Loading...
HomeMy WebLinkAboutNCG550679_WW System Inspecition Report and Lab Data_20240228 McFarland Septic LLC 6801 Mt. Herman Church Road Durham, NC 27705 (919) 383-1015 (919) 732-5007 ® Pre-Inspection Contract,signed by Client is attached to Inspection. Date:12/1/2021 System Address:100 Briar Patch Lane System Zip Code:27516 Inspection Requested By:Shelby Bishop-Buyer's Agent System Owner:Marit Nelson and Amanda Mixon ® Inspection shall include any part of the system located more than 5 feet from the primary structure that is part of the operations permit. Type of System:Sand Filter Type of water supply:Public Water Number of Bedrooms as advertised in MLS or as stated in attached sworn statement by owner or owner's representative:Three Gallons per day for designed system size or number of bedrooms as stated in local health department information.360 Is the property occupied at the time of inspection?Yes❑No® * • If home is unoccupied the septic inspection may be less accurate. Yes No N/A Does System require a Subsurface Operator? ® ❑ ❑ Copy of latest report attached? ® ❑ ❑ Operator Name: Randle Jarrell Operator Phone:919-210-2500 Conditions at time of inspection:Dry TANKAGE: Location of septic tank: 2 ft.from house or structure. n/a ft.from well if applicable. unk ft.from water line if applicable. unk ft.from property line if property lines are marked or known. Yes No N/A Riser's accessible,surface water diverted? ® ❑ ❑ Risers structurally sound,and watertight? ® ❑ ❑ Number of access risers?1 Approximate distance to top of Tank from surface. 12" Tank lids intact? ❑ Tank accessible(Not under driveway/building) ® ❑ Any evidence of Tank leakage? ❑ Describe:none Any evidence of surface water infiltration into tank? ❑ Tank has baffle wall? Condition of baffle wall.n/a ❑ Effluent Filter present? Filter Type?n/a ❑ ❑ Effluent Filter cleaned at inspection? ❑ ❑ Water level in tank is relative to tank outlet? ® ❑ Outlet T is present?Condition of Outlet T?Fair ® ❑ Roots present in Tank? ❑ Describe extent of roots.none Sludge 5"Scum 6" Total Solids 11"<1/3 of tank volume of 50 Inches. ® ❑ Percentage of solids in the tank:22% Yes No N/A Is the Septic Tank due for pumping? ❑ Date when Tank was last pumped:unk Unknown Was Tank pumped during inspection? ® ❑ Evidence of non-permitted connections? ❑ Connection present from house to tank? ® ❑ Connection from tank to next component? ® ❑ 1 McFarland Septic LLC 6801 Mt. Herman Church Road Durham, NC 27705 (919) 383-1015 (919) 732-5007 Drainage into Tank sufficient? Unknown® ❑ ❑ EFFLUENT DOSING SYSTEM: Location of pump tank: n/a ft.from house or structure. n/a ft.from well if applicable. n/a ft.from water line if applicable. n/a ft.from property line if property lines are marked or known. Yes No N/A Riser's accessible,surface water diverted? ❑ ❑ Risers structurally sound,and watertight? ❑ ❑ Solids depth<4 inches? ❑ ❑ Required pumps present,operating,and cycling properly? ❑ ❑ High-Water Alarm present and operating properly? ❑ ❑ Vents/Floats/Pipe/Disconnects in good working condition? ❑ ❑ Control Panel/Electrical Components in good condition? ❑ ❑ Power Indicator Lamps working? ❑ ❑ DELIVERY RATE/PRESSURE HEAD Design Rate Measured Rate Pump Tank Size-n/a gpm @ ft. V min. x gpi = gpm @ ft.head Percent Efficiency of Delivery=[Measured Rate/Design Rate]X 100= %Alarm Count: Elapsed Time Meter: Events Meter: Timer left at: minutes"on"& hours"off" GROUND ABSORPTION FIELDS: Yes No N/A Evidence of effluent surfacing/reaching surface waters? ❑ ® ❑ Line cover/vegetation adequate/maintained as needed? ® ❑ ❑ Evidence of traffic over Drainfield? ❑ ® ❑ Depressions on Drainfield? ❑ ® ❑ Distribution Devices accessible? ❑ ❑ Distribution Devices in good working condition/working properly? ❑ ❑ Turn-ups/Cleanouts/VaIves intact and accessible? ❑ ❑ Effluent standing in Laterals?(for LPP only) ❑ ❑ Functional system drainage? ® ❑ ❑ Feet from property lines. If known or marked.unk Feet from Septic/Pump tank?6' Number of lines?0 Length of lines?6'x60' Yes No Effluent is reaching the dispersal field? ® ❑ Conditions were present that hindered or prevented the inspection. ❑ Adverse conditions were present that require repair or subsequent ❑ observation or warrants further evaluation by the local health department.(description noted below in comment section) Client should contact the Chatham County Health Department and ❑ or a Certified On-site Wastewater Contractor. Are there underground utilities? ® ❑ Are there underground Gas lines? ❑ ®Copy of Operations permit attached. ❑Operations Permit is unavailable. 2 McFarland Septic LLC 6801 Mt. Herman Church Road Durham, NC 27705 (919) 383-1015 (919) 732-5007 The followin ictures were taken durin the inspection. Description:Location of Tank Description:Broken Handle on Outlet lid a. Description:Chlorinator Caps Broken Description:Inside of Tank Conclusions: 1.House was Vacant at time of Inspection.2.Handle on the Outlet Lid of Septic Tank was broken.3.No Inner Lid inside Inlet Riser.4.The Inlet Riser was at grade which could allow for Ground water to enter the septic system.5.There were Chlorine and Dechlorine Tablets in the Chlorinator and Dechlorinator.6.I performed a 20-minute water test of the drainfield/sandfilter and found that it was absorbing water properly at time of Inspection.7.I was unable to get the sandfilter to discharge during the water test,which may be due to the house being vacant and system not being regularly used.8.There are Annual Waste Water Samples that are required per state guidelines.I will attached the latest results from the testing in October. Certified Inspector Inspector's Signature Certification#2742I Adam Moneypenny **Note—No representation,warranties or opinions are hereby given,written or expressed otherwise,as to the future performance of the onsite wastewater system described herein. This onsite wastewater system inspection is a presentation of system facts in place on the date of the inspection. ***Note-If a Water Softener/Treatment system is being used,be sure the backwash is not plumbed into the septic tank. 3 ENVIRONMENTAL - WATER SUPPLY - WASTEWATER CONNER CONSULTING, LLC 1 284 WINDY RIDGE ROAD, CHAPEL HILL, NORTH CAROLINA 27517 PHONE: (919) 260.7301 ........................................................................... November 23, 2022 Mr. Steven Horton 100 Briar Patch Lane Chapel Hill,North Carolina 27516 Re: Effluent Sampling 100 Briar Patch Lane Chatham County,North Carolina Dear Mr. Horton: On November 7, 2022, Conner Consulting collected effluent samples as required on your DWQ permit, at 100 Briar Patch Lane, Chatham County. The results are as follows: Flow: < 300 gpd(estimated) Total Residual Chlorine: 0.07 parts per million @ 08:55 Biochemical Oxygen Demand: 59 mg/1 Total Suspended Solids: 72 mg/1 Fecal Coliform: 67 CFU/100 ml The system appeared to be working well. Please remember to add at least 1 chlorine tablet to your chlorinator each week and 1 dechlor tablet. My field laboratory certification is#5149. Please call with questions and comments. Sincerely yours, Chad Leinbach Conner Consulting, LLC Field Laboratory Certification#5149 CC: Mitch Hayes, Surface Water Protection,NCDEQ =Qp ENCO L a bona tofies lgepR��(+ Accurate. Timely. Respousive. Iuuovative. 102-A Woodwinds Industrial Court Cary NC,27511 Phone: 919.467.3090 FAX: 919.467.3515 Friday, November 18, 2022 CONNER CONSULTING (CO036) Attn: Chad Leinbach 1284 WINDY RIDGE RD CHAPEL HILL, NC 27517 RE: Laboratory Results for Project Number: 100 BRIAR PATCH, Project Name/Desc: Wastewater-Misc. ENCO Workorder(s): CF16702 Dear Chad Leinbach, Enclosed is a copy of your laboratory report for test samples received by our laboratory on Wednesday, November 9, 2022. Unless otherwise noted in an attached project narrative, all samples were received in acceptable condition and processed in accordance with the referenced methods/procedures. Results for these procedures apply only to the samples as submitted. The analytical results contained in this report are in compliance with NELAC standards, except as noted in the project narrative if applicable. This report shall not be reproduced except in full, without the written approval of the Laboratory. This report contains only those analyses performed by Environmental Conservation Laboratories. Unless otherwise noted, all analyses were performed at ENCO Cary. Data from outside organizations will be reported under separate cover. If you have any questions or require further information, please do not hesitate to contact me. Sincerely, ,(jylvld�` Daniel G. Harmon Project Manager Enclosure(s) FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 1 of 7 CIE.NCO www.encolabs.com SAMPLE SUMMARY/LABORATORY CHRONICLE Client ID: EFF-100 BRIAR PATCH Lab ID: CF16702-01 Sampled: 11/09/22 09:00 Received: 11/09/22 10:11 Parameter Preparation Hold Date/Time(s) Prep Date/Time(s) Analysis Date/Time(s) Colilert 18 NO PREP 11/09/22 16:55 11/10/22 11:47 11/09/22 13:43 11/10/22 10:43 SM 254OD-2015 NO PREP 11/16/22 11/11/22 10:21 11/11/22 10:21 SM 5210 B-2011 NO PREP 11/11/22 09:00 11/10/22 10:36 11/10/22 10:36 FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. I Page 2 Of 7 CIE.NCO www.encolabs.com SAMPLE DETECTION SUMMARY Client ID: EFF-100 BRIAR PATCH Lab ID: CF16702-01 Analvte Results Flag MDL 4 Units Method Notes Biochemical Oxygen Demand 59 2.0 2.0 mg/L SM 5210 B-2011 Coliform,Fecal 67 1.0 1.0 MPN/100 mL Colilert 18 Total Suspended Solids 72 12 12 mg/L SM 2540D-2015 FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. I Page 3 Of 7 CIE.NCO www.encolabs.com ANALYTICAL RESULTS Description: EFF- 100 BRIAR PATCH Lab Sample ID:CF16702-01 Received: 11/09/22 10:11 Matrix: Waste Water Sampled:11/09/22 09:00 Work Order: CF16702 Project: Wastewater-Misc. Sampled By:Chad Leibach Classical Chemistry Parameters Analyte rCAS Numberl Results Flao Units DF MDL P L Batch Method Analyzed —By Notes Biochemical Oxygen Demand 59 mg/L 1 2.0 2.0 2K10009 SM 5210 B-2011 11/10/22 10:36 JOC Total Suspended Solids 72 mg/L 5 12 12 2KII003 SM 254OD-2015 11/11/22 10:21 JOC Microbiological Parameters Analyte rCAS Numberl Results Flao Units DF MDL P L Batch Method Analyzed By Notes Coliform,Fecal 67 MPN/100 1 1.0 21<11009 Colilert 18 11/10/22 10:43 CB mL FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 4 Of 7 CIE.NCO www.encolabs.com QUALITY CONTROL DATA Classical Chemistry Parameters-Quality Control Batch 2K10009-NO PREP Blank(2K10009-BLK1) Prepared&Analyzed: 11/10/2022 10:36 Spike Source %REC RPD Analvte Result Flaq Q Units Level Result %REC Limits RPD Limit Notes Biochemical Oxygen Demand 2.0 u 2.0 mg/L LCS(2K30009-BS3) Prepared&Analyzed: 11/10/2022 10:36 Spike Source %REC RPD Analvte Result Flaq POL Units Level Result %REC Limits RPD Limit Notes Biochemical Oxygen Demand 200 2.0 mg/L 198 101 85-115 Duplicate(2K10009-DUPI) Prepared&Analyzed: 11/10/2022 10:36 Source:CF13572-01 Spike Source %REC RPD Analvte Result Flaq POL Units Level Result %REC Limits RPD Limit Notes Biochemical Oxygen Demand 4800 2.0 mg/L 4800 0.2 30 Batch 2KI1003-NO PREP Blank(2K13003-BLK1) Prepared&Analyzed: 11/11/2022 10:21 Spike Source %REC RPD Analvte Result Flaq Q Units Level Result %REC Limits RPD Limit Notes Total Suspended Solids 2.5 u 2.5 mg/L LCS(2K31003-BS3) Prepared&Analyzed: 11/11/2022 10:21 Spike Source %REC RPD Analvte Result Flaq POL Units Level Result %REC Limits RPD Limit Notes Total Suspended Solids 110 2.5 mg/L 100 110 80-120 Duplicate(2K11003-DUPI) Prepared&Analyzed: 11/11/2022 10:21 Source:CF15391-01 Spike Source %REC RPD Analvte Result Flaq POL Units Level Result %REC Limits RPD Limit Notes Total Suspended Solids 11 10 mg/L 10 4 20 Duplicate(21(11003-DUP2) Prepared&Analyzed: 11/11/2022 10:21 Source:CF16702-01 Spike Source %REC RPD Analvte Result Flaq POL Units Level Result %REC Limits RPD Limit Notes Total Suspended Solids 75 12 mg/L 72 3 20 Microbiological Parameters-Quality Control Batch 2KII009-NO PREP Duplicate(2K11009-DUP3) Prepared: 11/09/2022 14:08 Analyzed:11/10/2022 10:43 Source:CF16168-02 Spike Source %REC RPD Analvte Result Flaq POL Units Level Result %REC Limits RPD Limit Notes Coliform,Fecal 1.0 u 1.0 MPN/100 mL 1.0 u 25 Duplicate(2K33009-DUP2) Prepared: 11/09/2022 14:08 Analyzed:11/10/2022 10:43 Source:CF16321-01 Spike Source %REC RPD Analvte Result Flaq POL Units Level Result %REC Limits RPD Limit Notes Coliform,Fecal 1.0 u 1.0 MPN/100 mL 1.0 u 25 FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Pager) Of 7 CIE.NCO www.encolabs.com FLAGS/NOTES AND DEFINITIONS B The analyte was detected in the associated method blank. D The sample was analyzed at dilution. J The reported value is between the laboratory method detection limit(MDL)and the laboratory method reporting limit(MRL), adjusted for actual sample preparation data and moisture content,where applicable. U The analyte was analyzed for but not detected to the level shown,adjusted for actual sample preparation data and moisture content,where applicable. E The concentration indicated for this analyte is an estimated value above the calibration range of the instrument.This value is considered an estimate. MRL Method Reporting Limit.The MRL is roughly equivalent to the practical quantitation limit(PQL)and is based on the low point of the calibration curve,when applicable,sample preparation factor,dilution factor, and, in the case of soil samples, moisture content. PQL PQL: Practical Quantitation Limit. The PQL presented is the laboratory MRL. N The analysis indicates the presence of an analyte for which there is presumptive evidence(85%or greater confidence)to make a"tentative identification". P Greater than 25%concentration difference was observed between the primary and secondary GC column. The lower concentration is reported. [CALC] Calculated analyte- MDL/MRL reported to the highest reporting limit of the component analyses. FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 6 of 7 l� IA cU c O F y a Q^ O V a E d m X `) U (n W a N E E E a, N N m a h. - Y e d 3 co � a� �, 3 QN ¢ � C = m cvj E � Q O U C O � U 9 m h Z m m O Q o ^^ = m O m `l N m LLj 2 � H = Z m m y m m ? E N W yyy 'ov N n z z 10 U � _ o m o = N LL N o 0 m `o c c m = U E E E 0 r V 0 � o m E E o 0 0 0 r � o Or V cc��yy Z LL $ //�/ N O cc V \ C Q @ W d c Cl) N y ¢ iD Z m m L J o ` 8 E C) qkm m F U o m g qF �v of 3w z a = m = o m c c Z a m 2 o m = U c N O m 7 a a a ¢ m (n o cr y LL Z r:, g = E W c? y o N 2 m m / C r r _ N C u O m � � g o \ d g Q W V m d ' 9 Q D m n ¢ Z m o m a m O v z E E E E j Page 7 of 7 U 4 U F� in cn m vj C