Loading...
HomeMy WebLinkAboutNCG550235_CEI_Letter_20240320ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director Nathan Ray Thomas, Homeowner 4560 Merriweather Court Winston-Salem, NC 27 NORTH CAROLINA Environmental Quality March 21, 2024 SUBJECT: Compliance Evaluation Inspection Single Family Residence Wastewater Treatment System for 372 Spillman Road, Mocksville, NC 27107 NPDES General Permit #: NCG550000, Certificate of Coverage #: NCG550235 Davie County Dear Mr. Thomas: On March 7th, 2024, Ron Boone, of the Winston-Salem Regional Office of the NC Division of Water Resources, conducted a compliance evaluation inspection of your single-family wastewater treatment system. Thank you for your assistance during the inspection. The inspection findings are summarized on the attached Water Compliance Inspection Report. If you have any questions or concerns regarding the inspection or this report, please contact Mr. Boone by phone at 336.776.9690 or by email at ron.boone@deq.nc.gov. Sincerely, DocuSigned bbyyy- -41 ig 45B 9E22 C94E Lon nI er, egional Supervisor Water Quality Regional Operations Section Winston-Salem Regional Office Division of Water Resources, NCDEQ Attachments: 1. Water Compliance Inspection Report 2. NCG550000 General NPDES Wastewater Permit 3. List of Certified Laboratories 4. Chlorine Information DffNorth Carolina Department of Environmental Quality I Division of Water Resources oan caaouNn Winston-Salem Regional Office 1 450 W. Hanes Mill Rd, Suite 300 I Winston-Salem, North Carolina 27105 M336.776.9800 oep.m.m or em�nmen� Qualm United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 2 u 3 I NCG550235 111 121 24/03/07 I17 18 I C I 19 I s I 20L] 21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 I 72 I ni I 73 � I 74 79 I I I I I I I80 70 I I 71 I LL -1 I I LJ Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES Dermit Number) 03:OOPM 24/03/07 19/06/25 4560 Merriweather Court 4560 Merriweather Ct Exit Time/Date Permit Expiration Date Winston Salem NC 27107 04:OOPM 24/03/07 20/10/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Nathan Ray Thomas,4560 Merriweather Ct Winston Salem NC 27107//336-784-1633/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Ron Boone Docusigned by: DWR/WSRO WQ/336-776-9690/ osiaecl 3/19/2024 B20FSDD5F2A3460... Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date DocuSigned by: 3/21/2024 145B49E225C94EA... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type NCG550235 I11 12I 24/03/07 117 18 i c i (Cont.) Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On March 7th, 2024, Ron Boone, of the Winston-Salem Regional Office of the NC Division of Water Resources, conducted a compliance evaluation inspection of your single family wastewater treatment system. Thank you for assisting Mr. Boone in completing the inspection. The inspection results are summarized below: The outfall was inspected and Mr. Boone noted no concerns. It was discharging at the time of the inspection and the water looked clean and clear with no solids or odor. The effluent hasn't been tested as required by the permit. We have included an attachment to this report that lists NC certified laboratories where you can have the water tested. During the inspection you informed Mr. Boone that that the septic tank is pumped as needed. Mr. Boone reminded you it should be pumped no less frequently than every five years according to the permit. Pumping records were not readily available during the inspection. The permit also requires that you keep records of when you have the tank pumped. You showed Mr. Boone the chlorine tablets you use. They are the correct type, i.e. for wastewater disinfection and between 60 and 70 percent of calcium hypochlorite, but you had some 3" and 1" tablets, which is also acceptable. You should keep each chlorinator tube stocked with the equivalent of two to three 3" tablets at all times. We have attached information to assist you in finding the proper type of chlorine. You are technically non -compliant with the permit due to not having it tested annually. If you have any questions or concerns about compliance, the inspection, or this report, please contact Mr. Boone by phone at 336-776-9690, or by email at ron.boone@deq.nc.gov. Page# Permit: NCG550235 Inspection Date: 03/07/2024 Owner -Facility: 4560 Merriweather Court Inspection Type: Compliance Evaluation Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Please refer to the inspection summary section of this report. Yes No NA NE ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ Page# 3