HomeMy WebLinkAboutNCG550336_Lab Analysis Data_20240221#=CL#
February 13, 2024
LIMS USE: FR - ONE CLIENT
LIMS OBJECT ID: 92711767
92711767
Project:
Pace Project No.:
RE:
One Time Client
Private Small Jobs
Huntersville, NC 28078
STUART SAMPLING EVENT
Dear One Client:
Enclosed are the analytical results for sample(s) received by the laboratory on February 06, 2024. The results relate only
to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the
laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report.
The test results provided in this final report were generated by each of the following laboratories within the Pace Network:
• Pace Analytical Services - Asheville
• Pace Analytical Services - Charlotte
• Pace Analytical Services - Ormond Beach
If you have any questions concerning this report, please feel free to contact me.
Sincerely,
Ashari Taylor-Watson
ashari.taylor-watson@pacelabs.com
Project Manager
704-977-0939
Enclosures
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, LLC.
Pace Analytical Services, LLC
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 1 of 11
#=CP#
CERTIFICATIONS
Pace Project No.:
Project:
92711767
STUART SAMPLING EVENT
Pace Analytical Services Ormond Beach
8 East Tower Circle, Ormond Beach, FL 32174
Alaska DEC- CS/UST/LUST
Alabama Certification #: 41320
California Certification# 3096
Colorado Certification: FL NELAC Reciprocity
Connecticut Certification #: PH-0216
Delaware Certification: FL NELAC Reciprocity
DoD-ANAB #:ADE-3199
Florida Certification #: E83079
Georgia Certification #: 955
Guam Certification: FL NELAC Reciprocity
Hawaii Certification: FL NELAC Reciprocity
Illinois Certification #: 200068
Indiana Certification: FL NELAC Reciprocity
Kansas Certification #: E-10383
Kentucky Certification #: 90050
Louisiana Certification #: FL NELAC Reciprocity
Louisiana Environmental Certificate #: 05007
Maine Certification #: FL01264
Maryland Certification: #346
Massachusetts Certification #: M-FL1264
Michigan Certification #: 9911
Mississippi Certification: FL NELAC Reciprocity
Missouri Certification #: 236
Montana Certification #: Cert 0074
Nebraska Certification: NE-OS-28-14
New Hampshire Certification #: 2958
New Jersey Certification #: FL022
New York Certification #: 11608
North Carolina Environmental Certificate #: 667
North Carolina Certification #: 12710
North Dakota Certification #: R-216
Ohio DEP 87780
Oklahoma Certification #: D9947
Pennsylvania Certification #: 68-00547
Puerto Rico Certification #: FL01264
South Carolina Certification: #96042001
Tennessee Certification #: TN02974
Texas Certification: FL NELAC Reciprocity
US Virgin Islands Certification: FL NELAC Reciprocity
Virginia Environmental Certification #: 460165
West Virginia Certification #: 9962C
Wisconsin Certification #: 399079670
Wyoming (EPA Region 8): FL NELAC Reciprocity
Pace Analytical Services Charlotte
South Carolina Laboratory ID: 99006
9800 Kincey Ave. Ste 100, Huntersville, NC 28078
North Carolina Drinking Water Certification #: 37706
North Carolina Field Services Certification #: 5342
North Carolina Wastewater Certification #: 12
South Carolina Laboratory ID: 99006
South Carolina Certification #: 99006001
South Carolina Drinking Water Cert. #: 99006003
Florida/NELAP Certification #: E87627
Kentucky UST Certification #: 84
Louisiana DoH Drinking Water #: LA029
Virginia/VELAP Certification #: 460221
Pace Analytical Services Asheville
2225 Riverside Drive, Asheville, NC 28804
Florida/NELAP Certification #: E87648
North Carolina Drinking Water Certification #: 37712
North Carolina Wastewater Certification #: 40
South Carolina Laboratory ID: 99030
South Carolina Certification #: 99030001
Virginia/VELAP Certification #: 460222
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, LLC.
Pace Analytical Services, LLC
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 2 of 11
#=SA#
SAMPLE ANALYTE COUNT
Pace Project No.:
Project:
92711767
STUART SAMPLING EVENT
Lab ID Sample ID Method
Analytes
Reported LaboratoryAnalysts
92711767001 001 EPA 200.8 1 PASI-OBSL
Colisure 2 PASI-CKDF
EPA 353.2 Rev 2.0 1993 2 PASI-ANCF
PASI-A = Pace Analytical Services - Asheville
PASI-C = Pace Analytical Services - Charlotte
PASI-O = Pace Analytical Services - Ormond Beach
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, LLC.
Pace Analytical Services, LLC
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 3 of 11
#=AR#
ANALYTICAL RESULTS
Pace Project No.:
Project:
92711767
STUART SAMPLING EVENT
Sample:001 Lab ID:92711767001 Collected:02/05/24 11:25 Received:02/06/24 09:50 Matrix:Drinking Water
Parameters Results Units DF Prepared Analyzed CAS No.QualReport Limit
Analytical Method: EPA 200.8
Pace Analytical Services - Ormond Beach
200.8 MET ICPMS Drinking Water
Lead ND ug/L 02/13/24 11:54 7439-92-11.0 1
Analytical Method: Colisure Preparation Method: Colisure
Pace Analytical Services - Charlotte
Total Coliform (P/A) CHT
Total Coliforms PRESENT 02/07/24 17:3102/06/24 17:141
E.coli ABSENT 02/07/24 17:3102/06/24 17:141
Analytical Method: EPA 353.2 Rev 2.0 1993
Pace Analytical Services - Asheville
353.2 Nitrogen, NO2/NO3 DW
Nitrogen, Nitrate 3.5 mg/L 02/07/24 01:04 14797-55-80.040 1
Nitrogen, Nitrite ND mg/L 02/07/24 01:04 14797-65-00.040 1
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, LLC.Date: 02/13/2024 05:35 PM
Pace Analytical Services, LLC
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 4 of 11
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92711767
STUART SAMPLING EVENT
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
988711
EPA 200.8
EPA 200.8
200.8 MET No Prep Drinking Water
Laboratory:Pace Analytical Services - Ormond Beach
Associated Lab Samples:92711767001
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:5436357
Associated Lab Samples:92711767001
Matrix:Water
Analyzed
Lead ug/L ND 1.0 02/13/24 12:00
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
5436358LABORATORY CONTROL SAMPLE:
LCSSpike
Lead ug/L 46.550 93 85-115
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
5436353MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
35857432001
5436354
MSD
Result
MSD
% Rec RPD
MSDMS
Spike
Conc.
Lead ug/L 50 92 70-13093 1500.00025
U mg/L
46.1 46.5
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
5436355MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
60446497001
5436356
MSD
Result
MSD
% Rec RPD
MSDMS
Spike
Conc.
Lead ug/L 50 92 70-13092 1502.3 48.5 48.1
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, LLC.Date: 02/13/2024 05:35 PM
Pace Analytical Services, LLC
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 5 of 11
#=QC#
QUALITY CONTROL DATA
Pace Project No.:
Project:
92711767
STUART SAMPLING EVENT
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
QC Batch:
QC Batch Method:
Analysis Method:
Analysis Description:
830490
EPA 353.2 Rev 2.0 1993
EPA 353.2 Rev 2.0 1993
353.2 Nitrogen, NO2/NO3 DW
Laboratory:Pace Analytical Services - Asheville
Associated Lab Samples:92711767001
Parameter Units
Blank
Result
Reporting
Limit Qualifiers
METHOD BLANK:4292521
Associated Lab Samples:92711767001
Matrix:Water
Analyzed
Nitrogen, Nitrate mg/L ND 0.040 02/07/24 01:02
Nitrogen, Nitrite mg/L ND 0.040 02/07/24 01:02
Parameter Units
LCS
Result
% Rec
Limits Qualifiers% RecConc.
4292522LABORATORY CONTROL SAMPLE:
LCSSpike
Nitrogen, Nitrate mg/L 1.51.5 102 90-110
Nitrogen, Nitrite mg/L 1.01 104 90-110
Parameter Units
MS
Result
% Rec
Limits Qual% RecConc.
4292523MATRIX SPIKE & MATRIX SPIKE DUPLICATE:
MSSpike
Result
92711767001
4292524
MSD
Result
MSD
% Rec RPD
MSDMS
Spike
Conc.
Nitrogen, Nitrate mg/L 1.5 110 90-11094 51.53.5 5.1 4.9
Nitrogen, Nitrite mg/L 1 103 90-110104 11ND1.0 1.0
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, LLC.Date: 02/13/2024 05:35 PM
Pace Analytical Services, LLC
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 6 of 11
#=QL#
QUALIFIERS
Pace Project No.:
Project:
92711767
STUART SAMPLING EVENT
DEFINITIONS
DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot.
ND - Not Detected at or above adjusted reporting limit.
TNTC - Too Numerous To Count
J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit.
MDL - Adjusted Method Detection Limit.
PQL - Practical Quantitation Limit.
RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and
bias for a specific analyte in a specific matrix.
S - Surrogate
1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is
a combined concentration.
Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values.
LCS(D) - Laboratory Control Sample (Duplicate)
MS(D) - Matrix Spike (Duplicate)
DUP - Sample Duplicate
RPD - Relative Percent Difference
NC - Not Calculable.
SG - Silica Gel - Clean-Up
U - Indicates the compound was analyzed for, but not detected.
Acid preservation may not be appropriate for 2 Chloroethylvinyl ether.
A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA
Method 8260.
N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for
each analyte is a combined concentration.
Reported results are not rounded until the final step prior to reporting. Therefore, calculated parameters that are typically reported as
"Total" may vary slightly from the sum of the reported component parameters.
Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes.
TNI - The NELAC Institute.
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, LLC.Date: 02/13/2024 05:35 PM
Pace Analytical Services, LLC
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 7 of 11
#=CR#
QUALITY CONTROL DATA CROSS REFERENCE TABLE
Pace Project No.:
Project:
92711767
STUART SAMPLING EVENT
Lab ID Sample ID QC Batch Method QC Batch Analytical Method
Analytical
Batch
92711767001 988711001EPA 200.8
92711767001 830784 830785001ColisureColisure
92711767001 830490001EPA 353.2 Rev 2.0 1993
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, LLC.Date: 02/13/2024 05:35 PM
Pace Analytical Services, LLC
9800 Kincey Ave. Suite 100
Huntersville, NC 28078
(704)875-9092
Page 8 of 11
Page 9 of 11
Page 10 of 11
Page 11 of 11