Loading...
HomeMy WebLinkAboutNC0023884_Pretreatment_Annual_Report_202402194C Sa/isbary-R�wa� PRETREATMENT ANNUAL REPORT February 9, 2024 Period covered by this report: January 1, 2023 to June 30, 2023 Period covered by this report: July 1, 2023 to December 31, 2023 WASTEWATER TREATMENT PLANT (POTW'S) NPDES PERMIT NUMBER City of Salisbury WWTP NCO023884 Person to contact concerning information contained in this report: NAME: Jeffery A Greer TITLE: Pretreatment Program Coordinator/ Interim Environmental Services Manager MAILING ADDRESS: 1915 GRUBB FERRY ROAD SALISBURY, N.C. 28144-1248 TELEPHONE: (704) - 638-5375 / (704) 216-2729 Fax Number: (704) - 704-797-4025 I have personally examined and am familiar with the information submitted in this document and attachments. Based upon my inquiry of those individuals immediately responsible for obtaining the information reported herein, I believe that the submitted information is true, accurate, and complete. I am aware that there are significant penalties .ation. Pretreatment Program Coordinator TITLE Interim Environmental Services Manager TITLE Sa/isbury�R�wan City of Salisbury Pretreatment Program Chain of Command February 9, 2024 Karen Alexander Mayor Brooks, Pierce, McLendon, Humphrey & Leonard Environmental Counsel Jim Greene, Jr. City Manager Jim Behmer Utilities Director Jeffery A Greer Interim Environmental Services Manager/ Pretreatment Program Coordinator Casey Banks Lab Services Supervisor Johnny Rogers FOG Program Coordinator Christina Molnar Regulatory Compliance Technician Savanah Snyder Lab Analyst Pretreatment Program Contact: Jeffery Greer 1915 Grubb Ferry Road Salisbury, North Carolina 28144 (704) 638- 5375- office (704) 216-2729 — desk (704) 797-4025 FAX Pretreatment Performance Summary (PPS) 1. Pretreatment Town Name: City of Salisbury 2. 'Primary" NPDES Number NCO023884 or Non Discharge Permit # if applicable => 3. PAR Begin Date, please enter 01/01/yyyy 3. => 01/01/2023 4. PAR End Date, please enter 12/31/yyyy 4. => 12/31/2023 5. Total number of SIUs, includes CIUs 5. => 6 6. Number of CIUs 6. => 2 7. Number of SIUs with no IUP, or with an expired IUP 7. => 0 8. Number of SIUs not inspected by POTW 8. => 0 9. Number of SIUs not sampled by POTW 9. => 0 10. Number of SIUs in SNC due to IUP Limit violations 10. => 0 11. Number of SIUs in SNC due to Reporting violations 11. => 0 12. Number of SIUs in SNC due to violation of a Compliance Schedule, CO, AO or similar 12. => 0 13. Number of CIUs in SNC 13. => 0 14. Number of SIUs included in Public Notice 14. => 0 15 Total number of SIUs on a compliance schedule, CO, AO or similar 15. => 0 16. Number of NOVs, NNCs or similar assesed to SIUs 16. => 1 1 17. Number of Civil Penalties assessed to SIUs 17. => 1 18. Number of Criminal Penalties assessed to SIUs 18. => 0 19. Total Amount of Civil Penalties Collected 19. => $ 4,000.00 20. Number of IUs from which penalties collected 20. => 1 votes: AO Administrative Order IUP Industrial User Pretreatment Permit POTW CIU Categorical Industrial User NNC Notice of Non -Compliance SIU Publicly Owned Treatment Works Significant Industrial User CO Consent Order NOV Notice of Violation SNC Significant Non -Compliance IU Industrial User PAR Pretreatment Annual Report revised 1 /2018: PAR PPS 2018 Sa/isb�ryR�wa� General Information for City of Salisbury WWTP (Grant Creek Treatment Train and Town Creek Treatment Train) January — December 2023 City of Salisbury WWTP consists of two treatment trains. Effluents from the Grant Creek and Town Creek treatment trains are disinfected at each train then combined and dechlorinated at the Yadkin Effluent treatment train, which is located downstream of Grant Creek treatment train before being discharged at Outfall 001 into the Yadkin River. Chlorine is primary disinfection followed by dechlorination. Design flow of the Grant Creek Treatment Train is 7.5 MGD, Town Creek Treatment Train is 5.0 MGD and the City of Salisbury WWTP is permitted at 12.5 MGD. The Headworks Analyses for Grant Creek and Town Creek Treatment Trains were approved on February 22, 2018. Currently, the updated Headworks Analysis has been submitted to DWR. DWR has acknowledged receipt on September 20, 2022. The Industrial Waste Survey for both treatment trains was conducted in 2019 and approved by DEQ on December 10, 2019. The Long -Term Monitoring plan was approved by DEQ on June 22, 2022. Note: A revised LTMP dated February 8, 2024 has been submitted to the State for approval. The revision includes the following: 1) Drop Hitachi Metals from the list of industries discharging to POTW 2) Updated parameter Oil and Grease as now a sampled parameter for our Uncontrollable Sites. The Sewer Use Ordinance was approved by PERCS on January 10, 2013 and adopted by City Council on August 20, 2013. PERCS approved the Enforcement Response Plan on June 17, 2013 and adopted by City Council on August 20, 2013. Pretreatment Program Info Database printed on: 12/22/2023 for Program Name Salisbury WWTP Name Grant Creek 'rogram Approval Date 10/07/1983 Pretreatment Status Full Region MRO County Rowan Stream Information IWC % at 7Q10 5.27 7010 Flow cfs / mgd 208.79 / 134.88 1Q10 Flow cfs / mgd 169.55 / 109.58 Stream Classification WS-V Basin Number YAD04 Receiving Stream Name YADKIN RIVER NPDES Number NCO023884 L Last PAR Rec 02/16/2023 PAR Due Date03/01/2024 mercury NPDES Effective Date q 4- 1,i` kv 1631 NPDES Expire Date p �� yCurrent Fiscal 0 it!61202Q- 1 I��I Zv %' `� required I.�IU' Year PCI Done POTW is Primary WWTP TRUE Last Audit on 08/09/2021 Audit Year NeA25/26 Design Flow mgd 7.5000 %Design mgd is SIU permitted Q 4 Permitted SIU flow (mgd) [Pt SIU) 1$ � l q WWTP SIU's Program SIUs "°'+ 16, ;c ° A IP WWTP CIU's Program CIUs HWA LTMP IWS SUO ER— date Inactive Date Next Due 11/01/2026 Date Received by DWR 09/20/2022 04/11/2022 09/17/2019 01/03/2013 05/06/2013 Date Approved 06/22/2022 12/10/2019 01/10/2013 06/17/2013 Adopt Date Required Date Adopted 08/20/2013 .A- /,,,, '. Pretreatment Related NOVs from DWQ DWR Central Office Contact lPretreatment Staff DWR Regional Contact es Bell City of Salisbury City of Salisbury WWTP NPDES NC0023884 Long Term Monitoring Plan Revised April 1, 2022 Sampling Points and Frequencies: Salisbury has a unique situation in that we have two Treatment Trains at two separate physical locations that the SIU's discharge into. The chlorinated effluent from the Town Creek Treatment Train (TE) is combined with the Grant Creek Treatment Train chlorinated effluent (GE). The combined chlorinated effluents (YE) join together on the Grant Creek property are dechlorinated, then flow through cascade aeration, and then discharge into the Yadkin River. Although not permitted as separate WWTPs, Town Creek and Grant Creek Treatment Trains will be treated as separate WWTPs in the LTMP with data from both sites used to determine pollutant removal efficiencies and plant inhibition thresholds. All SIUs and Locals are monitored per IU Permit requirements and all POC's once per year. The City uses a Yearly Monitoring Plan. The Plan is followed as closely as possible weather permitting. If an SIU is not monitored in the month indicated, it is monitored as soon as possible. Uncontrollables are composite and/or grab samples at points in the collection system that serves residential, commercial (including dentists and other medical), and any unpermitted non-SIUs. Uncontrollable sampling, though not required, will be monitored annually. Salisbury will use the actual sludge that is disposed of as our sludge sampling requirement per our sludge disposal permit (WQ0001956) and EPA 503 regs. Grant Treatment Train GR — Grant Influent (sampled post preliminary processes, prior to residual side streams and primary process). GE — Grant Effluent (sampled at end of chlorine contact basin) GAB — Grant Aeration Basin (sampled prior to influent of secondary clarification, due to accessibility) GS - Grant Sludge to Disposal (digester sludge to disposal, sludge taken at end of belt press) Town Treatment Train TR — Town Influent (sampled post preliminary processes, prior to residual side streams) TE — Town Effluent (sampled at end of chlorine contact basin) TAB 1 — Town Aeration Basin # 1 (sampled at effluent end of aeration basin) TAB2 — Town Aeration Basin#2 (sampled at effluent end of aeration basin) TS - Town Sludge to Disposal ( digester sludge to disposal, sludge taken at end of belt press) Final Effluent (Yadkin Effluent) YE — Grant and Town Creek Treatment Trains chlorinated combined effluents are dechlorinated then composite sampled prior to the cascade. Industries - Discharae to Grant & Town Creek Treatment Train FRE — Freirich Foods (Grant) HIT — Hitachi Metals (Grant) HXA — Hexagon Agility (Town) IPC — Innospec Performance Chemicals (Grant) NRN — Nouryon Surface Chemistry (Grant) TJN — Teijin automotive Technologies (Grant) TIIR — Thorneburg Hosiery Mills, Inc. (Town) Local SIUs and Uncontrollables PCA — Packing Corporation of America (Local permit) SPO — SupplyOne (Local permit) CHG- China Grove (Satellite -uncontrollable) LDS- Landis (Satellite -uncontrollable) GRQ- Granite Quarry (Satellite -uncontrollable) FAI- Faith (Satellite -uncontrollable) ESP -East Spencer (Satellite -uncontrollable) SPR-Spencer (Satellite -uncontrollable) Grant Creek Treatment Train Sam ling Points and Fre ncy Sample Location Sample ID Description Sample Type Sample Frequency Grant Influent GR Influent from collection 24 Hr Composite system, sampled post GR and GE sampled preliminary processes, quarterly on a prior to residual side workday and per streams and primary NPDES requirement process GAB samples Grant Aeration GAB Effluent from aeration Grab Basin basin, sampled prior to collected once every influent of secondary 6 months. clarification, due to accessibility Grant Effluent GE Effluent from treatment 24 Hr Composite train, sampled at end of chlorine contact basin Grant Sludge to GS Digester sludge to Grab GS samples collected Disposal disposal, sludge taken at per sludge permit end of belt press WQ0001956 and 503 regulations Page 2 Town Creek Treatment Train Sam ling Points and Fre uenc Sample Location Sample ID Description Sample Type Sample Frequency Town Influent TR Influent from collection 24 Hr Composite system, sampled post TR and TE sampled preliminary processes, quarterly on a prior to residual side workday and per streams NPDES requirement Town Aeration TAB 1 & Effluent from aeration Grab Basin TAB 2 basins, sampled TAB 1 & 2 samples separately at the effluent collected once every end of each aeration 6 months. basin Town Effluent TE Effluent from treatment 24 Hr Composite train, sampled at end of chlorine contact basin Town Sludge to TS Digester sludge to Grab TS samples collected Disposal disposal, sludge taken at per sludge permit end of belt press WQ0001956 and 503 regulations City of Salisbury WWTP Sampling Point and Frequency Code Name Description Type Frequency YE Combined Grant and Town Creek 24 hr composite sampled quarterly on Effluent Treatment a workday and per Trains dechlorinated NPDES requirement combined effluents Note: Dechlorinated combined effluent YE (TE + GE = YE) will be analyzed for each of the POCs but will not be used in the calculation of pollutant removal efficiencies, plant inhibition thresholds or in the calculation of uncontrollable loadings. Pollutants of Concern (POC): Reason for Inclusion Page 3 POC List NPDES 503 Sludge SIU Permit Limit Flow X X X BOD X X COD X TSS X X NH3-N X X NO2+NO3 X TKN X X Total Phosphorus X X Total Cyanide X X Oil & Grease X % Solids X As X X Cd X X Cr X Cu X X Pb X X Hg X Mo X Ni X X Se X Ag X X Zn X X Chloride X Parameter Detection Limits: Pollutant *DL, mg/l Pollutant *DL, Mercury method 245.1 .0002 **Mercury method 1631E .001 Nitrite + Nitrate 0.5 Arsenic 2.0 **Oil & Grease 10 Cadmium 0.50 BOD 2 Lead 2.0 COD 20 Silver 1.0 TSS 2.5 Chromium 5 TKN 1.5 Copper 2.0 NH3-N 0.5 Molybdenum 10 Total Phosphorus 0.2 Nickel 2.0 % Solids 25 Zinc 10 Chloride 1.0 Selenium 1.0 Sulfate 2.0 **Total Cyanide 5.0 **Phenol .010 **Styrene 1.0 Aluminum 050 Barium 10 Antimony .010 Boron 50 * Detection Limits are typical but may vary with changes in sample matrix or analytical conditions. **All POCs are 24 hour composites with the exception of Cyanide, Oil & Grease, and Mercury (1631 E method), Phenol and Styrene which are grabs. Sampling Plan Page 4 0 o�acn a° c z b o a ., �,sNx����o acnz cD ... c -, a a �o +x�000 0 o o a 61m Z Z Z CA C7 Cl A� a CD 0 fD 0 0 X X X k k X X k X X X X X X r• 0 0 fD fA 0 r+ r+ fD GRANT CREEK WASTEWATER TREATMENT TRAIN 1 Plant lnflentm 2 Prelknina ry Treatment 3 Main LM Iaatn 11%et / ffVV 4 Main Lg 2-8 pass® S PrimaryClar6* IA ielI'll 6 Primary Clarft &cessm 7 Trickling Filter Int / Eflm B Manhole No. 4 lnflentm 9 Aerates islnki./fl.® 10 Final Clarify kfl-tMM 11 Fin al Clarife gfletMM 12 Chlorine Contact Tank Inf. 13 EfOot P pi ng 5ta. BBe0I✓m 14 Final Clarify MS)® 15 Waste Actwted 9idaeM Feet 0 40 80 160 `') TOWN CREEK WASTEWATER TREATMENT TRAIN PIPING BACKUP POWER SUPPLY t��tH INFLUENT NO BACKUP POWER ------ —s ---4 DRAIN GENERATOR 1 ►----*----1-----► RAS GENERATOR 7 EFFLUENT GENERATOR 1 1=� WAS Treatment Unit 1 Prmary Treatment Influent 2 Primary Treatment Effluent 3 Man Lift Station Influent 4 Aeration Basin Influent 5 Final Clarifier Inlluant 6 Final Clarifier Effluent 7 Ctlorine Contact Tank Influent 8 Effluent Pump Station Influent 9 Effluent Pump Station Effluent 10 ReturnActivated Sludge 11 Waste Sludge Design Flow Average Daly (MGD) Flow (MGD) 50 2.096 5.0 2.161 5.0 2. 161 5.0 3.034 5.0 2.161 2.5 1.085 5.0 2.161 5.0 2.161 5.0 2. 161 5.0 0.864 0.07 0.045 AERATION BASIN g CLARIFIER CREW STATION S t AERATION BASIN 4 j NLORINE CON 11 eAsw DIGESTER Feet 0 40 80 160 EFFLUENT TO YADKIN RIVER Generator iviolet X GRANT AND TOWN CREEK EFFLUENTS COMBINED Cascade Post Aerator SALISBURY ROWAN WWTP YADKIN EFFLUENT (YE) Salisburyw�► {� 1 inch = 30 feet POTW=: NPDES*=: IUP Count 2 3 4 5 6 7 8 9 10 Workbook Name : Grant Creek HWA A i z018_Approved., Worksheet Name: AT Printed: 1/29/2024, ._._4 PM Page 1 of 4 Allocation Table Headworks last approved 02/22/18 Allocation Table updated: 02/01 /23 Permits last modified: 10/22/22 Grant Creek WWTT NCO023884 Spreadsheet Instructions: t) Applicable Values should be entered in the Heavy Bordered cells. Rest of worksheet is protected, password is "2". 2) Formulas are discussed in the Comprehensive Guidance, Chapter 6, Section C. 3) HWA and AT worksheets in this workbook are linked. Pollutant Names, MAHLs, Basis, and Uncontrollable load in this AT worksheet are automatically entered from the HWA spreadsheet. This includes pollutant names in columns AT through BK. Type Renewal Modification Date Pipe of Effective Effective Permit number Industry Date Date Expires Industry INDUSTRY NAMES Permit (please list alphabetich) number FLOW Permit Limits BOD Permit Limits TSS Permit Limits MGDgal/day Conc. Load m I Ibs/da Conc. Load m I lbs/da Nouryon 0002 01 2869-414 09/01/19 04/25/22 08/31/24 0.3830 383.000 300.00 500.00 Tie'in Automotive Technologies 0036 01 3089-463 09/30/19 10/22/22 09/29/24 0.0638 63.800 213.00 213.00 Freirich Foods 0007 01 2013 03/30/21 04/25/22 03/29/26 0.1500 150,000 1520.00 500.00 Innos ec Active Chemicals 0038 01 2843 10/01/22 09/30/27 0.0800 80,000 943.00 86.00 Column Totals => 0.67681 676.800 2976 1299 Basis=> MAHL from HWA (Ibs/day) => NPDES Permitted Flow— Uncontrollable Loading (lbs/day) => Total Allowable for Industry (MAIL) (lbs/day) => Total Permitted to Industry (Ibs/day) _> MAIL left (Ibs/day) => Percent Allow. Ind. (MAIL) still available (%) => Percent MAHL still available (%) => 5 Percent MAHL (lbs/dav) => NPDES Design Design 7.5000 20829 20204 5.2390 10923 10923 2.2610 9905.8 9280 0.6768 2976 1299 1.5842 6930 7981 70.1 % 70.0 % 86.0 % 21.1 % 33.3 % 39.5 0.3750 1041 1010 HWA.AT Revised: November 2005 POTW= NPDES = IUP Count 2 3 4 5 6 7 8 9 10 Workbook Name : Grant Creek_HWA A 11018_Approved., Worksheet Name: AT Printed: 1/29/2024, ._._4 PM Page 2 of 4 Allnratinn Tahle Headworks last approved Allocation Table updated: Permits last modified: 02/22/18 Pipe number 02/01/23 10/22/22 Grant Creek WWTT NCO023884 Industry INDUSTRY NAMES Permit (prase fist alphabetich) number Ammonia Permit Limits Arsenic Permit Limits Cadmium Permit Limits Chromium Permit Limits Copper Permit Limits Cyanide Permit Limits Cone. Load mg/1 lbs/day Cone. Load mgjl lbs/da Cone. Load m I Ibs/da Cone. Load mg/1 lbs/da Conc. Load mg/1 lbs/da Cone. Load mg/1 lbs/da Nouryon 0002 01 219.00 699.53 0.1500 0.0800 0.4200 Tie'in Automotive Technologies 0036 01 15.70 0.0950 Freirich Foods 0007 01 Innos ec Active Chemicals 0038 01 0.0050 0.0080 0.0250 0.0100 0.0067 Column Totals => 715 1 0.0000 0.0050 0.15801 1 0.2000 1 0.4267 Basis- MAHL from HWA (lbs/day) => Uncontrollable Loading (lbs/day) => Total Allowable for Industry (MAIL) (Ibs/day) _> Total Permitted to Industry (Ibs/day) => MAIL left (lbs/day) => Percent Allow. Ind. (MAIL) still available (%) => Percent MAHL still available (%) => 5 Percent MAHL (Ibs/dav) => NPDES 6946.28 1243.07 5703.21 715.23 4987.97 87.5 % 71.8 % 347.31 AS/NitITF inhibition 4.6193 0.1879 4.4314 0.0000 4.4314 100.0 % 95.9 % 0.2310 Stream Std 2.1293 0.1311 1.9982 0.0050 1.9932 99.7 % 93.6 % 0.1065 AS/Nit/TF inhibition 18.1999 2.1847 16.0153 0.1580 15.8573 99.0 % 87.1 % 0.9100 AS/Nit/TF inhibition 22.1725 3.0192 19.1533 0.2000 18.9533 99.0 % 85.5 % 1.1086 AS/NitITF inhibition 4.6193 1.7914 2.8279 0.4267 2.4012 84.9 52.0 0.2310 HWA.AT Revised: November 2005 POTW NPDES#= IUP Count 2 3 4 5 6 7 8 9 10 Workbook Name : Grant Creek_HWA A 1 &018 Approved., Worksheet Name: AT Printed: 1/29/2024, ._...4 PM Page 3 of 4 Allocatinn Table I Headworks last approved Allocation Table updated: Permits last modified: 02/22/18 Pipe number 02/01/23 10/22/22 Grant Creek WWTT NCO023884 Industry INDUSTRY NAMES Pen -nit (p)casc list alphabetich) number Lead Permit Limits Mercury Permit Limits Molybdenum Permit Limits Nickel Permit Limits Selenium Permit Limits Silver Permit Limits Cone. Load m /l Ibs/da Cone. Load ma/1 lbs/da Cone. Load mg/1 lbs/da Cone. Load m lbs/da Cone. Load m /1 Ibs/da Cone. Load m 1 Ibs/da Nouryon 0002 01 0.1000 0.1600 Tie'in Automotive Technologies 0036 01 Freirich Foods 0007 01 Innos ec Active Chemicals 0038 01 0.0050 0.0150 Column Totals => 0.1050 1 0.000000 0.0000 0.1750 0.0000 0.0000 Stream Sludge AS/Nit/TF Sludge Stream Basis=> Std Stream Std Ceiling inhibition Ceiling Std MAHL from HWA (lbs/day) => 9.3087 0.035133 35.1949 11.5482 8.4280 0.2811 Uncontrollable Loading (Ibs/day) => 2.1410 0.013108 4.6053 0.9176 0.1879 0.2185 Total Allowable for Industry (MAIL) (Ibs/day) => 7.1677 0.022025 30.5896 10.6306 8.2401 0.0626 Total Permitted to Industry (Ibs/day) => 0.1050 0.000000 0.0000 0.1750 0.0000 0.0000 MAIL left (lbs/day) => 7.0627 0.022025 30.5896 10.4556 8.2401 0.0626 Percent Allow. Ind. (MAIL) still available (%) => 98.5 % 100.0 % 100.0 % 100.0 °/O 100.0Percent MAHL still available (%) => 75.9% 62.7 % 86.9% k098.44 97.8% 22.35 Percent MAHL (Ibs/day) => 0.4654 0.001757 1.7597 0.4214 0.0141 HWA.AT Revised: November 2005 POTW= NPDESS= IUP Count 2 3 4 5 6 7 8 9 10 Workbook Name: Grant Creek_HWA A i cOl8_Approved., Worksheet Name: AT Printed: 1/29/2024, ._._4 PM Page 4 of 4 Allnratinn Tahla Headworks last approved Allocation Table updated: Permits last modified: 02/22/18 Pipe number 02/01/23 10/22/22 Grant Creek WWTT NCO023884 Industry INDUSTRY NAMES Permit (plcasc list alphabeticly) number Zinc Permit Limits Total Nitrogen Permit Limits Total Phos. Permit Limits Cone. Load m I lbs/da Cone. Load m /I lbs/da Cone. Load m I lbs/da Nouryon 0002 01 0.4250 130.00 Tie'in Automotive Technologies_ 0036 01 0.1900 Freirich Foods 0007 01 Innos ec Active Chemicals 0038 01 0.5000 Column Totals => 1 1.1150 0.00 130.00 AS/NitITF Basis=> inhibkion MAHL from HWA (Ibs/day) => 46.1928 Uncontrollable Loading (lbs/day) => 9.0969 ####### 334.25 Total Allowable for Industry (MAIL) (lbs/day) => 37.0958 Total Permitted to Industry (lbs/day) => 1.1150 0.00 130.00 MAIL left (Ibs/day) => 35.9808 Percent Allow. Ind. (MAIL) still available (%) => ####### ####### Percent MAHL still available (%) => M2.3096 ####### ####### 5 Percent MAHL (Ibs/dav) => HWA.AT Revised: November 2005 Pretreatment Annual Report (PAR) PAR covers this calendar year => January -December 2023 Significant Non -Compliance Report (SNCR) Control Authority, Town Name => City of Salisbury WWTP Name => City of Salisbury WWTP WWTP = Wastewater Treatment Plant, use separate for for each WWTP. Treatment Train => Grant Creek SIU = Significant Industrial User NPDES # => NCO023884 SNC = Significant Non -Compliance A SNCR FORM must submitted with every PAR, please write "None" if you had No SIUs in SNC during calendar year IUP # # Pipe # Industry Name Parameter or "Reporting" SNC ?(Yes/No) for each 6 - month period. Jan. -June July - Dec. NONE EVERY SNC MUST be explained in the Narrative, How was, is, or will it be resolved? REPEAT SNCs are serious matters that MUST be explained in the Narrative. Nouryon Surface Chemistry, LLC IUP # 0002 Jan - Jun and Jul- Dec 2023 Monitoring Period: SNC: None Orders: None Authorization to Construct: One An Authorization to Construct request was received on October 26, 2020 and approved by the City of Salisbury on October 28, 2020 for the construction of a Groundwater Pretreatment System Unit. UPDATE 2023: This Construction is nearing completion and has a projected start-up for Spring/Summer 2024. Missed Data: None Permit Reporting Violations Jan -June: None Permit limit violations Jan -June: None Penalty Assessed Jan- June: None Permit Reporting Violations July -December: None Permit limit violations July -December: None Penalty Assessed July- Dec: None The IUP expiration date is August 31, 2024. A Pretreatment Permit Application was sent to Nouryon on December 1, 2023 which is due to our office for review by June 1, 2024. Nouryon (NRN) continues to be responsible for the Industrial Pretreatment Permit compliance for the site. A service agreement between Nouryon and Henkel delineates the maintenance, operational, and monitoring responsibilities. Nouryon continues to provide the wastewater pretreatment service for the tenant operations, Indopco, Inc. (Henkel). Nouryon is a categorical industrial user that manufactures ingredients used in the personal care industry. Henkel Corporation manufactures adhesives used in the electronics industry. Pretreaiment Annual Report (PAR) Industrial Data Summary Form (IDSF) Use separate forms for each industry/pipe nter BDL values as <(value) Total # of samples => Maximum (mg/1) => or Maximum (lb/d) => or 6 month 1 /2 BDL Average (mg/1) => or Average Loading (lb/d) _> % violations, (chronic SNC is > 66%) _> % TRC violations, (SNC is > 33%) _> Total # of samples = Maximum (mg/1) => or Maximum (lb/d) _ or 6 month 112 BDL Average (mg/1) _ or Average Loading (lb/d) _ • violations, (chronic SNC is >=66%) _ • TRC violations, (SNC is > 33%) _ Total # of samples => Maximum (mg/1) => or Maximum (lb/d) => or 6 month 1 /2 BDL Average (mg/1) => or Average Loading (lb/d) => • violations, (chronic SNC is > 66%) => • TRC violations, (SNC is >=33%) => Control Authority, Town Name=> City of Salisbury WWTP Name => Salisbury -Rowan WWTP Treatment Train => Grant Creek NPDES # => NCO023884 1st6 months, dates => January 1, 2023-June 30, 2023 2nd 6 months, dates => July 1,2023-December 31,2023 Industry Name Nouryon Surface Chemistry IUP # 0002 Pipe # 01 Flow, mgd BOD TSS Ammonia 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1st 6 months 2nd 6 months 181 183 3 4 5 5 3 4 0.284800 0.244600 13.2 44.9 69.5 101.34 161.96 158.62 0.172502 0.12512 1 4.75 13.99 47.3 39.97 131.7 111.5 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% COD TKN Chromium Copper 1 st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 5 5 5 5 3 4 3 4 2050.5 1445.22 76.2 36.2 0.0615 0.0679 0.01248 0.02608 1350.0 1044.8 41.7 29.30 0.0444 0.0513 0.0081 0.0168 0,00% 0.0% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 1 0,00% 0.00% Nickel Phosphorus Sulfate Cyanide 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 3 4 3 4 3 4 3 4 0.0341 0.0554 10.5 27.58 4392.81 5419.58 0.0049 0.0053 0.0255 0.0417 8.45 14.9 2832.58 3651.42 0.0045 0.0042 0.00% 0,00% 0.00% 0.00% N/A N/A 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% N/A N/A 0.00% 0.00% POTW must enter at least one of these four rows, BDL => Below Detection Limit mg/I => milligrams liter Please indicate how averages were calculated Avg period IUP => Industrial User Permit Ib/d => pounds per day could be month, Qtr, or 6-month & if BDL, 1/2 BDL, or zero SNC => Significant Non -Compliance mgd => millions gallons per day values used. TRC => Technical Review Criteria WWTP => wastewater treatment plant Page 1 of 2 Total # of samples = Maximum (mg/1) => or Maximum (lb/d) _ or 6 month 1/2 BDL Average (mg/1) _ or Average Loading (lb/d) _ • violations, (chronic SNC is >=66%) _ • TRC violations, (SNC is >=33%) _ Total # of samples => Maximum (mg/1) _> or Maximum (lb/d) _ or 6 month 1/2 BDL Average (mg/1) _> or Average Loading (lb/d) _ • violations, (chronic SNC is > 66%) _> • TRC violations. (SNC is > 33%) _> Total # of samples => Maximum (mg/1) _> or Maximum (lb/d) _ or 6 month 112 BDL Average (mg/1) _ or Average Loading (lb/d) _ • violations, (chronic SNC is >=66%) _ • TRC violations, (SNC is > 33%) _ Industry Name: Nouryon Surface Chemistry IUP # 0002 Pipe # 01 Cyanide(MonthlyAvg.) Lead Lead (Monthly Avg.) Zinc 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 3 3 3 4 3 3 3 4 0.0049 0.0046 0.00158 0.00282 0.00158 0.00282 0.1157 0.3305 0.0045 0.0041 0,00116 0.00187 0.00116 0.0021 0,0783 0.164 0.00% 0.00% 0.00% 0,00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 1 0.00% 0.00% 0.00% 0.00% 0.00% Zinc (Monthly Avg.) Selenium Silver Nitrate & Nitrite 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 3 3 1 2 1 2 3 4 0.0025 0,0013 0.0005 0.0005 83.6 75.7 0.1157 0.3305 0.0025 0.0011 0.0005 0.00035 48.2 49.9 0.0783 0.1846 0.00% 0.00% N/A N/A N/A N/A N/A N/A 0.00% OM% N/A N/A N/A N/A N/A N/A pH, std units Temperature Chloride 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 186 189 186 189 3 4 8.70 9.30 26 30.2 165.51 371.88 ---- ---- 19.5 21.4 149.7 241.6 0.00% 0.00% 0.00% 0.00% N/A N/A 0.00% 0.00% 0.00% 0.00% N/A N/A < POTVV must enter at least one of these four rows, Please indicate how averages were calculated Avg period could be month, Qtr, or 6-month & if BDL, 1/2 BDL, or zero values used. BDL => Below Detection Limit mg/I => milligrams liter IUP => Industrial User Permit Ib/d => pounds per day SNC => Significant Non -Compliance mgd => millions gallons per day TRC => Technical Review Criteria VVVVTP => wastewater treatment plant Page 2 of 2 Teijin Automotive Technologies PERMIT #0036 Jan — Jun and Jul- Dec 2023 Monitoring Period: SNC: None Orders: None Missed Data: None Authorization to Construct 2023: None Notice of Non -Compliance Jan- June 2023-None Permit Reporting Violations 2023: One • Late submittal of the March 2023 Wastewater flow report (0.5 point assessed). Permit limit violations Jan -June 2023: TWO • Permit limit exceedance for parameter Zinc during 1/25/2023 City - monitoring sampling event • Permit limit exceedance for parameter COD during 3/16/2023 Self - monitoring. Points assessed Jan- June 20210.5 point Penalties assessed Jan- June 2023: None Notice of Non -Compliance July -December 2023: One Notice of Non -Compliance issued for failure to monitor daily parameters pH and Temperature at the permitted sampling point Pipe # 01 of permit # 0036. Teijin (TJN) reported a pH process exceedance of more than 10.00 s.u. that occurred on 10/20/2023, 11/4/2023, 11/5/2023 and 11/6/2023. The City of Salisbury Pretreatment Department (City) acknowledges that Teijin Automotive Technologies historically have not had any pH exceedances and that the facility staff closely monitor the pH on their processes due to customer product tight tolerance demands. In addition, the City had requested that the process (production and paint areas) wastewater pH be reported for process monitoring purposes and this may have caused a misunderstanding of where to sample daily pH and temperature. Follow-up investigation conducted by TJN discovered that all the past reported daily pH and Temperature readings have been taken from their process and not at the designated sampling site Pipe # 01. Based on investigation findings and past compliance, the City has determined that the pH data in question were not representative of the entire facility (process and domestic wastewater combined) and cannot be considered an effluent pH limit violation of permit #0036. Please note, Teijin staff began reading daily pH and Temperature at their permitted sampling point (Pipe # 01) on 11/14/ 2023. Permit limit violations July -December 2023: None Permit Reporting violations July- December: One • Late submittal of the September 2023 Wastewater flow report (0.5 point assessed) Points assessed July -December- 0.5 point Penalties assessed July -December: None Penalties assessed are in accordance to the City of Salisbury's Enforcement Response Plan. Points accumulated during the July -December 2022 reporting period were 8.5 points which required a monetary fine assessment of $4000.00. The penalty was sent to IU on January 18, 2023 with a due date of February 17, 2023. IU received the penalty on January 26, 2023 and collection was pending at time of the 2022 PAR report. 2023 UPDATE: Payment collection for Penalty was received, per City of Salisbury Finance, on February 15, 2023. IUP expiration date is September 29, 2024. A Pretreatment Permit Application was sent to Teijin Automotive Technologies on January 2, 2024, which is due to our office for review by June 30, 2024. Teijin Automotive Technologies manufactures fiberglass exterior parts for the large truck and golf cart industries. Pretre_-..._nt Annual Report (PAR) Industrial Data Summary Form (IDSF) Use separate forms for each industry/pipe Enter 13DL values as <(value) Total # of samples => Maximum (mg/1) => or Maximum (lb/d) _ or 6 Months using BDL Average (mg/1) _ or Average Loading (lb/d) _ % violations. (chronic SNC is > 66%) _ % TRC violations, (SNC is > 33%) _ Total # of samples => Maximum (mg/1) => or Maximum (lb/d) => or 6 Months using BDL Average (mg/1) => or Average Loading (lb/d) => % violations, (chronic SNC is > 66%) => % TRC violations, (SNC is >=33%) => Total # of samples = Maximum (mg/1) => or Maximum (lb/d) _ or 6 Months using BDL Average (mg/1) _ or Average Loading (lb/d) _ % violations, (chronic SNC is >=66%) _ % TRC violations, (SNC is > 33%) _ Control Authority, Industry Town Name => City of Salisbury Name: Teijin Automotive Technologies WWTP Name => Salisbury -Rowan WWTP luP # 0036 Treatment Train => Grant Creek Pipe # 01 NPDES # => NCO023884 1st6 months, dates=> January 1,2023-June 30,2023 2nd 6 months, dates => July 1, 2023-December 31,2023 Flow, mgd BOD TSS TKN 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 181 184 4 3 5 5 5 5 0,050300 0.046800 169.9 56.87 67.85 28.24 12.92 13.55 0.032046 0.020097 116.0 41.8 27.89 13.9 9.56 7.17 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0%. 0.0% COD Ammonia Nitrogen Copper Zinc 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 6 5 4 3 4 3 5 3 791.75 489.08 4.06 6.69 0.00776 0.00376 0.2159 0.0636 325.37 227.30 2.17 4.21 0.0049 0.0031 0.1144 0.0428 16.7% 0.0% 0.0% 0.0% 0.0% 0.0% 20.0% 0.0% 16.7% 0.0% 0.0% 0.0% 0.0% 0.0% 1 0.0% 0.0% Oil & Grease pH, std units Temperature Phosphorus 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 2 3 187 189 187 189 2 3 9.89 18.3 9.95 10.79 36.11 37.6 6.0 1 6.17 11.26 ----- ----- 27.5 27.3 3.7 0.92 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% N/A N/A 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% N/A N/A POTW must enter at least one of these four rows. BDL => Below Detection Limit mg/I => milligrams liter Please indicate how averages were calculated Avg period IUP => Industrial User Permit Ib/d => pounds per day could be month. Qtr, or 6-month & if BDL. 1/2 BDL, or zero SNC => Significant Non -Compliance mgd => millions gallons per day values used. TRC => Technical Review Criteria WWTP => wastewater treatment plant Page 1 of 2 Total # of samples => Maximum (mg/1) _> or Maximum (lb/d) _> or 6 Months using BDL Average (mg/1) _> or Average Loading (lb/d) _> % violations. (chronic SNC is > 66%) _> % TRC violations, (SNC is > 33%) _> Total # of samples => Maximum (mg/1) => or Maximum (lb/d) _> or 6 Months using BDL Average (mg/1) _> or Average Loading (lb/d) _> % violations, (chronic SNC is > 66%) _> % TRC violations, (SNC is > 33%) _> Total # of samples Maximum (mg/I) or Maximum (lb/d) or 6 Months using BDL Average (mg/1) or Average Loading (lb/d) % violations, (chronic SNC is > 66%) % TRC violations, (SNC is > 33%) Industry Name: Teijin Automotive Technologies IUP # 0036 Pipe # 01 Styrene 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 2 0 0.0025 0.00175 N/A N/A N/A N/A 1 st 6 months 12nd 6 months 11 st 6 months 12nd 6 months 11 st 6 months 12nd 6 months 11 st 6 months 12nd 6 months 1 st 6 months 12nd 6 months 11 st 6 months 12nd 6 months 11 st 6 months 12nd 6 months 11 st 6 months 12nd 6 months < POTW must enter at least one of these four rows, Please indicate how averages were calculated Avg period could be month, Qtr, or 6-month & if BDL, 112 BDL, or zero values used. BDL => Below Detection Limit mg/I => milligrams liter IUP => Industrial User Permit Ib/d => pounds per day SNC => Significant Non -Compliance mgd => millions gallons per day TRC => Technical Review Criteria WWTP => wastewater treatment plant Page 2 of 2 FREIRICH FOODS PERMIT #0007 Jan - Jun and Jul- Dec 2023 Monitoring Period: SNC: None Orders: None Authorization to Construct: None Missed Data: None Notice of Non -Compliance (NNC) January -December 2023: None Permit limit violations Jan -June: None Permit reporting violations Jan -June: None Penalties assessed Jan -June: None Permit limit violations July -December: One (3 points were assessed) Failure to notify the City of Salisbury Environmental Services within 24 hours of becoming aware of a violation as stated in Freirich Foods Industrial User Permit Part II General Conditions Section 2 (b). The following daily pH reading entries were found to be non -compliant upon City review on the July 2023 wastewater flow report submittal received on 8/8/2023: July 1st, July 2nd, July 15th, July 24th, July 25th and July 31st. The Parameter listed below was found to be in VIOLATION of the Discharge Permit Limitations for your facility on the dates indicated. Date Parameter Results (s.u.) Permit Limit (s.u.) % Over Limit 7/1/23 pH (Self) 5.53 6.00-10.00 7.8% 7/2/23 pH (Self) 5.92 6.00-10.00 1.3% 7/15/23 pH (Self) 5.88 6.00-10.00 2.0% 7/24/23 pH (Self) 5.98 6.00-10.00 .33% 7/25/23 pH (Self) 5.7 6.00-10.00 5.0% 7/31/23 pH (Self) 5.98 6.00-10.00 .33% Permit reporting violations July -December: TWO 1) Late Submittal of the July 2023 wastewater flow report (0.5 Points assessed) 2) Failure to Self- monitor for the month of July, per permitted 2/6 monitoring frequency (2 points were assessed). Penalties assessed July -December 2023: 5.5 points Penalties assessed are in accordance to the City of Salisbury's Enforcement Response Plan. Points accumulated during the July -December 2023 reporting period were 5.5 points which required a monetary fine assessment of $1000.00. The penalty was sent to IU on January 2, 2024 with a due date of February 1, 2024. IU permit expiration date is March 29, 2026. Freirich Foods is a meat processing plant. Total # of samples => Maximum (mg/1) => or Maximum (lb/d) _> or 6 month using 1 /2 BDL Average(mg/1) _> or Average Loading (lb/d) _ • violations, (chronic SNC is >=66%) _> • TRC violations, (SNC is > 33%) _> Total # of samples = Maximum (mg/I) => or Maximum (lb/d) _ or 6 month using 1 /2 BDL Average(mg/1) _ or Average Loading (lb/d) _ • violations, (chronic SNC is >=66%) _ • TRC violations, (SNC is > 33%) _ Total # of samples => Maximum (mg/1) => or Maximum (lb/d) _ or 6 month using 1 /2 BDL Average(mg/1) _> or Average Loading (lb/d) _ • violations,(chronic SNC is > 66%) _> • TRC violations, (SNC is >=33%) _ Control Authority, lqw Town Name => City of Salisbury WWTPName=> Salibury-Rowan WWTP Treatment Train => Grant Creek NPDES # => NCO023884 1st 6 months, dates => January 1,2023-June 30,2023 2nd 6 months, dates => July 1, 2023-December 31, 2023 Industry Name Freirich Foods IUP # 0007 Pipe # 01 Flow, mgd BOD TSS Oil & Grease 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 179 183 3 2 4 4 3 2 0.113800 0.131400 17.5 5.7 1235.8 921.5 282.0 198.2 0,045521 0.042758 1 7.50 4.1 700.8 723.9 161.9 141.00 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% COD TKN Chloride pH, std units 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 4 4 4 4 3 2 185 188 9.67 9.93 1890.6 1378.6 135.3 88.6 1349.1 1016.4 1260.3 1113.5 89.92 67.1 718.6 751.5 0.0% 0.0 0 0.0% 0.0% 0.0% 0.0% 3.2% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% Temperature Phosphorus Molybdenum Total Zinc 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 185 188 3 2 3 2 3 2 35.3 36.9 131 92.3 0.0204 0.0363 0.502 0.394 19.9 24.2 74.9 91.1 0.0163 0.02065 0.372 0.354 0.0% 0.0% N/A N/A N/A N/A N/A N/A 0.0% 0.0% N/A N/A N/A N/A N/A N/A POTW must enter at least one of these four rows, Please indicate how averages were calculated Avg period could be month, Qtr, or 6-month & if BDL, 1/2 BDL, or zero values used. BDL => Below Detection Limit mg/I => milligrams liter IUP => Industrial User Permit Ib/d => pounds per day SNC => Significant Non -Compliance mgd => millions gallons per day TRC => Technical Review Criteria WWTP => wastewater treatment plant Page 1 of 1 INNOSPEC ACTIVE CHEMICALS PERMIT #0038 Jan - Jun and Jul- Dec 2023 Monitoring Period: SNC: None Orders: None Missed Data: None Notice of Non-compliance January- December 2023: None Authorization to Construct 2023: TWO 1) An Authorization to Construct (A to C) request was received on March 22, 2023 by Salisbury - Rowan Utilities from Innospec Active Chemicals (IPC). The request included the installation of the following equipment: A Multi -Disc Screw Sludge Press, an 8,000-gallon sludge storage tank with agitator, a polymer/feed system and a staging area for a roll off box dumpster. The system will be enclosed in a new 20' X 20' contained building to be located to the West of the current Dissolved Air Flotation building. City approval for this A to C was given on March 27, 2023. Note: All Construction has been completed and operational (per this A to C) since October 2023. 2) An Authorization to Construct (A to C) request was received on June 29, 2023 by Salisbury - Rowan Utilities from Innospec Active Chemicals (IPC). The request included the installation of the following equipment: Reactors # R-22, # R-23, and # R-28. City approval for this A to C was given on June 30, 2023.Note: Reactor #R-28 was brought on-line and operating in November 2023. Permit Reporting violations January- June: None Permit Limits Violations January- June: One Notice of Violation issued for permit limit exceedance for parameter Cyanide during IU's 1/12/23 self -monitoring sampling event. Penalties Jan -June: None Permit Reporting violations July- December: ONE A Notice of violation was issued November 1, 2023 per the late submittal of the September 2023 IDMR. Permit Limits Violations July- December: One A Notice of Violation was issued November 28, 2023 for a permit exceedance for parameter TKN during a 11/2/23 City -monitoring sampling event. Penalties July- December: None Updated Authorization to Construct granted 2021: TWO 1. IPC requested an Authorization to Construct (A to C) on March 23, 2021 for an Expansion Plan Project -Phase 1. The request included the installation of the following equipment: Three new reactors (#15, #16, and # 17); two new Flaker Units (#4 and # 5) and Flaker feed tanks; and a new vacuum system. All the Expansion Plan Project proposed equipment was City approved for construction on April 7, 2021. Also included in this A to C request was an increase in IPC's Zinc parameter Permit Limits from 0.5 pounds/day to 0.75 pounds/day. The City denied this Zinc increase request, due in part to insufficient data to support the request. UPDATE 2023: Reactors # 15, # 16, and #17 are now on-line. Flaker Unit # 4 is up and running. At the time of this report-- Flaker Unit #5 is approximately projected to start in June 2024. 2. An A to C request was received on July 9, 2021 for IPC's Expansion Plan Project- Phase 2. The request included the installation of the following equipment: Four new reactors (# 18, #19, #20 and #21), associated Vacuum System and Ancillary equipment of condensers, receivers, and a hot oil heater. Also, in the request was the manufacture of two new products using a new product line process. Authorization was granted and approved by the City for this A to C on July 15, 2021. UPDATE 2023: Reactors # 18, #19 are now operating and on-line. At time of this report-- Reactor # 20 is approximately projected to start in June 2024. Reactor #21 is projected to been operation in February 2024. The two new products using new product line process are now being manufactured. The IUP expires September 30, 2027. This SIU manufactures surfactants and emollients for the personal care industry. 2 'retre nt Annual Report (PAR) ndustrial Data Summary Form (IDSF) Jse separate forms for each industry/pipe nter BDL values as <(value) Total # of samples => Maximum (mg/1) => or Maximum (lb/d) => or 6 month using BDL Average (mg/1) => or Average Loading (lb/d) => • violations,(chronic SNC is >=66%) => • TRC violations, (SNC is > 33%) => Total # of samples => Maximum (mg/1) => or Maximum (lb/d) _ or 6 month using BDL Average (mg/1) _ or Average Loading (lb/d) _ % violations, (chronic SNC is > 66%) => % TRC violations, (SNC is >=33%) => Total # of samples => Maximum (mg/1) => or Maximum (lb/d) _ or 6 month using BDL Average (mg/1) _ or Average Loading (lb/d) _ % violations, (chronic SNC is >=66%) _> % TRC violations, (SNC is > 33%) _ Control Authority, Industry Town Name => City of Salisbury Name WWTP Name => Salisbury -Rowan WWTP luP # Treatment Train => Grant Creek Pipe # NPDES # => NCO023884 1st 6 months, dates => January 1, 2023 - June 30, 2023 end 6 months, dates =>July 1, 2023-December 31, 2023 Innospec Active Chemicals 0038 01 Flow, mgd BOD TSS COD 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 181 180 3 4 5 5 5 5 0.080000 0.080000 442.4 177.3 59.74 15.59 917.4 466.01 0.048049 0.050798 259.5 111.80 21.1 7.25 561.3 307.3 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% TKN Ammonia Nitrogen Chloride Cyanide 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 4 5 1 2 1 2 3 3 1.34 3.12 557.0 740.0 0.012 0.004 7.37 17.99 1.34 1.585 557.0 642.5 0.009 0.003 3.09 5.69 0.0% 20.0% N/A N/A N/A N/A 33.3% 0.0% 0.0% 0.0% N/A N/A N/A N/A 0.0% 0.0% NO2 + NO3 Phosphorus Aluminum Cadmium 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 2 3 1 2 1 2 2 3 0.0274 0.6856 0.2464 0.32329 1.26 2.27 0.00004 0.00013 0.02192 0.32345 0.2464 0.26575 1.26 1.31 0.00003 0.00006 N/A N/A N/A N/A N/A N/A 0.0% 0.0% N/A N/A N/A N/A N/A N/A 0.0% 0.0% POTW must enter at least one of these four rows, BDL => Below Detection Limit mg/I => milligrams liter Please indicate how averages were calculated Avg period IUP => Industrial User Permit Ib/d => pounds per day could be month, Qtr, or 6-month & if BDL, 1 /2 BDL, or zero SNC => Significant Non -Compliance mgd => millions gallons per day values used. TRC => Technical Review Criteria WWTP => wastewater treatment plant Page 1 of 2 Total # of samples = Maximum (mg/1) _> or Maximum (lb/d) _ or 6 month using BDL Average (mg/1) _ or Average Loading (lb/d) _ • violations, (chronic SNC is >=66%) _ • TRC violations, (SNC is >=33%) _ Total # of samples = Maximum (mg/1) _> or Maximum (lb/d) _ or 6 month using BDL Average (mg/1) _ or Average Loading (lb/d) _ % violations, (chronic SNC is >=66%) _ % TRC violations, (SNC is > 33%) Total # of samples Maximum (mg/1) or Maximum (lb/d) or 6 month using BDL Average (mg/1) or Average Loading (lb/d) % violations,(chronic SNC is > 66%) % TRC violations, (SNC is >=33%) in u us try Name Innospec Active Chemicals IUP # 0038 Pipe # 01 Chromium Copper Lead Nickel 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 2 2 3 1 2 2 3 0.00164 0.00027 0,00384 0.0032 0.000082 0.000269 0.01129 0.00754 0.00164 0.00026 0.0029 0.00223 0.000082 0.000259 0.0062 0.00652 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 1 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% Phenols Zinc pH, std units Temperature 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st-6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 2 2 3 187 186 187 186 0.692 0.680 7.42 7.55 24.9 28.9 0.32119 0,04068 0.692 0.540 ---- ---- 16.9 19.1 0.2114 0.0289 N/A N/A 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% N/A N/A 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 1 st 6 months 12nd 6 months 11 st 6 months 12nd 6 months 11 st 6 months 12nd 6 months 11 st 6 months 12nd 6 months < POTW must enter at least one of these four rows, Please indicate how averages were calculated Avg period could be month, Qtr, or 6-month & if BDL, 1/2 BDL, or zero values used. BDL => Below Detection Limit mg/I => milligrams liter IUP => Industrial User Permit Ib/d => pounds per day SNC => Significant Non -Compliance mgd => millions gallons per day TRC => Technical Review Criteria WWTP => wastewater treatment plant Page 2 of 2 Pretreatment Program Info Database printed on: 12/22/2023 for Program Name Salisbury WWTP Name Town Creek Program Approval Date 10/07/1983 Pretreatment Status Full Region MRO County Rowan Stream Information IWC % at 7Q10 5.27 7Q10 Flow cfs / mgd 139.20 / 89.92 1 Q10 Flow cfs / mgd 113.36 / 73.26 Stream Classification WS-V Basin Number YAD04 Receiving Stream Name YADKIN RIVER NPDES Number NC0023884 ,fast PAR Rec 02/16/2023 PAR Due Date03/01/2024 mercury NPDES Effective Date fig+- '7I1';t�� 1631 Current Fiscal required NPDES Expire Date p6f3g�" %�3���r' �� Year PC[ Donee 6 f �91 tG�i q POTW is Primary WWTP FALSE Last Audit on 08/09/2021 Audit Year Next25/26 Design Flow mgd 5.0000 % Design mgd is SIU permitted ®4 Permitted SIU flow (mgd) [Pt—SIU) WWTP SIU's Program SIUs WWTP CIU's 1 Program CIUsHWA LTMP IWS SUo ERP date Inactive Date Next Due 11/01/2026 Date Received by DWR 09/20/2022 02/06/2021 09/17/2019 01/03/2013 05/06/2013 Date Approved Adopt Date Required Date Adopted 11/04/2021 12/10/2019 01/10/2013 06/17/2013 08/20/2013'��»I Info in this Box from Pt Contacts PT Pro Formal Name g.Prime Phone1 Date Attended ext Fax HWA Wksp Date Attended IUP Wksp Date Attended PAR Wksp r. Jeffery Greer Prim (704) 216-2729 04-797-4025 11 1/23/2018 1 5/17/2016 1/29/2019 jyree@salisburync.gov Pretreatment Program Coordinator 11915 Grubb Ferry Road 8144 05('r(0N VA-(,lrlll�j Environmental Services Manager H 04-797-4025 11 Mr. Mark Monroe (764) - S. fi1 a. 7e'F 2 L -j.-73jj Regulatory Compliance Technician Mr. Johnny Rogers I 1�04-216-7568 I VO4-797-4025 II 101/22/2018 F.O.G. Program Coordinator DWR Central Office Contact JPretreatment Staff DWR Regional Contact Fes Bell SQL POTW NPDES#= IUP Count 2 3 4 5 6 7 8 9 10 Workbook Name: Town Creek HWA A !018_Approved., Worksheet Name: AT Printed: 1/29/20: , )3 PM Page 1 of 4 Allocation Table Headworks last approved 02/22/18 Allocation Table updated: 04/25/22 Permits last modified: 04/25/22 Town Creek WWTT NCO023884 Industry INDUSTRY NAMES Permit (Pieass,list eipnebeech) number Spreadsheet Instructions: 1) Applicable Values should be entered in the Heavy Bordered cells. Rest of worksheet is protected, password is'7'. 2) Formulas are discussed in the Comprehensive Guidance, Chapter 6, Section C. 3) HWA and AT worksheets in this workbook are linked. Pollutant Names, MAHLs, Basis, and Uncontrollable load in this AT worksheet are automatically entered from the HWA spreadsheet. This includes pollutant names in columns AT through BK. Type Renewal Modification Date Pipe of Effective Effective Permit number Industry Date Date Expires FLOW Permit Limits BOD Permit Limits TSS Permit Limits MGDgal/day Conc. Load m I lbs/da Conc. Load m /l lbs/da Hexagon Agility 0039 01 3714-433 01/01/22 12/31/27 0.0350 35.000 Tholmeburg Hosiery Mills, Inc. 0034 01 2252 11/01/21 04/25/22 10/31/26 0.1000 250.00 250.00 Column Totals => L 0.13501 35,000 250 250 Basis=> MAHL from HWA (lbs/day) => NPDES Permitted Flow=> Uncontrollable Loading (lbs/day) => Total Allowable for Industry (MAIL) (Ibs/day) => Total Permitted to Industry (lbs/day) => MAIL left (lbs/day) => Percent Allow. Ind. (MAIL) still available (%) => Percent MAHL still available (%) => 5 Percent MAHL (Ibs/dav) => NPDES Design Design 5.0000 14595 16680 2.1603 4504 5009 2.8397 10090.8 11671 0.1350 250 250 2.7047 9841 11421 95.2 % 97.5 % 97.9 % 54.1 % 67.4 % 68.5 0.2500 730 834 HWA.AT Revised: November 2005 POTA NPDES= IUP Count 2 3 4 5 6 7 8 9 10 Workbook Name: Town Creek_HWA AT 2018_Approved., Worksheet Name: AT Printed: 1/29/2024, 1:03 PM Page 2 of 4 Allocation Table Headworks last approved 02/22/18 Allocation Table updated: 04/25/22 Permits last modified: 04/25/22 Town Creek WWTT NCO023884 Industry INDUSTRY NAMES Permit (please list alphabeticly) number Pipe number Ammonia Permit Limits Arsenic Permit Limits Cadmium Permit Limits Chromium Permit Limits Copper Permit Limits Cyanide Permit Limits Conc. Load m /I lbs/da Conc. Load m 1 lbs/da Conc. Load Mg/1 lbs/da Conc. Load Mg/1 Ibs/da Conc. Load m l lbs/da Conc. Load m /1 lbs/da Hexagon Agility 0039 01 0.0700 0.0204 1.7100 0.4991 2.0700 0.6042 0.6500 0.1897 Thomeburg Hosiery Mills, Inc. 0034 01 0.0510 Column Totals => 0 0.0 000 0.0204 0.4991 0.6552 0.1897 AS/Nit/TF AS/Nit/TF Stream AS/Nit/TF AS/Nit(TF AS/Nit/TF Basis=> inhibition inhibition Std inhibition inhibition inhibition MAHL from HWA (Ibs/day) => 8859.08 1.8456 1.3971 7.2718 8.8591 1.8456 Uncontrollable Loading (lbs/day) => 450.42 0.0775 0.0541 0.9008 1.0990 0.7387 Total Allowable for Industry (MAIL) (lbs/day) => 8408.66 1.7682 1.3430 6.3710 7.7601 1.1069 Total Permitted to Industry (lbs/day) => 0.00 0.0000 0.0204 0.4991 0.6552 0.1897 MAIL left (lbs/day) => 8408.66 1.7682 1.3226 5.8719 7.1049 0.9172 Percent Allow. Ind. (MAIL) still available (%) => 100.0 % 100.0 % 98.5 % 92.2 % 91.6 % 82.9 % Percent MAHL still available (%) => 94.9 % 95.8 % 94.7 % 80.7 % 80.2 % 49.7 % 5 Percent MAHL Obs/dav) => 442.95 0.0923 0.0699 0.3636 0.4430 0.0923 HWA.AT Revised: November 2005 POTW=: NPDES#= IUP Count 2 3 4 5 6 7 8 9 10 Workbook Name: Town Creek_HWA A 1 2018 Approved., Worksheet Name: AT Printed: 1/29/202-, ..J3 PM Page 3 of 4 Alloratinn Table I Headworks last approved 02/22/18 Allocation Table updated: 04/25/22 Permits last modified: 04/25/22 Town Creek WWTT NCO023884 Industry INDUSTRY NAMES Permit (please list alphabcticic) number Pipe number Lead Permit Limits Mercury Permit Limits Molybdenum Permit Limits Nickel Permit Limits Selenium Permit Limits Silver Permit Limits Conc. Load av Conc. Load MRVI lbs/da Conc. Load m I lbs/day Conc. Load mgA lbs/day Conc. Load MO lbs/da Conc. Load MR/1 lbs/da Hexagon Agility 0039 01 0.4300 0.1255 2.3800 0.6947 0.2400 0.0701 Thomeburg Hosiery Mills, Inc. 0034 01 Column Totals => 0.1255 0.000000 0.00001 0.0000 0.0701 Stream Sludge AS/Nit/TF Basis=> Std Stream Std Ceiling inhibition MAHL from HWA (lbs/day) => 6.1077 0.023052 4.3853 4.6141 Uncontrollable Loading (lbs/day) => 0.8828 0.005405 0.0901 0.3784 Total Allowable for Industry (MAIL) (lbs/day) => 5.2249 0.017647 4.2952 4.2358 Total Permitted to Industry (lbs/day) => 0.1255 0.000000 0.0000 0.6947 MAIL left (lbs/day) => 5.0994 0.017647 4.2952 3.5411 Percent Allow. Ind. (MAIL) still available (%) _> 97.6 % 100.0 % 100.0 % 83.6 % Percent MAHL still available (%) => 83.5 % 76.6 % 97.9 % 76.7 5 Percent MAHL (lbs/dav) _> 0.3054 0.001153 0.2193 0.2307 HWA.AT Revised: November 2005 Sludge Stream Ceiling Std 3.8591 0.1844 0.0775 0.0901 3.7816 0.0943 0.0000 0.0701 3.7816 0.0242 100.0 % 25.7 98.0 % 13.1 0.1930 0.0092 POTW=: NPDES#=: IUP Count 2 3 4 5 6 7 8 9 10 Workbook Name: Town Creek_HWA AT 2018_Approved., Worksheet Name: AT Printed: 1/29/2024, -i:U3 PM Page 4 of 4 Allnratinn Table Headworks last approved 02/22/18 Allocation Table updated: 04/25/22 Permits last modified: 04/25/22 Town Creek WWTT NCO023884 Industry INDUSTRY NAMES Permit (please list alphabetich) number Pipe number Zinc Permit Limits Total Nitrogen Permit Limits Total Phos. Permit Limits Conc. Load ay Conc. Load mg/1 Ibs/da Conc. Load m /I Ibs/da Hexagon Agility 0039 01 1.4800 0.4320 Thorneburg Hosiery Mills, Inc. 0034 01 0.1460 Column Totals => 0.5780 0.00 0.00 AS/Nlt/TF Basis=> inhibition MAHL from HWA (lbs/day) => 18.4564 Uncontrollable Loading (lbs/day) => 3.1530 653.6352 96.93 Total Allowable for Industry (MAIL) (lbs/day) => 15.3035 Total Permitted to Industry (lbs/day) => 0.5780 0.00 0.00 MAIL left (lbs/day) => 14.7255 Percent Allow. Ind. (MAIL) still available (%) => #######Percent MAHL still available (%) => M6. #######5 Percent MAHL Obs/dav) => HWA.AT Revised: November 2005 Pretreatment Annual Report (PAR) PAR covers this calendar year => January -December 2023 Significant Non -Compliance Report (SNCR) Control Authority, Town Name => City of Salisbury WWTP Name => City of Salisbury WWTP WWTP = Wastewater Treatment Plant, use separate for for each WWTP. Treatment Train => Town Creek SIU = Significant Industrial User NPDES # => NCO023884 SNC = Significant Non -Compliance A SNCR FORM must submitted with every PAR, please write "None" if you had No SIUs in SNC during calendar year IUP # # Pipe # Industry Name Parameter or "Reporting" SNC ? (Yes /No) for each 6 - month period. Jan. -June July - Dec. NONE EVERY SNC MUST be explained in the Narrative, How was, is, or will it be resolved? REPEAT SNCs are serious matters that MUST be explained in the Narrative. HEXAGON AGILITY, Inc. PERMIT #0039 Jan - Jun and Jul- Dec 2023 Monitoring Period: SNC: None Orders: None Missed Data: None Permit limit violations Jan -June: None Reporting Violations Jan -June: None Permit limit violations July -December: None Reporting Violations July -December: None Notice of Non -Compliance (NNC) January- December: None Authorization to Construct (A to C): One Hexagon Agility requested an A to C on September 29, 2022 for a 118,000 square foot expansion addition to its existing facility. The addition will be used for the manufacturing and testing of Composite Overwrapped Pressure Vessels. The City of Salisbury Pretreatment approved this A to C on November 28, 2022 for the following equipment: An oil and water separator to serve 2 air compressors, a solids separator, an oil and sand separator and a sample port for sampling. Hexagon was instructed upon final construction to submit laboratory analysis of the wastewater discharge generated from the 118,000 to determine if any adjustments/modifications will be needed to their current Industrial User Pretreatment Permit. UPDATE 2023: Construction of the 118,000 square foot building addition should be completed in the first quarter of 2024, and then the installation of production equipment will begin. Hexagon Agility manufactures, paints, assembles, packages, ships and installs compressed natural gas fuel systems for commercial trucks. Categorical Industrial User 40 CFR 433.17 IU Permit expiration date is December 31, 2027. Hexagon Agility has been in good standing since first Pretreatment Permit issued January 2017 maintaining perfect compliance. Pretre mt Annual Report (PAR) Industrial Data Summary Form (IDSF) Use separate forms for each industry/pipe Enter BDL values as <(value) Total # of samples = Maximum (mg/1) => or Maximum (lb/d) _ or 6 month using BDL Average (mg/1) _ or Average Loading (lb/d) _ % violations, (chronic SNC is > 66%) _ • TRC violations, (SNC is > 33%) _ Total # of samples = Maximum (mg/1) => or Maximum (lb/d) _ or 6 month using BDL Average (mg/1) _ or Average Loading (lb/d) _ % violations, (chronic SNC is > 66%) _ % TRC violations, (SNC is > 33%) _ Total # of samples = Maximum (mg/1) => or Maximum (lb/d) = or 6 month using BDL Average (mg/1) = or Average Loading (lb/d) _ % violations, (chronic SNC is > 66%) _ % TRC violations, (SNC is > 33%) _ Control Authority, Town Name => City of Salisbury WWTP Name => Salibury-Rowan WWTP Treatment Train => Town Creek NPDES # => NCO023884 1st 6 months, dates => January 1 ,2023-June 30, 2023 2nd 6 months, dates => July 1, 2023-December 31, 2023 Industry Name Hexagon Agility IuP # 0039 Pipe # 01 Flow, mgd Cadmiun Chromium Copper 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 164 163 3 2 3 2 3 2 0.023295 0.020222 0.0001 0.00005 0.0028 0.0005 0.004 0.0040 0.014105 0.009391 0.000067 0.00005 0.0013 0.0005 0.0032 0.0039 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% Cyanide Lead Nickel Silver 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 3 2 3 2 3 2 3 2 0.004 0.0025 0.0005 0.0005 0.002 0.0005 0.00025 0.00025 0.003 0.0025 0.0005 0.0005 0.0012 0.0005 0.0002 0.00025 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% Zinc pH, std units Temperature Aluminum 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 3 2 168 165 168 165 3 2 0.0242 0.0177 8.50 8.09 32.1 30.6 0.852 0.401 0.01237 0.0114 ---- ---- 23.8 24.4 0.4917 0.345 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% N/A N/A 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% N/A N/A POTW must enter at least one of these four rows, BDL => Below Detection Limit mg/I => milligrams liter Please indicate how averages were calculated Avg period IUP => Industrial User Permit Ib/d => pounds per day could be month, Qtr, or 6-month & if BDL, 112 BDL, or zero SNC => Significant Non -Compliance mgd => millions gallons per day values used. TRC => Technical Review Criteria WWTP => wastewater treatment plant Page 1 of 2 Total # of samples => Maximum (mg/1) => or Maximum (lb/d) => or 6 month using BDL Average (mg/1) => or Average Loading (lb/d) => • violations, (chronic SNC is >=66%) => • TRC violations, (SNC is > 33%) => Total # of samples => Maximum (mg/1) => or Maximum (lb/d) => or 6 month using BDL Average (mg/1) => or Average Loading (lb/d) => % violations, (chronic SNC is > 66%) => % TRC violations, (SNC is > 33%) => Total # of samples => Maximum (mg/1) => or Maximum (lb/d) => or 6 month using BDL Average (mg/1) => or Average Loading (lb/d/106can) => % violations, (chronic SNC is > 66%) => % TRC violations, (SNC is > 33%) => Industry Name Hexagon Agility IuP # 0039 Pipe # 01 TTO* 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months *Certifies for TTO as Not Being Present 1 st 6 months 12nd 6 months 11 st 6 months 12nd 6 months 11 st 6 months 12nd 6 months 11 st 6 months 12nd 6 months 1 st 6 months 12nd 6 months 11 st 6 months 12nd 6 months 11 st 6 months 12nd 6 months 11 st 6 months 12nd 6 months < POTW must enter at least one of these four rows, Please indicate how averages were calculated Avg period could be month, Qtr, or 6-month & if BDL, 1/2 BDL, or zero values used. BDL => Below Detection Limit mg/I => milligrams liter IUP => Industrial User Permit Ib/d => pounds per day SNC => Significant Non -Compliance mgd => millions gallons per day TRC => Technical Review Criteria WWTP => wastewater treatment plant Page 2 of 2 THORNEBURG HOSIERY MILLS, INC. PERMIT #0034 Jan - Jun and Jul- Dec 2023 Monitoring Period: SNC: None Orders: None Authorization to Construct: None Missed Data: None Penalties: None Reporting Violations Jan -June: None Permit limit violations Jan -June: None Reporting Violations Jan -June: None Permit limit violations July -December: None The IUP expires on October 31, 2026. Thorneburg Hosiery Mills, Inc. is a textile industry that dyes, washes, and packages socks. 'retr( ?nt Annual Report (PAR) ndustrial Data Summary Form (IDSF) Jse separate forms for each industry/pipe Enter BDL values as <(value) Total # of samples = Maximum (mg/1) => or Maximum (lb/d) = or 6 month using BDL Average (mg/1) = or Average Loading (lb/d) _ • violations, (chronic SNC is > 66%) _ • TRC violations, (SNC is >=33%) _ Total # of samples => Maximum (mg/1) => or Maximum (lb/d) => or 6 month using BDL Average (mg/1) => or Average Loading (lb/d) => • violations, (chronic SNC is > 66%) => • TRC violations, (SNC is > 33%) => Total # of samples => Maximum (mg/1) => or Maximum (lb/d) _ or 6 month using BDL Average (mg/1) _> or Average Loading (lb/d) _ • violations, (chronic SNC is > 66%) _ • TRC violations, (SNC is >=33%) _ Control Authority, Town Name => City of Salisbury WWTP Name => Salisbury -Rowan WWTP Treatment Train => Town Creek NPDES # => NCO023892 1st 6 months, dates => January 1, 2023 - June 30, 2023 2nd 6 months, dates => July 1, 2023-December 31, 2023 Industry Name Thorneburg Hosiery Mills, Inc. IuP # 0034 Pipe # 01 Flow, mgd BOD TSS COD 1 st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 167 127 3 2 3 2 3 2 0.035327 0.028616 8.6 160.6 1.79 2.118 24.4 38.8 0.012400 0.012256 4.5 87.5 1.46 1.55 22.2 32.7 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% TKN Copper Chloride Temperature 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 3 2 3 2 2 1 99 97 47.5 43.5 0.793 0.74 0.0022 0.0015 2.43 2.8 32.5 34.3 0.57 0.64 0.0017 0.0014 1.97 2.8 0.0% 0.0% 0.0% 0.0% N/A N/A 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% N/A N/A 0.0% 0.0% Antimony Chromium Zinc pH, std units 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 3 1 3 1 3 2 99 97 9.58 9.78 0.0013 0.00008 0.0003 0.00024 0.0461 0.0453 0,00076 0.00008 0.00026 0.00024 0.0364 0.0384 N/A N/A N/A N/A 0.0% 0.0% 0.0% 0.0% N/A N/A N/A N/A 0.0% 0.0% 0.0% 0.0% POTW must enter at least one of these four rows. BDL => Below Detection Limit mg/I => milligrams liter Please indicate how averages were calculated Avg period IUP => Industrial User Permit Ib/d => pounds per day could be month, Qtr, or 6-month & if BDL, 1/2 BDL, or zero SNC => Significant Non -Compliance mgd => millions gallons per day (values used. TRC => Technical Review Criteria WWTP => wastewater treatment plant Page 1 of 1 GRANTS CREEK WASTEWATER TREATMENT TRAIN PIPING BACKUP POWER SUPPLY •+++ INFLUENT GENERATOR 1 DRAIN GENERATOR RAS GENERATOR 3 EFFLUENT NO POWER NEEDED �+ WAS Treatment Unit Design Flow (MGD) 1 Plant Influent 7.5 2 Preliminary Treatment 3.8 3 Main LiftStation Influent/Effluent 7.5 4 Main LiftStation Bypass 0 5 Primary Clarifier Influent 6.9 6 Primary Clarifier Excess 0.6 7 Equalization Basins 6.9 8 Manhole No. 4Influent 14.4 AERATION BASIN 9 Aeration Basin Influent/Effluent 15 10 Final Clarifier Influent 7.5 11 Final Clarifier Effluent 3.8 12 Chlorine Contact Tank Influent 7.5 13 Effluent Pumping Station Effluent 7.5 14 Final Clarifier(RAS) 3.8 15 RAS/WAS Pump Station !4 t RiDMarsETTuxc SECONDARY enSIN CLARIFIER /lx �1J EQUALIZATION 1 D C nks . Il wnrsErruxo y aeslx TANK#7 ., 13 O i SECONDARY II 1 T CLARIFIER 'FWMT WLb9TPn0 s 10 SE.,. IS 11 l J IEESTER EQUALIZATION Sl s TANK#2 DIGESTER#2 x SECONDARY CLARIFIER s DIGESTER##1 T \ ❑ �' V m` orEx noxs IS c O MOV DEGw 6 BYPASS SIDE SIREAM W O MI'MTI W MPSCREE4 `� 5 BBM9CflEEH ® Feet 0 2040 80 120 160 Map printed 2/14/24 TOWN CREEK WASTEWATER TREATMENT TRAIN PIPING BACKUP POWER SUPPLY ++� INFLUENT NO BACKUP POWER F—F DRAIN 0 GENERATOR 1 -ter--r RAS GENERATOR 2 EFFLUENT 0 GENERATOR WAS Treatment Unit Design S IER Flow (NIGD) 1 Primary Treatment Influent 5.0 2 Primary Treatment Effluent 5.0 (10 3 Main Lift Station Influent 5.0 CREW PUM 4 Aeration Basin Influent 5.0 STATION 5 Final Clarifier Influent 5.0 6 Final Clarifier Effluent 2.5 f�l i 6 7 Chlorine Contact Tank Influent 5.0 5 FIER 8 Effluent Pump Station Influent 5.0 9 Effluent Pump Station Effluent 5.0 3 4 10 Return Activated Sludge 5.0 11 Waste Sludge 0.07 11 7 CHLORINE T BASIN 11 DIGESTER cQ TANKS 8 EFFLUENT ❑ UMP STATI 9 SLUDGE PRESS II DIGESTER T ASTE PUMP 11TATN] -r z r �E P M TR NT v+ S r—. 111 ® Feet _. 0 20 40 80 120 160 Map printed 11/28/18 Treatment Unit Design Flow (MGD) 1 Parshall Flume 40.0 2 Dechlorinaton 40.0 EFFLUENT TO YADKIN RIVER 3 Cascade Aeration 40.0 GENERATOR CASCADE tL/ POSTAERATOR `•, DECHLOR TANKS ; 11 J X� \'O9 4S <iQG/Q yq4`F OFOy(O <v�� R GRANTANDTOWN CREEK EFFLUENTS COMBINED SALISBURY-ROWAN WWTP YADKIN EFFLUENT (YE) finch =30 feet w e /^ Map printed 2/13124 s