Loading...
HomeMy WebLinkAboutWQ0044177_Engineering Certification_20240311Initial Review Reviewer nathaniel.thornburg Is this submittal an application? (Excluding additional information.) * Yes No If not an application what is the submittal type?* Annual Report Residual Annual Report Additional Information Other Engineering Certification Permit Number (IR) * W00044177 Applicant/Permittee Whispering Pines Farm LLC Email Notifications Does this need review by the hydrogeologist? * Yes No Regional Office CO Reviewer Admin Reviewer Submittal Form Project Contact Information Please provide information on the person to be contacted by NDB Staff regarding electronic submittal, confirmation of receipt, and other correspondence. Name* Alisha Hudson Email Address* ahudson@agriwaste.com Project Information ......................... Application/Document Type* New (Fee Required) Modification - Major (Fee Required) Renewal with Major Modification (Fee Required) Annual Report Additional Information Other Engineering Certification Phone Number* 9193676314 Modification - Minor Renewal GW-59, NDMR, NDMLR, NDAR-1, N DAR-2 Residual Annual Report Change of Ownership We no longer accept these monitoring reports through this portal. Please click on the link below and it will take you to the correct form. https:Hedocs.deq.nc.gov/Forms/NonDischarge Monitori ng_Report Permit Type:* Wastewater Irrigation High -Rate Infiltration Other Wastewater Reclaimed Water Closed -Loop Recycle Residuals Single -Family Residence Wastewater Other Irrigation Permit Number:* WQ0044177 Has Current Existing permit number Applicant/Permittee Address* 3717 National Drive - Suite 209, Raleigh, NC 27612 Facility Name* 1594 NC 50 SFR Please provide comments/notes on your current submittal below. Hello, Happy Friday! I have attached the Final Engineer Certification for 1594 NC Hwy 50, Creedmoor, NC 27522. The system was installed to meet the intent of the design. I will also send a copy via email. Please let me know if you need anything else. Thank you for your time and assistance! At this time, paper copies are no longer required. If you have any questions about what is required, please contact Nathaniel Thornburg at nathaniel.thornburg@ncdenr.gov. Please attach all information required or requested for this submittal to be reviewed here. (Application Form, Engineering Plans, Specifications, Calculations, Etc.) (Stamped) WQ0044177 Engineer Certification Package 7.86M6 (1594 NC 50 SFR).pdf Upload only 1 PDF document (less than 250 MB). Multiple documents must be combined into one PDF file unless file is larger than upload limit. * By checking this box, I acknowledge that I understand the application will not be accepted for pre -review until the fee (if required) has been received by the Non -Discharge Branch. Application fees must be submitted by check or money order and made payable to the North Carolina Department of Environmental Quality (NCDEQ). I also confirm that the uploaded document is a single PDF with all parts of the application in correct order (as specified by the application). Mail payment to: NCDEQ — Division of Water Resources Attn: Non -Discharge Branch 1617 Mail Service Center Raleigh, NC 27699-1617 Signature Submission Date 3/8/2024 AVVr Engineers and Soil Scientists Agri -Waste Technology, Inc. 501 N Salem Street, Suite 203, Apex, NC 27502 agriwaste.com 1 919.859,0669 16 CAR ZO tee - SEAL ~tie,-,i = D24592 I z jzv?-�, March 7, 2024 Mr. Nathaniel D. Thornburg Division of Water Resources NC Department of Environmental Quality 512 N. Salisbury Street Raleigh, NC 27604 Subject: System Installation Final Certification Whispering Pines Farm LLC SFR Wastewater Irrigation System 1594 NC 50, Creedmoor, NC 27522 Granville County Permit No. WQ0044177 Dear Mr. Thornburg; We have completed the installation of the SFR Wastewater Irrigation System for the 5- bedroom single family residence located at 1594 NC 50, Creedmoor, NC 27522. The system was installed by Chris Milko and Michael Brinkley. Agri -Waste Technology, Inc. (AWT) inspected the system during construction and upon completion of the system. Pictures from the inspection are included with this letter. The system was installed to meet the intent of the design. The following documentation is included with this letter: - Engineer's Certification - Inspection Reports - Installer's Certification - Construction Photographs - As -Built Drawing - O&M Agreement Thank you for your assistance. If you have any questions or comments, please feel free to contact me at 919-367-6310 or via email at kdavidsongagriwaste.com Regards; Kevin Davidson, P.E. V.P. of Engineering 1 of 25 Permit No. WQ0044177 Single -Family Residence Wastewater Irrigation System Whispering Pines Farm LLC January 24, 2024 1594 NC 50 SFR Granville County ENGINEERING CERTIFICATION ❑ Partial ® Final I Kevin D. Davidson, P.E. , as a duly licensed North Carolina Professional Engineer, having ® periodically / ❑ fully observed the construction of the permitted facilities, do hereby state to the best of my abilities that the facility was constructed in compliance with G.S. 143-215.1, Administrative Code Title 15A Subchapter 02T, this permit, and the Division -approved plans and specifications. Documentation of any variation to this permit and the Division -approved plans and specifications is in the attached as -built drawings. Description of variations: Kevin D. Davidson, P.E. .ass�ti' SEAL = 424592 f . r � Professional Engineer's Name,+'C�A�RO�+f,,,}} Agri -Waste Technology, Inc. C-0519 Firm Name Firm No. 501 N. Salem Street Suite 203'`. Address Apex NC 27502 City State Zip Code 919-367-6310 kdavidson@agriwaste.com Telephone AL Email Seal, Signature, and Date THE PERMITTEE SHALL SUBMIT THE COMPLETED ENGINEERING CERTIFICATION, INCLUDING ALL SUPPORTING DOCUMENTATION, VIA THE NON -DISCHARGE ONLINE PORTAL. WQ0044177 Version 1.1 Shell Version 230516 Page 9 of 9 2 of 25 AV6Pr Engineers and Soil Scientists Agri -Waste Technology, Inc. 501 N Salem Street, Suite 203, Apex, NC 27502 agriwaste.com 1 919.859,0669 SFR Wastewater Irrigation System Initial Inspection Form Whispering Pines Farm Residence Please consider the following information when installing this SFR Wastewater Irrigation System and preparing the information required for the final Engineer Certification. An Intermediate and Final Inspection (by the certifying Professional Engineer or designated representative) will be required during the system installation. Initial Inspection The initial inspection shall be scheduled during system installation. The approximate state of construction for this inspection is as follows: • Tanks shall be installed and partially backfilled. The Top of Tank shall be left uncovered for inspection. • Tank risers shall be installed and sealed to tank. • All piping between tanks shall be installed. • AdvanTex Treatment Pod installed and plumbed. • Control Panel location shall be marked. • UV Filter Housing installed. • Disc Filter installed (Headworks Unit). • Cleanouts installed (at building). The following items shall be verified and approved by the inspector at the initial inspection: x_ Septic Tank Size (Existing) _x_ Tank Risers x_ Pipe Size/Type x Pump Tank Size _x Tank Testing" x_ Pipe Routing x Treatment Pod Size • Installer to provide documentation of tank testing and results. • Photographs of construction progress shall be taken by the inspector. Comments: Existing Tanks Hydrostatic Leak Tested by Installer 8/4/2023-8/5/2023. Shoaf 1,500-gal Recirculation Tank PT-353, Shoaf 4,000-gal Pump Tank PT-2106, 6" gravel base, level. Pressure Tested onsite (5" Hg for 2 min) and witnessed by Jessi Banks, Isabel Manson, and Catherine Barbee of AWT. Existing Tanks retrofitted with Orenco Risers, cast in riser adapters, Orenco risers on inlet and outlet ends of Recirculation Tank and Pump Tank. Two (2) AX20 Treatment Pods. Alisha R. Hudson Assistant Project Engineer ahudson@agriwaste.com 11/30/2023 Inspector Name and Signature Date of Inspection 3 of 25 AV6Pr Engineers and Soil Scientists Agri -Waste Technology, Inc. 501 N Salem Street, Suite 203, Apex, NC 27502 agriwaste.com 1 919.859,0669 SFR Wastewater Irrigation System Final Inspection Form Whispering Pines Farm Residence Final Inspection The Final inspection shall be scheduled at the completion of the system installation. The following activities shall be accomplished prior to final inspection; • Complete system installation. • Headworks shall be installed and plumbed to components. • Final grading and stabilization. • Electrical connections made. • Water in tank to operate system. • All meter boxes installed. • Dripfield installed. • UV Bulb installed. The following items shall be verified and approved by the inspector at the final inspection: x Safety Nets Installed x Float Switch Elevations x_ System Operational x_ Tank Lids Installed x_ Pump Operational x_ Meter Boxes x Control Panel Installed/Wired x Pump Flowrate x Dripfield Pressures x_ Effluent Filter Installed x_ UV Operational x_ Final Site Grading • Installer to provide pictures taken during construction. • Photographs of the construction progress shall be taken by the inspector. Comments: Startup numbers, installed line lengths, and installation photos included in attached documents. Peter Rhodes (AQWA, Inc.) present at Start Up. Alisha R. Hudson Assistant Project Engineer ahudson@agriwaste.com Inspector Name and Signature 02/27/2024 Date of Inspection 4 of 25 Start Up Sheet Start Up Date: 2/27/2024 Project: Whispering Pines Farm Location: 1594 NC Hwy 50 Creedmoor, NC 27522 County: Granville Operator: AQWA, Inc. Installer: Chris Milko/Michael Brinkley Bedrooms: 5 BDR, 600 GPD Tank Information Size Manufactuer Model No. Septic Tank: EXISTING EXISTING EXISTING Recircualtion Tank: 1,500 Shoaf PT-353 Pump Tank: 4,000 Shoaf PT-2106 Treatment Information System Type: AX20 x 2 Mode: 1A Pod #'s: 336223-1 336223-2 Recirculation Settings Float Settings: TE/LWA TO HWA *Measured from Tank Floor 30.0" 43.0" 45.0" Timer Settings: Normal Override ON (minutes): 0.5 0.5 OFF (minutes): 15.5 7.75 Pump Information: Model No. PF5005-11 Discharge Settings Float Settings: LWA/RO TE PW/HWA *Measured from Tank Floor 27.0" 33.0" 72.0" Timer Settings: Normal Override ON (minutes): 13.55 13.55 OFF (minutes): 224 112 Pump Information: Model No. PF2005-11 Disinfection UV Type: Orenco Amps: 0.34A Control Panel Model No.: VCOM-AX20B2/PT UV RG RTU: RTU149730 Communications Line Run To Panel: YES Does The Line Have Service: NO Notes N/A Top of RSV 39.0" 5 of 25 Project: Whispering Pines Farm Startup Date: 2/27/2024 Location: 1594 NC Hwy 50 Creedmoor, NC 27522 County: Granville Installed Line Lengths and Elevation Shots Daily Design Flow: 600 gal/day Loading Rate (L.T.A.R.): 19.90 in/yr 0.034 gal/day/ft3 Minmum Dispersal Field Area Required: 17,653 ft2 Average Dripline Spacing: 3.2 ft Effective Drainfield Area Installed: 18,589 ft2 Run Length (ft) Blanking Emitter Zone Total (ft) Length (ft) (ft) Zone 1 Laterall 300 0 300 Lateral 271 0 271 Lateral 303 0 303 Lateral 310 0 310 Lateral 269 0 269 1,453 Zone 2 Laterall 277 0 277 Lateral 277 0 277 Lateral 277 0 277 Lateral 282.5 0 282.5 Lateral 282.5 0 282.5 1,396 Zone 3 Laterall 315 0 315 Lateral 315 0 315 Lateral 310 0 310 Lateral 310 40 270 Lateral 307 0 307 1,517 Zone 4 Laterall 309 40 269 Lateral 311 50 261 Lateral 307 16 291 Lateral 309 0 309 Lateral 313 0 313 1,443 TOTAL: 5,809 6 of 25 Project: Whispering Pines Farm Startup Date: 2/27/2024 Location: 1594 NC Hwy 50 Creedmoor, NC 27522 County: Granville Number of zones 4 Zone 1 1453 linear ft drip tubing, not including loops 727 emitters expected 0.61 gph flow per emitter MEASURED 7.39 gpm expected dosing flow 7.8 5 laterals 4.33 gpm flow need for flushing 11.72 gpm Total Flow Per Zone 13.8 Calculated Flushing Velocity (fps) 1.67 Zone 2 1396 linear ft drip tubing, not including loops 698 emitters expected 0.61 gph flow per emitter MEASURED 7.10 gpm expected dosing flow 6.9 5 laterals 3.93 gpm flow need for flushing 11.03 gpm Total Flow Per Zone 13.6 Calculated Flushing Velocity (fps) 1.87 Zone 3 1517 linear ft drip tubing, not including loops 759 emitters expected 0.61 gph flow per emitter MEASURED 7.71 gpm expected dosing flow 7.5 5 laterals 4.16 gpm flow need for flushing 11.87 gpm Total Flow Per Zone 13.5 Calculated Flushing Velocity (fps) 1.67 Zone 4 1443 linear ft drip tubing, not including loops 722 emitters expected 0.61 gph flow per emitter MEASURED 7.34 gpm expected dosing flow 7.2 5 laterals 4.46 gpm flow need for flushing 11.79 gpm Total Flow Per Zone 13.2 Calculated Flushing Velocity (fps) 1.67 7 of 25 AVVT Engineers and Soil Scientists SFR Wastewater Irrigation System Installer Certification Form Agri -Waste technology, Inc. Whispering Pines Farm Residence 501 N Salem Streets Suite 203, Apex, NC 27502 agriwaste.com 1 919.859.0669 Installer Certification: /1 I (Installer Company and Name) �_LL(. certify that the installation of the Whispering Pines Farm Residence SFR Wastewater Irrigation System was under my direct supervision. Further, to the best of my abilities, due care and diligence was used in the construction such that the system was built within substantial compliance and intent of the approved plans and specifications. Any deviation (to the extent there were deviations) from the approved plans is noted below. Comments: Q—VN r � '.-) Cn % � � r- i) I / Al Installer Name and Signa e Date 8of25 AV6Pr Engineers and Soil Scientists Agri -Waste Technology, Inc. 501 N Salem Street, Suite 203, Apex, NC 27502 agriwaste.com i 919,859.0669 SFR Wastewater Irrigation System Construction Photographs Whispering Pines Farm Residence Figure 1. Final Aerial Overview 9of25 Figure 2. Final System Component Overview Figure 3. Construction Overview 10 of 25 n Figure 4. Septic Tank 1 Inlet/Outlet Figure 5. Septic Tank 2 Outlet 11 of 25 August 5, 2023 4:48 PM Edit August 4, 2023 5:03 PM Edit Figure 6. Existing Tank 1 Leak Test August 5, 2023 4:48 PM August 4, 2023 5:08 PM Edit Figure 7. Existing Tank 2 Leak Test 12 of 25 'OR h.- WNFOOOL - Figure 9. Pump Tank Inlet/Outlet 13 of 25 IL Figure 11. Headworks Plumbing 14 of 25 += -t -electrical at I ins re-r r �. fir6ugh mum IM'_ ti "# } supply lines Figure 14. Recirculation Tank Vacuum Testing Figure 15. Pump Tank Vacuum Testing 16of25 [r d SA Figure 16. System Piping ' a ., Figure 17. System Piping 17 of 25 iYL r�'i � % - mm .'•fir. . . GYM �F.C''.T�si*: �:e:'.#1 ^ • i .. Y'S:. _ •i3'`r a .. .. �... � }.1. •�.T. -_I: _ �VdiYi..s']I e.�s '. ' - - Figure 18. Supply/Return Lines Figure 19. Supply/Return Manifolds/Feeder Lines 18 of 25 Figure 20. Field Valve Boxes 19 of 25 Figure 21. Drainfield Zone 1 Figure 22. Drainfield Zone 2 20 of 25 M I r i 6 b a- ri- runs Figure 23. Drainfield Zone 3 Figure 24. Drainfield Zone 4 21 of 25 Figure 25. Control Ponel Wiring 22 of 25 For a Figure 26. Control Panel Figure 27. Control Panel Penetration/Duct Seal 23 of 25 RehE>vant Setbacks Shown X LLIEC X X A%VT WeR 100, Vy X X Porch 100' C 27522 -5035 X X X Z Engineers and Soil Scientists g cP Agri -Waste Technology, Inc. Property dire 50' X"' X�X X 501 N. Salem Street, Suite 203 Apex, North Carolina 27502 ❑I'1SIte Dwe��ir ❑ 15' X�X X X- X X \-X�X� X _ — — — — _ — 919-g859-0669 www.agriwaste.com P o o ' — — — — — — — — — 00000000000000000000000000000 aaaaaa00000000000000000000000 000000000000000000000o V 000000000000 000000000000000o 00000000000 00000000000000000000000000000 00000000000000000000000000000 o0000000000000000000000000000 V o Whispering Pines Farm — — 00 00000000000000000000000000oo0 I o0000000000000000000000000000 site we��irg 100' _ --- — 00000000000000000000000000000 V o00000000000000 00000000000000 0000000000000000000000000000o ALSL 0000000000000000000000000000o 00000000000000000000 'V 0000000000 oo0000000 0000000000 I 0000000000000000000000000000o D AF-SL WWTS -- /.-.-.-.-.I_.-.-._.-.-._.-.-._.-�._.-.-.-.-. JI 9� Client r � , Existing Information: X Tanks �.\ Whispering Pines Farm, LLC I TRACT 1 , \ � 1 \ + / S By DL DL EF � \ 3717 National Drive, Suite 209 Raleigh, HC 7609 I BV O� PLAT BOOK 49 PG. 170 SS cara@trustwellgroup.com � � O N/F. W ISPERING PINES FARM LLC I 1606 HWY 50 / 1 SST � � P A�_ R T Property Information: 1594 INC Hwy 50 REEDMOOR, NC 27522 ,� I o Creedmoor, NC 27522 Granville �r J APN: 0895-15-8039 I � / X I � \ �County PINs 5-01-25-6270, Q 1561918 SQ. FEET ± / X \ X . .. .. 0895-03-24-1613, O q, 03 3.602 ACRES ± I / y\ X LIv 0895-03-24-6618 0895-24-6322 c� 0895-43-1819 \ + S �_ *See Recomb. Survey Bk 53 Pg 1-2 X + PS JHW HW I X 0 5 10 Feet v J m Q CID CO O O I I x X X � \ / + � Q O O \ / + �X X X CO cp tll ill I , x x O � x I x x X _ X X —� A S I X/ �� / + X— �� cv M I X X/ x I X o + / I X X POND 00 I x� x I I X 0 o zz X x /X X �X I X -� I + X X X x X X I I \ 60 EASEMENT ' + X X I I PLAT BOOK 49, PG. 170 x I X X� \ / + x x X \ f� =X�X X + XV \ \ \ X I FOUN X -x / I i + / x x x \ �',S, X 5/8 RIX -- /EXISTING SHED I X IX X o \ I I / - X REV. ISSUED DATE DESCRIPTION DIN 19 i w � FOUND Q: X FOUND X \ � ER 1 " PIPE / / X 5/8" REBAR A_ \ N/F: K „_ IN TREE ROOT FOUND L1 1 " PIPE FOUND 1 "PIPE I PLAT BOOK 16, PG. 177 WPi(ea ................... ...... . • X� ' 1 X \ \ I N/F: WHISPERING PINES FARM 1594A HWY 50 LLC o f TOTAL AREA: + '` I I \ I I CREEDMOOR, NC 27522 APN: 0895-24-1613 :.:.: : `: .p 515561136 u, "i N; u; f 127.551 w �_ _ SQ. FEET ± ACRES ± x I _ _ X `— T zz 00 164 816 S . FEET ± Q 3.784 ACRES ± ,:.:.:::: • :::..:.: ' • m� f / x '` \ I U bQ . • bQ"a f. Well oNo oNo V V i / � \ f � cfl (0 L IV r,3 01 Well"a°"ea ==t N NF: ELLIOTT CONNIE B -141. I •' k �. / 9 C 50 I --: 2 N HWY I x C EEDMO.O•I,NC 275 2 w w \ SHEET TITLE APN: 0895-14-765 w �AS—Bu'dt � I I X X X_ X X + EXISTING I � I X ` X �X _ POND + l � � X� x 1 \ S 82 '30 E 260.1 xI I X X x / DRA H BY: IN A. Hudson CREATED ON: 03/06/2024 Lo -p XI I \ \ RELEASED BY: RELEASED ON: SET 00 SHEET NAME: CO 15/8 REBAR XI So 100 N \ Feet As-Buiolt 24 of 25 State of North Carolina Department of Environmental Quality DWR Division of Water Resources SINGLE-FAMILY RESIDENCE WASTEWATER IRRIGATION SYSTEM Division of Water Resources OPERATION AND MAINTENANCE AGREEMENT FORM: SFRWWIS-O&M 09-18 Permit No. WQOO 44177 County: Granville a f ermittee: Whispering _Pincs Farms, LLC c/o Cara_Zalcberg Hilton (i.e., all deeded property owners) The Permittee agrees to operate and maintain the single-family residence wastewater treatment and irrigation system as follows: 1. Inspect the septic tank annually, and pump out solids as needed. ?. Inspect and clean the septic tank effluent filter annually. (V'applicable) 3. Inspect the tablet chlorinator weekly. Add wastewater grade chlorine tablets (c.g., calcium hypochlorite) as needed. Swimming pool grade chlorine tablets are not acceptable. (if applicable) 4. Inspect the ultraviolet disinfection unit weekly. Clean or replace the lamps and quart.7 sleeves as needed. applicable) S. Inspect all storage tanks, pumps, and alarms monthly. Remove the floating scum layer in all pump/storage tanks when pumping the septic tank solids out. 6. Inspect the spray irrigation system monthly to verify: proper operation of the spray heads; that there are no leaks; that vegetative growth does not obstruct the spray heads: that the irrigated wastewater is not ponding in or running off the designated irrigation area; and that there are no objectionable odors. (df applicable) 7. Inspect the drip irrigation system monthly to verify: proper operation of the drip lines; that there are no leaks; that vegetative growth does not obstruct the drip emitters; that the irrigated wastewater is not ponding in or running off the designated irrigation area; and that there are no objectionable odors, (4,upplicable) R. Maintain a set or Division -approved engineering plans and specifications. 9. Pay the required annual fee. 10. Request renewal of this permit on Division -approved forms no later than 190 days prior to expiration. 11. Sign and provide a Change of Ownership application to any future owner of the single-family residence wastewater treatment and irrigation system for their completion and submission to the Division of Water Resources. We understand the above requirements and agree to these terms as part of the issued permit. Signature: ti 1 c5ev,tlucDate: � Signature: Date: Signature: Signature: Date: Date: Ail deeded property owners shall sign this Operation and Maintenance Agreement FORM: SFRWWI5-O&M 09-18 Page 1 of 1 200 of 210 24i7cdQ�7