Loading...
HomeMy WebLinkAboutNC0066249_Compliance Evaluation Inspection_20230911 SENT VIA ELECTRONIC MAIL ONLY: NO HARDCOPY WILL BE MAILED September 11, 2023 Leisa Reusch 109 Redwater Way Greer, SC 29651 SUBJECT: Compliance Inspection Report Country Acres MHP WWTP NPDES WW Permit No. NC0066249 Henderson County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Country Acres MHP WWTP on 6/29/2023. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0066249. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". The solids level at the plant was undesirably high but it appears to be due to issues with pump truck schedules as opposed to negligence by the permittee. If you should have any questions, please do not hesitate to contact me at the Asheville Regional Office at 828-296-4500 or via email at daniel.boss@deq.nc.gov. Sincerely, Daniel Boss, Assistant Regional Supervisor Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Ec: Laserfiche, Jones Environmental DocuSign Envelope ID: 9AB25272-DBE0-4374-8159-E0942A6223EB EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NC0066249 23/06/29 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Country Acres MHP WWTP 25 Keith Memorial Dr Mills River NC 28759 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 10:00AM 23/06/29 21/10/01 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Mark Brandon Jones/ORC/828-273-0760/ Other Facility Data 12:00PM 23/06/29 25/11/30 Name, Address of Responsible Official/Title/Phone and Fax Number Leisa Reusch,109 Redwater Way Greer SC 29651//828-606-5823/Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Self-Monitoring Program Facility Site Review Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Rachel Rose DWR/ARO WQ/828-296-4500/ Daniel J Boss DWR/ARO WQ/828-296-4658/ Julia Byrd DWR/NPDES WW Permitting Unit/919-707-3607/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 DocuSign Envelope ID: 9AB25272-DBE0-4374-8159-E0942A6223EB 2/19/2024 2/19/2024 2/19/2024 NPDES yr/mo/day 23/06/29 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On 6/29/2023, Julia Byrd, Rachel Rose, and I (Daniel Boss) conducted a Compliance Evaluation Inspection of the Country Acres Mobile Home Park WWTP. We met with Mark Jones (ORC) for the inspection. The solids levels in the WWTP were undesirably high. Settled solids after 30 minutes were at about 95%. The sludge blanket in the clarifier was about 9 feet out of 12 feet of water depth.Mr. Jones prefers to keep the settled solids level at 65%, but he said the pump truck was behind schedule. Solids are pumped from the WWTP about once per month during the summer and every 3 months in the winter. Mr. Jones prefers to keep the settled solids level at 65%, but he said the pump truck was behind schedule. Solids are pumped from the WWTP about once per month during the summer and every 3 months in the winter. The clarifier had some floating solids from denitrification. Mr. Jones says the plant runs 30 minutes on/30 minutes off. This WWTP doesn't have a generator but the mobile home park uses a well water system which doesn't run during power outages. NC0066249 17 (Cont.) Page#2 DocuSign Envelope ID: 9AB25272-DBE0-4374-8159-E0942A6223EB Permit:NC0066249 Inspection Date:06/29/2023 Owner - Facility: Inspection Type: Country Acres MHP WWTP Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Settleable is solids checked every 2 weeks and DO is checked weekly.Comment: Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin’s surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/l) The DO in the aeration basin is typically 2 mg/L. The settled solids level at 30 min was 95%. Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Page#3 DocuSign Envelope ID: 9AB25272-DBE0-4374-8159-E0942A6223EB Permit:NC0066249 Inspection Date:06/29/2023 Owner - Facility: Inspection Type: Country Acres MHP WWTP Compliance Evaluation Secondary Clarifier Yes No NA NE Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately ¼ of the sidewall depth) There was a 9' sludge blanket out of 12' depth in the clarifier. There were floating solids on the surface of the clarifier from denitrification. Comment: Disinfection-Tablet Yes No NA NE Are tablet chlorinators operational? Are the tablets the proper size and type? Number of tubes in use?1 Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de-chlorination? Comment: De-chlorination Yes No NA NE Type of system ?Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de-chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de-chlorinators operational? Number of tubes in use?1 Comment: Pump Station - Effluent Yes No NA NE Is the pump wet well free of bypass lines or structures? Are all pumps present? Are all pumps operable? Are float controls operable? Page#4 DocuSign Envelope ID: 9AB25272-DBE0-4374-8159-E0942A6223EB Permit:NC0066249 Inspection Date:06/29/2023 Owner - Facility: Inspection Type: Country Acres MHP WWTP Compliance Evaluation Pump Station - Effluent Yes No NA NE Is SCADA telemetry available and operational? Is audible and visual alarm available and operational? There is no visual alarm.Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: Page#5 DocuSign Envelope ID: 9AB25272-DBE0-4374-8159-E0942A6223EB