HomeMy WebLinkAboutNCG030325_DMR_20200720 409 Rogers View Court
Mid Atlantic Raleigh. 27610
9
office 919.2.2 50 9918
Engineering& Environmental Solutions facsimile 919.250 9950
MAAONLINE.COM
June 29, 2020
NCDEQ/DWR RECEIVED
Attention: Central Files
1617 Mail Service Center JUL 2 0 2020
Raleigh, North Carolina 27699-1617 CENTRAL FILES
DWR SECTIC;.'
Subject: STORMWATER SAMPLING RESULTS
SALEM STEEL
1725 VALGRAVE STREET
WINSTON-SALEM, FORSYTH COUNTY, NORTH CAROLINA
PERMIT NCG030325
MID-ATLANTIC JOB NO. 000R2951.10
Dear Sir/Madam:
Attached please find the Stormwater Discharge Monitoring Reports (DMR) and analytical
report for the sampling conducted at the above-referenced site. A stormwater sample was
collected from Outfall 001 and 002 on Jun 10, 2020 and analyzed for total suspended
solids pH, lead (Pb), copper (Cu), zinc, (Zn), (TSS) and oil and grease (O&G). As indicated
on the attached DMR, all parameters were reported below or within their respective
benchmark values. If you have any questions or need additional information, please
contact me at 919-250-9918.
Sincerely,
MID-ATLANTIC ASSOCIATES, INC.
AicAree
Paul W. Spangenberg
Director of Environmental Compliance Services
Attachments: Stormwater Discharge Monitoring Report
Laboratory Analytical Report
EXPERIENCED CUSTOMER FOCUSED INNOVATIVE
RAIN EVENT DATA
FACILITY: Structural Steel of Carolina— Salem Steel
ADDRESS: 1720 Vargrave Street
Winston-Salem, NC 27107
CONTACT: Chris Wolf TELEPHONE: (336) 725-0521
STORM EVENT INFORMATION
DATE YEAR MONTH DAY
2020 6 16
HOURS MINUTES
DURATION
48 0
PRECIP.
AMOUNT (IN.)
1.17
RUNOFF
VOL. (M/GAL.) 0.28
DAYS HOURS
PRECEDING -
EVENT
3 0
PRINCIPLE EXECUTIVE OFFICER OR AUTHORIZED AGENT
PRINT SIGNATURE DATE
Paul W. Spangenberg Olefidely
000
6/16/20
9 Acres x 43,560 (Sq. Ft.) = 392040 x 1.17 = 458686.8 x .0833 = 38208.6 x 7.48 = 1285800.4/ 1000000= 0.28 mg
Stormwater Discharge Monitoring Report
for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCGOSPOIMN.NNED
Date submitted 6/25/20
JAN 21 2021
CERTIFICATE OF COVERAGE NO. NCGO3 0 3 2 0 SAMPLE COLLECTION YEAR 2020 _ C,n h.i�
FACILITY NAME Structural Steel of Carolina-Salem Steel
SAMPLE PERIOD 0 Jan-June E July-Dec `t�
COUNTY Forsyth or ❑ Monthly' (month)
PERSON COLLECTING SAMPLES Chris Wolf DISCHARGING TO CLASS ❑ORW fHQW ❑Trout ❑PNA
LABORATORY Con-test Lab Cert.# 652 ❑Zero-flow ❑Water Supply ESA
Comments on sample collection or analysis: *Other
- PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 -
Part A: Stormwater Benchmarks and Monitoring Results
n No discharge this period?2
Date Sample 24-hour rainfall pH, Non Polar O&G/ Total Toxic
Outfall No. Collected' amount, Total Suspended Solids Standard units Total Copper Total Lead Total Zinc Total Petroleum Organicss
- (mo/dd/yr) Inches3 Hydrocarbons
Benchmarks _ - 100 mg/L or 50 mg/L4 6.0—9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L
Parameter Code - 46529 C0530 00400 01119 01051 01094 00552 78141
01 6/16/20 1.17 3.3 6.9 0.0041 0.010 0.76 <0.99 N/A
02 6/16/20 1.17 52 6.9 0.0069 0.024 0.083 <2.0 N/A
1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall.
2 For sampling periods with no discharge at any single outfall,you must still submit this discharge monitoring report with a checkmark here.
'The total precipitation must be recorded using data from an on-site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement.
'See General Permit, Section B,Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies.
'Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture
electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA
Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11;for semiconductor
manufacture use the definition as found in 40 CFR 469.12;for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray
tube manufacture use the definition found in 40 CFR 469.31).
Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018
Page 1 of 3
Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify,and the requirement for TTO monitoring
may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General
Permit. For those facilities electing to employ the TTO monitoring waiver,the discharger shall sign the following certification statement:
"Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics
(TTO), I certify that to the best of my knowledge and belief,no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or
stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the
solvent management plan included in the Stormwater Pollution Prevention Plan."
Chris Wolf
Name(Print name)
Safety Manager
Title(Print title)
_ u) 7 ( SfZO
Signature Date
Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL,<PQL, Non-detect, ND, or other similar non-numerical
format. When results are below the applicable limits,they must be reported in the format,"<XX mR/L",where XX is the numerical value of the detection
limit, reporting limit,etc. in mg/L.
Note: If you report a sample value in excess of the benchmark,you must implement Tier 1, Tier 2,or Tier 3 responses. See General Permit text.
Part B: Vehicle Maintenance Area Monitoring Results:only for facilities averaging> 55 gal of new oil per month.
n No discharge this period?2
OutfaII No. Date Sample Collected' 24-hour rainfall amount, New Motor Oil or Non-Polar O&G/Total Total Suspended
(mo/dd/yr) Inches3 Hydraulic Oil Usage Petroleum Hydrocarbons Solids
Benchmarks - - - 15 mg/L 100 mg/L or 50 mg/L4
Parameter Code - 46529 NCOIL 00552 C0530
Footnotes from Part A also apply to Part B
Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2,or Tier 3 responses. See Genera!Permit text.
Permit Date:11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018
Page 2 of 3
FOR PART A AND PART B MONITORING RESULTS:
• A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES Q NO Q
IF YES,HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE? YES❑ NO 0
REGIONAL OFFICE CONTACT NAME:
Mail an original copy of this DMR, including all"No Discharge"reports, within 30 days of receipt of the lab results(or at end of monitoring period in the
case of"No Discharge"reports)to:
Division of Water Quality
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED:
"I certify, under penalty of law,that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to
assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or
those persons directly responsible for gathering the information,the information submitted is,to the best of my knowledge and belief,true,accurate,and complete. I
am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations."
k.)W6 110 IZo
Signature of Permittee Date
Permit Date:11/1/2018-05/31/2021 SWU-245,last revised 11/1/2018