Loading...
HomeMy WebLinkAbout820466_Digester Volume Calculation Update_20231220Facility Number: 82-0466 Grower: Goodson Farm Designed By: JEO Address: PO Box 856 Checked By: DSE Warsaw, NC 28398 Date: 10/16/23 County: Sampson Sheet 1 of 6 ANAEROBIC DIGESTER DESIGN Volume Check FARM INFORMATION Farm Population: Nursery: Wean to Finish: ------------------- 0 Finishing: ------------------- 20992 Hd. 25 Yr. / 24 Hr Storm Event Recycle Flush Water Volume: DIGESTER INFORMATION Is Digester Designed as an Irregular Shape? (Y/N) Was This Facility Built Prior to 9/96? (Y/N) Is Drain Tile Req'd to Lower SHWT? (Y/N) Seasonal High Water Table Elev: ------------------- Freeboard:------------------- Side Slopes: ------------------- From Lagoon Volume Check Contours contour areas see sheet 2 of 7... Top of Dike Elevation: ---------------- Depth Finished Bottom Elevation: ---------------- 12.00 Ft. Start Pump Elevation: ---------------- 20.04 In. Stop Pump Elevation: ---------------- 24 In. Top of Sludge Elevation: ---------------- 144 In. DIGESTER VOLUMES REQUIRED VOL. Storm Temp= 53819 (Cu.Ft.) Temporary = 0 (Cu.Ft.) Operational = 671744 (Cu.Ft.) Permanent Sludge = 0 (Cu.Ft.) Total Volume = 725,563 (Cu.Ft.) Lagoon Surface Area: (Inside TOD) DESIGN VOLUMES 57,505 (Cu.Ft.) 28,323 (Cu.Ft.) 651,125 (Cu.Ft.) 15,659 (Cu.Ft.) 752,612 (Cu.Ft.) Y N N LINK 7.0 In. 0 1.0 Ft. 3 :1 (H-.V) 430.0 Ft. 215.0 Ft. 113.00 Ft. 101.00 Ft. 111.33 Ft. 111.00 Ft. 101.00 Ft. % REQ'D. 106.85% 4.22% 96.93% 103.73% 92,261 S.F. Smithfield Hog Production Engineering P.O. Box 856 ,Warsaw, NC 26398 (910) 293-343, Facility Number: 82-046 Grower: Goodson Farm Address: PO Box 856 Warsaw, NC 28398 Countv: Sampson BASE VOLUME: Designed By: JEO Checked By: DSE Date: 10/16/23 Sheet 2 of 6 ACTUAL DESIGN VOLUME CALCULATIONS �Cu. Ft. DIGESTER STAGE -AREA VOLUMES Contour Elevation (FT.) Area (SF) Incr. Vol. +:Cu. FTi 101.00 40,517 102.00 52,789 103.00 55,678 104.00 58,646 105.00 61,693 106.00 64,818 107.00 68,195 108.00 71,855 109.00 75,687 110.00 79,644 111.00 83,725 112.00 87,931 113.00 92,261 46,653 54,233 57,162 60,169 63,255 66,507 70,025 73,771 77,665 81,684 85,828 90,096 Cumul. Vol. (Cu. FT 15,659 62,312 116,545 173,707 233,877 297,132 363,638 433,663 507,434 585,100 666,784 752,612 842,708 These volumes were calculated using the vertical average end area method. TOTAL REQD VOL 671,744 CF CUMULATIVE VOL. ZONE VOL. 0.00% END PUMP = = = = 111.00 FT 666,784 CF TR'MT 651,125 96.93% START PUMP = =: 111.33 FT 695,107 CF TEMP 28,323 4.22% MAX STORAGE = 112.00 FT 752,612 CF STORM 57,505 106.85% Smithfield Hog Production Engineering P.O. Box 856,Warsaw, NC 28398 (910) 293-3434 Grower: Goodson Farm Designed By: JEO Address: PO Box 856 Checked By: KBW Warsaw, NC 28398 Date: 10/16/23 Countv: Sampson Sheet 3 of 6 MINIMUM REQUIRED VOLUME CALCULATIONS DIGESTER Permanent Storage: Required Treatment Volume: Animal Type Capacity (cu.ft./hd) = Total Wean to Finish 0 32.00 0 Finishing 20,992 32.00 671,744 Farrow Farrow to 1.00 0.50 Total Required Treatment Volume (cu. ft.)= Sludge Storage Volume: 671,744 Animal Type Capacity ALW (cu.ft./lb) = Total Wean to Finish 0 115 0.00 0 Finishing 20,992 135 0.00 0 Farrow . feeder Total Required Sludge Storage Volume (cu. ft.)= No Storm Storage Unless a Partial Cover Digester: Vol.=(Digester Surf. Area + Addt'I Drainage Area) * 25Yr./24Hr. Storm(in) / 12in./ft. Vol.= (92261 sq.ft + 0 sq.ft.) * 7.0 in. /12 in./ft. Total Required Volume for 25Yr./24Hr. Storm Event (cu.ft)= No "Heavy Rain" Storage Unless a Partial Cover Digester: Vol.=(Digester Surf. Area + Addt'I Drainage Area) * "Heavy Rain" Factor (in) / 12in./ft. Vol.= (92261 sq.ft + 0 sq.ft.) * 0.0 in. /12 in./ft. Total Required Volume for "Heavy Rain" (cu.ft.) = (for Extended Periods of Chronic Rainfall) 0 53,819 Total Required Storm Storage (25Yr. / 24Hr. Storm +'Heavy Rain')= 53,819 (CU.FT) Total Required Permanent Storage (Treatment + Sludge) = 671,744 (CU.FT) TOTAL REQUIRED DIGESTER VOLUME = 725563 (CU.FT.) 0 Grower: Goodson Farm Designed By: JEO Address: PO Box 856 Checked By: KBW Warsaw, NC 28398 Date: 10/16/23 Countv: Sampson Sheet 4 of 6 DIGESTER DESIGN SUMMARY Top of Dike Elevation Top of 25Yr. / 24Hr. Storm Storage 113.00 FT. 112.00 FT. Start Pump Elevation ------------------- 111.33 FT. End Pump Elevation ------------------- 111.00 FT. Top of Sludge Storage ------------------- 101.00 FT. Seasonal High Watertable Elev.------------------- UNK Finished Bottom Elevation ------------------- 101.00 FT. Inside Top Length ------------------- Not Applicable Inside Top Width ------------------- Not Applicable Side Slopes ------------------- 3.0:1 H:V Lagoon Surface Area ------------------- 92,261 SF Freeboard Depth Zone Depths: TOTAL DESIGN VOLUME = 752612 (CU.FT.) Treatment / Sludge Storage Zone Depth Temporary Storage Zone Depth Freeboard Depth Total Digester Depth 1.00 FT, 10.0 FT. 0.3 FT. 1.7 FT. 12.0 FT M N O O i W m � Y O i o "-' � O I I (6 L E- m 2 U) O O C Y 2)U N O ` 0U o 0 �I O M M O O 00 II CDCh O O O W N II J C II Cl)II W U W II W --I > w LU J z LLJ w w W w w 2i O Y L 2 _O w O0 H w Q w o H W J n. O O c i o W O O O O = W U) O 00 O O Z N I- f- H �I LL 0 rn M 0 i M O u- Lo Z o 00 C o O O N Q O 0 II II m 0 CL U) LJU J W � L N m Ld C7 Q U U) W co 0) co N U Z i LO 00 O m Grower: Goodson Farm Address: PO Box 856 Warsaw, NC 28398 Cou Designed By: Checked By: Date: Sheet 6 of 6 JEO KBW 10/16/23 This Anerobic Digester is designed in accordance with the North Carolina Natural Resources Conservation Service PRACTICE STANDARD 366- ANEROBIC DIGESTER, revised in September, 2018. The Waste Storage Pond is designed in accordance with the North Carolina Natural Resources Convservation Service PRACTICE STANDARD 313- WASTE STORAGE FACILITY, revised in December, 2017. `SFPAF&AN11114c? DESIGNED: DATE: 11 /27/2023 COMMENTS: The lagoon has been designed as an irregular shape. accounted for and that storage volumes calculated represent actual conditions regardless of the shape. Effluent from the digester will be transferred to the existing lagoon treatment and sto l certify, to the best of my professional knowledge, judgement, and belief, this design calculation is in accordance with the applicable NRCS standards. Smithfield Hog Production Engineering P.O. Box 856, Warsaw NC 28398 (910) 293-3434