Loading...
HomeMy WebLinkAboutNCG050450_NOI Inpsection Report_20240405 t;s Y ROY COOPER fix' , a Governor �� i lr � ELIZABETH S.BISER , , R 4�� Secretary h,v ` WILLIAM E.TOBY VINSON,JR. NORTH CAROLINA EInterim Director rwlnrn mentaiQuality April 5, 2024 Southern Pipe Inc. Attn: Bryan Mitchell,Owner 135 Random Drive New London, North Carolina 28127 Subject: Compliance Evaluation Inspection NPDES Stouuwater General Permit NCG050000 Certificate of Coverage NCG050450 Southern Pipe Inc. ; Stanly County Dear Mr. Mitchell: On April 4, 2024, a site inspection was conducted for 135 Random Dr, Stanly County,North Carolina. A copy of the Compliance Inspection Report is enclosed for your review. Mr. Bryan Patterson, the facility's Environmental Manager, and Mr. Chris Wall, were present during the inspection and their time and assistance is greatly appreciated. The site visit and file review revealed that the subject facility is covered by NPDES Stormwater General Permit NCG050450. Permit coverage authorizes the discharge of stormwater from the facility to receiving waters designated as Town Creek, class C waters in the Yadkin Pee Dee River Basin. As a result of the inspection, the facility was found to be compliant with the conditions of the NCG050450 permit. Please refer to the enclosed Compliance Inspection Report for additional comments and observations made during the inspection. Feel free to contact kathryn.peterson@deq.nc.gov or(704)235-2201 with any questions or concerns. Sincerely, DocuSigned by: kaceitt kad lit ACFA867EC14A463... l. for Jerry W. Eplin,PE Regional Engineer Land Quality Section Enclosure: Compliance Inspection Report c: Bryan Patterson, Environmental Manager Southern Pipe Inc., 135 Random Dr,New London, North Carolina 28127 DEMLR NPDES Stormwater Permit Laserfiche File ANorth Carolina Department of Environmental Quality I Division of Energy,Mineral,and Land Resources f Mooresville Regional Office 1610 East Center Avenue,Suite 301 I Mooresville,North Carolina 28115 dit 704-235-2100 Compliance Inspection Report Permit:NCG050450 Effective: 06/01/23 Expiration: 05/31/28 Owner: Southern Pipe Inc SOC: Effective: Expiration: Facility: Southern Pipe Inc County: Stanly 135 Random Dr Region: Mooresville New London NC 28127 Contact Person:Sonya Cato Title: Phone:919-980-1512 Directions to Facility: From 52S,turn right onto Random Dr. cross railroad track and immediately turn left. located behind fiber composites. System Classifications: SWNC, Primary ORC: Certification: Phone: Secondary ORC(s): On-Site Representative(s): Related Permits: Inspection Date: 04/03/2024 Entry Time 09:30AM Exit Time: 10:30AM Primary Inspector:Kathryn S Peterson Phone: 704-663-1699 Secondary Inspector(s): Stephanie Landers Reason for Inspection: Other Inspection Type: Compliance Evaluation Permit Inspection Type: Apparel/Printing/Paper/Leather/Rubber Stormwater Discharge COC Facility Status: Compliant ® Not Compliant Question Areas: Storm Water (See attachment summary) Page 1 of 4 Permit: NCG050450 Owner-Facility:Southern Pipe Inc Inspection Date: 04/03/2024 Inspection Type:Compliance Evaluation Reason for Visit: Other Inspection Summary: A compliance inspecton was completed for Southern Pipe Inc on April 3, 2024 at 9:30 AM. Kathryn Peterson and Stephanie Landers completed a full compliance inspection in addition to responding to the facility's representative outfall request. Brian Patterson and Chris Waller were present during the inspection. The facility requests that outfall 001 may be represented by outfall 002. The site is marked in compliance. However, there were a few documentation issues within the SWPPP. Employee training has not be documented since 3/24/2022, an illicit discharge evaluation has not been documented since 9/20/2022,the list of signifanct spills over the past three years is missing 2023 and the beginning of 2024,and the SWPPP itself has not been updated since 9/20/2022. All of these items should be documented/updated/evaluated annually. It is recommened that the ROS request be granted after documentation of the above is received, in addition to the sample results from Q1 of 2024 for the facility's analytical monitoring requirement. Please send the required documentation to kathryn.peterson@deq.nc.gov.After these are received, the ROS request may be processed. Page 2 of 4 Permit: NCG050450 Owner-Facility:Southern Pipe Inc Inspection Date: 04/03/2024 Inspection Type:Compliance Evaluation Reason for Visit: Other Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? 0 ❑ ❑ #Does the Plan include a General Location (USGS)map? ❑ 0 0 #Does the Plan include a"Narrative Description of Practices"? ❑ ❑ 0 #Does the Plan include a detailed site map including outfall locations and drainage areas? 0 0 0 #Does the Plan include a list of significant spills occurring during the past 3 years? ❑ ❑ ❑ #Has the facility evaluated feasible alternatives to current practices? El 0 ❑ #Does the facility provide all necessary secondary containment? ❑ 0 0 #Does the Plan include a BMP summary? 0 0 0 #Does the Plan include a Spill Prevention and Response Plan (SPRP)? ❑ 0 ❑ #Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? 0 0 0 #Does the facility provide and document Employee Training? ❑ ❑ ❑ #Does the Plan include a list of Responsible Party(s)? ❑ ❑ ❑ #Is the Plan reviewed and updated annually? 0 0 El #Does the Plan include a Stormwater Facility Inspection Program? ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ❑ 0 0 Comment: The SWPPP has not be updated since 09/20/2022, employee training has not been documented since 3/24/2022, and the list of significant spills only includes 2019-2022. The SWPPP and employee training needs to be reviewed/completed annually. The significant spill list should include all spills from the past three years; if no spills have occured, document this accordingly. Mr. Brian Patterson will send updated SWPPP documentation, updated employee training records and an updated spill list to kathryn.peterson(a,deq.nc.gov as soon as possible. Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring? ❑ El ❑ Comment: Qualitative monitoring was done for the first half of 2023, but not for the second half of 2023. Ensure to perform qualitative monitoring consistent with permit requirements. Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ❑ El ❑ #Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? El ❑ ❑ Comment: The facility's permit under NCGO5 was recently renewed and now has analytical monitoring requirements. Samples were taken last month for the Q1 sampling requirement, but the facility is still waiting on the results. Results should be sent to kathryn.petersonna,deq.nc.gov once recieved by the faciltV. Permit and Outfalls Yes No NA NE #Is a copy of the Permit and the Certificate of Coverage available at the site? ❑ El ❑ #Were all outfalls observed during the inspection? ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ❑ Page 3 of 4 Permit: NCG050450 Owner-Facility:Southern Pipe Inc Inspection Date: 04/03/2024 Inspection Type:Compliance Evaluation Reason for Visit: Other #Has the facility evaluated all illicit(non stormwater)discharges? ❑ ❑ ❑ Comment: The last illicit discharge evaluation recorded is from 9/20/2022.The permit requries this to be completed once a year. Ensure that the facility completes this evaluation and keeps a record of the monitoring. Facility requested ROS, and it is recommened to grant the request. • Page 4 of 4