Re: Review Comment Response
Brunswick County - Yancey Lane LPSS Extension WQ0045058
Project Name: Yancey Lane Sewer Extension
N&T Project No. 23081
Mr. Crisp,
We are responding to your emailed comments dated Monday, February 19, 2024, in red as
follows:
1. The proposed additional sewer flowrate requested in the permit application indicates
1,050 GPD based on 5 residential units (each 3 bedroom) at a flowrate of 210 GPD per
RDU. Please provide a copy of the design flow reduction approval letter for use of 210
GPD per RDU. For future reference, such approval letters are required to accompany
each permit application that is submitted to the Division for review if a reduced design
flowrate is proposed. The flow reduction letter is attached.
2. PE signed and sealed anti-floatation calculations were not submitted in support of the
notation on simplex pump station sheet C8 of the engineering plans. Please provide.
Anti-Floatation calculations are attached.
3. PE signed and sealed pump station emergency storage calculations were not submitted
as required in support of the notation on simplex pump station sheet C8 of the
engineering plans and indicated on the permit application that 360 gallons of storage is
available during a power outage. Please provide. The simplex grinder stations will be
installed by Brunswick County Public Utilities as homes are built. They use a Standard
Barnes Grinder Pump Station that requires 360 gallons of storage above the pump on
level. The pre-approval submitted overview of equipment Barnes Grinder Pump Station
is attached which requires this storage.
NCBELS License C-3641
H. Dale Crisp, P.E.
Review Comment Response
Yancey Lane LPSS Extension WQ0045058
N&T Project No. 23081
February 22, 2024
Page 2
A response to the above comments is considered required in order to proceed with the review
of the application and issuance of the permit. If a complete response is not received within 30
days, the application and supporting documents will be returned to you in accordance with 15A
NCAC 02T.0107(e)(2). We are responding within the 30 day response period for your
continued review. Please advise if anything additional is required.
Please feel free to provide digital copies of these revised documents and supporting
information to me via email along with hardcopies via mail. This response is being submitted
via email and hardcopies via Federal Express.
Thank you for your assistance with this project.
NORRIS & TUNSTALL
CONSULTING ENGINEERS, P. .
11, •
. Ph lip is, P.E.
PN/t w
'081 •2-22-24 swr-Itr-peres resp
cc: James Hodgin
NCBELS License C-3641
Density Soil 115 lb/cf Project: Yancey Lane Sewer Extension
Density Concrete 150 lb/cf NT# 23081
Well diameter 3.5 ft Date: 02-22-24
Well depth 7.0 ft
Well Volume=7.0 x it x 3.52 = 67.31 cf 000 "`11111.1�1"""1,��„�
vst CA/yn''�
Concrete Base Height _1.0 ft �'� - �,' ,'
Concrete Lip Height 0.5 ft •Y ''
Concretecc-
Base Diameter 5.5 ft
Base Volume= 1.0 x Tr x 2.752 = =23.75 cf G 966 co
Lip Volume=0.5 x Tr x(2.752—1.752)= 7.07 cf "y2A�CiNE— -'0 .,�
Total Base Volume 30.81 cf N'CLjp \`
Weight of Concrete 4621.69 lb Dl�f/e /ZZfzie
Volume of Displaced Soil 98.13 cf
Soil Volume=Base Vol.+Well Vol.
Volume of Soil above Base Lip 77.72 cf
Soil Lip Volume=5.5 x n x(2.752—1.752)
Weight of Soil above Base Lip . 8937.23 lb
Bouyant Force of Soil Displaced 11284.38 lb
Bouyant Force=Vol. Soil Displaced x Soil Density
Total Weight of Components 13558.91 lb
Safety Factor 1.20
Stability OK!
II "
11-1C:LE
0
n 3.5' DIA.
GRINDER
PUMP TANK
1 — i--IL I
Lk 1
r k.
e 8
l J. d
a
° o `�CONCRETE PER BRUNSWICK
O o� °' v4 COUNTY REQUIREMENTS
FOR ANTI—FLOTATION
{ v d .
•
5.5' I
ATYPICAL RESIDENTIALORINDER PUMP DETAIL,
l
ROY COOPER
Governor
N
,~
MICHAEL S. REGAN
Secretary
WaterRgsources LINDA CULPEPPER
ENVIRONMENTAL QUALITY
Interim Director
May 23, 2018
Ann B. Hardy,County Manager
Brunswick County
P.O. Box 249
Bolivia, NC 28422
Subject: Adjusted Daily Sewage Flow Rate Approval
Brunswick County(WQCS00284)
Dear Ms. Hardy
On February 16, 2018,the Division of Water Resources (Division) initiated a review of the existing
Brunswick County flow reductions to develop a comprehensive flow reduction that would apply to all
permitted but not yet tributary residential connections and all future residential connections within the
Brunswick County service area. In accordance with 15A NCAC 02T.0114(f)(2),the Division has evaluated
the existing flow reductions as granted to various portions of Brunswick County,and based on input
from the Wilmington Regional Office as well as historical data for the county and the Division of Water
Infrastructure(DWI)guidance,the Division hereby approves for use by Brunswick County an adjusted
daily sewage design flow rate with the following conditions:
• The flow reduction is applicable to residential single family dwellings only.
• The minimum flow for 1 and 2 bedroom dwellings shall be 140 gallons per day.
• Each additional bedroom above two bedrooms shall increase the volume by 70 gallons per day
per bedroom (e.g.three bedroom homes shall utilize 210 gallons per day).
• This flow reduction shall not apply to sewer extension applications and/or permits for any other
public or private organizations whose wastewater flows are or might become tributary to
Brunswick County collection system (WQCS00284).
o The flow reduction may be applied to sewer extension applications and/or permits
where the permitted development shall be transferred to Brunswick County upon
completion.
• This flow reduction is only applicable for developments with flows tributary to the current
existing wastewater treatment facilities, and shall supersede any previous flow reductions
granted to developments tributary to the following treatment plants:
o Carolina Shores WWTP(NC0044873)
o Northeast Brunswick Regional WWTP (NC0086819)
o Shallotte WWTF(WQ000798)
o Ocean Isle Beach WWTF (WQ0006085)
--'""Nothing Compares l
State of North Carolina I Environmental Quality I Water Resources
1617 Mail Service Center Raleigh,North Carolina 27699-1617
919-807-6300
.
L
Brunswick County
WQCS00284
o Sea Trail WWTF(WQ0012748)
o West Brunswick Regional WRF(WQ0023693)
• Per 15A NCAC 02T.0114(e)(2), this flow reduction shall not apply to residential property on
barrier islands and similar communities located south or east of the Atlantic Intracoastal
Waterway used as a vacation rental as defined in G.S.42A-4.Such residences shall use 120
gallons per day per habitable room.
• Previous flow reductions as listed in the March 18, 2004 flow reduction approval for 904
Georgetown (185 GPD per 3-bedroom unit) and Bald Head Island (305 GPD per unit)shall
remain in place,as they do not connect to Brunswick County's collection system.
• This flow reduction must be reevaluated and approved by the Division prior to application to
any future Brunswick County treatment facilities.
Future sewer extension applications should be made using the flow reduction amount stated above. All
other aspects of the permitting process remain unchanged, and all applications must comply with the
statues, rules, regulations and minimum design criteria as certified by the owner and engineer.
Regardless of the adjusted design daily wastewater flow rate,at no time shall the wastewater flows
exceed the effluent limits as defined in the permit for the treatment facility or exceed the capacity of
the sewers downstream of any new sewer extension or service connection(s).
The granting of this flow reduction does not prohibit the Division from reopening, revoking, reissuing
and/or modifying the flow reduction as allowed by the laws, rules,and regulations contained in 15A
NCAC 02T, NCGS 143-215.1,or as needed to address changes in State and/or Federal regulations with
respect to wastewater collection systems, protection of surface waters and/or wastewater treatment.
If you have any questions,please contact Christyn Fertenbaugh, P.E.,at(919)807-6312,or via email at
Christyn.Fertenbaugh@ncdenr.gov.
Sincerely,
for Linda Culpepper
Interim Director, Division of Water Resources
by Deborah Gore,Supervisor
Pretreatment, Emergency Response and Collection Systems Branch
Cc: William Pinnix, P.E., Brunswick County( lilliam.Pinnix@brunswickcountync.gov)
John Nichols, P.E., Brunswick County( n.Nichols@brunswickcountync.gov)
Wilmington Regional Office,Water Quality Regional Operations
Central Files- Brunswick County Collection System (WQCS00284)
Central Files—NC0044873, NC0086819,WQ0000798,WQ0006085,WQ0012748, WQ0023693
PERCS(electronic copy)
Page 2 of 2
CRANE BARNES
-i-fir --►-.-
PR wESSURE SYSTEJ
PUMPS& SYSTEMS
Pre-Approval Submittal Overview of Equipment
For
Barnes" ' Grinder Pump Stations
Project: County of Brunswick, North Carolina
Public Utilities Administration
Utilities Operation Center
Attn: Grinder Pump Station Packages
250 Grey Water Road NE
Supply, NC 28462
PH: 910-253-2681
Representative: Pumps, Parts, and Service, Inc.
9325 Forsyth Park Drive
Charlotte, NC 28273
PH: 704-588-6250
FX: 704-588-6258
Attn: Scott Dellinger
Prepared by: Crane Pumps & Systems, Inc.
Attn: Scott Krites, P.S. Applications
PH: 937-773-2772 ext 3044
'.a
3
County of Brunswick, NC
Technical Specifications
for
Grinder Pump Station Packages
REVIEWED
By Scott Krites at 10:32 am, Sep 01, 2010
4
* 'r
Tank
Yes Tank shall be constructed of High Density Polyethylene or Fiberglass Polyester Resew to withstand
normal wool al to I SQ memt oldie maximum external argil and hydrostatic pressure.
WS rank apedpr shalt have imam swap of MID gatlmaa leave lie pump of kf st.
ram. Tank bast shall contain a sufficient(miler to allow for the inquired ame-floatation ballast.This may he
counirunsed no that the Golly can he easily instilled during installation.
"5 Tank lop shall contain an aluminum hatch with r lest door to allow for inspection auJ maraernene.also
the ability to Io_k lop with a standard padlock:fee safety.
>•xr Tank internal dischargepipingshall include Shin-off Valve,Cheek Valve and I I/4^disc laargt pipe.
YE-3
Tank shalt include a crairiless shin 1.wsy float bracket In hang 3 floats and pump power cord and a 2'"
NPT female elect-Sol disehage coupling located at Melon side oftank.
Control Paa ti
nu The control panel shall be a NEMA watertight enclosure with a kluged kiekabk cower.
1E6 roe panel thali have ter 5 amp single pale breakers far separate control and alarm circuits. One two
pole breaker sized to pump full Iced amps ha each pump.
Yea Panel to have a Visual Aram,mounted to the fop of panel,wired to may on until wet well drops below
high knurl Aunt setting An audio alarm externallymounted with a unh-tn-ciieaee banun.
P
Yea Molur xWrter ghafl be designed for continuous operation and equipped with thermal overloads aired fnt
nrrmat current load range. ESS-VIES - O'z1e.taaa Are [corn henna vrrgr t 1113 MC TVR ?PtElf8L' ?Oa .:113
PAVIC S xem14l:3 OOP AM Ors": 3asltci influx.=
xaa Control system design shell be equipped to operate from mils float level sensors.
ras Duplex Panel shall motes!' a manual emergency power transfer switch and generator receptacle An
automatic peogrsmieable phone dialer to include alarm points for high levet.power lost,and canuol
system failure.
Grinder Pump
Yea The grinder pinup stall be denagned to be dtaitabae fcr domed►wastewater service.
YES Pump motor shall ore exceed 2 HP and operate at 230-240 volts t phase.
xis Grinder assembly shall be constructed ref standees steel material and capable of redrrcing an components
in normal domestic sewage.
Yes Ptampncure shall he provided with a mechanical shaft anal to prevent leakage between Lie mrdor and
p^n gip
REVIEWED
By.By Scott Karnes of 10 33 am.Sap 01,2010
A response to the above comments is considered required in order to proceed with the review of the application and
issuance of the permit. If a complete response is not received within 30 days, the application and supporting documents
will be returned to you in accordance with 15A NCAC 02T.0107(e)(2).
Please feel free to provide digital copies of these revised documents and supporting information to me via email along
with hardcopies via mail.
Please let me know if you have any questions. Dale