Loading...
HomeMy WebLinkAbout820096_Structural Evaluation_202401030 Division of Water Resources ❑ Division of Soil and Water Conservation ❑ Other Agency Facility Number: 820096 Facility Status: Active Permit: AWS820096 ❑ Denied Access Inspection Type: Structure Evaluation Inactive Or Closed Date: Reason for Visit: Follow-up County: Sampson Region: Fayetteville Date of Visit: 01/03/2023 Entry Time: 10:30 am Exit Time: 11:40 am Incident #: Farm Name: Michael Matthis Farm Owner Email: mikematthis@gmail.com Owner: Michael Monroe Matthis Phone: 910-990-9610 Mailing Address: 181 Union School Rd Clinton NC 28328 Physical Address: 8009 Taylors Ridge Rd Clinton NC 28328 Facility Status: ❑ Compliant 0 Not Compliant Integrator: Murphy -Brown LLC Location of Farm: Latitude: 34' 51' 27" Longitude: 78' 15' 33" East of US 421, 11 miles S. of Clinton. Just south of Edmond Matthids Rd (SR 1004) and north of rest stop. Farm sign for 4902. No office on farm. Question Areas: Waste Col, Stor, & Treat Other Issues Certified Operator: Michael Monroe Matthis Operator Certification Number: 1007363 Secondary OIC(s): On -Site Representative(s): Name Title Phone 24 hour contact name Monroe Matthis On -site representative Monroe Matthis Primary Inspector: Steve Guyton Phone: Inspector Signature: Date: Secondary Inspector(s): Diane Harrison Katie Fontenot Inspection Summary: DWR went on site to survey the lagoon because the lagoon marker seemed to be off, the lagoon appeared to be much higher then what the marker is reading. The marker was showing 14.5 inches, and after DWR surved we determeined the freeboard marker is off by 8 incehs so the lagoon level is actualy 6.5 inches. Michael is getting a 5 day POA in place since he is actually in structure and is going to pump his lagoon down today. DWR will follow up on the status of the lagoon. This farm has no pigs and no current contract to have pigs. Page 1 of 2 Permit: AWS82009E Owner: Michael Monroe Matthis Facility Number: 820096 Inspection Date:01/03/23 Inspection TypeStructure Evaluation Reason for Visit:Follow-up Waste Structures Effective Built Closed Designated Observed Type Identifier Date Date Date Freeboard Freeboard Lagoon 1 05/03/2006 31/01/1993 19.00 14.50 Waste Collection, Storage & Treatment 4. Is storage capacity less than adequate? If yes, is waste level into structural freeboard? 5. Are there any immediate threats to the integrity of any of the structures observed (Led larc trees, severe erosion, seepage, etc.)? 6. Are there structures on -site that are not properly addressed and/or managed through a waste management or closure plan? 7. Do any of the structures need maintenance or improvement? 8. Do any of the structures lack adequate markers as required by the permit? (Not applicablE to roofed pits, dry stacks and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require maintenance or improvement? Other Issues 28. Did the facility fail to properly dispose of dead animals within 24 hours and/or document and report mortality rates that exceed normal rates? 29. At the time of the inspection did the facility pose an odor or air quality concern? If yes, contact a regional Air Quality representative immediately. 30. Did the facility fail to notify regional DWQ of emergency situations as required by Permit, (i.e., discharge, freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? If yes, check the appropriate box below. Application Field Lagoon / Storage Pond Other If Other, please specify 32. Were any additional problems noted which cause non-compliance of the Permit or CAW M P? 33. Did the Reviewer/Inspector fail to discuss review/inspection with on -site representative? 34. Does the facility require a follow-up visit by same agency? Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Page 2 of 2