Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0022241_Modification Application (FTSE)_20240209
NC Dept. of Environmental Quality State of North Carolina Oct 24 2023 Department of Environmental Quality DWR Raleigh Regional Office Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 06-21 &SUPPORTING DOCUMENTATION Application Number: Q002224 OD (to be completed by DwR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: City of Roxboro(company,municipality,HOA,utility,etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑Privately-Owned Public Utility ❑ Federal ❑ State/County ®Municipal ❑ Other 3. Signature authority's name: Brooks Lockhart per 15A NCAC 02T.0106(b) Title:Ci, Manager 4. Applicant's mailing address:PO Box 128 City: Roxboro State:NC Zip: 27573- 5. Applicant's contact information: Phone number: (336)322-6010 Email Address:blockhart(a),cityofroxboro.com II. PROJECT INFORMATION: 1. Project name:Western Sewer System—Gravity Sewer,Force Main and Southside Pump Station 2. Application/Project status: ❑Proposed(New Permit) ®Existing Permit/Project If a modification,provide the existing permit number:WQ0022241 and issued date: February 2003, For modifications,also attach a detailed narrative description as described in Item G of the checklist. If new construction,but part of a master plan,provide the existing permit number:WQ00 3. County where project is located:Person 4. Approximate Coordinates(Decimal Degrees):Latitude: 36.34923' Longitude: -78.99170' 5. Parcel ID(if applicable): Map,and List of Properties attached separately(or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Jeffrey Sweater License Number: 056476 Firm:LaBella Associates Mailing address:400 S.Tryon Street City: Charlotte State:NC Zip: 28285- Phone number: (941)374-3930 Email Address:jsweaterglabellapc.com IV. WASTEWATER TREATMENT FACILITY(WWTF)INFORMATION: 1. Facility Name:Roxboro WWTP Permit Number:NCO021024 Owner Name: City of Roxboro V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. Permit Number(s):NC 0021024(Connection to Existing WWTP) 2. Downstream(Receiving) Sewer Information: inch ❑ Gravity ❑ Force Main 3. System Wide Collection System Permit Number(s)(if applicable):WQCS00048 Owner Name(s): City of Roxboro FORM:FTA 06-21 Page 1 of 5 NC Dept. of Environmental Quality Feb 6 VI. GENERAL REQUIREMENTS Raleigh Regional Office 1. If the Applicant is a Privately-Owned Public Utility,has a Certificate of Public Convenience and Necessity been attached? [:]Yes [:]No ®N/A 2. If the Applicant is a Developer of lots to be sold,has a Developer's Operational Agreement(FORM:DEV)been attached? ❑Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners'Association,has an HOA/POA Operational Agreement(FORM: HOA)and supplementary documentation as required by 15A NCAC 02T.0115(c)been attached? ❑Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ❑Residential(Individually Owned) ❑Retail(stores,centers,malls) ❑ Car Wash ❑Residential(Leased) ❑Retail with food preparation/service ❑Hotel and/or Motels ❑ School/preschool/day care ❑ Medical/dental/veterinary facilities ❑ Swimming Pool/Clubhouse ❑Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑Businesses/offices/factories ❑Nursing Home ❑ Other(Explain in Attachment) 5. Nature of wastewater: N/A%Domestic N/A%Commercial N/A%Industrial(See 15A NCAC 02T .0103(20)) If Industrial,is there a Pretreatment Program in effect? ❑Yes❑No 6. Hasa flow reduction been approved under 15A NCAC 02T.0114(f)? ❑Yes ❑No ➢ If yes,provide a copy of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type(see 02T.0114(f)) Daily Design Flow a,b No.of Units Flow N/A(see Supplemental FTA Narrative) gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 0 GPD a See 15A NCAC 02T .0114(b)(d), (e (1) and(e)(2) for caveats to wastewater design flow rates (i.e. proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S.42A-4). b Per 15A NCAC 02T.0114(c),design flow rates for establishments not identified[in table 15A NCAC 02T.01141 shall be determined using available flow data,water using fixtures,occupancy or operation patterns,and other measured data. 8. Wastewater generated by project: 0 GPD(per 15A NCAC 02T.0114 and G.S. 143-215.1) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero,please indicate why: ®Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑Flow has already been allocated in Permit Number: Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other(Explain): FORM: FTA 10-23 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA(If Applicable)-02T.0305&MDC(Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size(inches) Length(feet) Material 24 2,868 PVC&DIP 18 17,375 PVC&DIP ➢ Section II&III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA(If Applicable)—02T.0305&MDC(Puma Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: Southside Pump Station 2. Approximate Coordinates(Decimal Degrees):Latitude: 36.34923' Longitude: -78.99170' 3. Total number of pumps at the pump station:2 3. Design flow of the pump station: 2.016 millions gallons per day(firm capacity) ➢ This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s)per pump(s): 1400 gallons per minute(GPM)at 218 feet total dynamic head(TDH) 5. Summarize the force main to be permitted(for this Pump Station): Size(inches) Length(feet) Material 16 23,118 PVC/DIP If any portion of the force main is less than 4-inches in diameter,please identify the method of solids reduction per MDCPSFM Section 2.01C.l.b. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other(please specify) 6. Power reliability in accordance with 15A NCAC 02T.0305(h)(1): ® Standby power source or ® Standby pump ➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B)_ ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation,quick-connection receptacle and telemetry- or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: ➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations,an evaluation of all the pump stations'storage capacities and the rotation schedule of the portable power source or pump,including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06-21 Page 3 of 5 IX. SETBACKS&SEPARATIONS—(02B.0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations/alternatives found in 15A NCAC 02T.0305(f)&(g)? ®Yes [-]No 15A NCAC 02T.0305 contains minimum separations that shall be provided for sewers stems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below(vertical) 18 inches zWater mains(vertical-water over sewer preferred,including in benched trenches) 18 inches zWater mains(horizontal) 10 feet Reclaimed water lines(vertical-reclaimed over sewer) 18 inches Reclaimed water lines(horizontal-reclaimed over sewer) 2 feet **Any private or public water supply source,including any wells,WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water,and associated wetlands. 100 feet **Waters classified WS (except WS-I or WS-V),B,SA,ORW,HQW,or SB from normal high water(or tide elevation)and wetlands associated with these waters(see item IX.2) 50 feet **Any other stream,lake,impoundment,or ground water lowering and surface drainage ditches,as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation(horizontal) 5 feet Any basement(horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade(vertical) 36 inches ➢ If noncompliance with 02T.0305(f)or(g), see Section X.1 of this application *I 5A NCAC 02T.0305(g)contains alternatives where separations in 02T.0305(f)cannot be achieved.Please check"yes" above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage 2. Does this project comply with the minimum separation requirements for water mains? ®Yes ❑No ❑N/A ➢ If no,please refer to 15A NCAC 18C.0906(f)for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE,verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ®Yes [—]No ❑N/A ➢ Please provide supplementary information identifying the areas of non-conformance. ➢ See the Division's draft separation requirements for situations where separation cannot be met. ➢ No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ®Yes Basin name:Neuse ❑No If yes,does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ®Yes ❑No ➢ This includes Trout Buffered Streams per 15A NCAC 213.0202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ®Yes ❑No or 401 Water Quality Certifications? ➢ Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15A NCAC 02T.0105(c)(6)(additional permits/certifications)? ®Yes ❑No Per 15A NCAC 02T.0105(c)(6),directly related environmental permits or certification applications must be being prepared, have been applied for,or have been obtained. Issuance of this permit is contingent on issuance of dependent permits(erosion and sedimentation control plans,stormwater management plans,etc.). 7. Does this project include any sewer collection lines that are deemed"high-priority?" ®Yes ❑No Per 15A NCAC 02T.0402,"high-priority sewer"means any aerial sewer,sewer contacting surface waters, siphon,or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. ➢ If yes,include an attachment with details for each line,including type(aerial line,size,material,and location). High priority lines shall be inspected by the permittee or its representative at least once every six-months and inspections documented per 15A NCAC 02T.0403(a)(5)or the permittee's individual System-Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 X. CERTIFICATIONS: I. Does the submitted system comply with 15A NCAC 02T,the Minimum Design Criteria for the Permitting of Pump Stations and force Mains(latest version),and the Graves Sewer Minimum Design Criteria latest version as applicable? ® Yes ❑No If no, for projects requiring a single variance, complete and submit the VariancelAlternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. APProval of the request will be issued concurrently with the aPProval of the Permit, and Projects reauirine a variance approval may be subject to longer review times.For Projects reguirine two or more variances or where the variance is determined by the Division to be a sienificant Portion of the Project,the full technical review is required. 2. Professional Engineer's Certification: Western Sewer System—Gravity Sewer, 1, Jeffrey W. Sweater ,attest that this application for Force Main,and Southside Pump Station_ (Professional Engineer's name from Application Item III I ) (Project Name from Application Item 11 1) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications,engineering calculations,and all other supporting documentation to the best of my knowledge. f further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minitnurn Design Criteria for Gravity Sewers(latrst version),and the Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains(latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation,or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed$10,000,as well as civil penalties up to$25,000 per violation.Misrepresentation of the application information,including failure to disclose any design non-compliance with the applicable Rules and design criteria,may subject the North Carolina-licensed Professional Engineer to referral to the licensing board.(21 NCAC 56.0701) North Carolina Professional Engineer's seal,signature,and date: CAROB SEAL i 056476 �• 9/27123 2 '; G INS •'•�i ��: %% __ tlt}11 3. Applicant's Certification per 15A NCAC 02T.0106(b): iIN Western Sewer System—Gravity Sewer 1, Allen Brooks Lockhart ,attest that this application for Force Main,and Southside Pump Station (Signature Authority Name from Application Item 13) (Project Name from Application Item 11 1) attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included,this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non-discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties,injunctive relief,and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed$10,000 as well as civil penalties up to$25,000 per violation. Signature: [rate: .z FORM: FTA 06-21 Page 5 of 5 Ytidllty State of North Carolina Department of Environmental Quality DWR Division of Water Resources 15A NC 02T.0300—SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources Raleigh Reg1Un�! Ice SSEA 04-16&SUPPORTING DOCUMENTATION Application Number: (to be completed by DWR) I. APPLICANT INFORMATION: 1. Applicant's name:City of Roxboro 2. Applicant type: ❑ Individual ❑Corporation ❑ General Partnership ❑ Privately-Owned Public Utility ❑ Federal ❑ State ® Municipal ❑County 3. Signature authority's name: Brooks Lockhart per 15A NCAC 02T 0106(b} Title: City Manger 4. Applicant's mailing address: PO Box 128 City: Roxboro State: NC Zip: 27573- 5. Applicant's contact information: Phone number:Q 36)322-6010 Email Address:blockhart_.cityofroxboro.com II. PROJECT INFORMATION: I. Project name: Western Sewer System-Gravity Sewer, Force Main and Southside Pump Station 2. Application/Project status: ❑ Proposed(New Permit) ® Existing Permit/Project 3. If a modification,provide the existing permit number: WQ0022241 and issued date: February 2003 4. If new construction but part of a master plan,provide the existing permit number: WQ00 5. County where project is located: Person 6. Approximate Coordinates(Decimal Degrees): Latitude:36.34923 -Longitude:-78.99170c III. CONSULTANT INFORMATION: I. Professional Engineer: Brian R. Houston License Number: 30226 Firm: LaBella Associates Mailing address:400 S.Tryon Street City: Charlotte State:NC Zip: 28285- Phone number: (7k4)941-2110 Email Address: bhouston@labellai)c.com IV. WASTEWATER TREATMENT FACILITY(WWTF)INFORMATION: 1. Facility Name: Roxboro WWTP Permit Number:NCO021024 Owner Name:City of Roxboro V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. Permit Number(s):NC 0021024(Connection to Existing WWTP} System Wide Collection System Permit Number(s): WQCS00048 Owner Name(s): City of Roxboro FORM: SSEA 04-16 Page I of 6 VI. GENERAL REQUIREMENTS I. if the Applicant is a Privately-Owned Public Utility,has a Certificate of Public Convenience and Necessity been submitted? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold,has a Developer's C)perational_Agreement_(FORM: DEV)been submitted? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners'Association,has an Operational Agreement(FORM: HOA)been submitted? ❑Yes [—]No ®N/A 4. Origin of wastewater:(check all that apply): ® Residential Owned ❑ Retail(stores,centers,malls) ❑Car Wash ® Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School/preschool/day care ❑ Medical/dental i veterinary facilities ❑ Swimming Pool/Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filtcr Backwash ® Businesses/offices/factories ❑Nursing Home ❑Other(Explain in Attachment) 5. Is/was an Environmental Assessment required under I SA NCAC 01 C? ® Yes ❑No If yes,submit the appropriate final environmental document (FONSI, ROD,etc.) 6. Nature of wastewater: 80%Domestic/Commercial %Other waste--specify: 20%Industrial(See 15A NCAC 02T.0103C29)) 7. Wastewater generated by project:4 500 000_total(2,160,000 additional)GPD(per 15A NCAC 02T.01 14) Hasa flow reduction been approved under 15A NCAC 02T.01 14(f)? [:]Yes ®No If yes,provide a copy of flow reduction approval letter 8. Summarize wastewater generated by project: Establishment Type Daily Design Flow"b No.of Units Flow gall GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total GPD a See I SA NCAC 02T .0114(b), (d),(e)(1) and(ex2) for caveats to wastewater design flow rates(i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified below shall be determined using available flow data,water using fixtures,occupancy or operation patterns,and other measured data. FORM: SSEA 04-16 Page 2 of 6 VI1. GRAVITY SEWER DESIGN CRITERIA- 15A NCAC 02T.0305: 1. Summarize Gravity Sewer to be permitted: Size(inches) Length(feet) Material 24 2,868 PVC&DIP 18 17,375 PVC&DIP V111. PUMP STATION DESIGN CRITERIA—02T.0305& MDC(Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: Southside Pump Station 2. Approximate Coordinates(Decimal Degrees): Latitude: 36.34923' Longitude:-78.99170' 3. What is the nearest 100-year flood elevation to the facility?604.1 feet mean sea level. Source: FEMA Is any of the proposed project located within the 100-year flood plain? ®Yes ❑No 4, If Yes,are the following items provided per 15A NCAC 02T .0305(e): Water-tight seals on all station hatches and manholes;and Control panels vents extend two feet above the 100-year flood plain elevation? ❑ Yes ®No ❑N/A If No,what measures are being taken to protect them against flooding? Manhole rims are at least 2 feet above the 100- ear flood elevation and pump station hatches and controls are all located outside of the 100-year flood plain 5. Finish grade elevation of the pump station: 607.50'(Ton of Pump Station Lid 608.50') 6. Design flow of the pump station: 2.016 millions gallons per day(firm capacity) 7. Operational point(s)of the pump(s): 1400 gallons per minute at 218 feet total dynamic head(TDH) 8. Number of pumps provided:2 9. Number of pump cycles at average daily flow: Pump are VFD-driven so flow matching(continuous-no cycles,except at flows below minimum 5.ingle-pump rate). Pump station has been sized using MDC for Pump Stations and has been sized in order to prevent sewage_from going septic cycles per hour 10. Power reliability in accordance with 15A NCAC 02T.0305th)(1): ® Standby power source or pump with automatic activation and telemetry- 15A NCAC 02T.0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation,quick-connection receptacle and telemetry- 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry- 15A NCAC 02T.0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant(draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: SSEA 04-16 Page 3 of VIII. PUMP STATION DESIGN CRITERIA(continued) 11. Summarize the pump station design elements: Design Element Plan Sheet Specification Reference Reference Power Reliability Source and Associated Elements E2, E3 260000 Screened Wet Well Vent D110 - Check Valves,Gate Valves,etc. D111 400554 Control Panel E2,E3,E4 260000 Restricted Access Elements(Fence,Wet Well Lock,etc) U312 Audible and Visual Alarms E4 Telemetry/SCADA E4 Level Controls DI 10, E4 Weatherproof Sign with Required Information Air Relief Valves See Drawings 12. Summarize the force main to be permitted: Size(inches) Length(feet) Material High Discharge Pump-Off Elevation feet Elevation feet Elevation(feet) 16 23,118 PVC&DIP 790 741 598.1 13. Air release valve station locations per l 5A NCAC 02T.0305(i): Air Release Valve# Station Plan Sheet Reference 1 35+15 U204 2 74+65 U208 3 153+37 U215 4 195+85 U219 5 228+40 U222 FORM: SSEA 04-16 Page 4 of 6 IX. SETBACKS&SEPARATIONS—(02B.0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T.0305(1)& ® Yes ❑No ➢ 15A NCAC 02T.0305 contains minimum separations that shall be-Provided for sewers stems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical-water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical-reclaimed over sewer 18 inches Reclaimed water lines horizontal-reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS(except WS-I or WS-V), B,SA,ORW,HQW,or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment,or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage s stems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches ➢ 15A NCAC 02T.0305(&)contains alternatives where separations in 02T.0305(fl cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage ➢ If noncompliance with 02T.0305(f)or W, see Section X of this application 2. Does the project comply with separation requirements for wetlands?(50 feet of separation) ® Yes ❑No ❑N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑No ❑N'A ➢ This would include Trout Buffered Streams per 15A NCAC 2B.02Q2 4. Does the project require coverage/authorization under a 404 Nationwide or ® Yes ❑No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(cX )(additional permits/certifications)? ® Yes [:)No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for,or have been obtained. Issuance of this permit is contingent on issuance of dependent permits(erosion and sedimentation control plans,stormwater management plans,etc.). 6. Does this project include any sewer collection lines that are deemed"high-priority?" Per 15A NCAC 02T.0402, "high-priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ® Yes ❑No ➢ If yes, include an attachment with details for each line, including type(aerial line,size,material,and location). High priority lines shall be inspected by the permittee or its representative at least once every six-months and inspections documented per 15A NCAC 02T.0403(a)(5)or the permitee's individual System-Wide Collection permit. FORM: SSEA 04-16 Page 5 of 6 IX. CERTIFICATIONS: I. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria For the Pennittine of Pump Stations and Force Mains(latest version),and the Gra vity Sewer Minimum Design Criteria latest version as applicable? ® Yes ❑No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: I, Jeffrey W. Sweater attest that this application for (Professional Engineer's name from Application Item III.1.) Western Sewer System - Gravity Sewer Force Main and Southside Pump Station (Facility name from Application Item II.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations,and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with this application package and its instructions, as well as all applicable regulations and statutes. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed$10,000,as well as civil penalties up to$25,000 per violation. CAR North Carolina Professional Engineer's seal,signature,and date: .,goes*,.D4,��i, sees S S losses q. so • 0 • I t W. F 3. Applicant's Certification per 15A NCAC 02'r.0106 b : 1, T{.A anyckl 4pe_&A.4— . N attest that this application for (Signature Authori s name& title from Application Item 1.3.) (Facility name from Application Item 1I.1.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that any discharge of wastewater from this non-discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief,and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE - In accordance with General Statutes I43-215.6A and 143-215.6a, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed$10,000 as well as civil penalties up to S25,000 per violation. L. lJg Signature: Date: 23 FORIM: SSEA 04-16 Page 6 of 6 NC Dept. of Environmental Quality Feb 9 2024 Raleigh Regional Office State of North Carolina Department of Environmental Quality Division of Water Resources Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-23) Entity Requesting Allocation: City of Roxboro Project Name for which flow is being requested: Western Sewer System More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Roxboro WWTP b. WWTP Facility Permit#: NC 0021024 All flows are in MGD c. WWTP facility's permitted flow 5 MGD d. Estimated obligated flow not yet tributary to the WWTP 0.049 M_GDc,____ e. WWTP facility's actual avg. flow 2.03 MGD f. Total flow for this specific request 0 MGD g. Total actual and obligated flows to the facility 2.079 MGD h. Percent of permitted flow used 41.55% I1. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Avg. Tributary Flow Plus (Name or Permit Capacity,* (Firm/pf), Daily Flow, Daily Flow, Obligated Available Number) No, MGD MGD MGD MGD Flow Capacity*** Southside WQ0022241 1.517MGD 0.607MGD 0.300MGD 0.012MGD 0.312MGD 0.295MGD Footnote 1: Based on pump run times that were monitored every 10 seconds from 112612021 to 2/2/2021 to determine pumping rates when the Duncan PS is operating. Note, the Southside PS does not have any flow or pump runtime meters installed,as discussed within the Basis of Design Technical Memo. The pump capacities at the Southside PS are impacted bythe Duncan Rd PS due to the stations currently sharing an undersized combined force main. Thus, even if run time meters were installed, estimating flow at this station over an annual period would be very difficult and inaccurate. *The Firm Capacity(design flow)of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. **Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor(pf)not less than 2.5,per Section 2.02(A)(4)(c)of the Minimum Design Criteria. ***A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is<0. Downstream Facility Name(Sewer): City of Roxboro Collection System Downstream Permit Number: WQCS00048 Page 1 of 8 FTSE 10-23 III. Certification Statement: I Allen Brooks Lockhart certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. 2/9/2023 Signing QoTcial Signature Date City Manager,City of Roxboro Title of Signing Official Page 2 of 8 FTSE 10-23 Emergency Lift Station Contingency Plans City of Roxboro, North Carolina Lift Stations Master List Station # Address Status Comments 1 49 362 Burlington Rd Complete 2 Brooks 1259 Hurdle Mills Rd Complete 3 Arrowood 405 North Park Dr Complete 4 Duncan 1324 Billy Hicks Rd Complete 5 Southside 357 Patterson Dr Complete 6 Crown Crafts Complete Needs Address 7 GKN Complete Needs Address 8 Cedar Ride 333 Laura Lane Complete 9 Williams Rd 787 Doctors Court Complete 10 Helena 400 Personage Rd Complete 11 Stories Creek 1133 Stories Creek Rd Complete F 1 � hrl h1 1 n /yd p �lid IeY UN is l O C�1 fyeo Rd f0o.ppo ! �^ Coutirr cWh Wtchefl KA Lord chun.l,Ka CITY OF ROXBORO WWTPC,,,cl +r i�Sre� v r b�'rc F Ro .T' n G f Cv O E C JO PQ r(a : 'apt' a9 0 a � c4 ¢� 2 PROPOSED GRAVITY SEWER G,o h bra lodd Z hngre4er �a a `� ' e� �\� 5 �y (116 0t = 19 Slats H d Ada y:d D 32 qoa-a D `°oC �c RolerlsonRd i FORCE MAIN TIE-IN = TO GRAVITY SEWER Rcxboro zed a l J� hhrun:aln Ka E J enai Go°v"Cbwch Rd a p 'Pd 3, ,y a7 t y`e�� a p,p Af'c'rn_,1r RO Deep Cfe" yCnlrl., PROPOSED FORCE MAIN ram? C O Y r') rl 12,1 W w erne tid SOUTHSIDE PUMP STATION 3 (EXISTING AND PROPOSED) " In z o a � r z irV' T Legend i � t 2 _ e �o "� y�'R� � � s d Proposed Forcemain r g w A 4"Oc9- ° ?a N yFlarR Proposed Gravity Sewer In 0°ttc Fo tier ? N aid¢ w w N �DeCs ao sell I+ononl,}! °tK 00 2.800 5,600 Feet u: al 0 0 Sanitary Sewer CLaBelLc"a Western Sewer System Site Plan City of Roxboro La6ella Project No: 2201369 Date: September 2023 FIGURE 1 r a w LaBeLLa roweteo ray partnelship. City of Roxboro On and Adjacent 14 14 TO.,"aCI Tax Parcel Map Roxboro Western 1411 Sewer System Roxboro, NC clAT top;it tF��,°4 N 1333 N -- 7 REael,- 0 1,OOD 2,000 Feet t- 1398 l 1 1 ------__ c ` 1 inch-2,000 feet ---- 1334 ` Legend n� 5 - OStudy Area JFF90 1 5, =Tax Parcel Map 1. 6 XX-X Parcel Number � 1 33 5 XX-X Parcel Impacted by Project n �!� z 133 55 s rR°yroe;rr. n w Y 37E� xO RTN atpOE CIR 134 t C y 44 0 Y � „ i M! ■�RlflG G. C f 1342 f R \ 1 Sources: A 134 7 1 I n 1.Study Area:Created by La Bella using information 12 eim., provided try the client. �sr _ 2.Basemap:ESRI USA Topo Map(Updated:2020) in reference to USGS Topographic Greenwood Quadrangle)2022). Geographies,CNES/Airbus DS.USDA.USGS 28 1 n 4 Parcel Location Map A �'`enr tt oa 127 AVE x. 12 9Eoa Q 1 f'CIR Husk Sarr t"y �a gym,; Page 1 of 2 �k 123 �� 1 Matchline-Refer to Page 2 LaBella Project No:2201369 Date:July,2023 '.KAM Reviewer EP K V rJ W W A N � l W i J CJI A ^4 J � OJQ7 Oa 1 CO N � i m. / CO., N J A `Y N J U Q T(i b N / i N W f'N - - O f►� x co n Coor Opr '1'F a o N co N Ml OD O m a � O 1 N •`'b r.n.nAa a�0 x n O G etl a 0 x tr y L+ in .: 7f ar i i O O 4 p y n O M 1� aan�� rye ~pP Ooo� wn��5v�c � a� t9 C� agm m v x ► OQ A `<a CD cr k a} CD N Ll VCR 'D Z (D CD3 X O n o fa CD O D fn�q a a C w n � N n N 8 D g C-) cr a O T! fD (D O y O r+ ?q U L O y♦ � ` O N O o GEC c O Z M ^► � CV m C a w f�D N 3 CD CD N d m R � CA Project & Existing Permit Narrative - SEAL - Fast Track Sewer Extension Application = i NCDEQ— Division of Water Resources %056476 NE� Reference: Western Sewer System City of Roxboro, Person County 12/15/2023 LaBella Commission Number: 2201369 Last Revised: 12/15/2023 Project Summary The proposed project is located in western Roxboro, Person County, North Carolina. The project consists of construction of approximately 23,118 LF of 16-inch diameter force main, 17,375 LF of 18-inch & 2,868 LF of 24-inch gravity sanitary sewer, and replacement of the Southside Pump Station. The 16-inch diameter force main will transition to an 18- inch gravity sanitary sewer line at a manhole near Semore Road. The overall project area is 31.4 acres, which includes all permanent and temporary construction easements, and construction staging areas for the project. The new sanitary sewer force main and gravity line will be constructed either within new easements or within the road-right-of-way. Easements have been obtained where necessary along the entire project. Included with the submittal are 70 drawing sheets of plan and profile views for the sewer lines and Southside Pump Station replacement. Need for Project The city of Roxboro is growth-limited due to existing sewer limitations, the current Sewer Outfall is undersized for the existing conditions. The Sewer Outfall becomes surcharged during wet weather conditions, leading to sanitary sewer overflows. These issues need to be addressed either by increasing the capacity of the sanitary sewer line or reducing flows. This project is necessary to upgrade the outdated and undersized equipment. See attached Technical Memo for additional details. Existing Permits Permit No. WQ0022241, dated February 3, 2003 was issued to the City of Roxboro for the construction and operation of Southside Pump Station and Wastewater Collection System Extension. This permit is effective from date of issuance until rescinded and granted the City of Roxboro permission to construct and operate a 950gpm pump station with duplex pumps, on-site audible and visual high water alarms, manual transfer switch, portable generator quick-connect receptacle and telemetry system to serve as part of the Southside Pump Station project. Existing Permits (con't) Permit No. WQCS00048, dated June 15, 2015, has been issued to the City of Roxboro for the construction and operation of the referenced wastewater collection system described above. This permit is effective from November 1, 2015, until October 31, 2023. Copies of the two above permits have been included in this application. Compliance with Minimum Design Criteria / 15A NCAC 2T Regulations The proposed City of Roxboro Western Sewer System has been designed in compliance with the NCDENR Minimum Design Criteria for the permitting of Gravity Sewers (MDCGS), and Pump Stations and Force Mains (MDCPS-FM 03/08). The design of the proposed 24-inch diameter gravity sewer aerial crossing over Marlowe Creek is shown on Sheet U101 and construction details 8 and 9 on Sheet U406 (see attached), was the NC DEQ's area of most concern for this project being able to meet the MDCGS. The following is a review of the MDCGS Section V.F for aerial crossings, shown in green text, and a summary of how this project complies with it: F. Aerial Crossings 1. Proper joint technology, such as flanged or restrained, adequate supports to prevent excessive flex on, or a combination of both shall be provided for all aerial pipe crossings. Supports shall be designed to prevent frost heave, overturning, and settlement. Proposed Project Compliance Measure: The structural design of the aerial crossing has been thoroughly analyzed and resulted in the development of the plan and profile design on sheet U101 and construction details 8 and 9 on U406. The footer for the proposed reinforced concrete piers extends well below the maximum recorded frost levels for the area and has a 30 SF minimum footprint footer supporting each pier. Additionally, long-span ductile iron pipe with a maximum thickness class of CL 56 is specified to ensure the protection of joints and pipe walls from debris that could be transported within the creek during flood events. 2. Precautions against freezing, such as insulation and increased slope, shall be provided. Expansion jointing shall be provided between above ground and below ground sewers. Where buried sewers change to aerial sewers, special construction techniques shall be used to minimize heaving. Proposed Protect Compliance Measure: The current slope is the minimum recommended flow to achieve a 2 ft/s scour velocity is 0.081%. The proposed aerial crossing was increased to 0.100% slope to provide a minimum velocity of 2.5 ft/s, which is 25% faster than the minimum slope requirements, to reduce the crossing's freeze potential. Bends or fittings that could slow the flow of water in certain areas of the exposed pipe were also eliminated to reduce freezing potential along the wall of the sewer main. The section of gravity sewer is proposed to have a 1,400 gpm pump station feeding it and is close to its discharge point at the WWTP. Thus, this section of the sewer main is expected to consistently experience heavy wastewater flows, which will prevent freezing from being able to occur due to only being exposed to the aerial crossing/open air for 10.6 seconds at design flows. 3. For aerial stream crossings, the impact of flood waters and debris shall be considered. The bottom of the pipe should be placed no lower than the elevation of the 25 year flood. Ductile iron pipe with mechanical joints shall be required. In the event that the 25 year flood elevation can not be determined or the proposed gravity sewer must be placed below the 25 year flood elevation, a letter shall be provided by the applicant upon certification stating: "Regular and proper inspection and maintenance of the aerial crossing shall be provided to insure that the creek/stream flow is not impeded and that no damage will be caused to upstream or adjacent properties." Proposed Project Compliance Measure: As discussed above, Long Span, CL-56 thickness rated, Ductile Iron pipe was forthe aerial crossing to further eliminate the potential of an unauthorized release in the system. Which happens to be the strongest Ductile Iron Pipe commercially available for utility construction, as are the specified mechanical joint types for this crossing. The proposed aerial crossing could not be raised above the 25-year flood elevation without requiring the construction of a second/intermediary pump station or gravity siphon, which both have a greater risk of failure and impacting the environment and local waterways than the 26.5 ft of exposed aerial pipe crossing. Thus, the Applicant (City) proposes the following to meet MDCGS V.F.3 and allow the FTA permitting process to be utilized for this project: • Upon the engineer's certification of completion at the end of the project before DEQ authorizes the new sewer system for operation, the Applicant/Owner/City will provide a letter on their letterhead stating: "Regular and proper inspection and maintenance of the aerial crossing shall be provided to insure that the creek/stream flow is not impeded and that no damage will be caused to upstream or adjacent properties." LaBeRa Powered by partnership. 'i ; �'I J •;••��: �(( / 400 S. Tryon Street, Suite 1300 • ti'' �� Il "� :•L`•' ��' I ; Charlotte, INC 28285 �� qi 1,i •; i I )� / 704-376-6423 N.C. License # C-0430 ETLAN label) co TOP % ( apc EX SSMN i �• 1 •. .••• • I , r ' BOTTOM OF BOX 478.09' \� /I i •;;�,•;;,•••, ' �l 469,68' �� \ i•I I i 1 I i.,.• y�/ I i I ��I �` ` ! ���(;: ;;•• i // ) S'MH SkRUCTURE�IQ_ _ F T / I^ 1 �, / I i 2+89 -i SON Ex wooDs��; 1 \' , 11 ; ;:• I ; `RIM=475.02 'a I % _____� ') � i •f;;,l i�i � � i N�INV=467,78�, EX WOODS - �, I/ a ,.•' , A `� I W NJV�46ZS8 I a "'�100YRFLOOD- f1 �I :� ' �`.�`�\ --�_' o` �\�\P `OC`G K. 27° -_- - 5 F o"A' R�� P ASSOC/qI \� 1 �,• P g551" _ _ �\ `'� z289.t• 1 , '. A��� IMITSOFDISTURBANCE SEAL CERT. CHIP F. LOFTON AND WIFE,�dA 056476 szsa A �1 7rV DB 1046 PG 21 PB 13 PC 12 °!.,�� .•`°���� '9acorre.N . EX.SS MH 0 1 TEMPORAR�STONE - -- cy (� WE ��___ L .......„8/4/231 TOP=478.88• �x � �1 „� OUTLET(TY ,, INV=470.21.8"(NE 1 \ SEE DETAIIgO2 \ 'a \By. ------ INV=467.00• 30"(SE) 4 `� MARLOWE$1 � � I TEMPORARY SEDIMENT � '00 O 1 \\��, C ��--TENCE(TYP.)SEE BET.2/U401 888°54'oa.9rw ,\ PROP.INV=467,50' 24"(SW) CREEK CROSSIN ( �) xs4a.6a ` '$" i S 02023 LaBelle Associates 8F�DlP (AERIAL) >� \ 48 EX SS 100 YR FLOOD 00 118° TOP=480 INV=470.78'8••(NE `� INV= 470.76'8"(SW) APPROXIMATE LOCATION OF EXIST.SEWER TEMPORAR STRUCTION �P,I�RANCE.SEED . 402 q/G 1 ) L V I ^ HSTRU URE-102 S�M CT \ / EX MOBILE \ 1 �l / \ , ' Q 1 � / V � 5'DIA MH HOME NFS , i—�� 1�� STA.6+34 - 7 itOXBOgO <�F I_-AM9=474.9g \ i/ NOTITs CAROLINA 0 TR RO ND / E INV=68.11 / -�— p S6gCT CGN NO ` ` \ ��I _\_� \ SW INV=4TiB317 / 2S6 \ Ilk CITY OF ROXBORO WESTERN SEWER SYSTEM - GRAVITY SEWER, FORCE 490 490 MAIN & SOUTHSIDE PUMP STATION X.6 D114 SS H +U7 iI I IV=46 00" 0°SE) o 111111 V=467.0'2"(S NO I DATE I DESCRIPTION: REVISIONS PROJECT NUMBER: 480 480 2201369 II _ DRAWN BY: EP/JUR REVIEWED BY: BRH ISSUED FOR: PERMITTING RE RI EXI T.M H LE 10-YE RROOE PLAN E STI G GI iOU D 3 — DATE: 08/04/2023 IST.MAN OL — DRAWING NAME. 470 470 - PROPOSED GRAVITY E SEWER LINE ±4.16' 4"C 00 C 0.1 C-REE K C OSSI G. SO FRO I OF REI K 31. E 3 EM EDT)M INTAN STI CO TO RS SE ET. _4 6 _ STA. 0+00 TO 7+00 ±48 24"ON SPA DI @ .10 - 3OmP 0 IL DRAWING NUMBER'. o 460 E -4 460 -0+75 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 U 101 �ry MIN.2'CLEAR OF TYP.2'CLEAR OF LaBeRa PROTECTED PAVEMENT* 0.3 STRUCTURE* 1"DOME-FILL BOLLARD Powered y partnership. WITH CONCRETE. 400 S. Tryon Street, Suite 1300 3'-3"FOR 26'MAX.HT. Charlotte, NC 28285 4"x 1/2'H.D.GALV. 704-376-6423 STL STRAP 3'-0"FOR 24' .HT. PAINT COMPLETED 2'-9"FOR MAX22'MAX.HT. BOLLARD YELLOW 7"(MIN.) N.C. License # C-0430 4'-2"MIN. 2'-6"FOR 20'MAX.HT. abellapc.com PIPE O.D.+24' 2'-3"FOR 18'MAX.IT. 2'-0"FOR 16'MAX.HT. o 1'-9"FOR 14'MAX.HT. 6"DIAMETER 1'-W FOR 12'MAX.HT. SCHEDULE 40 , 1'-3"FOR 10'MPX.HT. 4 STEEL PIPE T C-O 1'-0"FOR 8'MAX.HT. NOTES: �I^J 1. ALLCONCREFEISTOBE3,750P.S.1. °' ° °CONCRETE• 3' 2. MAXIMUM HEIGHT OF REINFORCED ZVCROWN WALL 1"DIA.GALV.STL. CONCRETE PIERS IS 26'-0', , f ANCHOR BOLTS 3. FOOTING THICKNESS IS TO BE EQUAL m NUT58WASHERS 4" 4 S OOE PARALLEL BE BUILT WITH LONG D GRADE SURFACE A A 3 3 CL 5. PIPE IS TO BE SET��IN PIER AND) #3 TIES@12'O.C. 12 PROTRUDING ABOVE THE PIER.WHEN III- PIERS ARE PLACED PARALLEL TO THE #6 ° �O 10'O.C. V CHAMFER FLOW OF THE CREEK AND PIPE IS ON I I I 3 CL ASKEW WITH THE PIER,HOLDING ALL CORNERS POLYPROPYLENE PLASTIC 3'-0' 3'-0" mP') STRAPS MAYBE PLACEDATRIGHT T ANGLES TO THE PIPE,PROVIDING THE _ ° . CONCRETE FOOTING SOLID OUTER SHELL „ _ LAP REINF.30' ANCHOR BOLTS ARE NOT SET WITH A - 4 ,.`P'lN CAR x* P,sE POROUS MASS v -IIIII IF SPLICE IS CLEARANCE OF LESS THAN 2-INCHES •rpFEs tO -ILL - REQUIRED TO THE PIER SURFACE. °* :p -I 12" 12• *UNLESS OTHERWISE c SEAL _moo CERT.No.`Os 6. NO REINFORCING STEEL IS TO BE PLACED WITH A CLEARANCE OF DIMENSIONED 05647p6 529p4 LESS THAN 3-INCHES TO THE PIER 01T .r 6 No.3 DEFORMED SURFACE. STEEL RODSyy, ��.``�, nq N. 7. DESIGN SOIL BEARING PRESSURE IS Corre, �;F.G @ E12-O.C. 2,500 P.S.F.MINIMUM AND SHALL BE IA. umx EACH WAY 3"CL. FIELD VERIFIED PRIOR TO PIER 18"D „`8/4/23� e CONSTRUCTION. MIN. SECTION A-A 3 CL 3"CL. 9 Reinforced Concrete Pier Detail 5 Bollard Detail ©2023 LaBelle Associates 2 Manhole Step 10'MAX.C-C IO'MAX.C-C 10'MAX.C-C GATE MINIMUM ZONE OF MECHANICALLY RESTRAINED JOINTS .� (SEE NOTE 2) \ F LONG SPAN DUCTILE IRON PIPE TERMINAL POST x " " LINE POST BARBS GATE POST 2"MINA.O.D. \ POST CAP _3y'MIN.._._._. 7'MIN,_,_,_ _,_,_,_,_, ,_,_ _ 18" 45'-0'MAX. 18" THREESTRANDSBARBED WIRE (LORBO$O CONTRACTOR SHALL SET NO4tu C4ROLI1114 IT-6" MANHOLE RIMS FLUSH WITH 3/16"x3/4"STRETCHER 15i$TOP RAIL FINISHED GRADE IN LAWNS, FRAME AND COVER SPAN o BAR NOTE: N.C.D.O.T.R/W AND PAVED SEE DETAIL C4/C1.03 rr��,,�� PROVIDE CFD APPROVED AREAS. U 1'tlMIN.O.D. N0.9 TIE WIR RAPID ENTRY"KNOX BOX" 71 -p f BRACE @ 24"O.C. FOR FIRE DEPT.ACCESS z � 4 2'GALV. PRECAST CONC. WIRE MESH GRADE RINGS Z 4 Ttl DIA TRUSS RO NO.7 GA. 8" 24" 81. REINFORCED CONCRETE PIER REINFORCED CONCRETE PIER W/TURNBUCKLE TENSION WIRE ' bO CITY OF ROXBORO SEE DETAIL 9/U406 SEE DETAIL 9/U406 DEPTH TO BE DETERMINED IN FIELD BY ENGINEER BASED ON SOIL CONDITIONS NOTES o WESTERN 1 ALL RIGID PIPE CROSSINGS AT CREEKS SHALL USE LONG SPAN DUCTILE IRON BARBS GALV O SEWER SYSTEM - CL-56MINIMUM THICKNESS CLASS PIPE WITH MECHANICALLY RESTRAINED JOINTS. z a PIPE z ,'� 2.MECHANICAL RESTRAINED JOINTS SHALL EXTEND A MINIMUM OF ONE FULL STICK Z i f NO.7 GA.HOG z Z OF PIPE PAST THE REINFORCED CONCRETE PIERS. E a RINGS @ 24'O.C. E O AGGREGATE G GRAVITY SEWER, FORCE g Typical Rigid Creek Crossing Detail NOT LESS THAN IJ. 2 MIN U 3 SEE DETAIL STEP o - MAIN & SOUTHSIDE yp g g 4x O.D.OF -o POST(12"MIN) - C5/C1.03 PUMP STATION CONC. I�NOT LESS THAN @ m FOOTING 12"MIN. I X 4 x O.D.OF POST " J / 112"MIN) N ti + O (� w z 4 Chain Link Fence and Gate Detail DIAMETERAC1.04 FIED � � 1 L L l� 1' Detail ON Bl/C1.04 O w NO: DATE: DESCRIPTION: PROVIDE 4-1"DIA.VENT HOLES INV.ELEV. REVISIONS III Ii! STEPS@ 90°OFF ZPROJECT NUMBER INLET ON SIDE OF ¢ O 2201369 TOP OF COVER LARGESTA GLE > U 2'MIN.(95%STD.PROCTOR) c/�� 3 "' DRAWN BY: (MACLASS))SAS BACK IOILS OF ASTM 2321 ✓ 1"DIA.HOLES IN m REVIEWED BY: EP/JUR III III �� �W,�INIMUM FLANGE @ 90° BRH MAY USE NATIVE SOILS OF ISSUED FOR: ASTM 2321 CLASS S) � PERMITTING _ (OR CLASS IA OR IS)ABOVE THE SPRINGLINE. IIIII IIIII III BOTTOM OF COVERCAREFULLY COMPACTED BACKFILL N _ CAREFULLY COMPACTED BACKFILL CAST-IN-PLACE GATE: 95%STANDARD PROCTOR DENSITY 95%STANDARDPROCTOR DENSITY (3)#4 BACONCRETE INVERT 08/04/2023 III- (TAMPED IN 6"LAYERS) AY*CLASS III NOT ALLOWED IN DEPTHS OF COVER 120' AVERAGE WEIGHT CAST-IN-PLACE WATERTIGHT 4"THICK MIN.COMPACTED DRAWING NAME: FLEXIBLE PIPE SEALS OR SLEEVES CRUSHED STOME LEVELING -11 o III RING 1901b5. COURSE _ COVER 1201bs. `= )III � IIIII V V HAUNCHING#57 WASHED STONE TYPICAL ALL PIPE OPENINGS J ✓ L v v V IIIII COMPACTED GRANULAR MATERIAL SPRINGLINE - v L GRANULAR MATERIAL 95%STANDARD SECTION ON GRAVITY SEWER I/2 D l L - PROCTOR DENSITY 3�4.. 23 4" 310 lbs. > �. ./ 1/4 D(4"MIN.) 1..2 2 3/8 a 1/4 D MIN. - �IT-iTi= =iTl-iTi=i �_� =i iIT =1TI=iTI=iTI=iTI=i =1 1=, i= GENERAL NOTES: AND SITE DETAILS s I 3 1. ALL MORTAR JOINTS TO BEY2"+/-Y8". '€d CLASS B /� n C C• O y8" 3z A' Q 2. ALL CONCRETE TO BE 3,600 P.S.I. 8 E COMPACTED GRANULAR BEDDING NOTE: li A J J U 3. FORMS ARE TO BE USED FOR CONSTRUCTION OF THE BASE. �y LOAD FACTOR 1.9 INSTALL ALL PVC GRAVITY COMPACTED GRANULAR BEDDING 4. PRECAST MANHOLE COMPONENTS SHALL MEET REQUIREMENTS OF ASTM C478 SEWER BEDDING PER DETAIL 2 4" m� LOAD FACTOR 1.9 43�8„ � 5. MANHOLES OVER 3'-6"IN DEPTH SHALL BE PROVIDED WITH STEPS 12-INCH ON CENTERS. c o 241/9" 6. HOLES REQUIRED FOR L.P.S.OR FORCE MAIN CONNECTIONS SHALL BE PRECAST AT TIME OF DRAWING NUMBER: MANUFACTURE OR CORE DRILLED.CONNECTION SHALL BE SEALED WITH A SYNTHETIC RUBBER 33v4" INTERLOCKING MODULAR MECHANICAL SEAL. Standard Bedding Details For Sanitary Standard Bedding Detail For PVC 7. ALL PRECAST MANHOLES IN NCDOT ROW SHALL BE NCDOT APPROVED. 4 0 E r '� Sewer & Storm Drain Pipes 6 Sanitary Sewer Pipe 3 C.I.M.H. Frame & Cover 1 Precast Manhole Project & Existing Permit Narrative Fast Track Sewer Extension Application NCDEQ— Division of Water Resources Reference: Western Sewer System City of Roxboro, Person County LaBella Commission Number: 2201369 Proiect Summary The proposed project is located in western Roxboro, Person County, North Carolina. The project consists of construction of approximately 23,118 LF of 16-inch diameter force main, 17,375 LF of 18-inch & 2,868 LF of 24-inch gravity sanitary sewer, and replacement of the Southside Pump Station. The 16-inch diameter force main will transition to an 18- inch gravity sanitary sewer line at a manhole near Semore Road. The overall project area is 31.4 acres, which includes all permanent and temporary construction easements, and construction staging areas for the project. The new sanitary sewer force main and gravity line will be constructed either within new easements or within the road-right-of-way. Easements have been obtained where necessary along the entire project. Included with the submittal are 70 drawing sheets of plan and profile views for the sewer lines and Southside Pump Station replacement. Need for Project The city of Roxboro is growth-limited due to existing sewer limitations, the current Sewer Outfall is undersized for the existing conditions. The Sewer Outfall becomes surcharged during wet weather conditions, leading to sanitary sewer overflows. These issues need to be addressed either by increasing the capacity of the sanitary sewer line or reducing flows. This project is necessary to upgrade the outdated and undersized equipment. See attached Technical Memo for additional details. Existing_Permits Permit No. WQ0022241, dated February 3, 2003 was issued to the City of Roxboro for the construction and operation of Southside Pump Station and Wastewater Collection System Extension. This permit is effective from date of issuance until rescinded and granted the City of Roxboro permission to construct and operate a 950gpm pump station with duplex pumps, on-site audible and visual high water alarms, manual transfer switch, portable generator quick-connect receptacle and telemetry system to serve as part of the Southside Pump Station project. Existing Permits (con't) Permit No. WQC500048, dated June 15, 2015, has been issued to the City of Roxboro for the construction and operation of the referenced wastewater collection system described above. This permit is effective from November 1, 2015 until October 31, 2023. Copies of the two above permits have been included in this application. 0 LaBeRa Powered by partnership. NC Dept of Environmental Quality September 27, 2023 North Carolina Department of Environmental Quality SEP 2 9 2023 Division of Water Resources Water Quality Regional Operations Section Ms. Elaine Wild Raleigh Regional office 3800 Barrett Drive, Raleigh, NC 276og (919)-791-4200 Reference: Western Sewer System City of Roxboro, North Carolina LaBella Commission Number: 2201369 Subject: Western Sewer System - Gravity Sewer, Force Main, and Southside Pump Station Extension Application Please find attached the following requested information for the above-referenced project to comply with NCDEQ Fast Track Application submission requirements: 1. Fast Track Application Instructions/Checklist(3 pages) 2. Fast Track Application (5 pages) - Draft(not executed by the Owner) 3. USGS Site Map(1 page) 4. Project & Existing Permit Narrative(2 pages) 5. Existing Permits (17 pages) 6. Impacted Properties Map and List(3 pages) The following item(s)will be submitted under a separate cover letter directly from the Owner to NCDEQ 1. Fast Track Application (5 pages) - Fully Executed Original LaBella previously submitted a Standard Sewer Extension Application package that included the following Documents, which NCDEQ should still be in possession of: A. Fee Assessment (Check for $480.00) B. Technical Memorandum (so pages) C. Sewer System Extension Application Instructions/Checklist (4 pages) D. Sewer System Extension Application (6 pages) E. Flow Tracking for Sewer Extension Applications(6 pages) F. Technical Specifications (493 pages) G. Full-size project plans (70 sheets) 400 S Tryon Street, Suite 1300 I Charlotte.NC 28285 p 704-376-6423 1 f 704-332-6177 vwvw.labellapc c ,i i i The proposed project is located in Western Roxboro, Person County, North Carolina. The O proposed project consists of approximately 3.8 miles of 18' and 24" gravity sewer, approximately 4.3 miles of 16" sewer force main and modifications to the Southside pump station. The Southside pump station is proposed to have a capacity of 1,400 gallons per minute(gpm). The project contains one aerial crossing that cannot be set above the 25-year flood elevation and will require permanent disturbance of wetlands to install the new gravity sewer system. LaBella has submitted a Jurisdiction Determination and Chapter 401/404 permit submission package for review and approval by NC DEQ to meet the minimum design criteria requirements. NCDEQ assigned the permit submission package an action ID of SAW-2023- o18o6 and forwarded it to Rachel Capito at DEQ for further processing on 9/8/2023. Thank you for your time and please do not hesitate to call me with any questions or comments regarding the attached or the project in general (Direct: 941-374-393o, Email: isweatenajabella ce com) We look forward to your comments and subsequent approval. Respectfully submitted, LaBetLa Associates Jeffrey W. Sweater, PE Senior Project Manager Y\2201369 City of Roxboro Western Sewer System\CFile\Ph2-5\oio-Rev-Approvals\NCDEQ-ESC O 2 OF IArFR Michael F. Easley,Governor v0� QG William G_ Ross Jr., Secretary r North Carolina Department of Environment and Natural Resources O < Alan W. Klimek, P.E.,Director Division of Water Quality February 3, 2003 James Freeman, City Manager City of Roxboro Post Office Box 128 Roxboro, NC 27573 Subject: Permit No. W00022241 City of Roxboro Southside Pump Station Wastewater Collection System Extension Person County Dear Mr. Freeman: In accordance with your application received January 16, 2003, we are forwarding herewith Permit No. WQ0022241, dated February 3, 2003, to the City of Roxboro for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system-wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2H. .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina-licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as-constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina-licensed Professional Engineer to the licensing board. In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Roxboro for the construction and operation of a 950—gallon per minute pump station with duplex pumps, on-site audible and visual high water alarms, manual transfer switch, portable generator quick-connect receptacle and telemetry system to serve as part of the Southside Pump Station project (pump replacement), with no additional discharge of collected domestic wastewater into the City of Roxboro's existing sewerage system, pursuant to the application received January 16, 2003 and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Non-Discharge Permitting Unit Internet httpWh2o.enr.state.nc.us/ndpu 1617 Mail Service Center, Raleigh,NC 27699-1617 Telephone (919)733-50B3 Fax (919)715-6048 DENR Customer Service Center Telephone 1 (800)623-7748 An Equal Opportunity Action Employer 50%recycled/10%post-consumer paper Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. , The sewage and wastewater collected by this system shall be treated in the City of Roxboro Wastewater Treatment Facility (Permit No. NC0021024) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Kristin E. Miguez at (919) 733-5083 extension 524. Sincerely, for Alan . Klim k, P.E. cc: Person County Health Department Raleigh Regional Office, Water Quality Section (WWTF Permit No. NC0021024) Pease Associates Central Files 14PDU Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system-wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed prior to January 1, 2004 and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High-priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of.at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 28 .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and Rrior tooperation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina-licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast-Track Permitting of Pump Station and Force Main adopted June 1,2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings", and one copy of the supporting design calculations to the Non-Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast-Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. - 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall report by telephone to the Raleigh Regional Office, telephone number (919) 571-4700, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or 2 b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Permit issued this the third day of February, 2003 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. KliCne .E., Director Division of Water puality By Authority of the Environmental Management Commission Permit Number W00022241 3 Permit No. W00022241 February 3, 2003 ENGINEER'S CERTIFICATION Partial Final as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time)the construction of the project, , .for the Project Name Location and County Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: The above Engineer's Certification shall be completed and submitted to the address below with one copy of the "Construction Record Drawings"of the wastewater collection system extension as well as supporting design calculations for any pump stations permitted as part of this project. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. NORTH CAROLINA DIVISION OF WATER QUALITY WATER QUALITY SECTION NON-DISCHARGE PERMITTING UNIT 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 0 4 CCDETIR North Carolina Department of Environment and Natural Resources Pat McCrory Donald R. van der Vaart Governor Secretary June 15,2015 Mr. Thomas S. Warren,Jr.,Assistant Town Manager City of Roxboro PO Box 128 Roxboro, NC 27573 Subject: Permit No. WQCS00048 City of Roxboro City of Roxboro Collection System Person County Dear Mr.Warren: In accordance with your application received May 4, 2015, we are forwarding herewith Permit No. WQCS00048,dated June 15, 2D15,to the City of Roxboro for the operation and maintenance of the subject wastewater collection system. This permit shall be effective from November 1, 2015 until October 31, 2023 and shall be subject to the conditions and limitations specified herein. It is your responsibility to thoroughly review this permit. Please pay particular attention to the monitoring and reporting requirements in this permit and any special conditions. Changes have been made to the boiler plate language of the permit. Most of the changes are for clarification purposes, however Condition 1(3) has been removed. The Department of Environment and Natural Resources (DENR) believes that condition was included erroneously in previous permits. It was included based on proposed rulemaking by EPA which was never promulgated and in the continued absence of Federal regulations, DENR lacks authority to include such language in a permit. DENR will continue to exercise enforcement discretion when evaluating sanitary sewer overflows that may be considered to be beyond the reasonable control of the Permittee. A highlighted copy of the permit identifying the changes made is available at: http://portal.ncdenr.org/web/wci/swp/ps/cs/apps For purposes of permitting, the collection system is considered to be any existing or newly installed system extension up to the wastewater treatment facility property or point of connection with a separately owned sewer system. The collection system is considered all gravity lines, pump stations, force mains, low pressure sewer systems, STEP systems, vacuum systems, etc. and associated piping, valves and appurtenances that help to collect, manage and transport wastewater to a wastewater treatment plant under the Permittee's ownership or maintained and operated by the Permittee through a perpetual legal agreement. Satellite systems are systems tributary to the Permittee's collection system but those collection systems are not owned or maintained by the Permittee. The system description provided on Page 1 of this permit is meant to provide a general idea about the size of the system and may not be all inclusive of the collection system at the time of permit issuance or afterward. 1617 Ma'Service Center,Raleigh,North Carolina 27699-1617 Phone:919-807-63001 Internet:www.ncwaterquality.org An Eq ia]opportunity IAffirmative Action Employer—Made in part by recycled paper City of Roxboro Collection System June 15,2015 A discharge of wastewater to the environment from the Permittee's wastewater collection system prior to reaching the wastewater treatment facilities is referred to herein as a Sanitary Sewer Overflow (SSO). The evaluation of enforcement options after an SSO will be determined considering all relevant information available or requested of the Permittee, Compliance with all conditions of the permit as well as all statutes and regulations pertaining to the wastewater collection system must be maintained or appropriate enforcement actions may be taken as noted in Condition VI(2). A reportable SSO is an SSO greater than 1,000 gallons to the ground or an SSO of any amount that reaches surface water (including through ditches, storm drains, etc.). Reporting requirements including the required verbal report and written report to the appropriate regional office are referenced in Condition IV(2). Form CS-SSO can be downloaded from the SSO Reporting area at: http://porta 1,ncdenr.orp/web/wq/swp/ps/cs/sso A notice of deficiency (NOD), notice of violation (NOV), civil penalty, and/or a moratorium on the addition of waste to the system may be issued if adequate justification for an SSO is NOT submitted to the regional office. In order to submit a claim for justification of an SSO, you must use Part II of form CS-SSO with additional documentation as necessary. DWR staff will review the justification claim and determine if enforcement action is appropriate. Please be advised that the information needed to justify a spill is very comprehensive. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty days following the receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh,NC 27699-6714. Unless such demands are made,this permit shall be final and binding. If you have questions regarding compliance,contact the appropriate regional office. If you need additional information concerning this permit, please contact Steve Lewis at(919)807-6308. Sincerely, -L- ./. forS.Jay Zimmerman, Director Division of Water Resources, NCDENR by Deborah Gore, Supervisor Pretreatment, Emergency Response,Collection System Unit(PERCS) enclosure: Permit No.WQCS00048 cc: Raleigh Regional Office,Water Quality Regional Operations Water Resources Central Files—WQCS00048 Steve Reid,NC Operators Certification Program (electronic) PERCS Files(electronic) a A�h CCDEENR STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES SYSTEM-WIDE COLLECTION SYSTEM PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended,and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Roxboro WQCS00048 FOR THE operation and maintenance of a wastewater collection system consisting of, at the time of permit issuance, approximately 81 miles of gravity sewer, approximately 5.4 miles of force main, 11 duplex pump stations, and all associated piping, valves, and appurtenances required to make a complete and operational wastewater collection system to serve the City of Roxboro and any deemed permitted satellite communities pursuant to the application received May 4, 2015, and in conformity with the documents referenced therein and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from November 1, 2015 until October 31, 2023, and shall be subject to the following specified conditions and limitations: Page 3 of 9 I. PERFORMANCE STANDARDS 1. The sewage and wastewater collected by this system shall be treated in the City of Roxboro Wastewater Treatment Facility identified in the permit application and documented in the Division's database. [15A NCAC 02T.0108 (b)] 2. The wastewater collection system shall be effectively managed, maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. In the event that the wastewater collection system fails to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate actions as per the Response Action Plan (Condition 11(9)), as well as any actions that may be required by the Division of Water Resources (Division), such as the construction of additional or replacement sewer lines and/or equipment. [15A NCAC 02T.0108(b)] 3. The Permittee shall establish by ordinance, inter-local agreement or contract its legal authority to require new sewers be properly constructed; to ensure proper inspection and testing of sewer mains and service laterals; to address flows from satellite systems and to take enforcement action as required by Condition 1(4). [G.S. 143-215,913; G.S. 143-215.1(f)(1)] 4. The Permittee shall develop and implement an educational fats, oils and grease program that shall include at least semiannual distribution of educational material targeted at both residential and non- residential users. The Permittee shall also develop and implement an enforceable fats, oils and grease program for non-residential users under which the Permittee can take enforcement against users who have not properly installed, operated and maintained grease traps or grease interceptors as directed or otherwise violated the terms of the enforcement program pertaining to fats,oils and grease. [15A NCAC 02T.0108 (b)] 5. The Permittee shall adopt and implement a Capital Improvement Plan (CIP) to designate funding for reinvestment into the wastewater collection system infrastructure.The CIP should address the short- term needs and long-term "master plan" concepts. The CIP should typically cover a three to five year period and include a goal statement, description of the project area, description of the existing facilities, known deficiencies (over a reasonable period) and forecasted future needs. Cost analysis is integral to the CIP. [G.S. 143-215.96] 6. Overflow piping from manholes and pump stations, excluding piping to approved equalization structures, known or discovered after permit issuance shall be immediately removed or permanently capped. Plugged or valved emergency pumping connections are allowable for portable pumping or rerouting without intentionally bypassing the wastewater treatment facility. [15A NCAC 02T.0108(b)] 7. The Permittee shall maintain a contingency plan for pump failure at each pump station. If one of the pumps in a pump station containing multiple pumps fails, the process of repairing or replacing the pump shall be initiated immediately and the new parts or pump shall be installed as soon as possible. The permittee shall provide justification for delay in initiating the process for repair or replacement at the Division's request. If the pump in a simplex pump station serving more than a single building or pump stations not capable of pumping at a rate of 2.5 times the average daily flow rate with the largest pump out of service fails, it shall be replaced immediately. [15A NCAC 02T.0305(h)(1)] 0 Page 4 of 9 8. Each pump station shall be clearly and conspicuously posted with a pump station identifier and an emergency contact telephone number at which an individual who can initiate or perform emergency service for the wastewater collection system 24 hours per day, seven days per week can be contacted. This emergency contact telephone number shall be coupled with instructions that the emergency contact should be called if the visual alarm illuminates, if the audible alarm sounds, or if an emergency is apparent. [15A NCAC 02T,0305 (h) (2)] 9. Pump station sites, equipment and components shall have restricted access. 115A NCAC 02T.0305 (h) (4)] 10. Pump stations that do not employ an automatic polling feature (i.e. routine contact with pump stations from a central location to check operational status of the communication system) shall have both audible and visual high water alarms. The alarms shall be weather-proof and placed in a clear and conspicuous location. Permits issued for the construction of pump stations that included high water alarms in the description must maintain the alarms even if simple telemetry (i.e. notification of an alarm condition initiated by the pump station control feature) is installed. [15A NCAC 02T.0305 (h) (1)] 11. For all newly constructed, modified and rehabilitated pump stations, all equipment and components shall be sealed within a corrosion-resistant coating or encasement to the extent practicable and equivalent to the minimum design criteria unless the permittee can demonstrate it is not practicable or another form of corrosion resistance is employed. [15A NCAC 02T.0108(b)] II. OPERATION AND MAINTENANCE REQUIREMENTS 1. Upon classification of the collection system by the Water Pollution Control System Operators Certification Commission (WPCSOCC), the Permittee shall designate and employ a certified operator to be in responsible charge (ORC) and one or more certified operator(s) to be back-up ORC(s) of the facilities in accordance with 15A NCAC 8G .0201. The ORC shall visit the system within 24 hours of knowledge of a bypass, spill, or overflow of wastewater from the system, unless visited by the Back- Up ORC, and shall comply with all other conditions of 15A NCAC 8G .0204. [15A NCAC 08G .0200 et.seq.] 2. The Permittee shall develop and adhere to a schedule for reviewing all inspection, maintenance, operational and complaint logs. If the review process results in the identification of any recurring problem in the wastewater collection system that cannot be resolved in a short time period, the Permittee shall establish a plan for addressing the problem(s). [15A NCAC 02T.0108(b)] 3. The Permittee shall develop and adhere to a schedule for testing emergency and standby equipment. [15A NCAC 02T.0108(b)] 4. The Permittee shall develop and implement a routine pump station inspection and maintenance program which shall include the following maintenance activities: a. Cleaning and removing debris from the pump station structure, outside perimeter, and wet well; b. Inspecting and exercising all valves; c. Inspecting and lubricating pumps and other mechanical equipment; and d. Verifying the proper operation of the alarms,telemetry system and auxiliary equipment. [15A NCAC 02T ,0108 (b)] Page 5 of 9 S. For each pump station without pump reliability(i.e. simplex pump stations serving more than a single building or pump stations not capable of pumping at a rate of 2.5 times the average daily flow rate with the largest pump out of service), at least one fully operational spare pump capable of pumping peak flow shall be maintained on hand. [15A NCAC 02T .0305(h)(1) (A)] 6, The Permittee shall maintain on hand at least two percent of the number of pumps installed, but no less than two pumps, that discharge to a pressure sewer and serve a single building, unless the Permittee has the ability to purchase and install a replacement pump within 24 hours of first knowledge of the simplex pump failure or within the storage capacity provided in a sewer line extension permit. [15A NCAC 02T.0108(b)] 7. Rights-of-way and/or easements shall be properly maintained to allow accessibility to the wastewater collection system unless the Permittee can demonstrate the ability to gain temporary access in an emergency situation where existing land-use conditions do not allow the establishment and maintenance of permanent access. In this case, the Permittee shall continue to observe the lines visually, utilize remote inspection methods (e.g. CCTV) and use the opportunity of drier conditions to perform further inspections and necessary maintenance. [15A NCAC 02T.0108(b)] 8. The Permittee shall assess cleaning needs, and develop and implement a program for appropriately cleaning, whether by hydraulic or mechanical methods, the wastewater collection system. At least 10 percent of the gravity wastewater collection system, selected at the discretion of the ORC, shall be cleaned each year. Preventative cleaning is not required for sewer lines less than five years old unless inspection otherwise reveals the need for cleaning or cleaning is required by a sewer line extension permit. (15A NCAC 02T.0108 (b)] 9. The Permittee shall maintain a Response Action Plan that addresses the following minimum items: a. Contact phone numbers for 24-hour response, including weekends and holidays; b. Response time; c. Equipment list and spare parts inventory; d. Access to cleaning equipment; e. Access to construction crews, contractors and/or engineers; f. Source(s)of emergency funds; g. Site restoration and clean up materials; and h. Post-SSO assessment. (15A NCAC 02T.0108 (b)] 10. The Permittee, or their authorized representative, shall conduct an on-site evaluation for all SSOs as soon as possible, but if feasible no more than two hours after first knowledge of the SSO. The Permittee shall document in its 5-day report why it was unable to initially respond to any SSO location within two hours. [15A NCAC 02T.0108(b)] 11. In the event of an SSO or blockage within the wastewater collection system, the Permittee shall restore the system operation, remove visible solids and paper, restore any ground area and restore the surroundings. [15A NCAC 02T.0108 (b)] M. RECORDS 1. Records shall be maintained to document compliance with Conditions 1(4), 11(2)-II(4), II(7)-II(8), IV(3) and V(1) -V(4). Records shall be kept on file for a minimum of three years. [15A NCAC 02T.0108(b)] O Page 6 of 9 2. The Permittee shall maintain adequate records pertaining to SSOs, and SSO or wastewater collection system complaints for a minimum of three years. These records shall include, but are not limited to, the following information: a. Date of SSO or complaint; b. Volume of wastewater released as a result of the SSO and/or nature of complaint; C. Location of the SSO and/or complaint; d. Estimated duration of the SSO; e. Individual from the Division who was informed about the SSO and/or complaint, when applicable; f. Final destination of the SSO; g. Corrective actions; h. Known environmental/human health impacts resulting from the SSO; and i. How the SSO was discovered. [15A NCAC 02T.0108(b)] 3. The Permittee shall maintain an up-to-date, accurate, comprehensive map of its wastewater collection system that also notes the locations where other wastewater collection systems become tributary. If a comprehensive map of the collection system has not been established, a rough sketch shall be drawn. The Permittee shall map approximately 10 percent of its existing collection system each year for the next ten years beginning at the original permit issuance date, or until complete, whichever is sooner. The comprehensive map shall include, but is not limited to: pipe size, pipe material, pipe location, flow direction, approximate pipe age, and each pump station identification, location and capacity. [15A NCAC 02T.0108(b)] 4. The Permittee shall maintain records of all of the modifications and extensions to the collection system permitted herein. The Permittee shall maintain a copy of the construction record drawings and specifications for modifications/extensions to the wastewater collection system for the life of the modification/extension. Information concerning the extension shall be incorporated into the map of the wastewater collection system within one year of the completion of construction. The system description contained within this permit shall be updated to include this modification/extension information upon permit renewal. [15A NCAC 02T.0108 (b)) IV. MONITORING AND REPORTING REQUIREMENTS 1. In the event of an SSO the Division may require monitoring that is necessary to ensure surface water and groundwater protection and an acceptable sampling and reporting schedule shall be implemented. [15A NCAC 02T.0108 (c)] 2. The Permittee shall verbally report to a Division of Water Resources staff member at the Raleigh Regional Office,at telephone number (919) 791-4200 as soon as possible, but in no case more than 24 hours following first knowledge of the occurrence of the following circumstances within the collection system which is under the Permittee's ownership or maintained and operated by the Permittee through a perpetual legal agreement: a. Any SSO and/or spillover 1,000 gallons to the ground; or b. Any SSO and/or spill, regardless of volume,that reaches surface water. Voice mail messages or faxed information shall not'be considered as the initial verbal report. SSOs (and other types of spills) occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number(800) 858-0368 or(919)733-3300. Page 7 of 9 Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five business days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. [G.S. 143-215.1C(a1)] 3, The Permittee shall meet the annual reporting and notification requirements provided in North Carolina General Statute§143-215.1C. V. INSPECTIONS 1. The Permittee or the Permittee's designee shall inspect the wastewater collection system regularly to reduce the risk of malfunctions and deterioration, operator errors, and other issues that may cause or lead to the release of wastes to the environment, threaten human health or create nuisance conditions. The Permittee shall keep an inspection log or summary including,at a minimum,the date and time of inspection, observations made, and any maintenance, repairs, or corrective actions taken by the Permittee. [15A NCAC 02T.0108 (b)] 2. Pump Stations that are not connected to a telemetry system (i.e., remote alarm system) shall be inspected by the permittee or its representative every day (i.e., 365 days per year). Pump stations that are connected to telemetry shall be inspected al least once per week. [15A NCAC 02T.0108(b)] 3. A general observation by the permittee or its representative of the entire wastewater collection system shall be conducted at least once per year. [15A NCAC 02T.0108(b)] 4. Inspections of all high priority lines (i.e. aerial line, sub-waterway crossing, line contacting surface waters, siphon, line positioned parallel to stream banks that are subject to eroding in such a manner that may threaten the sewer line, or line designated as high-priority in a permit)shall be performed at least once per every six-month period of time. A list of high-priority lines is presented as Attachment A and is hereby incorporated into this permit condition. New high priority lines installed or identified after permit issuance are incorporated by reference and subject to this permit condition until permit renewal where they shall be referenced in writing in Attachment A. [15A NCAC 02T.0108(b)] VI. GENERAL CONDITIONS 1. This permit is not transferable. In the event that the Permittee desires to transfer ownership of the wastewater collection system or there is a name change of the Permittee, a formal permit modification request shall be submitted to the Division. The request shall be accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. Such request will be considered on its merits and may or may not be approved. [15A NCAC 02T.0104; G.S. 143-215.1(d)(3)] 2, Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute §143- 215.6A through§143-215.6C,and a sewer moratorium may be established. [15A NCAC 02T.0104] 3. The issuance of this permit does not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies(i.e., local,state, and federal) having jurisdiction. [G.S. 143-215.1(b)] 4. The issuance of this permit does not prohibit the Division from reopening and modifying the permit, O revoking and reissuing the permit or terminating the permit as allowed by the laws, rules, and regulations or as needed to address changes in federal regulations with respect to the wastewater collection system, in accordance with required procedures. [G.S. 143-215.1(b)(4)] Page 8 of 9 5. The Permittee shall pay the annual fee within thirty (30) days after being billed by the Division. Failure to pay the fee accordingly may cause the Division to initiate action to revoke this permit. [15A NCAC 02T.0110(4)] 6. The Permittee shall file an application for renewal of this permit at least six months prior to the expiration of this permit. Upon receipt of the request, the Director will review the adequacy of the wastewater collection system described therein, and if warranted, will extend the permit for a period of time and under such conditions and limitations, as the Director may deem appropriate. [15A NCAC 02T.0109) 7. The Permittee shall notify the Division's Pretreatment, Emergency Response and Collection Systems Unit in writing at 1617 Mail Service Center, Raleigh, North Carolina 27699 of any changes to the name and/or address of the responsible party (i.e. mayor, city/town manager) of the wastewater collection system. [15A NCAC 02T.0106 (c)] 8. Any duly authorized officer, employee, or representative of the Division may, upon presentation of credentials, enter and inspect any property, premises or place on or related to the collection system at any reasonable time for the purpose of determining compliance with this permit, may inspect or copy any records that must be maintained under the terms and conditions of this permit, and may obtain samples of wastewater, groundwater, surface water, soil, or plant tissue. [15A NCAC 02T.0110(3)] 9. The Permittee or their authorized representative shall have available a copy of this permit to present upon request by any duly authorized officer, employee, or representative of the Division. [15A NCAC 02T.0104] Permit issued this the 15th of June, 2015 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for S.Jay Zimmerman, Director Division of Water Resources By Authority of the Environmental Management Commission by Deborah Gore, Pretreatment, Emergency Response, Collection System Unit Supervisor Division of Water Resources, NCDENR Page 9 of 9 "Attachment A for Condition V (4)" All are aerial creek crossings 1) Broad St. & Burch Ave. 2) Bywood Drive 3) C&A Warehouse off 49 North 4) China Buffet 813 N. Madison 5) Charles Circle 2 crossings 6) Chublake St. & W. Gordon St. 7) 2 crossings on main line of Piedmont Community College 8) 2 crossings on main line at end of Chestnut St. 9) N.C. License Plate Agency 811 N. Madison Blvd. 10) 2 crossings at bridge on Depot St. 11) Family Dollar 739 N. Madison Blvd. 12) Gentry's Fine Jewelry 817 N. Madison Blvd. 13) End of Garret St. 14) McDonald's 737 N. Madison Blvd. 15) N. Park Drive & US 501 North 16) Roxboro Trading Post 101 Virgilina Rd. 17) Roses 1029 N. Madison Blvd. 18) Planters Warehouse 1230 N. Main St. 19) Wachovia Bank 515 N. Madison Blvd. 20) Walker St. at culvert 21) Reams Ave. & Chublake St. 22) Crossing at end of Academy St. 23) Old Womack Building on N. Madison 24) Wendy's 735 N. Madison Blvd. 25) Walker's Insurance 801 N. Madison Blvd. 26) 319 Ivey St. 27) 314 Jones St. 28) 312 Jones St. 29) 310 Jones St. 30) 306 Jones St. 31) 418 West Morehead St. 32) 1510 North Main St. 33) 206 North Foushee St. 34) 310 East Morehead St. 3 5) Dolly St. Apartments _I I City of Roxboro Western Sewer Easements 1 Southside Force Main Telics# PARCEL# CLAIMANT PIN# DB/ PG 001 106-22 H. W. Winstead, Jr 0905-13-02-4659 200/776 002 107-11-1 Richard T Duncan, Jr and Bonnie Dunc 0904-06-37-3783 1056/128 003 107-79 HenryO Newell and others 0904-06-38-7512 146/422 004 118-18 Person Count 0905-09-06-1184 905/395 005 122-56 Gordon and Faye Solomon 9996-20-80-9646 804/63 006 122-78 Town &Country Builders 9996-20-80-4681 652/672 007 25-7 CHG-MHP Roxboro, LLC 9996-00-91-2741 944/857 008 25-9 Market lace Properties, LLC. 9996-20-91-8644 80/617 009 26-13 Marketplace Properties, LLC. 0906-17-01-0879 220/422 010 112-35 Thomas Berkeley Carver 9995-16-93-0177.00 942/667 011 116-10-1 Moose Lodge 2005 95/270 Tarrence R. Stewart& Caprice Ni 012 126-3 Drumwri ht 1081/375 013 126-4 Tyler William Shernisky 1011/489 014 112-90 Troy Enterprises, Inc 0905-13-04-8713 208/884 015 127-1-17 Jeff and Paige Fitzgerald 0906-13-04-7278 273/8 016 127-1-18 Jeff and Paige Fitzgerald 0906-13-04-7482 273/8 0171 128-14 Mason Farm Estates, LLC 0906-09-05-6473 1003/77 018 128A-18 James and Brenda Bittner 0906-00-04-7595 1051/525 019 128A-54 James and Brenda Bittner 0906-13-04-9875 882/58 020 26-11 TKTK Associates 0906-17-02-0144 219/584 021 26-12 County of Person, NC 0906-17-02-2006 941/96 022 126-14 Admiral Properties, LLC 0906-13-02-4630 919/397 023 126-15 Seven Up Distributing 0906-13-03-2608 188/688 024 116-12 Wagstaff Associates and Partnership 9996-00-70-5056 186/460 025 106-1 Heather Marie SchmittMatthew David V 0905-00-03-8381 1088/352 026 106A-8 Willie and Wilma Brooks 156114 027 106-19 Willie and Wilma Brooks 0904-06-28-8864 182/818 028 108-9-1OUT Donald and Myra West 0905-17-21-0062 1147/270 029 118-1 L Properties LLC 5651523 030 125-65 Cherie M. Allen 0906-13-02-0675 1034/605 031 128A-20 Jason and Jennifer Rogers 0906-13-04-4592 727/286 032 129-37 Carolyn Greene 198/308 033 133-3 Piedmont Technical College 0907-11-56-7508 132/357 034 133-33 William and Kimberly Carver 0907-14-43-6909 790/215 035 133-35 William Gordon Carver, Jr. et ux 0907-14-44-6129 196/682 036 133-36 Gordon Carver, Jr. and Others 0907-14-44-7335 196/682 037 133-37 Gordon Carver, Jr. and Others 0907-14-44-7571 196/682 038 133-4 County of Person, NC 0907-15-64-3726 979/472 039 133-45 Ira James and Michelle Young 0907-14-43-5431 391/710 040 133-46 Gordon Carver, Jr. and Others 0907-14-43-4588 196/682 041 133-47 Gordon Carver, Jr. and Others 0907-14-43-5756 196/682 042 133-5 Gordon Carver, Jr. and Others 0907-14-43-7016 196/682 043 133-55 Stephen and Carla Garrett 0907-18-42-7418 1091/19 044 134-1 Dansfield, LLC 0907-14-31-6132 541/192 045 134-2 Dansfield, LLC 0906-10-27-6849 541/192 046 134-7 HenryLewisBarbara Smithen 0906-09-17-2085 1120/746 047 134-7A John Oakley Estate 0906-09-16-7788 148/30 048 139-8 Wallace O. Clayton 0907-10-35-1637 261/97 049 141-1 Chip F &Sharon W. Lofton 0907-07-68-9272 1046/21 From: Sweater,Jeff To: Robinson.Jason Subject: City of Roxboro Western Sewer Extension Submission Attachments: imaae001.pna Aerial Crossina.odf Hi Jason, Julia Byrd told us you are handling DWR fast track reviews for Person County projects/the eastern side of INC. We are ready to submit the Roxboro Western Sewer Extension project and wanted to see how you prefer the submission be handled? Can we just email everything to you or provide an FTP link to download the information? Or do we need to print two copies of everything and mail everything in? The project is proposed to reroute up to 1,400 gpm of sewer flow to free up capacity within overloaded portions of the City's Marlowe Creek Interceptor. The proposed project generally includes: • Replacement of the City's Southside pump station • 4.3 mile installation of a new 16" sewer force main. • 3.8 mile installation of new 18" and 24" gravity sewer. Not sure if the project can be fast tracked since we have a mid-water column aerial crossing (see attached). Based on this, would you still be the reviewer? Thanks, Jeff Sweater, PE LaBella Associates I Senior Project Manager 0 704-941-2143 direct 704-376-6423 office 941-374-3930 cell 400 S.Tryon St,Suite 1300 Charlotte, NC 28285 labellanc.com LaBeRa Powered by partnership. 'i ; �'I J •;••��: �((/' / 400 S. Tryon Street, Suite 1300 • ti'' �� Il "� :•L`•' ��' I ; Charlotte, INC 28285 �� qi, 1,, •; i I )� / 704-376-6423 N.C. License # C-0430 ETLAN label) co TOP % ( apc EX SSMN i �• 1 •. .••• • I , r ' BOTTOM OF BOX 478.09' \� /I i •;;�,•;;,•••, ' �l 469,68' �� \ i•I I i 1 I i.,.• y�/ I i I ��I �` ` ! ���(;: ;;•• i // ) S'MH SkRUCTURE�IQ_ _ F T / I^ 1 �, / I i 2+89 -i SON „� 1 \' Ex wooDs , 11 ; ;:• I ; `RIM=475.02 'a I % _____� ') � i •f;;,I ,�i � � i N�INV=467,78�, EX WOODS - I/ a ,.•' , A `� I W NJV�46ZS8 I a "'�100YRFLOOD- f1 �I :� ' �`.�`�\ --�_' o` �\�\P `OC`G K. 27° -_- - 5 F 0"A' R�� P ASSOC/qI \� 1 �,• P g551" _ _ �\ `'� z289.t• 1 , '. A��� IMITS OF DISTURBANCE SEAL CERT.52904. CHIP F. LOFTON AND WIFE,�dA 056476 szsa A �1 7rV DB 1046 PG 21 PB 13 PC 12 °!.,�� .•`°���� '9acorre.N . EX.SS MH 0 1 TEMPORAR�STONE - -- cy (� WE ��___ L .......„8/4/231 TOP=478.88• �x � �1 „� OUTLET(TY ,, INV=470.21.8"(NE 1 \ SEE DETAIIgO2 \ 'a \By. ------ INV=467.00• 30"(SE) 4 `� MARLOWE$1 � � I TEMPORARY SEDIMENT � '00 O 1 \\��, C ��--TENCE(TYP.)SEE BET.2/U401 888°54'oa.9rw ,\ PROP.INV=467,50' 24"(SW) CREEK CROSSIN ( \ �) xs44.6a ` '$" i S 02023 LaBelle Associates 8F�DlP (AERIAL) >� \ 48 EX SS 100 YR FLOOD 00 118° TOP 480 86" INV—470.7;8••(NE) - INV= 470.76'8"(SW) APPROXIMATE LOCATION OF EXIST.SEWER TEMP STRUCTION �RANCE.SEED 402 gLG SA MH STRUCTURE- - EX MOBILE \ 1 �1 / \ ' Q 1 / \ TDIAMH HOME NFS -� ` i— 1 STA.6+34 - 7 itOXBO )F <�F I_-RIM=474s6 \ i/ / NO%TB CAROlL�9 0 R O D / E INV=68.11 / ��- Q pS6,gCT OG/y NO `���`` ��\\` / ��I � \ SW INV=4&41/ / Y 2S6 \ Ilk CITY OF ROXBORO WESTERN SEWER SYSTEM - GRAVITY SEWER, FORCE 490 490 MAIN & SOUTHSIDE PUMP STATION X.6 DA.SS H + I IV-46 00" 0°SE) o 11 V=467.0'2"(S N0: DATE: DESCRIPTION: PENSIONS PROJECT NUMBER: 480 „< 480 2201369 ,I _ DRAWN BY: EP/JUR REVIEWED BY: gRH ISSUED FOR: PERMITTING RE A14 EXI T.M%NHU LE 101 R F 00 P N E STI G GI iOU D 3 — DATE: 08/04/2023 IST.MAN HOLE — DRAWING NAME. 470 470 - PROPOSED GRAVITY E SEWER LINE ±4.16' 4"C 00 I 0.1 RE K C OSSI G. BO 0 OF RE K E 3 EM ED M INTAN STI CO TO RS EE ET. 43 _ STA. 0+00 TO 7+00 E ±48 24"ON SPA DI @ .10BEE UL -- -- m 3 P 0 IL 40' DRAWING NUMBER'. o 46) E -4 460 -0+75 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 U 101 �ry From: Sweater,Jeff To: Wild,Elaine Cc: Pasha,Tanvir Subject: RE: [External]FW: Permits for The Roxboro Western Sewer Extension Project(PERSO-2024-003) Date: Friday,February 9,2024 11:16:18 AM Attachments: imaae001.Dno image002.png imaae003.Dna image004.p_ng imaae005.Dna image006.png DWR 2-8-2024.Ddf CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Thanks, Elaine. The City is at the post office as we speak sending the attached via priority mail. It should be to DEQ Regional Office by Monday afternoon. Have a great weekend! Thanks, Jeff Sweater, PE La Bella Associates I Senior Project Manager 0 704-941-2143 direct 704-376-6423 office 941-374-3930 cell 400 S.Tryon St,Suite 1300 Charlotte, NC 28285 labellapc.com From: Wild, Elaine <elaine.wild@deq.nc.gov> Sent: Friday, February 9, 2024 7:44 AM To: Sweater, Jeff<jsweater@La Bella PC.com> Subject: RE: [External] FW: Permits for The Roxboro Western Sewer Extension Project (PERSO-2024- 003) Hi Jeff, See my responses in blue. Thanks, Elaine Wild Environmental Engineer Division of Water Resources—NPDES Industrial Permitting Unit North Carolina Department of Environmental Quality elaine.wildCd)deq.nc.gov Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Sweater,Jeff<isweaterCcDLaBelIaPC.com> Sent:Thursday, February 8, 2024 4:17 PM To: Wild, Elaine<elaine.wild(@deq.nc.gov> Subject: RE: [External] FW: Permits for The Roxboro Western Sewer Extension Project (PERSO-2024- 003) CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Hi Elaine, Two quick questions: 1. Do you know if DEQ would have an issue with using Adobe's built-in digital signature platform: https://helpx.adobe.com/acrobat/using/validating-digital-signatures.html Yes, that is fine to use. 2. If push comes to shove for the City, what address should they use to send the wet signed FTSE? Your old Regional office address (see below), or do you have a Central office address you want it sent to? If you are not able to get the digital signature to work, then please mail the wet ink page to the Regional Office, address below is great, but I did edit it a little. It will be placed with the original application. Attn: Elaine Wild &Tanvir Pasha Raleigh Regional Office Division of Water Resources 3800 Barrett Drive Raleigh, North Carolina 27609 (919) 791-4200 Thanks, Jeff Sweater, PE LaBella Associates I Senior Project Manager 704-941-2143 direct 704-376-6423 office 941-374-3930 cell 400 S.Tryon St,Suite 1300 Charlotte, NC 28285 labellaac.com From: Sweater,Jeff<isweater(@LaBellaPC.com> Sent: Wednesday, February 7, 2024 9:57 PM To: Wild, Elaine <elaine.wild(@deg.nc.gov> Subject: RE: [External] FW: Permits for The Roxboro Western Sewer Extension Project (PERSO-2024- 003) Very much appreciated Elaine! I think I have it all straight in my head now. Just for my own edification, is there any way I can find the permit number for sewer infrastructure if our client/utilities don't have it? The following is what I'm sending to the City to sign and turn it back around quickly. Thanks, Jeff Sweater, PE La Bella Associates I Senior Project Manager L 704-941-2143 direct 704-376-6423 office 941-374-3930 cell 400 S.Tryon St,Suite 1300 Charlotte, NC 28285 labellarmcom From: Wild, Elaine <elaine.wild(@deq.nc.gov> Sent: Wednesday, February 7, 2024 8:20 AM To: Sweater, Jeff<isweater(@La BellaPC.com> Subject: RE: [External] FW: Permits for The Roxboro Western Sewer Extension Project (PERSO-2024- 003) Good Morning Jeff, Please see my responses to your questions in blue. Also, in Section II the permit number for the Southside Pump Station should be WQ0022241 since modifications to the pump station occur in this permit, not in the collection system permit WQCS00048. The Downstream Facility Name (Sewer) is the name of the downstream sewer line that the Western Sewer project will tie into so since the project connects to the collection system,then the Facility Name should be "City of Roxboro Collection System"and the permit number is WQCS00048. Thanks, Elaine Wild Environmental Engineer Division of Water Resources—NPDES Industrial Permitting Unit North Carolina Department of Environmental Quality elaine.wild(adeq.nc.gov Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Sweater,Jeff<jsweater(@La BellaPC.com> Sent:Tuesday, February 6, 2024 6:12 PM To: Wild, Elaine<elaine.wildC@deq.nc.gov> Subject: RE: [External] FW: Permits for The Roxboro Western Sewer Extension Project (PERSO-2024- 003) CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Hi Elaine, Attached is the revised FTA page 2 awhile. Attached is also a copy of the latest signed FTSE that was submitted and delivered on Nov. 14th to DEQ, which does include zero new flow to the station in section I.f. The only change I made was using the current station's existing pumping rate of 1,054 gpm x 60 min x 24 hr= 1.517 MGD (based on a pump test done during the beginning of 2021). Please submit a recently signed FTSE form. The Division will accept verified electronic signatures (DocuSign or something similar) and it can be emailed, it does not need to be mailed in. With the FTSE I'm a bit more confused. I might need a quick call to get me on track. The intent of this project is to permit the upgraded South Side PS to match the new station's firm capacity, at 1,400 gpm based on the approved PER. But our PER is confusing in my opinion, especially when it comes to the flow analysis section. Here is a breakdown of the flows discussed within and the original permit you provided me: Ex. Southside PS Permitted Flow from (per WQ0022241): 950 gpm (1.3680 mgd) Nov. 2019 Marlowe Creek Outfall Sewer Study— Design Flowrate: 1,140 gpm (1.6416 mgd) Jan. 2021 La Bella performed Southside PS Test Min Flowrate*: 1,054 gpm (1.5178 mgd) Jan. 2021 La Bella performed Southside PS Test Max Flowrate*: 1,199 gpm (1.7266 mgd) 2024 FTA design flow rate (currently being reviewed): 1,400 gpm (2.0160 mgd) *The current Southside PS was tested and found to operate at the following flow rates. The minimum flow rate observed at the Southside occurred when competing against the Ducan PS flowrate. These two stations currently share a portion of a common force main and impact each other's pumping rate when both are in operation. Southside Southside PS Capacity with....Duncan Pumps Running Pumps Running Zero One Two One 1.199 gpm 1.054 (not modeled) Two 1,543 {not modeled! 1,321 Do I need to update the FTSE based on the following (based on the current station's permitted capacity is at 950 gpm) I believe you told me to use the existing pump station capacity for the FTSE. We only had 1,054 gpm (1.517 mgd) as the existing station capacity based on our pump test. The City didn't have a copy of the WQ0022241 permit in their records (you sent that to me). So sounds like I need to do the following?When filling out the pumping capacity and design flow of the pumps in Section II of the FTSE, you could leave the 1.517 MGD and 0.607 MGD listed as the Firm Capacity and the Design Average Daily Flow since you provided a note indicating that these are current pumping rates based on pump tests. OR you could indicate the permitted pumping capacities shown below. I think that both methods are valid since there are no pump runtime meters for the Southside PS. List pump stations located between the project connection point and the W WTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Average Obligated, Pump Pump Daily Approx. Not Yet Total Current Station Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Permit Capacity,• (Firm/pt), Daily Flow, Daily Flow, Obligated Available Number) No. MGD MGD MGD MGD Flow Capacity*** Southside WQCS00048 t.5�46L1.. 0-60� 0.300MGD1 0.012MGD 0.312MGD 0-�]I 1.368 MGD 0.5472 MGD 0.2352 MGD I assume once the new pump station is constructed, the Engineers construction cert is submitted, and the operation permit has been issued by DEQfor the upgraded station, the City should use 1,400 gpm (2.016 mgd) as the permitted Southside station capacity for future FTSEs they process? Haven't gone through the entire process yet in NC. I can be a bit thick about things when I don't understand the entire process. I just don't want to permit an upgrade PS and our client ends up with no additional capacity once it is constructed and operational. Yes, once the project is completed and certified, the City will begin using 1,400 GPM as the permitted pumping capacity for the PS. Thanks, Jeff Sweater, PE La Bella Associates I Senior Project Manager 0 J 704-941-2143 direct 704-376-6423 office 941-374-3930 cell 400 S.Tryon St,Suite 1300 Charlotte, NC 28285 labellanc.com From: Wild, Elaine<elaine.wildC@deq.nc.g_ov> Sent:Tuesday, February 6, 2024 1:12 PM To: Sweater,Jeff<isweaterPLaBeIIaPC.com> Subject: RE: [External] FW: Permits for The Roxboro Western Sewer Extension Project (PERSO-2024- 003) Hi Jeff, Please see my comments in blue. Also, Page 2, Sections V1.4-6 can be left blank since this is a zero flow permit. When resubmitting,just send back page 2, 1 don't need the entire application again. The FTSE showing zero flow being requested, needs to be signed by Roxboro WWTP, it can be a digital signature (verified like DocuSign or similar). Thanks, Elaine Wild Environmental Engineer Division of Water Resources—NPDES Industrial Permitting Unit North Carolina Department of Environmental Quality elaine.wildl@deq.nc.gov Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Sweater,Jeff<jsweaterPLaBeIIaPC.com> Sent:Tuesday, February 6, 2024 11:19 AM To: Wild, Elaine<elaine.wild(@deq.nc.gov> Subject: [External] FW: Permits for The Roxboro Western Sewer Extension Project (PERSO-2024-003) CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Elaine, I have attached here the latest FTA and FTSE applications the City of Roxboro sent to DEQ with their wet signature to your attention. USPS shows they were delivered at 2:47 pm on 11/14/23. Can you look at the attached "FTA 10-23 Updated 11-10-23.pdf' and see if this is how you wanted it to look based on your email comments from 10/19/23 at 10:41 am? Or do I still need to remove all wording from Section 7? 1 deleted the narrative that was attached to this application to avoid any confusion in the future since that was updated and sent via email on 12/15/23 to address the minimum design criteria for aerial crossings. No new narrative needed. I do have a question about Page 2, Section 5; which should be right up your alley to answer: What is your advice on how to address this? Leave both unchecked as it is, check one of the boxes, or move the 20%to the commercial category. See my response in the email. Background Info if needed: I was told by the City the anticipated waste load will be an 80/20 split between residential and industrial uses/flows. I currently have nothing checked for "If Industrial, is there a Pretreatment Plan in effect?". I'm not sure if Roxboro does have a plan in place or not, but I would think they should based on the size of their system.Since this is a zero flow permit, no wastewater type designation needed at this time. A permit modification may need to be submitted prior to any wastewater generated by this project to be able to flow to the receiving WWTP. However, my understanding is that these industrial uses are more so referring to the type of zoning for the land and not the actual strength of wastewater generated. The waste I believe will be large commercial businesses (warehouses, light manufacturing not needing process water), which are considered domestic strength wastewater. I didn't check one of the boxes since I've never heard of anyone using or defining "commercial strength wastewater "and assumed it had to refer to zoning uses. I'm used to most states having detailed instructions and definitions of terms on how these forms are to be filled out (which I'd think a state like Michigan would have and you know what I'm talking about). Or the state will make the staff's internal SOP for reviewing the permits on their website for public use. I've found this prevents reviewers from having to answer a tone of simple questions that could easily be addressed within a detailed set of instructions and helps a lot with training new agency staff members. Only bring this up since you were talking about helping update NC DEC's processes. Let me know if the engineering community providing comments on this helps push through many of these initiatives, which may not occur if only brought up by staff as needing to be done/updated? The Division is constantly working on ways to improve all processes and welcomes feedback and suggestions. I emailed these documents rather than calling so you can see the document, but please give me a call on my cell if easier/quicker for you (this is my office phone as well as my cell phone). Thanks, Jeff Sweater, PE La Bella Associates I Senior Project Manager 0:3 704-941-2143 direct 704-376-6423 office 941-374-3930 cell 400 S.Tryon St,Suite 1300 Charlotte, NC 28285 labellapc-corn From: Sweater,Jeff Sent: Monday, November 27, 2023 9:32 AM To: Wild, Elaine<elaine.wild(@deq.nc.gov>; Allen, Isaac I <isaac.allen(@deq.nc.gov>; Chawla, Sharan <sharan.chawla(@deq.nc.gov>; Fayad, Abdulrahman B<abdulrahman.fayad(@deq.nc.gov>; Wilson, Susan A<susan.wilson(@deq.nc.gov> Cc: Houston, Brian <bhouston(@LaBellaPC.com>; Douglas, Ryan <rddouglas(@La Bella PC.com>; Prunchak, Eric<eprunchak(@La Bella PC.com>; Lockhart,Allen <blockhart(@cit)lofroxboro.com> Subject: Permits for The Roxboro Western Sewer Extension Project (PERSO-2024-003) All, I wanted to verify if DEQ has everything they require for the 401/404 and DWR sewer extension permit technical reviews, and are currently in the process of being generated, if any are required. The only outstanding comments I'm aware of are from the attached email. These were addressed and the original applications were resubmitted on 11/14/2023 as per the delivery notification below (see draft copies of revised applications). I tried to get guidance from Elaine Wild multiple times prior to resubmitting, but she never got back to me. I'm wondering if she is still with DEQ since she was super responsive prior to her comments being emailed on 10/19/23? Please verify that someone at DEQ has received these revised DWR applications and that things are moving forward in the right direction. Tracking Number: E1031379844US (D Copy Add to Informed Delivery G Delivered Scheduled Delivery by Delivered,In/At Mailbox RALEIGH,NC 27609 T U ES D AY November 14,2023,2 pm 14 by 9eeAlTreebnHisto" November 2023 QI 6:00pm O What Do LISPS Tracking Statuses Mean? Your item was delivered in or at the mailbox at 2:47 pm on November 14,2023 in RALEIGH,NC 27609.Waiver of signature was exercised at time of delivery. Get More Out of USPS Tracking: M USPS Tracking Plus Thanks, Jeff Sweater, PE La Bella Associates I Senior Project Manager 0 J 704-941-2143 direct 704-376-6423 office 941-374-3930 cell 400 S.Tryon St,Suite 1300 Charlotte, NC 28285 labellapc.com From: Sweater,Jeff Sent:Thursday, October 19, 2023 3:12 PM To: Fayad, Abdulrahman B<abdulrahman.fayad(@deq.nc.gov>; Wild, Elaine <elaine.wild(@deq.nc.gov>; Lockhart, Allen <blockhart(@cityofroxboro.com> Cc:Allen, Isaac I <isaac.allen(@deq.nc.gov>; Houston, Brian <bhouston(@La Bella PC.com>; Douglas, Ryan <rddouglas(@La Bella PC.com>; Chawla, Sharan <sharan.chawla(@deq.nc.gov>; Prunchak, Eric <earunchak(@LaBeIIaPC.com> Subject: RE: [Ext] 401/404 Permits for The Roxboro Western Sewer Extension Project (PERSO-2024- 003) Good afternoon Abdulrahman, Attached is the Application and Narrative for the wetlands permitting. Please note that the entire package with the wetlands report is 150 MB. If anyone wants the entire submission package, please let me know and I'll set up an FTP site link for download. The size of this document has created some issues thus far. Thanks, Jeff Sweater, PE La Bella Associates I Senior Project Manager 0 ., 704-941-2143 direct 704-376-6423 office 941-374-3930 cell 400 S.Tryon St,Suite 1300 Charlotte, NC 28285 labellapc.com From: Sweater,Jeff<jsweater(c�labellapc.com> Sent:Thursday, October 19, 2023 10:33 AM To: Fayad, Abdulrahman B<abdulrahman.fayad(@deq.nc.gov>; Wild, Elaine <elaine.wildPdeq.nc.gov>; Lockhart, Allen <blockhart(@cit)lofroxboro.com> Cc:Allen, Isaac I <isaac.allen(@deq.nc.gov>; Houston, Brian <bhouston(@La Bella PC.com>; Douglas, Ryan <rddouglas(@La Bella PC.com>; Chawla, Sharan <sharan.chawla(@deg.nc.gov>; Prunchak, Eric <earunchak(@LaBellaPC.com> Subject: RE: [Ext] 401/404 Permits for The Roxboro Western Sewer Extension Project (PERSO-2024- 003) Good morning Abdulrahman, I'll email these applications over today. We are having server issues this morning, so it may not be until this afternoon. But the application number is SAW-2023-01579 for the 401 permit. Do you want the full submission package for each, or just a copy of the signed and submitted Application only for each? Let me know if you need paper copies. Thanks, Jeff Sweater, PE La Bella Associates I Senior Project Manager u J 704-941-2143 direct 704-376-6423 office 941-374-3930 cell 400 S.Tryon St,Suite 1300 Charlotte, NC 28285 labellapc.com From: Fayad, Abdulrahman B<abdulrahman.fayad(@deq.nc.gov> Sent: Wednesday, October 18, 2023 3:29 PM To: Wild, Elaine <elaine.wildC@deq.nc.gov>; Lockhart, Allen <blockhart(@cityofroxboro.com> Cc: Sweater, Jeff<jsweaterPlabellapc.com>; Allen, Isaac I <isaac.allen(cDdeq.nc.gov>; Houston, Brian <bhouston(@LaBellaPC.com>; Douglas, Ryan <rddouglas(@La Bella PC.com>; Chawla, Sharan <sharan.chawla(@deq.nc.gov> Subject: [Ext] 401/404 Permits for The Roxboro Western Sewer Extension Project (PERSO-2024-003) Hello Allen, I'm requesting a copy of the 404 and a copy of the 401 applications. If you have submitted a 401 application from the Division of Water Resources, you should have been provided with a permit number or project ID. Thank you, Abdulrahman Fayad ARPA Engineer II- RRO Division of Energy, Mineral, and Land Resources Department of Environmental Quality 919-791-4210 (office) 919-571-4718 (fax) Abdulrahman.Fayad(cDncdenr.gov Physical Address: 3800 Barrett Drive Raleigh, NC 27609 Mailing Address: 1628 Mail Service Center Raleigh, NC 27699-1612 D E •.[)eputmmt of EmnronmM�Ul Oual�ry Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties by an authorized state official. CAUTION: This email originated from outside the LaBella organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. From: Sweater,Jeff To: Wild,Elaine; Prunchak,Eric Cc: Thomas,Zachary T Subject: RE: [Ext] RE: [External]Western Sewer Project ID# Date: Friday,December 15,2023 2:19:11 PM Attachments: imaae001.Dna image002.pnng imaae003.Dno 5-Project&Existing Permit Narrative 12-15-23.pdf CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Elaine, With now having the 401 Permit ID: DWR#20231690. Attached is the revised narrative to address the MDCGS concerns, so we can still use the FTA. Please let me know if you have any questions. I hope you both have a great Holiday! Thanks, Jeff Sweater, PE La Bella Associates I Senior Project Manager 0:3 704-941-2143 direct 704-376-6423 office 941-374-3930 cell 400 S.Tryon St,Suite 1300 Charlotte, NC 28285 labellaac.com From: Sweater,Jeff<jsweater@La Bella PC.com> Sent:Thursday, December 14, 2023 11:30 AM To: Wild, Elaine<elaine.wild@deq.nc.gov>; Prunchak, Eric<eprunchak@LaBellaPC.com> Cc:Thomas, Zachary T<zachary.thomas@deq.nc.gov> Subject: RE: [Ext] RE: [External] Western Sewer Project ID# Elaine, Eric is reconfirming the number with USACE. Eric said that is what he was provided to him, and that it didn't work for him either to pay the USACE application fees online. We hope to receive and email you the complete ID by the end of today. I'll also email the updated projection narrative today reviewing how the plans/design comply with the MDCGS for the proposed aerial crossing. Thanks, Jeff Sweater, PE La Bella Associates I Senior Project Manager 0z:I 704-941-2143 direct 704-376-6423 office 941-374-3930 cell 400 S.Tryon St,Suite 1300 Charlotte, NC 28285 labellapc.com From: Wild, Elaine <elaine.wildl@deq.nc.gov> Sent:Thursday, December 14, 2023 8:55 AM To: Prunchak, Eric<earunchak(@La Bella PC.com> Cc: Sweater, Jeff<isweaterl@La BellaPC.com>; Thomas, Zachary T<zachary.thomas(cDdeq.nc.gov> Subject: [Ext] RE: [External] Western Sewer Project ID# Hello Jeff, Will you please verify the ID#?The 401 submission ID is typically 8 digits (2023xxxx), not 7. Thank you, Elaine Wild Environmental Engineer Division of Water Resources- Raleigh Regional Office North Carolina Department of Environmental Quality 919.791.4254 Office elaine.wildC@deq.nc.gov Q E Q�� aw�n.a a tmvom..rr awr\ /— Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Sewer Extension Permitting I NC DEO subchapter t rules. ddff(state.nc.us) From: Prunchak, Eric<eorunchakl@La Bella PC.com> Sent: Wednesday, December 13, 2023 4:35 PM To: Wild, Elaine<elaine.wild(@deq.nc.gov> Cc: Sweater,Jeff<jsweaterl@La Bella PC.com> Subject: [External] Western Sewer Project ID# CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Elaine, Thank you for taking the time to assist us with this process.The project ID# is 2023169, Version 1. 1 am working with Rachel (USACE) to get all of her RAI items addressed, it is currently just pending finalizing mitigation. Please let me know if you need any additional information or if you would like to discuss anything in further detail, I am available the rest of this week and most of next week. Thanks again! Eric Prunchak LaBella Associates I Environmental Manager 0:3 703-975-9718 cell 704-376-6423 office 400 S Tryon St Ste 1300 Charlotte, NC 28285 labellapc.com Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties by an authorized state official. CAUTION: This email originated from outside the LaBella organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. From: Sweater,Jeff To: Myers,Joseph M Cc: Wild,Elaine;Allen,Isaac I;Chawla,Sharan; Fayad,Abdulrahman B;Wilson,Susan A; Houston,Brian Subject: [External]City of Roxboro Western Sewer Extension Project(PERSO-2024-003) Date: Monday,February 5,2024 10:35:28 AM Attachments: image001.pnng image002.pnng imaae003.Dna 5-Project&Existing Permit Narrative 12-15-23.pdf RE External Permits for The Roxboro Western Sewer Extension Proiect(PERSO-2024-003).msa Importance: High CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Good Morning Joe, I am following up on my voice message I just left due to finding out that Elaine Wild no longer works at DEQ. Attached is the most recent submission we provided to DEQ/Elaine Wild and below is some of the more recent email correspondence. The City is getting ready to let this project for Bid. We desperately need an update on the status of this permit review. We don't want the project's bid period pushing into the contractor's busiest time of the year and the community get hit with even higher Bids. We've been going round and round with DEQ since August on this project and permit submission. Based on our experience over the last 6 months, we have serious concerns any momentum we gained with Elaine is going to be lost. Thanks, Jeff Sweater, PE LaBella Associates I Senior Project Manager 0 704-941-2143 direct 704-376-6423 office 941-374-3930 cell 400 S.Tryon St,Suite 1300 Charlotte, NC 28285 labellanc.com From: Sweater,Jeff Sent:Tuesday,January 30, 2024 9:17 AM To: Wild, Elaine<elaine.wild@deq.nc.gov> Cc: Houston, Brian <bhouston@La BellaPC.COm> Subject: City of Roxboro Western Sewer Extension Project (PERSO-2024-003) Happy New Year Elaine! Can you give me an update on the status of this permit review? Are you only waiting for approval of the 401/404 permit and there are no other administrative or technical review comments remaining? For your convenience I've attached the following: 1. Email with the last review comment received from you/DEQ. 2. The revised narrative referenced below that accompanied that email on 12/15/23 at 2:18 PM. Hope all is well on your end. Thanks, Jeff Sweater, PE La Bella Associates I Senior Project Manager 0:3 704-941-2143 direct 704-376-6423 office 941-374-3930 cell 400 S.Tryon St,Suite 1300 Charlotte, NC 28285 labellapc.com From: Sweater,Jeff Sent: Friday, December 15, 2023 2:18 PM To: Wild, Elaine<elaine.wild(@deq.nc.gov>; Prunchak, Eric<eprunchak(@La Bella PC.com> Cc:Thomas, Zachary T<zachary.thomas(@deq.nc.gov> Subject: RE: [Ext] RE: [External] Western Sewer Project ID# Elaine, With now having the 401 Permit ID: DWR#20231690. Attached is the revised narrative to address the MDCGS concerns, so we can still use the FTA. Please let me know if you have any questions. I hope you both have a great Holiday! Thanks, Jeff Sweater, PE La Bella Associates I Senior Project Manager 0:3 704-941-2143 direct 704-376-6423 office 941-374-3930 cell 400 S.Tryon St,Suite 1300 Charlotte, NC 28285 labellapc.com From: Sweater,Jeff<jsweater(@La Bella PC.com> Sent:Thursday, December 14, 2023 11:30 AM To: Wild, Elaine<elaine.wild(@deq.nc.gov>; Prunchak, Eric<eprunchak(@La Bella PC.com> Cc:Thomas, Zachary T<zachary.thomas(Ddeq.nc.gov> Subject: RE: [Ext] RE: [External] Western Sewer Project ID# Elaine, Eric is reconfirming the number with USACE. Eric said that is what he was provided to him, and that it didn't work for him either to pay the USACE application fees online. We hope to receive and email you the complete ID by the end of today. I'll also email the updated projection narrative today reviewing how the plans/design comply with the MDCGS for the proposed aerial crossing. Thanks, Jeff Sweater, PE La Bella Associates I Senior Project Manager 0 704-941-2143 direct 704-376-6423 office 941-374-3930 cell 400 S.Tryon St,Suite 1300 Charlotte, NC 28285 labellapc.com From: Wild, Elaine<elaine.wild(@deq.nc.gov> Sent:Thursday, December 14, 2023 8:55 AM To: Prunchak, Eric<eprunchak(@La Bella PC.com> Cc: Sweater,Jeff<*sweater(@La Bella PC.com>; Thomas, Zachary T<zachary.thomas(@deq.nc.gov> Subject: [Ext] RE: [External] Western Sewer Project ID# Hello Jeff, Will you please verify the ID#?The 401 submission ID is typically 8 digits (2023xxxx), not 7. Thank you, Elaine Wild Environmental Engineer Division of Water Resources - Raleigh Regional Office North Carolina Department of Environmental Quality 919.791.4254 Office elaine.wild(@deq.nc.gov Mgrawn a Fmranwta uwir V Email correspondence to and from this address is subject to the North Carolina Public Records law and may be disclosed to third parties. Sewer Extension Permitting I NC DEO subchapter t rules.pdf(state.nc.us) From: Prunchak, Eric<eprunchakt@La Bella PC.com> Sent: Wednesday, December 13, 2023 4:35 PM To: Wild, Elaine<elaine.wild(@deq.nc.gov> Cc: Sweater,Jeff<jsweaterl@LaBellaPC.com> Subject: [External] Western Sewer Project ID# CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Elaine, Thank you for taking the time to assist us with this process.The project ID# is 2023169, Version 1. 1 am working with Rachel (USACE) to get all of her RAI items addressed, it is currently just pending finalizing mitigation. Please let me know if you need any additional information or if you would like to discuss anything in further detail, I am available the rest of this week and most of next week. Thanks again! Eric Prunchak La Bella Associates I Environmental Manager 0 703-975-9718 cell 704-376-6423 office 400 S Tryon St Ste 1300 Charlotte, NC 28285 labellaac.com Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties by an authorized state official. CAUTION: This email originated from outside the LaBella organization. Do not click links or open attachments unless you recognize the sender and know the content is safe. From: Lentz.Zac To: Wild,Elaine Subject: RE: [External]Permits for The Roxboro Western Sewer Extension Project(PERSO-2024-003) Date: Tuesday,November 28,2023 1:13:34 PM Attachments: imaae001.ona image002.g_ng imaae003.g_ng image004.g_ng image005.ona Happy to help! Zac Lentz,PE NPDES Municipal Permitting Division of Water Resources North Carolina Department of Environmental Quality 919.707.3620 (Office) zac.lentz&ded.nc.gov Please note that staffing levels are presently down and responses to inquiries may be delayed, and I apologize in advance. Many staff have a new email address extension which is "@deq.nc.gov". If you send to the original email address,it will be directed to the correct location. From: Wild, Elaine<elaine.wild@deq.nc.gov> Sent:Tuesday, November 28, 2023 1:01 PM To: Lentz, Zac<zac.lentz@deq.nc.gov> Subject: RE: [External] Permits for The Roxboro Western Sewer Extension Project (PERSO-2024-003) Ok. Thank you for your help with this. I appreciate it. Elaine Wild Environmental Engineer Division of Water Resources- Raleigh Regional Office North Carolina Department of Environmental Quality 919.791.4254 Office elaine.wild(@deq.nc.gov Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Sewer Extension Permitting I NC DEO subchapter t rules.pdf(state.nc.us) From: Lentz, Zac<zac.lentz(@deq.nc.gov> Sent:Tuesday, November 28, 2023 1:00 PM To: Wild, Elaine <elaine.wild(@deq.nc.gov> Subject: RE: [External] Permits for The Roxboro Western Sewer Extension Project (PERSO-2024-003) It looks like the letter is required upon certification, so I believe they can proceed without it. I would request that they explicitly address how they meet each of the criteria in their narrative or spell it out in the add info if they don't include it with the application, but otherwise I do not see a justification to not grant their request for a fast track review. Based on the response from Jeff Sweater, it appears that they believe they can demonstrate that they meet the criteria, which is a sufficient response to proceed with the FTA unless you suspect that they cannot in fact meet the MDC's. Zac Zac Lentz, PE NPDES Municipal Permitting Division of Water Resources North Carolina Department of Environmental Quality 919.707.3620 (Office) zac.lentz&ded.nc.gov Please note that staffing levels are presently down and responses to inquiries may be delayed, and I apologize in advance. Many staff have a new email address extension which is "@deq.nc.gov". If you send to the original email address,it will be directed to the correct location. From: Wild, Elaine <elaine.wild(@deq.nc.gov> Sent:Tuesday, November 28, 2023 12:20 PM To: Lentz, Zac<zac.lentzCcDdeq.nc.gov> Subject: FW: [External] Permits for The Roxboro Western Sewer Extension Project (PERSO-2024-003) Hi Zac, Please see Jeff's response below in regards to the mid-water column aerial crossing referenced in my 11/22 email. Is this sufficient to proceed with FTA or should they provide additional information? Also, should they provide a letter from the City or should I just ask them to put this information in the narrative? Thanks, Elaine Wild Environmental Engineer Division of Water Resources - Raleigh Regional Office North Carolina Department of Environmental Quality 919.791.4254 Office elaine.wild(@deq.nc.gov Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to thud parties. Sewer Extension Permitting I NC DEQ subchapter t rules.pdf(state.nc.us) From: Sweater, Jeff<isweater(@La Bella PC.com> Sent:Tuesday, November 28, 2023 12:11 PM To: Wild, Elaine <elaine.wild(@deq.nc.gov>; Allen, Isaac I <isaac.allen(@deq.nc.gov>; Chawla, Sharan <sharan.chawla(@deg.nc.gov>; Fayad, Abdulrahman B<abdulrahman.fayadPc1eq.nc.gov>; Wilson, Susan A<susan.wilson(@deq.nc.gov> Cc: Houston, Brian <bhouston(@LaBellaPC.com>; Douglas, Ryan <rddouglas(CDLa Bella PC.com>; Prunchak, Eric<eprunchak(@La Bella PC.com>; Lockhart, Allen <blockhart(@cityofroxboro.com>; Rachel.A.Capito(@usace.army.mil; Thomas, Zachary T<zachary.thomas(@deq.nc.gov>; Lentz, Zac <zac.lentz(@deq.nc.gov> Subject: RE: [External] Permits for The Roxboro Western Sewer Extension Project (PERSO-2024-003) CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Elaine, Please see my comments below in green. Thanks, Jeff Sweater, PE LaBella Associates I Senior Project Manager 0 704-941-2143 direct 704-376-6423 office 941-374-3930 cell 400 S.Tryon St,Suite 1300 Charlotte, NC 28285 labellaac.com From: Wild, Elaine <elaine.wildPdeq.nc.gov> Sent: Monday, November 27, 2023 4:25 PM To: Sweater, Jeff<isweater(@LaBellaPC.com>; Allen, Isaac I <isaac.allen(@deq.nc.gov>; Chawla, Sharan <sharan.chawla(@deq.nc.gov>; Fayad, Abdulrahman B<abdulrahman.fayad(@deq.nc.gov>; Wilson, Susan A<susan.wilson(@deq.nc.gov> Cc: Houston, Brian <bhouston(@LaBellaPC.com>; Douglas, Ryan <rddouglas(@La Bella PC.com>; Prunchak, Eric<eprunchak(@La Bella PC.com>; Lockhart,Allen <blockhart(@cit)lofroxboro.com>; Rachel.A.Capito(@usace.army.mil; Thomas, Zachary T<zachary.thomasPdeq.nc.gov>; Lentz, Zac <zac.lentz(@deq.nc.gov> Subject: RE: [External] Permits for The Roxboro Western Sewer Extension Project (PERSO-2024-003) Hello Jeff, Thank you for the updated FTA and USE forms received on November 1, 2023. Since our last conversation, I have been working with internal staff on ensuring that the project meets the requirements for Fast Track Sewer Extension Permitting. There are still a few items that need to be addressed: 1. Regarding 401/404 submissions: Eric Prunchak from our Environmental Dept will look into these comments and response back to Rachel and copy you as necessary. a. Please confirm that the project has met the 401 Pre-Application submittal requirement to the Division of Water Resources. This is achieved by providing the confirmation email from NCDEQ. b. If it has been 30 days since pre-application requirements have been met, please resubmit the 401 Application. Once completed, please provide the DWR#to me. c. Please respond to Rachel at the USACE regarding her RFAI. 2. Additionally, the current aerial crossing for the project does not meet the Minimum Design Criteria for Gravity Sewers (MDCGS). Please review the MDCGS and demonstrate/explain how the crossing meets Section V.F. of the MDC, link provided below for your convenience. If the project is unable to meet the MDCGS, then the project would be forwarded to Central Office for full plan review. From Section V.F of the MDCGS manual (and as discussed in the attached email when we were initially trying to determine if this could be processed as FTA): F. Aerial Crossings 1. Proper joint technology, such as flanged or restrained,adequate supports to prevent excessive flexion,or a combination of both shall be provided for all aerial pipe crossings. Supports shall be designed to prevent frost heave, overturning,and settlement. 2. Precautions against freezing, such as insulation and increased slope, shall be provided. Expansion jointing shall be provided between above ground and below ground sewers. Where buried sewers change to aerial sewers,special construction techniques shall be used to minimize heaving. 3. For aerial stream crossings, the impact of flood waters and debris shall be considered. The bottom of the pipe should be placed no lower than the elevation of the 25 year flood. Ductile iron pipe with mechanical joints shall be required. In the event that the 25 year flood elevation can not be determined or the proposed gravity sewer must be placed below the 25 year flood elevation,a letter shall be provided by the applicant upon certification stating: "Regular and proper inspection and maintenance of the aerial crossing shall be provided to insure that the creek/stream flow is not impeded and that no damage will be caused to upstream or adjacent properties." The aerial crossing invert will be below the 25-year flood elevation. Based on V.F.3, it appears to me that still meet the MDCGS aerial crossing criteria if provide a letter from the Applicant (the City) as part of the construction certification at project completion stating "Regular and proper inspection and maintenance for the aerial crossing shall be provided to ensure that the creek/stream flow is not impeded and that no damage will be caused to upstream or adjacent properties." This appeared to be the only issue that had the potential conflict with the MDCSG requirements and would have prevented this project from using the FTA and me being able to certify that to the best of my knowledge, the design meets all requirements of the MDCSG. Do I need to include this in a narrative or have the City provide the certification now? The requirement states the letter shall be provided by the applicant upon certification, which took to mean an engineer's certification of completion at the end of the project prior to DEQ authorizing the new sewer system for use based on some of the other references used in the MDCSG. But if providing the letter now resolves this issue and allows the FTA to still be utilized as DEQ essentially directed me to use over the SSEA I initially submitted in August based on this matter, we have the City get that over to you. Please let me know if there is any format, template, or wording that needs added to this applicant's certification, other than what is shown in V.F.3, and if it needs to be notarized. Application Forms & Help Documents I NC DEQ Gravity Sewer Minimum Design Criteria Please provide the requested information by December 15, 2023. Sincerely, Elaine Wild Environmental Engineer Division of Water Resources- Raleigh Regional Office North Carolina Department of Environmental Quality 919.791.4254 Office elaine.wild(@deq.nc.gov D Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Sewer Extension Permitting I NC DEQ subchapter t rules.pdf(state.nc.us) From: Sweater,Jeff<jsweater(@La Bella PC.com> Sent: Monday, November 27, 2023 9:32 AM To: Wild, Elaine<elaine.wild(@deq.nc.gov>; Allen, Isaac I <isaac.allen(@deq.nc.gov>; Chawla, Sharan <sharan.chawla(@deg.nc.gov>; Fayad, Abdulrahman B<abdu1rahman.fayad(@c1eq.nc.gov>, Wilson, Susan A<susan.wilson(@deq.nc.gov> Cc: Houston, Brian <bhouston(@LaBellaPC.com>; Douglas, Ryan <rddouglas(@La Bella PC.com>; Prunchak, Eric<eprunchak(@La Bella PC.com>, Lockhart, Allen <blockhart(@cit)lofroxboro.com> Subject: [External] Permits for The Roxboro Western Sewer Extension Project (PERSO-2024-003) CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. All, I wanted to verify if DEQ has everything they require for the 401/404 and DWR sewer extension permit technical reviews, and are currently in the process of being generated, if any are required. The only outstanding comments I'm aware of are from the attached email. These were addressed and the original applications were resubmitted on 11/14/2023 as per the delivery notification below (see draft copies of revised applications). I tried to get guidance from Elaine Wild multiple times prior to resubmitting, but she never got back to me. I'm wondering if she is still with DEQ since she was super responsive prior to her comments being emailed on 10/19/23? Please verify that someone at DEQ has received these revised DWR applications and that things are moving forward in the right direction. Tracking Number: E1031379844US (D Copy Add to Informed Delivery G Delivered Scheduled Delivery by Delivered,In/At Mailbox RALEIGH,NC 27609 T U ES D AY November 14,2023,2 pm 14 by 9eeAlTreebnHisto" November 2023 QI 6:00pm O What Do LISPS Tracking Statuses Mean? Your item was delivered in or at the mailbox at 2:47 pm on November 14,2023 in RALEIGH,NC 27609.Waiver of signature was exercised at time of delivery. Get More Out of USPS Tracking: M USPS Tracking Plus Thanks, Jeff Sweater, PE La Bella Associates I Senior Project Manager 0 J 704-941-2143 direct 704-376-6423 office 941-374-3930 cell 400 S.Tryon St,Suite 1300 Charlotte, NC 28285 labellapc.com From: Sweater,Jeff Sent:Thursday, October 19, 2023 3:12 PM To: Fayad, Abdulrahman B<abdulrahman.fayad(@deq.nc.gov>; Wild, Elaine <elaine.wild(@deq.nc.gov>; Lockhart, Allen <blockhart(@cityofroxboro.com> Cc:Allen, Isaac I <isaac.allen(@deq.nc.gov>; Houston, Brian <bhouston(@La Bella PC.com>; Douglas, Ryan <rddouglas(@La Bella PC.com>; Chawla, Sharan <sharan.chawla(@deq.nc.gov>; Prunchak, Eric <earunchak(@LaBeIIaPC.com> Subject: RE: [Ext] 401/404 Permits for The Roxboro Western Sewer Extension Project (PERSO-2024- 003) Good afternoon Abdulrahman, Attached is the Application and Narrative for the wetlands permitting. Please note that the entire package with the wetlands report is 150 MB. If anyone wants the entire submission package, please let me know and I'll set up an FTP site link for download. The size of this document has created some issues thus far. Thanks, Jeff Sweater, PE La Bella Associates I Senior Project Manager 0 ., 704-941-2143 direct 704-376-6423 office 941-374-3930 cell 400 S.Tryon St,Suite 1300 Charlotte, NC 28285 labellapc.com From: Sweater,Jeff<jsweater(c�labellapc.com> Sent:Thursday, October 19, 2023 10:33 AM To: Fayad, Abdulrahman B<abdulrahman.fayad(@deq.nc.gov>; Wild, Elaine <elaine.wildPdeq.nc.gov>; Lockhart, Allen <blockhart(@cit)lofroxboro.com> Cc:Allen, Isaac I <isaac.allen(@deq.nc.gov>; Houston, Brian <bhouston(@La Bella PC.com>; Douglas, Ryan <rddouglas(@La Bella PC.com>; Chawla, Sharan <sharan.chawla(@deg.nc.gov>; Prunchak, Eric <earunchak(@LaBellaPC.com> Subject: RE: [Ext] 401/404 Permits for The Roxboro Western Sewer Extension Project (PERSO-2024- 003) Good morning Abdulrahman, I'll email these applications over today. We are having server issues this morning, so it may not be until this afternoon. But the application number is SAW-2023-01579 for the 401 permit. Do you want the full submission package for each, or just a copy of the signed and submitted Application only for each? Let me know if you need paper copies. Thanks, Jeff Sweater, PE La Bella Associates I Senior Project Manager u J 704-941-2143 direct 704-376-6423 office 941-374-3930 cell 400 S.Tryon St,Suite 1300 Charlotte, NC 28285 labellapc.com From: Fayad, Abdulrahman B<abdulrahman.fayad(@deq.nc.gov> Sent: Wednesday, October 18, 2023 3:29 PM To: Wild, Elaine <elaine.wildC@deq.nc.gov>; Lockhart, Allen <blockhart(@cityofroxboro.com> Cc: Sweater, Jeff<isweaterPlabellapc.com>; Allen, Isaac I <isaac.allen(cDdeq.nc.gov>; Houston, Brian <bhouston(@LaBellaPC.com>; Douglas, Ryan <rddouglas(@La Bella PC.com>; Chawla, Sharan <sharan.chawla(@deq.nc.gov> Subject: [Ext] 401/404 Permits for The Roxboro Western Sewer Extension Project (PERSO-2024-003) Hello Allen, I'm requesting a copy of the 404 and a copy of the 401 applications. If you have submitted a 401 application from the Division of Water Resources, you should have been provided with a permit number or project ID. Thank you, Abdulrahman Fayad ARPA Engineer II- RRO Division of Energy, Mineral, and Land Resources Department of Environmental Quality 919-791-4210 (office) 919-571-4718 (fax) Abdulrahman.Fayad(cDncdenr.gov Physical Address: 3800 Barrett Drive Raleigh, NC 27609 Mailing Address: 1628 Mail Service Center Raleigh, NC 27699-1612 D- E OOpaMwnq of Envirunma�Ll pual�ry Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties by an authorized state official. CAUTION: This email originated from outside the LaBella organization. Do not click links or open attachments unless you recognize the sender and know the content is safe.