Loading...
HomeMy WebLinkAboutSW3231104_Supplement-EZ Form_20240318 SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Holy Spirit Catholic Church 2 Project Area(a) Tm _ 7.76 3 Coastal Wetland Area(ac) 0 4 Surface Water Area(ac) _ 0 _ 5 Is this_project High or Low Density? High �6 Does this project use an off-site SCM? No COMPLIANCE WITH 021-1.1003 4} 7 Width of vegetated setbacks provided(feet) 30 8 Will the vegetated setback remain vegetated? Yes 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-c9? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration stem____ 12 Bioretention Cell 13 Wet Pond 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 1 17 Rainwater Harvesting(RWH) 18 Green Roof 19 Level Spreader-Filter Strip(LS-FS1_______~~ 20 Disconnected Impervious Surface(DIS) 21 Treatment Swale 22 Dry Pond 23 StormFilter 24 Silva Cell 25 Baytlter 26 Filterra FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: David Lutz,PE I Partner 28 Organization: _ CES Group Engineers,LLP 29 Street address: 3525 Whitehall Park Dr.,Suite 150 30 City State,Zip: Charlotte,NC 28273 31 Phone numbers:_ 704-489-1500 32 Email: dlutz@ces-group.net Certification Statement: <J I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans,specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer Signature of Designer Sea! Date DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so, number of drainage areas/SCMs 1 3 Does this project have low density areas? No 4 If so, number of low density drainage areas 0 Is all/part of this project subject to previous rule 5 versions? Yes FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 4 T pe of SCM N/A Sand Filter 5 Total BUA from project (sq ft) 6 1995 rules 0 SL 2006-246 33884 sf 2008 rules IIIIIIIIIIIIIMIIII 0 MI 2017 rules 111111111111111111/ 0 INew BUA on subdivided lots (subject to permitting) (sq ft) N/A 1995 rules SL 2006-246 2008 rules MI 2017 rules New BUA not on subdivided lots (subject to illrl 8 permitting) (sf) 1995 rules SL 2006-246 III 2008 rules 2017 rules 42782 sf 9 Offsite - total area (sq ft) aNIIIIIIIIIIIIIIIIIIIMIIIIIIIIII.am 1995 rules SL 2006-246 _ 2008 rules 2017 rules 10 Offsite BUA (sq ft) 111111111111 1995 rules SL 2006-246 2008 rules I2017 rules Design storm (inches) 1 in 1995 rules SL 2006-246 I2008 rules 2017 rules Breakdown of new BUA: - Parkin• s• ft 36659 sf - Sidewalk s• ft 3439 sf - Roof(sq ft) _ - Roadway(sqn - Future (sq ft) - Other, please specify in the comment box below (sq ft) New infiltrating permeable pavement on subdivided 13 lots (sq ft) New infiltrating permeable pavement not on 14 subdivided lots tsq ft) Existing BUA that will remain (not subject to 15 permitting) (sq ft) - 18466 sf 16 Existing BUA that is already permitted (sq ft) 17 Existing BUA that will be removed (sq ft) 15418 sf 18 Percent BUA 56% 19 Design volume of SCM (cu ft) 20 Calculation method for design volume ADDITIONAL INFORMATION Please use this space to provide any additional 21 information about the drainage area(s): SAND FILTER 1 Drainage area number 1 2 Minimum re uired treatment volume cu ft 4848 sf GENERAL MDC FROM 02H .1050 3 Is the SCM sized to treat the SW from all surfaces at build-out? Yes 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM (H:V)? 3:1 6 Does the SCM have retaining walls, gabion walls or other engineered No side slopes? 7 Are the inlets, outlets, and receiving stream protected from erosion Yes (10-year storm)? 8 Is there an overflow or bypass for inflow volume in excess of the Yes design volume? 9 What is the method for dewatering the SCM for maintenance? Pump (preferred) 10 If applicable, will the SCM be cleaned out after construction? Yes 11 Does the maintenance access comply with General MDC (8)? Yes 12 Does the drainage easement comply with General MDC (9)? Yes 13 If the SCM is on a single family lot, does (will?)the plat comply with No General MDC (10)? 14 Is there an O&M Agreement that complies with General MDC (11)? Yes 15 Is there an O&M Plan that complies with General MDC (12)? Yes 16 Does the SCM follow the device specific MDC? Yes 17 Was the SCM designed by an NC licensed professional? Yes SAND FILTER MDC FROM 02H .1056 18 SHWT elevation (fmsl) 790 19 Type of sand filter(open or closed) Open 20 If closed, will the filter will be pre-cast or pour-in-place? 21 If closed, top of grate elevation (fmsl) 22 Is this sand filter designed to attenuate peak flows? No Sediment Chamber 23 Volume that can be retained in the sediment chamber (cubic feet) 2706 cf 24 Will there be a permanent pool in the sediment chamber? No 25 Bottom of the sediment chamber(fmsl) 798.00 26 Area of the sediment chamber(square feet) 2772 sf 27 Physical depth of the sediment chamber (inches) 19 in 28 Ponding depth in the sediment chamber, above any permanent pool 19 in (inches) 29 Elevation of top of weir between chambers (fmsl) 799.6 Sand Chamber 30 Volume that can be retained in the sand chamber (cubic feet) 5406 cf 31 Bottom of the sand chamber (fmsl) 795.50 32 Area of the sand chamber (square feet) _ 2745 sf 33 Physical depth of the sand chamber (inches) 49 in 34 Ponding depth in the sand chamber, above the sand surface 19 in (inches) 35 Elevation of the bypass device (fmsl) 799.6 36 Type of bypass device level spreader 37 Mechanism for distributing flow over the sand surface weir clean washed astm 38 Sand specification for sand chamber iand..EiLter 1 c33 1:49 PM 3/15/2024 SAND FILTER 39 Depth above underdrain pipe (inches) 18 in Will the media be maintained to drain at least two inches per hour at 40 the sand surface? Yes 41 Is at least one clean-out pipe provided at the low point of each Yes underdrain line? 42 Will clean-out i es be ca ed? Yes ADDITIONAL INFORMATION 43 Please use this space to provide any additional information about the sand filter(s): ANZISHINOIMIEMON Sand Filter 2 1:49 PM 3/15/2024