HomeMy WebLinkAboutNC0085359_Compliance Evaluation Inspection_20240105 (2)United States Environmental Protection Agency
Form Approved.
EPA Washington, D.C. 20460
OMB No. 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN 1 2 u 3 I NC0085359 111 121 23/12/19 I17 18 LC] I 19 I s I 20L]
21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6
Inspection
Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved -------------------
67
I 72 I n, I 71 I 74 79 I I I I I I I80
701� I 711 L
LJ L -1 I I
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES permit Number)
10:OOAM 23/12/19
21/07/01
Twelve Mile Creek WWTP
8299 Kensington Dr
Exit Time/Date
Permit Expiration Date
Waxhaw NC 28173
12:15PM 23/12/19
25/12/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
Keith Allen Purgason/ORC/704-542-0736/
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Brian Matthews,500 N Main St Ste 70 Monroe NC 28112/Interim County
Manager/704-383-3636/ No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit 0 Flow Measurement Operations & Maintenar Records/Reports
Self -Monitoring Progran 0 Sludge Handling Dispo: Facility Site Review Effluent/Receiving Wate
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signatur ems) Agency/Office/Phone and Fax Numbers Date
1/5/2024
Roberto Scheller DWR/MRO WQ/707-235-2204/
91C2A007838943E...
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
Brandy Costner DWR/MRO WO/704-235-2185/ DocuSigned by: 1/5/2024 Lw*—
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. �-27DFMCF858043F...
Page#
NPDES yr/mo/day Inspection Type
NCO085359 I11 12I 23/12/19 117 18 ici cJ
(Cont.)
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
The subject facility is permitted to dischaarge 7.5 MGD of treated wastewater, via Outfall #001, into
Twelve Mile Creek, Classified as C Waters in the Catawba River Basin. The current permit became
effective on July 1, 2021 and expires on December 31, 2025.
A 12-month compliance history was review from November 2022 through October 2023. Two
violations for CBOD were reported, one on 03-2023 for a Monthly Average Limit violation (Reported
5.47 mg/1) and one Weekly Average violation on 04-2023 (Reported 9.04 mg/1).
Wastewater Performance Report for fisical year 2022-2023 was reviewed on Union County web site.
12-Month average flow for calendar year 2022 was caculated at 5.753 MGD or 76.7% of permitted
flow.
Page#
Permit: NCO085359 Owner -Facility: Twelve Mile Creek WWTP
Inspection Date: 12/19/2023 Inspection Type: Compliance Evaluation
Permit
Yes
No
NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
❑
❑
■
❑
application?
Is the facility as described in the permit?
■
❑
❑
❑
# Are there any special conditions for the permit?
■
❑
❑
❑
Is access to the plant site restricted to the general public?
■
❑
❑
❑
Is the inspector granted access to all areas for inspection?
■
❑
❑
❑
Comment:
Record Keeping
Yes
No
NA
NE
Are records kept and maintained as required by the permit?
■
❑
❑
❑
Is all required information readily available, complete and current?
■
❑
❑
❑
Are all records maintained for 3 years (lab. reg. required 5 years)?
■
❑
❑
❑
Are analytical results consistent with data reported on DMRs?
■
❑
❑
❑
Is the chain -of -custody complete?
■
❑
❑
❑
Dates, times and location of sampling
■
Name of individual performing the sampling
■
Results of analysis and calibration
■
Dates of analysis
■
Name of person performing analyses
■
Transported COCs
■
Are DMRs complete: do they include all permit parameters?
■
❑
❑
❑
Has the facility submitted its annual compliance report to users and DWQ?
■
❑
❑
❑
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified
■
❑
❑
❑
operator on each shift?
Is the ORC visitation log available and current?
■
❑
❑
❑
Is the ORC certified at grade equal to or higher than the facility classification?
■
❑
❑
❑
Is the backup operator certified at one grade less or greater than the facility
■
❑
❑
❑
classification?
Is a copy of the current NPDES permit available on site?
■
❑
❑
❑
Facility has copy of previous year's Annual Report on file for review?
❑
❑
❑
■
Comment:
Bar Screens Yes No NA NE
Type of bar screen
Page# 3
Permit: NC0085359
Inspection Date: 12/19/2023
Bar Screens
a.Manual
b.Mechanical
Are the bars adequately screening debris?
Is the screen free of excessive debris?
Is disposal of screening in compliance?
Is the unit in good condition?
Comment:
Pump Station - Influent
Is the pump wet well free of bypass lines or structures?
Is the wet well free of excessive grease?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Is SCADA telemetry available and operational?
Is audible and visual alarm available and operational?
Comment:
Chemical Feed
Is containment adequate?
Is storage adequate?
Are backup pumps available?
Is the site free of excessive leaking?
Comment: Alkalinity added at influent pump station.
Grit Removal
Type of grit removal
a.Manual
b.Mechanical
Is the grit free of excessive organic matter?
Is the grit free of excessive odor?
# Is disposal of grit in compliance?
Owner -Facility: Twelve Mile Creek WWTP
Inspection Type: Compliance Evaluation
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Yes No NA NE
■ ❑ ❑ ❑
❑ ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
■ ❑ ❑ ❑
❑ ❑ ❑ ■
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Yes No NA NE
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
Page# 4
Permit: NCO085359 Owner -Facility: Twelve Mile Creek WWTP
Inspection Date: 12/19/2023 Inspection Type: Compliance Evaluation
Grit Removal Yes No NA NE
Comment:
Flow Measurement - Influent
Yes
No
NA
NE
# Is flow meter used for reporting?
0
❑
❑
❑
Is flow meter calibrated annually?
0
❑
❑
❑
Is the flow meter operational?
0
❑
❑
❑
(If units are separated) Does the chart recorder match the flow meter?
0
❑
❑
❑
Comment:
Influent Sampling
Yes
No
NA
NE
# Is composite sampling flow proportional?
0
❑
❑
❑
Is sample collected above side streams?
■
❑
❑
❑
Is proper volume collected?
0
❑
❑
❑
Is the tubing clean?
S
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
■
❑
❑
❑
degrees Celsius)?
Is sampling performed according to the permit?
❑
❑
❑
Comment:
Nutrient Removal
Yes
No
NA
NE
# Is total nitrogen removal required?
■
❑
❑
❑
# Is total phosphorous removal required?
0
❑
❑
❑
Type
Biological
# Is chemical feed required to sustain process?
0
❑
❑
❑
Is nutrient removal process operating properly?
■
❑
❑
❑
Comment:
Aeration Basins
Yes No
NA NE
Mode of operation
Ext. Air
Type of aeration system
Diffused
Is the basin free of dead spots?
0 ❑
❑ ❑
Are surface aerators and mixers operational?
❑ ❑
0 ❑
Are the diffusers operational?
■ ❑
❑ ❑
Page# 5
Permit: NCO085359 Owner -Facility:
Inspection Date: 12/19/2023 Inspection Type:
Twelve Mile Creek WWTP
Compliance Evaluation
Aeration Basins
Yes
No
NA
NE
Is the foam the proper color for the treatment process?
0
❑
❑
❑
Does the foam cover less than 25% of the basin's surface?
0
❑
❑
❑
Is the DO level acceptable?
0
❑
❑
❑
Is the DO level acceptable?(1.0 to 3.0 mg/I)
0
❑
❑
❑
Comment:
Secondary Clarifier
Yes
No
NA
NE
Is the clarifier free of black and odorous wastewater?
0
❑
❑
❑
Is the site free of excessive buildup of solids in center well of circular clarifier?
0
❑
❑
❑
Are weirs level?
0
❑
❑
❑
Is the site free of weir blockage?
■
❑
❑
❑
Is the site free of evidence of short-circuiting?
0
❑
❑
❑
Is scum removal adequate?
0
❑
❑
❑
Is the site free of excessive floating sludge?
0
❑
❑
❑
Is the drive unit operational?
0
❑
❑
❑
Is the return rate acceptable (low turbulence)?
0
❑
❑
❑
Is the overflow clear of excessive solids/pin floc?
0
❑
❑
❑
Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth)
❑
❑
❑
Comment:
Pumps-RAS-WAS
Yes
No
NA
NE
Are pumps in place?
❑
❑
❑
❑
Are pumps operational?
❑
❑
❑
❑
Are there adequate spare parts and supplies on site?
❑
❑
❑
❑
Comment:
Filtration (High Rate Tertiary)
Yes
No
NA NE
Type of operation:
Is the filter media present?
❑
❑
❑
❑
Is the filter surface free of clogging?
❑
❑
❑
❑
Is the filter free of growth?
❑
❑
❑
❑
Is the air scour operational?
❑
❑
❑
❑
Is the scouring acceptable?
❑
❑
❑
❑
Page# 6
Permit: NCO085359 Owner -Facility: Twelve Mile Creek WWTP
Inspection Date: 12/19/2023 Inspection Type: Compliance Evaluation
Filtration (High Rate Tertiary) Yes No NA NE
Is the clear well free of excessive solids and filter media? ❑ ❑ ❑ ❑
Comment:
Disinfection - UV
Yes
No
NA
NE
Are extra UV bulbs available on site?
❑
❑
❑
■
Are UV bulbs clean?
■
❑
❑
❑
Is UV intensity adequate?
■
❑
❑
❑
Is transmittance at or above designed level?
■
❑
❑
❑
Is there a backup system on site?
■
❑
❑
❑
Is effluent clear and free of solids?
■
❑
❑
❑
Comment:
Effluent Sampling
Yes
No
NA
NE
Is composite sampling flow proportional?
■
❑
❑
❑
Is sample collected below all treatment units?
■
❑
❑
❑
Is proper volume collected?
■
❑
❑
❑
Is the tubing clean?
■
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0
■
❑
❑
❑
degrees Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
■
❑
❑
❑
representative)?
Comment:
Aerobic Digester
Yes
No
NA
NE
Is the capacity adequate?
■
❑
❑
❑
Is the mixing adequate?
■
❑
❑
❑
Is the site free of excessive foaming in the tank?
❑
❑
❑
■
# Is the odor acceptable?
■
❑
❑
❑
# Is tankage available for properly waste sludge?
■
❑
❑
❑
Comment:
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? ■ ❑ ❑ ❑
Page# 7
Permit: NCO085359
Inspection Date: 12/19/2023
Operations & Maintenance
Owner -Facility: Twelve Mile Creek WWTP
Inspection Type: Compliance Evaluation
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Yes No NA NE
■ ❑ ❑ ❑
Page#