Loading...
HomeMy WebLinkAboutWQ0020819_Compliance Inspection Report_20240402 April 2, 2024 Zhiyuan Che 65 Cortland Irvine, CA 92620 Sent Via Email Subject: Compliance Evaluation Inspection Single Family Wastewater Treatment System Permit WQ0020819 Facility: 65 Royal Sunset Drive Chatham County Dear Mr. Che: On March 11, 2024, Michael Hall from the Division of Water Resources, Raleigh Regional Office visited your single- family residence (SFR) wastewater treatment system to evaluate compliance with the subject non-discharge permit referenced above (The Permit). The assistance provided by Jeff Cranmer of Aqwa during the inspection was greatly appreciated. The Permit was issued February 17, 2017 and expired on January 31, 2022. An application to renew the Permit was provided to Angel Leung prior to the inspection with instructions to complete and submit the application. At the time this letter was written, the permit was still expired. If you or Ms. Leung have not submitted the application for permit renewal, please do so as soon as possible. The permit indicates the treatment system consists of a 1,500 gallon baffled septic tank with an effluent filter; a dual recirculating tank and recirculation pump; a 20 gallon per minute (GPM) dosing pump; a control panel; audio and visual high-water alarms; a rain sensor; an ultraviolet (UV) disinfection unit with a stabilization capacity of 10 GPM; a 0.3 acre drip irrigation area with approximately 4,506 linear feet (LF) of drip line containing 2,253 emitters; and all associated piping, valves, controls, and appurtenances. The permit authorizes the operation up to 600 gallons per day (GPD). The authorized irrigation is in accordance with the effluent limits and monitoring requirements established within the Non-Discharge Permit. The items below show what conditions were noted at your facility: Septic Tank You are required to inspect the septic tank at least yearly to determine if solids must be removed or if other maintenance is necessary. Septic tanks should be pumped out every five years or when the solids level is found to be more than 1/3 of the liquid depth in the septic tank compartment, whichever is greater. A pumping company can check the status periodically and evaluate when pumping is required. DocuSign Envelope ID: 9AC82AC5-31DE-4C0E-86E9-763347161EB6 Zhiyuan Che WQ0020819 April 2, 2024 Page 2 of 3 The permittee has an operation and maintenance contract with Aqwa, who had a technician present at the time of the inspection. The level in the septic tank is monitored by Aqwa, who will notify you when the tank requires pumping. The septic filter is cleaned every 6 months by Aqwa, and was last cleaned September 11, 2023. Treatment System Operation and Maintenance As detailed in the permit, the wastewater treatment system shall be effectively maintained and operated at all times so there is no discharge to surface waters, nor any contravention of groundwater or surface water standards. The permittee has an operation and maintenance contract with Aqwa, who had a technician present at the time of the inspection. At the time of this inspection the treatment system appeared to be effectively maintained and operated. Disinfection Your system uses an ultra-violet (UV) light system for disinfection of the discharged wastewater. A UV disinfection system provides effective disinfection and prevents/limits harmful bacteria from discharging to the environment. Unless the UV disinfection unit is monitored by telemetry, the unit shall be checked weekly. The lamp(s) and quartz sleeve(s) shall be cleaned or replaced as needed to ensure proper disinfection of the discharged wastewater. Aqwa monitors the operation of the UV system through telemetry, and demonstrated during the inspection that the system was operating as required. Drip Field Operation and Maintenance The system shall be inspected monthly to make certain of the proper operation of the drip lines, that the system is free of leaks, that the vegetative growth allows a proper drip pattern, that the soil is assimilating the disposed treated wastewater with no surface runoff, and that no objectionable odors are being generated. Any visible signs of a malfunctioning system shall be documented, and steps taken to correct the problem. A perimeter fence consisting of a minimum of 2-strand wire will be in place surrounding the entire drip field. This fence will be inspected and repaired by the permittee, as necessary. On the day of the inspection, two small leaks were identified in Zone 3. These were immediately repaired by Aqwa, following which the system appeared to be operating without leaks. The drip field appeared to be assimilating the waste and no ponding and/or runoff was observed. No fence was observed surrounding the drip field. Also, a number of downed trees and piles of cut brush were observed on the drip field. The trees and brush should be removed from the field to prevent damage to the drip lines, and to facilitate inspection of the system. Record-Keeping and Payments You are required to maintain all maintenance records onsite for a minimum of three years and available for inspection. The permit requires the permittee to “pay the annual administering and compliance monitoring fee within thirty days after being billed by the Division.” Required records were provided, as required by the permittee or by their contractor Aqwa. Division records indicate the required annual fee ($60 per year) for the period ending April 30, 2024 and due May 5, 2023 has been paid. There are no overdue fees for the subject Non-Discharge permit. DocuSign Envelope ID: 9AC82AC5-31DE-4C0E-86E9-763347161EB6 Zhiyuan Che WQ0020819 April 2, 2024 Page 3 of 3 Compliance Issues The following issues are not compliant with the permit: 1. Permit Condition I.1 states “No later than six months prior to the expiration of this permit, the Permittee shall request renewal of the permit on official Division forms.” At the time of the inspection, the permit was expired. An application to renew the permit was provided to Ms. Leung on February 27, 2024. You will need to submit the application for a renewal as soon as possible. Currently you are discharging without a permit, which can result in fines of up to $ 10,000 per day until the permit is reissued. 2. Permit Condition III.8 states “Public access to the irrigation sites and wastewater treatment facilities shall be prohibited. Fencing shall be provided to prevent access to the irrigation site (minimum 2-strand wire) and treatment units shall be secured with locks on all tank accesses and control panels”[15A NCAC 02T .0605(i)] At the time of the inspection, there was no fencing in place surrounding the drip field. As indicated, a minimum of 2-wire fencing is required around the drip field. Within 30 days of receiving this letter, please submit a written response to the Raleigh Regional Office indicating the actions you will, or have taken to address the compliance issues listed above. Please continue to periodically inspect the wastewater treatment system to ensure the treatment components are always maintained and in good operating order. If you have questions or comments about this inspection or the requirements to take corrective action (if applicable), then please contact Michael Hall at 919-791-4237 or at michael.hall@deq.nc.gov Sincerely, Michael Hall, Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ Attachments: Compliance Inspection Report Field Inspection Form Ec: Angel Leung Tammy Riggan, Aqwa Laserfiche DocuSign Envelope ID: 9AC82AC5-31DE-4C0E-86E9-763347161EB6 Compliance Inspection Report Permit:WQ0020819 Effective:02/17/17 Expiration:01/31/22 Owner :Zhiyuan Che SOC: Contact Person: Region: County: Directions to Facility: Chatham Raleigh Zhiyuan Che Effective:Expiration:Facility:65 Royal Sunset Dr. SFR 65 Royal Sunset Dr Durham NC 27713 Title:Phone: I-40, exit 278 NC-55S, 4.4 mi. Rt on O'Kelly Chapel Rd., 2 mi., Rt on Royal Sunset Dr., First house on the left. Secondary ORC(s): Phone:Certification:Primary ORC: System Classifications: On-Site Representative(s): Related Permits: Secondary Inspector(s): Primary Inspector: Inspection Date:Exit Time:Entry Time: Phone: 03/11/2024 09:10AM 10:14AM Michael Hall 919-791-4237 Facility Status: Permit Inspection Type: Reason for Inspection:Inspection Type: Not CompliantCompliant Routine Single-Family Residence Wastewater Irrigation Compliance Evaluation Question Areas: Miscellaneous Questions Permit Status Septic Tank Sand Filter/Treatment Pods Disinfection UV Pump Tank Drip or Irrigation General (See attachment summary) Page 1 of 5 DocuSign Envelope ID: 9AC82AC5-31DE-4C0E-86E9-763347161EB6 4/2/2024 Inspection Date: Permit: Inspection Type : Owner - Facility: Reason for Visit: WQ0020819 03/11/2024 Compliance Evaluation Zhiyuan Che Routine Inspection Summary: On March 11, 2024, Michael Hall from the Division of Water Resources, Raleigh Regional Office visited your single-family residence (SFR) wastewater treatment system to evaluate compliance with the subject non-discharge permit referenced above (The Permit). The assistance provided by Jeff Cranmer of Aqwa during the inspection was greatly appreciated. The Permit was issued February 17, 2017 and expired on January 31, 2022. An application to renew the Permit was provided to Angel Leung prior to the inspection with instructions to complete and submit the application. At the time this letter was written, the permit was still expired. If you or Ms. Leung have not submitted the application for permit renewal, please do so as soon as possible. The permit indicates the treatment system consists of a 1,500 gallon baffled septic tank with an effluent filter; a dual recirculating tank and recirculation pump; a 20 gallon per minute (GPM) dosing pump; a control panel; audio and visual high-water alarms; a rain sensor; an ultraviolet (UV) disinfection unit with a stabilization capacity of 10 GPM; a 0.3 acre drip irrigation area with approximately 4,506 linear feet (LF) of drip line containing 2,253 emitters; and all associated piping, valves, controls, and appurtenances. The permit authorizes the operation up to 600 gallons per day (GPD). The authorized irrigation is in accordance with the effluent limits and monitoring requirements established within the Non-Discharge Permit. The items below show what conditions were noted at your facility: Septic Tank You are required to inspect the septic tank at least yearly to determine if solids must be removed or if other maintenance is necessary. Septic tanks should be pumped out every five years or when the solids level is found to be more than 1/3 of the liquid depth in the septic tank compartment, whichever is greater. A pumping company can check the status periodically and evaluate when pumping is required. The permittee has an operation and maintenance contract with Aqwa, who had a technician present at the time of the inspection. The level in the septic tank is monitored by Aqwa, who will notify you when the tank requires pumping. The septic filter is cleaned every 6 months by Aqwa, and was last cleaned September 11, 2023. Treatment System Operation and Maintenance As detailed in the permit, the wastewater treatment system shall be effectively maintained and operated at all times so there is no discharge to surface waters, nor any contravention of groundwater or surface water standards. The permittee has an operation and maintenance contract with Aqwa, who had a technician present at the time of the inspection. At the time of this inspection the treatment system appeared to be effectively maintained and operated. Disinfection Your system uses an ultra-violet (UV) light system for disinfection of the discharged wastewater. A UV disinfection system provides effective disinfection and prevents/limits harmful bacteria from discharging to the environment. Unless the UV disinfection unit is monitored by telemetry, the unit shall be checked weekly. The lamp(s) and quartz sleeve(s) shall be cleaned or replaced as needed to ensure proper disinfection of the discharged wastewater. Aqwa monitors the operation of the UV system through telemetry, and demonstrated during the inspection that the system was operating as required. Drip Field Operation and Maintenance The system shall be inspected monthly to make certain of the proper operation of the drip lines, that the system is free of leaks, that the vegetative growth allows a proper drip pattern, that the soil is assimilating the disposed treated wastewater with no surface runoff, and that no objectionable odors are being generated. Any visible signs of a malfunctioning system shall be documented, and steps taken to correct the problem. A perimeter fence consisting of a minimum of 2-strand wire will be in place surrounding the entire drip field. This fence will be inspected and repaired by the permittee, as necessary. Page 2 of 5 DocuSign Envelope ID: 9AC82AC5-31DE-4C0E-86E9-763347161EB6 Inspection Date: Permit: Inspection Type : Owner - Facility: Reason for Visit: WQ0020819 03/11/2024 Compliance Evaluation Zhiyuan Che Routine On the day of the inspection, two small leaks were identified in Zone 3. These were immediately repaired by Aqwa, following which the system appeared to be operating without leaks. The drip field appeared to be assimilating the waste and no ponding and/or runoff was observed. No fence was observed surrounding the drip field. Also, a number of downed trees and piles of cut brush were observed on the drip field. The trees and brush should be removed from the field to prevent damage to the drip lines, and to facilitate inspection of the system. Record-Keeping and Payments You are required to maintain all maintenance records onsite for a minimum of three years and available for inspection. The permit requires the permittee to “pay the annual administering and compliance monitoring fee within thirty days after being billed by the Division.” Required records were provided, as required by the permittee or by their contractor Aqwa. Division records indicate the required annual fee ($60 per year) for the period ending April 30, 2024 and due May 5, 2023 has been paid. There are no overdue fees for the subject Non-Discharge permit. Compliance Issues The following issues are not compliant with the permit: 1.Permit Condition I.1 states “No later than six months prior to the expiration of this permit, the Permittee shall request renewal of the permit on official Division forms.” At the time of the inspection, the permit was expired. An application to renew the permit was provided to Ms. Leung on February 27, 2024. You will need to submit the application for a renewal as soon as possible. Currently you are discharging without a permit, which can result in fines of up to $ 10,000 per day until the permit is reissued. 2.Permit Condition III.8 states “Public access to the irrigation sites and wastewater treatment facilities shall be prohibited. Fencing shall be provided to prevent access to the irrigation site (minimum 2-strand wire) and treatment units shall be secured with locks on all tank accesses and control panels”[15A NCAC 02T .0605(i)] At the time of the inspection, there was no fencing in place surrounding the drip field. As indicated, a minimum of 2-wire fencing is required around the drip field. Within 30 days of receiving this letter, please submit a written response to the Raleigh Regional Office indicating the actions you will, or have taken to address the compliance issues listed above. Please continue to periodically inspect the wastewater treatment system to ensure the treatment components are always maintained and in good operating order. If you have questions or comments about this inspection or the requirements to take corrective action (if applicable), then please contact Michael Hall at 919-791-4237 or at michael.hall@deq.nc.gov Page 3 of 5 DocuSign Envelope ID: 9AC82AC5-31DE-4C0E-86E9-763347161EB6 Inspection Date: Permit: Inspection Type : Owner - Facility: Reason for Visit: WQ0020819 03/11/2024 Compliance Evaluation Zhiyuan Che Routine Permit Status Yes No NA NE # Is the current resident in the home the Permittee? # If not, does the resident rent from the Permittee? Change of Ownership form needed? (Mail the form with the inspection letter) # Is there an inspection and maintenance agreement with a contractor? If YES, who is the contractor (include contact info)? Aqwa Aqwa monitors the system and performs O&M on a regular basis.Comment: Septic Tank Yes No NA NE *** The septic tank and filters should be checked annually and pumped/cleaned as needed. *** Is all wastewater from the home connected to the septic tank? # Does the permittee/resident know where the septic tank is located? Has the septic tank been pumped in the last 5 years? If YES, describe if known and proof (include date pumped): # Does the septic tank have an EFFLUENT FILTER or SANITARY T? If FILTER, when was the filter cleaned and by who?Aqwa 09/11/2023 Aqwa notifies the permittee when the tank needs to be pumpedComment: Sand Filter/Treatment Pods Yes No NA NE *** Accessible sand filter surfaces shall be raked/leveled every 6 months and vegetative growth shall be removed manually. *** # Is system something other than a sand filter? # If YES, what kind? (examples - Peat, Textile or brand name - Advantex, etc.)Two Advantex AX-20 pods # Does the permittee know where the sandfilter is located? Does the sandfilter require maintenance? If maintenace is required, explain: Permit description of the system does not include the Advantex Pods.Comment: Disinfection UV Yes No NA NE *** UV unit shall be checked weekly. Lamps/sleeves should be cleaned/replaced as needed to ensure proper disinfection. *** Is UV working? Has the UV Unit been serviced and bulbs cleaned? # Who completes the weekly check for the UV? ( Non-Discharge)Aqwa Comment: Pump Tank Yes No NA NE *** All pump and alarm sytems shall be inspected monthly. (Non-Discharge) *** Page 4 of 5 DocuSign Envelope ID: 9AC82AC5-31DE-4C0E-86E9-763347161EB6 Inspection Date: Permit: Inspection Type : Owner - Facility: Reason for Visit: WQ0020819 03/11/2024 Compliance Evaluation Zhiyuan Che Routine Is the pump working? Is the audible and visual high water alarm operational? # Does the permittee know how to check the pump & high water alarm? # Last functional test: Comment: Drip or Irrigation Yes No NA NE *** Irrigation sysetm shall be inspected monthly to ensure system is free of leaks and equipment is operating as designed. *** # Type of system (DRIP or IRRIGATION):Drip # If IRRIGATION, number of sprinkler heads: Are buffers and setbacks adequate? Is the site free of ponding and runoff? Does the application equipment appear to be working properly? Is there a minimum two wire fence surrounding the entire irrigation area? No fence around drip field.Comment: General Yes No NA NE # Are the treatment units locked and/or secured? # Has resident had any sewage problems? If YES, explain: Does the system match the permit description? If NO, explain: Permit description does not include the two Advantex Pods. Is the system compliant? Is the system failing? (If yes, take pictures if possible) If system is failing, describe any exposures to people/animals or environmental risks. System does not have a fence around the drip field.Comment: Page 5 of 5 DocuSign Envelope ID: 9AC82AC5-31DE-4C0E-86E9-763347161EB6 DocuSign Envelope ID: 9AC82AC5-31DE-4C0E-86E9-763347161EB6 DocuSign Envelope ID: 9AC82AC5-31DE-4C0E-86E9-763347161EB6