Loading...
HomeMy WebLinkAboutNCG050450_Representative Outfall Status Initial Request_20240308 USE Division of Energy, Mineral & Land Resources Date Received USE Year Month Day ^. Stormwater Program National Pollutant Discharge Elimination System FOR AGENCY ONLY Environmental REPRESENTATIVE OUTFALL STATUS (ROS) Quality REQUEST FORM If a facility is required to sample multiple discharge locations with very similar storm water discharges, the permittee may petition the Director for Representative Outfall Status(ROS). DEQ may grant Representative Outfall Status if storm water discharges from a single outfall are representative of discharges from multiple outfalls. Approved ROS will reduce the number of outfalls where analytical sampling requirements apply. If Representative Outfall Status is granted,ALL outfalls are still subject to the qualitative monitoring requirements of the facility's permit—unless otherwise allowed by the permit(such as NCG020000)and DEQ approval. The approval letter from DEQ must be kept on site with the facility's Stormwater Pollution Prevention Plan. The facility must notify DEQ in writing if any changes affect representative status. For questions, please contact the DEQ Regional Office for your area (see page 3). (Please print or type) 1) Enter the permit number to which this ROS request applies: Individual Permit (or) Certificate of Coverage N C S N 0 0 0 5 0 4 5 0 2) Facility Information: Owner/Facility Name Southern Pipe, Inc. Facility Contact Bryan Mitchell Street Address 135 Random Dr City New London State NC ZIP Code 28127 County Stanly E-mail Address bryan@southern-pipe.com Telephone No. 704 463-5202 Fax: 3) List the representative outfall(s) information (attach additional sheets if necessary): Outfall(s) East Outfall,Outfall#1 is representative of Outfall(s) West Outfall,Outfall#2 Outfalls' drainage areas have the same or similar activities? ❑ Yes ❑ No Outfalls' drainage areas contain the same or similar materials? o Yes o No Outfalls have similar monitoring results? ❑ Yes ❑ No ❑ No data* Outfall(s) is representative of Outfall(s) Outfalls' drainage areas have the same or similar activities? ❑ Yes o No Outfalls' drainage areas contain the same or similar materials? ❑ Yes ❑ No Outfalls have similar monitoring results? o Yes o No o No data* Outfall(s) is representative of Outfall(s) Outfalls' drainage areas have the same or similar activities? o Yes ❑ No Outfalls' drainage areas contain the same or similar materials? ❑ Yes ❑ No Outfalls have similar monitoring results? ❑ Yes ❑ No o No data* *Non-compliance with analytical monitoring prior to this request may prevent ROS approval. Specific circumstances will be considered by the Regional Office responsible for review. Page 1 of 3 Page 1 of 9 SWU-ROS-2009 Last revised 12/30/2009 Representative Outfall Status Request 4) Detailed explanation about why the outfalls above should be granted Representative Status: (Or, attach a letter or narrative to discuss this information.) For example,describe how activities and/or materials are similar. see attached 5) Certification: North Carolina General Statute 143-215.6 B(i) provides that: Any person who knowingly makes any false statement,representation,or certification in any application, record, report, plan,or other document filed or required to be maintained under this Article or a rule implementing this Article;or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case U_UCr this Article;U..WLU falsifies,tampers with,or L_VW:_g1y .C_UCrD inaccurate any recording or monitoring UCV:LC or method required to be operated or maintained under this Article or rules of the[Environmental Management] Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars($10,000). I hereby request Representative Outfall Status for my NPDES Permit. I understand that ALL outfalls are still subject to the qualitative monitoring requirements of the permit, unless otherwise allowed by the permit and regional office approval. I must notify DEQ in writing if any changes to the facility or its operations takes nitres aftar Roc is granted that may affPrt thic ctatiic If Rf1C nn InngPr annliac I iinriprctanri I miict resume monitoring of all outfalls as specified in my NPDES permit. I certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Signing: Bryan Mitchell Title: President (Signature of Ap14A-1 1 (Date Signed) Please note: This application for Representative Outfall Status is subject to approval by the NCDEQ Regional Office. The Regional Office may inspect your facility for compliance with the conditions of the permit prior to that approval. Final Checklist for ROS Request This application should include the following items: e / This completed form. d' Letter or narrative elaborating on the reasons why specified outfalls should be granted representative status, unless all information can be included in Question 4. o/ Two (2)copies of a site map of the facility with the location of all outfalls clearly marked, including the drainage areas, industrial activities, and raw materials/finished products within each drainage area. d Summary of results from monitoring conducted at the outfalls listed in Question 3. 2( Any other supporting documentation. Page 2 of 3 2 of 9 SWU-ROS-2009 Last revised 12/30/2009 Representative Outfall Status Request Mail the entire package to: NCDEQ DEMLR at the appropriate Regional Office (See map and addresses below) Notes The submission of this document does not guarantee Representative Outfall Status (ROS)will be granted as requested. Analytical monitoring as per your current permit must be continued, at all outfalls, until written approval of this request is granted by DEQ. Non-compliance with analytical monitoring prior to this request may prevent ROS approval. Specific circumstances will be considered by the Regional Office responsible for review. For questions, please contact the DEQ Regional Office for your area. Win • Sale 1� s/L „ r \ 9 \F etterille 1 ' �+=v✓�� Wil , ngton Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Washington Regional Office 943 Washington Square Mall Phone (828) 296-4500 Washington, NC 27889 FAX (828) 299-7043 Phone (252) 946-6481 Fayetteville Regional Office FAX (252) 975-3716 Systel Building, 225 Green St., Suite 714 Wilmington Regional Office Fayetteville, NC 28301-5094 127 Cardinal Drive Extension Wilmington, NC 28405 Phone (910) 433-3300 FAX 910/ 486-0707 Phone (910) 796-7215 FAX (910) 350-2004 Mooresville Regional Office 610 East Center Ave. Winston-Salem Regional Office Mooresville, NC 28115 585 Waughtown Street Winston-Salem, NC 27107 Phone (704) 663-1699 Phone (336) 771-5000 FAX (704) 663-6040 Water Quality Main FAX (336) 771-4630 Raleigh Regional Office Central Office 1628 Mail Service Center 1612 Mail Service Center Raleigh, NC 27699-1628 Raleigh, NC 27699-1612 Phone (919) 791-4200 Phone (919) 807-6300 FAX (919) 571-4718 FAX (919) 807-6494 Page 3 of 3 3 of 9 SWU-ROS-2009 Last revised 12/30/2009 Alpha EC LLC lkiiiie Southern Pipe Representative Outfall Status (ROS) Request 4) Detailed explanation about why the outfalls above should be granted Representative Status: (Or, attach a letter or narrative to discuss this information.) For example, describe how activities and/or materials are similar. Southern Pipe has two outfalls, as shown in the Site Map. Most of the stormwater from Sothern Pipe is diverted to Outfall #1, on the east side of the property. This includes all the stormwater from building 1, railcar unloading, shipping and receiving, and outside storage areas. The stormwater from the roof of Building 2 and employee parking from building 2 flow to Outfall #2. However, the majority of stormwater flowing to Outfall #2 is from a neighbor company called Fiber Composites, LLC dba Fiberon. Fiberon has diverted the majority of their stormwater to a culvert North of the driveway to the Ram building, #13 on the Site Map. The stormwater traverses under the road and discharges at#18 and exits the property at Outfall #2 (#17 on the Site Map). Stormwater Outfall #1, East Outfall, 35.415830, -80.211670 Stormwater Outfall #2, West Outfall, 35.416940, -80.214720 Industrial activities, and raw materials/finished products within each drainage area The primary SIC code for SP is 3084— Plastic Pipe, and their NACIS code is 326122 - Plastics Pipe and Pipe Fitting Manufacturing. Virtually all materials are stored indoors or in storage silos. As necessary, finished products are stored outdoors in designated, paved areas. Rail Car Unloading occurs in an outdoor process area. The stormwater for these areas flows to Outfall #1. Building#2, houses compounding, warehouse storage, and offices. The compounding is done within the building and piped out through the side of the building to the silos near Building 1. Stormwater which contacts the outside of these pipes flows to Outfall #1. The stormwater which contacts the loading docks at Building#2 flow to outfall #1. 919-980-1512 Page 1 of 2 scato@alpha-e.us 4 of 9 Alpha EC LLC lkiiiiie Fiberon catch basin North of#14 on the map. In 2023, Fiberon modified their catch basin North of#14 on the map. As stated above, almost all of the stormwater from Fiberon flows into the catch basin North of#14 on the map. The stormwater flows into a pipe under the road and out at#18. if'-, 5'. JY'T (� �' �r\LG\P %tip y `N ��`' �, + x' �h Y� J i, ..� -v rr 1 ;Cl Jksti'f ` . SM '% n ,,,P - • .. TT \��- .. t Jl. gig•• - 4--- "...'. . '---3 -3 - —INC .s-,".'1,, , :at %,' ,:i.x‘-vtlit:,..1,1•:,C.-:,\:, Pc.,. ',-;"'' ._ ' ' '- ... 14 i 'f. ,, -' 't Y I N�,1 " .,+ r d`y"d"eL 1 ,, 4 ftfti I yr `l. -04.r.+} , ''. F ti� lm' c�`}y _ . : ; h ""er tea o. ti.Y •,4. t,'4� IrvT q,t {•4 0 . r' ' "' ( 4"4.--a1y, ' .3 f•- h �. v",'" t "K 1�b� \ �1•Ii''"'''f+♦l ..-.�, P `t ! 4,0 4404„ --, k s r e a ;"'s ti µµ • d% � 1 7�-•-- .. ,yi` 1 1 'FT *fi t t, +"'.''_� • — 919-980-1512 Page 2 of 2 scato@alpha-e.us 5 of 9 Site Map Southern Pipe, New London, Stanly Copunty NC ;'Mit dal:-, ;J.; •-..:-.----- - • - '' .•.'N...., . l.-' -; '' -.-..............\ - ---- • 1, y ,' I " P, 0 - — I _fir r l. 1 Stormwater ow • - -• , `-] Fisberonl '� ;• ` flow •- �'�' I, - Facility Inspection refer- _- . i T . N ' �.. 14 • , .� ence points INM -,^ `. - ,-, • -7)4 . - 4- Dry !� Dom Stormwater Control ilk 4 e. • •V MR I� r: t .,. ..f Measure I ;\ *ti• f J :_ { }Facility descriptor 114 • f ! 4. ,rii' .-,„,,A-- ce" yr. �.- ! 0' , • / 1,,, n ,•- .. ' - .--T {Building 1 • Storage ' �— eg nd - Area CI) r . - — { :- .1.CO 41E0 4-• .k y Silo Storage} -►".. LLL Shipping I 4 ;►., ;,: Railway y., {Building 2} ,. j, _ Railcar - • r CD RAM Bldgz :� :. .,.a - G _— Storage , :Vim -��—_ Areal , Outfall I, az �^ 4 j O • fill ' � 1 I . Outjall ���' }q} �� ft Google Earth F. 'ter N . .lit I i�L L I I 6 of 9 Southern Pipe Stormwater Flow Coordinates # Coordinates Description 1 35.4169, -80.2113 Top of ditch that runs along the driveway connecting both buildings. 2 35.4172, -80.2124 End of railroad tracks where pipe runs under road leading to creek. 3 35.4171, -80.2113 Beginning of ditch on South side of railroad tracks where parking lot water and some pipe yard water merge. 4 35.4168, -80.2123 Flow that runs into beginning of creek from culvert. 5 35.4166, 80.2123 Small ditch by sewer station for Ram building that runs into creek. 6 35.4164, -80.2109 Middle of pipe yard which runs off slab toward woods. 7 35.4160, -80.2107 Back of pipe yard which runs off slab toward woods. 8 35.4168, -80.2123 Where underground culvert discharges to creek. 9 35.4178, -80.2123 Back parking lot where silos are. 10 35.4174, -80.2127 Ram building driveway near grate. 11 35.4175, -80.2133 Ram building driveway west side of bay door. 12 35.4171, -80.2141 Parking lot side of warehouse (ditch that runs to gulley.) 13 35.4177, -80.2139 Driveway for Ram building between 2 ravines. 14 35.4182, -80.2145 Driveway for Ram building going downhill as you leave Austin Road. 15 35.4159, -80.2117 Property line at creek. Dry basin with rip rap built to slow water flowing into pond. (East Outfall, Outfall #1) 16 35.4169, -80.2143 Ram building roof drain discharge into ravine. (West Outfall, Outfall #2) 17 35.4169, -80.2149 Property line on west side. 18 35.4182 80.2144 Culvert under road discharging stormwater from neighbor (Fiber Composites, LLC dba Fiberon) 919-980-1512 Page 2 of 2 scato@alpha-e.us 7 of 9 Site Map Southern Pipe, New London, Stanly Copunty NC ;'Mit dal:-, ;J.; •-..:-.----- - • - '' .•.'N...., . l.-' -; '' -.-..............\ - ---- • 1, y ,' I " P, 0 - — I _fir r l. 1 Stormwater ow • - -• , `-] Fisberonl '� ;• ` flow •- �'�' I, - Facility Inspection refer- _- . i T . N ' �.. 14 • , .� ence points INM -,^ `. - ,-, • -7)4 . - 4- Dry !� Dom Stormwater Control ilk 4 e. • •V MR I� r: t .,. ..f Measure I ;\ *ti• f J :_ { }Facility descriptor 114 • f ! 4. ,rii' .-,„,,A-- ce" yr. �.- ! 0' , • / 1,,, n ,•- .. ' - .--T {Building 1 • Storage ' �— eg nd - Area CI) r . - — { :- .1.CO 41E0 4-• .k y Silo Storage} -►".. LLL Shipping I 4 ;►., ;,: Railway y., {Building 2} ,. j, _ Railcar - • r CD RAM Bldgz :� :. .,.a - G _— Storage , :Vim -��—_ Areal , Outfall I, az �^ 4 j O • fill ' � 1 I . Outjall ���' }q} �� ft Google Earth F. 'ter N . .lit I i�L L I I 8 of 9 Southern Pipe Stormwater Flow Coordinates # Coordinates Description 1 35.4169, -80.2113 Top of ditch that runs along the driveway connecting both buildings. 2 35.4172, -80.2124 End of railroad tracks where pipe runs under road leading to creek. 3 35.4171, -80.2113 Beginning of ditch on South side of railroad tracks where parking lot water and some pipe yard water merge. 4 35.4168, -80.2123 Flow that runs into beginning of creek from culvert. 5 35.4166, 80.2123 Small ditch by sewer station for Ram building that runs into creek. 6 35.4164, -80.2109 Middle of pipe yard which runs off slab toward woods. 7 35.4160, -80.2107 Back of pipe yard which runs off slab toward woods. 8 35.4168, -80.2123 Where underground culvert discharges to creek. 9 35.4178, -80.2123 Back parking lot where silos are. 10 35.4174, -80.2127 Ram building driveway near grate. 11 35.4175, -80.2133 Ram building driveway west side of bay door. 12 35.4171, -80.2141 Parking lot side of warehouse (ditch that runs to gulley.) 13 35.4177, -80.2139 Driveway for Ram building between 2 ravines. 14 35.4182, -80.2145 Driveway for Ram building going downhill as you leave Austin Road. 15 35.4159, -80.2117 Property line at creek. Dry basin with rip rap built to slow water flowing into pond. (East Outfall, Outfall #1) 16 35.4169, -80.2143 Ram building roof drain discharge into ravine. (West Outfall, Outfall #2) 17 35.4169, -80.2149 Property line on west side. 18 35.4182 80.2144 Culvert under road discharging stormwater from neighbor (Fiber Composites, LLC dba Fiberon) 919-980-1512 Page 2 of 2 scato@alpha-e.us 9 of 9