C1-10-5 4 - LIMITS OF DISTURBANCE SILT FENCE/TREE PROTECTION (TYP.) BRIAR CHAPEL PHASE 10 CHATHAM COUNTY, NORTH CAROLINA STAGE 2 GRADING, DRAINAGE & EROSION CONTROL PLAN EMERGENCY SPILL WA Y TO REMAIN WI THIN LIMI IS OF DISTURBANCE SKIMMER SEDIMENT BASIN #12 (INSTALLED IN STAGE 1 PER 'BRIAR CHAPEL SOUTH CLEARING AND GRUBBING PLANS) (TYP.) RIPRAP OUTLET PROTECTION SEE SHEET D 1.1 TDD #35 (INSTALLED IN STAGE 1 PER 'BRIAR CHAPEL SOUTH CLEARING AND GRUBBING PLANS) (TYP.) BRIAR CHAPEL 100' VIEWSHED BUFFER (TYP.) PERMITTED LIMITS OF DISTURBANCE (TYP.) LEGEND: MCE PROJ. # °°°°°°°°°°°°°°°° TEMPORARY CONSTRUCTION °°°°°°°°°°°°°°°° ENTRANCE BSS CHECKED N OAD - - 0 CHS ADDITIONAL DISTURBED AREA UB C RNV) COMBINATION SILT/TREE PROTECTION N/A FENCE TEMPORARY DIVERSION DITCH EXISTING CONTOUR --- --- - �- .=_ �_- ---- - -- fC 10-34 - -- - ---------------- - t------- _-------- NEW LIMITS OF DISTURBANCE - SEDIMENT BASIN BAFFLE HARDWARE CLOTH & GRAVEL INLET PROT. ARC PIPE INLET PROTECTION TEMPORARY SLOPE DRAIN (INSTALLED IN STAGE 1 PER 'BRIAR TDD #37 (INSTALLED IN STAGE 1 PER 'BRIAR CHAPEL SILT FENCE/TREE CHAPEL SOUTH CLEARING AND GRUBBING PLANS) (TYP.) SOUTH CLEARING AND GRUBBING PLANS) (TYP.) PROTECTION (TYP.) LIMITS OF DISTURBANCE SEAL 1 ISSUED FOR PERMITTING 2015.12.04 REV. NO. DESCRIPTIONS DATE IL REVISIONS SEAL 4AL 036348 �.• 12/04/2015 : i-1 v vMFK1A4 & CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com I 111 - 1 I � , , I� AW PO OA � l (2T B 40 UBLI R/W) -10-12 RELOCATE SILT FENCE BRIAR CHAPEL 100' VIEWSHED BUFFER (TYP.) TO NEW LIMITS OF DISTURBANCE BRIAR U1, I CHAPEL V.7 Newland COMMUNITIES T {� \ SDMH-10 i� Ci/ -10-9 73 - C1-10-51: -7 - - - -- C1-10-5 4 - LIMITS OF DISTURBANCE SILT FENCE/TREE PROTECTION (TYP.) BRIAR CHAPEL PHASE 10 CHATHAM COUNTY, NORTH CAROLINA STAGE 2 GRADING, DRAINAGE & EROSION CONTROL PLAN EMERGENCY SPILL WA Y TO REMAIN WI THIN LIMI IS OF DISTURBANCE SKIMMER SEDIMENT BASIN #12 (INSTALLED IN STAGE 1 PER 'BRIAR CHAPEL SOUTH CLEARING AND GRUBBING PLANS) (TYP.) RIPRAP OUTLET PROTECTION SEE SHEET D 1.1 TDD #35 (INSTALLED IN STAGE 1 PER 'BRIAR CHAPEL SOUTH CLEARING AND GRUBBING PLANS) (TYP.) BRIAR CHAPEL 100' VIEWSHED BUFFER (TYP.) PERMITTED LIMITS OF DISTURBANCE (TYP.) LEGEND: MCE PROJ. # °°°°°°°°°°°°°°°° TEMPORARY CONSTRUCTION °°°°°°°°°°°°°°°° ENTRANCE BSS CHECKED RIPRAP OUTLET PROTECTION PROJ. MGR. CHS ADDITIONAL DISTURBED AREA SF/TPF COMBINATION SILT/TREE PROTECTION N/A FENCE TEMPORARY DIVERSION DITCH EXISTING CONTOUR 535 PROPOSED CONTOUR EX. LIMITS OF DISTURBANCE NEW LIMITS OF DISTURBANCE - SEDIMENT BASIN BAFFLE HARDWARE CLOTH & GRAVEL INLET PROT. ARC PIPE INLET PROTECTION CHECK DAM CALL N.C. ONE CALL CENTER BEFORE YOU DIG STOP 1-800-632-4949 AVOID UTILITY \ DAMAGE NORTH 50' 0 50' 100' SCALE: 1"=50' (Horiz.) DATE: DECEMBER 4, 2015 MCE PROJ. # 02735-0151 DRAWN BSS DESIGNED BSS CHECKED GCA PROJ. MGR. CHS C3.2 SCALE M&C FILE NUMBER C3.X HORIZONTAL' DRAWING NUMBER 1" = 50' VERTICAL: C3.2 N/A STATUS: FINAL DRAWINGS REVISION ,FOR REVIEW PURPOSES ONLY 1 , 470 CHATHAM COUNTY � \ 10' NO -BUILD BUFFER ENDWALL PER NCDOT DETAIL 838.80 FOR 24" PIPE CHA THAM I COUNT BUFFER INV OUT. 411.00 \\\ \ \ FIL TER DIAPHRAM SEE DETAIL SHEET D4.2 IN, 1 I IN, `tK 4/1 iC -ems � t.N EX. HW -10-100 j \ INV.=414.67 / CLASS 1 RIPRAP PLACED AT \ENDWALL PER NCDOT DETAIL SEDIMENT FOREBAY �� 46.8 LF 24" 419 24" DEPTH WITH SUBLAYER 838.80 FOR 30" PIPE �✓ BOTTOM EL. 408.0' - CONCRETE PRESSURE PIPE \ I OF 6" FS -2 FILTER STONE LINING � 4j9 \ INSTALLED TO DIMENSIONS SHOWN. L PRINCIPLE SPILLWAY SEE DETAILS THIS SHEET I � s BF O. \ BMP 1124 NORMAL POOL EL. 413.5' \� \ BOTTOM OF POND EL. 406.0' I ` RIPRAP OUTLET \ \ \ \ PROTECTION. SEE �\ \ DETAIL SHEET D1.2 \ PROTECT 3-PHASE \ \� \ E ELECTRIC TO I 475! PROPERTY BOUNDARY \ REMAIN \ I 10.0' D \ AM WID TH J. . a V EMERGENCY SPILLWAY SEE DETAIL SHEET D4.2 NO CONCRETE SURFACES SHALL BE \ \�1 WITHIN ' ° HW -10-1 VEGETA TED VIEWSHED BUFFER INV. = 414.00 SHELF \ ENDWALL PER NCDOT DETAIL 1\` 838.80 FOR 30" PIPE \\ , �_ I 3: 1 BRIAR CHAPEL �� 10 I I VIEWSHED BUFFER oma 3: 1 I RIPRAP OUTLET (j) PROTECTION. SEE ` RIPRAP OUTLET ' /� DETAIL SHEET D1.2 �1 PROTECTION. SEE / -- DETAIL SHEET D1.2 I� I` HW -10-50 Ilk INV.=414.00 SEDIMENT FOREBAY ENDWALL PER NCDOT DETAIL S J I 1 II BOTTOM EL. 408.0' \ 838.80 FOR 15" PIPE I I \\ 1 I _ 420 i \ I NORTH WET DETENTION POND #25 PLAN VI EW SCALE = 1 " = 30' GALVANIZED 3.5'x3.5'x3/16" TRASH RACK PRECAST CONCRETE BOX 0.75' EACH SIDE 24" CONCRETE-/ PRESSURE PIPE INV.= 411.50' SECTION VIEW TOP EL.=415.10' 6.0" LOW FLOW ORIFICE EL. 413.50' WITH TURNED -DOWN PVC ELBOW WITH 3.00" HOLE DRILLED IN CAP FILL WITH GROUT BOTTOM EL.=411.00' ANGLE IRONS: 4" X 4" X 5/8" X 4' LONG TYPICAL EACH SIDE FASTENERS: 1" 0 EXPANSION ANCHORS 8" 0. C. PLACE CEMENT MORTAR CONCRETE PRESSURE PIPE JOINT DETAIL SECTION AT PRINCIPLE SPILLWAY SEAL 036348 •• 12/04/2015 ; 1 ISSUED FOR PERMITTING 2015.12.04 REV. NO. DESCRIPTIONS DATE REVISIONS SCALE = 1 " = 4' A vMFMM&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com NTS 3Y4"LAP 1" b P-\/QAr\IQ .,1 . ANCHORS TYPICAL EACH SIDE PRINCIPLE SPILLWAY SCALE = 1 " = 2' PLACE CEMENT MORTAR IN JOINT SPACE SECTION H MAINTAIN MIN. 1' OF COVER OVER PIPE CONCRETE ENDWALL PER NCDOT STANDARD 838.80 EL. 411.0'RIPRAP OUTLET PROTECTION. SEE DETAIL THIS SHEET BRIAR7SKCHAPEL' L.. Y -Y Newlan i COMMUNITIES PLAN VIEW - IRON 4" X 5/8" X 3' LONG TYPICAL EACH SIDE 24 -IN RCP PRESSURE PIPE SELECT FILL PLACED AND COMPACTED AT 95% STANDARD PROCTOR MAX 12" DRY DENSITY AT PLUS 2%-3% OF �MIN)� OPTIMUM MOISTURE CONTENT TO TOP OF PIPE II 15.0" i a L 12" (MIN)-� SELECT FILL PLACED AND COMPACTED AT 95� STANDARD PROCTOR MAX DRY DENSITY AT OPTIMUM TO PLUS 3% OF CONCRETE CRADLE OPTIMUM MOISTURE CONTENT TO MIDPOINT (MIN 2000 PSI CONCRETE) OF PIPE PRIOR TO TRENCH EXCAVATION CONCRETE CRADLE DETAIL NTS CP 0 O(22J�� A �0C� 00� 0 A FLOW o�Q� DoOo� o� O� W D�H OF ENDWALL (WHICHEVER OOOOO� IS GREATER) ooc�o PLAN VIEW CONCRETE ENDWALL FOR 24" PIPE PER NCDOT DETAIL 838.80 NCDOT CLASS 1 RIPRAP FLOW - 16' T 6" FS -2 FILTER STONE SECTION A -A RIPRAP 0 UTLET PROTECTION BRIAR CHAPEL PHASE 10 CHATHAM COUNTY, NORTH CAROLINA BMP #25 PLAN & DETAILS NTS DATE: DECEMBER 4, 2015 10.0' # 02735-0151 DRAWN 28.3' 8.3' 12.0' CHECKED GCA PROJ. MGR. CHS TOP OF BANK � 3 EL. 419.00' � 100 -YR, 24 -HR STORM EL. 417.85' 1 � 1 10 -YR, 24 -HR STORM EL. 416.83' - - - - - - -EMERGENCY SPILLWAY EL_ 417.00'- ------2, 1 -YR, 24 -HR STORM EL. 415.49' FILTER DIAPHRAGM MAINTAIN MIN. 1' OF SEE DETAIL SHEET D-4.2 COVER OVER PIPE 2' NORMAL POOL EL. 413.50' _ --------------------------------- 46.8 LINEAR LINEAR FEET - 24" CONCRETE PRESSURE PIPE -- d 4 a d d Q d- a -----s a--+�-d-- G- Q _ d ®1 d EL. 411.50' 2' PRINCIPLE SPILLWAY CONCRETE CRADLE TO RUN BOTTOM OF POND SEE DETAIL THIS SHEET LENGTH OF PIPE NOTE: SEE DAM EMBANKMENT 6" PVC TO DAYLIGHT EL. 406.0' SEE DETAIL THIS SHEET DETAIL (SHEET 04.2) SECTION AT PRINCIPLE SPILLWAY SEAL 036348 •• 12/04/2015 ; 1 ISSUED FOR PERMITTING 2015.12.04 REV. NO. DESCRIPTIONS DATE REVISIONS SCALE = 1 " = 4' A vMFMM&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com NTS 3Y4"LAP 1" b P-\/QAr\IQ .,1 . ANCHORS TYPICAL EACH SIDE PRINCIPLE SPILLWAY SCALE = 1 " = 2' PLACE CEMENT MORTAR IN JOINT SPACE SECTION H MAINTAIN MIN. 1' OF COVER OVER PIPE CONCRETE ENDWALL PER NCDOT STANDARD 838.80 EL. 411.0'RIPRAP OUTLET PROTECTION. SEE DETAIL THIS SHEET BRIAR7SKCHAPEL' L.. Y -Y Newlan i COMMUNITIES PLAN VIEW - IRON 4" X 5/8" X 3' LONG TYPICAL EACH SIDE 24 -IN RCP PRESSURE PIPE SELECT FILL PLACED AND COMPACTED AT 95% STANDARD PROCTOR MAX 12" DRY DENSITY AT PLUS 2%-3% OF �MIN)� OPTIMUM MOISTURE CONTENT TO TOP OF PIPE II 15.0" i a L 12" (MIN)-� SELECT FILL PLACED AND COMPACTED AT 95� STANDARD PROCTOR MAX DRY DENSITY AT OPTIMUM TO PLUS 3% OF CONCRETE CRADLE OPTIMUM MOISTURE CONTENT TO MIDPOINT (MIN 2000 PSI CONCRETE) OF PIPE PRIOR TO TRENCH EXCAVATION CONCRETE CRADLE DETAIL NTS CP 0 O(22J�� A �0C� 00� 0 A FLOW o�Q� DoOo� o� O� W D�H OF ENDWALL (WHICHEVER OOOOO� IS GREATER) ooc�o PLAN VIEW CONCRETE ENDWALL FOR 24" PIPE PER NCDOT DETAIL 838.80 NCDOT CLASS 1 RIPRAP FLOW - 16' T 6" FS -2 FILTER STONE SECTION A -A RIPRAP 0 UTLET PROTECTION BRIAR CHAPEL PHASE 10 CHATHAM COUNTY, NORTH CAROLINA BMP #25 PLAN & DETAILS NTS DATE: DECEMBER 4, 2015 VICE PROD. # 02735-0151 DRAWN BSS DESIGNED BSS CHECKED GCA PROJ. MGR. CHS SCALE M&C FILE NUMBER D4.X HORIZONTAL: DRAWING NUMBER AS NOTED VERTICAL: D4.1 N/A 'STATUS: FINAL DRAWINGS REVISION ,FOR REVIEW PURPOSES ONLY 1 , TOP OF DAM 3.0 W1.4xW1.4 6X6 W.W.M. OR APPROVED EQUAL (MIN 2" COVER) 6" THICK CONCRETE 3000 psi © 28 DAYS NORMAL POOL SPILLWAY SHOULD7 EXTEND TO NORMAL POOL ELEVATION ON BMP SIDE I NIS SNt� I SPILLWAY BOTTOM WIDTH SEE TABLE THIS SHEET SECTION A—A VARIES VARIES EFER T PLAN �r �-1 -ir _I II— W1.4xW1.4 6X6 W.W.M. OR APPROVED EQUAL (MIN 2" COVER) SECTION B—B VARIES .0 (MIN.) 11.4111 EMERGENCY SPILLWAY DETAIL. NTS 1 ISSUED FOR PERMITTING 2015.12.04 REV. NO. DESCRIPTIONS DATE 6" THICK CONCRETE 3000 psi @ 28 DAYS TOP OF SPILLWAY SPILLWAY SHALL EXTEND TO BOTTOM OF FILL SLOPE ON Ed — DOWNSTREAM SIDE 11- NOTE: EXPANSION/CONTRACTION JOINTS PER AMERICAN CONCRETE INSTITUTE (ACI) STANDARDS FOR SLABS ON GRADE. SEAL 1 SEAL �-\N.......... iE ss/O,y9 4AL 036348 •• 12/04/2015 ; FT •........ PJ 8' KEY TRENCH DAM EMBANKMENT DETAIL NTS 2' #57 WASHED STONE 6" SOLID WALL PVC TO DAYLIGHT LIMITS OF ° VARMINT SCREEN TO CONCRETE CRADLE12..75' ° BE PLACED ON OPENEND. ° FLS $ ° 24" CONCRETE ° PRESSURE PIPE ° 0 ° 2.75' ° 06" SOLID WALL PVC LIMITS OF4-1 o TO DAYLIGHT CONCRETE CRADLE VARMINT SCREEN TO BE PLACED ON OPENEND. 6" PERFORATED PVC COLLECTOR PIPE TO BE COLLECTOR PIPE CAPPED ON BOTH ENDS PLAN VIEW 3' 2' PROPOSED GRADE ON DOWNSTREAM SIDE OF DAM 2' MIN. #57 WASHED STONE I T 2, FLOW 6 1.5' MIRAFI 140N GEOSYNTHETIC FABRIC WITH 18 -INCH OVERLAP AT ALL SEAMS (TYP) 24" CONCRETE PRESSURE PIPE 6" SOLID WALL PVC TO DAYLIGHT VARMINT SCREEN TO BE PLACED ON OPEN END. SECTION VIEW FILTER DIAPHRAGM DETAIL NTS v v &CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com DAM EMBANKMENT NOTES: 1) TOPSOIL BENEATH THE EMBANKMENT SHALL BE REMOVED AND STOCKPILED. THE FOUNDATION WILL BE PROOF ROLLED AND ANY SOFT OR ORGANIC MATERIALS WILL BE REMOVED. 2) ALL MATERIAL SHALL BE COMPACTED IN 6-8 INCH LIFTS TO 95% OF MAXIMUM STANDARD PROCTOR DRY DENSITY OR HIGHER (ASTM D-698). THE CLAY CORE ZONE WILL HAVE A MOISTURE CONTENT OF OPTIMUM TO 4 PERCENT ABOVE OPTIMUM MOISTURE CONTENT. THE SHELL ZONE FILL WILL HAVE A MOISTURE CONTENT FROM 2 PERCENT BELOW OPTIMUM MOISTURE CONTENT TO 4 PERCENT ABOVE OPTIMUM. 3) EMBANKMENT FILL: SHELL ZONE: SOILS WITH LESS THAN 30% PASSING THE NO. 200 SIEVE OR A PI OF LESS THAN 10 WHEN THE PERCENTAGE OF MATERIAL PASSING THE NO. 200 SIEVE IS GREATER THAN 30 PERCENT. SOILS WHICH ARE CLASSIFIED AS CLAYS (CH OR CL) SHOULD NOT BE USED AT THE FACE OF THE SHELL ZONES. CLAY CORE ZONE: CH, CL OR SC MATERIAL WITH A PI RANGING BETWEEN 15 AND 60 4) NO FILL SHALL CONTAIN ROCKS OR GRAVEL LARGER THAN 4 INCHES IN DIAMETER. 5) A PROFESSIONAL GEOTECHNICAL ENGINEER SHALL APPROVE ALL MATERIALS USED FOR THE EMBANKMENT AND SUPERVISE CONSTRUCTION. 6) ALL DISTURBED AREAS ABOVE PERMANENT POOL SHALL BE SEEDED USING THE FOLLOWING GRASS SEED MIX MANUFACTURED BY ERNST SEED COMPANY: Carolina FACW Meadow Mix ERNMX-182 -n m 'a m o M 0 m 0 V! _ N 0 C7 D _ � Z C > N m v =-v _ M m m H Z z Sao m r W1 (FT.) ELEVATION 17 H2 H1 I.C.(TYP.) �R TO CHART FOR BAR SIZE BRIAR7SKCHAPEL' by Newland COMMUNITIES PLAN 1 D 6" V-0" 0 I I H1 I — 8"II O.C.(TYP.) L REFER TO CHART FOR BAR SIZE CLAY LINER NOTES: EXISTING GROUND IN ORDER TO HELP SUSTAIN THE PERMANENT POOL AND TO PREVENT WATER FROM INFILTRATING TOO QUICKLY INTO THE UNDERLYING SOIL, THE CONTRACTOR SHALL INSTALL A 6" THICK CLAY LINER ON THE BOTTOM OF THE BMP AREA UP TO THE NORMAL POOL ELEVATION. THE LINER CAN BE ACCOMPLISHED BY BLENDING EXISTING SITE SOILS WITH CLAY TO ACHIEVE A LOW PERMEABILITY MIXTURE OR BY INSTALLING A GEOSYNTHETIC LINER MADE OF A BENTOMAT CL. IF THE CONTRACTOR CHOOSES TO BLEND THE EXISTING SITE SOILS WITH CLAY, THE ONSITE GEOTECHNICAL ENGINEER SHALL DETERMINE THE AMOUNT OF CLAY TO ADD, THE DEGREE OF COMPACTION, AND WILL OVERSEE THE INSTALLATION OF THE CLAY LINER. THE MAXIMUM PERMEABILITY RATE FOR THE LINER SHALL BE 0.01 IN/HR IN ACCORDANCE WITH THE NCDENR BMP MANUAL. THE PROPOSED MATERIAL FOR THIS LINER SHALL BE TESTED BY THE ONSITE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT. THE RESULTS OF THIS TESTING SHALL BE SUBMITTED TO THE DESIGN ENGINEER FOR REVIEW PRIOR TO PLACEMENT. UPON COMPLETION OF LINER INSTALLATION, A 4" MINIMIMUM LAYER OF TOPSOIL SHALL BE ADDED OVER THE LINER TO PROVIDE A HEALTHY MEDIA FOR VEGETATION GROWTH. NOTES: * THIS PRECAST ENDWALL MAY BE USED FOR THE FOLLOWING STANDARDS: 838.01, 838.11, 838.21, 838.27, 838.33, 838.39, 838.51, 838.57, 838.63 AND 838.69. * INSTALL PRECAST ENDWALLS WITH WINGS AND PAY FOR IN ACCORDANCE WITH SPECIFICATION SECTION 838. * USE 4000 PSI CONCRETE. * PROVIDE ALL REINFORCING STEEL WHICH MEETS ASTM A615 FOR GRADE 60 AND WELDED WIRE FABRIC CONFORMING TO ASTM A185 WITH 2" MIN. CLEARANCE. * PLACE LIFT HOLES OR PINS IN ACCORDANCE WITH OSHA STANDARD 1926.704. * PIPE TO BE GROUTED INTO HEADWALL AT JOB SITE BY CONTRACTOR * ALL ELEMENTS PRECAST TO MEET ASTM C913. * WELDED WIRE FABRIC MAY BE SUBSTITUTED FOR REBAR AS LONG AS THE SAME AREA OF STEEL IS PROVIDED. * CHAMFER ALL CORNERS 1" OR HAVE A RADIUS OF 1" NOTE: THEMINIMUM BAR SIZE SHALL BE #5 BARS AT B" CTS. THE CONTRACTOR WILL HAVE THE OPTION TO INCREASE THIS BAR SIZE AS NEEDED. NORMAL TOP DAM SPILLWAY SPILLWAY BSS POOL EL' BOTTOM BOTTOM MIN./MAX. EL. MIN./MAX. EL. WIDTH BMP #25 413.50 419.00 417.00 20' EMERGENCY SPILLWAY DETAIL. NTS 1 ISSUED FOR PERMITTING 2015.12.04 REV. NO. DESCRIPTIONS DATE 6" THICK CONCRETE 3000 psi @ 28 DAYS TOP OF SPILLWAY SPILLWAY SHALL EXTEND TO BOTTOM OF FILL SLOPE ON Ed — DOWNSTREAM SIDE 11- NOTE: EXPANSION/CONTRACTION JOINTS PER AMERICAN CONCRETE INSTITUTE (ACI) STANDARDS FOR SLABS ON GRADE. SEAL 1 SEAL �-\N.......... iE ss/O,y9 4AL 036348 •• 12/04/2015 ; FT •........ PJ 8' KEY TRENCH DAM EMBANKMENT DETAIL NTS 2' #57 WASHED STONE 6" SOLID WALL PVC TO DAYLIGHT LIMITS OF ° VARMINT SCREEN TO CONCRETE CRADLE12..75' ° BE PLACED ON OPENEND. ° FLS $ ° 24" CONCRETE ° PRESSURE PIPE ° 0 ° 2.75' ° 06" SOLID WALL PVC LIMITS OF4-1 o TO DAYLIGHT CONCRETE CRADLE VARMINT SCREEN TO BE PLACED ON OPENEND. 6" PERFORATED PVC COLLECTOR PIPE TO BE COLLECTOR PIPE CAPPED ON BOTH ENDS PLAN VIEW 3' 2' PROPOSED GRADE ON DOWNSTREAM SIDE OF DAM 2' MIN. #57 WASHED STONE I T 2, FLOW 6 1.5' MIRAFI 140N GEOSYNTHETIC FABRIC WITH 18 -INCH OVERLAP AT ALL SEAMS (TYP) 24" CONCRETE PRESSURE PIPE 6" SOLID WALL PVC TO DAYLIGHT VARMINT SCREEN TO BE PLACED ON OPEN END. SECTION VIEW FILTER DIAPHRAGM DETAIL NTS v v &CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com DAM EMBANKMENT NOTES: 1) TOPSOIL BENEATH THE EMBANKMENT SHALL BE REMOVED AND STOCKPILED. THE FOUNDATION WILL BE PROOF ROLLED AND ANY SOFT OR ORGANIC MATERIALS WILL BE REMOVED. 2) ALL MATERIAL SHALL BE COMPACTED IN 6-8 INCH LIFTS TO 95% OF MAXIMUM STANDARD PROCTOR DRY DENSITY OR HIGHER (ASTM D-698). THE CLAY CORE ZONE WILL HAVE A MOISTURE CONTENT OF OPTIMUM TO 4 PERCENT ABOVE OPTIMUM MOISTURE CONTENT. THE SHELL ZONE FILL WILL HAVE A MOISTURE CONTENT FROM 2 PERCENT BELOW OPTIMUM MOISTURE CONTENT TO 4 PERCENT ABOVE OPTIMUM. 3) EMBANKMENT FILL: SHELL ZONE: SOILS WITH LESS THAN 30% PASSING THE NO. 200 SIEVE OR A PI OF LESS THAN 10 WHEN THE PERCENTAGE OF MATERIAL PASSING THE NO. 200 SIEVE IS GREATER THAN 30 PERCENT. SOILS WHICH ARE CLASSIFIED AS CLAYS (CH OR CL) SHOULD NOT BE USED AT THE FACE OF THE SHELL ZONES. CLAY CORE ZONE: CH, CL OR SC MATERIAL WITH A PI RANGING BETWEEN 15 AND 60 4) NO FILL SHALL CONTAIN ROCKS OR GRAVEL LARGER THAN 4 INCHES IN DIAMETER. 5) A PROFESSIONAL GEOTECHNICAL ENGINEER SHALL APPROVE ALL MATERIALS USED FOR THE EMBANKMENT AND SUPERVISE CONSTRUCTION. 6) ALL DISTURBED AREAS ABOVE PERMANENT POOL SHALL BE SEEDED USING THE FOLLOWING GRASS SEED MIX MANUFACTURED BY ERNST SEED COMPANY: Carolina FACW Meadow Mix ERNMX-182 -n m 'a m o M 0 m 0 V! _ N 0 C7 D _ � Z C > N m v =-v _ M m m H Z z Sao m r W1 (FT.) ELEVATION 17 H2 H1 I.C.(TYP.) �R TO CHART FOR BAR SIZE BRIAR7SKCHAPEL' by Newland COMMUNITIES PLAN 1 D 6" V-0" 0 I I H1 I — 8"II O.C.(TYP.) L REFER TO CHART FOR BAR SIZE CLAY LINER NOTES: EXISTING GROUND IN ORDER TO HELP SUSTAIN THE PERMANENT POOL AND TO PREVENT WATER FROM INFILTRATING TOO QUICKLY INTO THE UNDERLYING SOIL, THE CONTRACTOR SHALL INSTALL A 6" THICK CLAY LINER ON THE BOTTOM OF THE BMP AREA UP TO THE NORMAL POOL ELEVATION. THE LINER CAN BE ACCOMPLISHED BY BLENDING EXISTING SITE SOILS WITH CLAY TO ACHIEVE A LOW PERMEABILITY MIXTURE OR BY INSTALLING A GEOSYNTHETIC LINER MADE OF A BENTOMAT CL. IF THE CONTRACTOR CHOOSES TO BLEND THE EXISTING SITE SOILS WITH CLAY, THE ONSITE GEOTECHNICAL ENGINEER SHALL DETERMINE THE AMOUNT OF CLAY TO ADD, THE DEGREE OF COMPACTION, AND WILL OVERSEE THE INSTALLATION OF THE CLAY LINER. THE MAXIMUM PERMEABILITY RATE FOR THE LINER SHALL BE 0.01 IN/HR IN ACCORDANCE WITH THE NCDENR BMP MANUAL. THE PROPOSED MATERIAL FOR THIS LINER SHALL BE TESTED BY THE ONSITE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT. THE RESULTS OF THIS TESTING SHALL BE SUBMITTED TO THE DESIGN ENGINEER FOR REVIEW PRIOR TO PLACEMENT. UPON COMPLETION OF LINER INSTALLATION, A 4" MINIMIMUM LAYER OF TOPSOIL SHALL BE ADDED OVER THE LINER TO PROVIDE A HEALTHY MEDIA FOR VEGETATION GROWTH. NOTES: * THIS PRECAST ENDWALL MAY BE USED FOR THE FOLLOWING STANDARDS: 838.01, 838.11, 838.21, 838.27, 838.33, 838.39, 838.51, 838.57, 838.63 AND 838.69. * INSTALL PRECAST ENDWALLS WITH WINGS AND PAY FOR IN ACCORDANCE WITH SPECIFICATION SECTION 838. * USE 4000 PSI CONCRETE. * PROVIDE ALL REINFORCING STEEL WHICH MEETS ASTM A615 FOR GRADE 60 AND WELDED WIRE FABRIC CONFORMING TO ASTM A185 WITH 2" MIN. CLEARANCE. * PLACE LIFT HOLES OR PINS IN ACCORDANCE WITH OSHA STANDARD 1926.704. * PIPE TO BE GROUTED INTO HEADWALL AT JOB SITE BY CONTRACTOR * ALL ELEMENTS PRECAST TO MEET ASTM C913. * WELDED WIRE FABRIC MAY BE SUBSTITUTED FOR REBAR AS LONG AS THE SAME AREA OF STEEL IS PROVIDED. * CHAMFER ALL CORNERS 1" OR HAVE A RADIUS OF 1" NOTE: THEMINIMUM BAR SIZE SHALL BE #5 BARS AT B" CTS. THE CONTRACTOR WILL HAVE THE OPTION TO INCREASE THIS BAR SIZE AS NEEDED. BRIAR CHAPEL PHASE 10 CHATHAM COUNTY, NORTH CAROLINA BMP #25 PLAN & DETAILS DATE: DECEMBER 4, 2015 VICE PROD. ENDWALL DIMENSIONS DRAWN BSS DESIGNED FT. MINIMUM MIN./MAX. MIN./MAX. MIN./MAX. MIN./MAX. MIN./MAX. PIPE DIA. BAR SIZE H1(FT.) H2(FT.) D (FT.) W1 W2 1.0 #5 @ B" 1.25/2.00 2.00/3.75 1.25/1.75 3.00/3.75 5.50/6.00 1.25 #5 @ 8" 1.25/2.00 3.00/3.75 1.25/2.00 3.50/3.75 6.50/6.75 1.50 #5 @ 8" 1.25/2.00 3.00/4.25 1.50/2.50 3.50/3.75 6.50/6.75 2.0#5 @ 8" 1.50/2.50 4.00/4.75 1.75/2.50 4.00/4.25 7.50/8.25 2.5 #5 @ B" 2.50/3.50 4.00/6.00 2.00/3.00 4.50/5.50 10.00/11.50 3.0 #5 @ 8" 3.00/3.50 5.00/6.00 2.75/3.50 5.25/5.75 11.50/11.75 3.5 #5 @ 8" 3.25/4.50 6.00/6.75 3.25/3.50 6.00/6.75 12.00/13.25 4.0 #5 @ 8" 3.50/4.50 6.50/7.00 3.25/3.50 6.50/6.75 13.00/13.25 4.5 #5 @ 8" 4.00/5.00 6.50/8.50 3.25/4.00 7.00/9.25 13.50/15.75 5.0 #5 @ 8" 4.50/5.00 7.00/8.50 3.25/4.00 7.25/9.25 13.75/15.75 5.5 #5 @ B" 4.50/5.00 7.50/8.50 3.25/4.00 7.25/9.25 14.00/15.75 6.0 #5 @ B" 4.50/5.00 7.50/8.50 3.25/4.00 7.75/9.25 14.75/16.75 BRIAR CHAPEL PHASE 10 CHATHAM COUNTY, NORTH CAROLINA BMP #25 PLAN & DETAILS DATE: DECEMBER 4, 2015 VICE PROD. # 02735-0151 DRAWN BSS DESIGNED BSS CHECKED GCA PROJ. MGR. CHS z 065 as Hp~COU U- -i z 0065= Z a01= 1-4 cnH�OJ 00U) 1 LU � Q0 LU J Y C:) J o U-4° 0 0 0) Q W a N 0 LU a 0 ~N Q � � z Z = < O� 65 N = H T cn y1--4 Oct w C-1)CD 0 VM LU N W 0 LL SCALE HORIZONTAL: AS NOTED VERTICAL: N/A M&C FILE NUMBER D4.X DRAWING NUMBER D4.2 STATUS: FINAL DRAWINGS REVISION FOR REVIEW PURPOSES ONLY � 21 CF / I/ O26 JPW 4� � � I WET DETENTION POND #25 PLANTING PLAN SCALE = 1 " = 20' SEAL 1 1 ISSUED FOR PERMITTING 2015.12.04 REV. NO. DESCRIPTIONS DATE 16. REVISIONS SEAL / ��N.... CARO�,11 `��`` ��Q�pEESS/O,y9 •. by ''��; 036348 •• 12/04/2015 ; ��'%9�•' FNGINEER..•••.P�\\�� /y 111111 A vNlqQW&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919)233-8091, Fax: (919)233-8031 F-1222 www.mckimcreed.com PLANTING SCHEDULE DECEMBER 4, 2015 MCE PROD. # 02735-0151 DRAWN BSS DESIGNED CONTAINER SIZE AT SYM. ABB. COMMON NAME BOTANICAL NAME QUANTITY SPACING PLANTING SHALLOW WATER PLANTINGS Lvx LVA SF SWEETFLAG Acorus subcordatum 105 24"-30" O.C. 1 QT. PW PICKERELWEED Pontederia cordato 103 24"-30" O.C. 1 QT. ------ MR BFI BLUE FLAG IRIS Iris virginica 110 24"-30" O.C. 1 QT. +++++ SR SOFT RUSH Juncus effusus var. 103 24"-30" O.C. 1 QT. pylaei or solutus v� v TSB THREE SQUARE BULRUSH Schoenoplectus 103 24"-30" O.C. 1 QT. v v v americanus SHALLOW LAND PLANTINGS LLLL :LLLLL SM SWAMP MILKWEED Asclepias incarnate 110 24"-30" O.C. 1 QT. LLLL CF CARDINAL FLOWER Lobelia cardinalis 105 24"-30" O.C. 1 QT. SRM SCARLET ROSE MALLOW Hibiscus coccineus 112 24"-30" O.C. 1 QT. JPW DWARF JOE PYE WEED Eupatoriadelphus dubius 110 24"-30" O.C. 1 QT. ST SPOTTED TRUMPETWEED Eupatoriadelphus 106 24"-30" O.C. 1 QT. maculatus CUT & REMOVE ANY COVERING AROUND ROOTS INSTALL PLANTS WHERE CROWN IS FLUSH WITH SOIL SURFACE AMENDED TOPSOIL MIN. 12 IN DEPTH + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + . + + + + + + + + + + + + + + + + + + + + + + + + ill=1 11=1 11=L I I �I 11=1 11=J 11=1 I I- Li I I 1=l -_ TWICE ROOT DIAMETER I EXISTING SOIL f 1 GENERAL PLANTING DETAIL NTS EACH VARIETY OF PLANT NOTED TO BE PLANTED SHALL BE IN GROUPS AS SHOWN ON THIS SHEET. SHALLOW WATER PLANT VARIETY 'A' - - - /r. - NORMAL POOL LEVEL 0- C)0 U 0 0404 SHALLOW LAND / PLANT VARIETY 'A' 10 24" D.C. (TYP) LIMITS OF 10:1 SHELF SHALLOW WATER PLANT VARIETY 'B' SHALLOW LAND PLANT VARIETY 'B' NOTES: 1. CONTINUE PLANTING SCHEME SHOWN FOR EACH OF THE 5 PLANT VARIETIES NOTED BELOW AROUND 0 ENTIRE LENGTH OF THE SHALLOW WATER PLANTING ZONE 2. CONTINUE PLANTING SCHEME SHOWN FOR EACH OF THE 5 PLANT VARIETIES NOTED BELOW AROUND ENTIRE LENGTH OF THE SHALLOW LAND PLANTING 0 ZONE 3. OTHER SPECIES WITH SIMILAR GROWTH HABITS AND MAY BE APPROVED AS LISTED IN THE "STORMWATER BEST MANAGEMENT PRACTICES MANUAL" TABLE 9-1. VEGETATED PLANTING SHELF DETAIL NTS GENERAL PLANTING NOTES: 1. AVOID COMPACTING TOPSOIL TO PROMOTE HEALTHY ENVIRONMENTAL CONDITIONS FOR THE PLANTS. 2. ALL PLANTS SHOULD BE PLANTED IN THE INDICATED RANGE TO ENSURE SURVIVAL. 3. SHALLOW WATER AND SHALLOW LAND AREAS TO BE PLANTED WITH BARE ROOT, PLUGS, OR CONTAINER LIVE PLANTINGS AS SPECIFIED. 4. EXCAVATE A HOLE TWICE THE DIAMETER OF ROOT BALL AND EQUAL TO THE ROOT DEPTH OF THE INDIVIDUAL PLANT. PLACE PLANT IN HOLE WITH CROWN FLUSH WITH SOIL SURFACE. BACKFILL WITH TOPSOIL AND LIGHTLY PLANT. 5. BEGIN PLANTING DURING LOCAL GROWING SEASON IN ORDER TO ENSURE THAT PLANTS HAVE ADEQUATE TIME TO ESTABLISH BEFORE WINTER MONTHS. 6. OBTAIN PLANTS FROM: COASTAL PLAIN CONSERVATION NURSERY (252-482-5707), MELLOW MARSH FARMS (919-742-1200), CURE NURSERY (919-542-6186) OR ENGINEER APPROVED SUBSTITUTE. 7. REFER TO EROSION CONTROL DETAIL SHEET D1.2 FOR SEEDBED PREPARATION AND SEEDING SCHEDULES FOR AREAS NOT SPECIFIED IN THIS PLAN. SHALLOW WATER PLANTING NOTES: 1. 70% OF PICKERELWEED SHOULD BE PLANTED WITHIN 5-6 INCHES BELOW NORMAL POOL. 2. 70% OF SWEETFLAG AND 70% OF SOUTHERN BLUE FLAG IRIS SHOULD BE PLANTED IN THE 2-3 INCHES BELOW NORMAL POOL. 3. 70% OF SOFT RUSH SHOULD BE PLANTED AT THE NORMAL POOL ELEVATION. SHALLOW LAND PLANTING NOTES: 1. PLANTS IN THIS GROUP SHOULD NOT BE PLANTED IN AREAS THAT ARE INUNDATED FOR EXTENDED PERIODS. BRIARrSKCHAPEL' by Newland COMMUNITIES BRIAR CHAPEL PHASE 10 CHATHAM COUNTY, NORTH CAROLINA BMP #25 PLAN & DETAILS DATE: DECEMBER 4, 2015 MCE PROD. # 02735-0151 DRAWN BSS DESIGNED BSS CHECKED GCA PROJ. MGR. CHS SCALE HORIZONTAL: AS NOTED VERTICAL: N/A M&C FILE NUMBER D4.X DRAWING NUMBER D4.3 STATUS: FINAL DRAWINGS REVISION FOR REVIEW PURPOSES ONLY 1