HomeMy WebLinkAboutSW6230705_Design Calculations_20240304 (26) SERENTIY SCM#14 Drainage Area: 658,114 sf 15.11 ac Impervious Area: 317,703 sf 7.29 ac %Impervious: 48.3% 1 inch Storm Event: Rv=0.05+0.009 I Rv=runoff coefficient I=percent impervious Rv= 0.4845 For volume that must be controlled: Volume=3,630*Rd*Rv*A Volume required: 26,570 cf Volume provided: 28499 cf Average depth: 3.9 ft SA/DA ratio 1.5 Required surface area: 9872 sf Surface area provided: 10658 sf