HomeMy WebLinkAboutSW6230705_Design Calculations_20240304 (14) SERENTIY 3,4&5 SCM 13 Antiflotation Calculation Input Data Safety Factor: 1.5 Top Width of Riser(ft) 5 Top Length of Riser(ft) 4 Thickness of Riser(ft) 0.5 Thickness of Bottom of Riser(ft) 0.5 Top of Riser(ft) 312.5 Invert of Riser(ft) 307.5 Volume of Riser(cf) 50 Unit Weight Of Concrete(lb/cf) 150 Unit Weight of Water(lb/cf) 62.4 Block Height(ft) 1 Block Width(ft) 5 Block Length(ft) 4 Output Fw(Uplift Force,lb) 6240 Fc(Weight of Concrete,lb) 10500 Design Volume(cf) 70 Design Safety Factor 1.68 Volume OK