HomeMy WebLinkAboutNCG550250_CEI_Letter_20240320ROY COOPER
Governor
ELIZABETH S. BISER
Secretary
RICHARD E. ROGERS, JR.
Director
Irvin J. Myers, Homeowner
372 Spillman Road
Mocksville, NC 27028
NORTH CAROLINA
Environmental Quality
March 21, 2024
SUBJECT: Compliance Evaluation Inspection
Single Family Residence Wastewater Treatment System for 372 Spillman Road,
Mocksville, NC 27028
NPDES General Permit #: NCG550000, Certificate of Coverage #: NCG550250
Davie County
Dear Mr. Myers:
On March 7th, 2024, Ron Boone, of the Winston-Salem Regional Office of the NC Division of Water
Resources, conducted a compliance evaluation inspection of your single-family wastewater treatment
system. Thank you for your assistance during the inspection. The inspection findings are summarized
on the attached Water Compliance Inspection Report.
If you have any questions or concerns regarding the inspection or this report, please contact Mr. Boone
by phone at 336.776.9690 or by email at ron.boone@deq.nc.gov.
Sincerely,
DocuSiTgned by:
-41
5119
B 9E22 C94E
Lon . nI er, egional Supervisor
Water Quality Regional Operations Section
Winston-Salem Regional Office
Division of Water Resources, NCDEQ
Attachments:
1. Water Compliance Inspection Report
2. NCG550000 General NPDES Wastewater Permit
3. List of Certified Laboratories
4. Chlorine Information
DffNorth Carolina Department of Environmental Quality I Division of Water Resources
oan caaouNn
Winston-Salem Regional Office 1 450 W. Hanes Mill Rd, Suite 300 I Winston-Salem, North Carolina 27105
M336.776.9800
oep.m.m or em�nmen� Qualm
United States Environmental Protection Agency
Form Approved.
EPA Washington, D.C. 20460
OMB No. 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN 2 u 3 I NCG550250 111 121 24/03/07 I17 18 I C I 19 I s I 20L]
21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6
Inspection
Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved -------------------
67
I 72 I ni I 73 � I 74 79 I I I I I I I80
70 I I 71 I LL -1 I I
LJ
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES Dermit Number)
12:OOPM 24/03/07
20/12/04
372 Spillman Road
372 Spillman Rd
Exit Time/Date
Permit Expiration Date
Mocksville NC 27028
01:OOPM 24/03/07
25/10/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Irvin J Myers,372 Spillman Rd Mocksville NC 27028//336-998-6268/
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Ron Boone cuSigned by: DWR/WSRO WQ/336-776-9690/
Do
osier& Boo., 3/19/2024
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
DocuSigned by: 3/21/2024
- -T. 5,,d r
FL
EPA Form18bU-'fl4ev 9-94) Previous editions are obsolete.
Page#
NPDES yr/mo/day Inspection Type
NCG550250 I11 12I 24/03/07 117 18 i c i
(Cont.)
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
On March 7th, 2024, Ron Boone, of the Winston-Salem Regional Office of the NC Division of Water
Resources, conducted a compliance evaluation inspection of your single family wastewater treatment
system. Thank you for assisting Mr. Boone in completing the inspection. The inspection results are
summarized below:
You were not available to be present during the inspection but you informed Mr. Boone by phone
prior to the inspection that the septic tank is pumped as needed. Mr. Boone reminded you it should
be pumped no less frequently than every five years according to the permit. Pumping records were
not readily available during the inspection. The permit also requires that you keep records of when
you have the tank pumped.
No chlorine was available for evaluation during the inspection. The chlorinator was accessible but
there appeared there was no chlorine in it at the time. You should keep each chlorinator tube stocked
with two to three tablets at all times. Also, be sure you are using the correct type of chlorine. You
must use chlorine tablets suitable for use in disinfection of wastewater. Their main ingredient must be
60 to 70 percent of calcium hypochlorite and they are about 2-5/8" in diameter and 1" thick. We have
attached information to assist you in finding the proper type of chlorine.
Mr. Boone was not able to locate the discharge pipe during his inspection but you indicated over the
phone that you know where it is. Samples of the effluent have not been collected and analyzed as
required by the permit. You also informed Mr. Boone that you have never seen it discharge.
For your information, pursuant to Part I.C.(1.) of the general permit (Page 3), you are required to
have the effluent tested annually for the constituents listed in Part I.C.(1.) by a NC state certified
laboratory. We have also included a list of NC certified laboratories along with this inspection report. If
you can't collect a sample because you cannot catch it discharging, then no analyes are required.
You are technically non -compliant with the permit. If you have any questions or concerns about
compliance, the inspection, or this report, please contact Mr. Boone by phone at 336-776-9690, or by
email at ron.boone@deq.nc.gov.
Page#
Permit: NCG550250
Inspection Date: 03/07/2024
Owner -Facility: 372 Spillman Road
Inspection Type: Compliance Evaluation
Permit
(If the present permit expires in 6 months or less). Has the permittee submitted a new
application?
Is the facility as described in the permit?
# Are there any special conditions for the permit?
Is access to the plant site restricted to the general public?
Is the inspector granted access to all areas for inspection?
Comment: Please refer to the inspection summary section of this report.
Yes No NA NE
❑ ❑ ■ ❑
■ ❑ ❑ ❑
❑ ❑ ❑
❑ ❑ ❑
■ ❑ ❑ ❑
Page# 3