HomeMy WebLinkAboutNC0021601_Annual Report_20240227Town of Tryon Wastewater Treatment Plant 301 N. Trade Street Tryon, N.C. 28782 February 12, 2024 Octavio Henriquez, Pretreatment Coordinator PERCS-Pretreatment NC Division of Water Resources 1617 Mail Service Center Raleigh, N.C. 27699-1617 Subject: 2023 PAR Dear Mr. Henriquez: Please find enclosed the following: • Pretreatment Program Info Database form • PAR Narrative • Compliance Judgment Spreadsheet • Pretreatment Performance Summary (PPS) • Significant Non -Compliance Report (SNCR) • SIU and POTW Data Summary Forms (IDSF) • Allocation Table • Land applied Class B Biosolids • Proposed action for significant noncompliance RECEIVED FY=i3 2 7 2024 NCDEQ/DWR/NPDES We will continue to work with our SIU to maintain a compliant 2024 year. If you have questions, please contact me at debmbradley@hotmail.com. Sincerely, CaAA� a&)&4A-1. Deborah Bradley Pretreatment Coordinator Tryon WWTP [-1LGWX about:blank Pretreatment Program Info Database for Program Name Tryon WWTP Name Town of Tryon Program Approval Date 01/01/1985 Pretreatment Status Modified Region ARO County Polk NPDES Number NCO021601 printed on: 12/22/2023 stream information -1k IWC % at 7Q10 36.73 7010 Flow cfs / mgd 4 / 2.58 1Q10 Flow cfs / mgd 3.34 / 2.16 Stream Classification C Basin Number BRD06 Receiving Stream Name VAUGHN CREEK NPDES Effective Date 08/01/2020 Last PAR Rec 02/16/2022 PAR Due Date03/01/2023 mercury NPDES Expire Date P� 12/31/2024 Current Fiscal 03/16/2020 1631 required q Year PC[ Done POTW is Primary WWTP TRUE Last Audit on 05/19/2016 Audit Year Nex120/21 es Design Flow mgd 1.5000 %Design mgd is SIU permitted 11.67 Permitted SIU flow (mgd) [Pt_SIU) •175 WWTP SIU's 1 Program SIUs 1 WWTP CIU's 0 Program CIUs 00 HWA `F LIMP WVS suo ERP date Inactive Date Next Due 05/01/2023 Date Received by DWR 09/18/2023 12/05/2017 05/30/2018 01/22/2013 06/01/2020 Date Approved 01/29/2018 06/06/2018 04/02/2013 09/02/2020 Adopt Date Required Date Adopted 05/21/2013 Info in this Box from Pt Contacts Date Date Date PT_Pro Attended Attended Attended Formal Name o_Prima Phone1 out ate.. Ms. Deborah Bradley Prim 28 859-5626 1828 859-5934 --•--•--^-r v.-rrnaN rnI%vvnsN 1/17/2007 Debmbradley@hotmail.com Wastewater Plant Supervisor 301 N. Trade Street 28782 DWR Central Office Contact Pretreatment Staff DWR Regional Contact elanie Kemp if 1 1 MA/7Mn i n.,Ni • . . Tryon Wastewater Plant NPDES Permit No. NC0021601 2023 PAR Narrative Tryon Finishing Corporation: IUP #001 General Information: • Tryon Finishing Corporation is SNC for copper. • 4/13/23 TFC non -compliant for copper. • 7/13/23 TFC non -compliant for copper. • 10/4/23 TFC non -compliant for copper. • 10/4/23 POTW split sample, also non -compliant for copper. • 11/28/23 POTW re -sampled for copper/non-compliant for copper. • 10/31/23 POTW conducted an annual inspection at Tryon Finishing Corporation. • POTW Advertised Public Notices in local paper for Copper Violations for periods January — June 2023 and July — December 2023. • Land applied Class B Biosolids • Proposed action taken by SIU to prevent significant noncompliance is requesting the POTW modify the SIU permit to decrease the flow from 0.175 MGD to 0.0875 MGD and increase copper limits from 0.24 mg/L to 1.0 mg/L. Industry Name: Tryon Finishing Corp. IUP #/Pipe # I Reporting Period:,E 2023 Detection Level (DQ entered Yes Level (UL) entered Type - Sample Date P=POTW Permit Limit TRC Limit Average of Column Total Samples Compliance judgement PAR 2023, SIU # 2/6/2024, 8:57 AM Compliance judgement PAR 2023 Instructions - 1) Data entry in blue bordered cells only. All other cells protected. Password is 3. Strongly Recommend only unprotect to make specific changes, and the reinstate protection again. 2) For data reported as "Below Detection," choose either to enter detection level or 1/2 detection level and mark choice in cell B5. (Note use second option only when detection level at or below limit) NOTE- Spreadsheet corrected Feb 09 to properly assess TRC violations using "equal to or greater than". `Flow: Chronic (>=66%) and TRC (>=33%) SNC definitions use term "pollutant," so technically not required to apply to flow "pH: TRC (>=33%) SNC definition specifically exempts pH. -Not required to apply Chronic or TRC SNC to flow Daily Flow Violation < Concentration ation Violation < Concentration ily Violation MGD Type mg/L Type mg/L Type 0.175 �— 300 160 0.210 Optional' 420.0001 224 Reg TRC Reg TRC 5 0 0 % Violations* 0.0% % TRC Violations' 0.0% *SNC ? NO 0 4 0 0 0 % Violations 0.0% % TRC Violations 0.0% SNC ? NO Page 1 4 0 0 % Violations 0.0% % TRC Violations 0.0% SNC ? NO Industry Name: Tryon Finishing Corp. IUP #/Pipe # 1 Reporting Period: 2023 uetection Levei (DL) entered Yes Level entered Type - Sample Date P=POTW Permit Limit TRC Limit 1/12/2023 3/15/2023 4/13/2023 7/13/2023 10/4/2023 10/4/2023 C11 /28/2023 I�:] I_�::] I� 1 P� F� Average of Column Total Samples Compliance judgement PAR 2023, SIU # 2/6/2024, 8:57 AM Compliance judgement PAR 2023 rdno n'i nnnlw to n" •AMMONIA < Concentration ily Violation Daily Grab Violation < Con oily Concentration Violation mg/L Type SU Type mg/L Type 5.0 - 11.0114 �1 #VALUE! Reg TRC Reg Reg TRC -I -I 0 0 0 0 % Violations % TF % TRC Violations SNC ? 7 0 % Violations 0.0% o " SNC ? Page 2 M -__ -__ -__ -__ 0 0 0 0 % Violations % TRC Violations SNC ? Industry Name: Tryon Finishing Corp. IUP #/Pipe # �— 1 Reporting Period:,L_ 2023 uetection Levei (DL) entered Yes Levei (uL) entered Type - Sample Date P=POTW (- Permit Limit TRC Limit Ave 1 /12/2023 01 3/15/2023 0 4/13/2023 0 7/13/2023 0 10/4/2023 0 10/4/2023 11 /28/2023 raae of Column Total Samples Compliance judgement PAR 2023, SIU # 2/6/2024, 8:57 AM Compliance judgement PAR 2023 CHROMIUMARSENIC CADMIUM Daily Violation Violation Daily Daily Violation TT < Concentration < Concentration < Concentration mg/L YPe mglL ype mg/L Type Ell =1 Reg TRC Reg TRC 0 1 0 % Violations 0.0% % TF % TRC Violations 0.0% SNC ? NO 0 0 1 0 % Violations 0.0% % TRC Violations 0.0% SNC ? NO Page 3 W 0 1 0 0 % Violations 0.0% % TRC Violations 0.0% SNC ? NO Industry Name: Tryon Finishing Corp. IU P #/Pipe #1 1 Reporting Period: 2023 11 Uetection t_evei (DL) entered Yes Level (UD) entered Type - Sample Date P=POTW Permit Limit TRC Limit 7 Average of Column Total Samples Compliance judgement PAR 2023, SIU # 2/6/2024, 8:57 AM Compliance judgement PAR 2023 •-•CYANIDE� Daily Violation Daily Violation Daily Violation < Concentration TT < Concentration < Concentration mg/L Type mg/L Type mg/L Type 0.241 I[—]E----]1 E:10 0.288 Reg TRC Reg TRC Reg TRC E:11 0.139 0 0 0.28 0 0.56 0 0.33- 0 0.334 =1 365 00 00 =0 =0 0.3353 0 6 5 4 0 1 0 0 0 1 0 0 % Violations 83.3% % Violations 0.0% % Violations 0.0% % TF % TRC Violations 66.7% % TRC Violations 0.0% % TRC Violations 0.0% SNC ? YES SNC ? NO SNC ? NO Page 4 Industry Name: Tryon Finishing Corp. IUP #/Pipe # 1 Reporting Period: 2023 ]1 uetection t_evei (DL) entered Yes Levei (uL) entered Type - Sample Date P=POTW Permit Limit TRC Limit 7; Average of Column Total Samples Compliance judgement PAR 2023, SIU # 2/6/2024, 8:57 AM Compliance judgement PAR 2023 MOLYBDENUMMERCURY Daily Violation Daily Daily Violation TT < Concentration < Concentration Violation < Concentration mg/L YPe mg/L YPe mg/L Type Reg TRC Reg TRC Reg TRC 0 5 0 % Violations 0.0% % TF % TRC Violations 0.0% SNC ? NO 0 0 0 0 0 % Violations % TRC Violations SNC ? Page 5 0 1 0 % Violations 0.0% % TRC Violations 0.0% SNC ? NO M Industry Name: Tryon Finishing Corp. IUP #/Pipe # 1 Reporting Period: 20231 uetection Levei (DL) entered Yes Levei (uL) entered Type - Sample Date P=POTW Permit Limit TRC Limit 1 3/15/202311 1 4/13/2023 0 7/13/2023 11 Average of Column Total Samples Compliance judgement PAR 2023, SIU # 2/6/2024, 8:57 AM Compliance judgement PAR 2023 • Daily Violation Daily Violation Daily Violation < < Concentration Concentration < Concentration mg/L Type mg/L Type mg/L Type Reg TRC Reg TRC M��Mm� MM U U U U % Violations % TF % TRC Violations SNC ? 0 0 % Violations % TRC Violations SNC ? Page 6 0 0 0 1 0 % Violations 0.0% % TRC Violations 0.0% SNC ? NO 0 Industry Name: Tryon Finishing Corp. IUP #/Pipe #1 1 Reporting Period: 2023 uetection t-evei (DL) entered Yes Levei (uL) entered Type - Sample Date P=POTW Permit Limit TRC Limit Ave 1 /12/2023 0 3/15/2023 - 4/13/2023 7/13/2023 0 10/4/2023 0 10/4/2023 11 /28/2023 raae of Column Total Samples Compliance judgement PAR 2023, SIU # 2/6/2024, 8:57 AM Compliance judgement PAR 2023 Phosphorus. . Daily Daily Daily < Concentration Violation < Concentration Violation < Concentration Violation mg/L Type mg/L Type mg/L Type 0.24 Rea TRC Rea TRC Req TRC U 5 U % Violations 0.0% % TF % TRC Violations 0.0% SNC ? NO 0 0 1 0 % Violations 0.0% % TRC Violations 0.0% SNC ? NO Page 7 -__ M��__ -__ -__ -__ -_m . mm M mm -�_ : 0 0 1 0 0 % Violations 0.0% % TRC Violations 0.0% SNC ? NO Industry Name: Tryon Finishing Corp. IU P #/Pipe # 1 Reporting Period: 2023 uetection Levei (DL) entered Yes t_evei (ut_) entered Permit Limit TRC Limit Ave Type - Sample Date P=POTW , I - 1 /12/2023 0 3/15/2023 0 4/13/2023 0 7/13/2023 10/4/2023 0 10/4/2023 11 /28/2023 raae of Column Total Samples Compliance judgement PAR 2023, SIU # 2/6/2024, 8:57 AM Sulfate Daily Violation < Concentration mType g/L 00 Reg TRC 0 1 0 0 % Violations 0.0% % TRC Violations 0.0% SNC ? NO Compliance judgement PAR 2023 Page 8 Chapter 9, PAR Guidance Pretreatment Performance Summary (PPS) 1. Pretreatment Town Name: Town of Tryon 2. "Primary" NPDES Number NC00 21601 or Non -Discharge Permit # if applicable => 3. PAR Begin Date, please enter 01/01/yyyy 3. => 1/1/2023 4. PAR End Date, please enter 12/31/yyyy 4. => 12/31/2023 5. Total number of SIUs, includes CIUs 5. => 1 6. Number of CIUs 6. => 0 7. Number of SIUs with no IUP, or with an expired IUP 7. => 0 8. Number of SIUs not inspected by POTW 8. => 0 9. Number of SIUs not sampled by POTW 9. => 0 to. Number of SIUs in SNC due to IUP Limit violations 10. => 1 11. Number of SIUs in SNC due to Reporting violations 11. => 0 12. Number of SIUs in SNC due to violation of a Compliance Schedule, CO, AO or similar 12. => 0 13. Number of CIUs in SNC 13. => 0 14. Number of SIUs included in Public Notice 14. => 1 15 Total number of SIUs on a compliance schedule, CO, AO or similar 15. => 0 16. Number of NOVs, NNCs or similar assesed to SIUs 16. => 3 17. Number of Civil Penalties assessed to SIUs 17. => 0 18. Number of Criminal Penalties assessed to SIUs 18. => 0 19. Total Amount of Civil Penalties Collected 19. => $ 0 20. Number of IUs from which penalties collected 20. => 0 [Notes: AO Administrative Order IUP Industrial User Pretreatment Permit POTW CIU Categorical Industrial User NNC Notice of Non -Compliance SIU Publicly Owned Treatment Works Significant Industrial User CO Consent Order NOV Notice of Violation SNC Significant Non -Compliance IU Industrial User PAR Pretreatment Annual Report revised 1/2018: PAR PPS 2018 Pretreatment Annual Report (PAR) Significant Non -Compliance Report (SNCR) WWTP = Wastewater Treatment Plant, use separate form for each WWTP. SILT = Significant Industrial User SNC = Significant Non -Compliance PAR covers this calendar year => Control Authority--Program--Town Name => WWTP Name => NPDES # _> A SNCR Form must be submitted with every PAR, please write "None " if you had No SIUs in SNC during calendar year IUP # Pipe # Industry Name Parameter or "Reporting" SNC ? ( Yes / No) for each 6-month period. Jan. - June July -Dec. 1 1 Tryon Frinishing Corporation Copper Yes Yes Attach a copy of the Division's "SIUs in SNC Historical Report" for your POTW's SIUs behind this page. Is the database correct ? Notify the Division of any errors ! Database indicates SNC history for previous years. EVERY SNC MUST be explained in the Narrative, How was, is, or will it be resolved? REPEAT SNCs are serious matters that MUST be explained in the Narrative. Form name: PAR SNCR 2001 Date Revised: 1/4/2001 2023 Tryon Tryon NCO021601 Pretreatment Annual Report (PAR) Control Authority, Industry Industrial Data Summary Form (IDSF) Town Name => Tryon Name Tryon Finishing Corp Use separate forms for each industry/pipe WWTP Name => ryon IUP # 1 Enter BDL values as < (value) NPDES # _> 21601 Pipe #_ 1 1st 6 months, dates => to 6/30/2023 2nd 6 months, dates => 7 1 2023 to 12 31/23 Total # of samples => * Maximum (mg/1) _> * or Maximum (1b/d) _> * or Average (mg/1) _> * or Average Loading (lb/d) _> _ % violations,(chronic SNC is >= 66%) _> % TRC violations, (SNC is >= 33 %) _> % violations,(chronic SNC is >= 66%) _> % TRC violations, (SNC is >= 33 %) _> Total # of samples => * Maximum (mg/1) _> * or Maximum (lb/d) _> * or Average (mg/1) _> * or Average Loading (lb/d) _> _ % violations, (chronic SNC is >= 66%) _> % TRC violations, (SNC is >= 33 %) _> A % violations,(chronic SNC is >= 660%) _> % TRC violations, (SNC is >= 33 %) _> Total # of samples => * Maximum (mg/1) _> * or Maximum (lb/d) _> * or Average (mg/1) _> * or Average Loading (lb/d) _> _ % violations, (chronic SNC is >= 66%) _> % TRC violations, (SNC is >= 33 %) _> a % violations,(chronic SNC is >= 66%) _> % TRC violations, (SNC is >= 33 %) _> istomontlis n mon s s mon s 2naomontlis Istomontris 2naomontlis Ist6montris n mon1tns 1 4 2 2 2 3 0.057 0.0093 200 260 93 120 0 0 0.00'/0 0 0 0 0 0 0.00%1 01 01 0 renic amium chromium ium s mon s s n months- s n months st months12ndmon ssmon I <0.01 01 0 0 0 01 1 51 1 0 opper Uyanide ea ercury st 6 months 2nd 6 months I st 6 months 2nd 6-months s mon s 2nd 6 months s mon s 2nd 6 months 2 4 1 1 2 3 0.28 0.365 <0.005 0.001 0.0006 0.0005 0.2 0.39 0 66.70% 0 0 1 0 0 0 0.00% 0 0 0 0 BDL — Below Detection Limit mg/I => milligrams per liter • POTW must enter at least one of these IUP => Industrial User Permit lb/d => pounds per day four rows, Please indicate how averages were calculated SNC => Significant Non -Compliance mgd => million gallons per day Avg period could be month, Qtr, or 6-month & if BDL, 1/2BDL, or zero values used. TRC => Technical Review Criteria WWTP => wastewater treatment plant Chapter: PAR Guidance File name: PA(ktHpMmkide%Gaiude¢EfflhaotqLWskctgRM, pages 12, 13, 14 Blank IDSF Form, Copy and use in your PAR Number each set for each IUP pipe -Page of 2. Pretreatment Annual Report (PAR) Industrial Data Summary Form (IDSF) Use separate forms for each industry/pipe Total # of samples => * Maximum (mg/1) => * or Maximum (lb/d) => * or Average (mg/1) => * or Average Loading (lb/d) => % violations, (chronic SNC is >= 66%) => % TRC violations, (SNC is >= 33 %) => % violations, (chronic SNC is >= 66%) => % TRC violations, (SNC is >= 33 %) => Total # of samples => * Maximum => * or Minimum => % violations, (chronic SNC is >= 66%) => % TRC violations, (SNC is >= 33 %) => % violations, (chronic SNC is >= 66%) => % TRC violations, (SNC is >= 33 %) => Total # of samples => * Maximum (mg/1) => * or Maximum (lb/d) => * or Average (mg/1) => * or Average Loading (lb/d) => % violations, (chronic SNC is >= 66%) => % TRC violations, (SNC is >= 33 %) => % violations, (chronic SNC is >= 66%) => % TRC violations, (SNC is >= 33 %) => Industry Name Tryon Finishing Corporation IUP # I Pipe # I lkj Iy %< - haram i - r.� I ►�c - r�l I t rIjil-mg.MtiM rrr�.TT•Siiiii7 r�l<. iTiTiiiiii� rrra. iiii��I 'Ii .TTt =1d r0L� SIIII rrrr� 10ME2E a rrrrrrs�li� rErrr.SIIII rrrr, i?'iTiTiilitIII III ME 'TtTiiiil7 rrrr.TiT.Tifii 1 BDL => Below Detection Limit mg/I => milligrams per liter * POTW must enter at least one of these IUP => Industrial User Permit lb/d => pounds per day four rows, Please indicate how averages were calculated SNC => Significant Non -Compliance mgd => million gallons per day Avg period could be month, Qtr, or 6-month & if BDL , 1/2BDL, or zero values used. TRC => Technical Review Criteria WWTP => wastewater treatment plant Chapter: PAR Guidance File name: pages 12, 13, 14 Blank IDSF Form, Copy and use in your PAR Number each set for each IUP pipe - Page -:L of 2— POTW== NPDES#=: IUP Count 2 3 4 5 6 7 8 9 10 Workbook Name: Allocation Table 2023 PAR, Worksheet Name: AT Printed: 2/6/2024, 9:24 AM Page 1 of 5 Allocation Table Headworks last approved: 08/15/18 Allocation Table updated: 02/06/24 Permits last modified: 01/01/18 Tryon WWTP NCO021601 Spreadsheet Instructions: 1) Applicable Values should be entered in the Heavy Bordered cells. Rest of worksheet is protected, password is „2„ 2) Formulas are discussed in the Comprehensive Guidance, Chapter 6, Section C. 3) HWA and AT worksheets in this workbook are linked. Pollutant Names, MAHLs, Basis, and Uncontrollable load in this AT worksheet are automatically entered from the HWA spreadsheet. This includes pollutant names in columns AT through BK. Type Renewal Modification Date Pipe of Effective Effective Permit number Industry Date Date Expires FLOW Permit Limits BOD Permit Limits TSS Permit Limits Industry INDUSTRY NAMES Permit (ply list alPnabcuay) number MGDgal/day Conc. Load m lbs/da Conc. Load m lbs/da Tryon Finishing Co oration 0001 0001 Textile 01/01/22 01/01/18 12/31/27 0.1750 175,000 300.00 437.85 160.00 233.52 Column Totals => 1 0.17501 175,0001 438 234 Basis=> MAHL from HWA (lbs/day) => NPDES Permitted Flow=> Uncontrollable Loading (lbs/day) => Total Allowable for Industry (MAIL) (Ibs/day) => Total Permitted to Industry (Ibs/day) => MAIL left (lbs/day)=> Percent Allow. Ind. (MAIL) still available (%) => Percent MAHL still available (%) => 5 Percent MAHL (lbs/dav) => NPDES Design Design 1.5000 2189 2502 0.1900 208 297 1.3100 1981 2205 0.1750 438 234 1.1350 1543 1971 86.6 % 89.4 75.7 % M109 78.8 0.0750 125 H WA.AT Revised: November 2005 POTW. NPOESO�: IUP Count 1 2 3 4 5 6 7 8 9 10 Workbook Name: Allocation Table 2023 PAR, Worksheet Name: AT Allnratinn Tahle I Printed: 2/6/2024, 9:25 AM Page 2 of 5 Headworks last approved: Allocation Table updated: Permits last modified: 08/15/18 Pipe number 02/06/24 01/01/18 Tryon WWTP NCO021601 Industry INDUSTRY NAMES Permit c na.gmb-y> number Ammonia Permit Limits Arsenic Permit Limits Cadmium Permit Limits Chromium Permit Limits Copper Permit Limits Cyanide Permit Limits Cone. Load m lbs/da Cone. Load m lbs/da Conc. Load m lbs/dav Conc. Load mRA lbs/dav Cone. Load MgA lbs/da Cone. Load m lbs/da Trvon Finishine Corporation 0001 0001 0.2400 0.3503 Column Totals => 0 0.0000 0.0000 0.00001 1 0.3503 0.0000 AS/NitITF AS/Nit/TF AS/Nit/TF AS/Nit/TF AS/NWTF Basis- #VALUE! inhibition inhibition inhibition inhibition inhibition MARL from HWA (lbs/day) => 250.00 0.0343 0.0261 2.6350 1.2291 0.2635 Uncontrollable Loading (lbs/day) _> 21.78 0,0026 0.0003 0.0050 0.0078 Total Allowable for Industry (MAIL.) (Ibs/day) _> 228.22 0.0317 0.0258 2.6300 1.2213 ##### Total Permitted to Industry (lbs/day) _> 0.00 0.0000 0.0000 0.0000 0.3503 0.0000 MAIL left (lbs/day) => 228.22 0.0317 0.0258 2.6300 0.8710 ####### Percent Allow. Ind. (MAIL) still available (%) => 100.0 % 100.0 % 1 100.0 % 100.0 % 71.3 Percent MAHL still available (%) => 91.3 % 92.4 % 98.9 % 5 Percent MARL (]bs/dav) => 12.50 0.0017 0.0013 0.1318 0.0615 0.0132 HWA.AT Revised: November 2005 POTw= NPOES#- IUP Count 1 2 3 4 5 6 7 8 9 10 Workbook Name : Allocation Table 2023 PAR, Worksheet Name: AT Allnratinn Tnhla I Printed: 2/6/2024, 9:26 AM Page 3 of 5 Headworks last approved: Allocation Table updated: Permits last modified: 08/15/18 Pipe number 02/06/24 01/01/18 Trion WWTP NCO021601 Industry INDUSTRY NAMES Permit (p).x list a)phabeBcly) number Lead Permit Limits Mercury Permit Limits Molybdenum Permit Limits Nickel Petmit Limits Selenium Permit Limits Conc. Load MRA lbs/da Conc. Load m lbs/day Conc. Load rngA lbs/da Conc. Load m lbs/dav Conc. Load mgA ibs/da Trvon Finishing Corporation 0001 0001 Column Totals => 0.0000 0.000000 0.0000 0.0000 0.0000 AS/Nit/TF AS/Nit/TF AS/Nit/rF Basis=> inhibition inhibition inhibition MAHL from HWA (lbs/day) => 0.2834 0.006350 0.0468 0.2058 Uncontrollable Loading (Ibs/day) => 0.0052 0.000120 0.0024 0.0031 Total Allowable for Industry (MAIL) (lbs/day) _> 0.2782 0.006230 0.0444 0.2027 Total Permitted to Industry (Ibs/day) => 0.0000 0.000000 0.0000 0.0000 MAIL left (lbs/day) => 0.2782 0.006230 0.0444 0.2027 Percent Allow. Ind. (MAIL) still available (%) => 100.0 % 100.0 % 100.0 % 100.0 % Percent MAHL still available (%) => 98.2 % 9 8. 1 % 94.9 % 98.5 % 5 Percent MAHL (Ibs/day) _> 0.0142 0.000318 0.0023 0.0103 HWA.AT Revised: November 2005 0.0412 0.0043 0.0369 0.0000 0.0369 100.0 89.6 % .0021 m , r UJ c� o v m POTW=: NPDES#=: IUP Count 1 2 3 4 5 6 7 8 9 10 Workbook Name : Allocation Table 2023 PAR, Worksheet Name: AT Printed 2/6/2024, 9i27 AM Page 4 of 5 Allneatinn Tahlw Headworks last approved: Allocation Table updated: Permits last modified: 08/15/18 Pipe number 02/06/24 01/01/18 Tryon WWTP NCO021601 Industry INDUSTRY NAMES Permit (pl- listalpbebeWly) number Silver Permit Limits Zinc Permit Limits Total Nitrogen Permit Limits Total Phos. Permit Limits Chloride Permit Limits Sulfate Permit Limits Conc. Load m Ibs/da Conc. Load m lbs/da Conc. Load m lbs/da Conc. Load m lbs/da Conc. Load m lbs/da Conc. Load m lbs/da on Finishin Co ration 0001 0001 0.2000 0.2919 Column Totals => 0.0000 0.29191 0.00 0.00 AS/Nit/TF AS/Nit/TF Basis=> inhibition inhibition Design Design MARL from HWA (Ibs/day) => 0.6589 2.6354 187.6500 100.08 Uncontrollable Loading (lbs/day) => 0.1566 28.5000 3.83 Total Allowable for Industry (MAIL) (Ibs/day) _> ####### 2.4788 159.15 96.25 Total Permitted to Industry (lbs/day) _> 0.0000 0.2919 0.00 0.00 MAIL left (lbs/day) - ####### 2.1869 159.15 96.25 Percent Allow. Ind. (MAIL) still available (%) _> #######1 88.2%1 100.0 % 1 100.0 0 Percent MAHL still available (%) _> ####### 83.0 % 1 84.8%1 96.2 0 5 Percent MARL (lbs/davl => 0.0329 0.1318 1 9.38 5.0040 HWA.AT Revised: November 2005 Please run Public Notice Sunday October 22, 2023 in the Tryon Daily Bulletin and send an Affidavit of Publication to: Deborah Bradley Town of Tryon 301 N. Trade St. Tryon, N.C. 28782 PUBLIC NOTICE OF SIGNIFICANT INDUSTRIAL WASTEWATER PERMIT VIOLATIONS The Town of Tryon, in accordance with Federal and State Regulations is hereby giving Public Notice. Listed below is Significant Industrial User that were in significant noncompliance (SNC) with national pretreatment regulation, 40 CFR Part 403, and state pretreatment regulations, 15 NCAC 2H .0900, and local pretreatment regulations during the month of January thru June 2023: Tryon Finishing Corporation for Copper. A continuing effort is being made by the listed industry to achieve compliance. Deborah Bradley Town of Tryon Pretreatment Coordinator PUBLIC NOTICE OF SIGNIFICANT INDUSTRIAL WASTEWATER PERMIT VIOLATIONS The Town of Tryon, in accordance with Federal and State Regulations is hereby giving Public Notice. Listed below is Significant Industrial User that were in significant noncompli- ance (SNC) with national pretreat- ment regulation, 40 CFR Part 403, and state pretreatment regulations, 15 NCAC 2H .0900, and local pre- treatment regulations during the month of January thru June 2023: Tryon Finishing Corporation for Cop- per. A continuing effort is being made by the listed industry to achieve compli- ance. Deborah Bradley Town of Tryon Pretreatment Coordinator Tryon Daily Bulletin: Oct. 22, 2023 FLYERS/FOG Please run Public Notice Sunday December 31, 2023 in the Tryon Daily Bulleting and send an Affidavit of Publication to: Deborah Bradley Town of Tryon 301 N. Trade St. Tryon, N.C. 28782 PUBLIC NOTICE OF SIGNIFICANT INDUSTRIAL WASTEWATER PERMIT VIOLATIONS The Town of Tryon, in accordance with Federal and State Regulations is hereby giving Public Notice. Listed below is Significant Industrial User that was in significant noncompliance (SNC) with national pretreatment regulation, 40 CFR Part 403, and state pretreatment regulations, 15 NCAC 2H .0900, and local pretreatment regulations during the period of July thru December 2023. Tryon Finishing Corporation- For Copper A continuing effort is being made by the listed industry to achieve compliance. Deborah Bradley Town of Tryon Pretreatment Coordinator PUBLIC NOTICE PUBLIC NOTICE OF SIGNIFICANT INDUSTRIAL WASTEWATER PERMIT VIOLATIONS The Town of Tryon, in accordance with Federal and State Regulations is hereby giving Public Notice. Listed below is Significant Industrial User that was in significant noncompliance (SNC) with national pretreatment reg- ulation, 40 CFR Part 403, and state pretreatment regulations, 15 NCAC 2H .0900, and local pretreatment reg- ulations during the period of July thru December 2023. Tryon Finishing Corporation- For Copper A continuing effort is being made by the listed industry to achieve compli- ance. Deborah Bradley Town of Tryon Pretreatment Coordinator Tryon Daily Bulletin: Dec. 31, 2023 VIOLATIONS Publisher's Certificate of Publication STATE OF NORTH CAROLINA PUBLIC NOTICE COUNTY OF POLK PUBLIC NOTICE OF SIGNIFICANT INDUSTRIAL WASTEWATER PERMIT VIOLATIONS Kevin Powell, being duly sworn, says: That he is General Manager of the Tryon Daily The Town of Tryon, in accor- Bulletin, a daily newspaper of general circulation, dance with Federal and State Regulations is hereby giving printed and published in Tryon, Polk County, North Public Notice. Listed below is Carolina; that the publication, a copy of which is at- Significant Industrial User that tached hereto, was published in the said newspaper was in significant pli- on the following dates: ance (SNC) with nationalpre- treatment regulation. 40 CFR Part 403. and state pretreat- ment regulations, 15 NCAC 2H 12/31/23 .0900, and local pretreatment regulations during the period of July thru December 2023. Tryon Finishing Corporation - That said newspaper was regularly issued and For Copper circulated on those dates. A continuing effort is being made by the listed industry to The sum charged by the Newspaper for said achieve compliance. Deborah Bradley publication does not exceed the lowest rate paid Town of Tryon by commercial customers for an advertisement of Pretreatment Coordinator similar size and frequency in the same newspaper Tryon Daily Bulletin: in which the public notice appeared. Dec. 31. 2023 VIOLATIONS There are no agreements between the Tryon Daily Bulletin and the officer or attorney charged with the duty of placing the attached legal advertising notices whereby any advantage, gain or profit ccrued to said officer or attorney. SIGNED: Kevin Powell, General Manager Subscribed and sworn to before me this 31 st Day of December, 2023 so.. Mary Jo Eskridge, Notary Public �P.: State of Alabama at Large NOTARY My commission expires 03-02-2026 y Q PUBLIC m �gRGE Account # 141425 Ad # 1760537 _)WN OF TRYON 301 N TRADE ST TRYON NC 28782 Land Application for 2023 WQ Permit#: WQ0004341 Land Application Operator: Caroline Edwards/Town of Tryon • Total Number of application fields in the permit: 2 • Total number of fields utilized land application during the year: 2 • Total number of dry tons applied during the year for all application sites: 17 • Total number of acres utilizes for land application during the year: 14.08 • Facility was compliant during calendar year 2023 Firefox about:blank TRYON FIIJISHII�1rG January 18, 2024 Ms. Deborah Bradley Wastewater Plant Supervisor Town of Tryon North Carolina Via email: deb►nbradley0hotmail.com RE: Town of Tryon IUP #001 Dear Ms. Bradley: Thank you for taking the time to meet with me and Melanie Kemp at our plant in Tryon last month. As discussed, our company's current water flow into the Town of Tryon wastewater system is significantly lower than the permitted amount of up to 175,000 gallons per day. We would like to request a decrease in the amount of allowed flow along with an increase in the allowable amount of copper. As such, we would like to request that our maximum allowable flow rate be decreased by 50% to 87,500 gallons per day, and that the maximum allowable amount of copper tested be increased to 1.0 mg/liter. Per the allocation table you provided to Deborah, this would still leave more than 40% of Tryon's MAIL and MAHL still available. Thank you for your consideration of this matter. Please let me know if you have any questions or would like us to provide any further information. Best Regards, Naiden Kremenliev President 250 Screven Road I Tryon I North Carolina 128782 1 828-859-5891 1 of 1 2/19/2024, 9:55 AM