Loading...
HomeMy WebLinkAboutNCG240023_NOI Inspection Report_20240306 Compliance Inspection Report Permit:NCG240023 Effective: Expiration: Owner: Halifax Fertilizer Company Inc SOC: Effective: Expiration: Facility: Halifax Fertilizer Company Inc. County: Halifax 1107 S Dennis St Region: Raleigh Enfield NC 27823 Contact Person:Donald White Title: Phone: 252-445-5174 Directions to Facility: 0.2 miles southwest from the intersection of Plant St. and S. Dennis St. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On-Site Representative(s): Related Permits: Inspection Date: 03/06/2024 Entry Time 01:30PM Exit Time: 02:45PM Primary Inspector:Thaddeus W Valentine Phone: Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Technical Assistance Permit Inspection Type: Compost Operations Stormwater/Wastewater Discharge COC Facility Status: ❑ Compliant ❑ Not Compliant Question Areas: Storm Water (See attachment summary) Page 1 of 4 Permit: NCG240023 Owner-Facility:Halifax Fertilizer Company Inc Inspection Date: 03/06/2024 Inspection Type:Technical Assistance Reason for Visit: Routine Inspection Summary: I spoke with Kerry Dennis, the Plant Manager and he showed me around the site. The facility is still working on additions located on the West side. The facility mixes and packages chemicals for fertilizer sales. There are poly tanks of waste oil stored outside that are requird to be located inside and/or in secondary containment if it meets the size criteria (the storage capacity of the containers, not how much is normally stored in them) The ditch behind the facility has been greatly contaminated by the fertilizer from the facility. More than likely from the area on the railroad tracks where product is delivered.This ditch will be required to be cleaned out and the material properly disposed of once confirmation samples have been taken. Samples should be taken along the ditch until all contamination has been removed.Please provide the report of the cleanup to the office when completed. It should be confirmed that the pipe plug in the ditch has been permanently attached, so it cannot be removed. Review the outfall areas listed in the checklist to determine if one or both should replace the proposed sample point. Page 2 of 4 Permit: NCG240023 Owner-Facility:Halifax Fertilizer Company Inc Inspection Date: 03/06/2024 Inspection Type:Technical Assistance Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ❑ ❑ ❑ #Does the Plan include a General Location (USGS) map? ❑ ❑ ❑ #Does the Plan include a"Narrative Description of Practices"? ❑ ❑ ❑ #Does the Plan include a detailed site map including outfall locations and drainage areas? ❑ ❑ ❑ #Does the Plan include a list of significant spills occurring during the past 3 years? ❑ ❑ ❑ #Has the facility evaluated feasible alternatives to current practices? ❑ ❑ ❑ #Does the facility provide all necessary secondary containment? ❑ ❑ ❑ #Does the Plan include a BMP summary? ❑ ❑ ❑ #Does the Plan include a Spill Prevention and Response Plan (SPRP)? ❑ ❑ ❑ #Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ❑ ❑ ❑ #Does the facility provide and document Employee Training? ❑ ❑ ❑ #Does the Plan include a list of Responsible Party(s)? ❑ ❑ ❑ # Is the Plan reviewed and updated annually? ❑ ❑ ❑ #Does the Plan include a Stormwater Facility Inspection Program? ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ❑ ❑ 0 ❑ Comment: The SP3 has not been developed yet Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring? ❑ 0 ❑ ❑ Comment: no data was reviewed Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ❑ ❑ 0 ❑ #Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ 0 ❑ Comment: No data was reviewed Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ❑ ❑ 0 ❑ #Were all outfalls observed during the inspection? ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ❑ #Has the facility evaluated all illicit(non stormwater)discharges? ❑ ❑ 0 ❑ Comment: The outfall was inspected and it appears the outfall location is for the ditch that runs by the parking lot out to the road that doesn't envolve any industrial activity, but only vehicle parking. There is an outfall located on the NE corner of the facility that would be better suited as an outfall that outlets into a ditch that runs along the back of the property Location- (36/10/15.56,-77/40/40.16)There is a pipe outlet on the SE corner of the facility that drains an area under the railroad tracks, where chemicals are dumped on a conveyor system, that is said to be capped off. That is another possible outfall location (36/10/12.91,-77/40/42.97). Additional comments in summery Page 3 of 4 Permit: NCG240023 Owner-Facility:Halifax Fertilizer Company Inc Inspection Date: 03/06/2024 Inspection Type:Technical Assistance Reason for Visit: Routine Page 4 of 4