HomeMy WebLinkAboutSW3230608_Supplement-EZ Form_20240223 SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
PROJECT INFORMATION
1 Project Name Stoneglen Subdivision
2 Project Area(ac) 12.4
3 Coastal Wetland Area(ac) 0
4 Surface Water Area(ac) 0
5 Is this project High or Low Density? High
6 Does this project use an oft-site SCM? No
COMPLIANCE WITH 02H.1003(4)
7 Width of vegetated setbacks provided(feet) _ 30
8 Will the vegetated setback remain vegetated? N/A
9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A
10 Is streambank stabilization proposed on this project? No
NUMBER AND TYPE OF SCMs:
11 Infiltration System
12 Bioretention Cell
13 Wet Pond
14 Stormwater Wetland
15 Permeable Pavement
16 Sand Filter 1
17 Rainwater Harvesting(RWH)
18 Green Roof
19 Level Spreader-Filter Strip(LS-FS)
20 Disconnected Impervious Surface(DIS)
21 Treatment Swale
22 Dry Pond
23 StormFilter
24 Silva Cell
25 Bayfilter
26 Filterra
FORMS LOADED
DESIGNER CERTIFICATION
27 Name and Title: Sean Mayo,PE
28 Organization: Gavel&Dorn Engineering,PLLC
29 Street address: 6730 Freedom Drive
30 City,State,Zip: Charlotte,NC 28214
31 Phone number(s): 7047245047
32 Email: smayo@gaveldorn.com
Certification Statement:
I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the
information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans,
specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here.
'Designer
_ :a SEAL 7• Sign signer
• 036837 'r•
•
tgbAlk%.;9210 •.A• Ckiih* ZA.3/Z56
#, IA.14
Seal Date
DRAINAGE AREAS
1 Is this a high density project? Yes
2 If so, number of drainage areas/SCMs 1
3 Does this project have low density areas? No
4 If so, number of low density drainage areas 0
Is all/part of this project subject to previous rule
5 versions? No
FORMS LOADED
DRAINAGE AREA INFORMATION Entire Site 1
4 Type of SCM Sand Filter
5 Total drainage area (sq ft) 540144 501811
6 Onsite drainage area (sq ft) 540144 501811
7 Offsite drainage area (sq ft) 0 0
8 Total BUA in project (sq ft) 165933 sf 165933 sf
New BUA on subdivided lots (subject to permitting)
9 (sq ft) 111600 sf 111600 sf
New BUA not on subdivided lots (subject to
10 permitting) (sf) 54333 sf 54333 sf
11 Offsite BUA (sq ft)
12 Breakdown of new BUA not on subdivided lots:
- Parking (sq ft)
- Sidewalk (sq ft) 6710 sf 6710 sf
- Roof (sq ft)
- Roadway (sq ft) 47623 sf 47623 sf
- Future (sq ft)
- Other, please specify in the comment box
below (sq ft)
New infiltrating permeable pavement on subdivided
13 lots (sq ft)
New infiltrating permeable pavement not on
14 subdivided lots (sq ft)
Existing BUA that will remain (not subject to
15 permitting) (sq ft)
16 Existing BUA that is already permitted (sq ft)
17 Existing BUA that will be removed (sq ft)
18 Percent BUA 31% 33%
19 Design storm (inches) 1.0 in 1.0 in
20 Design volume of SCM (cu ft) 11785 cf 11785 cf
21 Calculation method for design volume Simple Simple
ADDITIONAL INFORMATION
Please use this space to provide any additional information about the
22 drainage area(s):
SAND FILTER
1 Drainage area number 1
2 Minimum required treatment volume(cu ft) 10902 sf
GENERAL MDC FROM 02H.1050
3 Is the SCM sized to treat the SW from all surfaces at build-out? Yes
4 Is the SCM located away from contaminated soils? Yes
5 What are the side slopes of the SCM(H:V)? 3:1
Does the SCM have retaining walls,gabion walls or other
6 engineered side slopes? No
7 Are the inlets,outlets,and receiving stream protected from erosion Yes
(10-year storm)?
Is there an overflow or bypass for inflow volume in excess of the
8 design volume? Yes
9 What is the method for dewatering the SCM for maintenance? Pump(preferred)
10 If applicable,will the SCM be cleaned out after construction? Yes
11 Does the maintenance access comply with General MDC(8)? Yes
12 Does the drainage easement comply with General MDC(9)? Yes
13 If the SCM is on a single family lot,does(will?)the plat comply with N/A
General MDC(10)?
14 Is there an O&M Agreement that complies with General MDC(11)? Yes
15 Is there an O&M Plan that complies with General MDC(12)? Yes
16 Does the SCM follow the device specific MDC? Yes
17 Was the SCM designed by an NC licensed professional? Yes
SAND FILTER MDC FROM 02H.1056
18 SHWT elevation(fmsl) 762.8 _
19 Type of sand filter(open or closed) Open
20 If closed,will the filter will be pre-cast or pour-in-place?
21 If closed,top of grate elevation(fmsl) _
22 Is this sand filter designed to attenuate peak flows? Yes
Sediment Chamber
23 Volume that can be retained in the sediment chamber(cubic feet) 6181
24 Will there be a permanent pool in the sediment chamber? No
25 Bottom of the sediment chamber(fmsl)
26 Area of the sediment chamber(square feet) 2534 sf
27 Physical depth of the sediment chamber(inches) 15 in
28 Ponding depth in the sediment chamber,above any permanent 15 in
pool(inches)
29 Elevation of top of weir between chambers((nisi) 769.2
Sand Chamber
30 Volume that can be retained in the sand chamber(cubic feet) 5604 cf
31 Bottom of the sand chamber(fmsl) 767.20
32 Area of the sand chamber(square feet) 3768 sf
33 Physical depth of the sand chamber(inches) 43 in
34 Ponding depth in the sand chamber,above the sand surface 15 in
(inches)
35 Elevation of the bypass device(fmsl) 768.45
36 Type of bypass device Weir
37 Mechanism for distributing flow over the sand surface STONE WEIRS
38 Sand specification for sand chamber C33
39 Depth above underdrain pipe(inches) 12 in
40 Will the media be maintained to drain at least two inches per hour at Yes
the sand surface?
41 Is at least one clean-out pipe provided at the low point of each Yes
underdrain line?
42 Will clean-out pipes be capped? Yes
ADDITIONAL INFORMATION
43 Please use this space to provide any additional information about
the sand filter(s):
Sand Filter 1 4:52 PM 2/23/2024