Loading...
HomeMy WebLinkAboutSW3240302_Design Calculations_20240307 ENGINEERING CALCULATIONS FOR THE PRESERVE AT FOREST CREEK - PHASE 2 WAXHAW, UNION COUNTY, NORTH CAROLINA Waxhaw Ventures, LLC. 1101 South Blvd. #106 Charlotte, NC 28203 February 16, 2024 LandDesign Project #: 1021143 Calculated By: FJM c SEAL - 037773 9jL FNGINE6f .P���� 02/16/2024 LandDesign TABLE OF CONTENTS . PROJECT NARRATIVE.........................................................................................4 • SOILS MAP............................................................................................................8 • FEMA FIRM MAP ................................................................................................13 USGSMAPS........................................................................................................15 • SEDIMENT BASIN CALCULATIONS..................................................................18 • SB-1 CALCULATIONS.................................................................................................................20 • SB-2 CALCULATIONS.................................................................................................................25 • SB-3 CALCULATIONS.................................................................................................................30 • SB-4 CALCULATIONS.................................................................................................................38 • SB-5 CALCULATIONS.................................................................................................................43 • S13-6 CALCULATIONS.................................................................................................................51 • S13-7 CALCULATIONS.................................................................................................................60 • S13-8 CALCULATIONS.................................................................................................................65 • SB-9 CALCULATIONS.................................................................................................................71 • SB-10 CALCULATIONS...............................................................................................................78 • SB-11 CALCULATIONS...............................................................................................................82 • SB-12 CALCULATIONS...............................................................................................................89 • SB-13 CALCULATIONS...............................................................................................................93 • SB-14 CALCULATIONS.............................................................................................................101 SB-15 CALCULATIONS.............................................................................................................106 • SB-16 CALCULATIONS.............................................................................................................110 • SB-17 CALCULATIONS.............................................................................................................117 • SB-18 CALCULATIONS.............................................................................................................121 . SB-19 CALCULATIONS.............................................................................................................127 • SB-20 CALCULATIONS.............................................................................................................133 • SB-21 CALCULATIONS.............................................................................................................137 • SB-22 CALCULATIONS.............................................................................................................143 • SB-23 CALCULATIONS.............................................................................................................150 • SB-24 CALCULATIONS.............................................................................................................156 • SB-25 CALCULATIONS.............................................................................................................163 • SB-26 CALCULATIONS.............................................................................................................170 • SB-27 CALCULATIONS.............................................................................................................175 • TEMPORARY DITCH MATTING-SPEC SHEET.....................................................................180 • PRE DEVELOPED CALCULATIONS................................................................181 • POST DEVELOPED CALCULATIONS..............................................................212 • BMP-7 WATER QUALITY CALCULATIONS.............................................................................215 • BMP-7 CALCULATIONS............................................................................................................234 • BMP-8 WATER QUALITY CALCULATIONS.............................................................................258 • BMP-8 CALCULATIONS............................................................................................................277 • BMP-9 WATER QUALITY CALCULATIONS.............................................................................301 • BMP-9 CALCULATIONS............................................................................................................323 • BMP-10 WATER QUALITY CALCULATIONS...........................................................................350 • BMP-10 CALCULATIONS..........................................................................................................372 • BMP-11 WATER QUALITY CALCULATIONS...........................................................................399 • BMP-11 CALCULATIONS..........................................................................................................421 • BMP-12 WATER QUALITY CALCULATIONS...........................................................................448 • BMP-12 CALCULATIONS..........................................................................................................467 • BUOYANCY CALCULATIONS ..........................................................................491 • RIP RAP CALCULATIONS................................................................................504 • ON SITE STORM DRAINAGE...........................................................................518 • SPREAD CALCULATIONS........................................................................................................519 • 10 YEAR CALCULATIONS........................................................................................................525 • 25 YEAR CALCULATIONS........................................................................................................539 • PLAN VIEWS.............................................................................................................................553 • CULVERT/DITCH CALCULATIONS..................................................................560 • CULVERT#1 CALCULATIONS.................................................................................................561 • CULVERT#2 CALCULATIONS.................................................................................................572 • CULVERT#3 CALCULATIONS .................................................................................582 • DIVERSION DITCH CALCULATIONS .........................................................................584 Project Narrative: The Preserve at Forest Creek- Phase 2 LDI Project No. 1021143 Developer: Waxhaw Ventures, LLC. 1101 South Blvd. #106 Charlotte, NC 28203 Project Description: The following calculations have been performed in support of the construction of The Preserve at Forest Creek- Phase 2 Single-Family Residential Development. The project is zoned CD-R4-PRD (CD) (Conditional District Single-Family Planned Residential) in Waxhaw, NC. The construction will include installation of new buildings, associated utilities, storm drainage, wet pond, and offsite roadway improvements. Soils Information: The predominant soils for this site are CeB2 CeC2, and AeB. The site soils map showing detailed locations is included. For design purposes, "B"was chosen as the hydrologic soil group. Erosion Control: Silt fence will be used around the site to prevent sediment from entering adjacent properties and the existing creeks. A temporary diversion ditches and skimmer sediment basins will be installed within the site to prevent sediment from entering the storm drainage system until the areas around them have been stabilized. A total of 69.30 ac will be cleared. Temporary Ditch Summary: All temporary ditches to be lines with American Green SC250 or equal. TEMPORARY TEMPORARY TEMPORARY TEMPORARY DITCH Velocity(ft/s) DITCH Velocity(ft/s) DITCH Velocity(ft/s) DITCH Velocity(ft/s) TD-1A Ditch 5.96 TD-61)Ditch 4.92 TD-13D Ditch 3.9 TD-22A Ditch 6.5 TD-113 Ditch 5.4 TD-7A Ditch 7.14 TD-14A Ditch 4.58 TD-22B Ditch 6.37 TD-2A Ditch 3.31 TD-76 Ditch 6.57 TD-14B Ditch 4.74 TD-22C Ditch 4.26 TD-213 Ditch 11.65 TD-8A Ditch 4.84 TD-15A Ditch 6.08 TD-23A Ditch 3.96 TD-3A Ditch 5.87 TD-86 Ditch 3.13 TD-16A Ditch 3.15 TD-23B Ditch 6.87 TD-313 Ditch 7.76 TD-9A Ditch 5.75 TD-16B Ditch 11.58 TD-23C Ditch 6.03 TD-3C Ditch 5.66 TD-96 Ditch 4.13 TD-16C Ditch 6.23 TD-24A Ditch 4.01 TD-4A Ditch 5.72 TD-9C Ditch 3.75 TD-17A Ditch 6.34 TD-24B Ditch 3.88 TD-413 Ditch 9.78 TD-10A Ditch 11.32 TD-18A Ditch 3.36 TD-24C Ditch 6.27 TD-5A Ditch 9.21 TD-11A Ditch 5.38 TD-18B Ditch 10.7 TD-25A Ditch 7.88 TD-513 Ditch 5.78 TD-116 Ditch 2.91 TD-19A Ditch 5.24 TD-25B Ditch 10.43 TD-5C Ditch 4.76 TD-11C Ditch 5.14 TD-19B Ditch 8.92 TD-25C Ditch 3.76 TD-51)Ditch 4.76 TD-12A Ditch 4.89 TD-19C Ditch 3.97 TD-26A Ditch 4.85 TD-6A Ditch 5.09 TD-13A Ditch 3.47 TD-20A Ditch 3.4 TD-26B Ditch 3.4 TD-613 Ditch 2.93 TD-13B Ditch 1.97 TD-21A Ditch 3.28 TD-27A Ditch 4.68 TD-6C Ditch 4.92 TD-13C Ditch 1.7 TD-21B Ditch 2.81 TD-27B Ditch 3.4 Pre-Developed Drainage: The existing storm water collection system consists of sheet flow, shallow concentrated, and open channel flow across the entire site. Pre-Development TOC and CN Values: • BMP 7 0 BMP 10 o TOC: 17.9 Minutes o TOC: 22.0 Minutes o CN: 50 o CN: 55 • BMP 8 • BMP 11 o TOC: 14.6 Minutes o TOC: 18.5 Minutes o CN: 55 o CN: 55 • BMP 9 • BMP 12 o TOC: 18.6 Minutes o TOC: 18.5 Minutes o CN: 51 o CN: 55 Post-Developed Drainage: The proposed storm water collection system will consist of drainage swales and multiple wet ponds within the project boundaries. The storm system was designed to detain the 10 and 25 year storm events and to have a minimum of 85% average annual removal for Total Suspended Solids and 40% average annual removal for Total Phosphorus. Proposed water quality/channel protection/detention requirements are being met according to the NCDEQ Requirements. Post-Development TOC and CN Values: • BMP 7 0 BMP 10 o TOC: 5.0 Minutes o TOC: 5.0 Minutes o CN: 87 o CN: 87 • BMP 8 0 BMP 11 o TOC: 5.0 Minutes o TOC: 5.0 Minutes o CN: 87 o CN: 87 • BMP 9 0 BMP 12 o TOC: 5.0 Minutes o TOC: 5.0 Minutes o CN: 87 o CN: 82 Stormwater Detention Summary: Wet Pond 7 Wet Pond 8 Wet Pond 9 Wet Pond 10 Wet Pond 11 Wet Pond 12 Combined Drainage Area Total 14.23 ac 16.37 ac 18.63 ac 12.04 ac 7.49 ac 8.29 ac 77.05 ac Q2(Pre-Developed) 1.06 cfs 4.39 cfs 1.64 cfs 2.50 cfs 1.74 cfs 1.93 cfs 13.26 cfs Q1 o(Pre-Developed) 9.48 cfs 18.62 cfs 11.94 cfs 10.96 cfs 7.55 cfs 8.37 cfs 66.92 cfs Q25(Pre-Developed) 17.46 cfs 30.26 cfs 21.58 cfs 17.90 cfs 12.29 cfs 13.63 cfs 113.12 cfs Q2(Post-Developed) 0.92 cfs 3.75 cfs 1.24 cfs 1.71 cfs 1.45 cfs 1.82 cfs 10.89 cfs Detained Detention Release Quo(Post-Developed) 8.32 cfs 15.94 cfs 7.78 cfs 8.18 cfs 6.55 cfs 7.98 cfs 54.75 cfs Detained Detention Release Q25(Post-Developed) 16.00 cfs 27.49 cfs 14.75 cfs 11.78 cfs 11.13 cfs 13.61 cfs 94.76 cfs Detained Detention Release Wet Pond 7 Wet Pond 8 Wet Pond 9 Wet Pond 10 Wet Pond 11 Wet Pond 12 Q2 (Post-Developed vs. Pre- 0.92< 1.06 3.75< 4.39 1.24< 1.64 1.71 < 2.50 1.45< 1.74 1.82 < 1.93 Developed) Q,o (Post-Developed vs. Pre- 8.32< 9.48 15.94< 18.62 7.78< 11.94 8.18< 10.96 6.55< 7.55 7.98< 8.37 Developed) Q25 (Post-Developed vs. Pre- 16.00< 17.46 27.49< 30.26 14.75< 21.58 11.78< 17.90 11.13< 12.29 13.61< 13.63 Developed) Conclusion: The engineering analysis presented herein this document demonstrates the ability of the Wet Ponds to meet the design requirements. The calculations show the Wet Pond has sufficient volume to meet the NCDEQ's requirements for BMPs. Moreover, the routing calculations show the Wet Ponds ability to detain flows to pre-developed rates. Soils Map: Hydrologic Soil Group—Union County, North Carolina 3 N � (Forest Creek) a M oo g 520600 521000 521400 521800 522200 522500 523000 523400 523800 524200 524600 525000 5Q� 34°55 29"N ^� ®i q_ ri _ 34°55'29"N cAN�SSS2 F + - , Ali- a 0 Ec� e o 34°53'53"N 34°53 S3"N 520600 521000 521400 521800 522Z00 522600 523000 523400 523800 524200 524600 525000 3 3 c+ Map Scale:1:20,700 if printed on A landscape(11"x 8.5")sheet Meters $ N 0 300 600 1200 1800 $ Feet 0 1000 2000 4000 6000 Map projection:Web Mercator Comer coordinates:WGS84 Edge tics:UTM Zone 17N WGS84 USDA Natural Resources Web Soil Survey 3/10/2021 Conservation Service National Cooperative Soil Survey Page 1 of 4 Hydrologic Soil Group—Union County,North Carolina (Forest Creek) MAP LEGEND MAP INFORMATION Area of Interest(AOI) p C The soil surveys that comprise your AOI were mapped at Area of Interest(A01) 0 C/D 1:24,000. Soils Please rely on the bar scale on each map sheet for map Soil Rating Polygons ■ D measurements. 0 A p Not rated or not available Source of Map: Natural Resources Conservation Service 0 A/D Water Features Web Soil Survey URL: Streams and Canals Coordinate System: Web Mercator(EPSG:3857) 0 B Transportation Maps from the Web Soil Survey are based on the Web Mercator 0 B/D projection,which preserves direction and shape but distorts Rails distance and area.A projection that preserves area,such as the 0 C •.i Interstate Highways Albers equal-area conic projection,should be used if more 0 C/D US Routes accurate calculations of distance or area are required. 0 This product is generated from the USDA-NRCS certified data as D Major Roads of the version date(s)listed below. Not rated or not available Local Roads Soil Survey Area: Union County, North Carolina Soil Rating Lines Background Survey Area Data: Version 20,Jun 3,2020 0 A Aerial Photography Soil map units are labeled(as space allows)for map scales • A/D 1:50,000 or larger. .v B Date(s)aerial images were photographed: Jul 18,2011—Nov 25,2017 .y B/D The orthophoto or other base map on which the soil lines were . r C compiled and digitized probably differs from the background . r C/D imagery displayed on these maps.As a result,some minor shifting of map unit boundaries may be evident. . r D w Not rated or not available Soil Rating Points O A 0 A/D ■ B ■ B/D USDA Natural Resources Web Soil Survey 3/10/2021 Conservation Service National Cooperative Soil Survey Page 2 of 4 Hydrologic Soil Group-Union County, North Carolina Forest Creek Hydrologic Soil Group Map unit symbol Map unit name Rating Acres in AOI Percent of AOI AeB Ailey-Appling complex,2 A 181.1 10.0% to 8 percent slopes AgC Ailey-Appling complex,8 A 17.3 1.0% to 15 percent slopes, bouldery CeB2 Cecil gravelly sandy clay B 549.1 30.3% loam,2 to 8 percent slopes,moderately eroded CeC2 Cecil gravelly sandy clay B 251.7 13.9% loam,8 to 15 percent slopes,moderately eroded ChA Chewacla silt loam,0 to B/D 67.5 3.7% 2 percent slopes, frequently flooded GeB Georgeville silt loam,2 B 7.2 0.4% to 8 percent slopes GfB2 Georgeville silty clay B 176.0 9.7% loam,2 to 8 percent slopes,moderately eroded IrA Iredell loam,0 to 3 C/D 4.6 0.3% percent slopes PaE2 Pacolet sandy clay B 68.0 3.7% loam, 15 to 40 percent slopes,moderately eroded PgC Pacolet-Gullied land B 20.5 1.1% complex,4 to 15 percent slopes ScA Secrest-Cid complex,0 C 3.8 0.2% to 3 percent slopes TbB2 Tarrus gravelly silty clay B 9.4 0.5% loam,2 to 8 percent slopes,moderately eroded TbC2 Tarrus gravelly silty clay B 319.0 17.6% loam,8 to 15 percent slopes,moderately eroded TuB Tarrus-Urban land B 122.8 6.8% complex,2 to 8 percent slopes W Water 3.6 0.2% WyB Wynott gravelly loam,2 D 11.3 0.6% to 8 percent slopes t!Sim Natural Resources Web Soil Survey 3/10/2021 Conservation Service National Cooperative Soil Survey Page 3 of 4 Hydrologic Soil Group—Union County, North Carolina Forest Creek Map unit symbol Map unit name Rating Acres in AOI Percent of AOI Totals for Area of Interest 1,812.8 100.0% Description Hydrologic soil groups are based on estimates of runoff potential. Soils are assigned to one of four groups according to the rate of water infiltration when the soils are not protected by vegetation, are thoroughly wet, and receive precipitation from long-duration storms. The soils in the United States are assigned to four groups (A, B, C, and D)and three dual classes (A/D, B/D, and C/D). The groups are defined as follows: Group A. Soils having a high infiltration rate (low runoff potential)when thoroughly wet. These consist mainly of deep, well drained to excessively drained sands or gravelly sands. These soils have a high rate of water transmission. Group B. Soils having a moderate infiltration rate when thoroughly wet. These consist chiefly of moderately deep or deep, moderately well drained or well drained soils that have moderately fine texture to moderately coarse texture. These soils have a moderate rate of water transmission. Group C. Soils having a slow infiltration rate when thoroughly wet. These consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils have a slow rate of water transmission. Group D. Soils having a very slow infiltration rate (high runoff potential)when thoroughly wet. These consist chiefly of clays that have a high shrink-swell potential, soils that have a high water table, soils that have a claypan or clay layer at or near the surface, and soils that are shallow over nearly impervious material. These soils have a very slow rate of water transmission. If a soil is assigned to a dual hydrologic group (A/D, B/D, or C/D), the first letter is for drained areas and the second is for undrained areas. Only the soils that in their natural condition are in group D are assigned to dual classes. Rating Options Aggregation Method: Dominant Condition Component Percent Cutoff:None Specified Tie-break Rule: Higher usDA Natural Resources Web Soil Survey 3/10/2021 Conservation Service National Cooperative Soil Survey Page 4 of 4 FEMA FIRM MAP: National Flood Hazard Layer FIRMette FEMA _Legend 80o45'31"W 34°54'33"N SEE FIS REPORT FOR DETAILED LEGEND AND INDEX MAP FOR FIRM PANEL LAYOUT Without Base Flood Elevation(BFE) f Zone A,V.A99 / SPECIAL FLOOD With BFE or Depth Zone AE,AD,AH,ve,AR I 3 •�_ t HAZARD AREAS Regulatory Floodway f 0.2%Annual Chance Flood Hazard,Areas �1 a of 1%annual chance flood with average 1 •' w depth less than one foot or with drainage j • • areas of less than one square mile Zone _ Future Conditions 1%Annual Chance Flood Hazard zone �I •a ` • � �" Area with Reduced Flood Risk due to • r _ �,, OTHER AREAS OF Levee.See Notes.zone '• 0 FLOOD HAZARD Area with Flood Risk due to Leveezone D � �r NO SCREEN Area of Minimal Flood Hazard zonex • . A ti• r r . Q Effective LOMRs OTHER AREAS Area of Undetermined Flood Hazard zone s ' t GENERAL ----- Channel,Culvert,or Storm Sewer Q QF ; //��� ' - • STRUCTURES IIIIIII Levee,Dike,or Floodwall - "I e zos Cross Sections with 1%Annual Chance 17•5 Water Surface Elevation ♦ AREA OF MINIMAL FLOOD HAZARD . e— — — Coastal Transect Z )( ^^^^-5I3^^^^^• Base Flood Elevation Line(BFE) s Limit of Study � Jurisdiction Boundary 4r —--- Coastal Transect Baseline OTHER _ •� 1 3 , 1 1 � Profile Baseline `! FEATURES Hydrographic Feature 1 11 ' Digital Data Available N (It' �- '� No Digital Data Available � MAP PANELS Unmapped ' f t ` • • The pin displayed on the map is an approximate �, ` �• • �• �, 1 S �` point selected by the user and does not represent t.r an authoritative property location. • r( $i it • • • , • • • � � �� This map complies with FEMA's standards for the use of • • digital flood maps if it is not void as described below. / ----- The basemap shown complies with FEMA's basemap • 4" accuracy standards •• ---- t The flood hazard information is derived directly from the • authoritative NFHL web services provided by FEMA.This map was exported on 5/4/2022 at 2:07 PM and does not �t UNION CO reflect changes or amendments subsequent to this date and time.The NFHL and effective information may change or f (AREA OT Ell I, r `� become superseded by new data over time. This map image is void if the one or more of the following map elements do not appear:basemap imagery,flood zone labels, legend,scale bar,map creation date,community identifiers, 80°44'S4"W 34°54'3"N FIRM panel number,and FIRM effective date.Map images for Feet 1:6 000 unmapped and unmodernized areas cannot be used for 0 250 500 1,000 1,500 2,000 regulatory purposes. Basemap:USGS National Map:Orthoimagery.Data refreshed October,2020 USGS MAPS: . �� � � �.\ �� � �0 � ,(/ ® - _ � � � 8a•: � � .gym ( 1 m m -10 �� ® � © a � `/ / \ �° ����, © ® © 3�`Q� ® � •�, �_� ,may,,, �\ jo Ile ��m m \ Oro 03 E Q � � � � m /•, •• ,� �� � �� ,m � �, `� � � ®gym �-\ - o 0 ��0 ,"09 t a \ \ ma • 000 .. `� ® o4 \ • 97 IN m ^J' 411 m .41 Qw 1 l 0 - CUD� 70 e B / ®, d END 000 Sediment Basin Calculations: Sediment Basin Design - Phase 1 Project: The Preserve at Forest Creek(Phase 2) Computed By: DMG Date: 2/16/2024 Location: Waxhaw,Union County,North Carolina Checked By: DMG Revised: Developer: Design Criteria: Settling Efficiency Criteria: Design Storm 10 yr Design Storm 2 yr Rational Runoff Coef£ 0.7 Rational Runoff Coeff. 0.6 Intensity 7.61 in/hr (Tc- 5 min.) Intensity 5.95 in/hr (Tc- 5 min.) Bottom Top Surface Side- 10-yr Basin Drainage Denuded Sediment Basin Area Depth Area Area slope Skimmer Orifice Dewatering Flow Number Area (Acres) Area(Acres) Volume Sq ft ft. Sq ft Required Size Diameter Time cfs Required Provided Sq ft (inches) (inches) (days) SB-1 4.65 4.65 8,370 49,368 9,638 4 15,246 10,775 3 4.0 3.10 4.45 24.77 SB-2 7.84 7.84 14,112 61,216 12,358 4 18,403 18,167 3 4.0 3.50 4.33 41.76 SB-3 3.06 3.06 5,508 24,330 3,920 4 8,404 7,091 3 2.5 2.50 3.37 16.30 SB-4 3.66 3.66 6,588 59,934 11,744 4 18,380 8,481 3 4.0 3.50 4.24 19.50 SB-5 3.77 3.77 6,786 29,488 5,396 4 9,504 8,736 31 3.0 2.60 3.78 20.08 SB-6 4.68 3.95 8,424 46,943 9,061 4 14,566 10,845 3 4.0 3.10 4.23 24.93 SB-7 1.72 1.72 3,096 47,035 9,351 4 14,319 3,986 3 4.0 3.10 4.24 9.16 SB-8 1.80 1.80 3,240 26,273 4,716 4 8,574 4,171 3 3.0 2.50 3.64 9.59 SB-9 2.77 2.77 4,986 19,481 3,250 4 6,644 6,419 3 2.5 2.20 3.48 14.76 SB-10 12.58 12.58 22,644 96,786 20,186 4 28,363 29,151 3 5.0 4.30 4.53 67.01 SB-11 1.54 1.54 2,772 12,165 1,600 4 4,641 3,569 3 2.0 1.90 2.92 8.20 SB-12 1.09 1.09 1,962 24,621 4,469 4 7,994 2,526 3 2.5 2.50 3.41 5.81 SB-13 1.22 1.22 2,196 18,081 3,095 4 6,098 2,827 3 2.5 2.10 3.55 6.50 SB-14 1.47 1.47 2,646 14,815 2,159 4 5,405 3,406 3 2.5 1.90 3.55 7.83 SB-15 1.29 1.29 2,322 13,175 2,050 4 4,690 2,989 3 2.5 1.80 3.52 6.87 SB-16 5.14 5.14 9,252 39,639 7,704 4 12,269 11,911 3 4.0 2.80 4.38 27.38 SB-17 1.55 1.55 2,790 10,872 1,602 4 3,987 3,592 3 2.0 1.80 2.91 8.26 SB-18 3.60 3.60 6,480 32,905 6,149 4 10,457 8,342 3 3.0 2.80 3.63 19.18 SB-19 3.19 3.19 5,742 25,674 4,580 4 8,410 7,392 3 3.0 2.40 3.86 16.99 SB-20 1.91 1.91 3,429 91,769 19,387 4 26,651 4,414 3 5.0 4.20 4.50 10.15 SB-21 0.80 0.80 1,440 11,732 1,606 4 4,416 1,854 3 2.0 1.80 3.14 4.26 SB-22 1.50 1.50 2,700 58,016 11,797 4 17,363 3,476 3 4.0 3.40 4.35 7.99 SB-23 2.58 2.58 4,644 23,576 4,194 4 7,747 5,978 3 2.5 2.40 3.54 13.74 SB-24 1.59 1.59 2,862 20,947 3,643 4 6,983 3,684 3 2.5 2.30 3.43 8.47 SB-251 4.921 4.921 8,856 44,244 8,6411 4 13,635 11,401 3 4.0 3.00 4.26 26.21 SB-1 Calculations: Worksheet for SBA Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 15.0 in Discharge 19.92 cfs Results Normal Depth 12.1 in Flow Area 1.1 ft2 Wetted Perimeter 2.8 ft Hydraulic Radius 4.6 in Top Width 0.99 ft Critical Depth 14.9 in Percent Full 80.8% Critical Slope 0.309 ft/ft Velocity 18.76 ft/s Velocity Head 5.47 ft Specific Energy 6.48 ft Froude Number 3.185 Maximum Discharge 21.72 cfs Discharge Full 20.19 cfs Slope Full 0.324 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 80.8% Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 12.1 in Critical Depth 14.9 in Channel Slope 0.333 ft/ft Critical Slope 0.309 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TD-1 A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.058 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 2.00 ft Discharge 4.10 cfs Results Normal Depth 3.0 in Flow Area 0.7 ftz Wetted Perimeter 3.6 ft Hydraulic Radius 2.3 in Top Width 3.50 ft Critical Depth 4.9 in Critical Slope 0.009 ft/ft Velocity 5.96 ft/s Velocity Head 0.55 ft Specific Energy 0.80 ft Froude Number 2.372 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.0 in Critical Depth 4.9 in Channel Slope 0.058 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 2 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-1 B Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.058 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 2.00 ft Discharge 2.97 cfs Results Normal Depth 2.5 in Flow Area 0.6 ft2 Wetted Perimeter 3.3 ft Hydraulic Radius 2.0 in Top Width 3.26 ft Critical Depth 4.1 in Critical Slope 0.010 ft/ft Velocity 5.40 ft/s Velocity Head 0.45 ft Specific Energy 0.66 ft Froude Number 2.313 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.5 in Critical Depth 4.1 in Channel Slope 0.058 ft/ft Critical Slope 0.010 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-1 Calculate Skimmer Size Basin Volume in Cubic Feet 49,513 Cu.Ft Skimmer Size 4.0 Inch Days to Drain* 4 Days Orifice Radius 1.6 Inch[es] Orifice Diameter 3.1 Inch[es] "In NC assume 3 days to drain SB-2 Calculations: Worksheet for S13-2A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 24.0 in Discharge 36.86 cfs Results Normal Depth 12.3 in Flow Area 1.6 ft2 Wetted Perimeter 3.2 ft Hydraulic Radius 6.1 in Top Width 2.00 ft Critical Depth 23.2 in Percent Full 51.2 % Critical Slope 0.079 ft/ft Velocity 22.74 ft/s Velocity Head 8.04 ft Specific Energy 9.06 ft Froude Number 4.454 Maximum Discharge 76.06 cfs Discharge Full 70.71 cfs Slope Full 0.090 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 51.2 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 12.3 in Critical Depth 23.2 in Channel Slope 0.333 ft/ft Critical Slope 0.079 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-2A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.068 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 2.00 ft Discharge 0.59 cfs Results Normal Depth 1.0 in Flow Area 0.2 ftz Wetted Perimeter 2.5 ft Hydraulic Radius 0.9 in Top Width 2.48 ft Critical Depth 1.6 in Critical Slope 0.012 ft/ft Velocity 3.31 ft/s Velocity Head 0.17 ft Specific Energy 0.25 ft Froude Number 2.176 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 1.0 in Critical Depth 1.6 in Channel Slope 0.068 ft/ft Critical Slope 0.012 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-213 Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.068 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 2.00 ft Discharge 36.28 cfs Results Normal Depth 8.9 in Flow Area 3.1 ft2 Wetted Perimeter 6.7 ft Hydraulic Radius 5.6 in Top Width 6.43 ft Critical Depth 15.2 in Critical Slope 0.007 ft/ft Velocity 11.65 ft/s Velocity Head 2.11 ft Specific Energy 2.85 ft Froude Number 2.953 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 8.9 in Critical Depth 15.2 in Channel Slope 0.068 ft/ft Critical Slope 0.007 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-2 Calculate Skimmer Size Basin Volume in Cubic Feet 61,216 Cu.Ft Skimmer Size 4.0 Inch Days to Drain* 4 Days Orifice Radius 1.7 Inch[es] Orifice Diameter 3.5 Inch[es] "In NC assume 3 days to drain SB-3 Calculations: Worksheet for S13-3A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 4.05 cfs Results Normal Depth 5.0 in Flow Area 0.3 ft2 Wetted Perimeter 1.4 ft Hydraulic Radius 2.6 in Top Width 0.99 ft Critical Depth 10.2 in Percent Full 41.7% Critical Slope 0.041 ft/ft Velocity 13.07 ft/s Velocity Head 2.65 ft Specific Energy 3.07 ft Froude Number 4.109 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.044 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 41.7% Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 5.0 in Critical Depth 10.2 in Channel Slope 0.333 ft/ft Critical Slope 0.041 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for S13-313 Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 4.69 cfs Results Normal Depth 5.4 in Flow Area 0.3 ft2 Wetted Perimeter 1.5 ft Hydraulic Radius 2.8 in Top Width 1.00 ft Critical Depth 10.8 in Percent Full 45.3 % Critical Slope 0.052 ft/ft Velocity 13.58 ft/s Velocity Head 2.87 ft Specific Energy 3.32 ft Froude Number 4.065 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.059 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 45.3 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 5.4 in Critical Depth 10.8 in Channel Slope 0.333 ft/ft Critical Slope 0.052 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for S13-3C Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 4.26 cfs Results Normal Depth 5.1 in Flow Area 0.3 ft2 Wetted Perimeter 1.4 ft Hydraulic Radius 2.7 in Top Width 0.99 ft Critical Depth 10.4 in Percent Full 42.9 % Critical Slope 0.045 ft/ft Velocity 13.24 ft/s Velocity Head 2.72 ft Specific Energy 3.15 ft Froude Number 4.093 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.049 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 42.9 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 5.1 in Critical Depth 10.4 in Channel Slope 0.333 ft/ft Critical Slope 0.045 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-3A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.051 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 4.05 cfs Results Normal Depth 3.5 in Flow Area 0.7 ftz Wetted Perimeter 3.3 ft Hydraulic Radius 2.5 in Top Width 3.25 ft Critical Depth 5.4 in Critical Slope 0.009 ft/ft Velocity 5.87 ft/s Velocity Head 0.53 ft Specific Energy 0.83 ft Froude Number 2.242 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.5 in Critical Depth 5.4 in Channel Slope 0.051 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-313 Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.100 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 4.69 cfs Results Normal Depth 3.2 in Flow Area 0.6 ftz Wetted Perimeter 3.2 ft Hydraulic Radius 2.3 in Top Width 3.08 ft Critical Depth 5.9 in Critical Slope 0.009 ft/ft Velocity 7.76 ft/s Velocity Head 0.94 ft Specific Energy 1.20 ft Froude Number 3.092 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.2 in Critical Depth 5.9 in Channel Slope 0.100 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-3C Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.044 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 4.26 cfs Results Normal Depth 3.7 in Flow Area 0.8 ft2 Wetted Perimeter 3.5 ft Hydraulic Radius 2.6 in Top Width 3.36 ft Critical Depth 5.6 in Critical Slope 0.009 ft/ft Velocity 5.66 ft/s Velocity Head 0.50 ft Specific Energy 0.81 ft Froude Number 2.110 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.7 in Critical Depth 5.6 in Channel Slope 0.044 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-3 Calculate Skimmer Size Basin Volume in Cubic Feet 24,330 Cu.Ft Skimmer Size 2.5 Inch Days to Drain* 4 Days Orifice Radius 1.2 Inch[es] Orifice Diameter 2.5 Inch[es] "In NC assume 3 days to drain SB-4 Calculations: Worksheet for SB-4A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 15.0 in Discharge 13.37 cfs Results Normal Depth 8.9 in Flow Area 0.8 ftz Wetted Perimeter 2.2 ft Hydraulic Radius 4.1 in Top Width 1.23 ft Critical Depth 14.7 in Percent Full 59.4% Critical Slope 0.131 ft/ft Velocity 17.59 ft/s Velocity Head 4.81 ft Specific Energy 5.55 ft Froude Number 3.939 Maximum Discharge 21.72 cfs Discharge Full 20.19 cfs Slope Full 0.146 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 59.4% Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 8.9 in Critical Depth 14.7 in Channel Slope 0.333 ft/ft Critical Slope 0.131 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-4A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.094 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 1.81 cfs Results Normal Depth 1.9 in Flow Area 0.3 ft2 Wetted Perimeter 2.5 ft Hydraulic Radius 1.5 in Top Width 2.46 ft Critical Depth 3.5 in Critical Slope 0.010 ft/ft Velocity 5.72 ft/s Velocity Head 0.51 ft Specific Energy 0.67 ft Froude Number 2.810 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 1.9 in Critical Depth 3.5 in Channel Slope 0.094 ft/ft Critical Slope 0.010 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-413 Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.094 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 11.56 cfs Results Normal Depth 5.1 in Flow Area 1.2 ftz Wetted Perimeter 4.2 ft Hydraulic Radius 3.4 in Top Width 4.05 ft Critical Depth 9.3 in Critical Slope 0.008 ft/ft Velocity 9.78 ft/s Velocity Head 1.49 ft Specific Energy 1.91 ft Froude Number 3.194 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 5.1 in Critical Depth 9.3 in Channel Slope 0.094 ft/ft Critical Slope 0.008 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-4 Calculate Skimmer Size Basin Volume in Cubic Feet 59,934 Cu.Ft Skimmer Size 4.0 Inch Days to Drain* 4 Days Orifice Radius 1.7 Inch[es] Orifice Diameter 3.5 Inch[es] "In NC assume 3 days to drain SB-5 Calculations: Worksheet for S13-5A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 15.0 in Discharge 13.80 cfs Results Normal Depth 9.1 in Flow Area 0.8 ftz Wetted Perimeter 2.2 ft Hydraulic Radius 4.2 in Top Width 1.22 ft Critical Depth 14.8 in Percent Full 60.7% Critical Slope 0.141 ft/ft Velocity 17.71 ft/s Velocity Head 4.87 ft Specific Energy 5.63 ft Froude Number 3.909 Maximum Discharge 21.72 cfs Discharge Full 20.19 cfs Slope Full 0.156 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 60.7% Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 9.1 in Critical Depth 14.8 in Channel Slope 0.333 ft/ft Critical Slope 0.141 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for S13-513 Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 3.24 cfs Results Normal Depth 4.4 in Flow Area 0.3 ft2 Wetted Perimeter 1.3 ft Hydraulic Radius 2.4 in Top Width 0.97 ft Critical Depth 9.2 in Percent Full 36.9 % Critical Slope 0.032 ft/ft Velocity 12.30 ft/s Velocity Head 2.35 ft Specific Energy 2.72 ft Froude Number 4.151 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.028 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 36.9 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 4.4 in Critical Depth 9.2 in Channel Slope 0.333 ft/ft Critical Slope 0.032 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-5A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.084 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 10.71 cfs Results Normal Depth 5.0 in Flow Area 1.2 ftz Wetted Perimeter 4.2 ft Hydraulic Radius 3.4 in Top Width 4.02 ft Critical Depth 8.9 in Critical Slope 0.008 ft/ft Velocity 9.21 ft/s Velocity Head 1.32 ft Specific Energy 1.74 ft Froude Number 3.022 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 5.0 in Critical Depth 8.9 in Channel Slope 0.084 ft/ft Critical Slope 0.008 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-513 Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.061 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 3.09 cfs Results Normal Depth 2.9 in Flow Area 0.5 ftz Wetted Perimeter 3.0 ft Hydraulic Radius 2.1 in Top Width 2.94 ft Critical Depth 4.7 in Critical Slope 0.009 ft/ft Velocity 5.78 ft/s Velocity Head 0.52 ft Specific Energy 0.76 ft Froude Number 2.389 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.9 in Critical Depth 4.7 in Channel Slope 0.061 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-5C Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.061 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 1.62 cfs Results Normal Depth 2.0 in Flow Area 0.3 ft2 Wetted Perimeter 2.6 ft Hydraulic Radius 1.6 in Top Width 2.52 ft Critical Depth 3.3 in Critical Slope 0.010 ft/ft Velocity 4.76 ft/s Velocity Head 0.35 ft Specific Energy 0.52 ft Froude Number 2.281 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.0 in Critical Depth 3.3 in Channel Slope 0.061 ft/ft Critical Slope 0.010 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TD-50 Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.061 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 1.62 cfs Results Normal Depth 2.0 in Flow Area 0.3 ft2 Wetted Perimeter 2.6 ft Hydraulic Radius 1.6 in Top Width 2.52 ft Critical Depth 3.3 in Critical Slope 0.010 ft/ft Velocity 4.76 ft/s Velocity Head 0.35 ft Specific Energy 0.52 ft Froude Number 2.281 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.0 in Critical Depth 3.3 in Channel Slope 0.061 ft/ft Critical Slope 0.010 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-5 Calculate Skimmer Size Basin Volume in Cubic Feet 29,488 Cu.Ft Skimmer Size 3.0 Inch Days to Drain* 4 Days Orifice Radius 1.3 Inch[es] Orifice Diameter 2.6 Inch[es] "In NC assume 3 days to drain SB-6 Calculations: Worksheet for S13-6A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 4.95 cfs Results Normal Depth 5.6 in Flow Area 0.4 ftz Wetted Perimeter 1.5 ft Hydraulic Radius 2.9 in Top Width 1.00 ft Critical Depth 11.0 in Percent Full 46.7% Critical Slope 0.057 ft/ft Velocity 13.76 ft/s Velocity Head 2.94 ft Specific Energy 3.41 ft Froude Number 4.042 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.066 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 46.7% Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 5.6 in Critical Depth 11.0 in Channel Slope 0.333 ft/ft Critical Slope 0.057 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for S13-613 Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 15.0 in Discharge 14.49 cfs Results Normal Depth 9.4 in Flow Area 0.8 ftz Wetted Perimeter 2.3 ft Hydraulic Radius 4.3 in Top Width 1.21 ft Critical Depth 14.8 in Percent Full 62.7% Critical Slope 0.156 ft/ft Velocity 17.89 ft/s Velocity Head 4.97 ft Specific Energy 5.76 ft Froude Number 3.853 Maximum Discharge 21.72 cfs Discharge Full 20.19 cfs Slope Full 0.172 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 62.7% Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 9.4 in Critical Depth 14.8 in Channel Slope 0.333 ft/ft Critical Slope 0.156 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for SB-6C Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 2.88 cfs Results Normal Depth 4.2 in Flow Area 0.2 ftz Wetted Perimeter 1.3 ft Hydraulic Radius 2.3 in Top Width 0.95 ft Critical Depth 8.7 in Percent Full 34.7% Critical Slope 0.029 ft/ft Velocity 11.90 ft/s Velocity Head 2.20 ft Specific Energy 2.55 ft Froude Number 4.160 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.022 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 34.7% Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 4.2 in Critical Depth 8.7 in Channel Slope 0.333 ft/ft Critical Slope 0.029 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-6A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.029 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 4.95 cfs Results Normal Depth 4.5 in Flow Area 1.0 ft2 Wetted Perimeter 3.9 ft Hydraulic Radius 3.0 in Top Width 3.73 ft Critical Depth 6.0 in Critical Slope 0.009 ft/ft Velocity 5.09 ft/s Velocity Head 0.40 ft Specific Energy 0.77 ft Froude Number 1.757 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 4.5 in Critical Depth 6.0 in Channel Slope 0.029 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-613 Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.041 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 0.54 cfs Results Normal Depth 1.2 in Flow Area 0.2 ftz Wetted Perimeter 2.1 ft Hydraulic Radius 1.0 in Top Width 2.11 ft Critical Depth 1.7 in Critical Slope 0.012 ft/ft Velocity 2.93 ft/s Velocity Head 0.13 ft Specific Energy 0.24 ft Froude Number 1.747 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 1.2 in Critical Depth 1.7 in Channel Slope 0.041 ft/ft Critical Slope 0.012 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-6C Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.041 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 2.86 cfs Results Normal Depth 3.1 in Flow Area 0.6 ft2 Wetted Perimeter 3.1 ft Hydraulic Radius 2.2 in Top Width 3.04 ft Critical Depth 4.5 in Critical Slope 0.009 ft/ft Velocity 4.92 ft/s Velocity Head 0.38 ft Specific Energy 0.63 ft Froude Number 1.982 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.1 in Critical Depth 4.5 in Channel Slope 0.041 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TD-60 Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.041 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 2.86 cfs Results Normal Depth 3.1 in Flow Area 0.6 ft2 Wetted Perimeter 3.1 ft Hydraulic Radius 2.2 in Top Width 3.04 ft Critical Depth 4.5 in Critical Slope 0.009 ft/ft Velocity 4.92 ft/s Velocity Head 0.38 ft Specific Energy 0.63 ft Froude Number 1.982 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.1 in Critical Depth 4.5 in Channel Slope 0.041 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-6 Calculate Skimmer Size Basin Volume in Cubic Feet 46,943 Cu.Ft Skimmer Size 4.0 Inch Days to Drain* 4 Days Orifice Radius 1.5 Inch[es] Orifice Diameter 3.1 Inch[es] "In NC assume 3 days to drain SB-7 Calculations: Worksheet for S13-7A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 8.74 cfs Results Normal Depth 8.0 in Flow Area 0.6 ftz Wetted Perimeter 1.9 ft Hydraulic Radius 3.5 in Top Width 0.94 ft Critical Depth 11.9 in Percent Full 66.7% Critical Slope 0.189 ft/ft Velocity 15.69 ft/s Velocity Head 3.83 ft Specific Energy 4.49 ft Froude Number 3.598 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.205 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 66.7% Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 8.0 in Critical Depth 11.9 in Channel Slope 0.333 ft/ft Critical Slope 0.189 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-7A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.075 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 5.01 cfs Results Normal Depth 3.5 in Flow Area 0.7 ftz Wetted Perimeter 3.4 ft Hydraulic Radius 2.5 in Top Width 3.27 ft Critical Depth 6.1 in Critical Slope 0.009 ft/ft Velocity 7.14 ft/s Velocity Head 0.79 ft Specific Energy 1.09 ft Froude Number 2.717 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.5 in Critical Depth 6.1 in Channel Slope 0.075 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-713 Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.075 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 3.73 cfs Results Normal Depth 3.0 in Flow Area 0.6 ft2 Wetted Perimeter 3.1 ft Hydraulic Radius 2.2 in Top Width 3.01 ft Critical Depth 5.2 in Critical Slope 0.009 ft/ft Velocity 6.57 ft/s Velocity Head 0.67 ft Specific Energy 0.92 ft Froude Number 2.666 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.0 in Critical Depth 5.2 in Channel Slope 0.075 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-7 Calculate Skimmer Size Basin Volume in Cubic Feet 47,035 Cu.Ft Skimmer Size 4.0 Inch Days to Drain* 4 Days Orifice Radius 1.5 Inch[es] Orifice Diameter 3.1 Inch[es] "In NC assume 3 days to drain SB-8 Calculations: Worksheet for S13-8A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 6.23 cfs Results Normal Depth 6.4 in Flow Area 0.4 ftz Wetted Perimeter 1.6 ft Hydraulic Radius 3.1 in Top Width 1.00 ft Critical Depth 11.5 in Percent Full 53.5 % Critical Slope 0.091 ft/ft Velocity 14.58 ft/s Velocity Head 3.30 ft Specific Energy 3.84 ft Froude Number 3.926 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.104 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 53.5 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 6.4 in Critical Depth 11.5 in Channel Slope 0.333 ft/ft Critical Slope 0.091 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for S13-813 Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 1.33 cfs Results Normal Depth 2.8 in Flow Area 0.1 ftz Wetted Perimeter 1.0 ft Hydraulic Radius 1.7 in Top Width 0.85 ft Critical Depth 5.9 in Percent Full 23.3 % Critical Slope 0.021 ft/ft Velocity 9.55 ft/s Velocity Head 1.42 ft Specific Energy 1.65 ft Froude Number 4.152 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.005 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 23.3 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.8 in Critical Depth 5.9 in Channel Slope 0.333 ft/ft Critical Slope 0.021 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-8A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.022 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 6.23 cfs Results Normal Depth 5.4 in Flow Area 1.3 ftz Wetted Perimeter 4.4 ft Hydraulic Radius 3.5 in Top Width 4.21 ft Critical Depth 6.8 in Critical Slope 0.009 ft/ft Velocity 4.84 ft/s Velocity Head 0.36 ft Specific Energy 0.81 ft Froude Number 1.542 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 5.4 in Critical Depth 6.8 in Channel Slope 0.022 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-813 Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.022 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 1.33 cfs Results Normal Depth 2.4 in Flow Area 0.4 ftz Wetted Perimeter 2.8 ft Hydraulic Radius 1.8 in Top Width 2.71 ft Critical Depth 2.9 in Critical Slope 0.011 ft/ft Velocity 3.13 ft/s Velocity Head 0.15 ft Specific Energy 0.35 ft Froude Number 1.391 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.4 in Critical Depth 2.9 in Channel Slope 0.022 ft/ft Critical Slope 0.011 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-8 Calculate Skimmer Size Basin Volume in Cubic Feet 26,273 Cu.Ft Skimmer Size 3.0 Inch Days to Drain* 4 Days Orifice Radius 1.2 Inch[es] Orifice Diameter 2.5 Inch[es] "In NC assume 3 days to drain SB-9 Calculations: Worksheet for S13-9A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 2.77 cfs Results Normal Depth 4.1 in Flow Area 0.2 ftz Wetted Perimeter 1.2 ft Hydraulic Radius 2.3 in Top Width 0.95 ft Critical Depth 8.6 in Percent Full 34.0 % Critical Slope 0.028 ft/ft Velocity 11.76 ft/s Velocity Head 2.15 ft Specific Energy 2.49 ft Froude Number 4.161 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.021 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 34.0 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 4.1 in Critical Depth 8.6 in Channel Slope 0.333 ft/ft Critical Slope 0.028 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for S13-913 Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 9.72 cfs Results Normal Depth 8.7 in Flow Area 0.6 ft2 Wetted Perimeter 2.0 ft Hydraulic Radius 3.6 in Top Width 0.89 ft Critical Depth 11.9 in Percent Full 72.3 % Critical Slope 0.237 ft/ft Velocity 15.98 ft/s Velocity Head 3.97 ft Specific Energy 4.69 ft Froude Number 3.417 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.254 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 72.3 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 8.7 in Critical Depth 11.9 in Channel Slope 0.333 ft/ft Critical Slope 0.237 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-9A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.066 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 2.77 cfs Results Normal Depth 2.7 in Flow Area 0.5 ftz Wetted Perimeter 2.9 ft Hydraulic Radius 2.0 in Top Width 2.83 ft Critical Depth 4.4 in Critical Slope 0.010 ft/ft Velocity 5.75 ft/s Velocity Head 0.51 ft Specific Energy 0.74 ft Froude Number 2.461 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.7 in Critical Depth 4.4 in Channel Slope 0.066 ft/ft Critical Slope 0.010 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-913 Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.034 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 2.00 cfs Results Normal Depth 2.7 in Flow Area 0.5 ftz Wetted Perimeter 2.9 ft Hydraulic Radius 2.0 in Top Width 2.84 ft Critical Depth 3.7 in Critical Slope 0.010 ft/ft Velocity 4.13 ft/s Velocity Head 0.26 ft Specific Energy 0.49 ft Froude Number 1.761 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.7 in Critical Depth 3.7 in Channel Slope 0.034 ft/ft Critical Slope 0.010 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-9C Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.034 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 1.45 cfs Results Normal Depth 2.3 in Flow Area 0.4 ft2 Wetted Perimeter 2.7 ft Hydraulic Radius 1.7 in Top Width 2.63 ft Critical Depth 3.1 in Critical Slope 0.010 ft/ft Velocity 3.75 ft/s Velocity Head 0.22 ft Specific Energy 0.41 ft Froude Number 1.722 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.3 in Critical Depth 3.1 in Channel Slope 0.034 ft/ft Critical Slope 0.010 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-9 Calculate Skimmer Size Basin Volume in Cubic Feet 19,481 Cu.Ft Skimmer Size 2.5 Inch Days to Drain* 4 Days Orifice Radius 1.1 Inch[es] Orifice Diameter 2.2 Inch[es] "In NC assume 3 days to drain SB-10 Calculations: Worksheet for S13-10A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 24.0 in Discharge 59.88 cfs Results Normal Depth 17.0 in Flow Area 2.4 ftz Wetted Perimeter 4.0 ft Hydraulic Radius 7.1 in Top Width 1.82 ft Critical Depth 23.9 in Percent Full 70.6% Critical Slope 0.225 ft/ft Velocity 25.25 ft/s Velocity Head 9.90 ft Specific Energy 11.32 ft Froude Number 3.901 Maximum Discharge 76.06 cfs Discharge Full 70.71 cfs Slope Full 0.239 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 70.6% Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 17.0 in Critical Depth 23.9 in Channel Slope 0.333 ft/ft Critical Slope 0.225 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TD-10A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.046 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 3.00 ft Discharge 59.88 cfs Results Normal Depth 11.0 in Flow Area 5.3 ftz Wetted Perimeter 8.8 ft Hydraulic Radius 7.2 in Top Width 8.51 ft Critical Depth 17.7 in Critical Slope 0.006 ft/ft Velocity 11.32 ft/s Velocity Head 1.99 ft Specific Energy 2.91 ft Froude Number 2.533 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 11.0 in Critical Depth 17.7 in Channel Slope 0.046 ft/ft Critical Slope 0.006 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-10 Calculate Skimmer Size Basin Volume in Cubic Feet 96,786 Cu.Ft Skimmer Size 5.0 Inch Days to Drain* 4 Days Orifice Radius 2.2 Inch[es] Orifice Diameter 4.3 Inch[es] In NC assume 3 days to drain SB-11 Calculations: Worksheet for S13-11A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 2.56 cfs Results Normal Depth 3.9 in Flow Area 0.2 ftz Wetted Perimeter 1.2 ft Hydraulic Radius 2.2 in Top Width 0.94 ft Critical Depth 8.2 in Percent Full 32.6% Critical Slope 0.027 ft/ft Velocity 11.52 ft/s Velocity Head 2.06 ft Specific Energy 2.39 ft Froude Number 4.171 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.018 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 32.6% Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.9 in Critical Depth 8.2 in Channel Slope 0.333 ft/ft Critical Slope 0.027 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for S13-11 B Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 4.65 cfs Results Normal Depth 5.4 in Flow Area 0.3 ft2 Wetted Perimeter 1.5 ft Hydraulic Radius 2.8 in Top Width 1.00 ft Critical Depth 10.8 in Percent Full 45.1 % Critical Slope 0.051 ft/ft Velocity 13.53 ft/s Velocity Head 2.85 ft Specific Energy 3.30 ft Froude Number 4.059 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.058 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 45.1 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 5.4 in Critical Depth 10.8 in Channel Slope 0.333 ft/ft Critical Slope 0.051 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TD-11A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.077 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 1.86 cfs Results Normal Depth 2.1 in Flow Area 0.3 ft2 Wetted Perimeter 2.6 ft Hydraulic Radius 1.6 in Top Width 2.53 ft Critical Depth 3.6 in Critical Slope 0.010 ft/ft Velocity 5.38 ft/s Velocity Head 0.45 ft Specific Energy 0.62 ft Froude Number 2.569 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.1 in Critical Depth 3.6 in Channel Slope 0.077 ft/ft Critical Slope 0.010 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TD-11 B Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.032 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 0.69 cfs Results Normal Depth 1.5 in Flow Area 0.2 ftz Wetted Perimeter 2.3 ft Hydraulic Radius 1.2 in Top Width 2.26 ft Critical Depth 2.0 in Critical Slope 0.012 ft/ft Velocity 2.91 ft/s Velocity Head 0.13 ft Specific Energy 0.26 ft Froude Number 1.582 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 1.5 in Critical Depth 2.0 in Channel Slope 0.032 ft/ft Critical Slope 0.012 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TD-11 C Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.032 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 4.63 cfs Results Normal Depth 4.2 in Flow Area 0.9 ftz Wetted Perimeter 3.7 ft Hydraulic Radius 2.9 in Top Width 3.61 ft Critical Depth 5.8 in Critical Slope 0.009 ft/ft Velocity 5.14 ft/s Velocity Head 0.41 ft Specific Energy 0.76 ft Froude Number 1.814 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 4.2 in Critical Depth 5.8 in Channel Slope 0.032 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-11 Calculate Skimmer Size Basin Volume in Cubic Feet 12,165 Cu.Ft Skimmer Size 2.0 Inch Days to Drain* 4 Days Orifice Radius 0.9 Inch[es] Orifice Diameter 1.9 Inch[es] "In NC assume 3 days to drain SB-12 Calculations: Worksheet for SB-12A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 5.75 cfs Results Normal Depth 6.1 in Flow Area 0.4 ftz Wetted Perimeter 1.6 ft Hydraulic Radius 3.0 in Top Width 1.00 ft Critical Depth 11.4 in Percent Full 51.0 % Critical Slope 0.077 ft/ft Velocity 14.30 ft/s Velocity Head 3.18 ft Specific Energy 3.69 ft Froude Number 3.973 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.089 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 51.0 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 6.1 in Critical Depth 11.4 in Channel Slope 0.333 ft/ft Critical Slope 0.077 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-12A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.024 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 5.75 cfs Results Normal Depth 5.1 in Flow Area 1.2 ftz Wetted Perimeter 4.2 ft Hydraulic Radius 3.4 in Top Width 4.05 ft Critical Depth 6.5 in Critical Slope 0.009 ft/ft Velocity 4.89 ft/s Velocity Head 0.37 ft Specific Energy 0.80 ft Froude Number 1.598 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 5.1 in Critical Depth 6.5 in Channel Slope 0.024 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-12 Calculate Skimmer Size Basin Volume in Cubic Feet 24,621 Cu.Ft Skimmer Size 2.5 Inch Days to Drain* 4 Days Orifice Radius 1.2 Inch[es] Orifice Diameter 2.5 Inch[es] "In NC assume 3 days to drain SB-13 Calculations: Worksheet for SB-13A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 2.40 cfs Results Normal Depth 3.8 in Flow Area 0.2 ftz Wetted Perimeter 1.2 ft Hydraulic Radius 2.1 in Top Width 0.93 ft Critical Depth 8.0 in Percent Full 31.5 % Critical Slope 0.026 ft/ft Velocity 11.31 ft/s Velocity Head 1.99 ft Specific Energy 2.30 ft Froude Number 4.171 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.015 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 31.5 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.8 in Critical Depth 8.0 in Channel Slope 0.333 ft/ft Critical Slope 0.026 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for SB-13B Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 3.20 cfs Results Normal Depth 4.4 in Flow Area 0.3 ft2 Wetted Perimeter 1.3 ft Hydraulic Radius 2.4 in Top Width 0.96 ft Critical Depth 9.2 in Percent Full 36.7% Critical Slope 0.032 ft/ft Velocity 12.24 ft/s Velocity Head 2.33 ft Specific Energy 2.70 ft Froude Number 4.144 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.027 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 36.7% Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 4.4 in Critical Depth 9.2 in Channel Slope 0.333 ft/ft Critical Slope 0.032 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-13A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.021 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 1.97 cfs Results Normal Depth 3.0 in Flow Area 0.6 ft2 Wetted Perimeter 3.1 ft Hydraulic Radius 2.2 in Top Width 3.01 ft Critical Depth 3.7 in Critical Slope 0.010 ft/ft Velocity 3.47 ft/s Velocity Head 0.19 ft Specific Energy 0.44 ft Froude Number 1.407 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.0 in Critical Depth 3.7 in Channel Slope 0.021 ft/ft Critical Slope 0.010 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TD-1313 Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.016 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 0.43 cfs Results Normal Depth 1.4 in Flow Area 0.2 ftz Wetted Perimeter 2.2 ft Hydraulic Radius 1.2 in Top Width 2.21 ft Critical Depth 1.5 in Critical Slope 0.013 ft/ft Velocity 1.97 ft/s Velocity Head 0.06 ft Specific Energy 0.18 ft Froude Number 1.103 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 1.4 in Critical Depth 1.5 in Channel Slope 0.016 ft/ft Critical Slope 0.013 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TD-13C Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.021 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 0.21 cfs Results Normal Depth 0.9 in Flow Area 0.1 ft2 Wetted Perimeter 2.0 ft Hydraulic Radius 0.8 in Top Width 1.93 ft Critical Depth 1.0 in Critical Slope 0.014 ft/ft Velocity 1.70 ft/s Velocity Head 0.04 ft Specific Energy 0.12 ft Froude Number 1.182 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 0.9 in Critical Depth 1.0 in Channel Slope 0.021 ft/ft Critical Slope 0.014 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TD-13D Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.021 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 2.98 cfs Results Normal Depth 3.8 in Flow Area 0.8 ft2 Wetted Perimeter 3.5 ft Hydraulic Radius 2.6 in Top Width 3.38 ft Critical Depth 4.6 in Critical Slope 0.009 ft/ft Velocity 3.90 ft/s Velocity Head 0.24 ft Specific Energy 0.55 ft Froude Number 1.446 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.8 in Critical Depth 4.6 in Channel Slope 0.021 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-13 Calculate Skimmer Size Basin Volume in Cubic Feet 18,081 Cu.Ft Skimmer Size 2.5 Inch Days to Drain* 4 Days Orifice Radius 1.1 Inch[es] Orifice Diameter 2.1 Inch[es] "In NC assume 3 days to drain SB-14 Calculations: Worksheet for SB-14A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 7.83 cfs Results Normal Depth 7.4 in Flow Area 0.5 ftz Wetted Perimeter 1.8 ft Hydraulic Radius 3.4 in Top Width 0.97 ft Critical Depth 11.8 in Percent Full 61.8% Critical Slope 0.149 ft/ft Velocity 15.35 ft/s Velocity Head 3.66 ft Specific Energy 4.28 ft Froude Number 3.736 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.165 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 61.8% Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 7.4 in Critical Depth 11.8 in Channel Slope 0.333 ft/ft Critical Slope 0.149 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-14A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.028 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 3.68 cfs Results Normal Depth 3.9 in Flow Area 0.8 ft2 Wetted Perimeter 3.6 ft Hydraulic Radius 2.7 in Top Width 3.45 ft Critical Depth 5.2 in Critical Slope 0.009 ft/ft Velocity 4.58 ft/s Velocity Head 0.33 ft Specific Energy 0.65 ft Froude Number 1.673 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.9 in Critical Depth 5.2 in Channel Slope 0.028 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-14B Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.028 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 4.16 cfs Results Normal Depth 4.2 in Flow Area 0.9 ftz Wetted Perimeter 3.7 ft Hydraulic Radius 2.9 in Top Width 3.58 ft Critical Depth 5.5 in Critical Slope 0.009 ft/ft Velocity 4.74 ft/s Velocity Head 0.35 ft Specific Energy 0.69 ft Froude Number 1.685 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 4.2 in Critical Depth 5.5 in Channel Slope 0.028 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-14 Calculate Skimmer Size Basin Volume in Cubic Feet 14,815 Cu.Ft Skimmer Size 2.5 Inch Days to Drain* 4 Days Orifice Radius 1.0 Inch[es] Orifice Diameter 1.9 Inch[es] "In NC assume 3 days to drain SB-15 Calculations: Worksheet for SB-15A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 4.63 cfs Results Normal Depth 5.4 in Flow Area 0.3 ft2 Wetted Perimeter 1.5 ft Hydraulic Radius 2.8 in Top Width 0.99 ft Critical Depth 10.7 in Percent Full 45.0 % Critical Slope 0.051 ft/ft Velocity 13.52 ft/s Velocity Head 2.84 ft Specific Energy 3.29 ft Froude Number 4.061 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.058 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 45.0 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 5.4 in Critical Depth 10.7 in Channel Slope 0.333 ft/ft Critical Slope 0.051 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-15A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.051 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 4.63 cfs Results Normal Depth 3.7 in Flow Area 0.8 ft2 Wetted Perimeter 3.5 ft Hydraulic Radius 2.6 in Top Width 3.37 ft Critical Depth 5.8 in Critical Slope 0.009 ft/ft Velocity 6.08 ft/s Velocity Head 0.57 ft Specific Energy 0.89 ft Froude Number 2.256 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.7 in Critical Depth 5.8 in Channel Slope 0.051 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-15 Calculate Skimmer Size Basin Volume in Cubic Feet 13,175 Cu.Ft Skimmer Size 2.5 Inch Days to Drain* 4 Days Orifice Radius 0.9 Inch[es] Orifice Diameter 1.8 Inch[es] "In NC assume 3 days to drain SB-16 Calculations: Worksheet for SB-16A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 3.04 cfs Results Normal Depth 4.3 in Flow Area 0.3 ft2 Wetted Perimeter 1.3 ft Hydraulic Radius 2.4 in Top Width 0.96 ft Critical Depth 9.0 in Percent Full 35.7% Critical Slope 0.030 ft/ft Velocity 12.08 ft/s Velocity Head 2.27 ft Specific Energy 2.62 ft Froude Number 4.154 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.025 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 35.7% Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 4.3 in Critical Depth 9.0 in Channel Slope 0.333 ft/ft Critical Slope 0.030 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for SB-16B Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 15.0 in Discharge 21.57 cfs Results Normal Depth 13.6 in Flow Area 1.2 ft2 Wetted Perimeter 3.1 ft Hydraulic Radius 4.5 in Top Width 0.73 ft Critical Depth 15.0 in Percent Full 90.5 % Critical Slope 0.364 ft/ft Velocity 18.46 ft/s Velocity Head 5.30 ft Specific Energy 6.43 ft Froude Number 2.575 Maximum Discharge 21.72 cfs Discharge Full 20.19 cfs Slope Full 0.380 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 90.5 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 13.6 in Critical Depth 15.0 in Channel Slope 0.333 ft/ft Critical Slope 0.364 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TD-16A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.049 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 0.57 cfs Results Normal Depth 1.2 in Flow Area 0.2 ftz Wetted Perimeter 2.1 ft Hydraulic Radius 1.0 in Top Width 2.10 ft Critical Depth 1.8 in Critical Slope 0.012 ft/ft Velocity 3.15 ft/s Velocity Head 0.15 ft Specific Energy 0.25 ft Froude Number 1.892 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 1.2 in Critical Depth 1.8 in Channel Slope 0.049 ft/ft Critical Slope 0.012 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TD-1613 Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.102 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 19.39 cfs Results Normal Depth 6.5 in Flow Area 1.7 ft2 Wetted Perimeter 4.9 ft Hydraulic Radius 4.1 in Top Width 4.73 ft Critical Depth 11.9 in Critical Slope 0.007 ft/ft Velocity 11.58 ft/s Velocity Head 2.08 ft Specific Energy 2.62 ft Froude Number 3.428 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 6.5 in Critical Depth 11.9 in Channel Slope 0.102 ft/ft Critical Slope 0.007 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TD-16C Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.102 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 2.18 cfs Results Normal Depth 2.1 in Flow Area 0.4 ft2 Wetted Perimeter 2.6 ft Hydraulic Radius 1.6 in Top Width 2.54 ft Critical Depth 3.9 in Critical Slope 0.010 ft/ft Velocity 6.23 ft/s Velocity Head 0.60 ft Specific Energy 0.78 ft Froude Number 2.957 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.1 in Critical Depth 3.9 in Channel Slope 0.102 ft/ft Critical Slope 0.010 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-16 Calculate Skimmer Size Basin Volume in Cubic Feet 39,639 Cu.Ft Skimmer Size 4.0 Inch Days to Drain* 4 Days Orifice Radius 1.4 Inch[es] Orifice Diameter 2.8 Inch[es] "In NC assume 3 days to drain SB-17 Calculations: Worksheet for SB-17A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 6.98 cfs Results Normal Depth 6.9 in Flow Area 0.5 ftz Wetted Perimeter 1.7 ft Hydraulic Radius 3.3 in Top Width 0.99 ft Critical Depth 11.7 in Percent Full 57.4% Critical Slope 0.116 ft/ft Velocity 14.97 ft/s Velocity Head 3.48 ft Specific Energy 4.06 ft Froude Number 3.844 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.131 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 57.4% Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 6.9 in Critical Depth 11.7 in Channel Slope 0.333 ft/ft Critical Slope 0.116 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TD-17A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.053 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 5.08 cfs Results Normal Depth 3.9 in Flow Area 0.8 ft2 Wetted Perimeter 3.6 ft Hydraulic Radius 2.7 in Top Width 3.45 ft Critical Depth 6.1 in Critical Slope 0.009 ft/ft Velocity 6.34 ft/s Velocity Head 0.62 ft Specific Energy 0.95 ft Froude Number 2.316 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.9 in Critical Depth 6.1 in Channel Slope 0.053 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-17 Calculate Skimmer Size Basin Volume in Cubic Feet 10,872 Cu.Ft Skimmer Size 2.0 Inch Days to Drain* 4 Days Orifice Radius 0.9 Inch[es] Orifice Diameter 1.8 Inch[es] "In NC assume 3 days to drain SB-18 Calculations: Worksheet for SB-18A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 6.0 in Discharge 0.37 cfs Results Normal Depth 1.9 in Flow Area 0.1 ft2 Wetted Perimeter 0.6 ft Hydraulic Radius 1.1 in Top Width 0.46 ft Critical Depth 3.7 in Percent Full 31.2 % Critical Slope 0.030 ft/ft Velocity 7.07 ft/s Velocity Head 0.78 ft Specific Energy 0.93 ft Froude Number 3.708 Maximum Discharge 1.89 cfs Discharge Full 1.75 cfs Slope Full 0.015 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 31.2 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 1.9 in Critical Depth 3.7 in Channel Slope 0.333 ft/ft Critical Slope 0.030 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for SB-18B Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 15.0 in Discharge 15.29 cfs Results Normal Depth 9.8 in Flow Area 0.8 ftz Wetted Perimeter 2.3 ft Hydraulic Radius 4.3 in Top Width 1.19 ft Critical Depth 14.8 in Percent Full 65.1 % Critical Slope 0.176 ft/ft Velocity 18.09 ft/s Velocity Head 5.08 ft Specific Energy 5.90 ft Froude Number 3.787 Maximum Discharge 21.72 cfs Discharge Full 20.19 cfs Slope Full 0.191 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 65.1 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 9.8 in Critical Depth 14.8 in Channel Slope 0.333 ft/ft Critical Slope 0.176 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TD-18A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.092 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 0.37 cfs Results Normal Depth 0.8 in Flow Area 0.1 ft2 Wetted Perimeter 1.9 ft Hydraulic Radius 0.7 in Top Width 1.89 ft Critical Depth 1.4 in Critical Slope 0.013 ft/ft Velocity 3.36 ft/s Velocity Head 0.18 ft Specific Energy 0.24 ft Froude Number 2.450 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 0.8 in Critical Depth 1.4 in Channel Slope 0.092 ft/ft Critical Slope 0.013 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TD-1813 Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.097 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 15.29 cfs Results Normal Depth 5.8 in Flow Area 1.4 ftz Wetted Perimeter 4.6 ft Hydraulic Radius 3.8 in Top Width 4.40 ft Critical Depth 10.6 in Critical Slope 0.008 ft/ft Velocity 10.70 ft/s Velocity Head 1.78 ft Specific Energy 2.26 ft Froude Number 3.311 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 5.8 in Critical Depth 10.6 in Channel Slope 0.097 ft/ft Critical Slope 0.008 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-18 Calculate Skimmer Size Basin Volume in Cubic Feet 32,905 Cu.Ft Skimmer Size 3.0 Inch Days to Drain* 4 Days Orifice Radius 1.4 Inch[es] Orifice Diameter 2.8 Inch[es] "In NC assume 3 days to drain SB-19 Calculations: Worksheet for SB-19A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 15.0 in Discharge 15.13 cfs Results Normal Depth 9.7 in Flow Area 0.8 ft2 Wetted Perimeter 2.3 ft Hydraulic Radius 4.3 in Top Width 1.20 ft Critical Depth 14.8 in Percent Full 64.6% Critical Slope 0.172 ft/ft Velocity 18.05 ft/s Velocity Head 5.06 ft Specific Energy 5.87 ft Froude Number 3.800 Maximum Discharge 21.72 cfs Discharge Full 20.19 cfs Slope Full 0.187 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 64.6% Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 9.7 in Critical Depth 14.8 in Channel Slope 0.333 ft/ft Critical Slope 0.172 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-19A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.069 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 1.92 cfs Results Normal Depth 2.2 in Flow Area 0.4 ftz Wetted Perimeter 2.6 ft Hydraulic Radius 1.7 in Top Width 2.58 ft Critical Depth 3.6 in Critical Slope 0.010 ft/ft Velocity 5.24 ft/s Velocity Head 0.43 ft Specific Energy 0.61 ft Froude Number 2.452 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.2 in Critical Depth 3.6 in Channel Slope 0.069 ft/ft Critical Slope 0.010 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-19B Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.069 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 12.41 cfs Results Normal Depth 5.7 in Flow Area 1.4 ftz Wetted Perimeter 4.5 ft Hydraulic Radius 3.7 in Top Width 4.35 ft Critical Depth 9.6 in Critical Slope 0.008 ft/ft Velocity 8.92 ft/s Velocity Head 1.24 ft Specific Energy 1.71 ft Froude Number 2.782 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 5.7 in Critical Depth 9.6 in Channel Slope 0.069 ft/ft Critical Slope 0.008 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-19C Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.069 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 0.80 cfs Results Normal Depth 1.3 in Flow Area 0.2 ft2 Wetted Perimeter 2.2 ft Hydraulic Radius 1.1 in Top Width 2.16 ft Critical Depth 2.2 in Critical Slope 0.011 ft/ft Velocity 3.97 ft/s Velocity Head 0.25 ft Specific Energy 0.36 ft Froude Number 2.293 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 1.3 in Critical Depth 2.2 in Channel Slope 0.069 ft/ft Critical Slope 0.011 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-19 Calculate Skimmer Size Basin Volume in Cubic Feet 25,674 Cu.Ft Skimmer Size 3.0 Inch Days to Drain* 4 Days Orifice Radius 1.2 Inch[es] Orifice Diameter 2.4 Inch[es] "In NC assume 3 days to drain SB-20 Calculations: Worksheet for SB-20A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 0.57 cfs Results Normal Depth 1.8 in Flow Area 0.1 ftz Wetted Perimeter 0.8 ft Hydraulic Radius 1.1 in Top Width 0.72 ft Critical Depth 3.8 in Percent Full 15.4% Critical Slope 0.019 ft/ft Velocity 7.44 ft/s Velocity Head 0.86 ft Specific Energy 1.01 ft Froude Number 4.025 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.001 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 15.4% Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 1.8 in Critical Depth 3.8 in Channel Slope 0.333 ft/ft Critical Slope 0.019 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-20A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.014 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 3.05 cfs Results Normal Depth 4.2 in Flow Area 0.9 ftz Wetted Perimeter 3.7 ft Hydraulic Radius 2.9 in Top Width 3.61 ft Critical Depth 4.7 in Critical Slope 0.009 ft/ft Velocity 3.40 ft/s Velocity Head 0.18 ft Specific Energy 0.53 ft Froude Number 1.204 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 4.2 in Critical Depth 4.7 in Channel Slope 0.014 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-20 Calculate Skimmer Size Basin Volume in Cubic Feet 91,769 Cu.Ft Skimmer Size 5.0 Inch Days to Drain* 4 Days Orifice Radius 2.1 Inch[es] Orifice Diameter 4.2 Inch[es] "In NC assume 3 days to drain SB-21 Calculations: Worksheet for SB-21A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 2.18 cfs Results Normal Depth 3.6 in Flow Area 0.2 ft2 Wetted Perimeter 1.2 ft Hydraulic Radius 2.1 in Top Width 0.92 ft Critical Depth 7.6 in Percent Full 30.0 % Critical Slope 0.024 ft/ft Velocity 11.00 ft/s Velocity Head 1.88 ft Specific Energy 2.18 ft Froude Number 4.172 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.013 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 30.0 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.6 in Critical Depth 7.6 in Channel Slope 0.333 ft/ft Critical Slope 0.024 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for SB-21 B Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 1.28 cfs Results Normal Depth 2.7 in Flow Area 0.1 ftz Wetted Perimeter 1.0 ft Hydraulic Radius 1.6 in Top Width 0.84 ft Critical Depth 5.7 in Percent Full 22.9 % Critical Slope 0.021 ft/ft Velocity 9.44 ft/s Velocity Head 1.39 ft Specific Energy 1.61 ft Froude Number 4.144 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.004 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 22.9 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.7 in Critical Depth 5.7 in Channel Slope 0.333 ft/ft Critical Slope 0.021 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-21A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.017 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 2.18 cfs Results Normal Depth 3.4 in Flow Area 0.7 ft2 Wetted Perimeter 3.3 ft Hydraulic Radius 2.4 in Top Width 3.20 ft Critical Depth 3.9 in Critical Slope 0.010 ft/ft Velocity 3.28 ft/s Velocity Head 0.17 ft Specific Energy 0.45 ft Froude Number 1.271 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.4 in Critical Depth 3.9 in Channel Slope 0.017 ft/ft Critical Slope 0.010 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-21 B Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.017 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 1.28 cfs Results Normal Depth 2.6 in Flow Area 0.5 ftz Wetted Perimeter 2.8 ft Hydraulic Radius 1.9 in Top Width 2.78 ft Critical Depth 2.9 in Critical Slope 0.011 ft/ft Velocity 2.81 ft/s Velocity Head 0.12 ft Specific Energy 0.34 ft Froude Number 1.224 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.6 in Critical Depth 2.9 in Channel Slope 0.017 ft/ft Critical Slope 0.011 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-21 Calculate Skimmer Size Basin Volume in Cubic Feet 11,732 Cu.Ft Skimmer Size 2.0 Inch Days to Drain* 4 Days Orifice Radius 0.9 Inch[es] Orifice Diameter 1.8 Inch[es] "In NC assume 3 days to drain SB-22 Calculations: Worksheet for SB-22A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 6.39 cfs Results Normal Depth 6.5 in Flow Area 0.4 ftz Wetted Perimeter 1.7 ft Hydraulic Radius 3.2 in Top Width 1.00 ft Critical Depth 11.6 in Percent Full 54.3 % Critical Slope 0.096 ft/ft Velocity 14.67 ft/s Velocity Head 3.34 ft Specific Energy 3.89 ft Froude Number 3.910 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.110 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 54.3 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 6.5 in Critical Depth 11.6 in Channel Slope 0.333 ft/ft Critical Slope 0.096 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for SB-22B Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 0.85 cfs Results Normal Depth 2.2 in Flow Area 0.1 ftz Wetted Perimeter 0.9 ft Hydraulic Radius 1.4 in Top Width 0.78 ft Critical Depth 4.6 in Percent Full 18.7% Critical Slope 0.019 ft/ft Velocity 8.38 ft/s Velocity Head 1.09 ft Specific Energy 1.28 ft Froude Number 4.097 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.002 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 18.7% Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.2 in Critical Depth 4.6 in Channel Slope 0.333 ft/ft Critical Slope 0.019 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-22A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.080 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 3.30 cfs Results Normal Depth 2.8 in Flow Area 0.5 ftz Wetted Perimeter 3.0 ft Hydraulic Radius 2.1 in Top Width 2.89 ft Critical Depth 4.9 in Critical Slope 0.009 ft/ft Velocity 6.50 ft/s Velocity Head 0.66 ft Specific Energy 0.89 ft Froude Number 2.734 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.8 in Critical Depth 4.9 in Channel Slope 0.080 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-22B Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.080 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 3.09 cfs Results Normal Depth 2.7 in Flow Area 0.5 ftz Wetted Perimeter 2.9 ft Hydraulic Radius 2.0 in Top Width 2.84 ft Critical Depth 4.7 in Critical Slope 0.009 ft/ft Velocity 6.37 ft/s Velocity Head 0.63 ft Specific Energy 0.85 ft Froude Number 2.720 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.7 in Critical Depth 4.7 in Channel Slope 0.080 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-22C Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.080 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 0.85 cfs Results Normal Depth 1.3 in Flow Area 0.2 ft2 Wetted Perimeter 2.2 ft Hydraulic Radius 1.1 in Top Width 2.15 ft Critical Depth 2.3 in Critical Slope 0.011 ft/ft Velocity 4.26 ft/s Velocity Head 0.28 ft Specific Energy 0.39 ft Froude Number 2.470 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 1.3 in Critical Depth 2.3 in Channel Slope 0.080 ft/ft Critical Slope 0.011 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-22 Calculate Skimmer Size Basin Volume in Cubic Feet 58,016 Cu.Ft Skimmer Size 4.0 Inch Days to Drain* 4 Days Orifice Radius 1.7 Inch[es] Orifice Diameter 3.4 Inch[es] "In NC assume 3 days to drain SB-23 Calculations: Worksheet for SB-23A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 15.0 in Discharge 12.41 cfs Results Normal Depth 8.5 in Flow Area 0.7 ft2 Wetted Perimeter 2.1 ft Hydraulic Radius 4.0 in Top Width 1.24 ft Critical Depth 14.6 in Percent Full 56.7% Critical Slope 0.112 ft/ft Velocity 17.29 ft/s Velocity Head 4.65 ft Specific Energy 5.36 ft Froude Number 4.006 Maximum Discharge 21.72 cfs Discharge Full 20.19 cfs Slope Full 0.126 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 56.7% Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 8.5 in Critical Depth 14.6 in Channel Slope 0.333 ft/ft Critical Slope 0.112 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-23A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.052 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 1.07 cfs Results Normal Depth 1.7 in Flow Area 0.3 ft2 Wetted Perimeter 2.4 ft Hydraulic Radius 1.4 in Top Width 2.34 ft Critical Depth 2.6 in Critical Slope 0.011 ft/ft Velocity 3.96 ft/s Velocity Head 0.24 ft Specific Energy 0.38 ft Froude Number 2.056 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 1.7 in Critical Depth 2.6 in Channel Slope 0.052 ft/ft Critical Slope 0.011 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-23B Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.052 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 6.98 cfs Results Normal Depth 4.6 in Flow Area 1.0 ft2 Wetted Perimeter 3.9 ft Hydraulic Radius 3.1 in Top Width 3.80 ft Critical Depth 7.2 in Critical Slope 0.008 ft/ft Velocity 6.87 ft/s Velocity Head 0.73 ft Specific Energy 1.12 ft Froude Number 2.344 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 4.6 in Critical Depth 7.2 in Channel Slope 0.052 ft/ft Critical Slope 0.008 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-23C Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.052 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 4.37 cfs Results Normal Depth 3.6 in Flow Area 0.7 ftz Wetted Perimeter 3.4 ft Hydraulic Radius 2.6 in Top Width 3.31 ft Critical Depth 5.6 in Critical Slope 0.009 ft/ft Velocity 6.03 ft/s Velocity Head 0.57 ft Specific Energy 0.87 ft Froude Number 2.274 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.6 in Critical Depth 5.6 in Channel Slope 0.052 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-23 Calculate Skimmer Size Basin Volume in Cubic Feet 23,576 Cu.Ft Skimmer Size 2.5 Inch Days to Drain* 4 Days Orifice Radius 1.2 Inch[es] Orifice Diameter 2.4 Inch[es] "In NC assume 3 days to drain SB-24 Calculations: Worksheet for SB-24A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 6.07 cfs Results Normal Depth 6.3 in Flow Area 0.4 ftz Wetted Perimeter 1.6 ft Hydraulic Radius 3.1 in Top Width 1.00 ft Critical Depth 11.5 in Percent Full 52.6% Critical Slope 0.086 ft/ft Velocity 14.49 ft/s Velocity Head 3.26 ft Specific Energy 3.79 ft Froude Number 3.942 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.099 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 52.6% Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 6.3 in Critical Depth 11.5 in Channel Slope 0.333 ft/ft Critical Slope 0.086 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for SB-24B Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 1.12 cfs Results Normal Depth 2.6 in Flow Area 0.1 ftz Wetted Perimeter 1.0 ft Hydraulic Radius 1.5 in Top Width 0.82 ft Critical Depth 5.3 in Percent Full 21.4% Critical Slope 0.020 ft/ft Velocity 9.08 ft/s Velocity Head 1.28 ft Specific Energy 1.50 ft Froude Number 4.132 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.003 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 21.4% Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.6 in Critical Depth 5.3 in Channel Slope 0.333 ft/ft Critical Slope 0.020 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-24A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.052 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 1.12 cfs Results Normal Depth 1.7 in Flow Area 0.3 ft2 Wetted Perimeter 2.4 ft Hydraulic Radius 1.4 in Top Width 2.37 ft Critical Depth 2.7 in Critical Slope 0.011 ft/ft Velocity 4.01 ft/s Velocity Head 0.25 ft Specific Energy 0.39 ft Froude Number 2.055 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 1.7 in Critical Depth 2.7 in Channel Slope 0.052 ft/ft Critical Slope 0.011 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-24B Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.052 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 1.01 cfs Results Normal Depth 1.6 in Flow Area 0.3 ft2 Wetted Perimeter 2.4 ft Hydraulic Radius 1.3 in Top Width 2.32 ft Critical Depth 2.5 in Critical Slope 0.011 ft/ft Velocity 3.88 ft/s Velocity Head 0.23 ft Specific Energy 0.37 ft Froude Number 2.041 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 1.6 in Critical Depth 2.5 in Channel Slope 0.052 ft/ft Critical Slope 0.011 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-24C Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.052 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 5.06 cfs Results Normal Depth 3.9 in Flow Area 0.8 ft2 Wetted Perimeter 3.6 ft Hydraulic Radius 2.7 in Top Width 3.45 ft Critical Depth 6.1 in Critical Slope 0.009 ft/ft Velocity 6.27 ft/s Velocity Head 0.61 ft Specific Energy 0.94 ft Froude Number 2.286 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.9 in Critical Depth 6.1 in Channel Slope 0.052 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-24 Calculate Skimmer Size Basin Volume in Cubic Feet 20,947 Cu.Ft Skimmer Size 2.5 Inch Days to Drain* 4 Days Orifice Radius 1.1 Inch[es] Orifice Diameter 2.3 Inch[es] "In NC assume 3 days to drain SB-25 Calculations: Worksheet for SB-25A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 18.0 in Discharge 22.11 cfs Results Normal Depth 10.8 in Flow Area 1.1 ftz Wetted Perimeter 2.7 ft Hydraulic Radius 5.0 in Top Width 1.47 ft Critical Depth 17.7 in Percent Full 60.1 % Critical Slope 0.137 ft/ft Velocity 19.93 ft/s Velocity Head 6.17 ft Specific Energy 7.08 ft Froude Number 4.044 Maximum Discharge 35.32 cfs Discharge Full 32.83 cfs Slope Full 0.151 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 60.1 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 10.8 in Critical Depth 17.7 in Channel Slope 0.333 ft/ft Critical Slope 0.137 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for SB-25B Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 1.49 cfs Results Normal Depth 3.0 in Flow Area 0.2 ftz Wetted Perimeter 1.0 ft Hydraulic Radius 1.7 in Top Width 0.86 ft Critical Depth 6.2 in Percent Full 24.7% Critical Slope 0.021 ft/ft Velocity 9.87 ft/s Velocity Head 1.51 ft Specific Energy 1.76 ft Froude Number 4.158 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.006 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 24.7% Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.0 in Critical Depth 6.2 in Channel Slope 0.333 ft/ft Critical Slope 0.021 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.03] 2/1/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-25A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.033 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 21.47 cfs Results Normal Depth 8.8 in Flow Area 2.7 ftz Wetted Perimeter 6.2 ft Hydraulic Radius 5.3 in Top Width 5.91 ft Critical Depth 12.5 in Critical Slope 0.007 ft/ft Velocity 7.88 ft/s Velocity Head 0.96 ft Specific Energy 1.70 ft Froude Number 2.046 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 8.8 in Critical Depth 12.5 in Channel Slope 0.033 ft/ft Critical Slope 0.007 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-25B Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.033 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 64.00 cfs Results Normal Depth 14.4 in Flow Area 6.1 ft2 Wetted Perimeter 9.1 ft Hydraulic Radius 8.1 in Top Width 8.71 ft Critical Depth 20.6 in Critical Slope 0.006 ft/ft Velocity 10.43 ft/s Velocity Head 1.69 ft Specific Energy 2.89 ft Froude Number 2.190 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 14.4 in Critical Depth 20.6 in Channel Slope 0.033 ft/ft Critical Slope 0.006 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TO-25C Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.033 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 1.49 cfs Results Normal Depth 2.3 in Flow Area 0.4 ft2 Wetted Perimeter 2.7 ft Hydraulic Radius 1.8 in Top Width 2.65 ft Critical Depth 3.1 in Critical Slope 0.010 ft/ft Velocity 3.76 ft/s Velocity Head 0.22 ft Specific Energy 0.41 ft Froude Number 1.715 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 2.3 in Critical Depth 3.1 in Channel Slope 0.033 ft/ft Critical Slope 0.010 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.03] 6/5/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-25 Calculate Skimmer Size Basin Volume in Cubic Feet 44,244 Cu.Ft Skimmer Size 4.0 Inch Days to Drain* 4 Days Orifice Radius 1.5 Inch[es] Orifice Diameter 3.0 Inch[es] "In NC assume 3 days to drain SB-26 Calculations: Worksheet for SB-26A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 5.11 cfs Results Normal Depth 5.7 in Flow Area 0.4 ftz Wetted Perimeter 1.5 ft Hydraulic Radius 2.9 in Top Width 1.00 ft Critical Depth 11.1 in Percent Full 47.6 % Critical Slope 0.061 ft/ft Velocity 13.88 ft/s Velocity Head 2.99 ft Specific Energy 3.47 ft Froude Number 4.029 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.070 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 47.6 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 5.7 in Critical Depth 11.1 in Channel Slope 0.333 ft/ft Critical Slope 0.061 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.031 9/27/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TD-26A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.033 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 4.05 cfs Results Normal Depth 3.9 in Flow Area 0.8 ftz Wetted Perimeter 3.6 ft Hydraulic Radius 2.7 in Top Width 3.45 ft Critical Depth 5.4 in Critical Slope 0.009 ft/ft Velocity 5.03 ft/s Velocity Head 0.39 ft Specific Energy 0.72 ft Froude Number 1.838 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.9 in Critical Depth 5.4 in Channel Slope 0.033 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.031 9/27/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TD-26B Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.033 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 1.07 cfs Results Normal Depth 1.9 in Flow Area 0.3 ftz Wetted Perimeter 2.5 ft Hydraulic Radius 1.5 in Top Width 2.46 ft Critical Depth 2.6 in Critical Slope 0.011 ft/ft Velocity 3.40 ft/s Velocity Head 0.18 ft Specific Energy 0.34 ft Froude Number 1.674 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 1.9 in Critical Depth 2.6 in Channel Slope 0.033 ft/ft Critical Slope 0.011 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.031 9/26/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-26 Calculate Skimmer Size Basin Volume in Cubic Feet 17,725 Cu.Ft Skimmer Size 2.5 Inch Days to Drain* 4 Days Orifice Radius 1.1 Inch[es] Orifice Diameter 2.1 Inch[es] *In NC assume 3 days to drain SB-27 Calculations: Worksheet for SB-27A Slope Drain Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.024 Channel Slope 0.333 ft/ft Diameter 12.0 in Discharge 4.21 cfs Results Normal Depth 5.1 in Flow Area 0.3 ftz Wetted Perimeter 1.4 ft Hydraulic Radius 2.7 in Top Width 0.99 ft Critical Depth 10.4 in Percent Full 42.6 % Critical Slope 0.044 ft/ft Velocity 13.19 ft/s Velocity Head 2.71 ft Specific Energy 3.13 ft Froude Number 4.096 Maximum Discharge 11.98 cfs Discharge Full 11.14 cfs Slope Full 0.048 ft/ft Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Average End Depth Over Rise 0.0 % Normal Depth Over Rise 42.6 % Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 5.1 in Critical Depth 10.4 in Channel Slope 0.333 ft/ft Critical Slope 0.044 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Sediment Basins Temp Pipes.fm8 Center [10.03.00.031 9/26/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TD-27A Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.033 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 3.14 cfs Results Normal Depth 3.4 in Flow Area 0.7 ftz Wetted Perimeter 3.3 ft Hydraulic Radius 2.4 in Top Width 3.21 ft Critical Depth 4.7 in Critical Slope 0.009 ft/ft Velocity 4.68 ft/s Velocity Head 0.34 ft Specific Energy 0.63 ft Froude Number 1.807 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 3.4 in Critical Depth 4.7 in Channel Slope 0.033 ft/ft Critical Slope 0.009 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.031 9/26/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 Worksheet for TD-27B Ditch Calculations Project Description Friction Method Manning Formula Solve For Normal Depth Input Data Roughness Coefficient 0.020 Channel Slope 0.033 ft/ft Left Side Slope 3.000 H:V Right Side Slope 3.000 H:V Bottom Width 1.50 ft Discharge 1.07 cfs Results Normal Depth 1.9 in Flow Area 0.3 ftz Wetted Perimeter 2.5 ft Hydraulic Radius 1.5 in Top Width 2.46 ft Critical Depth 2.6 in Critical Slope 0.011 ft/ft Velocity 3.40 ft/s Velocity Head 0.18 ft Specific Energy 0.34 ft Froude Number 1.674 Flow Type Supercritical GVF Input Data Downstream Depth 0.0 in Length 0.0 ft Number Of Steps 0 GVF Output Data Upstream Depth 0.0 in Profile Description N/A Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 1.9 in Critical Depth 2.6 in Channel Slope 0.033 ft/ft Critical Slope 0.011 ft/ft Bentley Systems,Inc. Haestad Methods Solution FlowMaster Ditch Calcs.fm8 Center [10.03.00.031 9/26/2023 27 Siemon Company Drive Suite 200 W Page 1 of 1 Watertown,CT 06795 USA +1-203-755-1666 SB-27 Calculate Skimmer Size Basin Volume in Cubic Feet 18,083 Cu.Ft Skimmer Size 2.5 Inch Days to Drain* 4 Days Orifice Radius 1.1 Inch[es] Orifice Diameter 2.1 Inch[es] *In NC assume 3 days to drain 6/5/23, 11:47AM ECMDS 7.0 NORTH North American Green AMERICAN 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 61 GREEN Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 CHANNEL ANALYSIS >>>TEMPORARY DITCHES Name TEMPORARY DITCHES Discharge 36.28 Channel Slope 0.068 Channel Bottom Width 3 Left Side Slope 3 Right Side Slope 3 Low Flow Liner Retardence Class C 6-12 in Vegetation Type Mix(Sod and Bunch) Vegetation Density Good 65-79% Soil Type Clay Loam(CL) SC250 Normal Permissible Calculated Safety Staple Phase Reach Discharge Velocity Depth Mannings N Shear Stress Shear Stress Factor Remarks Pattern SC250 Straight 36.28 cfs 11.38 ft/s 0.65 ft 0.02 3 Ibs/ft2 2.74 Ibs/ft2 1.09 STABLE E Unvegetated Underlying Straight 36.28 cfs 11.38 ft/s 0.65 ft 0.02 3.27 Ibs/ft2 1.91 Ibs/ft2 1.71 STABLE E Substrate SC250 Straight 36.28 cfs 11.38 ft/s 0.65 ft 0.02 10 Ibs/ft2 2.74 Ibs/ft2 3.65 STABLE E Reinforced Vegetation Underlying Straight 36.28 cfs 11.38 ft/s 0.65 ft 0.02 3 Ibs/ft2 1.91 Ibs/ft2 1.57 STABLE E Substrate Based on TD-2B being the "worst case"scenario, SC250 will be used for all ditches. https://ecmds.com/project/155201/channel-analysis/238549/show 1/1 Pre Developed Calculations: / �/ 1 �\ ! % \\ + \ \\ \ \I I RA40 UNION CO. \ { 1 ` i/ f NORTH GRAHAM 05144007E ) ` ` \ \ \ \ f 223CHARLOTTE,NC 28202 ET MVESA DRAEP D 8 / \ I\ \\ \ // // / ^\ l /r L ) LAND ESIG / ` \YY ((( (\ WWW.LAND3.0325.COM \ \ WAX REHOBE�H RO \ / ~ \J WAXHAW.NC281]3 /\ \ ♦ — ) j DRAINAGEAREA 7.56 AC \ EXIST.STREAM / RA40(UNION CO_) / CATLETT AT r ` \ ( / 5015 RE BE HRD�l"I ` )1 f )$ I \` KI�E ' 'R0(WAXH3WWAXHA NC 28173 t/ VER ARNOT HENRYJII \j05�170]4W) /' /3026 WAXHAW CROSSING D ' �A ROBERT DAVIR JR& WAXHAW,NC 2P173 020 WA HAW CROSSIN DR SEDIMENT k, j AAE�66LLAMLESLIE \ �-t WAXI7AW,NC 28173 BASIN-19 DRAINAGE AREA,3.19 ACKEY R-2(WAXHAW) ) 1 �/ 05117072MILDRE R-2(117073 ) / BARCA LOUIS& n / 05117073 \ / \ / O r D \� \ 1 ( / 1MEVERARNOT J� / 4000WDJANE / °�6 ( F 1 \ / 4000 WAXHAW J HENRY JRB // CROSS ING DR / R-2(WAXHAW) EXISTING RAN / l \ / Jc \ 'Jp28 WAXHAJWJ�/ / HAW,NC 281� / 05117071 STEV \ // (TIP) I ti �\ r / \ (� WA�)(OW,INC R�/ /// SPULER STEVEN& \ / //� ❑ / 06 WAXHAW \ ///'J` �� I� i� \ s� \ � \ I � f r ♦ coos waxHAw WAXHAW,NC'Pi:73 / SEDIMENT ♦ / // \ SEDIMENT �{�. ♦ \� / / r✓1 \ \ f / BASIN-18 I \I BASIN-1 RA-40NNI04CO.) r -'y ` DRAINAGE \ �� PROPERTY I / DRAINAGE �- \ o51a400FF L ( / AREA:4;65 AC ~\ \ \ / S \BOUNDARY(TVP) , BRU(SWELL JAMES JR&DEBRA P ( / / ~\ / \ wAREA:33.6 AC \ ♦ 1// \ \ FrvIP)STREAM\ / WA REH,N 28 73 / f / ,( / \/ \ ` Z \ ~\ Xi �-�R-051J17070W) \ 1 11/ < CO WAXHAW,N 28173 / \l .� WA%HAW VENTURES LLC 1\ SEDIMENT f° �r l 1 \ f 11 MAT HEWS,NC RD104 BASIN-21 / DRAINAGE / 4 - �% A�2EA:0.80AC \R-2(vK�AXHAW) ,\ — —/— — a S \ 7 ` / SEDIMENT o51d1011A I I r ( ( J r SEDIMENT BASIN-2 _ 1 \ R-z(wA%HAw) 5 15f�PI 5ARAHG 1 BASIN-17 1 ( I \) '1 7 05117083 I 3715 HELMS RD I I \ / - / I I / DRAINAGE WAXHAW VENTURES LLC ` LANCASTER,SC 29720 I I a 1 / / / 7 DRAINAGE (\ I)I �\ AREA:7.48 AC ( 5615 POTTER RD 1 ` I SEDIMENT S REA:1.55AC T \ — R-2(WAXHAW) 1 \ \�• S '\ r ` f\ / 1 MATTHEWS,NC 28104 0514400sj\ 1 BASIN-22 I �__ ^ IGORDONGARRV MICHAE \ 11 \ 1 1 \ DRAINAGE \ t r \ ` -1---- f 1 L----/-- — 1 I } -. \ r.✓" J I _< — ( 1 PROPERTY (TYP) 5205 REHOBETH RD II \ Y R-2(117082 ) '(\WAXHAW,NC 28173 \ ` L■ AREA: 50 AC \ ) 1 ,-� r' os11]o8z I \ I \ L tl I • ` I I ` 7 \ \ \ WAXHAW VENTURES LLC 1 1 5615 POTTER RD R-2(WA%HAW)\ 1 \/ \ \ �p T' \ \ ' MATTHEWS.NC 28104 1 VERHART SH RRV G�I °jO\ ' 5209 REHOBETH RD WAXHAW,INC 28173 {�I � � \ / 1 ) / \ \ ✓ l� � � 1 � R-2(WAXHAW) 1 1 ) \ \l \ \ \\ ..., r 0511NTU 1) 1 Pao,E°T J WAXHAW VENTURES LLC SEDIMENT tV sx 1 I 5815 POTTER RD _�` J \\ \ I \~ J \� \ r f ) BASIN-16 \\\ \ 2 SEDIMENT r' f^ I I 1 MATTHEWS,NC28104_-- ,1 THE PRESERVE SEDIMENT J f DRAINAGE e° \ s' -- BASIN-23 / / I r 1 1 1 BASIN-3 \ I --_ _- AT FOREST DRAINAGE AREA:5.14 1 DRAINAGE ^ �— R-2(WAXHAW) r / m ! t \ 1 11 f CREEK- PHASE 2 ^w j AREA:2.58 AC r j \ \ / /r /AREA:/3.06 AC i f( SMALL R DICKS SON& \ I( / s~ I ALLLAURI D RD BFON 5018 WAXHAW CROSSING DR_ LENNAR WAXHAW NC 281'73__—_\/ �_— 1 6701 CARMEL ROAD,SUITE 425 r �1 R-2(WAXHAW) I 151170s7 I 1 CHARLOTTE,NC 28226 \ ` PEREZ NICOL ASS& THANGPANHARA } \ \ \1 1 1 1 ( rly 5T WAXHAW CROSSING DR SEDIMENT / \ ` \ ( \ < y wA%HAza_ {� BASIN-24 /'- \ DRAINAGE ? `0 I 7 I !F / ) SEDIMENT R-2(WAXHAW) AREA:1.59 AC a I S BASIN-4 1 I i uND0E51GNP�OJ� 1oz11a3 05117055 / Jl Y �) � �( �� DRAINAGE f �� 1 Ds ss aocK�v am�� 1 R-2 144014 W) \ r \u" ) J I 1 MONROE,NC 2— _—=__ REVISION/ISSUANCE WWILLIAMSIMO ) \, f\ / I \ ) % / SEDIMENT ( ( / /f f AREA:3 66 AC r f ' _ WILLIAMS TIMOTII�'B 1\\ I 1 _ _ \ /Z 5223 REHOBETJJII RD / /J S (' / 1 / \� �, / r BASIN-15 J ..q 1 I '\� WAXHAI NC`28173 DRAINAGE / ) I \1 —_�_--- 1 NO. DESCRIPTION DATE (WAXHAW) AREA:1.29 AC 1 1 1ST-CD SUBMITTAL 05/06/22 ti- 05117054 VETTERPATRICIA T 1 5042 WAXHAW CROSSING DR —I 2 ND-CD SUBMITTAL 10/14/22 WAXHAW,INC 28173 3 RD-CD SUBMITTAL 01/12/23 I I �o J I SEDIMENT / \ i / �� j•• �S f ) J I \I _ _ BASIN-14I\--=_—__-- I I 30'STREAMBUFFER DRAINAGE / / , / �11 ° II) 1 \ R-z —� — (TVP) \ \ \1 ` SEDIMENT i� I•� (�.. ` \ �,C I I (WAXHAW) BASIN AREA/,47 AC rf / �� / l ° � �( 11 \ SMITH BRAD05117053 C& — SO-STREAM BUFFER DRAINAGE r ) Jul {_ \ J 'I SMQH JOLENE NICOLE — (TYP) \ \ AREA:1.,2AC I i / /' �— I I I ) \ II_ 5048WA%A ,HAW VC2817733cere-- EXIST.BOUNDARY LINE ' EXIST.MAJOR CONTOUR — — 570 — — r R-2(WAXHAW� EXIST.MINOR CONTOUR ----568 ---- 051a4099 �� WILLIAMS BRADLEY FRANK EXIST.STORM DRAINAGE ST 5229 REHOBETH RD 1 SEE SHEET C414 FOR CONTINUATION EXIST.R/W WAXHAW,NC 28173 ` \ IJ n \ \ EXIST.TREELINE CAP EXIST.PROPERTY LINE DRAWN BY: STB EXIST.STORM DRAIN MANHOLE s� CHECKED BY: MLG EXIST.CATCH BASIN ® Eo° DRAINAGE AREA LIMITS __________ ORTM (SEDIMENT BASIN) HORZ: 1"50. SOIL TYPES DRAINAGE AREA(TREATED BY r————————1 CeB2 CECIL GRAVELLY SANDY CLAY,2 TO 8 PERCENT SLOPES(GROUP B) 0 z5 50, 100, HIGH HAZARD SILT FENCE) L—--—————J CeC2 CECIL GRAVELLY SANDY CLAY,8 TO 15 PERCENT SLOPES(GROUP B) SHEETTIT" LIMITS OF CONSTRUCTION/ AeB AILEY-APPLING COMPLEX(GROUP A) PRE-DEVELOPMENT CLEARING LIMITS DRAINAGE AREA MAP IEU NUMBER EXHIBIT SEE SHEET C413 FOR CONTINUATION T����TJ V WAXHAW VENTURES LLC 11 +-���+M+� n. 5615 POTTER RD 1 MATTHEWS,NC 28104 _ I I 1 223 NORTH GRAHAM STREET CHARLOTTE,NC 28202 704.333.0325 \ \ \ / / / �- 1 / / L �_• I 1--- - I 1 I I W WW.LANDDESIGN.COM R-2(WAXHAW) 1 1 WAXHAW VENTURES LLC 11 I I / 1 C cw... \ \} \ �\ \\ /- m r 11 ! 5815 POTTER RD 281o4 \` \ I v \ y _ \� J MATTHEWS,NC\ SEDIMENT > SEDIMENT \ N f / t BASIN-16 sao SEDIMENT - __- �. BASIN-2 / I DRAINAGE �� l I BASIN-3 DRAINAGE \ ( 1 1 J / DRAINAGE r ( _ R-2(WAXHAW) \ 1 / F AREA:2.58 AC r� m ( AREA:5.14 AC \ I05117058 j \ �\ / (T •J N( f AREA:3.06 AC / j r SMALL RICHARD BRICE 8, 1 f ( 111 5018 WAXHAW CROSSING I 1 N / �6^� �.`r / m { 1 \l /�s� I1� / / \ I WAXHAW NC28173�: 1 %. I r J \1 Z ( (l 1 -- R-2(WAXHAW) 1 LINE(TVP) �� -`I\ ` �1-� �- PEREZSNICOLAS S �/ L Z \ I \ / \ \ \ I 1 \ R 1 .\ I THANG PANHARA / z 1 1 -1—�' \ \,\ ( \ \ ) 1 50$4 WAXHAW CROSSING DR 1 \ SEDIMENT r\ ` ` WAXHAW,NC2� 3 _ �m \��I j BASIN-24 DRAINAGE \ ? `0 ` ) ( / ^{ ? \-� 1-2(WAXHAW) M f l AREA:1,. CLA�ONsi 59 AC I / I S 1 f r / 1 1 OvoSs / I \—_ / ry RVAN HOMES LL7C 1 • \ / // r I J 1 5315`SROCKYRIVE"D 1 1 J I �u '✓� ) ,+ '/ ( / F �� r f/ II 11 MONROE,NC 28112 'SEDIMENT / - I n •��� \ ��Iy \ o_ti 1 �� j / I ^/ SEDIMENT �\�1 _ R o(WAXHAW) — DRAINAGE BASIN-4 M DRAINAGE KEY II VETTER PATRICIAT \ AREA:1 29 AC ) i S \ ^\ ( AREA:3.66 AC 1 \`1 5042 WAXHAW CROSSING DR WAXHAW,INC 28173 SEDIMENT - I SEDIMENT _ --- _ DRAINAGE ( BASIN-14 / "/ y / °(�I�} ( 1 I-� R-2(WAXHAW) \ \ `AREA:1.22 AC I DRAINAGE \ ARE P� 1.47 AC r / / / / \ 0 H BRA 3 _ I \ \� J SMITH BRAD & SMITH JOLENE NICOLE 5048 W HAW CROSSJNG SSJNG 43R- �I \ �• \� � I ��� J � .�/ WAXHIiW.NC� __ � - r R-2(WAXHAW)\�\mot ( ) �� - sEAL ILLIAMS 051 099LEY FRANKL71� ( (I t: \ / /$ / _F I I l / - \ — JC L j SEDIMENT 5229 REHOBETH RD \ \ BASIN-5 WAXHAW,NC 28173 y \ 1 / (� g' ::: �~\ /� �/ J r` \ ` \ \ 4� ( DRAINAGE _— �. AREA:3.77 AC �) / ( % i\•`W•� 1/ 9 \ / / 1 R-2(WAXHAW) i' v r•^•.::: �..�.•: / 1 I 11 05117052 -- 'IC535SROCKV RNEE&DC\ - _ SEDIMENT —' \ 1 BASIN-10 \ ) \ \.. 1 l v r f I,I Ea sz� DRAINAGE AREA:12.58 AC \ / 2 ' III R UEEa(51 051 \1 SEDI NT I EAMANDAPATRICK B I _ SEDIMENT S f'� \ BASIN-6 oosWAXC�ROssG�rr- \ DRAINAGE II -- - - r SEDIMENT � BASIN-11 � � ( 1 \ � ��\ \ / BASIN-12 - DRAINAGE ( I \ ) \ ° \ I AREA:4.6 AC -r (� DRAINAGE r DRAINAGE R-2(`THAW) I�A EA:1.09 AC �/ \ �l a I \ I,Fq S?N EDWA I \ I �'+�_- �, ROBI N EDWARD P 8 I Z ( SEDIMENT ro8150N KEELVM { BASIN-9 \ f �•I v:::;;� �Y �, NRLOT.-STAPT 209----J \ I 1 HA RLOIIE;IdC2�202—__ -- H-2(WAXHAW) \ \ 1 DRAINAGE ::::.fi;`:; _ 05144014B / ...:.... "v1 D�VIS IRIS COCHRELL/ I B ,)) \ / AREA:2.77 AC I / ;-: / 1 1 1 41 11-2(WAXHAW) .{/ 37403TONEHAVEN QR 1 `:::::::::. / \ / ` 05117049 I \ 2' \ \ _I o 1 \ �• •••••••• / / / (" WHITE RAVMOND/ vaa[ci \ CHARLOTTE,NC 28 15 / ` \ \ \ - F•i::•...:•..•'' / \ I6 WW THE PRESERVE SEDIMENT �� __ _ AT FOREST J S I BASIN-25 CREEK SE 2 DRAINAGE K- PHA \ ( �........ _ / �• \ \J / AREA:4.92AC -+-�_- LENNAR R-2(WAXHAW) f \ •\ 05117048 I _ 6701 CARMEL ROAD,SUITE 425 SEDIMENT / 1 5 SIMS ROAD OF — BASIN-7 1 \ A� (_ NIC I —_ CHARLOTTE,NC 28226 ,AREA: 1.72 AC �� 1 ( �ReE E Na111 �\ _ — — ( 1 s I R-2(WAXHAW) I / / I r o f n • S '' \. 05117047 // :_• \ ( X° 1 SIMS ROAD OF /_ \ SEDIMENT / \ \ UNION, Pa°'." PO BOX / r J % 1 S�j may , 1oz11a3 \ BASIN-8 / DRAINAGE / \ \\\' EXIST.STREAM \ REVISION/ISSUANCE °AREA:1.40 AC (TYP) \ 3 !%1WA HAW) NO. DESCRIPTION DATE SIMS ROAD OF \ / R-2(WAXHAW) \ \ / .� / & I •I / �\ UN I ,LLC 1 1ST-CDSUBMITTAL 05/06/22 30'STREAM BUFFER \\ PO B X 748 \ / 05144015 ` J / I I _ (TVP) I�NROE,N 28111 DOUGHry ANN MARIE v r ) ( j I• ( f \ \ \ 2 ND-CD SUBMITTAL 10/14/22 446 GULL CT NORTH PALM BEACH,FL 340 \ —-r_iw •^-_ / �. / `� I \\l X} X ( / I � .2 44 I -•�Cs- \ / // 3 RD-CD SUBMITTAL 01/12/23 50'STREAM BUFFER( P) I, SIOX NDANI SIMONLxWSS / WAXHAW,NC 28173 \ f r PROJECT/ \\ C� -2fWAXHAW) \' v ti ^���•� ( I / BOUNDARY L J 2 05144002G I \ \ ti- -� ` MILLER BRYCE L 8 EXIST.BOUNDARY LINE 70 J JY MILLERROBYND \ EXIST.MAJOR CONTOUR — — 570 — — - - S S a 7424 SIMS RD \ EXIST.MINOR CONTOUR ----568 ---- r \ WAXHAW,NC 28173 I \ EXIST.STORM DRAINAGE ST - \ \ R-2(WAXHAW) r \ \ EXIST.RAN / 05144002C DEVANEV JEANINE C EXIST.TREELINE 7606 SIMS RD CAP EXIST.PROPERTY LINE WAXHAW,NC 28173 DRAWN BY: STB EXIST.STORM DRAIN MANHOLE CHECKED BY: MLG EXIST.CATCH BASIN J \ \SOIL TYPES s°ACE "°"TM DRAINAGE AREA LIMITS (SEDIMENT BASIN) ---------- CeB2 CECIL GRAVELLY SANDY CLAY,2 TO 8 PERCENT SLOPES(GROUP B) / \ \ VERT: N/A CeC2 CECIL GRAVELLY SANDY CLAY,8 TO 15 PERCENT SLOPES(GROUP B) \ HORZ: 1'=100' DRAINAGE AREA(TREATED BY r 1 AeB AILEY-APPLING COMPLEX(GROUP A) \ 0 50, ioo' 200' HIGH HAZARD SILT FENCE) L. _____J \ SHEET TITLE LIMITS OF CONSTRUCTION/ \ \ PRE-DEVELOPMENT CLEARING LIMITS \ DRAINAGE AREA MAP "EET"uEXHIBIT Time of Concentration - BMP-7 DA Pre-Developed TOC Pre Developed Drainage Area Sheet Flow: n: 0.41 L: 100 ft P2: 3.55 in s: 0.051 ft/ft T: 0.239 hr Shallow Concentrated Flow: L: 532 ft s: 0.086 ft/ft Type 2 (1=paved/2= unpaved) V= 4.73 fps T= 0.031 hr Open Channel: L: 500 ft V: 5 fps (assumed) T= 0.028 hr Total: 0.298 hr 17.9 m i n Time of Concentration - BMP-8 DA Pre-Developed TOC Pre Developed Drainage Area Sheet Flow: n: 0.41 L: 100 ft P2: 3.55 in s: 0.080 ft/ft T: 0.199 hr Shallow Concentrated Flow: L: 500 ft s: 0.090 ft/ft Type 2 (1=paved/2= unpaved) V= 4.84 fps T= 0.029 hr Open Channel: L: 280 ft V: 5 fps (assumed) T= 0.016 hr Total: 0.243 hr 14.6 m i n Time of Concentration - BMP-9 DA Pre-Developed TOC Pre Developed Drainage Area Sheet Flow: n: 0.41 L: 100 ft P2: 3.55 in s: 0.060 ft/ft T: 0.223 hr Shallow Concentrated Flow: L: 797 ft s: 0.071 ft/ft Type 2 (1=paved/2= unpaved) V= 4.30 fps T= 0.051 hr Open Channel: L: 639 ft V: 5 fps (assumed) T= 0.036 hr Total: 0.310 hr 18.6 m i n Time of Concentration- BMP-10 DA Pre-Developed TOC Pre Developed Drainage Area Sheet Flow: n: 0.41 L: 100 ft P2: 3.55 in s: 0.050 ft/ft T: 0.240 hr Shallow Concentrated Flow: L: ft s: ft/ft Type (1=paved/2= unpaved) V= 2.28 fps T= 0.047 hr Open Channel: L: 1425 ft V: 5 fps (assumed) T= 0.079 hr Total: 0.366 hr 22.0 m i n Time of Concentration - BMP-11 DA Pre-Developed TOC Pre Developed Drainage Area Sheet Flow: n: 0.41 L: 100 ft P2: 3.55 in s: 0.056 ft/ft T: 0.230 hr Shallow Concentrated Flow: L: 659 ft s: 0.079 ft/ft Type 2 (1=paved/2= unpaved) V= 4.53 fps T= 0.040 hr Open Channel: L: 700 ft V: 5 fps (assumed) T= 0.039 hr Total: 0.309 hr 18.5 m i n Time of Concentration - BMP-12 DA Pre-Developed TOC Pre Developed Drainage Area Sheet Flow: n: 0.41 L: 100 ft P2: 3.55 in s: 0.051 ft/ft T: 0.238 hr Shallow Concentrated Flow: L: 619 ft s: 0.103 ft/ft Type 2 (1=paved/2= unpaved) V= 5.18 fps T= 0.033 hr Open Channel: L: 652 ft V: 5 fps (assumed) T= 0.036 hr Total: 0.308 hr 18.5 m i n Table of Contents Master Network Summary 1 Union County Time-Depth Curve, 2 years(Union County-Synthetic Curve, 2 5 yrs) Time-Depth Curve, 10 years(Union County-Synthetic Curve, 7 10 yrs) Time-Depth Curve, 25 years(Union County-Synthetic Curve, 9 25 yrs) Time-Depth Curve, 50 years(Union County-Synthetic Curve, 11 50 yrs) Time-Depth Curve, 100 years(Union County-Synthetic Curve, 13 100 yrs) PRE-AREA-10 Runoff CN-Area, 2 years(Union County-Synthetic Curve, 2 15 yrs) PRE-AREA-11 Runoff CN-Area, 2 years(Union County-Synthetic Curve, 2 16 yrs) PRE-AREA-12 Runoff CN-Area, 2 years(Union County-Synthetic Curve, 2 17 yrs) PRE-AREA-7 Runoff CN-Area, 2 years(Union County-Synthetic Curve, 2 18 yrs) PRE-AREA-8 Runoff CN-Area, 2 years(Union County-Synthetic Curve, 2 19 yrs) PRE-AREA-9 Runoff CN-Area, 2 years(Union County-Synthetic Curve, 2 20 yrs) Subsection: Master Network Summary Catchments Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Event Volume (hours) (ft3/s) (years) (ac-ft) PRE-AREA-7 Union County- 2 0.275 12.200 1.06 Synthetic Curve, 2 yrs PRE-AREA-7 Union County- 10 0.968 12.120 9.48 Synthetic Curve, 10 yrs PRE-AREA-7 Union County- 25 1.550 12.110 17.46 Synthetic Curve,25 yrs PRE-AREA-7 Union County- 50 2.079 12.080 24.99 Synthetic Curve, 50 yrs PRE-AREA-7 Union County- 100 2.731 12.080 34.36 Synthetic Curve, 100 yrs PRE-AREA-10 Union County- 2 0.379 12.200 2.50 Synthetic Curve, 2 yrs PRE-AREA-10 Union County- 10 1.079 12.150 10.96 Synthetic Curve, 10 yrs PRE-AREA-10 Union County- 25 1.631 12.150 17.90 Synthetic Curve,25 yrs PRE-AREA-10 Union County- 50 2.120 12.110 24.04 Synthetic Curve, 50 yrs PRE-AREA-10 Union County- 100 2.711 12.110 31.60 Synthetic Curve, 100 yrs PRE-AREA-8 Union County- 2 0.518 12.110 4.39 Synthetic Curve, 2 yrs PRE-AREA-8 Union County- 10 1.475 12.060 18.62 Synthetic Curve, 10 yrs PRE-AREA-8 Union County- 25 2.229 12.050 30.26 Synthetic Curve,25 yrs PRE-AREA-8 Union County- 50 2.897 12.050 40.58 Synthetic Curve, 50 yrs PRE-AREA-8 Union County- 100 3.705 12.050 52.96 Synthetic Curve, 100 yrs PRE-AREA-9 Union County- 2 0.362 12.190 1.64 Synthetic Curve, 2 yrs Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition Pre-Developed(Pre DAs).ppc Center [10.02.00.01] 6/22/2023 27 Siemon Company Drive Suite 200 W Page 1 of 21 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Master Network Summary Catchments Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Event Volume (hours) (ft3/s) (years) (ac-ft) PRE-AREA-9 Union County- 10 1.211 12.110 11.94 Synthetic Curve, 10 yrs PRE-AREA-9 Union County- 25 1.914 12.110 21.58 Synthetic Curve,25 yrs PRE-AREA-9 Union County- 50 2.549 12.110 30.33 Synthetic Curve, 50 yrs PRE-AREA-9 Union County- 100 3.329 12.110 40.99 Synthetic Curve, 100 yrs PRE-AREA-11 Union County- 2 0.237 12.150 1.74 Synthetic Curve, 2 yrs PRE-AREA-11 Union County- 10 0.675 12.110 7.55 Synthetic Curve, 10 yrs PRE-AREA-11 Union County- 25 1.020 12.110 12.29 Synthetic Curve,25 yrs PRE-AREA-11 Union County- 50 1.326 12.110 16.46 Synthetic Curve, 50 yrs PRE-AREA-11 Union County- 100 1.695 12.070 21.50 Synthetic Curve, 100 yrs PRE-AREA-12 Union County- 2 0.263 12.150 1.93 Synthetic Curve, 2 yrs PRE-AREA-12 Union County- 10 0.748 12.110 8.37 Synthetic Curve, 10 yrs PRE-AREA-12 Union County- 25 1.130 12.110 13.63 Synthetic Curve,25 yrs PRE-AREA-12 Union County- 50 1.468 12.080 18.31 Synthetic Curve, 50 yrs PRE-AREA-12 Union County- 100 1.878 12.080 24.00 Synthetic Curve, 100 yrs Node Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Event Volume (hours) (ft3/s) (years) (ac-ft) Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition Pre-Developed(Pre DAs).ppc Center [10.02.00.01] 6/22/2023 27 Siemon Company Drive Suite 200 W Page 2 of 21 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Master Network Summary Node Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Event Volume (hours) (ft3/s) (years) (ac-ft) OUTFALL-7 Union County- 2 0.275 12.200 1.06 Synthetic Curve, 2 yrs OUTFALL-7 Union County- 10 0.968 12.120 9.48 Synthetic Curve, 10 yrs OUTFALL-7 Union County- 25 1.550 12.110 17.46 Synthetic Curve,25 yrs OUTFALL-7 Union County- 50 2.079 12.080 24.99 Synthetic Curve, 50 yrs OUTFALL-7 Union County- 100 2.731 12.080 34.36 Synthetic Curve, 100 yrs OUTFALL-8 Union County- 2 0.518 12.110 4.39 Synthetic Curve, 2 yrs OUTFALL-8 Union County- 10 1.475 12.060 18.62 Synthetic Curve, 10 yrs OUTFALL-8 Union County- 25 2.229 12.050 30.26 Synthetic Curve,25 yrs OUTFALL-8 Union County- 50 2.897 12.050 40.58 Synthetic Curve, 50 yrs OUTFALL-8 Union County- 100 3.705 12.050 52.96 Synthetic Curve, 100 yrs OUTFALL-9 Union County- 2 0.362 12.190 1.64 Synthetic Curve, 2 yrs OUTFALL-9 Union County- 10 1.211 12.110 11.94 Synthetic Curve, 10 yrs OUTFALL-9 Union County- 25 1.914 12.110 21.58 Synthetic Curve,25 yrs OUTFALL-9 Union County- 50 2.549 12.110 30.33 Synthetic Curve, 50 yrs OUTFALL-9 Union County- 100 3.329 12.110 40.99 Synthetic Curve, 100 yrs OUTFALL-10 Union County- 2 0.379 12.200 2.50 Synthetic Curve, 2 yrs Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition Pre-Developed(Pre DAs).ppc Center [10.02.00.01] 6/22/2023 27 Siemon Company Drive Suite 200 W Page 3 of 21 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Master Network Summary Node Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Event Volume (hours) (ft3/s) (years) (ac-ft) OUTFALL-10 Union County- 10 1.079 12.150 10.96 Synthetic Curve, 10 yrs OUTFALL-10 Union County- 25 1.631 12.150 17.90 Synthetic Curve,25 yrs OUTFALL-10 Union County- 50 2.120 12.110 24.04 Synthetic Curve, 50 yrs OUTFALL-10 Union County- 100 2.711 12.110 31.60 Synthetic Curve, 100 yrs OUTFALL-11 Union County- 2 0.237 12.150 1.74 Synthetic Curve, 2 yrs OUTFALL-11 Union County- 10 0.675 12.110 7.55 Synthetic Curve, 10 yrs OUTFALL-11 Union County- 25 1.020 12.110 12.29 Synthetic Curve,25 yrs OUTFALL-11 Union County- 50 1.326 12.110 16.46 Synthetic Curve, 50 yrs OUTFALL-11 Union County- 100 1.695 12.070 21.50 Synthetic Curve, 100 yrs OUTFALL-12 Union County- 2 0.263 12.150 1.93 Synthetic Curve, 2 yrs OUTFALL-12 Union County- 10 0.748 12.110 8.37 Synthetic Curve, 10 yrs OUTFALL-12 Union County- 25 1.130 12.110 13.63 Synthetic Curve,25 yrs OUTFALL-12 Union County- 50 1.468 12.080 18.31 Synthetic Curve, 50 yrs OUTFALL-12 Union County- 100 1.878 12.080 24.00 Synthetic Curve, 100 yrs Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition Pre-Developed(Pre DAs).ppc Center [10.02.00.01] 6/22/2023 27 Siemon Company Drive Suite 200 W Page 4 of 21 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Time-Depth Curve Return Event: 2 years Label: Union County Storm Event: TypeII 24hr (3.6 in) Scenario: Union County- Synthetic Curve, 2 yrs Time-Depth Curve: TypeII 24hr(3.6 in) Label TypeII 24hr(3.6 in) Start Time 0.000 hours Increment 0.100 hours End Time 24.000 hours Return Event 2 years CUMULATIVE RAINFALL (in) Output Time Increment = 0.100 hours Time on left represents time for first value in each row. Time Depth Depth Depth Depth Depth (hours) (in) (in) (in) (in) (in) 0.000 0.0 0.0 0.0 0.0 0.0 0.500 0.0 0.0 0.0 0.0 0.0 1.000 0.0 0.0 0.0 0.0 0.1 1.500 0.1 0.1 0.1 0.1 0.1 2.000 0.1 0.1 0.1 0.1 0.1 2.500 0.1 0.1 0.1 0.1 0.1 3.000 0.1 0.1 0.1 0.1 0.1 3.500 0.1 0.2 0.2 0.2 0.2 4.000 0.2 0.2 0.2 0.2 0.2 4.500 0.2 0.2 0.2 0.2 0.2 5.000 0.2 0.2 0.2 0.2 0.3 5.500 0.3 0.3 0.3 0.3 0.3 6.000 0.3 0.3 0.3 0.3 0.3 6.500 0.3 0.3 0.3 0.3 0.3 7.000 0.4 0.4 0.4 0.4 0.4 7.500 0.4 0.4 0.4 0.4 0.4 8.000 0.4 0.4 0.4 0.5 0.5 8.500 0.5 0.5 0.5 0.5 0.5 9.000 0.5 0.5 0.6 0.6 0.6 9.500 0.6 0.6 0.6 0.6 0.6 10.000 0.7 0.7 0.7 0.7 0.7 10.500 0.7 0.8 0.8 0.8 0.8 11.000 0.8 0.9 0.9 0.9 1.0 11.500 1.0 1.1 1.3 1.6 2.0 12.000 2.4 2.5 2.5 2.6 2.6 12.500 2.6 2.7 2.7 2.7 2.8 13.000 2.8 2.8 2.8 2.8 2.9 13.500 2.9 2.9 2.9 2.9 2.9 14.000 3.0 3.0 3.0 3.0 3.0 14.500 3.0 3.0 3.0 3.1 3.1 15.000 3.1 3.1 3.1 3.1 3.1 15.500 3.1 3.1 3.1 3.2 3.2 16.000 3.2 3.2 3.2 3.2 3.2 16.500 3.2 3.2 3.2 3.2 3.2 Bentley Systems,Inc. Haestad Methods Solution Pond Pack CONNECT Edition Pre-Developed(Pre DAs).ppc Center [10.02.00.01] 6/22/2023 27 Siemon Company Drive Suite 200 W Page 5 of 21 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Time-Depth Curve Return Event: 2 years Label: Union County Storm Event: TypeII 24hr (3.6 in) Scenario: Union County- Synthetic Curve, 2 yrs CUMULATIVE RAINFALL (in) Output Time Increment = 0.100 hours Time on left represents time for first value in each row. Time Depth Depth Depth Depth Depth (hours) (in) (in) (in) (in) (in) 17.000 3.2 3.3 3.3 3.3 3.3 17.500 3.3 3.3 3.3 3.3 3.3 18.000 3.3 3.3 3.3 3.3 3.3 18.500 3.3 3.4 3.4 3.4 3.4 19.000 3.4 3.4 3.4 3.4 3.4 19.500 3.4 3.4 3.4 3.4 3.4 20.000 3.4 3.4 3.4 3.4 3.4 20.500 3.5 3.5 3.5 3.5 3.5 21.000 3.5 3.5 3.5 3.5 3.5 21.500 3.5 3.5 3.5 3.5 3.5 22.000 3.5 3.5 3.5 3.5 3.5 22.500 3.5 3.5 3.5 3.6 3.6 23.000 3.6 3.6 3.6 3.6 3.6 23.500 3.6 3.6 3.6 3.6 3.6 24.000 1 3.6 (N/A) I (N/A) I (N/A) I (N/A) Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition Pre-Developed(Pre DAs).ppc Center [10.02.00.01] 6/22/2023 27 Siemon Company Drive Suite 200 W Page 6 of 21 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Time-Depth Curve Return Event: 10 years Label: Union County Storm Event: TypeII 24hr (5.2 in) Scenario: Union County- Synthetic Curve, 10 yrs Time-Depth Curve: TypeII 24hr(5.2 in) Label TypeII 24hr(5.2 in) Start Time 0.000 hours Increment 0.100 hours End Time 24.000 hours Return Event 10 years CUMULATIVE RAINFALL (in) Output Time Increment = 0.100 hours Time on left represents time for first value in each row. Time Depth Depth Depth Depth Depth (hours) (in) (in) (in) (in) (in) 0.000 0.0 0.0 0.0 0.0 0.0 0.500 0.0 0.0 0.0 0.0 0.0 1.000 0.1 0.1 0.1 0.1 0.1 1.500 0.1 0.1 0.1 0.1 0.1 2.000 0.1 0.1 0.1 0.1 0.1 2.500 0.1 0.2 0.2 0.2 0.2 3.000 0.2 0.2 0.2 0.2 0.2 3.500 0.2 0.2 0.2 0.2 0.2 4.000 0.2 0.3 0.3 0.3 0.3 4.500 0.3 0.3 0.3 0.3 0.3 5.000 0.3 0.3 0.3 0.4 0.4 5.500 0.4 0.4 0.4 0.4 0.4 6.000 0.4 0.4 0.4 0.4 0.5 6.500 0.5 0.5 0.5 0.5 0.5 7.000 0.5 0.5 0.5 0.5 0.6 7.500 0.6 0.6 0.6 0.6 0.6 8.000 0.6 0.6 0.6 0.7 0.7 8.500 0.7 0.7 0.7 0.7 0.7 9.000 0.8 0.8 0.8 0.8 0.8 9.500 0.8 0.9 0.9 0.9 0.9 10.000 0.9 1.0 1.0 1.0 1.0 10.500 1.1 1.1 1.1 1.2 1.2 11.000 1.2 1.3 1.3 1.4 1.4 11.500 1.5 1.6 1.8 2.2 3.0 12.000 3.4 3.5 3.6 3.7 3.8 12.500 3.8 3.9 3.9 3.9 4.0 13.000 4.0 4.0 4.1 4.1 4.1 13.500 4.2 4.2 4.2 4.2 4.2 14.000 4.3 4.3 4.3 4.3 4.3 14.500 4.4 4.4 4.4 4.4 4.4 15.000 4.4 4.5 4.5 4.5 4.5 15.500 4.5 4.5 4.5 4.6 4.6 16.000 4.6 4.6 4.6 4.6 4.6 16.500 4.6 4.6 4.7 4.7 4.7 Bentley Systems,Inc. Haestad Methods Solution Pond Pack CONNECT Edition Pre-Developed(Pre DAs).ppc Center [10.02.00.01] 6/22/2023 27 Siemon Company Drive Suite 200 W Page 7 of 21 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Time-Depth Curve Return Event: 10 years Label: Union County Storm Event: TypeII 24hr (5.2 in) Scenario: Union County- Synthetic Curve, 10 yrs CUMULATIVE RAINFALL (in) Output Time Increment = 0.100 hours Time on left represents time for first value in each row. Time Depth Depth Depth Depth Depth (hours) (in) (in) (in) (in) (in) 17.000 4.7 4.7 4.7 4.7 4.7 17.500 4.7 4.8 4.8 4.8 4.8 18.000 4.8 4.8 4.8 4.8 4.8 18.500 4.8 4.8 4.9 4.9 4.9 19.000 4.9 4.9 4.9 4.9 4.9 19.500 4.9 4.9 4.9 4.9 4.9 20.000 5.0 5.0 5.0 5.0 5.0 20.500 5.0 5.0 5.0 5.0 5.0 21.000 5.0 5.0 5.0 5.0 5.0 21.500 5.0 5.1 5.1 5.1 5.1 22.000 5.1 5.1 5.1 5.1 5.1 22.500 5.1 5.1 5.1 5.1 5.1 23.000 5.1 5.1 5.2 5.2 5.2 23.500 5.2 5.2 5.2 5.2 5.2 24.000 1 5.2 (N/A) I (N/A) I (N/A) I (N/A) Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition Pre-Developed(Pre DAs).ppc Center [10.02.00.01] 6/22/2023 27 Siemon Company Drive Suite 200 W Page 8 of 21 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Time-Depth Curve Return Event: 25 years Label: Union County Storm Event: TypeII 24hr (6.2 in) Scenario: Union County- Synthetic Curve, 25 yrs Time-Depth Curve: TypeII 24hr(6.2 in) Label TypeII 24hr(6.2 in) Start Time 0.000 hours Increment 0.100 hours End Time 24.000 hours Return Event 25 years CUMULATIVE RAINFALL (in) Output Time Increment = 0.100 hours Time on left represents time for first value in each row. Time Depth Depth Depth Depth Depth (hours) (in) (in) (in) (in) (in) 0.000 0.0 0.0 0.0 0.0 0.0 0.500 0.0 0.0 0.0 0.1 0.1 1.000 0.1 0.1 0.1 0.1 0.1 1.500 0.1 0.1 0.1 0.1 0.1 2.000 0.1 0.1 0.2 0.2 0.2 2.500 0.2 0.2 0.2 0.2 0.2 3.000 0.2 0.2 0.2 0.2 0.2 3.500 0.3 0.3 0.3 0.3 0.3 4.000 0.3 0.3 0.3 0.3 0.3 4.500 0.3 0.4 0.4 0.4 0.4 5.000 0.4 0.4 0.4 0.4 0.4 5.500 0.4 0.5 0.5 0.5 0.5 6.000 0.5 0.5 0.5 0.5 0.5 6.500 0.6 0.6 0.6 0.6 0.6 7.000 0.6 0.6 0.6 0.7 0.7 7.500 0.7 0.7 0.7 0.7 0.7 8.000 0.7 0.8 0.8 0.8 0.8 8.500 0.8 0.8 0.9 0.9 0.9 9.000 0.9 0.9 1.0 1.0 1.0 9.500 1.0 1.0 1.1 1.1 1.1 10.000 1.1 1.1 1.2 1.2 1.2 10.500 1.3 1.3 1.3 1.4 1.4 11.000 1.5 1.5 1.6 1.6 1.7 11.500 1.8 1.9 2.2 2.7 3.5 12.000 4.1 4.2 4.3 4.4 4.5 12.500 4.6 4.6 4.7 4.7 4.7 13.000 4.8 4.8 4.9 4.9 4.9 13.500 5.0 5.0 5.0 5.0 5.1 14.000 5.1 5.1 5.1 5.2 5.2 14.500 5.2 5.2 5.2 5.3 5.3 15.000 5.3 5.3 5.3 5.3 5.4 15.500 5.4 5.4 5.4 5.4 5.4 16.000 5.5 5.5 5.5 5.5 5.5 16.500 5.5 5.5 5.6 5.6 5.6 Bentley Systems,Inc. Haestad Methods Solution Pond Pack CONNECT Edition Pre-Developed(Pre DAs).ppc Center [10.02.00.01] 6/22/2023 27 Siemon Company Drive Suite 200 W Page 9 of 21 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Time-Depth Curve Return Event: 25 years Label: Union County Storm Event: TypeII 24hr (6.2 in) Scenario: Union County- Synthetic Curve, 25 yrs CUMULATIVE RAINFALL (in) Output Time Increment = 0.100 hours Time on left represents time for first value in each row. Time Depth Depth Depth Depth Depth (hours) (in) (in) (in) (in) (in) 17.000 5.6 5.6 5.6 5.6 5.6 17.500 5.7 5.7 5.7 5.7 5.7 18.000 5.7 5.7 5.7 5.7 5.8 18.500 5.8 5.8 5.8 5.8 5.8 19.000 5.8 5.8 5.8 5.8 5.9 19.500 5.9 5.9 5.9 5.9 5.9 20.000 5.9 5.9 5.9 5.9 5.9 20.500 5.9 6.0 6.0 6.0 6.0 21.000 6.0 6.0 6.0 6.0 6.0 21.500 6.0 6.0 6.0 6.0 6.0 22.000 6.1 6.1 6.1 6.1 6.1 22.500 6.1 6.1 6.1 6.1 6.1 23.000 6.1 6.1 6.1 6.2 6.2 23.500 6.2 6.2 6.2 6.2 6.2 24.000 1 6.2 (N/A) I (N/A) I (N/A) I (N/A) Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition Pre-Developed(Pre DAs).ppc Center [10.02.00.01] 6/22/2023 27 Siemon Company Drive Suite 200 W Page 10 of 21 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Time-Depth Curve Return Event: 50 years Label: Union County Storm Event: TypeII 24hr (7.0 in) Scenario: Union County- Synthetic Curve, 50 yrs Time-Depth Curve: TypeII 24hr(7.0 in) Label TypeII 24hr(7.0 in) Start Time 0.000 hours Increment 0.100 hours End Time 24.000 hours Return Event 50 years CUMULATIVE RAINFALL (in) Output Time Increment = 0.100 hours Time on left represents time for first value in each row. Time Depth Depth Depth Depth Depth (hours) (in) (in) (in) (in) (in) 0.000 0.0 0.0 0.0 0.0 0.0 0.500 0.0 0.0 0.1 0.1 0.1 1.000 0.1 0.1 0.1 0.1 0.1 1.500 0.1 0.1 0.1 0.1 0.1 2.000 0.2 0.2 0.2 0.2 0.2 2.500 0.2 0.2 0.2 0.2 0.2 3.000 0.2 0.3 0.3 0.3 0.3 3.500 0.3 0.3 0.3 0.3 0.3 4.000 0.3 0.3 0.4 0.4 0.4 4.500 0.4 0.4 0.4 0.4 0.4 5.000 0.4 0.5 0.5 0.5 0.5 5.500 0.5 0.5 0.5 0.5 0.5 6.000 0.6 0.6 0.6 0.6 0.6 6.500 0.6 0.6 0.7 0.7 0.7 7.000 0.7 0.7 0.7 0.7 0.8 7.500 0.8 0.8 0.8 0.8 0.8 8.000 0.8 0.9 0.9 0.9 0.9 8.500 0.9 0.9 1.0 1.0 1.0 9.000 1.0 1.1 1.1 1.1 1.1 9.500 1.1 1.2 1.2 1.2 1.2 10.000 1.3 1.3 1.3 1.4 1.4 10.500 1.4 1.5 1.5 1.5 1.6 11.000 1.6 1.7 1.8 1.8 1.9 11.500 2.0 2.1 2.5 3.0 4.0 12.000 4.6 4.8 4.9 5.0 5.1 12.500 5.1 5.2 5.3 5.3 5.4 13.000 5.4 5.4 5.5 5.5 5.6 13.500 5.6 5.6 5.7 5.7 5.7 14.000 5.7 5.8 5.8 5.8 5.8 14.500 5.9 5.9 5.9 5.9 6.0 15.000 6.0 6.0 6.0 6.0 6.1 15.500 6.1 6.1 6.1 6.1 6.1 16.000 6.2 6.2 6.2 6.2 6.2 16.500 6.2 6.3 6.3 6.3 6.3 Bentley Systems,Inc. Haestad Methods Solution Pond Pack CONNECT Edition Pre-Developed(Pre DAs).ppc Center [10.02.00.01] 6/22/2023 27 Siemon Company Drive Suite 200 W Page 11 of 21 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Time-Depth Curve Return Event: 50 years Label: Union County Storm Event: TypeII 24hr (7.0 in) Scenario: Union County- Synthetic Curve, 50 yrs CUMULATIVE RAINFALL (in) Output Time Increment = 0.100 hours Time on left represents time for first value in each row. Time Depth Depth Depth Depth Depth (hours) (in) (in) (in) (in) (in) 17.000 6.3 6.3 6.3 6.4 6.4 17.500 6.4 6.4 6.4 6.4 6.4 18.000 6.4 6.5 6.5 6.5 6.5 18.500 6.5 6.5 6.5 6.5 6.6 19.000 6.6 6.6 6.6 6.6 6.6 19.500 6.6 6.6 6.6 6.6 6.7 20.000 6.7 6.7 6.7 6.7 6.7 20.500 6.7 6.7 6.7 6.7 6.7 21.000 6.8 6.8 6.8 6.8 6.8 21.500 6.8 6.8 6.8 6.8 6.8 22.000 6.8 6.8 6.9 6.9 6.9 22.500 6.9 6.9 6.9 6.9 6.9 23.000 6.9 6.9 6.9 6.9 7.0 23.500 7.0 7.0 7.0 7.0 7.0 24.000 1 7.0 (N/A) I (N/A) I (N/A) I (N/A) Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition Pre-Developed(Pre DAs).ppc Center [10.02.00.01] 6/22/2023 27 Siemon Company Drive Suite 200 W Page 12 of 21 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Time-Depth Curve Return Event: 100 years Label: Union County Storm Event: TypeII 24hr (7.9 in) Scenario: Union County- Synthetic Curve, 100 yrs Time-Depth Curve: TypeII 24hr(7.9 in) Label TypeII 24hr(7.9 in) Start Time 0.000 hours Increment 0.100 hours End Time 24.000 hours Return Event 100 years CUMULATIVE RAINFALL (in) Output Time Increment = 0.100 hours Time on left represents time for first value in each row. Time Depth Depth Depth Depth Depth (hours) (in) (in) (in) (in) (in) 0.000 0.0 0.0 0.0 0.0 0.0 0.500 0.0 0.0 0.1 0.1 0.1 1.000 0.1 0.1 0.1 0.1 0.1 1.500 0.1 0.1 0.1 0.2 0.2 2.000 0.2 0.2 0.2 0.2 0.2 2.500 0.2 0.2 0.2 0.3 0.3 3.000 0.3 0.3 0.3 0.3 0.3 3.500 0.3 0.3 0.3 0.4 0.4 4.000 0.4 0.4 0.4 0.4 0.4 4.500 0.4 0.4 0.5 0.5 0.5 5.000 0.5 0.5 0.5 0.5 0.5 5.500 0.6 0.6 0.6 0.6 0.6 6.000 0.6 0.6 0.7 0.7 0.7 6.500 0.7 0.7 0.7 0.8 0.8 7.000 0.8 0.8 0.8 0.8 0.8 7.500 0.9 0.9 0.9 0.9 0.9 8.000 0.9 1.0 1.0 1.0 1.0 8.500 1.0 1.1 1.1 1.1 1.1 9.000 1.2 1.2 1.2 1.2 1.3 9.500 1.3 1.3 1.3 1.4 1.4 10.000 1.4 1.5 1.5 1.5 1.6 10.500 1.6 1.7 1.7 1.7 1.8 11.000 1.9 1.9 2.0 2.1 2.1 11.500 2.2 2.4 2.8 3.4 4.5 12.000 5.2 5.4 5.5 5.6 5.7 12.500 5.8 5.9 5.9 6.0 6.0 13.000 6.1 6.1 6.2 6.2 6.3 13.500 6.3 6.3 6.4 6.4 6.4 14.000 6.5 6.5 6.5 6.6 6.6 14.500 6.6 6.6 6.7 6.7 6.7 15.000 6.7 6.8 6.8 6.8 6.8 15.500 6.9 6.9 6.9 6.9 6.9 16.000 7.0 7.0 7.0 7.0 7.0 16.500 7.0 7.1 7.1 7.1 7.1 Bentley Systems,Inc. Haestad Methods Solution Pond Pack CONNECT Edition Pre-Developed(Pre DAs).ppc Center [10.02.00.01] 6/22/2023 27 Siemon Company Drive Suite 200 W Page 13 of 21 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Time-Depth Curve Return Event: 100 years Label: Union County Storm Event: TypeII 24hr (7.9 in) Scenario: Union County- Synthetic Curve, 100 yrs CUMULATIVE RAINFALL (in) Output Time Increment = 0.100 hours Time on left represents time for first value in each row. Time Depth Depth Depth Depth Depth (hours) (in) (in) (in) (in) (in) 17.000 7.1 7.1 7.2 7.2 7.2 17.500 7.2 7.2 7.2 7.2 7.3 18.000 7.3 7.3 7.3 7.3 7.3 18.500 7.3 7.4 7.4 7.4 7.4 19.000 7.4 7.4 7.4 7.4 7.5 19.500 7.5 7.5 7.5 7.5 7.5 20.000 7.5 7.5 7.5 7.6 7.6 20.500 7.6 7.6 7.6 7.6 7.6 21.000 7.6 7.6 7.6 7.7 7.7 21.500 7.7 7.7 7.7 7.7 7.7 22.000 7.7 7.7 7.7 7.7 7.8 22.500 7.8 7.8 7.8 7.8 7.8 23.000 7.8 7.8 7.8 7.8 7.8 23.500 7.9 7.9 7.9 7.9 7.9 24.000 1 7.9 (N/A) I (N/A) I (N/A) I (N/A) Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition Pre-Developed(Pre DAs).ppc Center [10.02.00.01] 6/22/2023 27 Siemon Company Drive Suite 200 W Page 14 of 21 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Runoff CN-Area Return Event: 2 years Label: PRE-AREA-10 Storm Event: TypeII 24hr (3.6 in) Scenario: Union County - Synthetic Curve, 2 yrs Runoff Curve Number Data Soil/Surface Description CN Area C UC Adjusted CN (acres) Woods-good -Soil B 55.000 11.980 0.0 0.0 55.000 COMPOSITE AREA&WEIGHTED CN---> (N/A) 11.980 (N/A) (N/A) 55.000 Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition Pre-Developed(Pre DAs).ppc Center [10.02.00.01] 6/22/2023 27 Siemon Company Drive Suite 200 W Page 15 of 21 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Runoff CN-Area Return Event: 2 years Label: PRE-AREA-11 Storm Event: TypeII 24hr (3.6 in) Scenario: Union County - Synthetic Curve, 2 yrs Runoff Curve Number Data Soil/Surface Description CN Area C UC Adjusted CN (acres) Woods-good -Soil B 55.000 7.490 0.0 0.0 55.000 COMPOSITE AREA&WEIGHTED CN---> (N/A) 7.490 (N/A) (N/A) 55.000 Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition Pre-Developed(Pre DAs).ppc Center [10.02.00.01] 6/22/2023 27 Siemon Company Drive Suite 200 W Page 16 of 21 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Runoff CN-Area Return Event: 2 years Label: PRE-AREA-12 Storm Event: TypeII 24hr (3.6 in) Scenario: Union County- Synthetic Curve, 2 yrs Runoff Curve Number Data Soil/Surface Description CN Area C UC Adjusted CN (acres) Woods-good -Soil B 55.000 8.297 0.0 0.0 55.000 COMPOSITE AREA&WEIGHTED CN---> (N/A) 8.297 (N/A) (N/A) 55.000 Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition Pre-Developed(Pre DAs).ppc Center [10.02.00.01] 6/22/2023 27 Siemon Company Drive Suite 200 W Page 17 of 21 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Runoff CN-Area Return Event: 2 years Label: PRE-AREA-7 Storm Event: TypeII 24hr (3.6 in) Scenario: Union County - Synthetic Curve, 2 yrs Runoff Curve Number Data Soil/Surface Description CN Area C UC Adjusted CN (acres) (%) (%) Woods-good -Soil B 55.000 12.190 0.0 0.0 55.000 Woods-good -Soil A 30.000 2.780 0.0 0.0 30.000 COMPOSITE AREA&WEIGHTED CN---> (N/A) 14.970 (N/A) (N/A) 50.357 Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition Pre-Developed(Pre DAs).ppc Center [10.02.00.01] 6/22/2023 27 Siemon Company Drive Suite 200 W Page 18 of 21 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Runoff CN-Area Return Event: 2 years Label: PRE-AREA-8 Storm Event: TypeII 24hr (3.6 in) Scenario: Union County - Synthetic Curve, 2 yrs Runoff Curve Number Data Soil/Surface Description CN Area C UC Adjusted CN (acres) Woods-good -Soil B 55.000 16.370 0.0 0.0 55.000 COMPOSITE AREA&WEIGHTED CN---> (N/A) 16.370 (N/A) (N/A) 55.000 Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition Pre-Developed(Pre DAs).ppc Center [10.02.00.01] 6/22/2023 27 Siemon Company Drive Suite 200 W Page 19 of 21 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Runoff CN-Area Return Event: 2 years Label: PRE-AREA-9 Storm Event: TypeII 24hr (3.6 in) Scenario: Union County - Synthetic Curve, 2 yrs Runoff Curve Number Data Soil/Surface Description CN Area C UC Adjusted CN (acres) (%) (%) Woods-good -Soil B 55.000 14.790 0.0 0.0 55.000 Woods-good -Soil A 30.000 2.630 0.0 0.0 30.000 COMPOSITE AREA&WEIGHTED CN---> (N/A) 17.420 (N/A) (N/A) 51.226 Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition Pre-Developed(Pre DAs).ppc Center [10.02.00.01] 6/22/2023 27 Siemon Company Drive Suite 200 W Page 20 of 21 Watertown,CT 06795 USA +1-203-755-1666 Index M Master Network Summary...1, 2,3,4 P PRE-AREA-10(Runoff CN-Area, 2 years(Union County-Synthetic Curve, 2 yrs))...15 PRE-AREA-11 (Runoff CN-Area, 2 years(Union County-Synthetic Curve, 2 yrs))...16 PRE-AREA-12(Runoff CN-Area, 2 years(Union County-Synthetic Curve, 2 yrs))...17 PRE-AREA-7(Runoff CN-Area, 2 years(Union County-Synthetic Curve, 2 yrs))...18 PRE-AREA-8(Runoff CN-Area, 2 years(Union County-Synthetic Curve, 2 yrs))...19 PRE-AREA-9(Runoff CN-Area, 2 years(Union County-Synthetic Curve, 2 yrs))...20 U Union County(Time-Depth Curve, 10 years(Union County-Synthetic Curve, 10 yrs))...7,8 Union County(Time-Depth Curve, 100 years(Union County-Synthetic Curve, 100 yrs))...13, 14 Union County(Time-Depth Curve, 2 years(Union County-Synthetic Curve, 2 yrs))...5,6 Union County(Time-Depth Curve, 25 years(Union County-Synthetic Curve, 25 yrs))...9, 10 Union County(Time-Depth Curve, 50 years(Union County-Synthetic Curve, 50 yrs))...11, 12 Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition Pre-Developed(Pre DAs).ppc Center [10.02.00.01] 6/22/2023 27 Siemon Company Drive Suite 200 W Page 21 of 21 Watertown,CT 06795 USA +1-203-755-1666 Post Developed Calculations: / JJCu1li.Vesign. ET 223 NORTH GRAHAM STREET \\ ///// I l // // - _ i l/ / \ ~ \\ \`- \ \ j f \ C ` 1 \✓i i�i f f •5/ ^\ \\( \ f/JG j�( �-1\\ \ l ( / CHARLOTTE.NC 28202 / / ✓i I J \ /r j\ l� vVo /1 I 1 !�)/J f / / 704.333.0325 WWW.LANDDESIGN.COM -/„l///// ///ji _=__ I / \ `\� � �� � I �(I11�\ \ \ � l//// ✓\��/ �\ \��i��i/��_�\\`�)\c III /r/�( / / _---_ _G/iiii/i/=_ / / / - ' \ �► s \ \ �r ) I l 1 / /� �/� \ \�t�\ ( rS \\\\ `�\\)Ilr(//� / ( / / / / /!/// �/�_4_--; / / \ -�\ `\- \ AREA= 16.37AC \\ /\ /// ✓ \ I e\ \ \/ / / / // / T 7 `E%IST.STREAM/ _TYP))) I l III 1 \\\ \ \ \\✓ / \ \ / /// / // r ) �//// � f ASV �� �/ J J ) 1 I zss I /�/ .<� c [ / �� V ��♦ /// // /vvv A // POINT DEAN - \\ ` / 1 �♦ / / /// \\ \ / / v v � / A A I " sas \1A�VA��I/ s 1 v / ♦ / // vv v ExISTINGRnv ,�fll� /X/ / zsa \ ! ,,.,, t ,ov 1 -�// 1 1) 1 as � �� ( �vA ` .,V a ,// ♦♦♦ , / v A\Y ' / 11 I ) "'�I / �3 S T ) \,/ / J s7 I °.o , "-\., ♦ / \\ // 41 / 4 /�/1/ Sic l/����/� / _ - tr �Jiv / / \,��/ /1� t � ♦♦ \ / // /�f// //J '/ram % / / II / BMP1z /° r f l�4 ♦♦ � 111 / AREA= 361�1 (( ® �'� \, l�l ) 1 ( 8.29 AC / t' /;�\� /r/ /.-.ry ♦♦ // / \ \ \\ / r PROPERTY �- �/ / I BOUND ARY(TYP) \ l ` I h zso ; lzas 7 \ /\ \)I S� ~T' \ \ -1 .�50,..........•I''',EXIST.STREAM\ /1() \t t \ 1 � ) � / ) / I � p0 � �i/ �/ \ //." , ' _ 1 :`F''• °\ \ \ � .szo \\- 3sa•,, � \ 1 ;v:• '•.o; \VAS �lV v ���l VIA l) I vA i VA \ / / �� �6� Jl SIlV l�/ m� �``1I// I _ _ f�(1y / Jf t t\ \\s\ )�rt)\ 2 I?\\( /\h l S 1 \ ( // 28] u \1 I / / f BYPASS \ I 1 CORPORATE _ f/ `Pv / / 1 DIVERSION S f 1 17A� f/r { /rJ \ / / : r _$" l / 2ao s " �. 1 A ]A4 l I �/� I ( , 11 DITCHAREA= DEAL \ 11( °11 j ( /�/ / / / !// / ♦/ -, f / z79 " ✓V ✓'° -: (�✓ I/ v/ s2o ///� l A T3ss I I� 4.93AC- 1 - 1 I 3�'•. .'$�` 1 t ) -' / / r / =r+- ' r 655 r I 6^° I 1 I '',.gyp•. :'��c Ir i ) 1 1\ JSV\ ( 1 t ' r\ � � �� / , � _ � zees / i\ �ti ) � ,�,�J - - � C /\ 1\-k---��--- I 1� T•. :oy`,, X...CAR�,. S r/ f RITCHTO:1 LINED WITH - - 1 .•p ES /''': � ) ( \ PROPOSED PERMANENT _ CA i mP.) 2:1 SIDE SLOPES BMP-7 L- - Y A i / , /_" ( 1 1 (f 4 I 1` a { AREA v zzs ) T°I �0� v z]z I� I A 1 1 35s„ a]° - -- ■ V 1 i on]s V _ fl)il / Ml\1 \ 14.23 AC y/y� ' l � ( (( lJ ��=/ ' i 1 A (1 t� d� �/���v.� � ( ��r l m %a" .�.: z73 � 1 2- t` sss 1�A \l A A� �1� ) tl 3sa v°�, //� � �' / / � I � ;T•. •'2, AM, -- %;p':emc TEe:•X-: �I./ z]a S � l r 1 1 /s 37z In•,. -�-- � - 1 02/16/24 665/ �'S k\ 220 ♦ �� \ - 234 ! l \� \ �o '( 360 56 / THE PRESERVE t � 215 / i 219 ♦ \-� ` 84 0.. \` 235 � 665 � 268 I 1 13 \\\\ \ \ r i�,Y \ 6h v 352� '. I -•1_/ �•_ - t, _-�- -' 11 � 2�6 �� ♦ � .. v °' za]� /�s°..tea/ A �' S � °I` A1A A t � �l I \)Il1'l s .. r/36a � r� I 3]s �� _->- � I I � AT FOREST 1 1 CREEK- PHASE 2 � � 48 362 I a ( a]6 1\ WAXHAW VENTURES LLC 260 5615 POTTER RD ,, � • e .°es _aa: - 2z] i l �, ( 4 � 610 239 ". A A z61 v I ' 'v.�/ � / 363 � -�_ -- " 1 - - - B MATTHE S, C28104 W N zsa \ V 1 . ss � It l ��J 11 sso 1 � J / I I t I � ✓1 / / z2z I z23v - � V� ! m� � ° V A A ,y V�a16 0 A - '/� - ( "Ac - l \- _- \ -DESIGN rnoJ.a 1021143 Ir// r/ REVISION/ISSUANCE _-- 1 NO. DESCRIPTION DATE ! ----��-� �� �/ " �f' 1J A \ i 253 l J / J��//' �\ 1 BMP-11 o ly M6 v --k l 1 1ST-CDSUBMITTAL 10/14/22 1 / 1/ / \�� `o\ / z0.p 3 / ( POINT OF ANALYSIS i / AREA= 3 f I I ro I \°' 381 1 S 1 ."� 7.49 AC a \ 2 ND-CD SUBMITTAL 02/10/23 � ( 1 o Il( \ \il I 670/ '? s //� / // I � / � 338 ♦11 \ d _ -___�_ 3 3RD-CDSUBMITTAL 04/28/23 .r - `'^- � \ \1 \ ( � � _ /, 32z r/�/jT 1 7 1 Ill 3aa \�::. \ `-- �► \_ \� I ,i* 6,°'' / - (/J •_ (' 1 ) y \ I __-- 4 4TH-CD SUBMITTAL O6/09/23 30'STREAM BUFFER:1 \ \ (TVP) _ -ois V AA V IV A 1 \ _ _ rJ l l (/// (J -.�- .'b�°(� I 1 ✓ 3a] PLAN LEGEND 5 5TH-CD SUBMITTAL 09/29/23 �; \ ( \ 1332 343 1 Y S 5o'STREAM BUFFER \ 1 6 6TH-CDSUBMITTAL 11/03/23 PROP.STORM DRAINAGE ® �.-�"� (TYP) \`\ 7(\ \!\i \\\ \\ '� \ r 326 / / )l,l)\ I IJ; t \ \s� 1 " u` \./mot+ -_ / / - 1 \ 'J Ym�' 133 \ }42 \ BMP-11 - 7 7TH-CD SUBMITTAL 12/05/23 BASIN DRAINAGE BOUNDARY ------- I�^ s 1 s� \ \ �� EX.WETLAND(TYP) PROP.STORM DRAINAGE MANHOLE PROP.CATCH BASIN /l�r( `\ \ �y, ::\\ SEE SHEET C414 FOR CONTINUATION PROP.WATER MAIN W NOTES: 1. SEE SHEET C413 FOR ADDITIONAL NOTES AND DETAILS. PROP.SANITARY SEWER 2. SEE SHEETS C401 TO C405 FOR STORM SEWER GRADES AND INVERT ELEVATIONS. DRAWN BY: STB 3. SEE SHEETS C406 TO C411 FOR WET POND DETAILS. PROP.SANITARY SEWER MANHOLE 4. SEE GRADING PLANS CHAPTER 5 FOR SITE GRADING INFORMATION. CHECKED BY FJM • s. CATCH BASIN RIM ELEVATIONS ARE GIVEN TO THE EDGE OF ASPHALT,YARD INLETS AT BMP-7 BMP-8 BMP-12 Scare No- PROP.STORM DRAINAGE EASEMENT -soc-soc- FINISHED GRADE. Elevation Post PREQ Elevation Post PRE Elevation PostQ PRE 6. RIM ELEVATIONS GIVEN ON THESE PLANS ARE APPROXIMATE AND ARE FOR EX.SANITARY SEWER -ss-BE INFORMATIONAL PURPOSES ONLY.ACTUAL RIM ELEVATIONS SHALL BE DETERMINED BY WQ 645.17 0.24 WQ 623.68 0.29 0 WQ 615.58 0.16 CONTRACTOR AND ADJUSTED TO MATCH FIELD CONDITIONS. VERT: N/A ]. APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES 2yY 647.03 0.92 1.06 2yY 625.24 3.75 4.39 2yf 616.55 1.82 1.93 HORZ: 1'=100' EX.EASEMENT - - 8. IN ORDER TO ENSURE PROPER DRAINAGE,KEEP A MINIMUM OF 0.50%SLOPE ON THE CURB. 10yr 647.85 8.32 9.48 10yr 626.70 15.94 18.62 10yr 617.88 7.98 8.37 EX.RIGHT OF WAY RW 9. CURB AND GUTTER SHOWN ON PLANS MAY BE ADJUSTED BASED UPON FIELD STAKING BY 25� 648.57 16.00 17.46 25� 627.59 27.49 30.26 25 f 618.72 13.61 13.63 0 so, 100' 200' INSPECTOR/ENGINEER.ASSOCIATED STORM DRAINAGE MAY ALSO REQUIRE MODIFICATION Y Y Y EX.STORM DRAINAGE BASED UPON FIELD CONDITIONS. 50yr 649.08 33.69 24.99 50yr 628.22 40.99 40.58 50yr 619.31 21.19 18.31 SHEErTITBE 10. THE PURPOSE OF THE STORM DRAINAGE EASEMENT IS TO PROVIDE STORM WATER EX.WATER MAIN -w-w-w- CONVEYANCE AND ANY STRUCTURES AND/OR OBSTRUCTION TO STORM WATER FLOW IS 100yr 649.45 66.22 34.36 100yr 628.89 56.07 52.96 100yr 619.77 36.94 24.00 POST-DEVELOPMENT PROHIBITED. WETLAND NOTES: EX.OVERHEAD ELECTRIC of of 11. ALL DESIGN AND CONSTRUCTION METHODS SHALL BE DONE IN ACCORDANCE WITH TOWN DRAINAGE AREAS EXTERIOR PERIMETER _7A OF WAXHAW AND NCDOT STANDARDS AND SPECIFICATIONS. 1. TOTAL WETLAND DELINEATION DETERMINED BY GPI SURVEY: TREE SAVE/VEGETATIVE BUFFER 12. ALL YARD INLETS SHALL BE DROP INLET TYPE-SEE DETAILS. 0.39 ACRES.PSL:SETH MARTIN SHED NUMBER W100 8:01AM °Wo�US �L�p2111°,,,4�°MU%INT ION�l,PH.SIMII PL�OST-0 I aNa le B ORIGIN-SHeeTS-1-1°B C413 SEE SHEET C413 FOR CONTINUATION LandDesign. yI i \ zza n NORTH RAHAM- \ ` I•!\ \`` \ I )o/ ! / � / �v � f' 275 � i \� \ 1 ) Q r' � .- � 1 223 , STREET CHARLOTTE NC 704.333.0325 - sS3. WWW.LANDDESIGN.COM BMP 9 233 , \ 288 \'\/ J( 1 \ \ \V.\\'- \ ) /1 ^ / _ r 1 ��f �111 Elevation Post4 PREQ 219 \ 1 #o ` \•\ 235 665 or\ 268 WQ 655.655.68 0.29 2yr 617.94 1.24 1.64 t0yr 659.32 7.78 11.94 243 :_ oa. 660 , •-"g\\ 16 \1 \\\ 1 I I l 860 r 1 t 351 1 r / ~' 1 25yr 660.23 14.75 21.58 �. 11 1 50yr 660.87 21.94 30.33 �"o \ \\ 260 I I l\ 1 ?17�/(1 I ( 3]6 1 100yr 661.42 43.19 40.99 z42 I A 2a,BB � ez�\ -�- _ 'C 3MP-10 228 1 \ I r - \\\ Z •I ' I l 1 Elevation Post Q PRE Q wQ 656.23 azs z j v �-<V ) AA l� 1 �l / f ,I . f - \ 244 \ 5101 A A m \1 \�) ,.ss _ 3] s°ol- <°I / ( / = I 2yr 657.98 1.71 2.50 o \\° I {I II p % \a ( / zas \ \� \1 s� \ zss \ \\ll\)� I1 t 1 ( - _ �° 'l s \ /L % _a J 11 1 yr 659.08 8.18 10.96 -" -k- 50 25yrr 660.42 18.15 24.04 659.85 1178 17.90 J y v ) r // l I - I .I ( \ / \ ' / �$ �''\ \ \ \ f /I J -^ l l/ / 1•/ // h"+ ;: / -.a 1 \ 1 1 100yr 660.80 47.31 31.60 / / 249POINT OF ANALYSIS \�Q _- r'I/ // / '> / ' C •$ / \ \ f / 31a p/ I / J 1 / �1 380 - - BMP-11 �\ ..� \ Elevation Post PRE y v v-`- / �__ t l (�� 252 � C J /�\ a 9/ ✓' I I /% � 1 W q 634.54 0.13 2yr 635.89 1.45 1.74 / 1� 10 yr r 637. 11. 1229 22 6.55 7.55 nB°�n\ "\ \\ �(( r \\ \ •I, a �. / ./ � 321/ ( r/, �/ %-' /6'S �/ II I I/ I 336 � 1 � � _� � _- _�-� 638.09 13 \�1\ \ 1 t 1 \ \\ \ -- // - r/ ! \1 N f > > 3a] 1 �-*_-�1�- 1 so r 638.60 z4.n 16.46 sus\\\ / 4 3z/ - / G-' /.y/( /--� ''1' of}I�I h\� 1 �' 1 -1 ♦( 1 100yr 638.89 43.11 21.50 j 11-., '� \\ \ \\\ ,{\ \ \ \ \ �o r/ �� /V' /J//.✓� \\\\ �\ II.'.II \ 332\ � 3a3 I�F _ �_/ '\�o� ^^\\\ \\\\\\ \2 \�l \\\� � 1oa° 5/ ��r /1 r /////�/./,y -�\tit\ •o �y�/ (I t k �� s3ae � s� \I ,�� --J ❑ 1 \ l \ \� /J 327 / / ) I /•�-� ! \ t I 33\ 1 so 2 `'v\ - - NOTES: \ 1 \ \ i I I s�o �m , \ BMP-11 r J ^ _° \ 1\\' l\ 111 \ \ t �p 's S „� 1 1\ ` \ 384` OFFSITE �_ - 1 SEE SHEET C413 FOR ADDITIONAL NOTES AND DETAILS. 1 / °` S,y,H so 339 63y, I SEE SHEETS C401 TO C405 FOR STORM SEWER GRADES AND INVERT ELEVATIONS.ARE EAL \ E%.WETLAND(TYP) •\ ` l \ ` \ / r" ( A= �� - 3. SEE SHEETS C406 TO C411 FOR WET POND DETAILS. s '- \\ t\ !\ 341 / - 0.60 AC .o'� -_- \ 4. SEE GRADING PLANS CHAPTER 5 FOR SITE GRADING INFORMATION. J � e>o\ \\\ 1 \ / / _i`/ /� J \ 1• \ �{ e \ S- ) 0 0 - -'- _ 1 S. CATCH BASIN RIM ELEVATIONS ARE GIVEN TO THE EDGE OF ASPHALT YARD INLETS AT f f r _ ,] / , EX.WETLAND(TYP) /' /� �// _ \\\ �i C `J 340 1! \-�- FINISHED GRADE `�9F SI(�`N'�". \ $ ! I L rl ,"-,•• \\� ) ' \\\\ \ 1 _ o - ♦7 8. INFORMATIONALRIM ELEVATIONS GIVEN ON THESE0 LY PLAINS ACTUAL RIM ELEVATIONS HALLND BE FOR '.� \ /)I / \ \ .a r l I }(// T- T /- : "'A` -- - \ i� \•1\'1 1\ i% N o _ - ♦�� , INFORMATIONAL PURPOSES ONLY.ACTUAL RIM ELEVATIONS SHALL BE DETERMINED BY �) 4q ° / l ...:.. \ ( \�\\ \ �' ¢n.o°✓a° CONTRACTOR AND ADJUSTED TO MATCH FIELD CONDITIONS. \\ I �-!I / Jt// /1 /() � -L-�\ •'•" f # J �{•, r^• � :+b�••""" s`- � I \ \ � yq% "-� \ 1 _ 7. APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES = � CORPORATE > 1 ( 1 I f •f.:::i L,/� I BMP-9 p ° I � I\ \L�"••'�••.••'• � � � y° \ ~\ \ _ 8. INORDERTOENSUREPROPERDRAINAGE,KEEPAMINIMUMOFO.SO�SLOPEONTHECURB. //I Ili" /J 1(J 7 �/ sso �\\ Y��: e AREA= 1 s°r° ' _ = SEAL J 1 40 I\ 9. CURB AND GUTTER SHOWN O PLANS MAY M ADJUSTED BABEL UPON FIELD STAKING 18.63'4O I �ew. �^ j\�-= D STORM DRAINAGE MAY ALSO REQUIRE MODIFICATION\ - ^ - -- INSPECTOR/ENGINEER.ASSOCIATE %'Z`• ,$ BASED UPON FIELD CONDITIONS. � 'l 0 10. THE PURPOSE OF THE STORM DRAINAGE EASEMENT IS TO PROVIDE STORM WATER i�TH"'••"" Li6/0^r `==1 \ \�\ \ '�K/ r o°u_ I \ \ 4 \�IS\ \ PROCONVIBIANCEAND ANY STRUCTURES AND/OR OBSTRUCTION TO STORM WATER FLOW IS l'� PROHIBITED. v JL / \ ti Q` 11. ALL DESIGN AND CONSTRUCTION METHODS SHALL BE DONE IN ACCORDANCE WITH TOWN OF WAXIHAW AND/� 40] /D/ \J`\ \ fr\m\ sq•- 56+; 4 ) Y (I \ 11 - 12. ALL YARD INLETS SHALL TBE DROP RIN ET TYPE-SEE DETAILS.S. CA _ o r 7 0 lkL fy u�I�VAvwv _ `/a�� .t-1 ('• `= �VI '/4 1 / � f}J\1 / � _aaz \-' 46, � 1 \ y- y1 r J ��� .I ( Ex.WETLAND(TYP) :--���'�' \ / ml l r�� 5 s �./ _ --- ,;Yjr'•�...�CMp�.�' l,..{ J 5 - `mil I \( I , ( \ k°":°•:.�� I / ) o S ' ' / / 1 f f - 1 \ > 1_ �- V r , \ ::.:.;.:•-::': 'i- ,>-� Il' 1--I 02/16/24 f l \J � ,437 ',\ \ l t(1\�1 1 1 0 ll � I \410 1 \I � ) :{:;:::'•::•:�: / \ /391 \ 1 !( / J / °o �ti� 1 4aa 1 4 _ 1 l / J !• ;'••. r•" - -�, --'_ _ THE PRESERVE - [ _ a v vv�vv n / yam AT FOREST \\\` �- CREEK- PHASE 2 a vAAA�roF�ANALYssv� -,3% l- � \r �s/ ,s% s>o - t 1-}-✓-It�- WAXHAW VENTURES LLC 12.04 / e e^ ° \ \ \ / I _ 5615 POTTER RD AC �� - 1 \ 1 \ \ �\ l� � J 1 l •: \ �393 � 1`�\� �-I-I�- MATTHEWS,NC 28104 j* r 1 - .,`r f/ 1 `ti\ 41a �syz BMP-10 , / 700 r p 426 ) r) / ��h \/ EX.WETLAND(TYP) } �/� ! 397 �/ _ 667 \ � ) t OFFSITE , AREA= Iw 434 438 437 / ) / //�J%(//`/ •°•'\ - 1 �� / _ \,J I ) 5.99 AC / 705 /'�° a25/ /J _ / 4as 1. / �1 1/1 ////� '- /'- -v �'��A- w,00EB°H PBo,.b /)ILLve.r / v 1 1021143 / ) 1 // I > _ o \ ( / O p�Jo-ryy m,/ / =f Ss ExlsT.sTREAM Ic a '�/ ♦- __�- REVISION/ISSUANCE aza 1 sco ♦�_ A I A J> NO. DESCRIPTION DATE 30'ST r--- 1 1ST-CD SUBMITTAL 10/14/22 70 \ \ �^4) �`/✓) ^ /'� 1 � / ( 1 Il��) f /��" J REAM BUFFERS \ \ / \�/ /// / - \\V vry/�/ > JA1 I/// J // r ♦[[ ((� ///'////' 2 ND-CD SUBMITTAL 02/10/23 \\\ a23�'-' - / 1 418 1 ) rC/ l f r/J/ Jr J 7 ) 1 ` f �r"- ��L\ / / ( X ---/ , 3 3RD-CD SUBMITTAL 04/28/23 j\\l` /.- /� 420 419 1 L II..1..-\.. / J ` \ 50'STREAMBUFFER / f /r /// j/ 1 ♦ C¢ \�t /'r I I ( /' YP) r1 s BMP-9 \\\ r T 422 ��6s,az, III / J \ l / ^/ /Jr 1 r r / / - y♦J - -__ \i /�v$ I I /♦ / \ OFFSITE -F• / / , /f/ - / 4 4TH-CD SUBMITTAL 06/09/23 AREA= \ \ \ n-_-L}// _. rrJ/)1J //I )III\ J./ J // / ! /Jj J fr ) } / J/i/// �/ 1 /♦ / % PLAN LEGEND 3.01 AC /J/ �/ J// �'%�/ / ///� \\\� / l l ♦�/ 1/� 5 5TH-CD SUBMITTAL 09/29/23 ---- \ / zza �� '^ �- l / / �/ / /// ( / C_°l 1n/ / / // /// / I//I r/ // / / '♦ \ / / / / / ////J�_'_ 6 6TH-CD SUBMITTAL 11/03/23 PROP.STORM DRAINAGE ® \\ \\ vti�l c <+ I; // (r r Jj \ r///r///ram!/11{Z l)/J��1 f/I )/� �\��////III( // I IIIIIII l it l i l / / / /// ♦ - \ \y-i/\/�/ / // / • -2g _\ r=J �-t�/ 1 C\\ \ ) �\I ol�j t\N II 1 �JI / /r///1/r/f�/g/�// /�/// /// \J/ //)�_\\��/l iI(Il I II1/Iv l///-����_/_I-/I II III IIIII I I I I I II�I I I I I I I 1 I I 7 7TH-CD SUBMITTAL 12/05/23 BASIN DRAINAGE BOUNDARY -------- /, ./y \UA// / /411, PROP.STORM DAINAGE MANHOLE J / '/// / 4� PROP.CATCH BASIN ■ - 00R \ V v S fi//i/f: m^//// v X IIIIII �ll II I / ♦ _ / / I // PROP.WATER MAIN W -soe- ., //♦ -- _ PROP.SANITARY SEWER ��' / D RAWN BY: sTB , \ CHECKED BY FJM PROP.SANITARY SEWER MANHOLE "♦�0.� I oA No- PROP.STORM DRAINAGE EASEMENT � - - / EX.SANITARY SEWER - ss -ss - +/ \ \ \ \ \ \ \ \ I I I I I I II l/llllllllullllllll/III //rl \ i %/ /% �\\\�\� I \\ \ \ I 1 I / \\\\\ \\\\\\\\\ \\ \\ /-/, - / I \ \\ \\\ \ \ / / / / / VERT: N/A ///��/ //// -/ I i' / I\\\\\\\\\\\\ \\\ \I III // / / // / ♦ / HORZ: 1'=100' EX.EASEMENT EX.RIGHT OF WAY RNJ- \ 0 so, 100' 200' EX.STORM DRAINAGE \ \ \ SHEET TITRE EX.WATER MAIN -w-w-w- \ \ \ WETLAND NOTES: POST-DEVELOPMENT EX.OVERHEAD ELECTRIC of of \ \ \ DRAINAGE AREAS EXTERIOR PERIMETER 1. TOTAL WETLAND DELINEATION DETERMINED BY GPI SURVEY: TREE SAVE/VEGETATIVE BUFFER 0.39 ACRES.PSL:SETH MARTIN SHEET NUMBER C414 -a,.,,,a- Mao°UBry E�L�p21+102114�oocUMENTaTIoN�o,EHasE�„�EL�°sT-0�o�NaBE�m„0 °HIGIH-SH-B-1136 BMP-7 Water Quality Calculations: BMP-7 STAGE STORAGE CALCULATION Area Calculation-Forebay Area Volume(ac-ft) Volume Contour sq.ft AC Inc Accum. cu.ft 640 2984 0.069 0.0000 0.0000 0 641 3218 0.074 0.0712 0.0712 3100 642 3460 0.079 0.0766 0.1478 6439 643 3708 0.085 0.0823 0.2301 10022 643.5 3834 0.088 0.0433 0.2734 11907 644 3962 0.091 0.0447 0.3181 13856 Area Calculation-Main Pond Area Volume(ac-ft) Volume Contour sq.ft AC Inc Accum. cu.ft 640 15617 0.359 0.0000 0.0000 0 641 16710 0.384 0.3710 0.3710 16160 642 17817 0.409 0.3962 0.7672 33421 643 18941 0.435 0.4219 1.1891 51797 643.5 19510 0.448 0.2207 1.4098 61409 644 20972 0.481 0.2323 1.6421 71528 Ave.Main Pool Depth 3.41 Volume Calculation-Permanent Pool Area Volume(ac-ft) Volume Contour sq.ft AC Inc Accum. cu.ft 640 18601 0.427 0.0000 0.0000 0 641 19928 0.457 0.4422 0.4422 19261 642 21277 0.488 0.4729 0.9150 39860 643 22649 0.520 0.5041 1.4192 61819 643.5 23344 0.536 0.2640 1.6831 73317 644 24934 0.572 0.2770 1.9601 85384 Ave.Permanent Pool Depth 3.42 Volume Calculation-Temp Pool Area Volume(ac-ft) Volume Contour sq.ft AC Inc Accum. cu.ft 644 24934 0.572 0.0000 0.0000 0 644.5 26555 0.610 0.2955 0.2955 12870 645 27453 0.630 0.3099 0.6054 26372 646 28992 0.666 0.6478 1.2532 54591 647 30280 0.695 0.6803 1.9335 84224 648 31594 0.725 0.7102 2.6437 115159 649 32929 0.756 0.7406 3.3843 147418 650 34290 0.787 0.7715 4.1558 1 181025 Project Name: Preserve at Forest Creek- Phase 2 (BMP-7) Project Number: 1021143 Design Requirements: 85% TSS, 70% TP Given Information: Land Use: Residential Drainage Area to Facility(Acres): 14.23 Meck. County(Minimum 10 Ac. Less than 10 Ac requires water balance computations) Impervious Area (Acres): 10.07 Percent Impervious: 70.8% Soil Type: AeB, CeB2, CeC2 Soil Group: A, B Curve Number(CN) Pre: 49 Curve Number(CN) Post: 87 Time of Concentration Pre (hour): 0.298 Time of Concentration Post (hour): 0.0833 Design Storm Rainfall Depth (in): 1.0 (Typically 1") Detention Time (Day): 2 Meck. County: 4 days - 85% TSS &70% TP (Optimal Efficiency) 2 days -60% TSS &40% TP (Standard Efficiency) 4 days - 85% TSS &0% TP (TSS- Only Efficiency) NCDENR: 2 - 5 days - 85%TSS &40% TP Watershed: Mountain and Piedmont(85% TSS) Efficiency: NCDENR Wet Pond Design (NCDENR - 2007) Project Name: Preserve at Forest Creek - Phase 2 (BMP-7) Job Number: 1021143 Step 1: Compute the water quality volume (WQV). WQv (Ft3) = (3630)x(RD)x(Rv)x (AD) Where: WQV =Water Quality Volume (Ft) AD = Drainage Area to Wet Pond (acres). Rv= Volumetric Runoff Coefficient= 0.05 + 0.9 (% Impervious) RD = Design Storm Rainfall Depth (in). Typically 1.0". Percent Impervious = 71% AD = 14.23 acres RD = 1.0 in Rv = 0.69 WQv = 35,481 Ft' Step 2: Determine Surface Area Requirements. Average Permanent Pool Depth = 3.42 Feet Percent Impervious = 71% SA/ DA Ratio = 2.88 Required Surface Area = 17,852 Ft2 Step 3: Preliminary Temporary Water Quality Drawdown Calculations Pond Height above Orifice = 646.30 feet Orifice Invert Elevation = 644.00 feet Pond Surface Area at Height Above Orifice = 29,378 square feet Pond Surface Area at Orifice Invert Elevation = 24,471 square feet Orifice Diameter(D) = 3.00 inches = 0.25 feet Orifice Area (a) = 0.0491 square feet Average Surface Area (A) = 26,925 square feet Gravitational Constatnt (g) = 32.2 ft/sec2 Head (H) = 2.17 feet Discharge Coefficient (C) = 0.6 Time (t) = 336,009 seconds = 3.89 days Note: The above calculation is based on the Bernoulli Equation where: -2 x A :xax (2g) Step 4: Compute Site Hydraulic Input Parameters. Condition Area (Ac) CN Tc (hours) Pre-developed 14.23 49 0.298 Post-developed 14.23 87 0.0833 Results Condition Q1-year Q10-year Q25-year Q50-year Pre-developed N/A 9.48 17.46 24.99 Post-developed N/A 8.32 16.00 33.69 Graph - 1 35,000.000 ----J 30,000.000 25,000.000 M 20,000.000 C) C 0 15,000.000 10,000.000 5,000.000 0.000 0.000 20.000 40.000 60.000 80.000 100.000 120.00, Time (hours) BMP-7 - Union County - Synthetic Curve, 1 yrs - Volume I Table of Contents Master Network Summary 1 Union County yrs) Time-Depth Curve, 1 years(Union County-Synthetic Curve, 1 2 POST-AREA-7 Time of Concentration Calculations, 1 years(Union County- 4 Synthetic Curve, 1 yrs) POST-AREA-7 Runoff CN-Area, 1 years(Union County-Synthetic Curve, 1 6 yrs) Elevation-Area Volume Curve, 1 years(Union County- BMP 7 Synthetic Curve, 1 yrs) 7 Riser-7 Outlet Input Data, 1 years(Union County-Synthetic Curve, 1 8 yrs) Subsection: Master Network Summary Catchments Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Event Volume (hours) (ft3/s) (years) (ft3) POST-AREA-7 Union County- 1 40,854.000 11.920 16.82 Synthetic Curve, 1 yrs Node Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Event Volume (hours) (ft3/s) (years) (ft3) OUTFALL Union County- 1 40,112.000 18.340 0.24 Synthetic Curve, 1 yrs Pond Summary Label Scenario Return Hydrograph Time to Peak Peak Flow Maximum Maximum Event Volume (hours) (ft3/s) Water Pond Storage (years) (ft3) Surface (ft3) Elevation (ft) BMP-7(IN) Union County- 1 40,854.000 11.920 16.82 (N/A) (N/A) Synthetic Curve, 1 yrs BMP-7 Union County- 1 40,112.000 18.340 0.24 645.17 31,130.000 (OUT) Synthetic Curve, 1 yrs Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition BMP-7 WQ.ppc Center [10.02.00.01] 10/10/2023 27 Siemon Company Drive Suite 200 W Page 1 of 12 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Time-Depth Curve Return Event: 1 years Label: Union County Storm Event: TypeII 24hr (1.0 in) Scenario: Union County- Synthetic Curve, 1 yrs Time-Depth Curve: TypeII 24hr(1.0 in) Label TypeII 24hr(1.0 in) Start Time 0.000 hours Increment 0.100 hours End Time 24.000 hours Return Event 1 years CUMULATIVE RAINFALL (in) Output Time Increment = 0.100 hours Time on left represents time for first value in each row. Time Depth Depth Depth Depth Depth (hours) (in) (in) (in) (in) (in) 0.000 0.0 0.0 0.0 0.0 0.0 0.500 0.0 0.0 0.0 0.0 0.0 1.000 0.0 0.0 0.0 0.0 0.0 1.500 0.0 0.0 0.0 0.0 0.0 2.000 0.0 0.0 0.0 0.0 0.0 2.500 0.0 0.0 0.0 0.0 0.0 3.000 0.0 0.0 0.0 0.0 0.0 3.500 0.0 0.0 0.0 0.0 0.0 4.000 0.0 0.0 0.1 0.1 0.1 4.500 0.1 0.1 0.1 0.1 0.1 5.000 0.1 0.1 0.1 0.1 0.1 5.500 0.1 0.1 0.1 0.1 0.1 6.000 0.1 0.1 0.1 0.1 0.1 6.500 0.1 0.1 0.1 0.1 0.1 7.000 0.1 0.1 0.1 0.1 0.1 7.500 0.1 0.1 0.1 0.1 0.1 8.000 0.1 0.1 0.1 0.1 0.1 8.500 0.1 0.1 0.1 0.1 0.1 9.000 0.1 0.2 0.2 0.2 0.2 9.500 0.2 0.2 0.2 0.2 0.2 10.000 0.2 0.2 0.2 0.2 0.2 10.500 0.2 0.2 0.2 0.2 0.2 11.000 0.2 0.2 0.3 0.3 0.3 11.500 0.3 0.3 0.4 0.4 0.6 12.000 0.7 0.7 0.7 0.7 0.7 12.500 0.7 0.7 0.8 0.8 0.8 13.000 0.8 0.8 0.8 0.8 0.8 13.500 0.8 0.8 0.8 0.8 0.8 14.000 0.8 0.8 0.8 0.8 0.8 14.500 0.8 0.8 0.8 0.8 0.9 15.000 0.9 0.9 0.9 0.9 0.9 15.500 0.9 0.9 0.9 0.9 0.9 16.000 0.9 0.9 0.9 0.9 0.9 16.500 0.9 0.9 0.9 0.9 0.9 Bentley Systems,Inc. Haestad Methods Solution Pond Pack CONNECT Edition BMP-7 WQ.ppc Center [10.02.00.01] 10/10/2023 27 Siemon Company Drive Suite 200 W Page 2 of 12 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Time-Depth Curve Return Event: 1 years Label: Union County Storm Event: TypeII 24hr (1.0 in) Scenario: Union County- Synthetic Curve, 1 yrs CUMULATIVE RAINFALL (in) Output Time Increment = 0.100 hours Time on left represents time for first value in each row. Time Depth Depth Depth Depth Depth (hours) (in) (in) (in) (in) (in) 17.000 0.9 0.9 0.9 0.9 0.9 17.500 0.9 0.9 0.9 0.9 0.9 18.000 0.9 0.9 0.9 0.9 0.9 18.500 0.9 0.9 0.9 0.9 0.9 19.000 0.9 0.9 0.9 0.9 0.9 19.500 0.9 0.9 0.9 0.9 1.0 20.000 1.0 1.0 1.0 1.0 1.0 20.500 1.0 1.0 1.0 1.0 1.0 21.000 1.0 1.0 1.0 1.0 1.0 21.500 1.0 1.0 1.0 1.0 1.0 22.000 1.0 1.0 1.0 1.0 1.0 22.500 1.0 1.0 1.0 1.0 1.0 23.000 1.0 1.0 1.0 1.0 1.0 23.500 1.0 1.0 1.0 1.0 1.0 24.000 1 1.0 (N/A) I (N/A) I (N/A) I (N/A) Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition BMP-7 WQ.ppc Center [10.02.00.01] 10/10/2023 27 Siemon Company Drive Suite 200 W Page 3 of 12 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Time of Concentration Calculations Return Event: 1 years Label: POST-AREA-7 Storm Event: TypeII 24hr (1.0 in) Scenario: Union County- Synthetic Curve, 1 yrs Time of Concentration Results Segment#1: User Defined Tc Time of Concentration 0.083 hours Time of Concentration(Composite) Time of Concentration 0.083 hours (Composite) Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition BMP-7 WQ.ppc Center [10.02.00.01] 10/10/2023 27 Siemon Company Drive Suite 200 W Page 4 of 12 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Time of Concentration Calculations Return Event: 1 years Label: POST-AREA-7 Storm Event: TypeII 24hr (1.0 in) Scenario: Union County- Synthetic Curve, 1 yrs ==== User Defined Tc = Value entered by user Where: Tc=Time of concentration, hours Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition BMP-7 WQ.ppc Center [10.02.00.01] 10/10/2023 27 Siemon Company Drive Suite 200 W Page 5 of 12 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Runoff CN-Area Return Event: 1 years Label: POST-AREA-7 Storm Event: TypeII 24hr (1.0 in) Scenario: Union County- Synthetic Curve, 1 yrs Runoff Curve Number Data Soil/Surface Description CN Area C UC Adjusted CN (acres) (%) (%) Impervious Areas- Paved parking lots, 98.000 14.230 0.0 0.0 98.000 roofs,driveways, Streets and roads COMPOSITE AREA&WEIGHTED CN---> (N/A) 14.230 (N/A) (N/A) 98.000 Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition BMP-7 WQ.ppc Center [10.02.00.01] 10/10/2023 27 Siemon Company Drive Suite 200 W Page 6 of 12 Watertown,CT 06795 USA +1-203-755-1666 Subsection: Elevation-Area Volume Curve Return Event: 1 years Label: BMP-7 Storm Event: TypeII 24hr (1.0 in) Scenario: Union County- Synthetic Curve, 1 yrs Elevation Planimeter Area Al+A2+sqr Volume Volume(Total) (ft) (ftz) (acres) (A1*A2) (ft3) (ft3) (acres) 644.00 0.0 0.572 0.000 0.000 0.000 644.50 0.0 0.610 1.773 12,870.000 12,870.000 645.00 0.0 0.630 1.860 13,503.000 26,373.000 646.00 0.0 0.666 1.944 28,223.000 54,596.000 647.00 0.0 0.695 2.041 29,640.000 84,236.000 648.00 0.0 0.725 2.130 30,925.000 115,162.000 649.00 0.0 0.756 2.221 32,254.000 147,415.000 650.00 1 0.0 1 0.787 1 2.314 1 33,604.000 1 181,020.000 Bentley Systems,Inc. Haestad Methods Solution PondPack CONNECT Edition BMP-7 WQ.ppc Center [10.02.00.01] 10/10/2023 27 Siemon Company Drive Suite 200 W Page 7 of 12 Watertown,CT 06795 USA +1-203-755-1666