HomeMy WebLinkAbout310017_Add-Info Response_20220418April 14, 2022 Christine Lawson NCDEQ Division of Water Resources 1601 Mail Service Center Raleigh, NC 27699-1601 Subject: Response to Additional Information Request Application No. AWS310017/AW1310017 DM Farms Sec 2 Sites 1-4 CAVANAU G H Stewardship Through Innovation Modification to Swine Digester Animal Waste Management System Dear Ms. Lawson, Cavanaugh & Associates, P.A., on behalf of the permittee, has reviewed your comments dated April 8, 2022 for the permit modification for the subject facility, and has developed responses and additional supporting information to address each item in your comments. For your convenience, we have repeated the comments below in bold font, followed by the responses in italicized font. 1. Permit Type Requested — Please clarify if the proposed modification is requested under the current Individual Permit or General Permit. Are you requesting rescission of the alternate permit? Do you wish to withdraw the AW1310017 renewal application received September 10, 2021? Response: The permittee, and applicant, wishes to proceed with a permit modification under the General Permit, and upon issuance of the updated Certificate of Coverage under the General Permit, proceed with recission of the Alternate Permit and withdrawal of the renewal application received September 10, 2021. 2. Liner design information — Please provide all available design information for the existing earthen liner for the proposed Digesters A and B (lagoons 2-2 and 2-3, respectively). Response: All available liner design information for the existing earthen liner has been included with this response. The liner design information was provided with the necessary liner certification documentation upon completion of construction, in or around 1995, and has been accepted as having been provided as required in each subsequent permit renewal by the Division, de facto. The applicant is unable to locate copies of the original design document used over twenty-five years ago, but is confident that the information regarding the liner was found to have been acceptable by the Division now through numerous permit renewals. 3. Land Application/Irrigation Map — Please provide a land application/irrigation map that aligns with the Waste Utilization Plan. Response: Please see additional map information included with this response. Page 1 of 3 4. Watershed Classification Map —The Watershed Classification Map submitted shows the location of a proposed NEW digester that is not indicated anywhere else in the application package. Please clarify. Response: Please see revised Watershed Classification Map included with this response. 5. Design Volumes/Calculations —The design volumes shown for Lagoon 2-2 (Digester A) and Lagoon 2-3 (Digester B) are the same. The (West) Volume Calculations sheet shows Digester A (lagoon "2- 2") in the table heading. The (East) Volume Calculations sheet shows Digester A (;lagoon "2-3") in the table heading. The data in both tables are identical; however, the site plan clearly shows that the two lagoons are not identical in construction. Please provide clarification regarding the discrepancy, particularly for the Digester Volume Calculations which might better be based on the as -built designs. Response: The volume calculations for Lagoon '2-3'should refer to Digester B instead of Digester A; the typos have been corrected and revised and corrected calculations are submitted with this response. That being said, the volume calculations correctly use the dimensions given from the original lagoon designs; Lagoon '2-2' was approved by Neal Tucker on 1994-10-27 and gives lagoon dimensions of 500'x450'x11 ' and Lagoon '2-3' was approved by Neal Tucker on 1994-10- 27 and gives lagoon dimensions of 500'x450'x11' (the some date and reviewer as Lagoon '2-2') . 6. Tank Digesters — Please describe how existing tank digesters will be used, decommissioned or officially closed. Response: The existing tank digesters will be emptied of their contents and will not continue to receive manure or be used for the anaerobic digestion of manure upon placing the proposed covered in - ground digesters into service. The tanks will remain in place and will not be demolished, but will not be physically connected to the manure piping system (air gap installed). ). The permittee desires the tanks to remain in the permit for effluent storage that can be used in extreme weather or emergency situations. 7. Operation & Maintenance —Contact Information —The contact information you have listed for me is out of date, by some years. My current phone number is 919-707-3664. Please verify that information for all contacts is accurate and update the O&M Contact List. Response: Please see updated Appendix A of the Operation & Maintenance Plan, with updated and current contact information included, included with this response. 8. Stormwater Outlet —Please provide atypical detail for outlet for stormwater removed from digester cover. Please also indicate location. Response: Please see Stormwater outlet detail included with this response. It should be noted that the design low point in the lagoon cover will be determined by the cover supplier/installer, and provided to the permittee as a submittal drawing prior to installation. Therefore, the specific Page 2 of 3 location depicted in the detail provided may change; and if so, such change will be reflected in the record drawings upon completion of construction. 9. Gas Utilization — Please provide information for the intended onsite and/or offsite use of the biogas. The current designated use is electrical generation. If this is not the case, please provide information regarding the decommissioning of generator and gas conditioning equipment. Response: At this time, the applicant has no specified nor contracted on -site nor off -site use of the biogas. In the interim, the biogas will be vented to atmosphere. 10. Clarification of Flare Model — Please verify that a separate flare will be kept on -site for use for each digester — a total of two. Where will these flares be stored? Will they be tested periodically? Response: A candlestick flare will be kept on site, at a location that is protected and chosen by the farm owner based on ready accessibility, for use at each digester. There are no plans nor need to test the flare on any regular basis, as the biogas will be vented to atmosphere should accumulated biogas be stored for any extended duration. 11. Gas Generation Estimate — Please submit an estimate for the daily volume of biogas to be generated by the proposed Digester. Response: The daily volume of biogas varies based on animal stocking numbers, animal age, and climatic variations; is considered confidential business information by the applicant, and we are unable to find reference to the requirements for providing biogas generation estimates when seeking a modification to the Permit of the subject facility. If our interpretation is in error, please provide the reference to the applicable rule or statute. Thank you for your continued efforts to review this permit application and supporting information. Please do not hesitate to contact our office should you have any questions, comments, or require any additional information. Regards, Cavanaugh & Associates, P.A. illiam G. Simmons, Jr., P. Attachments cc: Ironside Investment Management, LLC, via AJ Linton Jeff P. Cappadona, P.E., Cavanaugh & Associates, P.A. Page 3 of 3 1 n 75, 1 . 1 A� II ' 41 6 (#2) UNNAMED TRIBUTARY TO MURPHEYS CREEK EX. 0 (#1) UNNAMED LAGOON TRIBUTARY TO O MURPHEYS CREEK 0 EX. LAGOON 1%7 c:::3 C=:3 O O 0 EX. O LAGOON SEC 2 FARMS \ ' 0 EX. 0 LAGOON O O O r �I (� (#3) UNNAMED EXISTING \ \ TRIBUTARY TO LAGOONS TO MURPHEYS CREEK BE CONVERTED TO ANAEROBIC DIGESTER NAME OF STREAM ISTREAM CLASS STREAM INDEX 1 UT TO MURPHEYS CREEK C; Sw 18-74-29-0.5 2 UT TO MURPHEYS CREEK C; Sw 18-74-29-0.5 LATITUDE: 34°52'04.0"N LONGITUDE: 78°09'06.80"W �� WATERSHED CLASSIFICATION MAP BF GRADY BIOGAS COLLECTION DM FARMS SEC 2—SITES 1-4 OWNER: IRONSIDE INVESTMENT MGMNT, LLC CAVANAUGH Stewardship through innovation LOCATION NOT TO SCALE Cavanaugh & Associates, P.A. 1213 Culbreth Dr. Wilmington, NC 28403 (910) 392-4462 Fax: (910) 392-4612 www.cavanaughsolutions.com PROJECT if: BE19.006 DRAWN BY: LJL BD 1: SCALE: 1"=600' 1 DATE: 2020-03 REVISION 1.0 -APRIL 14, 2022 CORRECTED NOTATION OF CONVERSION OF EXISTING LAGOONS TO ANAEROBIC DIGESTER; REMOVED PROPOSED NEW DIGESTER DM Farms Sec 2 Sites 1-4 (East) Volume Calculations Project: Project No Date: DM Farms Sec 2 Sites 1-4 (East) Location: Duplin & Sampson County, NC BE.19.006 Client: Smithfield 2021-9-23 Freeboard Elevation Digester Required Volume: Digester Design Volume (@ freeboard): % Required: Di ester B Volume (Lagoon '2-3' Elevation ft Area sf Incr. Vol cf Cumul. Vol cf 27.00 166,656 - - 28.00 171,600 169,128 169,128 29.00 176,616 174,108 343,236 30.00 181,704 179,160 522,396 31.00 186,864 184,284 706,680 32.00 192,096 189,480 896,160 33.00 197,400 194,748 1,090,908 34.00 202,776 200,088 1,290,996 35.00 208,224 205,500 1,496,496 36.00 213,744 210,984 1,707,480 37.00 219,336 216,540 1,924,020 38.00 225,000 222,168 2,146,188 506,160 cu ft. 1,707,480 cu ft. 337% %. H Design By: JPC Checked By: WGS Note: The dimensions and volumes shown are provided based on the lagoon design for the '2- 3' lagoon, approved by Neal Tucker on 1994-10- 27 1 of 2 Overall Farm Volumes: (cu.ft.) Treatment Excess Wash Water Rainfall in excess of evaporation Storm Storage Daily Inflow Total 4 CAVANAU G H Stewardship Through Innovation Existing Configuration Existing Lagoon '2-3' Existing Lagoon '2-4' Vol. Required` Vol. Provided" Efficiency Vol. Required` Vol. Provided" Efficiency 1,069,200 1,069,200 100% 1,069,200 1,069,200 100% 171,529 171,529 100% 0 0 N/A 156,737 156,737 100% 149,042 149,042 100% 167,933 167,933 100% 153,301 153,301 100% 261,106 358,561 137% 261,106 436,017 167% 1,826,505 1,923,960 105% 1,632,649 1,807,560 1 111% Note: The existing volumes shown above are provided based on the lagoon calculations for this farm, approved by Neal Tucker on 1994-10-27 Note: The existing volumes shown above are provided based on the lagoon calculations for this farm, approved by Neal Tucker on 1994-9-25 Total Required 2,138,400 171,529 305,779 321,234 522,212 3,459,154 Proposed Configuration (Digester + Storage Lagoon) Volume Required* Volume Provided* Digester B (i.e. '2-3') Existing Lagoon '2-4' otaDigester Required B (i.e. '2-3') Existing Lagoon '2-4' I ota Provided Efficiency Treatment 1,069,200 1,069,200 2,138,400 1,707,480 430,920 2,138,400 100% Excess Wash Water 171,529 0 171,529 0 171,529 171,529 100% Rainfall in excess of evaporation 0 149,042 149,042 0 149,042 149,042 100% Storm Storage 0 153,301 153,301 0 153,301 153,301 100% Daily Inflow 261,106 1 261,106 1 522,212 1 0 1 902,768 1 902,768 1 173% Total 1,501,835 1 1,632,649 13,134,4841 1,707,480 1 1,807,560 1 3,515,040 1 112% Total Required Temporary Storage: Existing Proposed Excess Wash Water 171,529 171,529 Rainfall in excess of evaporation 305,779 149,042 Daily Inflow 522,212 522,212 Total 999,520 842,783 Days of Storage: Existing Lagoon'2-4' Revised Elevations: Zone Volume I Cumulative Vol. I Elevation Treatment 430,9201 430,920 83.67 Temporary 1,223,339 1,654,259 90.26 Storm 153,301 1,807,560 91.00 of Dike Elev = 92 Top of Storm Elev = 91 (1807560 cf) Top of Temp Storage Elev = 90.26 (1654259 cf) (Start Pump) Top of Treat Elev = 83.67 (430920 cf) (Stop Pump) Finished Bottom Elev = 81 Note: Elevations and volumes are based on the same datum and sizing information as the lagoon calculations for this farm, approved by Neal Tucker on 1994-9-25 2 of 2 Appendix A: Contact Information Project Management and Equipment Service Providers: Management & Equipment CompanyProject Contact/Local Service Influent Pump Station Lee Brock Brock Equipment Company lee@ brockeguipment.com (252) 235-4111 Anaerobic Digester Cover Plastic Fusion Fabricators, Inc. Larry Hice Ihice@plasticfusion.com (256) 852-0378 Mixing Pump Station Lee Brock Brock Equipment Company lee@ brockeguipment.com (252) 235-4111 Transfer Pump Lee Brock Brock Equipment Company lee@brockeguipment.com (252) 235-4111 Flare ProPump & Controls Inc. Jeff McGuire Work: (843) 236-3996 Cell: (704) 658-8113 imcguire@propumpservice.com Mechanical Installation & Controls (Biogas) ProPump & Controls Inc. Jeff McGuire Work: (843) 236-3996 Cell: (704) 658-8113 imcguire@propumpservice.com Mechanical Installation & Controls (Manure Murphy Family Ventures, LLC collection, Digester, Effluent, & Irrigation) Dan Best Self -Performed by Permittee Cell: 910-271-0362 dbest@murfam.com Anaerobic Digester System O&M Page 13 of 16 Regulatory and other Agencies: MOP Location Christine Blanton Lawson DWQ, AFO Permitting Raleigh, NC and Compliance (919) 707-3664 Anaerobic Digester System O&M Page 14 of 16 ���`�-��'✓ 1111 `t e..�✓' � �> > �1 y0r ^�, '1/1�F�7 �t..:'Y.4 "( `Y� iFlJz"�"i�-�y—�����i t :':k:•a` o. d IP5-2e INV w.�: .y STORMWATER DRAIN PIPE & OUTLET M1T t ! 1 1 •� .� (EXISTING) c PROTECTION Nt1 1 9 1 1. qry}e r^ ...y _ _ �...�1 �(1.el1 •� a rd ,I ii ifs �.'M1 •`1i N. i r•� i 1.1 �• v IPS-3B EXISTING LAGOON �2-2' _ �rC PIPE TO BE CONVERTED TO / q"'a (EXISTING) ANAEROBIC DIGESTER-_.ro _ tis •� TOP OF DIKE 137.00'_ IPSING) INV (EXIEXISTING FREEBOARD 136.00' '� ST}. NEW FREEBOARD 13500' e JFFE 14000t l o z zz, 0 11iIr� a�Ly J:'n i! EFE 14000 - �zm� { I111{�-1v cl\ 1 a,, �. a`T• FE 14000' '4 �/ r.1., .. _. �i-r%,.�', i ,.,. ,.,. N� �'C 01111 �1�,�_-.,..�-n-%,�••�f .,. r(, LOCATION MAP 2 SCALE: NOT TO SCALE B jDl DRAIN PIPE SHALL BE 4" CORR. HDPE OR EQUIVALENT. STORMWATER DRAIN SHALL HAVE MIN. 0.25% SLOPE. DRAIN LOCATION SHOWN AS APPROXIMATE. EXACT DRAIN PUMP LOCATION AND OUTLET TO BE DETERMINED UPON RECEIPT AND APPROVAL OF COVER SUBMITTALS. OUTLET SHALL EXTEND MIN 10' BEYOND OUTSIDE TOE OF DIKE. LACE WASHED TONE AROUND IPE AS DIRECTED Y THE ENGINEER EQUAL MAINTENANCE INSPECT OUTLET STRUCTURES WEEKLY AND AFTER SIGNIFICANT (1" OR GREATER) RAINFALL EVENTS TO SEE IF ANY EROSION AROUND OR BELOW THE OUTLET HAS TAKEN PLACE, OR IF STONES HAVE BEEN DISLODGED. IMMEDIATELY MAKE ALL NEEDED REPAIRS TO PREVENT FURTHER DAMAGE. OUTLET PROTECTION 1 SCALE: NOT TO SCALE B D 1 STORMWATER OUTLET DETAIL PROJECT #: BE.19.0G. DRAWN BY: WGS ON -FARM DM FARMS B I O G A S SEC 2 SYSTEM SITES 1- 4; 2-2 CAVANAU G H Solutions through integrity and partnership BD1 D U P L I N & SAMPSON COUNTY, NC Cavanaugh & Associates, P.A. PO Box 11197 Winston3alem, N0 gh1 l 1-871-551-8923 wwwca .vanaughsolutions.com DATE: 4/14/2022 �v = 1 ill/gllriil \ti/ s� ltJd!/f Jllr`\\\, 1�`',. �'vRQ�\--"'� �'� STORMWATER DRAIN PIPE&OUTLET i 7fll�l����v'—�—� _— l� �L�� i6'• z'��: PROTECTION ���1VA r�i V 1 VA��A I "si rrV111s 1� l FEE 130.00' Yt` \ 111lII(11 1S lIlY r � Tull.,✓' \ Yt lr),rlr ,,�\I/ FFE 130.00,1;./•� \ \ 1 (EXISTING LAGOON '2-3' ' _ l\\ \\ II IVIVr/f TO BE CONVERTED TO / )ANAEROBIC DIGESTER TOP OF DIKE 119.00• FEE 130. "', it l \\ III I I EXISTING FREEBOARD 118.00' NEW FREEBOARD 117.00' ll FEE 130.00' tl\ 'FFE 130_DD' Y/ III"IIUI�lI� 'IPs-4D J r` r/I PIPE r / o1j (EXISTING) f//!)/// /1 !/ r lv /{ / ! J! g� IPS-2D + I(l/ //j fl f IPS-1C .J SI{ ! (EXISTING) l . i•�y�l S\. /! Y (EXISTING .. .� j/ilf/1)!!I ! t t I'WET WELL +1 ! rrl//f1)/%l1/j 1f/ I) I��\ r. \ 1t /1 _ l�//ii/lil +f / J'' � 1 > l 1 rr / � /r' � � �•.. t` � . b{lrf .i ] LOCATION MAP r2 SCALE: NOT TO SCALE B D 1 NOTES: 1. DRAIN PIPE SHALL BE 4" CORR. HDPE OR EQUIVALENT. 2. STORMWATER DRAIN SHALL HAVE MIN. 0.25% SLOPE. 3. DRAIN LOCATION SHOWN AS APPROXIMATE. EXACT DRAIN PUMP LOCATION AND OUTLET TO BE DETERMINED UPON RECEIPT AND APPROVAL OF COVER SUBMITTALS. 4. OUTLET SHALL EXTEND MIN 10' BEYOND OUTSIDE TOE OF DIKE. LACE WASHED TONE AROUND IPE AS DIRECTED Y THE ENGINEER #57 WASHED STONE, 2" THICK MAINTENANCE INSPECT OUTLET STRUCTURES WEEKLY AND AFTER SIGNIFICANT (1" OR GREATER) RAINFALL EVENTS TO SEE IF ANY EROSION AROUND OR BELOW THE OUTLET HAS TAKEN PLACE, OR IF STONES HAVE BEEN DISLODGED. IMMEDIATELY MAKE ALL NEEDED REPAIRS TO PREVENT FURTHER DAMAGE. OUTLET PROTECTION1 SCALE: NOT TO SCALE B D 1 2:1 SLOPE MIRAFI 50OX FILTER FABRIC OR APPROVED EQUAL STORMWATER OUTLET DETAIL PROJECT# BE19.002 DRAWN BY: WGS ON —FARM DM FARMS B I O G A S SEC 2 SYSTEM SITES 1-4; 2-3 CAVANAU G H Solutions through integrity and partnership �` BD1 D U P L I N & SAMPSON COUNTY 7 NC Cavanaugcia h & Assotes, P.A. PO Box 11197 Winston-Salem• N0gh1 1 1-877-551-8923 www._anaughsolutions.com DATE: 4/14/2022