HomeMy WebLinkAbout310557_Irrigation Design Update_20240314Sheetl IRRIGATION SYSTEM DESIGN PARAMETERS Landowner/Operator Name: Chadwick D. Phillips, CDP Farm-AWS310557 County: Duplin Address: 140 S Country Club Drive Pivot Add't. w/Digester Kenansville, NC 28349 Farm Address Date: 9/19/2023 Telephone: 910-271-1779 2222 Bowdens Road 3/14/2024 Faison, NC 28341 Table 1 - Field Specifications Approximate Maximum Maximum Maximum Application Useable Size Application per Irrigation Field of Field Rate Cycle Number (acres) Soil Tvne Slooe % Croo(s) (In/hr) (inches) Comments T1425 35.2 Goldsboro 0-2 Row Crops 0.5 1 Pivot 1 (Replaces pulls 6-9,12-19) T1418 12.67 Goldsboro 0-2 Row Crops 0.5 1 Pulls 1-3 T1418 3.5 Rains 0-2 Row Crops 0.5 1 Pull 4 51.37 Note: Pull 5 removed due to digester location. Sheet2 TABLE 2 - Travelling Irrigation Gun Settings Make, Model and Type of Equipment: Center Pivot; Existing Pulls Field No. Travel Application TRAVEL LANE Wetted Nozzle Operating Operating and Speed Rate Effective Effective Diameter Diameter Pressure Pressure Arc Hydrant No. (ft/min) (in/hr.) Width(ft.) Length(ft) (feet) (Inches) at Gun(psi) at reel(psi) Pattern Comments - Acres r)er pull Pivot 1 Icenter Pivot acreage computer calculated; machine length-784' with end gun radius-100' 35.20 Existing Pulls from Original Design 1 2.62 0.33 194 1026 260 0.86 60 77 270 4.57 2 2.62 0.33 180 986 260 0.86 60 77 270 4.07 3 2.62 0.33 194 906 260 0.86 60 77 270 4.03 4 2.62 0.33 194 786 260 0.86 60 77 270 3.50 TOTAL 51.37 Sheet3 TABLE 3 - Solid Set Irrigation Gun Settings Make, Model and Type of Equipment N/A Operating Parameters Field No Wetted Hydrant Spacing(ft) Application Nozzle Operating Operating and Number of Diameter Along Between Rate Diameter Pressure Time Line No. Hydrants (feet) Pipelines Pipelines in/hr (inches) at Gun(psi) at Hydrant(hr.) Comments -Acres per zone 0 TOTAL 0.00 Sheet4 TABLE 4 - Irrigation System Specifications Pivot 1 Traveling Solid Set Pivot/Linear Pivot/Linear Pivot/Linear Irrigation Gun Irrigation Irrigation Irrigation Irrigation Flow Rate of Sprinkler pm 110 0 0 0 0 Operating Pressure at Pump (psi) #DIV/01 #DIV/O! #DIV/O! #DIV/O! #DIV/O! Design Precipitation Rate (in/hr) 0.25 0.00 See Chart See Chart See Chart Hose/Machine Length feet XXXX)v xx 784.0 0.0 0.0 Type of Speed Compensation Mechanical xxxxx OCX XXXXXXXX xxxxx xx XXxOOOCX Pump Type (PTO, Engine, Electric) Engine Engine Engine Engine Engine Pump Power Requirement (hp) #DIV/O! #DIV/O! #DIV/O! #DIV/O! #DIV/O! TABLE 5 - Thrust Block Specifications 6" 4" 2" THRUST BLOCK THRUST BLOCK THRUST BLOCK LOCATION AREA sq. ft.) AREA (sq. ft.) AREA sq. ft. 90 degree bend 8.8 4.3 1.1 Dead End 6.2 3.0 0.8 Tee 4.4 2.1 0.5 Gate Valve 6.2 3.0 0.8 45 degree bend 4.7 2.3 0.6 Page 1 Sheet5 IRRIGATION SYSTEM DESIGNER Name: Micah Kevin Weston, CID Company: Murphy -Brown, LLC dba Smithfield Hog Production Address: 2822 Hwy 24 West, P.O. Box 856 Warsaw, NC 28398 Phone: (910)293-3434 Required Documentation The following details of design and materials must accompany all irrigation designs: 1. A scale drawing of the proposed irrigation system which includes hydrant locations, pipelines, thrust block locations and buffer areas where applicable. 2. Assumptions and computations for determining total dynamic head and horsepower requirements. 3. Computations used to determine all mainline and lateral pipe sizes. 4. Sources and/or calculations used for determining application rates. 5. Computations used to determine the size of thrust blocks and illustrations of all thrust block configurations required in the system 6. Manufacturer's specifications for the irrigation pump, traveler and sprinkler(s). 7. Manufacturer's specifications for the irrigation pipe and/or USDA-NRCS standard for IRRIGATION WATER CONVEYANCE. 8. The information required by this form are the minimum requirements. It is the responsibility of the designer to consider all relevant factors at a particular site and address them as appropriate. 9. Irrigation pipes should not be installed in lagoon or storage pond embankments without the approval of the designer. NOTE: A buffer strip of 25' or wider must be maintained between the limits of the irrigation system and all perennial streams and surface waters per NC Statutes. Sheet6 Narrative of Irrigation System Operation This design dated 9/19/2023 is for an addition of a center pivot to an existing facility. The acres were comput calculated based on the equipment specified. Maps drawn by Jim Blanchard Associates, P.C. Pivot 1 replaces pulls 6-9 and 12-19. Remaining pulls and application areas of the fields will be applied to with previous existing equipment. Refer to owner's manual and irrigation dealer for information on maintenance, winterization, and operation of system. This design dated 3/14/2024 done to reflect the addition of a digester and the removal of pull 5. All other parameters remained the same. Sheet? CALCULATIONS Sprinkler Specifications Sprinkler Type: Nelson 150 Nozzle Size: 0.86 inches Sprinkler Pressure: 60 psi Flowrate(GPM): 110 gpm Wetted Diameter: 260 feet Lane Snacinus Desired Spacing (%): 70 % Design Spacing(feet): 182 *PVC irrigation pipe normally comes in 20' pieces, so round to the nearest multiple of 20. Actual Spacing (feet): 180 feet Actual Spacing (%): 69 % Application Rate Application Rate =(96.3xFlowrate)/(3.1415x(.9xradius)squared) Design App. Rate = 0.25 in/hr 300 degree arc = 0.30 in/hr 330 degree arc = 0.27 in/hr 220 degree arc = 0.40 in/hr 180 degree arc = 0.49 in/hr Traveller Speed - Travel speed = 1.605 x Flowrate / Desired application amount x Lane Spacing Desired app. (in.) = 0.5 inches 360 degree arc = 1.96 ft/min 300 degree arc = 2.35 ft/min 330 degree arc = 2.14 ft/min 220 degree arc = 3.14 ft/min 180 degree arc = 3.92 ft/min Mainline Velocity Velocity = .408 x Flowrate / pipe diameter squared feet/sec.** **For buried pipelines, velocity should be below 5 feet per second Pipe size: inches Velocity= #DIV/0! ft/sec. Page 1 Sheet7 (3) CALCULATIONS Pivot/Linear Specifications Pivot 1 Pivot/Linear Type: Pivot Machine Length: 784 (feet) End Gun Radius Base Pressure: psi Pipe Diameter: Flowrate(GPM): 0 gpm Machine Flow: Wetted Length: 884 feet End Gun Flow: Application Rate See Manufacturers Specifications Sheet Travel Speed See Manufacturers Specifications Sheet Mainline Velocit 100 (feet) (inches) gpm gpm Velocity = .408 x Flowrate / pipe diameter squared feet/sec.** **For buried pipelines, velocity should be below 5 feet per second Pipe size: 6 inches Velocity= 0.00 ft/sec. Maximum Mainline Friction Loss Most distant hydrant: Total distance: feet Friction Loss is figured using Hazen/William's Equation Friction Loss= 0.00 feet/100 feet Max. Mainline Loss = 0.0 feet or 0.0 psi Maximum Machine Friction Loss Friction Loss is figured using HazenMilliam's Equation Friction Loss= #DIV/0! feet/100 feet Max. Mainline Loss = #DIV/0! feet or #DIV/0! psi Page 1 CDP Farm AWS310557 Pivot Add t. Digester Add t. NOTE Pivot replaces existing puts 6-9 do 12-19. The remaining acres in the field dap with exbzting pulls 10-11 will be aWIW to via an aarwray (Ilsted as Aer-y 0). o Total Field = 61.27 Ac. y Wetted = 35.20 Ac. Aerway 23 = 26.07 Ac. Pivot 29.00 Ac. w/o End Gun 35.20 Ac. w/End Gun Machine Runs 236 Degrees End Gun Runs 185 Degrees Machine Length = 784' End Gun Radius = 100' ---------------------- 4.90 Ac. Ditch to be filled in Lagoon Lagoon i� a 3 2 NOTE: Pull 5 was removed due to 4 the location of the digester. The remaining pulls 1-4 are shown as they were from previous determinations. ci No recalculations were done. Digester o Q Q � M n ►� raj O O � aF M N 400 0 200 400 Boa I ( IN FEET ) 1 inch = 400 ft~