On November 1, 2007, the Division of Water Quality (DWQ) received your application dated October 22,
2007, to fill or otherwise impact 30 linear feet of perennial stream to construct the proposed single and
multi-family residential development. The DWQ has determined that your application was incomplete
and/or provided inaccurate information as discussed below. The DWQ will require additional
information in order to process your application to impact protected wetlands and/or streams on the
subject property. Therefore, unless we receive five copies of the additional information requested below,
we will have to move toward denial of your application as required by 15A NCAC 2H .0506 and will
place this project on hold as incomplete until we receive this additional information. Please provide the
following information so that we may continue to review your project.
Additional Information Requested:
1. Please re-submit your site plans on full plan sheets at a scale of no smaller than 1 "=50' with
topographic contours.
2. Please provide the location of any proposed stormwater management practices as required by
GC3631.
3. Please provide plans and profiles for all the stormwater management devices as required by
GC3631.
4. Please indicate all stormwater inlets and outfalls on the site plan.
5. Please provide an inventory of proposed project imperviousness area based on the estimated
built-out conditions. Please include all proposed building footprints, roads, driveways, sidewalks,
gravel-surfaced areas, amenity areas, etc.
401 OversighUExpress Review Permitting Unit
1650 Mail Service Center, Raleigh, North Carolina 27699-1650
2321 Crabtree Boulevard, Suite 250, Raleigh, North Carolina 27604
Phone: 919-733-1786 /FAX 919-733-6893 /Internet: http://h2o.enr.state.nc.us/ncwetlands
NonehCarolina
~atura!!y
An Equal Opportunity/Affirmative Action Employer - 50% Recycled/10% Post Consumer Paper
Thomson-Worley, Inc.
Page 2 of 2
November 19, 2007
6. Please indicate proposed lot layout as overlays on the site plan.
7. Please locate any planned sewer lines on the site plan.
8. Please indicate all stream impacts including all fill slopes, dissipaters, and bank stabilization on
the site plan.
9. Please indicate all wetland impacts including fill slopes on the site plan.
10. Please locate all isolated or non-isolated wetlands, streams, and other waters of the State as
overlays on the site plan.
11. Please provide a qualitative indirect and cumulative impact analysis for the project. Please see
DWQ's policy for guidance on our website at:
http://h2o. enr.state.nc.us/ncwetlands/documents/InterimInternalPolicyCumulativeImpact. doc
Please submit this information within 30 calendar days of the date of this letter. If we do not receive this
requested information within 30 calendar days of the date of this letter, your project will be withdrawn
and you will need to reapply with a new application and a new fee.
This letter only addresses the application review and does not authorize any impacts to wetlands, waters
or protected buffers. Please be aware that any impacts requested within your application are not
authorized (at this time) by the DWQ. Please call Ms. Cyndi Karoly or Mr. Ian McMillan at 919-733-
1786 if you have any questions regarding or would like to set up a meeting to discuss his matter.
Sincerely, / ~/
/(,/ "401 Oversight/Express Review Permitting Unit
CBKlijm
cc: Kevin Barnett, DWQ Asheville Regional Office
USACE Asheville Regulatory Field Office
File Copy
Central Files
Filename: 071862GrandVistaSDWaterLineExt(Buncombe)On_Hold