HomeMy WebLinkAboutSW5240101_Supplement-EZ Form_20240301 SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION i 1 Project Name Siler City WWTP Expansion 2 Project Area(ac) 55.26 3 Coastal Wetland Area(ac) 0 4 Surface Water Area(ac) 0.69 • 5 Is this project High or Low Density? Low 6 •Does this project use an off-site SCM? No • COMPLIANCE WITH 02H.1003(4) 7 'Width of vegetated setbacks provided(feet) 30 8 Will the vegetated setback remain vegetated? Yes 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c d)? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System _ 0 12 Bioretention Cell 0 13 Wet Pond 0 14 Stormwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 0 17 Rainwater Harvesting(RWH) _ 0 18 Green Roof 0 19 Level Spreader-Filter Strip(LS-FS) 0 20 Disconnected Impervious Surface(DIS) _ 0 21 Treatment Swale 0 22 'Dry Pond 0 23 StormFilter 0 24 'Silva Cell 0 25 -Bayfilter 0 26 •Filterra 0 FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: David Honeycutt.PE 28 Or.anization: McGill Associates 29 Street address: _ 5 Regional Circle,Suite A 30 Ci ,State,Zi.: Pinehurst,NC 28374 ®Phone number(s: 910-295-3159;910-690-2583(cell) 32 ;Email: j david.honeycuttimcgillassociates.com Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer „ FESs/p• SEAL • Signature of Designer -QE 03499g =� �p 0irvE y, (720z NIIIIyI/I�NyIAN.,•lr ` / '''Is •'"Iv'wo Date DRAINAGE AREAS 1 Is this a high density project? No 2 If so,number of drainage areas/SCMs 0 3 Does this project have low density areas? Yes 4 If so,number of low density drainage areas 1 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site LD 1 4 Type of SCM N/A N/A 5 Total drainage area(sq ft) 2,407,126 2407126 6 Onsite drainage area(sq ft) 2,407,126 2407126 7 Offsite drainage area(sq ft) 0 0 8 Total BUA in project(sq ft) 174517 sf 174517 sf New BUA on subdivided lots(subject to permitting) 9 l(sq ft) NA N/A New BUA not on subdivided lots(subject to 10 permitting)(sf) 58475 sf 58475 sf 11 Offsite BUA(sq ft) sf sf 12 Breakdown of new BUA not on subdivided lots: -Parking(sq ft) sf sf -Sidewalk(sq ft) 2587 sf 2587 sf -Roof(sq ft) 10682 sf 10682 sf -Roadway(sq ft) 36081 sf 36081 sf -Future(sq ft) sf sf -Other,please specify in the comment box below(sq ft) 9125 sf 9125 sf New infiltrating permeable pavement on 13 subdivided lots(sq ft) NA N/A New infiltrating permeable pavement not on 14 subdivided lots(sq ft) NA N/A Existing BUA that will remain(not subject to 15 permitting)(sq ft) 116042 sf 116042 sf 16 Existing BUA that is already permitted(sq ft) N/A N/A 17 Existing BUA that will be removed(sq ft) N/A N/A 18 Percent BUA 7% 7% 19 Design storm(inches) N/A N/A 20 Design volume of SCM(cu ft) N/A _ N/A 21 Calculation method for design volume N/A N/A ,ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): The other impervious includes various features of the WWTP such as headworks,clarifier,anaerobic basin,valve vaults,etc. LOW DENSITY (DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H.1003 W 1 its project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per.1003(2)(c)? I Yes 4 Side slopes of the vegetated conveyances(H:V) (3:1) 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 4.16 6 ;Are curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s)(%) N/A - 8 Bottom width of curb outlet swale(s)(feet) i N/A 9 Maximum side slope of curb outlet swale(s)(H:V) N/A 10 Minimum length of curb outlet swale(s)(feet) N/A 11 Are treatment swales used instead of curb outlet swales? N/A 12 Is stormwater released at the edge of the setback as dispersed flow? Yes 13 Have stormwater outlets been designed to prevent downslope erosion? I Yes • 14 Are variations to rule.1003 proposed? No ;ADDITIONAL INFORMATION s I15 Please use this space to provide any additional information about this low density project: I ji 1 1 I I _y II Swale Drainage BUA Pervious I O I Slope V,Ro„ V.,„,„, 1 Flow depth , Area# (ac) (ac) (a�1 C (cfs) (%) (fps) (fps) (ft) 1 0.67 0.06 0.61 0.44 i 1.74 3.40 - 5.50 2.86 0.45 2 1.39 0.24 1.15 0.35 2.86 i 7.77 5.00 4.16 0.34 3 0.14 0.00 0.14 0.16 0.13 I- 5.83 5.00 1.00 0.10 4 5 6 I it 2 1