Loading...
HomeMy WebLinkAboutSW3230608_Supplement-EZ Form_20240223 SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Stoneglen Subdivision 2 Project Area(ac) 12.4 3 Coastal Wetland Area(ac) 0 4 Surface Water Area(ac) 0 5 Is this project High or Low Density? High 6 Does this project use an oft-site SCM? No COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided(feet) _ 30 8 Will the vegetated setback remain vegetated? N/A 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 12 Bioretention Cell 13 Wet Pond 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 1 17 Rainwater Harvesting(RWH) 18 Green Roof 19 Level Spreader-Filter Strip(LS-FS) 20 Disconnected Impervious Surface(DIS) 21 Treatment Swale 22 Dry Pond 23 StormFilter 24 Silva Cell 25 Bayfilter 26 Filterra FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Sean Mayo,PE 28 Organization: Gavel&Dorn Engineering,PLLC 29 Street address: 6730 Freedom Drive 30 City,State,Zip: Charlotte,NC 28214 31 Phone number(s): 7047245047 32 Email: smayo@gaveldorn.com Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. 'Designer _ :a SEAL 7• Sign signer • 036837 'r• • tgbAlk%.;9210 •.A• Ckiih* ZA.3/Z56 #, IA.14 Seal Date DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so, number of drainage areas/SCMs 1 3 Does this project have low density areas? No 4 If so, number of low density drainage areas 0 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 4 Type of SCM Sand Filter 5 Total drainage area (sq ft) 540144 501811 6 Onsite drainage area (sq ft) 540144 501811 7 Offsite drainage area (sq ft) 0 0 8 Total BUA in project (sq ft) 165933 sf 165933 sf New BUA on subdivided lots (subject to permitting) 9 (sq ft) 111600 sf 111600 sf New BUA not on subdivided lots (subject to 10 permitting) (sf) 54333 sf 54333 sf 11 Offsite BUA (sq ft) 12 Breakdown of new BUA not on subdivided lots: - Parking (sq ft) - Sidewalk (sq ft) 6710 sf 6710 sf - Roof (sq ft) - Roadway (sq ft) 47623 sf 47623 sf - Future (sq ft) - Other, please specify in the comment box below (sq ft) New infiltrating permeable pavement on subdivided 13 lots (sq ft) New infiltrating permeable pavement not on 14 subdivided lots (sq ft) Existing BUA that will remain (not subject to 15 permitting) (sq ft) 16 Existing BUA that is already permitted (sq ft) 17 Existing BUA that will be removed (sq ft) 18 Percent BUA 31% 33% 19 Design storm (inches) 1.0 in 1.0 in 20 Design volume of SCM (cu ft) 11785 cf 11785 cf 21 Calculation method for design volume Simple Simple ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): SAND FILTER 1 Drainage area number 1 2 Minimum required treatment volume(cu ft) 10902 sf GENERAL MDC FROM 02H.1050 3 Is the SCM sized to treat the SW from all surfaces at build-out? Yes 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM(H:V)? 3:1 Does the SCM have retaining walls,gabion walls or other 6 engineered side slopes? No 7 Are the inlets,outlets,and receiving stream protected from erosion Yes (10-year storm)? Is there an overflow or bypass for inflow volume in excess of the 8 design volume? Yes 9 What is the method for dewatering the SCM for maintenance? Pump(preferred) 10 If applicable,will the SCM be cleaned out after construction? Yes 11 Does the maintenance access comply with General MDC(8)? Yes 12 Does the drainage easement comply with General MDC(9)? Yes 13 If the SCM is on a single family lot,does(will?)the plat comply with N/A General MDC(10)? 14 Is there an O&M Agreement that complies with General MDC(11)? Yes 15 Is there an O&M Plan that complies with General MDC(12)? Yes 16 Does the SCM follow the device specific MDC? Yes 17 Was the SCM designed by an NC licensed professional? Yes SAND FILTER MDC FROM 02H.1056 18 SHWT elevation(fmsl) 762.8 _ 19 Type of sand filter(open or closed) Open 20 If closed,will the filter will be pre-cast or pour-in-place? 21 If closed,top of grate elevation(fmsl) _ 22 Is this sand filter designed to attenuate peak flows? Yes Sediment Chamber 23 Volume that can be retained in the sediment chamber(cubic feet) 6181 24 Will there be a permanent pool in the sediment chamber? No 25 Bottom of the sediment chamber(fmsl) 26 Area of the sediment chamber(square feet) 2534 sf 27 Physical depth of the sediment chamber(inches) 15 in 28 Ponding depth in the sediment chamber,above any permanent 15 in pool(inches) 29 Elevation of top of weir between chambers((nisi) 769.2 Sand Chamber 30 Volume that can be retained in the sand chamber(cubic feet) 5604 cf 31 Bottom of the sand chamber(fmsl) 767.20 32 Area of the sand chamber(square feet) 3768 sf 33 Physical depth of the sand chamber(inches) 43 in 34 Ponding depth in the sand chamber,above the sand surface 15 in (inches) 35 Elevation of the bypass device(fmsl) 768.45 36 Type of bypass device Weir 37 Mechanism for distributing flow over the sand surface STONE WEIRS 38 Sand specification for sand chamber C33 39 Depth above underdrain pipe(inches) 12 in 40 Will the media be maintained to drain at least two inches per hour at Yes the sand surface? 41 Is at least one clean-out pipe provided at the low point of each Yes underdrain line? 42 Will clean-out pipes be capped? Yes ADDITIONAL INFORMATION 43 Please use this space to provide any additional information about the sand filter(s): Sand Filter 1 4:52 PM 2/23/2024