Loading...
HomeMy WebLinkAboutSW4240203_Supplement-EZ Form_20240226 DocuSign Envelope ID: DDF5ED55-7929-4EA0-997E-46BD1B56A123 ourrLCIVICIV I -CL I,.VVCI'C r'MI7C FORMS LOADED PROJECT INFORMATION 1 Project Name Hidden Woods Village 2 Project Area(ac) 15.529 3 Coastal Wetland Area(ac) 0 4 Surface Water Area(ac) 0.039 5 Is this project High or Low Density? Low 6 Does this project use an off-site SCM? No COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided(feet) 30 8 Will the vegetated setback remain vegetated? Yes 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 12 Bioretention Cell 13 Wet Pond 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 17 Rainwater Harvesting(RWH) 18 Green Roof 19 Level Spreader-Filter Strip(LS-FS) 20 Disconnected Impervious Surface(DIS) 21 Treatment Swale 22 Dry Pond 23 StormFilter 24 Silva Cell 25 Bayfilter 26 Filterra FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Alex Carter,PE 28 Organization: Beeson&Carter,PA 29 Street address: 4510 Reidsville Road 30 City,State,Zip: Winston Salem,NC 27101 31 Phone number(s): 336-748-0071 32 Email: acarter@bc-eng.com Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer ```��N�uC,An ,Ii,,�'' mac••,,.....,,•• O • off OESS1O • ▪ S• i a SEAL r � Signature of Designer 038574 ' •• LNGINEs /6-c �e ...... 2/15/2024 . inmiwn a�'��`` Seal Date DocuSign Envelope ID: DDF5ED55-7929-4EA0-997E-46BD1B56A123 UKAIIVHVC HKCHJ 1 Is this a high density project? No 2 If so,number of drainage areas/SCMs 0 3 Does this project have low density areas? Yes 4 If so,number of low density drainage areas 1 Is all/part of this project subject to previous rule 5 versions? , No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site LD 1 4 Type of SCM Vegetated Vegetated 5 Total drainage area(sq ft) 720023 720023 6 Onsite drainage area(sq ft) 720023 720023 7 Offsite drainage area(sq ft) 8 Total BUA in project(sq ft) 110050 sf 110050 sf New BUA on subdivided lots(subject to permitting) 9 (sq ft) 71400 sf 71400 sf New BUA not on subdivided lots(subject to 10 permitting)(sf) 38650 sf 38650 sf 11 Offsite BUA(sq ft) 12 Breakdown of new BUA not on subdivided lots: -Parking(sq ft) -Sidewalk(sq ft) -Roof(sq ft) -Roadway(sq ft) -Future(sq ft) -Other,please specify in the comment box below(sq ft) New infiltrating permeable pavement on 13 subdivided lots(sq ft) New infiltrating permeable pavement not on 14 subdivided lots(sq ft) Existing BUA that will remain(not subject to 15 permitting)(sq ft) 38650 sf — 38650 sf 16 Existing BUA that is already permitted(sq ft) 17 Existing BUA that will be removed(sq ft) 18 Percent BUA 15% 15% 19 Design storm(inches) 20 Design volume of SCM(cu ft) 21 Calculation method for design volume ADDITIONAL INFORMATION • Please use this space to provide any additional information about the 22 drainage area(s): See sheet C-4.0 for more details on drainage areas. Site has exempt paved streets paved in 2008(See email from Jim Farkas on determination)and is low density,using some road side ditches DocuSign Envelope ID: DDF5ED55-7929-4EA0-997E-46BD1B56A123 LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H.1003 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per.1003(2)(c)? Yes 4 Side slopes of the vegetated conveyances(H:V) 3:1 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 3.9 6 Are curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s)(%) _ 8 Bottom width of curb outlet swale(s)(feet) 9 Maximum side slope of curb outlet swale(s)(H:V) 10 Minimum length of curb outlet swale(s)(feet) _ 11 Are treatment swales used instead of curb outlet swales? 12 Is stormwater released at the edge of the setback as dispersed flow? Yes 13 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 Are variations to rule.1003 proposed? No ADDITIONAL INFORMATION 15 Please use this space to provide any additional information about this low density project: This site began developmetn in 2008-2009 and went dormant during the economic downturn. There are some existing side ditches as shsown on C-4.0 and the only existing pipe is a 48"RCP culvert installed at a drainage low point for the road construction. Pipes are proposed for the home driveway connections crossing side ditches. No additional pipes or conveyances beyond what was originally installed are planned to support the hoe construction phase of development. Drainage Pervious Swale Area BUA area C Q Slope Vallow Va«oa, Flow depth # (ac) (ac) (ac) (cfs) (%) (fps) (fps) (ft) 1 0.23 0.05 0.18 0.35 0.55 2.00 5.00 1.64 0.31 2 0.19 0.04 0.16 0.35 0.45 2.00 5.00 1.49 0.29 3 0.26 0.00 0.26 0.35 0.62 12.00 5.00 3.35 0.23 4 0.59 0.07 0.52 0.35 1.41 12.00 5.00 3.90 0.32 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30