Loading...
HomeMy WebLinkAboutNC0064734_Compliance Report_20240304K & W Laboratories 1121 Hwy 24/27 W Midland, North Carolina 28107 Tel (704) 888-1211 Fax (704) 888-1511 Client: Carolina Water Service, Inc. PO Box 240908 Charlotte, NC 28224-0908 Project: Bradfield Farms Location: Effluent SAMPLE# PARAMETER RESULT UNITS 23101214-01 Ammonia Nitrogen <0.1 mg/L 23101214-01 BOD <2 mg/L 23101214-01 Fecal Coliform <7 colony/100ml 23101214-01 NO2+NO3 Nitrogen 0.45 mglL 23101214-01 TKN <1 mg/L 23101214.01 Total Nitrogen 0.45 mg/L 23101214-01 Total Phosphorus <0.05 mg/L 23101214-01 TSS <2.8 mg/L Results Report Date: 08-Nov-23 Order ID: 23101214 Collect Date: 10/12/2023 Collect Time: 1:30:00 PM S9-� 4 REPORTING ANALYSIS METHOD LIMIT DATE SM4500NH3D 0.1 10/13/2023 SM5210B 2 10/13/2023 SM9222D(MF) 1 10/12/2023 SM450ONO3F 0.05 10/30/2023 SM4500NH3D 1 10/13/2023 Calculation 0.05 10/30/2023 SM450OP-F 0.05 10/20/2023 SM2540D 2.8 10/13/2023 INC Certification: 559 SC Certification: 99051 Certified By 6-kso,ka G. Kraska / Lab Director K & W Laboratories 1121 Hwy 24/27 W Midland, North Carolina 28107 Tel(704) 888-1211 Fax (704)888-1511 Client: Carolina Water Service, Inc. PO Box 240908 Charlotte, NC 28224-0908 Project: Bradfield Farms - Up Location: Upstream SAMPLE# PARAMETER 2310121501 Fecal Coliforrn RESULT 445 Results Re„ A Date: 08-Nov-23 OrderlD: 23101215 Collect Date: Collect Time: UNITS METHOD colony/100m1 SM9222D (MF) 10/12/2023 pol , 1:40:00 PM REPORTING ANALYSIS LIMIT DATE 1 10/12/2023 PCI . NC Certification: 559 SC Certification: j305'1 Certified By _4�-Kraosa.9- G. Kraska / Lab Director K& W Laboratories Results Report 1121 Hwy 24/27 W Midland, North Carolina 28107 Tel (704) 888-1211 Fax (704) 888-1511 Client: Carolina Water Service, Inc. Date: 08-Nov-23 PO Box 240908 Order ID: 23101216 Charlotte, NC 28224-0908 Project: Bradfield Farms - Dn Collect Date: 10/12/2023 Location: Downstream Collect Time: 1:50:00 PM REPORTING ANALYSIS SAMPLE# PARAMETER RESULT UNITS METHOD LIMIT DATE 23101216.01 Feral Coliforrn 630 colony/100mi SM9222D (MF) 1 10/12/2023 NC Certification: 559 SC Certification: 99051 Certified By 6 k o,&, G. Kraska / Lab Director NUMBER of Sample Bottles Lab to be used CAROLINA WATER SERVICE, INC. of NORTH CAROLINA WASTEWATER CHAIN OF CUSTODY NPDES NUMBER IN G t- ' 1 FACILITY NAME & SUBDIVISION NUMBER birfo CA wrn DATE COLLECTOR � k C a u� TIME COLLECTED EFF 1530 UP S40 DN 1 COMP. SAMPLER COLLECTION SAMPLER TYPE WEATHER 1 I t FIELD PH FIELD D.O. m /I EFF ?. 70 UP %-ZL DN I %-9 SAMPLE TEMP °C EFF Zq-4 UP 3 DN CHLORINE RESIDUAL m /l - u I OPERATOR RELINQUISHED BY INITIALS/DATE/TIME i IC'. LAB DELIVERED TO I C' n 3 , a jof I>h ( r DATE / TIME RECEIVED BY LAB / TEMP li. " �-D RECEIVED BY PARAMETERS REQUIRING ANALYSIS INF EFF UP DN PRESERVA IVES H m K r ° COMMENTS 73101 N z s z i �6� s h S.U. Z510174 S CONDUCTIVITY o 1 1 la BOD (mg/1) / I/ T.S.S. m /I E. COLI m n /100ml _ D.O. m /I NH3-N m /I )412 dN D T-PO, m /1 T-NITROGEN m /I OTHER MIXED LIQUOR SUSPENDED SOLIDS MIXED LIQUOR VOLITILE SUSPENDED SOLIDS Composite Sam Ier Information Ice Temperature Start Date/Time - 11. 23 3 b 4T Stop Date/Time 10 -it -Z q` R. VlR