Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NC0083887_Monitoring (Report)_20231017
October 12, 2023 Mr. James P. McDorman, P.G. Environmental Compliance Coordinator Charlotte Douglas International Airport 5601 Wilkinson Boulevard Charlotte, North Carolina 28208 Subject: Surface Water Sampling and Analysis Report (Third Quarter) Former U.S. Airways Maintenance Hangar NCDEQ UST Section Incident No. 14908 5020 Hangar Road Charlotte, North Carolina WSP Project: 6228-21-0061 Dear Mr. McDorman: WSP USA Environment & Infrastructure Inc. (WSP) is pleased to submit this Surface Water Sampling and Analysis Report for the above -referenced property in Charlotte, North Carolina. Included in this report is an outline of our understanding of the project background, description of the sampling activities and results. Project Background U.S. Airways, Inc. (U.S. Airways) previously operated an aircraft jet fuel defueling/refueling system at the former U.S. Airways Maintenance Hangar located at 5020 Hangar Road in Charlotte, North Carolina. The site is located in the southwest portion of the Charlotte/Douglas International Airport property (Tax Parcel ID 115-211-05). American Airlines (formerly U.S. Airways) currently leases the maintenance hangar facility from the City of Charlotte and performs aircraft maintenance at the property. A 1995 release of petroleum occurred at the hangar location. In December 2018, CLT personnel observed evidence of petroleum seepage from the bank of Coffey Creek approximately 800 feet north of contaminant source area (Figure 1). In email correspondence, dated May 13, 2021, Mr. James McDorman informed WSP personnel that Mr. Wes Bell of the North Carolina Department of Environmental Quality (NCDEQ), Division of Water Resources (DWR) requested performance of quarterly surface water sampling and analysis of Coffey Creek to assess whether dissolved petroleum hydrocarbons are present in the stream. Surface Water Sampling and Analysis On September 27, 2023, WSP personnel collected one surface water sample (SW-01) from Coffey Creek. The sample was collected using a stainless -steel cup attached to a stainless -steel rod. This device allows for the water WSP USA Environment & Infrastructure Solutions Inc. 2801 Yorkmont Road, Suite 100 Charlotte, North Carolina 28208 NC Geology License: C-247 T: 704-417-5152 Surface Water Sampling and Analysis Report Former U.S. Airways Maintenance Hangar WSP Project: 6228-21-0061 October 12, 2023 sample to be dipped from near the center of the stream by the sampler. The sampling cup was decontaminated prior to use by rinsing with isopropyl alcohol, followed by distilled water. Sample SW-01 was collected approximately 20 feet downstream of the last petroleum absorbent boom. The location is shown on Figure 1. The collected sample was poured into laboratory -provided containers with appropriate preservatives. The sample containers were placed in an ice -filled sample cooler and delivered to Waypoint Analytical, LLC (Waypoint) in Charlotte, North Carolina for analysis. The sample was maintained under chain -of -custody protocol. The laboratory analyzed the surface water sample for volatile organic compounds (VOCs) by EPA Method 6200B including MTBE and semi -volatile organic compounds (SVOCs) by EPA Method 625.1. Results The results of the analyses of sample SW-01 identified detectable concentrations of chrysene, dibenz(a,h)anthracene, and indeno(1,2,3-cd)pyrene. Chrysene is not typically associated with jet fuel, but is produced as a byproduct of incomplete combustion of coal and gasoline, and was identified in the surface water sample at a concentration of 2.07 µg/L. This concentration of chrysene exceeded the NCAC 2B Standard for Total Polynuclear Aromatic Hydrocarbons (PAHs) of 0.0311 µg/L (Class C: Fish Consumption). Indeno(1,2,3-cd)pyrene and dibenz(a,h)anthracene are not typically found in jet fuel but are common oxygenated compounds in gasoline and diesel exhaust. Indeno(1,2,3-cd)pyrene was identified in the surface water sample at concentration of 2.12 µg/L, which exceeded the NCAC 2B Standard for Total PAHs of 0.0311 µg/L (Class C: Fish Consumption). Dibenz(a,h)anthracene was identified in the surface water sample at concentration of 2.28 µg/L, and did not exceed the NCAC 2B Standard for In Stream Target Values related to Aquatic Life and Secondary Recreation of 5 µg/L (Class C). It is WSP's opinion that the presence of chrysene, dibenz(a,h)anthracene, and indeno(1,2,3- cd)pyrene is likely not related to the contaminants (i.e. jet fuel) known to be present upgradient of Coffey Creek. Certain constituents were identified at concentrations that are considered "estimated" (noted with a "J" on Table 1) because they were identified at a level above the Method Detection Limit (MDL), but below the Reporting Limit (RL). These included benzo(a)anthracene, benzo(a)pyrene, benzo(g,h,i)perylene, and benzo(k)fluoranthene, which are also not typically found in jet fuel. The laboratory report is attached. The next surface water sampling event is planned for December 2023. Surface Water Sampling and Analysis Report Former U.S. Airways Maintenance Hangar WSP Project: 6228-21-0061 Closing October 12, 2023 We appreciate your selection of WSP for this project and look forward to assisting you further on this project. If you have questions, please contact us. Sincerely, WSP USA Environment & Infrastructure Inc. A5�11-z--I-�i�----� Robert Baker Robert C. Foster, L.G. Tech Professional 1 Geologist Registered, NC #1335 Cc: Mr. Wes Bell, Senior Environmental Specialist, NCDEQ Division of Water Resource �ENSEs <,y Mr. Dan Bowser, LG, Hydrogeologist, NCDEQ-DWM; UST Section �_ S L P� 1336 `'RT C. FaS�• Enclosures Surface Water Sampling and Analysis Report Former U.S. Airways Maintenance Hangar WSP Project: 6228-21-0061 TABLE October 12, 2023 Table 1 Summary of Surface Water Analytical Results Charlotte Douglas International Airport Former U.S. Airways Maintenance Hangar WSP Project No. 6228-21-0061 Analytical Method SVOCs by EPA 625.1 VOCs by Method 6200E T T c Contaminant of Concern m SL — _ �". P o o 0 0 0 o 0 a 0 _ w ° o ° w m _ ~ E a m o o LL i o 0 o N w —5 i Approximate Distance from Sample Date ID Sampled Source Stream Bank LNAPL Seepage (feet) Petroleum SW-01 09/27/23 Seep to 200 -0.302 <0.297 1.82 J 1.54 J <2A9 2.80 J 2.03 J 2.07 2.28 <0.250 <0.807 2.12 <0.728 <0.180 <0.190 <0.220 <0.190 <0.210 <0.500 <0.170 <0.180 <0.140 0.470 <0.220 <0.420 <0.210 Coffrey Creek NC 2B Standard or EPA National Criteria (µ /1) 1 60 1 NE 0.1 1 0.05 0.0311- 0.0311* 0.0311* 0.0311* 5 1 0.11 1 30 0.0311* 1 12 1 51* 1 140 1 470 1 390 1 100 1 20,000 97 250 34,000 12 11 420 600 Notes Prepared by: RJB 10/9/23 1. Concentrations shown in micrograms per liter(pg/1) Reviewed by RCF 10-11-2023 2. < value represents no laboratory detection above the Reporting Limit 3. Bold values exceeded North Carolina 15A 2B Water Quality Standards or Surface Waters INC 2B) /North Carolina In -Stream Target Values, July 2021 4. If the NC 2B Standard was not established for a constituent, North Carolina In -Stream Target Values were used in place 5. NE = Not Established 6. * - 15A NCAC 2B and North Carolina In -Stream Target Values Fresh Water Aquatic life values were not listed, 15A NCAC 2B Human Health values for total PAHs 7. VOCs = Volatile Organic Compounds & SVOCs - Semi -Volatile Organic Compounds Surface Water Sampling and Analysis Report Former U.S. Airways Maintenance Hangar WSP Project: 6228-21-0061 FIGURE October 12, 2023 r � Former Oil Seep Location h Legend MW,• *.' »4�,� ,, ,.;w : t... • . i°2�" t ` ��K • # MW 3 Approximate location of "1 MW-9'I ry r MW 8. MW-6 groundwater monitoring well AF Approximate Surface Water . . `F,i., .*,i � „�! , c., rr „ � Y dir +t � � „1 ,•j Sample Location Creeks/Streams tt { 4 MW-1' 0 * 4 Ab 4 ,.: ... 4": /1 Free Product +? �• T Recovery Tank x rr Ali I blow 1 PMW 17 ♦ Nit RW-4 4 {' N I ► RW-5 RW-7 RW-1 fi `s( �' ,:. �. "° o►�. ''" DFL-1 PMW-16 MW-4 ` 0 50 100 200 r4 PMW-18 Feet } j S FORMER US AIRWAYS Nq r Y FA MAINTENANCE o CE HANGAR ' 1Greensbo North Carolina reenville a + A. a i � '� � > Service Layer Credits Mecklenburg County GIS Aerial Imaclery 202�2 Columbia Title: Date: Projection: Figure: " WSP USA 10/12/2023 Environment &Infrastructure Inc. SITE PLAN NC State Plane (NAD83, feet) Note: This map is for FORMER U.S. AIRWAYS 2801 Yorkmont Road, Suite 100 reference only. MAINTENANCE HANGAR Project No: File: Charlotte, NC 28208 (704) 357-8600 CHARLOTTE, NORTH CAROLINA 6228-21-0061 Xs\AM SCLT500ts\201f- g is\AM EC_Projec[s\2019\6228-19-0619\GIS\ W orki ng Data\ Wo rki n g Data. ap rx -abarrus County Government, Esri, HERE, Garmin, FAO, NOAA, USGS, EPA, Esri, USGS 2021 Drawn hv- KNS - Checked hv- RCF - Date- 10/12/2023 Surface Water Sampling and Analysis Report Former U.S. Airways Maintenance Hangar WSP Project: 6228-21-0061 ATTACHMENT LABORATORY ANALYTICAL REPORT AND CHAIN -OF -CUSTODY FORM October 12, 2023 Waypointo ANALYTICAL 10/6/2023 WSP USA Envi. & Infrastructure Inc. (Charlotte) Rob Foster 2801 Yorkmont Rd. #100 Charlotte, NC, 28208 Ref: Analytical Testing Lab Report Number: 23-270-0016 Client Project Description: CDIA Project #6228-21-0061.09 Dear Rob Foster: 449 5pringbrook Rd, Charlotte, NC 28217 Main 704.529.6364 www.waypointanalytical.com Waypoint Analytical, LLC (Charlotte) received sample(s) on 9/27/2023 for the analyses presented in the following report. The above referenced project has been analyzed per your instructions. The analyses were performed in accordance with the applicable analytical method. The analytical data has been validated using standard quality control measures performed as required by the analytical method. Quality Assurance, method validations, instrumentation maintenance and calibration for all parameters were performed in accordance with guidelines established by the USEPA (including 40 CFR 136 Method Update Rule May 2021) unless otherwise indicated. Certain parameters (chlorine, pH, dissolved oxygen, sulfite...) are required to be analyzed within 15 minutes of sampling. Usually, but not always, any field parameter analyzed at the laboratory is outside of this holding time. Refer to sample analysis time for confirmation of holding time compliance. The results are shown on the attached Report of Analysis(s). Results for solid matrices are reported on an as - received basis unless otherwise indicated. This report shall not be reproduced except in full and relates only to the samples included in this report. Please do not hesitate to contact me or client services if you have any questions or need additional information. Sincerely, Danyale Love Project Manager Laboratory's liability in any claim relating to analyses performed shall be limited to, at laboratory's option, repeating the analysis in question at laboratory's expense, or the refund of the charges paid for performance of said analysis. Page 1 of 26 Waypointo ANALYTICAL 449 5pringbrook Rd, Charlotte, NC 28217 Main 704.529.6364 www.waypointanalytical.com Certification Summary Laboratory ID: WP CNC: Waypoint Analytical Carolina, Inc. (C), Charlotte, NC State Program Lab ID Expiration Date North Carolina State Program 37735 07/31/2024 North Carolina State Program 402 12/31/2023 South Carolina State Program 99012 07/31/2024 South Carolina State Program 99012 12/31/2023 Page 1 of 1 00016/23-270-0016 Page 2 of 26 • Waypoint. (2) 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 ANALYTICAL www.waypointana lyti ca I som Sample Summary Table Report Number: 23-270-0016 Client Project Description: CDIA Project #6228-21-0061.09 Lab No Client Sample ID Matrix Date Collected Date Received 96386 sw-01 Aqueous 09/27/2023 08:30 09/27/2023 12:53 Page 3 of 26 • Waypoint. (2) 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 ANALYTICAL www.waypointana lyti ca I som Summary of Detected Analvtes Project: CDIA Report Number: 23-270-0016 Client Sample ID Lab Sample ID Method Parameters Result Units Report Limit Analyzed Qualifiers SW-01 V 96386 625.1 Benzo(a)anthracene 625.1 Benzo(a)pyrene 625.1 Benzo(q,h,i)perylene 625.1 Benzo(k)fluoranthene 625.1 Chrysene 625.1 Dibenz(a,h)anthracene 625.1 Indeno(1,2,3-cd)pyrene 1.82 pq/L 0.637 10/02/2023 20:15 J 1.54 pq/L 1.02 10/02/2023 20:15 J 2.80 pq/L 1.01 10/02/2023 20:15 J 2.03 pq/L 1.99 10/02/2023 20:15 J 2.07 pq/L 0.405 10/02/2023 20:15 2.28 pq/L 0.434 10/02/2023 20:15 2.12 pq/L 0.477 10/02/2023 20:15 Page 4 of 26 Waypointo ANALYTICAL Client: WSP USA Envi. & Infrastructure Inc. (Charlotte) Project: CDIA Lab Report Number: 23-270-0016 Date: 10/5/2023 449 5pringbrook Rd, Charlotte, NC 28217 Main 704.529.6364 www.waypointanalytical.com CASE NARRATIVE 625.1 - Base/Neutrals and Acids by GC/MS Method 625.1 Analyte: Benzidine QC Batch No: V38587/V38547 Relative Percent Difference (RPD) for the duplicate analysis was outside of the allowable QC limits. Analyte: Dibenz(a,h)anthracene QC Batch No: V38587/V38547 Relative Percent Difference (RPD) for the duplicate analysis was outside of the allowable QC limits. Page 5 of 26 a Wayp��• nt . 0 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 ANALYTICAL www.waypointanalytical.com 01223 WSP USA Envi. & Infrastructure Inc. (Charlotte) Project CDIA Rob Foster Report Date : 10/06/2023 2801 Yorkmont Rd. #100 Information : Project #6228-21-0061.09 Received : 09/27/2023 Charlotte , NC 28208 Report Number : 23-270-0016 REPORT OFANAL YSIS Lab No : 96386 Matrix: Aqueous Sample ID: SW-01 Sampled: 9/27/2023 8:30 Analytical Method: 6200E Prep Batch(es): V38694 10/04/23 09:00 Prep Method: 6200 PT Test Results Units MDL MQL DF Date / Time By Analytical Analyzed Batch Acetone <1.80 Ng/L 1.80 10.0 1 10/04/23 19:03 MSA V38696 Benzene <0.180 N9/L 0.180 0.500 1 10/04/23 19:03 MSA V38696 Bromobenzene <0.210 N9/L 0.210 0.500 1 10/04/23 19:03 MSA V38696 Bromochloromethane <0.420 N9/L 0.420 1.00 1 10/04/23 19:03 MSA V38696 Bromodichloromethane <0.160 N9/L 0.160 0.500 1 10/04/23 19:03 MSA V38696 Bromoform <1.50 N9/L 1.50 5.00 1 10/04/23 19:03 MSA V38696 Bromomethane <0.280 N9/L 0.280 1.00 1 10/04/23 19:03 MSA V38696 n-Butylbenzene <0.180 N9/L 0.180 0.500 1 10/04/23 19:03 MSA V38696 sec -Butyl benzene <0.200 N9/L 0.200 0.500 1 10/04/23 19:03 MSA V38696 tert-Butyl benzene <0.920 N9/L 0.920 2.00 1 10/04/23 19:03 MSA V38696 Carbon Tetrachloride <0.180 N9/L 0.180 0.500 1 10/04/23 19:03 MSA V38696 Chlorobenzene <0.190 N9/L 0.190 0.500 1 10/04/23 19:03 MSA V38696 Chlorodibromomethane <0.190 N9/L 0.190 0.500 1 10/04/23 19:03 MSA V38696 Chloroethane <0.430 N9/L 0.430 1.00 1 10/04/23 19:03 MSA V38696 Chloroform <0.220 N9/L 0.220 0.500 1 10/04/23 19:03 MSA V38696 Chloromethane <0.220 N9/L 0.220 0.500 1 10/04/23 19:03 MSA V38696 2-Chlorotoluene <0.200 N9/L 0.200 0.500 1 10/04/23 19:03 MSA V38696 4-Chlorotoluene <0.200 N9/L 0.200 0.500 1 10/04/23 19:03 MSA V38696 Di -Isopropyl Ether (DIPE) <0.500 N9/L 0.500 0.500 1 10/04/23 19:03 MSA V38696 1,2-Dibromo-3-Chloropropane <1.10 N9/L 1.10 2.00 1 10/04/23 19:03 MSA V38696 1,2-Dibromoethane <0.200 N9/L 0.200 0.500 1 10/04/23 19:03 MSA V38696 Dibromomethane <0.230 N9/L 0.230 0.500 1 10/04/23 19:03 MSA V38696 1,2-Dichlorobenzene <0.220 N9/L 0.220 0.500 1 10/04/23 19:03 MSA V38696 Qualifiers/ DF Dilution Factor J Estimated value Definitions MQL Method Quantitation Limit Page 6 of 26 a Wayp��• nt . 0 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 ANALYTICAL www.waypointanalytical.com 01223 WSP USA Envi. & Infrastructure Inc. (Charlotte) Project CDIA Rob Foster Report Date : 10/06/2023 2801 Yorkmont Rd. #100 Information : Project #6228-21-0061.09 Received : 09/27/2023 Charlotte , NC 28208 Report Number : 23-270-0016 REPORT OFANAL YSIS Lab No : 96386 Matrix: Aqueous Sample ID: SW-01 Sampled: 9/27/2023 8:30 Analytical Method: 6200E Prep Batch(es): V38694 10/04/23 09:00 Prep Method: 6200 PT Test Results Units MDL MQL DF Date / Time By Analytical Analyzed Batch 1,3-Dichlorobenzene <0.190 Ng/L 0.190 0.500 1 10/04/23 19:03 MSA V38696 1,4-Dichlorobenzene <0.210 N9/L 0.210 0.500 1 10/04/23 19:03 MSA V38696 Dichlorodifluoromethane <1.20 N9/L 1.20 5.00 1 10/04/23 19:03 MSA V38696 1,1-Dichloroethane <0.240 N9/L 0.240 0.500 1 10/04/23 19:03 MSA V38696 1,2-Dichloroethane <0.150 N9/L 0.150 0.500 1 10/04/23 19:03 MSA V38696 1,1-Dichloroethene <0.150 N9/L 0.150 0.500 1 10/04/23 19:03 MSA V38696 cis- 1,2-Dichloroethene <0.200 N9/L 0.200 0.500 1 10/04/23 19:03 MSA V38696 trans-1,2-Dichloroethene <0.180 N9/L 0.180 0.500 1 10/04/23 19:03 MSA V38696 1,2-Dichloropropane <0.190 N9/L 0.190 0.500 1 10/04/23 19:03 MSA V38696 1,3-Dichloropropane <0.130 N9/L 0.130 0.500 1 10/04/23 19:03 MSA V38696 2,2-Dichloropropane <0.210 N9/L 0.210 2.00 1 10/04/23 19:03 MSA V38696 1,1-Dichloropropene <0.200 N9/L 0.200 0.500 1 10/04/23 19:03 MSA V38696 cis- 1,3-Dichloropropene <0.210 N9/L 0.210 0.500 1 10/04/23 19:03 MSA V38696 trans-1,3-Dichloropropene <0.150 N9/L 0.150 0.500 1 10/04/23 19:03 MSA V38696 Ethanol <42.0 N9/L 42.0 200 1 10/04/23 19:03 MSA V38696 Ethylbenzene <0.170 N9/L 0.170 0.500 1 10/04/23 19:03 MSA V38696 Hexachlorobutadiene <0.350 N9/L 0.350 3.00 1 10/04/23 19:03 MSA V38696 2-Hexanone <0.380 N9/L 0.380 1.00 1 10/04/23 19:03 MSA V38696 Isopropyl benzene <0.180 N9/L 0.180 0.500 1 10/04/23 19:03 MSA V38696 4-Isopropyl toluene <0.089 N9/L 0.089 0.500 1 10/04/23 19:03 MSA V38696 Methyl Ethyl Ketone (MEK) <0.710 N9/L 0.710 5.00 1 10/04/23 19:03 MSA V38696 Methyl tert-butyl ether (MTBE) <0.140 N9/L 0.140 1.00 1 10/04/23 19:03 MSA V38696 4-Methyl-2-Pentanone <0.078 N9/L 0.078 1.00 1 10/04/23 19:03 MSA V38696 Qualifiers/ DF Dilution Factor J Estimated value Definitions MQL Method Quantitation Limit Page 7 of 26 a Wayp��• nt . 0 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 ANALYTICAL www.waypointanalytical.com 01223 WSP USA Envi. & Infrastructure Inc. (Charlotte) Project CDIA Rob Foster Report Date : 10/06/2023 2801 Yorkmont Rd. #100 Information : Project #6228-21-0061.09 Received : 09/27/2023 Charlotte , NC 28208 Report Number : 23-270-0016 REPORT OFANAL YSIS Lab No : 96386 Matrix: Aqueous Sample ID: SW-01 Sampled: 9/27/2023 8:30 Analytical Method: 6200E Prep Batch(es): V38694 10/04/23 09:00 Prep Method: 6200 PT Test Results Units MDL MQL DF Date / Time By Analytical Analyzed Batch Methylene Chloride <0.330 Ng/L 0.330 2.00 1 10/04/23 19:03 MSA V38696 Naphthalene <0.470 N9/L 0.470 1.00 1 10/04/23 19:03 MSA V38696 n-Propylbenzene <0.190 N9/L 0.190 0.500 1 10/04/23 19:03 MSA V38696 Styrene <0.220 N9/L 0.220 0.500 1 10/04/23 19:03 MSA V38696 1,1,1,2-Tetrachloroethane <0.160 N9/L 0.160 0.500 1 10/04/23 19:03 MSA V38696 1,1,2,2-Tetrachloroethane <0.160 N9/L 0.160 0.500 1 10/04/23 19:03 MSA V38696 Tetrachloroethene <0.220 N9/L 0.220 0.500 1 10/04/23 19:03 MSA V38696 Toluene <0.220 N9/L 0.220 0.500 1 10/04/23 19:03 MSA V38696 1,2,3-Trichlorobenzene <0.380 N9/L 0.380 0.500 1 10/04/23 19:03 MSA V38696 1,2,4-Trichlorobenzene <0.310 N9/L 0.310 0.500 1 10/04/23 19:03 MSA V38696 1,1,1-Trichloroethane <0.160 N9/L 0.160 0.500 1 10/04/23 19:03 MSA V38696 1,1,2-Trichloroethane <0.096 N9/L 0.096 0.500 1 10/04/23 19:03 MSA V38696 Trichloroethene <0.180 N9/L 0.180 0.500 1 10/04/23 19:03 MSA V38696 Trichlorofluoromethane <0.180 N9/L 0.180 0.500 1 10/04/23 19:03 MSA V38696 1,2,3-Trichloropropane <0.270 N9/L 0.270 0.500 1 10/04/23 19:03 MSA V38696 1,2,4-Trimethyl benzene <0.190 N9/L 0.190 0.500 1 10/04/23 19:03 MSA V38696 1,3,5-Trimethyl benzene <0.180 N9/L 0.180 0.500 1 10/04/23 19:03 MSA V38696 Vinyl Acetate <1.00 N9/L 1.00 5.00 1 10/04/23 19:03 MSA V38696 Vinyl Chloride <0.170 N9/L 0.170 0.500 1 10/04/23 19:03 MSA V38696 o-Xylene <0.210 N9/L 0.210 0.500 1 10/04/23 19:03 MSA V38696 m,p-Xylene <0.420 N9/L 0.420 1.00 1 10/04/23 19:03 MSA V38696 Qualifiers/ DF Dilution Factor J Estimated value Definitions MQL Method Quantitation Limit Page 8 of 26 a Wayp��• nt . 0 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 ANALYTICAL www.waypointanalytical.com 01223 WSP USA Envi. & Infrastructure Inc. (Charlotte) Project CDIA Rob Foster Report Date : 10/06/2023 2801 Yorkmont Rd. #100 Information : Project #6228-21-0061.09 Received : 09/27/2023 Charlotte , NC 28208 Report Number : 23-270-0016 REPORT OFANAL YSIS Lab No : 96386 Matrix: Aqueous Sample ID: SW-01 Sampled: 9/27/2023 8:30 Analytical Method: 6200E Prep Batch(es): V38694 10/04/23 09:00 Prep Method: 6200 PT Test Results Units MDL MQL DF Date / Time By Analytical Analyzed Batch Xylene (Total) <0.21 Ng/L 0.210 0.500 1 10/04/23 19:03 V38696 Surrogate:4-Bromofluorobenzene 106 Limits:70-130% 1 10/04/23 19:03 MSA V38696 Surrogate: Dibromofluoromethane 95.2 Limits: 70-130% 1 10/04/23 19:03 MSA V38696 Surrogate: 1,2-Dichloroethane - d4 84.4 Limits: 70-130% 1 10/04/23 19:03 MSA V38696 Surrogate: Toluene-d8 99.6 Limits: 70-130% 1 10/04/23 19:03 MSA V38696 Analytical Method: 625.1 Prep Batch(es): V38547 10/02/23 10:16 Prep Method: 625.1 (Prep) Test Results Units MDL MOL DF Date / Time By Analytical Analyzed Batch Acenaphthene <0.302 Ng/L 0.302 2.00 1 10/02/23 20:15 AMP V38587 Acenaphthylene <0.297 Ng/L 0.297 2.00 1 10/02/23 20:15 AMP V38587 Anthracene <0.836 Ng/L 0.836 2.00 1 10/02/23 20:15 AMP V38587 Benzidine <1.32 Ng/L 1.32 10.0 1 10/02/23 20:15 AMP V38587 Benzo(a)anthracene 1.823 Ng/L 0.637 2.00 1 10/02/23 20:15 AMP V38587 Benzo(a)pyrene 1.543 Ng/L 1.02 2.00 1 10/02/23 20:15 AMP V38587 Benzo(b)fluoranthene <2.49 Ng/L 2.49 5.00 1 10/02/23 20:15 AMP V38587 Benzo(g,h,i)perylene 2.803 Ng/L 1.01 5.00 1 10/02/23 20:15 AMP V38587 Benzo(k)fluoranthene 2.033 Ng/L 1.99 5.00 1 10/02/23 20:15 AMP V38587 Benzoic Acid <1.10 Ng/L 1.10 10.0 1 10/02/23 20:15 AMP V38587 Benzyl alcohol <0.684 Ng/L 0.684 5.00 1 10/02/23 20:15 AMP V38587 Bis(2-Chloroethoxy)methane <0.468 Ng/L 0.468 5.00 1 10/02/23 20:15 AMP V38587 Bis(2-Chloroethyl)ether <1.04 Ng/L 1.04 5.00 1 10/02/23 20:15 AMP V38587 Qualifiers/ DF Dilution Factor J Estimated value Definitions MQL Method Quantitation Limit Page 9 of 26 a Wayp��• nt . 0 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 ANALYTICAL www.waypointanalytical.com 01223 WSP USA Envi. & Infrastructure Inc. (Charlotte) Project CDIA Rob Foster Report Date : 10/06/2023 2801 Yorkmont Rd. #100 Information : Project #6228-21-0061.09 Received : 09/27/2023 Charlotte , NC 28208 Report Number : 23-270-0016 REPORT OFANAL YSIS Lab No : 96386 Matrix: Aqueous Sample ID: SW-01 Sampled: 9/27/2023 8:30 Analytical Method: 625.1 Prep Batch(es): V38S47 10/02/23 10:16 Prep Method: 625.1 (Prep) Test Results Units MDL MQL DF Date / Time By Analytical Analyzed Batch Bis(2-Chloroisopropyl)ether <1.08 N9/L 1.08 5.00 1 10/02/23 20:15 AMP V38587 Bis(2-ethylhexyl)phthalate <3.46 N9/L 3.46 10.0 1 10/02/23 20:15 AMP V38587 4-Bromophenyl phenyl ether <1.11 N9/L 1.11 5.00 1 10/02/23 20:15 AMP V38587 Butyl benzyl phthalate <1.83 N9/L 1.83 5.00 1 10/02/23 20:15 AMP V38587 4-Chloro-3-methylphenol <1.18 N9/L 1.18 5.00 1 10/02/23 20:15 AMP V38587 2-Chloronaphthalene <7.38 N9/L 7.38 20.0 1 10/02/23 20:15 AMP V38587 2-Chlorophenol <0.938 N9/L 0.938 10.0 1 10/02/23 20:15 AMP V38587 4-Chlorophenyl phenyl ether <1.71 N9/L 1.71 5.00 1 10/02/23 20:15 AMP V38587 Chrysene 2.07 N9/L 0.405 2.00 1 10/02/23 20:15 AMP V38587 Dibenz(a,h)anthracene 2.28 N9/L 0.434 2.00 1 10/02/23 20:15 AMP V38587 Dibenzofuran <0.856 N9/L 0.856 5.00 1 10/02/23 20:15 AMP V38587 1,2-Dichlorobenzene <2.00 N9/L 2.00 5.00 1 10/02/23 20:15 AMP V38587 1,3-Dichlorobenzene <2.00 N9/L 2.00 5.00 1 10/02/23 20:15 AMP V38587 1,4-Dichlorobenzene <2.05 N9/L 2.05 5.00 1 10/02/23 20:15 AMP V38587 3,3'-Dichlorobenzidine <1.89 N9/L 1.89 5.00 1 10/02/23 20:15 AMP V38587 2,4-Dichlorophenol <1.46 N9/L 1.46 10.0 1 10/02/23 20:15 AMP V38587 Diethyl phthalate <0.745 N9/L 0.745 5.00 1 10/02/23 20:15 AMP V38587 Dimethyl phthalate <0.939 N9/L 0.939 5.00 1 10/02/23 20:15 AMP V38587 2,4-Dimethyl phenol <1.57 N9/L 1.57 20.0 1 10/02/23 20:15 AMP V38587 Di-n-butyl phthalate <2.06 N9/L 2.06 5.00 1 10/02/23 20:15 AMP V38587 4,6-Dinitro-2-methylphenol <2.07 N9/L 2.07 10.0 1 10/02/23 20:15 AMP V38587 2,4-Dinitrophenol <1.92 N9/L 1.92 10.0 1 10/02/23 20:15 AMP V38587 2,4-Dinitrotoluene <1.11 N9/L 1.11 5.00 1 10/02/23 20:15 AMP V38587 Qualifiers/ DF Dilution Factor J Estimated value Definitions MQL Method Quantitation Limit Page 10 of 26 a Wayp��• nt . 0 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 ANALYTICAL www.waypointanalytical.com 01223 WSP USA Envi. & Infrastructure Inc. (Charlotte) Project CDIA Rob Foster Report Date : 10/06/2023 2801 Yorkmont Rd. #100 Information : Project #6228-21-0061.09 Received : 09/27/2023 Charlotte , NC 28208 Report Number : 23-270-0016 REPORT OFANAL YSIS Lab No : 96386 Matrix: Aqueous Sample ID: SW-01 Sampled: 9/27/2023 8:30 Analytical Method: 625.1 Prep Batch(es): V38S47 10/02/23 10:16 Prep Method: 625.1 (Prep) Test Results Units MDL MQL DF Date / Time By Analytical Analyzed Batch 2,6-Dinitrotoluene <0.809 Ng/L 0.809 5.00 1 10/02/23 20:15 AMP V38587 Di-n-Octyl Phthalate <1.65 Ng/L 1.65 5.00 1 10/02/23 20:15 AMP V38587 Fluoranthene <0.250 Ng/L 0.250 2.00 1 10/02/23 20:15 AMP V38587 Fluorene <0.807 Ng/L 0.807 2.00 1 10/02/23 20:15 AMP V38587 Hexachlorobenzene <0.979 Ng/L 0.979 5.00 1 10/02/23 20:15 AMP V38587 Hexachlorobutadiene <2.73 Ng/L 2.73 5.00 1 10/02/23 20:15 AMP V38587 Hexachlorocyclopentadiene <2.05 Ng/L 2.05 5.00 1 10/02/23 20:15 AMP V38587 Hexachloroethane <1.76 Ng/L 1.76 5.00 1 10/02/23 20:15 AMP V38587 Indeno(1,2,3-cd)pyrene 2.12 Ng/L 0.477 2.00 1 10/02/23 20:15 AMP V38587 Isophorone <0.444 Ng/L 0.444 5.00 1 10/02/23 20:15 AMP V38587 1-Methylnaphthalene <1.14 Ng/L 1.14 2.00 1 10/02/23 20:15 AMP V38587 2-Methylnaphthalene <0.666 Ng/L 0.666 2.00 1 10/02/23 20:15 AMP V38587 Naphthalene <0.728 Ng/L 0.728 2.00 1 10/02/23 20:15 AMP V38587 Nitrobenzene <0.905 Ng/L 0.905 5.00 1 10/02/23 20:15 AMP V38587 2-Nitrophenol <0.493 Ng/L 0.493 5.00 1 10/02/23 20:15 AMP V38587 4-Nitrophenol <1.23 Ng/L 1.23 10.0 1 10/02/23 20:15 AMP V38587 N-Nitrosodiphenylamine <1.10 Ng/L 1.10 5.00 1 10/02/23 20:15 AMP V38587 N-Nitroso-di-n-propylamine <0.641 Ng/L 0.641 5.00 1 10/02/23 20:15 AMP V38587 Pentachlorophenol <1.43 Ng/L 1.43 5.00 1 10/02/23 20:15 AMP V38587 Phenanthrene <0.428 Ng/L 0.428 2.00 1 10/02/23 20:15 AMP V38587 Phenol <0.651 Ng/L 0.651 5.00 1 10/02/23 20:15 AMP V38587 Pyrene <0.434 Ng/L 0.434 2.00 1 10/02/23 20:15 AMP V38587 1,2,4-Trichlorobenzene <2.21 Ng/L 2.21 5.00 1 10/02/23 20:15 AMP V38587 Qualifiers/ DF Dilution Factor J Estimated value Definitions MQL Method Quantitation Limit Page 11 of 26 a Wayp��• nt . 0 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 ANALYTICAL www.waypointanalytical.com 01223 WSP USA Envi. & Infrastructure Inc. (Charlotte) Project CDIA Rob Foster 2801 Yorkmont Rd. #100 Information : Project #6228-21-0061.09 Charlotte , NC 28208 Report Number : 23-270-0016 REPORT OFANAL YSIS Report Date : 10/06/2023 Received : 09/27/2023 Lab No : 96386 Matrix: Aqueous Sample ID: SW-01 Sampled: 9/27/2023 8:30 Analytical Method: 625.1 Prep Method: 625.1 (Prep) Test Results 2,4,6-Trichlorophenol <1.32 Surrogate: Phenol-d5 Surrogate: 2-Fluorobiphenyl Surrogate: 2-Fluorophenol Surrogate: Nitrobenzene-d5 Surrogate: 4-Terphenyl-d 14 Surrogate: 2,4,6-Tribromophenol Qualifiers/ DF Dilution Factor Definitions MQL Method Quantitation Limit Prep Batch(es): V38S47 10/02/23 10:16 Units MDL MQL DF Date / Time By Analytical Analyzed Batch Ng/L 1.32 5.00 26.9 Limits: 10-63% 78.0 Limits: 49-118% 37.5 Limits: 22-84% 69.2 Limits: 43-123% 81.0 Limits: 49-151% 78.1 Limits: 31-144% 1 10/02/23 20:15 AMP V38587 1 10/02/23 20:15 AMP 625.1 1 10/02/23 20:15 AMP V38587 1 10/02/23 20:15 AMP V38587 1 10/02/23 20:15 AMP V38587 1 10/02/23 20:15 AMP V38587 1 10/02/23 20:15 AMP V38587 J Estimated value Page 12 of 26 Waypointo ANALYTICAL 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 www.waypointanalytical.com Quality Control Data Client ID: WSP USA Env!. & Infrastructure Inc. (Charlotte) Project Description: CDIA Report No: 23-270-0016 QC Prep: V38694 QC Analytical Batch(es): V38696 QC Prep Batch Method: 6200 PT Analysis Method: 6200B Analysis Description: Volatile Organic Compounds - GC/MS Lab Reagent Blank LRB-V38694 Matrix: AQU Associated Lab Samples: 96386 Blank MDL MQL Analyzed a/o % Rec Parameter Units Result Recovery Limits Acetone pg/L <1.80 1.80 10.0 10/04/23 15:07 Benzene pg/L <0.180 0.180 0.500 10/04/23 15:07 Bromobenzene pg/L <0.210 0.210 0.500 10/04/23 15:07 Bromochloromethane pg/L <0.420 0.420 1.00 10/04/23 15:07 Bromodichloromethane pg/L <0.160 0.160 0.500 10/04/23 15:07 Bromoform pg/L <1.50 1.50 5.00 10/04/23 15:07 Bromomethane pg/L <0.280 0.280 1.00 10/04/23 15:07 n-Butylbenzene pg/L <0.180 0.180 0.500 10/04/23 15:07 sec -Butyl benzene pg/L <0.200 0.200 0.500 10/04/23 15:07 tert-Butyl benzene pg/L <0.920 0.920 2.00 10/04/23 15:07 Carbon Tetrachloride pg/L <0.180 0.180 0.500 10/04/23 15:07 Chlorobenzene pg/L <0.190 0.190 0.500 10/04/23 15:07 Chlorodibromomethane pg/L <0.190 0.190 0.500 10/04/23 15:07 Chloroethane pg/L <0.430 0.430 1.00 10/04/23 15:07 Chloroform pg/L <0.220 0.220 0.500 10/04/23 15:07 Chloromethane pg/L <0.220 0.220 0.500 10/04/23 15:07 2-Chlorotoluene pg/L <0.200 0.200 0.500 10/04/23 15:07 4-Chlorotoluene pg/L <0.200 0.200 0.500 10/04/23 15:07 Di -Isopropyl Ether (DIPE) pg/L <0.500 0.500 0.500 10/04/23 15:07 1,2-Dibromo-3-Chloropropane pg/L <1.10 1.10 2.00 10/04/23 15:07 1,2-Dibromoethane pg/L <0.200 0.200 0.500 10/04/23 15:07 Dibromomethane pg/L <0.230 0.230 0.500 10/04/23 15:07 1,2-Dichlorobenzene pg/L <0.220 0.220 0.500 10/04/23 15:07 1,3-Dichlorobenzene pg/L <0.190 0.190 0.500 10/04/23 15:07 1,4-Dichlorobenzene pg/L <0.210 0.210 0.500 10/04/23 15:07 Dichlorodifluoromethane pg/L <1.20 1.20 5.00 10/04/23 15:07 1,1-Dichloroethane pg/L <0.240 0.240 0.500 10/04/23 15:07 Date: 10/06/2023 12:52 PM Page 1 of 12 Page 13 of 26 Waypointo ANALYTICAL 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 www.waypointanalytical.com Quality Control Data Client ID: WSP USA Env!. & Infrastructure Inc. (Charlotte) Project Description: CDIA Report No: 23-270-0016 QC Prep: V38694 QC Analytical Batch(es): V38696 QC Prep Batch Method: 6200 PT Analysis Method: 6200B Analysis Description: Volatile Organic Compounds - GC/MS Lab Reagent Blank LRB-V38694 Matrix: AQU Associated Lab Samples: 96386 Blank MDL MQL Analyzed a/o % Rec Parameter Units Result Recovery Limits 1,2-Dichloroethane pg/L <0.150 0.150 0.500 10/04/23 15:07 1,1-Dichloroethene pg/L <0.150 0.150 0.500 10/04/23 15:07 cis-1,2-Dichloroethene pg/L <0.200 0.200 0.500 10/04/23 15:07 trans-1,2-Dichloroethene pg/L <0.180 0.180 0.500 10/04/23 15:07 1,2-Dichloropropane pg/L <0.190 0.190 0.500 10/04/23 15:07 1,3-Dichloropropane pg/L <0.130 0.130 0.500 10/04/23 15:07 2,2-Dichloropropane pg/L <0.210 0.210 2.00 10/04/23 15:07 1,1-Dichloropropene pg/L <0.200 0.200 0.500 10/04/23 15:07 cis-1,3-Dichloropropene pg/L <0.210 0.210 0.500 10/04/23 15:07 trans-1,3-Dichloropropene pg/L <0.150 0.150 0.500 10/04/23 15:07 Ethanol pg/L <42.0 42.0 200 10/04/23 15:07 Ethylbenzene pg/L <0.170 0.170 0.500 10/04/23 15:07 Hexachlorobutadiene pg/L <0.350 0.350 3.00 10/04/23 15:07 2-Hexanone pg/L <0.380 0.380 1.00 10/04/23 15:07 Isopropyl benzene pg/L <0.180 0.180 0.500 10/04/23 15:07 4-Isopropyl toluene pg/L <0.089 0.089 0.500 10/04/23 15:07 Methyl Ethyl Ketone (MEK) pg/L <0.710 0.710 5.00 10/04/23 15:07 Methyl tert-butyl ether (MTBE) pg/L <0.140 0.140 1.00 10/04/23 15:07 4-Methyl-2-Pentanone pg/L <0.078 0.078 1.00 10/04/23 15:07 Methylene Chloride pg/L <0.330 0.330 2.00 10/04/23 15:07 Naphthalene pg/L <0.470 0.470 1.00 10/04/23 15:07 n-Propylbenzene pg/L <0.190 0.190 0.500 10/04/23 15:07 Styrene pg/L <0.220 0.220 0.500 10/04/23 15:07 1,1,1,2-Tetrachloroethane pg/L <0.160 0.160 0.500 10/04/23 15:07 1,1,2,2-Tetrachloroethane pg/L <0.160 0.160 0.500 10/04/23 15:07 Tetrachloroethene pg/L <0.220 0.220 0.500 10/04/23 15:07 Toluene pg/L <0.220 0.220 0.500 10/04/23 15:07 Date: 10/06/2023 12:52 PM Page 2 of 12 Page 14 of 26 Waypointo ANALYTICAL 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 www.waypointanalytical.com Quality Control Data Client ID: WSP USA Env!. & Infrastructure Inc. (Charlotte) Project Description: CDIA Report No: 23-270-0016 QC Prep: V38694 QC Analytical Batch(es): V38696 QC Prep Batch Method: 6200 PT Analysis Method: 6200B Analysis Description: Volatile Organic Compounds - GC/MS Lab Reagent Blank LRB-V38694 Matrix: AQU Associated Lab Samples: 96386 Blank MDL MQL Analyzed a/o % Rec Parameter Units Result Recovery Limits 1,2,3-Trichlorobenzene pg/L <0.380 0.380 0.500 10/04/23 15:07 1,2,4-Trichlorobenzene pg/L <0.310 0.310 0.500 10/04/23 15:07 1,1,1-Trichloroethane pg/L <0.160 0.160 0.500 10/04/23 15:07 1,1,2-Trichloroethane pg/L <0.096 0.096 0.500 10/04/23 15:07 Trichloroethene pg/L <0.180 0.180 0.500 10/04/23 15:07 Trichlorofluoromethane pg/L <0.180 0.180 0.500 10/04/23 15:07 1,2,3-Trichloropropane pg/L <0.270 0.270 0.500 10/04/23 15:07 1,2,4-Trimethyl benzene pg/L <0.190 0.190 0.500 10/04/23 15:07 1,3,5-Trimethyl benzene pg/L <0.180 0.180 0.500 10/04/23 15:07 Vinyl Acetate pg/L <1.00 1.00 5.00 10/04/23 15:07 Vinyl Chloride pg/L <0.170 0.170 0.500 10/04/23 15:07 o-Xylene pg/L <0.210 0.210 0.500 10/04/23 15:07 m,p-Xylene pg/L <0.420 0.420 1.00 10/04/23 15:07 4-Bromofluorobenzene (S) 10/04/23 15:07 104 70-130 Dibromofluoromethane (S) 10/04/23 15:07 96.4 70-130 1,2-Dichloroethane - d4 (S) 10/04/23 15:07 88.4 70-130 Toluene-d8 (S) 10/04/23 15:07 99.8 70-130 Laboratory Control Sample & LCSD LCS-V38694 LCSD-V38694 Spike LCS LCSD LCS LCSD a/o Rec Parameter Units Conc. Result Result %Rec % Rec Limits RPD Max RPD Acetone pg/L 40.0 60.5 58.3 151 146 40-160 3.7 20.0 Benzene pg/L 20.0 20.9 20.7 105 104 70-130 0.9 20.0 Bromobenzene pg/L 20.0 21.5 21.6 108 108 70-130 0.4 20.0 Bromochloromethane pg/L 20.0 20.3 20.4 102 102 70-130 0.4 20.0 Bromodichloromethane pg/L 20.0 20.5 20.6 103 103 70-130 0.4 20.0 Date: 10/06/2023 12:52 PM Page 3 of 12 Page 15 of 26 Waypointo ANALYTICAL 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 www.waypointanalytical.com Quality Control Data Client ID: WSP USA Env!. & Infrastructure Inc. (Charlotte) Project Description: CDIA Report No: 23-270-0016 QC Prep: V38694 QC Analytical Batch(es): V38696 QC Prep Batch Method: 6200 PT Analysis Method: 6200B Analysis Description: Volatile Organic Compounds - GC/MS Laboratory Control Sample & LCSD LCS-V38694 LCSD-V38694 Spike LCS LCSD LCS LCSD % Rec Parameter Units Conc. Result Result %Rec % Rec Limits RPD Max RPD Bromoform pg/L 20.0 17.9 17.9 89.5 89.5 70-130 0.0 20.0 Bromomethane pg/L 20.0 27.7 26.4 139 132 60-140 4.8 20.0 n-Butylbenzene pg/L 20.0 22.3 21.6 112 108 70-130 3.1 20.0 sec -Butyl benzene pg/L 20.0 21.5 21.4 108 107 70-130 0.4 20.0 tert-Butyl benzene pg/L 20.0 22.2 22.2 111 111 70-130 0.0 20.0 Carbon Tetrachloride pg/L 20.0 19.7 19.8 98.5 99.0 70-130 0.5 20.0 Chlorobenzene pg/L 20.0 21.2 21.3 106 107 70-130 0.4 20.0 Chlorodibromomethane pg/L 20.0 20.5 20.8 103 104 70-130 1.4 20.0 Chloroethane pg/L 20.0 19.1 18.4 95.5 92.0 60-140 3.7 20.0 Chloroform pg/L 20.0 20.1 20.0 101 100 70-130 0.4 20.0 Chloromethane pg/L 20.0 22.5 22.2 113 111 60-140 1.3 20.0 2-Chlorotoluene pg/L 20.0 21.8 21.6 109 108 70-130 0.9 20.0 4-Chlorotoluene pg/L 20.0 22.0 21.8 110 109 70-130 0.9 20.0 Di -Isopropyl Ether (DIPE) pg/L 20.0 20.4 20.5 102 103 70-130 0.4 20.0 1,2-Dibromo-3-Chloropropane pg/L 20.0 18.6 17.9 93.0 89.5 70-130 3.8 20.0 1,2-Dibromoethane pg/L 20.0 21.5 21.2 108 106 70-130 1.4 20.0 Dibromomethane pg/L 20.0 19.3 19.4 96.5 97.0 70-130 0.5 20.0 1,2-Dichlorobenzene pg/L 20.0 21.8 21.5 109 108 70-130 1.3 20.0 1,3-Dichlorobenzene pg/L 20.0 21.6 21.8 108 109 70-130 0.9 20.0 1,4-Dichlorobenzene pg/L 20.0 21.0 20.6 105 103 70-130 1.9 20.0 Dichlorodifluoromethane pg/L 20.0 18.9 18.7 94.5 93.5 60-140 1.0 20.0 1,1-Dichloroethane pg/L 20.0 21.4 21.0 107 105 70-130 1.8 20.0 1,2-Dichloroethane pg/L 20.0 19.3 18.6 96.5 93.0 70-130 3.6 20.0 1,1-Dichloroethene pg/L 20.0 20.7 21.8 104 109 70-130 5.1 20.0 cis-1,2-Dichloroethene pg/L 20.0 20.4 20.6 102 103 70-130 0.9 20.0 trans-1,2-Dichloroethene pg/L 20.0 21.1 21.1 106 106 70-130 0.0 20.0 Date: 10/06/2023 12:52 PM Page 4 of 12 Page 16 of 26 Waypointo ANALYTICAL 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 www.waypointanalytical.com Quality Control Data Client ID: WSP USA Env!. & Infrastructure Inc. (Charlotte) Project Description: CDIA Report No: 23-270-0016 QC Prep: V38694 QC Analytical Batch(es): V38696 QC Prep Batch Method: 6200 PT Analysis Method: 6200B Analysis Description: Volatile Organic Compounds - GC/MS Laboratory Control Sample & LCSD LCS-V38694 LCSD-V38694 Spike LCS LCSD LCS LCSD % Rec Parameter Units Conc. Result Result %Rec % Rec Limits RPD Max RPD 1,2-Dichloropropane pg/L 20.0 21.6 21.1 108 106 70-130 2.3 20.0 1,3-Dichloropropane pg/L 20.0 20.8 20.6 104 103 70-130 0.9 20.0 2,2-Dichloropropane pg/L 20.0 21.8 21.3 109 107 70-130 2.3 20.0 1,1-Dichloropropene pg/L 20.0 22.1 22.1 111 111 70-130 0.0 20.0 cis-1,3-Dichloropropene pg/L 20.0 20.7 20.7 104 104 70-130 0.0 20.0 trans-1,3-Dichloropropene pg/L 20.0 20.0 20.4 100 102 70-130 1.9 20.0 Ethanol pg/L 500 401 411 80.2 82.2 60-140 2.4 20.0 Ethylbenzene pg/L 20.0 20.5 20.5 103 103 70-130 0.0 20.0 Hexachlorobutadiene pg/L 20.0 22.8 22.3 114 112 70-130 2.2 20.0 2-Hexanone pg/L 20.0 21.9 23.5 110 118 60-140 7.0 20.0 Isopropyl benzene pg/L 20.0 22.5 22.6 113 113 70-130 0.4 20.0 4-Isopropyl toluene pg/L 20.0 22.5 22.2 113 111 70-130 1.3 20.0 Methyl Ethyl Ketone (MEK) pg/L 20.0 22.2 23.5 111 118 60-140 5.6 20.0 Methyl tert-butyl ether (MTBE) pg/L 20.0 20.6 20.1 103 101 70-130 2.4 20.0 4-Methyl-2-Pentanone pg/L 20.0 19.2 19.1 96.0 95.5 60-140 0.5 20.0 Methylene Chloride pg/L 20.0 20.4 20.6 102 103 70-130 0.9 20.0 Naphthalene pg/L 20.0 19.9 19.3 99.5 96.5 70-130 3.0 20.0 n-Propylbenzene pg/L 20.0 21.4 21.2 107 106 70-130 0.9 20.0 Styrene pg/L 20.0 21.0 21.1 105 106 70-130 0.4 20.0 1,1,1,2-Tetrachloroethane pg/L 20.0 21.6 21.7 108 109 70-130 0.4 20.0 1,1,2,2-Tetrachloroethane pg/L 20.0 21.2 20.9 106 105 70-130 1.4 20.0 Tetrachloroethene pg/L 20.0 22.5 22.3 113 112 70-130 0.8 20.0 Toluene pg/L 20.0 20.3 20.5 102 103 70-130 0.9 20.0 1,2,3-Trichlorobenzene pg/L 20.0 24.2 22.4 121 112 70-130 7.7 20.0 1,2,4-Trichlorobenzene pg/L 20.0 21.2 20.1 106 101 70-130 5.3 20.0 1,1,1-Trichloroethane pg/L 20.0 20.8 20.4 104 102 70-130 1.9 20.0 Date: 10/06/2023 12:52 PM Page 5 of 12 Page 17 of 26 Waypointo ANALYTICAL 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 www.waypointanalytical.com Quality Control Data Client ID: WSP USA Env!. & Infrastructure Inc. (Charlotte) Project Description: CDIA Report No: 23-270-0016 QC Prep: V38694 QC Analytical Batch(es): V38696 QC Prep Batch Method: 6200 PT Analysis Method: 6200B Analysis Description: Volatile Organic Compounds - GC/MS Laboratory Control Sample & LCSD LCS-V38694 LCSD-V38694 Spike LCS LCSD LCS LCSD % Rec Parameter Units Conc. Result Result %Rec % Rec Limits RPD Max RPD 1,1,2-Trichloroethane pg/L 20.0 22.3 21.2 112 106 70-130 5.0 20.0 Trichloroethene pg/L 20.0 21.3 21.0 107 105 70-130 1.4 20.0 Trichlorofluoromethane pg/L 20.0 20.3 20.0 102 100 60-140 1.4 20.0 1,2,3-Trichloropropane pg/L 20.0 20.7 19.2 104 96.0 70-130 7.5 20.0 1,2,4-Trimethyl benzene pg/L 20.0 22.3 22.1 112 111 70-130 0.9 20.0 1,3,5-Trimethyl benzene pg/L 20.0 22.5 22.6 113 113 70-130 0.4 20.0 Vinyl Acetate pg/L 20.0 21.2 22.5 106 113 60-140 5.9 20.0 Vinyl Chloride pg/L 20.0 21.6 21.6 108 108 60-140 0.0 20.0 o-Xylene pg/L 20.0 21.0 21.3 105 107 70-130 1.4 20.0 m,p-Xylene pg/L 40.0 43.1 42.7 108 107 70-130 0.9 20.0 4-Bromofluorobenzene (S) 100 100 70-130 Dibromofluoromethane (S) 95.0 94.2 70-130 1,2-Dichloroethane - d4 (S) 91.8 91.2 70-130 Toluene-d8(S) 100 100 70-130 Date: 10/06/2023 12:52 PM Page 6 of 12 Page 18 of 26 Waypointo ANALYTICAL 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 www.waypointanalytical.com Quality Control Data Client ID: WSP USA Env!. & Infrastructure Inc. (Charlotte) Project Description: CDIA Report No: 23-270-0016 QC Prep: V38547 QC Analytical Batch(es): V38587 QC Prep Batch Method: 625.1 (Prep) Analysis Method: 625.1 Analysis Description: 625.1 - Base/Neutrals and Acids by GC/MS Lab Reagent Blank LRB-V38547 Matrix: AQU Associated Lab Samples: 96386 Blank MDL MQL Analyzed a/o % Rec Parameter Units Result Recovery Limits Acenaphthene pg/L <0.302 0.302 2.00 10/02/23 16:52 Acenaphthylene pg/L <0.297 0.297 2.00 10/02/23 16:52 Anthracene pg/L <0.836 0.836 2.00 10/02/23 16:52 Benzidine pg/L <1.32 1.32 10.0 10/02/23 16:52 Benzo(a)anthracene pg/L <0.637 0.637 2.00 10/02/23 16:52 Benzo(a)pyrene pg/L <1.02 1.02 2.00 10/02/23 16:52 Benzo(b)fluoranthene pg/L <2.49 2.49 5.00 10/02/23 16:52 Benzo(g,h,i)perylene pg/L <1.01 1.01 5.00 10/02/23 16:52 Benzo(k)fluoranthene pg/L <1.99 1.99 5.00 10/02/23 16:52 Benzoic Acid pg/L <1.10 1.10 10.0 10/02/23 16:52 Benzyl alcohol pg/L <0.684 0.684 5.00 10/02/23 16:52 Bis(2-Chloroethoxy)methane pg/L <0.468 0.468 5.00 10/02/23 16:52 Bis(2-Chloroethyl)ether pg/L <1.04 1.04 5.00 10/02/23 16:52 Bis(2-Chloroisopropyl)ether pg/L <1.08 1.08 5.00 10/02/23 16:52 Bis(2-ethylhexyl)phthalate pg/L <3.46 3.46 10.0 10/02/23 16:52 4-Bromophenyl phenyl ether pg/L <1.11 1.11 5.00 10/02/23 16:52 Butyl benzyl phthalate pg/L <1.83 1.83 5.00 10/02/23 16:52 4-Chloro-3-methyl phenol pg/L <1.18 1.18 5.00 10/02/23 16:52 2-Chloronaphthalene pg/L <7.38 7.38 20.0 10/02/23 16:52 2-Chlorophenol pg/L <0.938 0.938 10.0 10/02/23 16:52 4-Chlorophenyl phenyl ether pg/L <1.71 1.71 5.00 10/02/23 16:52 Chrysene pg/L <0.405 0.405 2.00 10/02/23 16:52 Dibenz(a,h)anthracene pg/L <0.434 0.434 2.00 10/02/23 16:52 Dibenzofuran pg/L <0.856 0.856 5.00 10/02/23 16:52 1,2-Dichlorobenzene pg/L <2.00 2.00 5.00 10/02/23 16:52 1,3-Dichlorobenzene pg/L <2.00 2.00 5.00 10/02/23 16:52 1,4-Dichlorobenzene pg/L <2.05 2.05 5.00 10/02/23 16:52 Date: 10/06/2023 12:52 PM Page 7 of 12 Page 19 of 26 Waypointo ANALYTICAL 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 www.waypointanalytical.com Quality Control Data Client ID: WSP USA Env!. & Infrastructure Inc. (Charlotte) Project Description: CDIA Report No: 23-270-0016 QC Prep: V38547 QC Analytical Batch(es): V38587 QC Prep Batch Method: 625.1 (Prep) Analysis Method: 625.1 Analysis Description: 625.1 - Base/Neutrals and Acids by GC/MS Lab Reagent Blank LRB-V38547 Matrix: AQU Associated Lab Samples: 96386 Blank MDL MQL Analyzed a/o % Rec Parameter Units Result Recovery Limits 3,3'-Dichlorobenzidine pg/L <1.89 1.89 5.00 10/02/23 16:52 2,4-Dichlorophenol pg/L <1.46 1.46 10.0 10/02/23 16:52 Diethyl phthalate pg/L <0.745 0.745 5.00 10/02/23 16:52 Dimethyl phthalate pg/L <0.939 0.939 5.00 10/02/23 16:52 2,4-Dimethylphenol pg/L <1.57 1.57 20.0 10/02/23 16:52 Di-n-butyl phthalate pg/L <2.06 2.06 5.00 10/02/23 16:52 4,6- Din itro-2-methylphenol pg/L <2.07 2.07 10.0 10/02/23 16:52 2,4-Dinitrophenol pg/L <1.92 1.92 10.0 10/02/23 16:52 2,4-Dinitrotoluene pg/L <1.11 1.11 5.00 10/02/23 16:52 2,6-Dinitrotoluene pg/L <0.809 0.809 5.00 10/02/23 16:52 Di-n-Octyl Phthalate pg/L <1.65 1.65 5.00 10/02/23 16:52 Fluoranthene pg/L <0.250 0.250 2.00 10/02/23 16:52 Fluorene pg/L <0.807 0.807 2.00 10/02/23 16:52 Hexachlorobenzene pg/L <0.979 0.979 5.00 10/02/23 16:52 Hexachlorobutadiene pg/L <2.73 2.73 5.00 10/02/23 16:52 Hexachlorocyclopentadiene pg/L <2.05 2.05 5.00 10/02/23 16:52 Hexachloroethane pg/L <1.76 1.76 5.00 10/02/23 16:52 Indeno(1,2,3-cd)pyrene pg/L <0.477 0.477 2.00 10/02/23 16:52 Isophorone pg/L <0.444 0.444 5.00 10/02/23 16:52 1-Methylnaphthalene pg/L <1.14 1.14 2.00 10/02/23 16:52 2-Methylnaphthalene pg/L <0.666 0.666 2.00 10/02/23 16:52 Naphthalene pg/L <0.728 0.728 2.00 10/02/23 16:52 Nitrobenzene pg/L <0.905 0.905 5.00 10/02/23 16:52 2-Nitrophenol pg/L <0.493 0.493 5.00 10/02/23 16:52 4-Nitrophenol pg/L <1.23 1.23 10.0 10/02/23 16:52 N-Nitrosodiphenylamine pg/L <1.10 1.10 5.00 10/02/23 16:52 N-Nitroso-di-n-propylamine pg/L <0.641 0.641 5.00 10/02/23 16:52 Date: 10/06/2023 12:52 PM Page 8 of 12 Page 20 of 26 Waypointo ANALYTICAL 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 www.waypointanalytical.com Quality Control Data Client ID: WSP USA Env!. & Infrastructure Inc. (Charlotte) Project Description: CDIA Report No: 23-270-0016 QC Prep: V38547 QC Analytical Batch(es): V38587 QC Prep Batch Method: 625.1 (Prep) Analysis Method: 625.1 Analysis Description: 625.1 - Base/Neutrals and Acids by GC/MS Lab Reagent Blank LRB-V38547 Matrix: AQU Associated Lab Samples: 96386 Blank MDL MQL Analyzed a/o % Rec Parameter Units Result Recovery Limits Pentachlorophenol pg/L <1.43 1.43 5.00 10/02/23 16:52 Phenanthrene pg/L <0.428 0.428 2.00 10/02/23 16:52 Phenol pg/L <0.651 0.651 5.00 10/02/23 16:52 Pyrene pg/L <0.434 0.434 2.00 10/02/23 16:52 1,2,4-Trichlorobenzene pg/L <2.21 2.21 5.00 10/02/23 16:52 2,4,6-Trichlorophenol pg/L <1.32 1.32 5.00 10/02/23 16:52 2-Fluorobiphenyl(S) 10/02/23 16:52 84.4 49-118 2-Fluorophenol(S) 10/02/23 16:52 49.0 22-84 Nitrobenzene-d5 (S) 10/02/23 16:52 76.6 43-123 4-Terphenyl-d14 (S) 10/02/23 16:52 88.8 49-151 2,4,6-Tribromophenol(S) 10/02/23 16:52 94.8 31-144 Phenol-d5 (S) 10/02/23 16:52 31.7 10-63 Laboratory Control Sample & LCSD Parameter Units LCS-V38547 Spike Conc. LCSD-V38547 LCS Result LCSD Result LCS %Rec LCSD % Rec a/o Rec Limits RPD Max RPD Acenaphthene pg/L 50.0 39.0 40.6 78.0 81.2 47-145 4.0 20.0 Acenaphthylene pg/L 50.0 39.0 40.5 78.0 81.0 33-145 3.7 20.0 Anthracene pg/L 50.0 42.7 43.7 85.4 87.4 27-133 2.3 20.0 Benzidine pg/L 50.0 12.2 16.7 24.4 33.4 15-150 31.1* 20.0 Benzo(a)anthracene pg/L 50.0 41.4 42.9 82.8 85.8 33-143 3.5 20.0 Benzo(a)pyrene pg/L 50.0 46.7 48.0 93.4 96.0 17-163 2.7 20.0 Benzo(b)fluoranthene pg/L 50.0 43.4 44.2 86.8 88.4 24-159 1.8 20.0 Benzo(g,h,i)perylene pg/L 50.0 43.2 44.5 86.4 89.0 10-219 2.9 20.0 Benzo(k)fluoranthene pg/L 50.0 43.7 45.0 87.4 90.0 11-162 2.9 20.0 Benzoic Acid pg/L 50.0 16.8 15.5 33.6 31.0 10-125 8.0 20.0 * QC Fail Date: 10/06/2023 12:52 PM Page 9 of 12 Page 21 of 26 Waypointo ANALYTICAL 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 www.waypointanalytical.com Quality Control Data Client ID: WSP USA Env!. & Infrastructure Inc. (Charlotte) Project Description: CDIA Report No: 23-270-0016 QC Prep: V38547 QC Analytical Batch(es): V38587 QC Prep Batch Method: 625.1 (Prep) Analysis Method: 625.1 Analysis Description: 625.1 - Base/Neutrals and Acids by GC/MS Laboratory Control Sample & LCSD LCS-V38547 LCSD-V38547 Spike LCS LCSD LCS LCSD % Rec Parameter Units Conc. Result Result %Rec % Rec Limits RPD Max RPD Benzyl alcohol pg/L 50.0 38.2 38.2 76.4 76.4 16-107 0.0 20.0 Bis(2-Chloroethoxy)methane pg/L 50.0 33.4 34.3 66.8 68.6 33-184 2.6 20.0 Bis(2-Chloroethyl)ether pg/L 50.0 32.0 32.4 64.0 64.8 12-158 1.2 20.0 Bis(2-Chloroisopropyl)ether pg/L 50.0 32.7 33.4 65.4 66.8 36-166 2.1 20.0 Bis(2-ethylhexyl)phthalate pg/L 50.0 46.9 49.0 93.8 98.0 10-158 4.3 20.0 4-Bromophenyl phenyl ether pg/L 50.0 39.1 40.7 78.2 81.4 53-127 4.0 20.0 Butyl benzyl phthalate pg/L 50.0 44.3 46.7 88.6 93.4 10-152 5.2 20.0 4-Chloro-3-methyl phenol pg/L 50.0 36.2 36.9 72.4 73.8 22-147 1.9 20.0 2-Chloronaphthalene pg/L 50.0 38.6 39.8 77.2 79.6 60-118 3.0 20.0 2-Chlorophenol pg/L 50.0 34.0 34.7 68.0 69.4 23-134 2.0 20.0 4-Chlorophenyl phenyl ether pg/L 50.0 39.2 40.8 78.4 81.6 25-158 4.0 20.0 Chrysene pg/L 50.0 42.6 44.7 85.2 89.4 17-168 4.8 20.0 Dibenz(a,h)anthracene pg/L 50.0 29.4 39.4 58.8 78.8 10-227 29.0* 20.0 Dibenzofuran pg/L 50.0 40.5 42.2 81.0 84.4 39-114 4.1 20.0 1,2-Dichlorobenzene pg/L 50.0 29.7 29.9 59.4 59.8 32-129 0.6 20.0 1,3-Dichlorobenzene pg/L 50.0 28.7 29.2 57.4 58.4 20-124 1.7 20.0 1,4-Dichlorobenzene pg/L 50.0 26.9 27.9 53.8 55.8 20-124 3.6 20.0 3,3'-Dichlorobenzidine pg/L 50.0 36.2 38.4 72.4 76.8 10-262 5.8 20.0 2,4-Dichlorophenol pg/L 50.0 35.2 35.9 70.4 71.8 39-135 1.9 20.0 Diethyl phthalate pg/L 50.0 43.1 44.9 86.2 89.8 10-114 4.0 20.0 Dimethyl phthalate pg/L 50.0 43.2 45.0 86.4 90.0 10-112 4.0 20.0 2,4-Dimethyl phenol pg/L 50.0 45.2 45.7 90.4 91.4 32-119 1.1 20.0 Di-n-butyl phthalate pg/L 50.0 46.1 47.9 92.2 95.8 10-118 3.8 20.0 4,6- Din itro-2-methylphenol pg/L 50.0 42.6 46.0 85.2 92.0 10-181 7.6 20.0 2,4-Dinitrophenol pg/L 50.0 38.5 40.4 77.0 80.8 10-191 4.8 20.0 2,4-Dinitrotoluene pg/L 50.0 45.1 47.7 90.2 95.4 39-139 5.6 20.0 * QC Fail Date: 10/06/2023 12:52 PM Page 10 of 12 Page 22 of 26 Waypointo ANALYTICAL 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 www.waypointanalytical.com Quality Control Data Client ID: WSP USA Env!. & Infrastructure Inc. (Charlotte) Project Description: CDIA Report No: 23-270-0016 QC Prep: V38547 QC Analytical Batch(es): V38587 QC Prep Batch Method: 625.1 (Prep) Analysis Method: 625.1 Analysis Description: 625.1 - Base/Neutrals and Acids by GC/MS Laboratory Control Sample & LCSD LCS-V38547 LCSD-V38547 Spike LCS LCSD LCS LCSD % Rec Parameter Units Conc. Result Result %Rec % Rec Limits RPD Max RPD 2,6-Dinitrotoluene pg/L 50.0 43.9 45.5 87.8 91.0 50-158 3.5 20.0 Di-n-Octyl Phthalate pg/L 50.0 45.9 47.0 91.8 94.0 10-146 2.3 20.0 Fluoranthene pg/L 50.0 42.8 44.3 85.6 88.6 26-137 3.4 20.0 Fluorene pg/L 50.0 41.6 42.9 83.2 85.8 59-121 3.0 20.0 Hexachlorobenzene pg/L 50.0 42.7 44.7 85.4 89.4 10-152 4.5 20.0 Hexachlorobutadiene pg/L 50.0 29.9 30.0 59.8 60.0 24-116 0.3 20.0 Hexachlorocyclopentadiene pg/L 50.0 28.3 29.0 56.6 58.0 32-117 2.4 20.0 Hexachloroethane pg/L 50.0 27.1 28.0 54.2 56.0 40-113 3.2 20.0 Indeno(1,2,3-cd)pyrene pg/L 50.0 43.3 44.7 86.6 89.4 10-171 3.1 20.0 Isophorone pg/L 50.0 32.2 32.8 64.4 65.6 21-196 1.8 20.0 1-Methylnaphthalene pg/L 50.0 31.7 31.9 63.4 63.8 40-135 0.6 20.0 2-Methylnaphthalene pg/L 50.0 32.3 32.7 64.6 65.4 18-121 1.2 20.0 Naphthalene pg/L 50.0 29.8 29.5 59.6 59.0 21-133 1.0 20.0 Nitrobenzene pg/L 50.0 31.7 32.1 63.4 64.2 35-180 1.2 20.0 2-Nitrophenol pg/L 50.0 32.4 32.4 64.8 64.8 29-182 0.0 20.0 4-Nitrophenol pg/L 50.0 22.7 23.5 45.4 47.0 10-132 3.4 20.0 N-Nitrosodiphenylamine pg/L 50.0 48.5 49.7 97.0 99.4 69-152 2.4 20.0 N-Nitroso-di-n-propylamine pg/L 50.0 38.4 39.8 76.8 79.6 10-230 3.5 20.0 Pentachlorophenol pg/L 50.0 49.4 52.9 98.8 106 14-176 6.8 20.0 Phenanthrene pg/L 50.0 42.9 44.3 85.8 88.6 54-120 3.2 20.0 Phenol pg/L 50.0 17.5 17.1 35.0 34.2 10-112 2.3 20.0 Pyrene pg/L 50.0 43.6 44.7 87.2 89.4 52-115 2.4 20.0 1,2,4-Trichlorobenzene pg/L 50.0 29.0 28.9 58.0 57.8 44-142 0.3 20.0 2,4,6-Trichlorophenol pg/L 50.0 39.6 41.4 79.2 82.8 37-144 4.4 20.0 2-Fluorobiphenyl (S) 76.2 76.8 49-118 2-Fluorophenol(S) 45.1 44.0 22-84 Date: 10/06/2023 12:52 PM Page 11 of 12 Page 23 of 26 Waypointo ANALYTICAL 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 www.waypointanalytical.com Quality Control Data Client ID: WSP USA Env!. & Infrastructure Inc. (Charlotte) Project Description: CDIA Report No: 23-270-0016 QC Prep: V38547 QC Analytical Batch(es): V38587 QC Prep Batch Method: 625.1 (Prep) Analysis Method: 625.1 Analysis Description: 625.1 - Base/Neutrals and Acids by GC/MS Laboratory Control Sample & LCSD LCS-V38547 LCSD-V38547 Spike LCS LCSD LCS LCSD % Rec Parameter Units Conc. Result Result %Rec % Rec Limits RPD Nitrobenzene-d5 (S) 61.6 60.8 43-123 4-Terphenyl-d14 (S) 82.4 84.8 49-151 2,4,6-Tribromophenol (S) 87.4 87.6 31-144 Phenol-d5 (S) 30.0 29.1 10-63 Date: 10/06/2023 12:52 PM Page 12 of 12 Page 24 of 26 WayPAo 1nt. NALYTICAL 449 Springbrook Rd, Charlotte, NC 28217 Main 704.529.6364 www.waypointanalytical.com Shipment Receipt Form Customer Number: 01223 Customer Name: WSP USA Envi. & Infrastructure Inc. (Charlotte) Report Number: 23-270-0016 Shipping Method 0 Fed Ex 0 US Postal 0 Lab 0 Other: 0 UPS 0 Client 0 Courier Thermometer ID: IRT15 5.00 Shipping container/cooler uncompromised? 0 Yes 0 No Number of coolers/boxes received Custody seals intact on shipping container/cooler? 0 Yes 0 No 0 Not Present Custody seals intact on sample bottles? 0 Yes 0 No 0 Not Present Chain of Custody (COC) present? 0 Yes 0 No COC agrees with sample label(s)? 0 Yes 0 No COC properly completed 0 Yes 0 No Samples in proper containers? 0 Yes 0 No Sample containers intact? 0 Yes 0 No Sufficient sample volume for indicated test(s)? 0 Yes 0 No All samples received within holding time? 0 Yes 0 No Cooler temperature in compliance? 0 Yes 0 No Cooler/Samples arrived at the laboratory on ice. Samples were considered acceptable as cooling process had begun. 0 Yes 0 No Water - Sample containers properly preserved 0 Yes 0 No 0 N/A Water - VOA vials free of headspace Co., Yes 0 No 0 N/A Trip Blanks received with VOAs 0 Yes 0 No 0 N/A Soil VOA method 5035 — compliance criteria met 0 Yes 0 No # N/A F_ High concentration container (48 hr) F_ High concentration pre -weighed (methanol -14 d) F_ Low concentration EnCore samplers (48 hr) F_ Low conc pre -weighed vials (Sod Bis -14 d) Special precautions or instructions included? Comments: 0 Yes * No Signature: Angelo Norvell Date & Time: 09/27/2023 13:57:16 Page 25 of 26 L m m a L =r 3 m (A(Amm� Q w n a ::!? aY o 3 7 O q W ,n Lim z w q 4 m x D CL uv K II' llm Lv v 3O F. m iZS C fVl w MM ❑ Cpp�w� m 0 Sf N } F MA 3 v r F- M N O z a �m N mm N +� r N `m m S v a a a a c ` Q x :r n 0 m � m O Z n w m z 0 Q P a a`0 M �_ d A � � �CO 4 N y .n. z y mV ] a M `a Z s 0 mn 0 m C 1' y yA A ❑ 0M A vW z X 0 v m A❑ C m m O N rm- X 1 i Q m Nz n C G w y ° $ C y l� -A 5 3 y y m a a Page 26 of 26