HomeMy WebLinkAboutNC0021920_Compliance Evaluation Inspection_20240214DocuSign Envelope ID: 9742085C-D673-4960-8697-08ADE005E892 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 u 3 I NCO021920 I11 121 24/02/14 I17 18I � I 19 I s I 201 I 211IIIII 111111III II III III1 I I IIIII IIIIIIIII II r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 701LJ � I 71 [n LI 72 I Lni I 71 I 74 79 I I I I I I I80 -1 I I Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES Dermit Number) 09:OOAM 24/02/14 21/02/01 Whiteville WWTP 1000 Nolan Ave Exit Time/Date Permit Expiration Date Whiteville NC 28472 11:20AM 24/02/14 25/08/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Brandon Shaun Rich//910-642-5818 / Nathan Carl Guyton/ORC/910-840-6034/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Brandon S Rich,PO Box 607 Whiteville NC 284720607/Pretreatment Coordinator/910-642-5818/9106423094 Yes Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran 0 Sludge Handling Dispo: Facility Site Review Compliance Schedules Effluent/Receiving Wate 0 Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date DocuSigned by: Idby:DWR/WIRO WQ/910-796-7387/ 2/21/2024 Helen I PerezE iocu n j U 1 D645B4A39694BE... Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date ocuSigned by: 2/21/2024 Tharrington DWR/WIRO WO/ - - /µ F;D0Tom —N4.M4 uti EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. �- 7F141 E73B6F3456V Page# DocuSign Envelope ID: 9742085C-D673-4960-8697-08ADE005E892 NPDES yr/mo/day Inspection Type (Cont.) NCO021920 I11 12I 24/02/14 117 18 i c i Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) A routine compliance inspection of the City of Whiteville Water Reclamation Facility was conducted on February 14, 2024. The purpose of the evaluation was to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES Permit NC0021920. Brandon Rich, operator and Pretreatment Coordinator, was present during the inspection. This 3 MG treatment plant is a Biological Nutrient Removal (BNR) oxidation ditch system that discharges to the White Marsh, a class C-Swamp water in the Lumber River Basin. Currently, the flow averages approximately 1.4 MG. The faility appears to be well maintained and operated. All records were readily available for review. An inspection of the laboratory was completed recently by the Division's Laboratory Certification staff. A review of records of the past 5 years show no effluent limit violations and a Notice of Deficiency issued for the 2/18/2020 inspection. The facility is compliant with NPDES Permit NC0021920. Please review the comment sections of the inspection report for more details. Page# DocuSign Envelope ID: 9742085C-D673-4960-8697-08ADE005E892 Permit: NCO021920 Owner -Facility: Whiteville WWTP Inspection Date: 02/14/2024 Inspection Type: Compliance Evaluation Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: The current permit expires on 08/31/2025. Compliance Schedules Is there a compliance schedule for this facility? Is the facility compliant with the permit and conditions for the review period? Comment: No comment. Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Yes No NA NE ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ Yes No NA NE ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ El EJ El ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ Page# 3 DocuSign Envelope ID: 9742085C-D673-4960-8697-08ADE005E892 Permit: NCO021920 Owner -Facility: Whiteville WWTP Inspection Date: 02/14/2024 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Facility has copy of previous year's Annual Report on file for review? 0 ❑ ❑ ❑ Comment: Daily operation and maintenance is documented on weekly check sheets and later entered on a main sDeadsheet. Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? ■ ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? ■ ❑ ❑ ❑ # Is the facility using a contract lab? 0 ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 ❑ ❑ ❑ ■ degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ■ ❑ ❑ ❑ Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ■ ❑ ❑ ❑ Comment: The facility is lab certified, Certification #161, and analyzes all the field parameters, BOD, TSS and Fecal Coliform. The remaining parameters are tested by the contract lab, Waypoint Analytical, Certification #3. Calibration logs, Bench sheets and temperature lops appear to be complete. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: No comment. Bar Screens Type of bar screen Yes No NA NE a.Manual ❑ b.Mechanical Are the bars adequately screening debris? 0 ❑ ❑ ❑ Is the screen free of excessive debris? 0 ❑ ❑ ❑ Is disposal of screening in compliance? 0 ❑ ❑ ❑ Is the unit in good condition? ❑ N ❑ ❑ Comment: Currently, the mechanical bar screen is not in operation and is being repaired. Influent is flowing through the manual barscreen until repairs are complete. Grit Removal Type of grit removal Yes No NA NE Page# 4 DocuSign Envelope ID: 9742085C-D673-4960-8697-08ADE005E892 Permit: NCO021920 Owner -Facility: Whiteville WWTP Inspection Date: 02/14/2024 Inspection Type: Compliance Evaluation Grit Removal a.Manual b.Mechanical Is the grit free of excessive organic matter? Is the grit free of excessive odor? # Is disposal of grit in compliance? Comment: No comment. Flow Measurement - Influent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE ❑ ■ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ■ ❑ Comment: The influent flow meter was calibrated on 5-2-2023 by Carolina Technical Services. Influent Sampling # Is composite sampling flow proportional? Is sample collected above side streams? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is sampling performed according to the permit? Comment: The influent sampler cabinet was 6 degrees Celcius during the inspection. Pump Station - Influent Is the pump wet well free of bypass lines or structures? Is the wet well free of excessive grease? Are all pumps present? Are all pumps operable? Are float controls operable? Is SCADA telemetry available and operational? Is audible and visual alarm available and operational? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ ■ • ❑ ❑ ❑ • ❑ ❑ ❑ ■ ❑ ❑ ❑ Yes No NA NE ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ ■ ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ Comment: The SCADA system alerts operators of any alarms at the plant through their cell phones. Page# 5 DocuSign Envelope ID: 9742085C-D673-4960-8697-08ADE005E892 Permit: NCO021920 Owner -Facility: Whiteville WWTP Inspection Date: 02/14/2024 Inspection Type: Compliance Evaluation Pump Station - Influent Oxidation Ditches Are the aerators operational? Are the aerators free of excessive solids build up? # Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin's surface? Is the DO level acceptable? Are settleometer results acceptable (> 30 minutes)? Is the DO level acceptable?(1.0 to 3.0 mg/1) Are settelometer results acceptable?(400 to 800 ml/I in 30 minutes) Yes No NA NE Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ Comment: The dual oxidation ditch system is designed as a BNR treatment system with anaerobic and anoxic zones located at the front end of the ditches. Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ Comment: From the oxidation ditches, watewater flows through a distribution box, splitting flow into the 3 secondary clarifiers. Pumps-RAS-WAS Yes No NA NE Are pumps in place? 0 ❑ ❑ ❑ Are pumps operational? 0 ❑ ❑ ❑ Are there adequate spare parts and supplies on site? ❑ ❑ ❑ ■ Comment: No comment. Page# 6 DocuSign Envelope ID: 9742085C-D673-4960-8697-08ADE005E892 Permit: NC0021920 Inspection Date: 02/14/2024 Filtration (High Rate Tertiary) Type of operation: Is the filter media present? Owner -Facility: Whiteville WWTP Inspection Type: Compliance Evaluation Is the filter surface free of clogging? Is the filter free of growth? Is the air scour operational? Is the scouring acceptable? Is the clear well free of excessive solids and filter media? Yes No NA NE Cross flow ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Comment: The dual cloth disc filters automatically backwash when the drums start to rotate. Disinfection -Liquid Yes No NA NE Is there adequate reserve supply of disinfectant? ■ ❑ ❑ ❑ (Sodium Hypochlorite) Is pump feed system operational? 0 ❑ ❑ ❑ Is bulk storage tank containment area adequate? (free of leaks/open drains) 0 ❑ ❑ ❑ Is the level of chlorine residual acceptable? ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? ■ ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? ❑ ❑ ❑ Comment: No comment. De -chlorination Yes No NA NE Type of system ? Liquid Is the feed ratio proportional to chlorine amount (1 to 1)? ❑ ❑ ❑ Is storage appropriate for cylinders? 0 ❑ ❑ ❑ # Is de -chlorination substance stored away from chlorine containers? 0 ❑ ❑ ❑ Comment: Are the tablets the proper size and type? ❑ ❑ 0 ❑ Are tablet de -chlorinators operational? ❑ ❑ 0 ❑ Number of tubes in use? Comment: No comment. Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? 0 ❑ ❑ ❑ Is the flow meter operational? M ❑ ❑ ❑ Page# 7 DocuSign Envelope ID: 9742085C-D673-4960-8697-08ADE005E892 Permit: NCO021920 Owner -Facility: Whiteville WWTP Inspection Date: 02/14/2024 Inspection Type: Compliance Evaluation Flow Measurement - Effluent Yes No NA NE (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ ❑ Comment: The effluent flow meter was calibrated on 5-2-2023 by Carolina Technical Services. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? 0 ❑ ❑ ❑ Is sample collected below all treatment units? 0 ❑ ❑ ❑ Is proper volume collected? ❑ ❑ ❑ ■ Is the tubing clean? 0 ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 ■ ❑ ❑ ❑ degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type ■ ❑ ❑ ❑ representative)? Comment: The composite sampler cabinet was 0.5 degrees Celsius during the inspection. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? ■ ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: No comment. Upstream / Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, 0 ❑ ❑ ❑ and sampling location)? Comment: Upstream sampling location is at the bridge on US 74/76 and downstream sampling location is at the railroad crossing. Aerobic Digester Is the capacity adequate? Is the mixing adequate? Is the site free of excessive foaming in the tank? # Is the odor acceptable? # Is tankage available for properly waste sludge? Yes No NA NE ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: The digested sludge is stored in a 0.88 MG sludge holding tank. Solids are removed every 2-3 years by Synagro for land application. Page# 8 DocuSign Envelope ID: 9742085C-D673-4960-8697-08ADE005E892 Permit: NC0021920 Owner -Facility: Whiteville WWTP Inspection Date: 02/14/2024 Inspection Type: Compliance Evaluation Standby Power Is automatically activated standby power available? Is the generator tested by interrupting primary power source? Is the generator tested under load? Was generator tested & operational during the inspection? Do the generator(s) have adequate capacity to operate the entire wastewater site? Is there an emergency agreement with a fuel vendor for extended run on back-up power? Is the generator fuel level monitored? Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ Comment: The generator is automatically tested daily and under load a few times a year. Page# 9