HomeMy WebLinkAboutSW6231104_Supplement-EZ Form_20240221 SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
PROJECT INFORMATION
1 ProJect Name Tractor Supply Store-West End
2 Project Area(ac) ----. '64e.to■tl1
3 Coastal Wetland Area ac _ 0
4 Surface Water Area(ac) - — - 0
5 Is this project High or Low Density? _ High _6 Does this project use an off-site SCM? I no
(COMPLIANCE WITH 02H.1003(4)
7 Width of vegetated setbacks provided(feet) 30-ft
' 8 Will the vegetated setback remain vegetated? Yes 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A
10 Is streambank stabilization proposed on this project? No
NUMBER AND TYPE OF SCMs:
1--
11 Infiltration System 1
12 Bioretention Cell
13 iWet Pond
14 Stormwater Wetland
15 Permeable Pavement
16 Sand Filter
17 Rainwater Harvesting(RWH)
18 Green Roof
19 Level Spreader-Filter Strip(LS-FS) — -
20 Disconnected Impervious Surface(DIS) -
21 ,Treatment Swale 22 Dry Pond —_ „_-
23 StormFilter
24 Silva Cell 25 Bayfilter
26 Filterra
FORMS LOADED
DESIGNER CERTIFICATION
r
27 Name and Title: i J. Branch Smith,PE
28 Organization: 1 Paramounte En ineerin Inc.
29 Street address: 122 Cinema Drive
30 City,State,Zip_ _ Wilmington,NC 28409
31 Phone number(s):Email:
910-791-6707
32 , _ bsmith@paramounte-eng.com
Certification Statement:
I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision:that the
information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans,
specifications,operation and maintenance agreements and other supporting information are consistent with the Information provided here.
Designer
0011111//,
O 4SSj••../4/ ,, n2�
.'0 Oti'.. % Signa re of Designer
:CL SEAL _
— 034354 .
/ LS//°RANCN�\\ / /q/2�
/r i'JW 1\\ E ate
DRAINAGE AREAS
1 Is this a high density project? Yes
2 If so, number of drainage areas/SCMs 1
3 Does this project have low density areas? No
4 If so, number of low density drainage areas 0
Is all/part of this project subject to previous rule
5 versions? No
FORMS LOADED
DRAINAGE AREA INFORMATION Entire Site 1
4 Type of SCM PROJECT AREA Infiltration Basin
5 Total drainage area (sq ft) 267458 221500
6 Onsite drainage area (sq ft) 267458 221500
7 Offsite drainage area (sq ft) 0 0
8 Total BUA in project(sq ft) 139300 sf 139300 sf
New BUA on subdivided lots (subject to permitting)
9 (sq ft) .0 sf .0 sf
New BUA not on subdivided lots (subject to
10 permitting) (sf) 139300 sf 139300 sf
11 Offsite BUA (sq ft) .0 sf .0 sf
12 Breakdown of new BUA not on subdivided lots:
- Parking (sq ft) 84100 sf 84100 sf
-Sidewalk (sq ft) 28000 sf 28000 sf
- Roof(sq ft) 22200 sf 22200 sf
- Roadway(sq ft)
- Future(sq ft) 5000 sf 5000 sf
- Other, please specify in the comment box below
(sq ft) .0 sf .0 sf
New infiltrating permeable pavement on subdivided
13 lots (sq ft) -New infiltrating permeable pavement not on
14 subdivided lots(sq ft) - -
Existing BUA that will remain (not subject to
15 permitting) (sq ft) - -
16 Existing BUA that is already permitted (sq ft) - -
17 Existing BUA that will be removed (sq ft) 2000 sf 2000 sf
18 Percent BUA 52.10% 62.90%
19 Design storm (inches) 1.50 in
20 Design volume of SCM (cu ft) 17056 cf
21 Calculation method for design volume Simple
ADDITIONAL INFORMATION
Please use this space to provide any additional information about the
22 drainage area(s):
INFILTRATION SYSTEM
Drainage1 area number 2 ,.
2 Minimum required treatment volume(cu ft) 1
GENERAL MDC f ROM 0211.1050 3 —
Is the SCM sized to treat the SW from all surfaces at build-out? Yes
4 Is the SCM located away from contaminated soils? Yes
5 What are the side slopes of the SCM(H:V or enter"Vertical"for
trenches)? 4:1
6 Does the SCM have retaining walls,gabion walls or other
engineered side slopes? No
7 Are the inlets.outlets,and receiving stream protected from erosion
(10-year storm)? Yes
8 Is there an overflow or bypass for inflow volume in excess of the
design volume? Yes
9 What is the method for dewatering the SCM for maintenance? Pump(preferred)
10 If applicable,will the SCM be cleaned out after construction? Yes
11 Does the maintenance access comply with General MDC(8)? Yes
12 Does the drainage easement comply with General MDC(9)? Yes
13 If the SCM is on a single family lot,does(will?)the plat comply with N/A
General MDC(10)?
14 Is there an O&M Agreement that complies with General MDC(11)? Yes
15 Is there an O&M Plan that complies with General MDC(12)? Yes
16 Does the SCM follow the device specific MDC? Yes
17 Was the SCM designed by an NC licensed professional? Yes
INFILTRATION SYSTEM MDraom 03N.1Q55
18 Proposed slope of the subgrade surface(%) 0%
19 Are terraces or baffles provided? No
20 j Type of pretreatment: Other
Salk Data
21 Was the soil investigated in the footprint and at the elevation of the
infiltration system? Yes
22 SHWT elevation(fmsl) _ 577.50
23 Depth to SHWT per soils report(in) 240.00
24 Ground elevation at boring in soils report(fmsl) 597.50
25 Is a detailed hydrogeologic study attached if the separation is
between 1 and 2 feet? N/A
26 Soil infiltration rate(in/hr) 3.37
27 Factor of safety(FS) (2 is recommended): 2.00
Elevations
29 Bottom elevation(find) 585.00 ft
30 Storage elevation(fmsl) 588.3 ft
31 Bypass elevation(fmsl) 594.00 ft
For Basins Only
32 Bottom surface area(ft2) 2850 ft
33 Storage elevation surface area(ft2) 7400.ft
For Trenches Only
34 Length(ft) na
35 Width(ft)
36 Perforated pipe diameter,if applicable(inches)
37 Number of laterals
38 Total length of perforated piping
39 Stone type,if applicable
40 Stone porosity(%)
41 Is stone free of fines?
42 Is the stone wrapped in geotextile fabric? _
43 Has at least one inspection port been provided?
VolumeslDrawdown
44 Design volume of SCM(cu ft) 17056 cf 1
45 Time to draw down(hours) 43 Itrs
ADDITIONAL INFORMATION
Please use this space to provide any additional information about
46
the infiltration systems)._ __—
Line 20 Pretreatment is 12"sumps in each storm basin. See plans and details.
Infiltration 1